MEDIUM VOLTAGE E Flexible LSZH Rubber Single Core MV Power 19/33kV 90°C EPR Typical Applications Construction Power Cable for Mining, Industrial and Power Utility. Conductor Fine wire plain or tinned annealed copper to IEC 60228 and AS/NZS 1125 Conductor Screen Semi-Conductive Cross Linked Rubber Insulation Ethylene Propylene Rubber (EPR) Insulation Screen Semi-Conductive Cross Linked Rubber Metallic Screen Plain annealed copper wire Separator Polypropylene tape Jacket Low-Friction LSFLEX® T-10 (HFS-110-TP) Flame Retardant, Cross Linked, Thermoset, Elastomeric, Low Smoke Zero Halogen. Splash resistant to oil, skydrol, petrol, acid and sea water. Resists ozone and UV. Excellent abrasion resistance. Anti-Termite/Rodent Jacket is Available. Standard Core Configuration 1C: 1 Operating Temp Standards -40°C to +90°C AS/NZS 1125 AS/NZS 1429.1 Voltage Rating AS/NZS 3808 19000/33000 Volts AS/NZS 1660.5.1 AS/NZS 1660.5.2 Jacket Colour To customers specification AS/NZS 1660.5.4 AS/NZS 1660.5.6 NUMBER OF CORES (c) X CROSS SECTION AREA (mm2) 1c 35 1c 50 1c 70 1c 95 1c 120 1c 150 1c 185 1c 240 1c 300 1c 400 1c 500 1c 630 MINIMUM BENDING RADIUS (mm) 203 212 229 241 246 258 270 285 299 323 343 367 NOMINAL CONDUCTOR DIAMETER (mm) 7.8 9.2 10.8 12.8 14.5 16.3 18.0 20.3 22.5 26.0 29.2 32.8 NOMINAL INSULATION THICKNESS (mm) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 NOMINAL INSULATION DIAMETER (mm) 24.6 26.0 27.6 29.6 31.3 33.1 34.8 37.1 39.3 42.8 46.0 49.6 NOMINAL OVERALL DIAMETER (mm) 33.8 35.4 38.1 40.2 41.0 43.0 45.0 47.5 49.8 53.8 57.2 61.1 APPROX WEIGHT (kg/km) 1312 1654 2094 2389 2643 3006 3369 3942 4589 5527 6581 7864 IEC 60228 IEC 60332-1 IEC 60332-3-22 IEC 60754-2 IEC 60502-2 IEC 61034-1&2 MAXIMUM PULLING TENSION (kN) 3.5 5.0 7.1 8.3 9.6 11.1 12.8 15.6 18.6 23.6 28.6 35.1 ** There is a +/-2% tolerance to the NOMINAL values due to manufacturing process variations. TriCab is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time. NUMBER OF CORES (c) X CROSS SECTION AREA (mm2) 1c 35 1c 50 1c 70 1c 95 1c 120 1c 150 1c 185 1c 240 1c 300 1c 400 1c 500 1c 630 TREFOIL IMPEDANCE R1 X1 90°C 50 Hz ohm/km 0.707 0.150 0.492 0.143 0.347 0.138 0.263 0.130 0.206 0.124 0.165 0.119 0.136 0.116 0.104 0.112 0.084 0.108 0.065 0.104 0.052 0.101 0.041 0.098 R0 X0 20°C ohm/km 1.108 0.094 0.772 0.087 0.544 0.081 0.479 0.075 0.434 0.069 0.402 0.065 0.379 0.062 0.354 0.058 0.338 0.055 0.324 0.051 0.315 0.048 0.306 0.045 CAPACITANCE CONDUCTOR TO SCREEN µF/km 0.153 0.169 0.186 0.207 0.225 0.244 0.262 0.285 0.308 0.344 0.377 0.414 CURRENT RATING (Amps) BURIED BURIED IN IN DIRECT CONDUIT FREE AIR 15°C 15°C 30°C 188 165 195 223 195 234 271 240 291 325 287 355 369 326 407 414 366 463 466 413 527 554 478 618 601 537 703 679 611 813 763 688 929 850 776 1057 FAULT CURRENT RATING BURIED BURIED IN IN DIRECT CONDUIT FREE AIR 25°C 25°C 40°C 175 154 176 207 183 211 253 224 263 303 268 320 343 304 367 385 342 417 434 386 475 516 446 557 559 501 634 633 570 732 710 642 837 791 724 952 ACTIVE EARTH 1 SECOND 1 SECOND kA kA 5.0 5.0 7.2 7.2 10.0 10.2 13.6 10.2 17.2 10.2 21.5 10.2 26.5 10.2 34.3 10.2 10.2 42.9 57.2 10.2 10.2 71.5 90.1 10.2 ** There is a +/-2% tolerance to the NOMINAL values due to manufacturing process variations. TriCab is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time. 52 Tr i C a b - the wo rld’s m ost flexible cab le m anufacturer - i s s u e 1 8 . 0 Po c k e t E d i t i o n