ABSTRACT INTRODUCTION PROCEDURES CALCULATIONS AND LAB REPORT R load Measured RMS voltage Vrms R=40 Ω V=39.43 v R=60 Ω V=39.53 v R=80 Ω V=39.52 v RL load L= 200 mH R=10 Ω V=102.42 v R=30 Ω V=102.74 v R=50 Ω V=102.54 v RC load C = 40x10^-6 F R=10 Ω V=60.057 v R=30 Ω V=59.557 v R=50 Ω V=59.75 v Measured RMS current Irms I=0.9 A I=0.6 A I=0.45 A Measured Average power P P=32.8 w P=22.9 w P=16.9 w Measure pf Calculated Pf P/VI Pf=1.0 pf=1.0 Pf=1.0 I=0.9 A P=90.9 w I=0.84 A Load RL load R=10 R=30 R=50 RC load R=10 R=30 R=50 % error Pf=0.92 Pf=0.97 Pf=0.95 Theoretical pf Pf = cos(theta) 1 1 1 Pf=0.23 Pf=0.99 0.9935 21.25% P=85.9 w pf=0.39 Pf=0.995 0.999 17.98% I=0.78 A P=78.6 w Pf=0.59 Pf=0.98 0.999 22.37% I=0.9 A P=51.4 w Pf=0.07 Pf=0.95 0.14 9.79% I=0.8 A P=46.6 w pf=0.36 Pf=0.98 0.412 4.82% I=0.68 A P=39.5 w Pf=0.55 Pf=0.97 0.602 0.26% Measured Papp Measured pf Measured angle Theoretical Reactive angle power Q Complex power S % error 92.178w 86.3 w 79.97 w Pf=0.23 pf=0.39 pf=0.59 76.70 67.04° 53.84° 82.4° 68.57° 55.48° 89.7 79.46 54.57° +j +j +j 1.34% 0.25% 0.11% 54.05 w 47.65 w 40.63 w Pf=0.07 Pf=0.36 Pf=0.55 85.99° 68.90° 56.63° -81.9° -65.77° -52.03° 53.92 44.46 33.93 -j -j -j 0% 0% 0.33% 21.25% 17.98% 22.37% C = 0 uF C = 5 uF C = 10 uF C = 15 uF C = 20 uF C = 25 uF C = 30 uF C = 35 uF C = 40 uF C minimum = 20 RSM voltage 116.03 117.21 116.45 116.75 116.82 116.55 116.85 116.99 116.95 RMS current 0.9 0.69 0.48 0.32 0.28 0.39 0.56 0.76 0.98 AVG power 102.9 79.4 55.3 36.9 32.3 45.0 66.0 87.9 113.3 Power 0.39factor 0.39 0.49 0.65 0.92 0.97 0.66 0.43 0.31 0.23 Calculated Error pf