Opportunities & Alternatives “Effective Treatment.”
MEKICS MV2000 SU:M Series
MA-2014-4-001 Rev.1
A Leading Respiratory Care Company
MEKICS has always emphasized research and development as its top corporate priority.
The company approaches R&D through innovative, nimble and translational methodologies.
This three-fold dynamic allows MEKICS to continue its over-arching commitment to
enhancing quality of life. True to the company’s founding mission, MEKICS focuses its R&D
efforts on developing the kinds of products people need most. By developing therapies for
respiratory disorder, MEKICS has significantly advanced the science and understanding of
these prevalent disease processes. This rich body of knowledge and wealth of experience
positions MEKICS on the cutting edge for developing unique, innovative, finished products
and to partnering successfully with other developers.
Intensive Care Solution MV2000
Focus on MV2000
All in One
Conventional to HFO.
Neonate to Adult.
Low Cost of Maintenance
Optimal Care with multi function
Intensive Care Solution MV2000
MEKICS’s Approach to Respiratory Care
HFT500
NIV
Ventilator
Patient
Monitor
MP1300
MV2000
“MEKICS Solutions”
Intensive Care Solution MV2000
Market Dynamics & Positioning
MV2000 SU:M Series
Price
Humming v :Metran
VN500 : Drager
Stephenie, Sophie
MEKICS
Competitor
Servo-I : Maquet
V500 : Drager
Avea : Carefusion
G5 : Hamilton
PB840, : Covidien
SU:MNEO
MEKICS
SU:M3
MEKICS
SU:M2
MEKICS
Specification
Intensive Care Solution MV2000
Market Competitors for SU:M Series
MEK
MV2000
Carefusion
AVEA
Intensive Care Solution MV2000
Marquet
SERVO-I
Drager
Savina
Covidien
PB840
MV2000 SU:M Series
Model
Mode
Optional Mode
SU:M 1
PACV,
PSIMV,VACV,
VSIMV, Spont,
Apnea Backup,
O2Stream®
SU:M 2
PACV,
PSIMV,VACV,
VSIMV, Spont,
Apnea Backup,
O2Stream®
tBievel, PRVC,
Auto Vent
SU:M 3
SU:M NEO
PACV,
PSIMV,VACV,
VSIMV, Spont,
Apnea Backup,
O2Stream®
tBilevel, PRVC,
Auto Vent,
TCPL-AC,
TCPL-SIMV,
PV-Tool,AwPRV
HFV
(SHFV®DHFV®)
PACV, PSIMV
Spont,
Apnea Backup,
O2Stream®
TCPL-AC,
TCPL-SIMV,
PV-Tool
HFV
(SHFV®DHFV®)
TCPL-AC,
TCPL-SIMV,
PV-Tool, AwPRV
Display
12.1” Touch Color LCD( Optional 17”)
Patient Type
Infant/ Pediatric/Adult(1Kg~150Kg)
Volume
2ml~2,500ml
Respiratory Rate
0~150bpm
Optional
EtCO2, SpO2, Nasal Cannula for O2Stream®
Intensive Care Solution MV2000
MV2000
Feature + Benefits
Why SU:M Series
“High Performance with MEKICS unique technology.”
Conventional to HFO only use one touch without circuit change.
“Optimal Care in Respiratory with unique technology.”
Intensive Care Solution MV2000
O2Stream®
HFT application – Jet Flow, Humidity High Oxygen
-Minimized Dead Space of upper airway
-Support Acute to Weaning Patient
Application
-High Flow Therapy Oxygen Blender + Pressure Limitation
-Nasal Continuous Oxygen Blended Flow
Intensive Care Solution MV2000
Auto Vent
Basic concept is MMV and PRVC(Minute Volume Ventilation)
Automatically changed to ACV, SIMV and Spont+PS according to Patient’s
condition.
ACV
SIMV
Intensive Care Solution MV2000
Spont+PS
HFV of SU:M3
SHFV and DHFV
DHFV has intermediate exhaled time.
Additional, it has CMV Rate and Ex_Time.
Intensive Care Solution MV2000
HFV of SU:M3
Benefit of DHFV(HFV+IMV)
- Available Measuring EtCO2 in Ex_Time.
- Intermediately CMV Breathing
Increasing CO2 exhalation at insufficient ventilation of SHFV
- Low Maintenance Cost
Intensive Care Solution MV2000
2015 New Software Version 2.50
1) AwPRV Mode : AwPRV mode added. – Optional function.
2) Circuit Check : Breathing Circuit Check added in the turn on process of the system
Note : The ‘Circuit Check’ should be done for
Pneumatic Soft Ware
Version
2.50
‘Circuit Volume Compensation’ before
use for safety using the system.
Intensive Care Solution MV2000
3) Leak Compensation
‘Tube compliance volume compensation function’ is added in Volume support mode ; (VACV, VSIMV).
4) Expiration Pressure Sensor disconnected and Proximal Pressure sensor disconnected detection
function added.
Safety is improved at expiration pressure port and/or proximal pressure sensor disconnection.
Pneumatic Soft Ware Version 2.50
Pneumatic Soft Ware Version 2.50
“Safety”
Intensive Care Solution MV2000
Improved functions
1) Improved the Volume Support against patient self-breath.
: the possibility of lung collapse improved in VACV, VSIMV mode.
Note: New MV2000 volume support(VACV, VSIMV) is a very useful mode in patient who fail to
Ventilator have acute lung injury. If set up correctly the patient, even with a partial respiratory
drive, should incur minimal work in breathing.(Adequate Volume support).
Care must be taken that the patient does not hyperventilate and develop significant respiratory
Pneumatic Soft Ware Version 2.50
alkalosis.
Intensive Care Solution MV2000
2. Improved functions
2) Improved P-V Tool : Bi-direction (Pressure and Volume Curve) measuring process.
3) Improved the leak compensation.
Mask On: Leak flow Up to 20lpm, Mask Off: Up to 6lpm
Intensive Care Solution MV2000
3. Caution
1) Relative leak compensation.
When leak flow is displayed, need clarified ‘Real leak’ or’ Temporal leak’.
(Patient’s breathing should be checked.)
Specially, ‘Mask On’ function should be used in non-invasive ventilation.
2) After Expiration Flow Sensor cleaning or sterilization, The sensor should be dried well.
If the system has a calibration with the sensor which is not cleaned or dried well, it would make an
abnormal operation. Normally the system does not need the Inspiration-Expiration Calibration process
when is not there any mechanical sensor changing, Especially the Expiration Flow Sensor. When the
user executes an Inspiration-Expiration Calibration, should be checked a perfect condition of
the Expiration Flow sensor. Flow Zeroing calibration does not need to do very often, because the
system has a Flow Zeroing calibration automatically when the system has stopped and restart.
When the system has an Inspiration-Expiration Calibration after Flow Zeroing is not a right process.
Intensive Care Solution MV2000
MV2000 Composition
Model
Description
MV2000 Main Unit
Pneumatic System(Body)
LCD Ass’y
12.1 Inch Touch Screen
Mobile Cart
4 Wheel Mobile Cart
Circuit Arm
Circuit Arm
Test Lung
2L
Air, O2 Hose
High Pressure Air, O2 Hose
*Local sourcing.
Item
Description
Patient Circuit
Reusable/ Disposable Patient Circuit
Humidifier Set
Main body, Temp Sensor, Heater Wire
Proximal Sensor
Adult, Neonate
Intensive Care Solution MV2000
Ventilator Operation Guidelines
Content
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Components & How to connect with circuit
Circuit Check
Patient Type
Mode
Display
Monitoring
Graphics
Tools
Events
Alarm
Intensive Care Solution MV2000
1. Components & How to connect with circuit
Exp.
From Patient
Insp.
To Patient
Intensive Care Solution MV2000
2. Circuit Check
< “Circuit Check” >
1. Purpose : Leakage detection in Circuit & Ventilator
2. Order : Test Lung Open  Calibration Click  Closed Y-piece ( after 3 secs)  “Circuit Check”
 Click ‘Ok’ button  Standby Mode
Intensive Care Solution MV2000
3. Patient Type
< New Patient >
1.
Select “New Patient”
2.
Select Male/Female/Pediatric/Neo
3.
Adjust Height ( automatically changing
parameters)
4.
Start
Intensive Care Solution MV2000
< Last Patient >
1.
Select “Last Patient”
2.
Select “Start key”
*Caution: if height is selected, screen is changed to New
patient, again.
4. Modes
1.
Select right upper “Modes”
2.
Select “VENT MODE”
3.
After choosing specific parameters, and adjusted by encoder
4.
Select “Accept”
Intensive Care Solution MV2000
5. Display
Setting mode
Alarm Message
Displaying Parameters
Patient, Time, Neb
Modes
Setting Parameters(Volume,RR,TINSP,PSUPP,PEEP,O2 )
AC,LOCK
I:E RATIO
PRESSURE
Graph
FLOW
Graph
VOLUME
Graph
Intensive Care Solution MV2000
6. Monitoring
<Table1>
1. Display Various ventilator’s values monitoring
2. Display internal tube Resistance & Leakage
3. Etc.( Spontaneous breathing, lung compliance )
< Table2 >
1. Display Spo2 , Etco2 , HFV , WOB
Intensive Care Solution MV2000
7. Graphics
터
치
1. 5 kinds of Layouts
2. Changeable ‘Waveform’, ‘Loop’, ‘Trend’
3. Changeable “Trend Timing”
Intensive Care Solution MV2000
8. Tools
< Insp. Hold >
1. After 14 secs of inspiration hold time, ,
measuring compliance, resistance, time
constant by adding 1 sec
2. Display ‘CL’ , ‘RA’ , ‘E’ , ‘Tc’
< Exp. Hold >
1. After 14 secs of expiration hold time,
measuring AutoPEEP by adding 2 secs
2. Display ‘AutoPEEP’
Intensive Care Solution MV2000
9. Events
< Events >
1. Setting : Parameter Setting Data
2. Alarm : Alarm Data
3. All : Setting + Alarm Data
Intensive Care Solution MV2000
10. Alarms
HIGH LIMIT
Setting Parameter
LOW LIMIT
< Alarm >
1.
1Page : Basic Ventilator Alarm
2.
2Page : Spo2 & Etco2 Alarm
3.
Alarm Auto ON/OFF
Intensive Care Solution MV2000
Download