COMAC Property Services Office of Housing Department of Human Services 25th. Floor, 50 Lonsdale Street, Melbourne 3001 Tel: (03) 9096 5001 Fax: (03) 9096 9262 ROOMING HOUSE PROPERTY ASSESSMENT REPORT FOR: 41-43 JACKSON STREET, ST. KILDA. VIC. 3182. DATE: MAY 2009 PREPARED BY: DAN LUCIN BUILDING DESIGNERS PTY. LTD. P.O. BOX 1436. TULLAMARINE. VIC. 3043. Tel: (03) 9310 3556 Fax: (03) 9310 3384 Email: dlucin@bigpond.net.au 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 1.0 INDEX: 1.0 2.0 2.1.0 2.2.0 2.3.0 2.4.0 2.5.0 2.6.0 3.0 3.1.0 3.2.0 3.3.0 3.4.0 3.5.0 3.6.0 4.0 5.0 5.1.0 5.2.0 5.3.0 5.4.0 6.0 7.0 7.1.0 7.2.0 7.3.0 7.4.0 7.5.0 7.6.0 7.7.0 7.8.0 2.0 Rooming House Property Assessment Report COVER INDEX INTRODUCTION General Details Overview Business Rules Client Brief Consultant’s Comments Check List Legend MAIN BODY Structural Elements Site Elements Building External Building Internal Fixtures & Fittings Building & Site Services INDICATIVE COST SUMMARY ROOMING HOUSE STANDARDS Rooming House Standards Extract Compliance to Rooming House Standards Compliance to Building Code of Australia Planning Controls, Heritage Overlays & Register CONCLUSION APPENDICES Photographs Existing Condition Drawings Property Cost Assessment Form Room House Compliance Spreadsheet Room House Costing Spreadsheet Room House – Planning Controls Room House – Heritage Overlay Room House – Historic Building Register Page 1 2 2 2 3 3 3 3 3 4 4 4 7 10 13 15 17 18 18 19 19 19 20 21 22 28 29 30 31 32 33 34 INTRODUCTION: 2.1.0 GENERAL DETAILS: ADDRESS: TENANT: TENANT CONTACT No: COMMUNITY GROUP: CONTACT PERSON: CONTACT No: INSPECTION DATE: CURRENT USAGE: RISE IN STORIES: 531469465 41-43 Jackson Street, St. Kilda. Vic. 3182 Various NA St. Kilda Community Housing John Broderick (03) 9534 1809 February 2009 Boarding house (Occupied) 2 Page 2 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 2.2.0 Rooming House Property Assessment Report OVERVIEW: Roof: Windows: Ground Floor Structure: 1st Floor Structure: Construction Bedrooms: Corrugated Roofing Timber double hung Timber Structure (main) & Concrete Slab (lightcourt) Timber Structure Solid Brick 18no bed sitters The property at 41-43 Jackson Street, St. Kilda. Vic. 3182 is a two storey building consisting of x 18No. bed sitters located at the property, all of which are currently occupied. The property is located on the Southern side of Jackson Street. There has been an enclosed light court made to the rear of the building & there is car access to the rear of the property via a laneway. The original building is of solid brick construction with timber floors (ground & first floors), timber double hung windows, & corrugated sheet roofing. The rear light court area is on a concrete slab base, with aluminium fixed windows and aluminium framed glazed roofing. The external cosmetics appearance of the building was observed to be in reasonable condition with general maintenance required. Internally there are a total of 18No. bedsitters (9No. to the ground floor & 9No. to the first floor). There is a communal laundry, 2 stairways, cleaners cupboard, store & boiler room. Each of the 18No. Bedsitters contain a kitchenette, living/bed area, & bathroom. The overall internal conditions of the bedsitters & communal areas appear to be in reasonable condition, with carpet, paint & minor maintenance works required. 2.3.0 BUSINESS RULES The focus of this report is to provide possible options to address the issues discovered on site with consideration given to the Asset Development & Innovation (ADI) checklist, the Community Housing Standards, the Department of Human Services business rules & to the social environment & client group. 2.4.0 CLIENT BRIEF The client brief requested the property be investigated for maintenance and upgrade works in accordance with the Community Housing Standards & the Department of Human Services Business Rules. 2.5.0 CONSULTANTS COMMENTS The original building at this property is an old Victorian terrace style of building that although there it has had a fairly recent light court addition made to the rear of the property, any further additions may be affected by planning controls & heritage overlay requirements. Any modifications or repairs made to this front building will require further research to determine if any heritage requirements must be met. 2.6.0 CHECK LIST LEGEND: Denotes item has been checked & refer to clause for comment & breakdown Denotes not applicable item 531469465 Page 3 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. 3.0.0 MAIN BODY: 3.1.0 STRUCTURAL ELEMENTS No. 3.1.1 3.1.2 3.1.1 a) b 3.1.2 3.1.3 3.2.0 Checked Description Floors Walls No. 3.1.3 Checked Description Roofs Floors: Timber floors It was not possible to access the sub-floor area to determine the existing condition. The timber floors throughout the original two storey house were observed to be in reasonable to good condition, there was no evidence of movement with no bouncy & uneven floors in the house. Recommendation: Nil Concrete floors It was observed that the rear light court area unit area had a paving that appeared to be in good condition. Recommendation: Nil $ 0.00 $ 0.00 Walls It was observed that there are solid brick walls to the property. There appeared to be no significant surface cracking to the internal solid plastered walls of the property. Recommendation: Nil $ 0.00 Roofs It was not possible to access the roof space of the house to determine the existing condition. The roofing areas were visually inspected from ground level and they all appeared to have no indications that there were any structural problems with the roofing structures. Recommendation: Nil $ 0.00 SITE ELEMENTS No. 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.1 531469465 Checked Description Condition Paving Fencing Gates Carport Garage No. 3.2.7 3.2.8 3.2.9 3.2.10 3.2.11 3.2.12 Checked Description Garden Shed Steps/Ramp Clothesline Drainage Letterbox Landscaping Condition The general condition of the site is reasonable condition with minor maintenance required to several deteriorating features Recommendation: Nil Page 4 of 34 $ 0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.2.2 a) b) c) 3.2.3 a) b) c) d) 3.2.4 531469465 Rooming House Property Assessment Report Paving Front Yard There front yard area consists of a tiled front verandah area & concrete with brick border entrance pathway providing a continuous path of access from the front gate to the main entrance door threshold. All to these areas were observed to be in good condition. Recommendation: Nil Rear Yard It was observed that the rear yard area had concrete paved walkways together with grassed areas. The paving provides access leading from the rear doorway to the parking area & exit gate. All of the paving to this area appeared to be in good condition. Recommendation: Nil Driveway/ROW There was concrete paving to the rear carpark area all that was observed to be in good condition. The ROW was in poor condition and is either council owned or jointly owned with the neighboring property to the Western side. Recommendation: Nil Fencing Party Fencing It was observed that there was a timber paling party fence to the Eastern side boundary. This fence appeared to be in good condition. Recommendation: Nil Front Fencing There was an existing 1500mm high timber picket fence with pedestrian gate to the front boundary of this property. The front fence was observed to be in reasonable condition. The front & bin enclosure gates require servicing to ensure correct & proper operation. Some pickets are required to be replaced and entire fence is required to be painted. Recommendation: Undercut existing gates & rehang & repaint picket fencing complete together with appx. 20no. pickets to be replaced. Wing Fencing Timber picket fencing appx. 1500mm high generally in good order. Recommendation: Nil Rear Fencing There was an existing 1500mm high timber picket fence with 2no. pedestrian gates to the rear boundary of this property together with a painted timber paling fence to the Eastern party. The rear fence was observed to be in reasonable condition. Some pickets are required to be replaced and entire fences are required to be painted. Recommendation: Replace 3no. posts, repaint picket fencing complete together with appx. 25no. pickets to be replaced. Repaint party paling fence. Nil Gates Refer to fencing Recommendation: Nil $ 0.00 $ 0.00 $ 0.00 $ 0.00 $ 1,850.00 $ 0.00 $ 2,450.00 $ 0.00 $0.00 Page 5 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 3.2.10 a) b) 3.2.11 3.2.12 a) 531469465 Rooming House Property Assessment Report Carspaces It was observed that there is a concrete paved 3no carspace parking area at the end of the ROW. All was in order. Recommendation: Nil $0.00 Garage Nil Recommendation: Nil $0.00 Garden Shed Nil Recommendation: Supply & install a new garden shed on concrete base together with an extension to the existing concrete pathway. $ 1,600.00 Steps & Ramps All steps are in good order. Recommendation: Nil $0.00 Clothesline It was observed that there were 2No. paraline clotheslines to this property. Both located in the side yard adjacent to the common laundry and in good order. Recommendation: Nil $ 0.00 Drainage Storm water drainage system The storm water drainage system to this property was visually inspected from ground level where possible. There appeared to be no blockages & that the storm water system was operating as required. Recommendation: Nil Sewerage drainage system The sewerage system to this property was visually inspected at ground level where possible. There appeared to be no blockages to the sewerage system & it was operating as required. Recommendation: Nil $ 0.00 $ 0.00 Letterbox It was observed that there was a freestanding metal powder coated bank of letterboxes located at the front of the property next to the path leading to the front door. It appeared to be securely fixed & in good condition. Recommendation: Nil $ 0.00 Landscaping Lawns Lawn areas were in good condition to the front and rear yards. Recommendation: Nil $ 0.00 Page 6 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. b) 3.3.0 Trees / Shrubs It was observed that there were small areas of gardens to this property. There was a small garden area to the rear yard with small shrubs and a number of trees in good condition. The garden running along the front boundary with small shrubs was also in good order. Recommendation: Trim back existing small trees & remove creepers from picket fence areas. $1,000.00 BUILDING EXTERNAL No. 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.1 a) 3.3.2 a) b) c) d) 3.3.3 531469465 Checked Description Cladding Roof Service Pipes Flue Trims Windows No. 3.3.7 3.3.8 3.3.9 3.3.10 3.3.11 Checked Description Doors Painting Blinds Pergola Deck: Verandah Cladding Brickwork It was observed that the property was a mixture of painted & rendered brickwork all that appeared to be in good condition. Recommendation: Nil Roof Slate roofing Nil Recommendation: Nil Corrugated iron roofing The externally roofing material to the entire building was corrugated iron. This roofing to this area was also visually inspected from ground level and it appeared that the roofing material did appear to be in good condition. Recommendation: Nil Guttering The existing gutters were visually inspected from ground level & appeared to be in poor condition, rusted, out of level & were not operating as required. Recommendation: Replace all gutters (approx. 84lin.M) with new colorbond gutters (profiles to match existing), as per the DHS Part 2 Reference Specification Edition 11 (Part 15 Roofing). Downpipes The existing downpipes were inspected from ground level & appeared to be in good condition & were operating as required. Recommendation: Replace all downpipes (x6No.) with new colorbond down pipes (size to match existing), connect & seal to the storm water line, as per the DHS Part 2 Reference Specification Edition 11 (Part 15 Roofing). Service Pipes It was observed the existing service pipes were in good condition & operating as required Recommendation: Nil Page 7 of 34 $ 0.00 $ 0.00 $ 0.00 $5,450.00 $1,950.00 $0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.3.4 3.3.5 a) b) c) d) 3.3.6 3.3.7 a) b) c) d) 531469465 Rooming House Property Assessment Report Flue All flues to this property were visually inspected from ground level & were observed to be in good condition. Recommendation: Nil Trims Fascia The general condition of the existing timber fascia were in good condition. Recommendation: Nil Bargeboards Nil Recommendation: Nil Eaves It was observed that the timber eaves were in good condition Recommendation: Nil Weatherboards Nil Recommendation: Nil $0.00 $0.00 $0.00 $0.00 $0.00 Windows It was observed that all windows were timber double hung. The enclosed light court was metal framed painted. Recommendation: Adjust & ease all windows, including the servicing of the existing operating system & hardware, to ensure proper & easy operation. (All) Repair flaking paint & 3no small rotted sill sections. Doors Front Door The existing front door was observed to be in good condition. Recommendation: Nil Rear Door The rear exit door was observed to be in good condition. Recommendation: Nil Security Doors It was observed that there was a security door to the front entry in good condition. There were no security screen doors on the laundry or light court exit door. Recommendation: Supply and install new security screen doors to light court & laundry. Flyscreen Doors Nil Recommendation: Nil Page 8 of 34 $2,050.00 $ 480.00 $ 0.00 $ 0.00 $ 930.00 $ 0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.3.8 3.3.9 3.3.10 3.3.11 531469465 Rooming House Property Assessment Report Painting It was observed that the finish to the external brickwork to the entire building was rendered & painted. It appeared to be in reasonable good condition with very little damage. The painting was worn, weathered, faded, deteriorated & repainting is required. Recommendation: Prepare & make good all defective surfaces. Remove all redundant fixture, fitting, nails, cleats etc. Clean & prepare all surfaces prior to commencement of painting. (Paint must not be applied until all surfaces are sanded to a smooth finish & all defects repaired). Preparation work must be inspected by the superintendent's representative prior to commencing any painting works. Repaint all previously painted or renewed external surfaces to the house and to the wing fences as per the DHS Part 2 Reference Specification Edition 11 (Part 23 Painting) $ 12,500.00 Blinds It was observed that there were no external blinds to this dwelling. Recommendation: Nil $ 0.00 Pergola Nil Recommendation: Nil. $ 0.00 Deck: Verandah There is a timber verandah with timber decking to the front façade of this property. It was observed that the timber decking to this area was weathered & deteriorated (especially to the exposed end). The hand rail to this area is 1000mm high, with a timber handrail & cast iron balustrade. Replacement of the timber decking to this area would be required. Recommendation: Replace the entire timber deck verandah to the front of this property. Page 9 of 34 $ 2,700.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. 3.4.0 BUILDING INTERNAL No. 3.4.1 3.4.2 3.4.3 3.4.4 3.4.5 3.4.1 a) b) c) d) e) f) 531469465 Checked Description Linings Finishes Doors Trims Windows No. 3.4.6 3.4.7 3.4.8 3.4.9 Checked Description Glazing Stairs Skylight Fittings Linings Floor – Carpet It was observed that there were carpet floor coverings to all bedsitters 1 – 18, and to the communal areas in this property: Stairs, store room, & the hallways. The carpet to all of these areas was old, in poor condition, worn, dirty & marked. Recommendation: Remove the existing floor covering & supply and install new polypropylene carpet & underlay (approx. 690sq.M.) to the following areas using the nominated supplier to bedsitter rooms 1-18 / store room / stairs / all hallway areas as per the DHS Part 2 Reference Specification Edition 11 (Part 22 Carpet). (Carpet is not a supplied item). Floor – Vinyl It was observed that there were vinyl floor coverings to the communal laundry area and the ground floor hallways. / main bathroom / air lock / toilet 1 / toilet 2 / laundry. The vinyl floor coverings to the ground floor halway areas were observed to be in good condition, however the common laundry is required to be replaced. Recommendation: Supply and Install new vinyl floor coverings (approx. 15.0sq.M), to the laundry as per the DHS Part 2 Reference Specification Edition 11 (Part 21 Resilient Materials) Floor – Tiled It was observed that there are ceramic tiled floors to the bedsitter to 5. All of the floor tiles to this bathroom appeared to be in good condition. Recommendation: Nil Walls – Solid Plaster & Plasterboard It was observed that the walls are solid brick throughout. There appeared to be some minor cracks to the internal solid plaster of various sections of the dwelling. These are of a minor nature and will be covered in the painting preparation works. Recommendation: Nil Walls - Tiled It was observed that there were ceramic tiles to the walls & splashbacks to the following areas throughout the property: Common laundry / Bedsitters 1-18 bathrooms & kitchenettes. Bedsitter areas with ceramic tiles appeared to be in reasonable condition, with repairs required to the common laundry. Recommendation: Replace wall tiling to the laundry. (Appx. 5.0m2.) Ceiling – Plasterboard It was observed that the plasterboard ceiling linings throughout the entire house were in good condition. Recommendation: Nil Page 10 of 34 $20,700.00 $2,250.00 $ 0.00 $ 0.00 $ 850.00 $0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.4.2 a) 3.4.3 3.4.4 3.4.5 a) b) 3.4.6 531469465 Rooming House Property Assessment Report Finishes Painting It was observed that the existing internal painting throughout the entire house was in poor condition, old, tired, dirty, & peeling to several areas. Recommendation: Remove all redundant fixture, fitting, nails, cleats etc. Re-fix all loose door stops, architraves, & skirtings. Clean & prepare all surfaces prior to commencement of painting. (Paint must not be applied until all surfaces are sanded to a smooth finish & all defects repaired). Preparation work must be inspected by the superintendent's representative prior to commencing any painting works. Repaint all previously painted or renewed internal surfaces. Previously stained surfaces may be re-strained if in good condition as per the DHS Part 2 Reference Specification Edition 11 (Part 23 Painting) Doors It was observed that the existing internal doors were in good condition but several were difficult to operate as they were getting stuck & several had loose hardware. The door to the meals area was in poor condition & damaged. Recommendation: Adjust & ease all doors, including servicing of the existing door hardware, to ensure proper & easy operation (All) Trims It was observed that internal trims throughout the house were in good condition. Recommendation: Nil Windows Window Covers It was observed that there were Holland blinds to all habitable room windows all of which appeared to be in reasonable condition & in good working order. Recommendation: Nil Insect screens It was observed that the existing insect screens are in good condition. Recommendation: Supply & install new colour coated flyscreens to bedroom 7 / bedroom 12 / bedroom 18 / (approx. x3No.) as per the DHS Part 2 Reference Specification Edition 11 (Part 17 Windows & Glazing) Glazing It was observed that there was no damaged or broken window glazing throughout the property Recommendation: Nil Page 11 of 34 $23,400.00 $ 440.00 $0.00 $ 0.00 $330.00 $0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.4.7 3.4.8 3.4.9 531469465 Rooming House Property Assessment Report Stairs It was observed that there is a 2no. common stairways to the property. The stair is of timber construction with a timber handrail & balustrade. There is carpet to the treads & risers with tread grips to each of the treads. The stairway, handrail, & balustrade is all in good condition. The current configuration of the stair treads are 240mm wide with the risers being 180mm. The handrail heights vary between 850mm to 760mm (top of the handrail). The configuration of the stairs handrail does not meet the current building requirements for stairs, handrails, & balustrades. Recommendation: There are two possible options for these stairs: a) Lodge an application ($90.00) to the building appeals board for them to make a judgment on keeping the current configuration for the stairs or whether they will require replacement to meet the current building regulations. b) Replace the existing handrails to meet the current building regulations Option a) is the recommend option as no major works are being carried out to the building or the existing stairs in the building. Due to this the stair could remain in their current configuration. $ 90.00 Skylight Nil Recommendation: Nil $0.00 Fittings It was observed that all fittings to this dwelling were in good condition. Recommendation: Nil $0.00 Page 12 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. 3.5.0 FIXTURES & FITTINGS No. 3.5.1 3.5.2 3.5.3 3.5.4 3.5.5 3.5.1 a) b) c) d) e) f) g) 3.5.2 531469465 Checked Description Kitchen Bathroom Toilet Laundry Lounge No. 3.5.6 3.5.7 3.5.8 3.5.9 3.5.10 Checked Description Bedrooms Passage Dining Kitchenette Entry Kitchen Cupboards It was observed that there is a laminate kitchen to all 18no. Bedsitters. All kitchens were in various conditions ranging from very poor to good. Kitchens on a as required bases shall be repaired or replaced as required. Recommendation: Repair, adjust & make good to joinery doors and drawers throughout & to bedsitters 4 & 6 replace benchtops. Silicone It was observed that there was a tiled splash back to the entire length of the kitchenettes benchtops that was in reasonable condition. The silicone sealing to the junction of the splashback & laminated benchtop is deteriorated & missing. Recommendation: Remove all silicone to all junctions to the kitchen at benchtops and splash back return joints. Re-silicone joints to match existing colour. O/H Cupboards It was observed that the existing kitchenettes had overhead cupboards without doors. Recommendation: Nil Shelving It was observed that the melamine shelving to the under bench cupboards and overheads are in good condition. Recommendation: Nil Sink It was observed that the there is currently a stainless steel single bowl sink with side drainer to the kitchenettes. All appeared to be in good condition. Recommendation: Nil Rangehood It was observed that there are re-circulatinig wall mounted rangehoods over electric freestanding up right stoves. These r/hoods are in reasonable condition with no scope to vent them externally. Recommendation: Nil Stove It was observed that each kitchenette has an electric freestanding up right stove. All appeared to be in reasonable order. Recommendation: Nil Bathrooms All 18no. bedsitters had an ensuite which comprised of a wall hung basin, toilet suite, shower and shaving cabinet. Minor repairs & replacements required to various fixtures and fittings. Recommendation: Bedsit 4 replace ‘O’ ring, Bedsit 9 replace shower curtain, Bedsit 6 replace basin, Bedsit 17 replace waste to basin, Bedsit 16 replace shower curtain & rose. Page 13 of 34 $2,650.00 $650.00 $0.00 $0.00 $ 0.00 $ 0.00 $0.00 $940.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 3.5.3 3.5.4 a) b) c) 3.5.5 3.5.6 a) b) 3.5.7 3.5.8 3.5.9 a) 531469465 Rooming House Property Assessment Report Toilet Each of the 18no. bedsitters had a toilet suite in their private ensuites which were generally in good order. Recommendation: Nil Laundry It was observed that the laundry consisted of a laminated joinery unit and benchtop together with an inset trough and 2no. washing machines. The appliances were in good condition & operating as required. Minor repairs were required to the wall tiling. Recommendation: Supply & installation of x1No. row of ceramic wall tiles adjacent to the coin dispeser. Taps It was observed that the taps & outlets to the laundry trough & washing machine were in poor condition, & replacement was required. Recommendation: Nil Poison Cabinet It was observed that the laundry currently does not have a poison cabinet. Recommendation: Supply & install a new child-proof poison cabinet to the laundry as per the DHS Part 2 Reference Specification Edition 11 (Part 13 Joinery). Lounge Nil Recommendation: Nil $ 0.00 $ 0.00 $ 0.00 $ 385.00 $0.00 Bedrooms Bedsitters It was observed that there were x18No. bedsitters. Generally, most of the bed sitter were of reasonable sizes & were adequate for the residence needs. Recommendation: Nil Robes It was observed that each of the bedsitters 1 – 18 had various sized free standing robes in these rooms, all of which were observed to be in varying condition. Generally, all of the bedrooms & the bed sitter were adequate for the residence needs. Recommendation: Supply & install new built in laminated joinery robes (2000mm high X 900mm wide with hanging rod & shelves) to each bedsitter. $0.00 $ 18,000.00 Passage It was observed that there were several areas of passage ways providing access to each of the rooms. All passageways were reasonable sizes & adequate for the residence needs. Recommendation: Nil $0.00 Dining Nil Recommendation: Nil $0.00 Kitchenette Nil to common areas. Recommendation: Nil $ 0.00 Page 14 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. 3.5.10 3.6.0 Entry It was observed that the entry area was a reasonable size & adequate for the residence needs Recommendation: Nil $0.00 BUILDING & SITE SERVICES No. 3.6.1 3.6.2 3.6.1 a) b) c) d) 3.6.2 a) b) c) d) e) 531469465 Checked Description Hydraulic Electrical No. 3.6.3 3.6.4 Checked Description Mechanical Fire Services Hydraulic Supply It was observed that the existing water & gas supplies were operating as required Recommendation: Nil Meter It was observed that the existing water meter & gas meter both appeared to be in good condition. Recommendation: Nil Hot Water Unit It was observed that the existing free standing gas external hot water unit was in good operating order & operating as required Recommendation: Nil Garden Taps It was observed that the existing rear garden tap was operating as required. Recommendation: Nil Electrical Meter It was observed that the existing electrical meter was in good condition. Recommendation: Nil Switchboard It was observed that the existing electrical switchboards were in good condition with the requirement for RCD’s to be installed on light & power circuits. Recommendation: Supply and install new RCD’s to existing switchboards & label circuits. Wiring No electrical wiring was observed. Recommendation: Nil Smoke Detector It was observed that there were multi detectors, smoke detectors, & thermal detectors to each area in this property. Recommendation: Nil Light Fittings It was observed that that all of the light fittings were in good condition & operating as required. There was 3no. cracked oyster light fittings encountered to be replaced. Recommendation: Replace 3no. oyster light fittings. Page 15 of 34 $0.00 $0.00 $0.00 $0.00 $0.00 $1,600.00 $0.00 $0.00 $330.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. f) g) 3.6.3 a) b) c) d) 3.6.4 a) 531469465 Rooming House Property Assessment Report Light Switches It was observed that that all of the light switches were in good condition & operating as required. Recommendation: Nil Power Outlets It was observed that that all of the power outlets were in good condition & operating as required. All bedsitters had multi powerpacks installed. Recommendation: Supply and install thermally protected GPO’s to all bedsitters. Mechanical Air-Conditioner There was no air conditioner to this dwelling. Recommendation: Nil Heater It was observed that there was hydronic heating to this property. The heater unit (Brivis) was located under the boiler room. This heating system was operating as required. Recommendation: Nil Exhaust Fan It was observed that the existing ceiling exhaust fans to the bathrooms were operating as required. Recommendation: Clean all existing exhaust fans Rangehood It was observed that the existing rangehood to the kitchenettes were operating as required. Recommendation: Nil Fire Services Fire Services It was observed that Fire Services including fire alarms, sprinklers systems, detection systems, emergency lighting, & fire fighting devices were provided & maintained to this property. Recommendation: Nil Page 16 of 34 $0.00 $1,800.00 $0.00 $0.00 $300.00 $0.00 $0.00 41-43 Jackson Street, St. Kilda. Vic. 3182. Rooming House Property Assessment Report Dan Lucin Building Designers P/L. 4.0 INDICATIVE COSTING SUMMARY: General Maintenance Costs associated to the works referenced are indicative only, with the intention of providing an approximate value for the purpose of budget preparation. Some items require further detailed documentation to provide an accurate quotation base. AREA ITEM CHECKLIST ITEM COST 3.2.0 Site Elements 3.2.3 (b) 3.2.3 (d) 3.2.7 3.2.12 Fencing: Front Fence Fencing: Rear Fence Garden Shed Landscaping: Trees/Shrubs Sub-Total $ 1,850.00 $ 2,450.00 $ 1,600.00 $ 1,000.00 $6,900.00 3.3.0 Building External 3.3.2 (c) 3.3.2 (d) 3.3.6 Roof: Guttering Roof: Downpipes Windows 3.3.7 (c) 3.3.8 3.3.11 Door: Security Doors Painting Deck: Verandah Sub-Total $ 5,450.00 $ 1,950.00 $ 2,050.00 $ 480.00 $ 930.00 $ 12,500.00 $ 2,700.00 $26,060.00 Sub-Total $ 20,700.00 $ 2,250.00 $ 850.00 $ 23,400.00 $ 440.00 $ 330.00 $ 90.00 $48,060.00 Sub-Total $ 2,650.00 $ 650.00 $ 940.00 $ 385.00 $ 18,000.00 $ 4,030.00 $26,655.00 3.4.0 3.5.0 ITEM 3.2.0 3.3.0 3.4.0 3.5.0 531469465 Building Internal Fixtures & Fittings 3.4.1 (a) 3.4.1 (b) 3.4.1 (e) 3.4.2 (a) 3.4.3 3.4.5 (b) 3.4.7 3.5.1 (a) 3.5.1 (b) 3.5.2 3.5.4 (a) 3.5.6 (c) 3.6.2 (e) Linings: Carpet Linings: Vinyl Linings: Walls: Tiled Finishes: Painting Doors Insect Screens Stairs Kitchen: Cupboards Kitchen: Silicone Bathroom: Fixtures Laundry: Poison Cabinet Bedrooms: Robes Electrical: Light fittings AREA Site Elements Building External Building Internal Fixtures & Fittings COST $ 6,900.00 $ 26,060.00 $ 48,060.00 $ 26,655.00 Sub-Total Contingency (10.0%) TOTAL $107,675.00 $ 10,767.50 $118,442.50 Page 17 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 5.0 Rooming House Property Assessment Report ROOMING HOUSE STANDARDS: 5.1 ROOMING HOUSE STANDARD EXTRACT The following standards are applicable to all rooming houses in this program and are extracted from the Community Housing Standards Section 6.7. The consultant will be required to confirm any inconsistencies from standards 6.7. 6.1 Communal Kitchens Where a commercial kitchen or individual facilities (kitchenettes) are not provided to all room, a communal kitchen shall be provided and located on the ground floor. Provide either one 4 burner cook-top to every five residents together with a griller and oven to every ten residents (or part thereof) or at least one upright 4-burner stove complete with a griller and oven to every five residents (or part thereof) without individual kitchenette facilities. Kitchen cupboards adequate for the number of tenants shall be provided for communal use together with work benches. One 1&half or 1& three quarter centre bowl stainless steel with sink with double drainer shall be provided to every ten residents (or part thereof) in each communal kitchen. 6.2 Communal Bathrooms Provide at least one bathroom to every six residents (or part thereof) without en-suite facilities with a minimum of one bathroom to each floor of a rooming house containing bedrooms. Bathrooms shall not open directly onto living area. In bathrooms located above ground floor, provide a floor waste with a floor grade 1:100 towards the waste. A privacy latch with occupancy indicator shall be installed to each communal bathroom door. Each bathroom shall contain the following: A walk in shower recess with shower base shower screen with hinged door A separate bath Hand basin with impervious splash back Mirror located above hand basin 6.3 Communal Laundry Provide a communal laundry located on the ground floor with at least one washing and one clothes dryer to every twelve residents (or part thereof) Provide a stainless laundry trough with hot and cold water taps at a ration of one per washing machine 6.4 Communal Toilets Provide at least one toilet to every six residents (or part thereof) without en-suite facilities with a minimum of one toilet to each floor of the rooming house. Toilet s shall be located separately to the bathroom. Toilets shall not open directly onto living areas. 531469465 Page 18 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report 5.2 COMPLIANCE TO THE ROOMING HOUSE STANDARD All relevant areas in this property were assessed against the rooming house standards & the following observations were made: 5.2.1 Communal kitchens The communal kitchen located on the ground floor of the property was found to meet the requirement of the rooming house standards except for the non-conforming sink. Please refer to item 3.5.1 (e) Kitchen: Sink [page 13]. 5.2.2 Communal bathrooms The communal bathroom to this property was located on the first floor level & consisted of a shower enclosure, & vanity unit. This bathroom did not meet the rooming house standards as it does not have a separate bath & as a minimum a bathroom is required to each floor level (bedsitters are located on both ground floor & first floor level). 5.2.3 Communal Laundry The communal laundry was located on the ground floor and provided the required facilities listed in the rooming house standards. 5.2.4 Communal toilet The communal toilets at this property were located on ground level & first floor level & provided the facilities as listed in the rooming house standards. 5.2.5 Existing Bedroom / Bedsitter sizes This property consisted of 7 rooms (6 bedrooms & 1 bedsitters room). The bedsitter room with en-suite & require facilities did meet the require room size requirements. 5 of the 6 bedrooms at this property also met the requirements of the rooming house standards for bedrooms with one bedroom being under the room size requirements (Bedroom 5). 5.3 COMPLIANCE TO THE BUILDING CODE OF AUSTRALIA (BCA) All areas in this property were assessed against the current requirements of the Building Code of Australia & the following non-compliant items were found: 5.3.1 Staircase The internal staircase was found to not comply with the current requirements of the BCA. (Please refer to item 3.4.7 Stairs) due to the handrail not meeting the required height (min 1,000mm). 5.4 PLANNING CONTROLS, HERITAGE OVERLAYS & HERITAGE VICTORIA. Heritage Victoria ia an organization that identifies & protects Victoria’s most significant cultural heritage resources. It maintains the Heritage Victoria Register & database that contains information about Victorian Heritage places and Precincts. This property was not found to be on the Heritage Victoria Register & Database. This property was however impacted by the following Planning Zones & Overlays: Planning Zone Residential 1 Zone (R1Z) Schedule to the Residential 1 Zone Heritage Overlay (HO) Heritage Overlay Schedule (HO5) Planning Overlays 531469465 Page 19 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 6.0 Rooming House Property Assessment Report CONCLUSION: This site is in overall reasonable condition with several areas require maintenance & minor repairs to rectify. The items indicated are important in providing & improving the health, safety, & comfort of the property for the current residents. The items in this report have been addressed with consideration given to the Asset Development & Innovation (ADI) checklist, the Community Housing Standards, the Department of Human Services business rules & to the social environment & client group. Several of the items highlighted are maintenance issues that have been neglected & now require replacement or repairs. The main areas that require attention are: 1. The existing timber floors to the original two storey building are bouncy & squeaky & require repairs, re-packing & making good; 2. The existing gutters & downpipes are weathered, in poor condition & require replacement; 3. All internal & external surfaces was tired, worn, deteriorated and require repainting; 4. The existing first floor verandah timber decking is in poor condition, weathered & deteriorated & requires replacement with a new timber decking. Replacement of the existing handrail will also be required to this area as it does not comply with the current building regulations; 5. The existing carpet floor covering throughout the entire property are in poor condition & require replacement; 6. The communal kitchen has limited shelving & the installation of further overhead cupboards would provide the tenants with more storage to the kitchen; 7. The existing bedrooms & bed sitter currently do not have built in robes & new built in robes are required as per the community housing standards. 8. The existing staircase configuration does not meet the current Building Code of Australia requirements. By repairing or replacing all of the indicated internal and external items will ensure the property provides a safe health & comfortable dwelling for the current residents. It will also improve the dwelling appearance and ensures that very little maintenance is required in the near future. 531469465 Page 20 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.0 Rooming House Property Assessment Report APPENDICES: 7.1.0 PHOTOGRAPHS 7.2.0 EXISTING CONDITION DRAWINGS: 7.3.0 PROPERTY COST ASSESSMENT (PCA) FORM 7.4.0 ROOMING HOUSE COSTING SPREADSHEET 7.5.0 ROOMING HOUSE COMPLIANCE SPREADSHEET 7.6.0 ROOM HOUSE – Planning Controls 7.7.0 ROOM HOUSE – Heritage Overlay 7.8.0 ROOM HOUSE – Historic Building Register 531469465 Page 21 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.1.0 Rooming House Property Assessment Report PHOTOGRAPHS Figure 7.1.1: Existing front facade Figure 7.1.4: Existing rear yard Figure 7.1.2: Existing bin enclosure & front fence Figure 7.1.5: Rear carpark area Figure 7.1.3: Existing rear facade Figure 7.1.6: Existing R.O.W. 531469465 Page 22 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report Figure 7.1.7 Existing side yard Figure 7.1.10 Existing light court stair Figure 7.1.8 Laundry Figure 7.1.11 Existing entry stair Figure 7.1.9 Front balcony 531469465 Page 23 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report Figure 7.1.12 Existing heating unit (under stairs) Figure 7.1.15 Existing entrance hall Figure 7.1.13 Existing Lightcourt Figure 7.1.16 Existing bedsitter 1 Kitchen Figure 7.1.14 Existing lightcourt Figure 7.1.17 Existing bedsitter 1 Ensuite 531469465 Page 24 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report Figure 7.1.18 Existing bedsitter 1 Figure 7.1.21 Existing bedsitter 2 Figure 7.1.19 Existing bedsitter 2 Kitchen Figure 7.1.22 Existing bedsitter 3 Ensuite Figure 7.1.20 Existing bedsitter 2 Ensuite Figure 7.1.23 Existing bedsitter 3 Kitchen 531469465 Page 25 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report Figure 7.1.24 Existing bedsitter 3 Figure 7.1.27 Existing bedsitter 6 kitchen Figure 7.1.25 Existing bedsitter 6 ensuite Figure 7.1.28 Existing rear light court Figure 7.1.29 Existing first floor hallways Figure 7.1.26 Existing bedsitter 6 531469465 Page 26 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. Rooming House Property Assessment Report Figure 7.1.30 Existing ground floor entry Figure 7.1.32 Existing hydronic heating Figure 7.1.31 Existing stair landing 531469465 Page 27 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.2.0 Rooming House Property Assessment Report EXISTING CONDITION DRAWINGS: Please find attached the following drawings detailing the layout of the residence: Drawing No: 29020 41JAC 01/03 Existing Conditions Site Plan Drawing No: 29020 41JAC 02/03 Existing Conditions Ground Floor Plan Drawing No: 29020 41JAC 03/03 Existing Conditions First Floor Plan 531469465 Page 28 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.3.0 Rooming House Property Assessment Report PROPERTY COST ASSESSMENT (PCA) FORM 531469465 Page 29 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.4.0 Rooming House Property Assessment Report ROOM HOUSE – COSTING SPREADSHEET 531469465 Page 30 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.5.0 Rooming House Property Assessment Report ROOM HOUSE – COMPLIANCE SPREADSHEET 531469465 Page 31 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.6.0 Rooming House Property Assessment Report ROOM HOUSE – PLANNING CONTROLS – (There are no site specific planning controls.) 531469465 Page 32 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.7.0 Rooming House Property Assessment Report ROOM HOUSE – HERITAGE OVERLAY – (The site is governed by H.05.) 531469465 Page 33 of 34 41-43 Jackson Street, St. Kilda. Vic. 3182. Dan Lucin Building Designers P/L. 7.8.0 Rooming House Property Assessment Report ROOM HOUSE – HISTORIC BUILDING REGISTER – (This property is not on the historic building register .) 531469465 Page 34 of 34