T: 01246 455565 F: 01246 455244 W: www.reconelectrical.co.uk E: sales@reconelectrical.co.uk Recommended Lux Levels The following guidance tables provide recommended lux levels for specific working areas within commercial, industrial and public sector buildings. These figures are based on the recommended lux levels by CIBSE (Chartered Institute of Building Services Engineers) and the code for interior lighting. Tables are for guidance only. Suggested Lux Level 120 250 120 500 250 500 Domestic General lighting Kitchen Bedrooms Sewing room Bathroom Dining room Education Classroom, tutorial rooms Lecture hall Technical drawing rooms Practical rooms & laboratories Computer practice rooms Entrance halls Circulation areas & corridors Stairs Sports halls, gymnasiums & pools School canteens Suggested Lux Level 300 500 750 500 300 200 100 150 400 300 Retail Sales area Till area Wrapper table Dressing rooms Shop window (crowded street) Shop window (commercial) Car Parks Parking bays (multi storey / underground) Access lanes (M-S/UG) Ramps (M-S/UG) Corners (M-S/UG) Intersections (M-S/UG) Multi storey roof level Entrance / exit zones (M-S/UG) day time Entrance / exit zones (M-S/UG) night time Pedestrian areas (M-S/UG) Stairs & lifts (M-S/UG) Units 1-6 Ambrose Buildings, Broombank Road, Chesterfield, Derbyshire, S41 9QJ VAT Reg: 598 6371 75 Company Reg: 3191383 Suggested Lux Level 300 500 500 300 1600 3000 Suggested Lux Level 75 75 150 150 150 30 300 75 100 100 Cashier desk, till Kitchen Suggested Lux Level 300 500 General lighting 250 Public Houses Hotels & Restaurants Reception & porters desk Kitchen Self-service restaurant Buffet Conference rooms Corridors Bathroom (hotel suite) Toilets (hotel suite) Foyers Dining room Halls Bathrooms (general) Nursing Homes Entrance lobbies Lounges (communal) Kitchens Bathrooms Toilets Corridors Staircases Quiet / rest rooms Dining rooms Stores Suggested Lux Level 300 500 300 300 500 100 150 100 200 250 120 Exhibitions & Libraries General lighting Very illuminated Offices Filing, copying etc… Writing, typing, reading, processing Technical drawing CAD workstations Conference & meeting rooms Reception area Archives Design office Toilets General lighting Precision assembly Suggested Lux Level 250 500 Suggested Lux Level 300 500 750 500 500 300 200 1,000 250 120 1500 250 Suggested Lux Level 200 300 300 150 100 100 100 100 200 Hospitals Waiting rooms corridors (during day) Corridors (during night) Day rooms Staff office Staff rooms Simple examination room Operating theatre Bathroom & toilets for outpatients Suggested Lux Level 200 200 50 200 400 300 300 1,000 200 100 Information provided by Kosnic Recon Electrical Ltd, Units 1-6 Ambrose Buildings, Broombank Road, Chesterfield, Derbyshire, S41 9QJ VAT Reg: 598 6371 75 Company Reg: 3191383