Opportunities & Alternatives “Effective Treatment.” MEKICS MV2000 SU:M Series MA-2014-4-001 Rev.1 A Leading Respiratory Care Company MEKICS has always emphasized research and development as its top corporate priority. The company approaches R&D through innovative, nimble and translational methodologies. This three-fold dynamic allows MEKICS to continue its over-arching commitment to enhancing quality of life. True to the company’s founding mission, MEKICS focuses its R&D efforts on developing the kinds of products people need most. By developing therapies for respiratory disorder, MEKICS has significantly advanced the science and understanding of these prevalent disease processes. This rich body of knowledge and wealth of experience positions MEKICS on the cutting edge for developing unique, innovative, finished products and to partnering successfully with other developers. Intensive Care Solution MV2000 Focus on MV2000 All in One Conventional to HFO. Neonate to Adult. Low Cost of Maintenance Optimal Care with multi function Intensive Care Solution MV2000 MEKICS’s Approach to Respiratory Care HFT500 NIV Ventilator Patient Monitor MP1300 MV2000 “MEKICS Solutions” Intensive Care Solution MV2000 Market Dynamics & Positioning MV2000 SU:M Series Price Humming v :Metran VN500 : Drager Stephenie, Sophie MEKICS Competitor Servo-I : Maquet V500 : Drager Avea : Carefusion G5 : Hamilton PB840, : Covidien SU:MNEO MEKICS SU:M3 MEKICS SU:M2 MEKICS Specification Intensive Care Solution MV2000 Market Competitors for SU:M Series MEK MV2000 Carefusion AVEA Intensive Care Solution MV2000 Marquet SERVO-I Drager Savina Covidien PB840 MV2000 SU:M Series Model Mode Optional Mode SU:M 1 PACV, PSIMV,VACV, VSIMV, Spont, Apnea Backup, O2Stream® SU:M 2 PACV, PSIMV,VACV, VSIMV, Spont, Apnea Backup, O2Stream® tBievel, PRVC, Auto Vent SU:M 3 SU:M NEO PACV, PSIMV,VACV, VSIMV, Spont, Apnea Backup, O2Stream® tBilevel, PRVC, Auto Vent, TCPL-AC, TCPL-SIMV, PV-Tool,AwPRV HFV (SHFV®DHFV®) PACV, PSIMV Spont, Apnea Backup, O2Stream® TCPL-AC, TCPL-SIMV, PV-Tool HFV (SHFV®DHFV®) TCPL-AC, TCPL-SIMV, PV-Tool, AwPRV Display 12.1” Touch Color LCD( Optional 17”) Patient Type Infant/ Pediatric/Adult(1Kg~150Kg) Volume 2ml~2,500ml Respiratory Rate 0~150bpm Optional EtCO2, SpO2, Nasal Cannula for O2Stream® Intensive Care Solution MV2000 MV2000 Feature + Benefits Why SU:M Series “High Performance with MEKICS unique technology.” Conventional to HFO only use one touch without circuit change. “Optimal Care in Respiratory with unique technology.” Intensive Care Solution MV2000 O2Stream® HFT application – Jet Flow, Humidity High Oxygen -Minimized Dead Space of upper airway -Support Acute to Weaning Patient Application -High Flow Therapy Oxygen Blender + Pressure Limitation -Nasal Continuous Oxygen Blended Flow Intensive Care Solution MV2000 Auto Vent Basic concept is MMV and PRVC(Minute Volume Ventilation) Automatically changed to ACV, SIMV and Spont+PS according to Patient’s condition. ACV SIMV Intensive Care Solution MV2000 Spont+PS HFV of SU:M3 SHFV and DHFV DHFV has intermediate exhaled time. Additional, it has CMV Rate and Ex_Time. Intensive Care Solution MV2000 HFV of SU:M3 Benefit of DHFV(HFV+IMV) - Available Measuring EtCO2 in Ex_Time. - Intermediately CMV Breathing Increasing CO2 exhalation at insufficient ventilation of SHFV - Low Maintenance Cost Intensive Care Solution MV2000 2015 New Software Version 2.50 1) AwPRV Mode : AwPRV mode added. – Optional function. 2) Circuit Check : Breathing Circuit Check added in the turn on process of the system Note : The ‘Circuit Check’ should be done for Pneumatic Soft Ware Version 2.50 ‘Circuit Volume Compensation’ before use for safety using the system. Intensive Care Solution MV2000 3) Leak Compensation ‘Tube compliance volume compensation function’ is added in Volume support mode ; (VACV, VSIMV). 4) Expiration Pressure Sensor disconnected and Proximal Pressure sensor disconnected detection function added. Safety is improved at expiration pressure port and/or proximal pressure sensor disconnection. Pneumatic Soft Ware Version 2.50 Pneumatic Soft Ware Version 2.50 “Safety” Intensive Care Solution MV2000 Improved functions 1) Improved the Volume Support against patient self-breath. : the possibility of lung collapse improved in VACV, VSIMV mode. Note: New MV2000 volume support(VACV, VSIMV) is a very useful mode in patient who fail to Ventilator have acute lung injury. If set up correctly the patient, even with a partial respiratory drive, should incur minimal work in breathing.(Adequate Volume support). Care must be taken that the patient does not hyperventilate and develop significant respiratory Pneumatic Soft Ware Version 2.50 alkalosis. Intensive Care Solution MV2000 2. Improved functions 2) Improved P-V Tool : Bi-direction (Pressure and Volume Curve) measuring process. 3) Improved the leak compensation. Mask On: Leak flow Up to 20lpm, Mask Off: Up to 6lpm Intensive Care Solution MV2000 3. Caution 1) Relative leak compensation. When leak flow is displayed, need clarified ‘Real leak’ or’ Temporal leak’. (Patient’s breathing should be checked.) Specially, ‘Mask On’ function should be used in non-invasive ventilation. 2) After Expiration Flow Sensor cleaning or sterilization, The sensor should be dried well. If the system has a calibration with the sensor which is not cleaned or dried well, it would make an abnormal operation. Normally the system does not need the Inspiration-Expiration Calibration process when is not there any mechanical sensor changing, Especially the Expiration Flow Sensor. When the user executes an Inspiration-Expiration Calibration, should be checked a perfect condition of the Expiration Flow sensor. Flow Zeroing calibration does not need to do very often, because the system has a Flow Zeroing calibration automatically when the system has stopped and restart. When the system has an Inspiration-Expiration Calibration after Flow Zeroing is not a right process. Intensive Care Solution MV2000 MV2000 Composition Model Description MV2000 Main Unit Pneumatic System(Body) LCD Ass’y 12.1 Inch Touch Screen Mobile Cart 4 Wheel Mobile Cart Circuit Arm Circuit Arm Test Lung 2L Air, O2 Hose High Pressure Air, O2 Hose *Local sourcing. Item Description Patient Circuit Reusable/ Disposable Patient Circuit Humidifier Set Main body, Temp Sensor, Heater Wire Proximal Sensor Adult, Neonate Intensive Care Solution MV2000 Ventilator Operation Guidelines Content 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Components & How to connect with circuit Circuit Check Patient Type Mode Display Monitoring Graphics Tools Events Alarm Intensive Care Solution MV2000 1. Components & How to connect with circuit Exp. From Patient Insp. To Patient Intensive Care Solution MV2000 2. Circuit Check < “Circuit Check” > 1. Purpose : Leakage detection in Circuit & Ventilator 2. Order : Test Lung Open Calibration Click Closed Y-piece ( after 3 secs) “Circuit Check” Click ‘Ok’ button Standby Mode Intensive Care Solution MV2000 3. Patient Type < New Patient > 1. Select “New Patient” 2. Select Male/Female/Pediatric/Neo 3. Adjust Height ( automatically changing parameters) 4. Start Intensive Care Solution MV2000 < Last Patient > 1. Select “Last Patient” 2. Select “Start key” *Caution: if height is selected, screen is changed to New patient, again. 4. Modes 1. Select right upper “Modes” 2. Select “VENT MODE” 3. After choosing specific parameters, and adjusted by encoder 4. Select “Accept” Intensive Care Solution MV2000 5. Display Setting mode Alarm Message Displaying Parameters Patient, Time, Neb Modes Setting Parameters(Volume,RR,TINSP,PSUPP,PEEP,O2 ) AC,LOCK I:E RATIO PRESSURE Graph FLOW Graph VOLUME Graph Intensive Care Solution MV2000 6. Monitoring <Table1> 1. Display Various ventilator’s values monitoring 2. Display internal tube Resistance & Leakage 3. Etc.( Spontaneous breathing, lung compliance ) < Table2 > 1. Display Spo2 , Etco2 , HFV , WOB Intensive Care Solution MV2000 7. Graphics 터 치 1. 5 kinds of Layouts 2. Changeable ‘Waveform’, ‘Loop’, ‘Trend’ 3. Changeable “Trend Timing” Intensive Care Solution MV2000 8. Tools < Insp. Hold > 1. After 14 secs of inspiration hold time, , measuring compliance, resistance, time constant by adding 1 sec 2. Display ‘CL’ , ‘RA’ , ‘E’ , ‘Tc’ < Exp. Hold > 1. After 14 secs of expiration hold time, measuring AutoPEEP by adding 2 secs 2. Display ‘AutoPEEP’ Intensive Care Solution MV2000 9. Events < Events > 1. Setting : Parameter Setting Data 2. Alarm : Alarm Data 3. All : Setting + Alarm Data Intensive Care Solution MV2000 10. Alarms HIGH LIMIT Setting Parameter LOW LIMIT < Alarm > 1. 1Page : Basic Ventilator Alarm 2. 2Page : Spo2 & Etco2 Alarm 3. Alarm Auto ON/OFF Intensive Care Solution MV2000