WATERJET COMPARTMENT VOID WATERJET COMPARTMENT VOID PUMP COMPARTMENT PUMP COMPARTMENT GENERATOR COMPARTMENT GENERATOR COMPARTMENT VOID VOID VOID VOID VOID VOID VESSEL PARTICULARS . SMALL PASSENGER CATAMARAN VESSEL (T) LENGTH: 65FT BEAM: 22FT DISPLACEMENT: 45LT NOTES: 1. ALL MEASUREMENTS IN FEET & INCHES 2. FRAME SPACING IS 18 INCHES 3. KEEL COOLER INSETS INBOARD PASSENGERS: 150 CREW: 2 WATERJET COMPARTMENT VOID PUMP COMPARTMENT GENERATOR COMPARTMENT VOID VOID VOID SHORE POWER HOUSE LOAD PLUG SHORE POWER ESS CHARGER PLUG MAIN AC SWITCHBOARD PORT EDN CHARGERS M 3 F STBD HVPDU PORT AC PANEL M ESS GPM12 QSB6.7 ISG200 PORT HVPDU VFD MAPS F STBD AC PANEL M ESS PORT BEL INVERTERS 24 AC LOADS AC LOADS 1 M GPM12 STBD BEL INVERTERS 24 24 3 MPCS MPCS 1 STBD EDN CHARGERS 24 VFD MAPS QSB6.7 ISG200 kW TOTAL SUMMER LOADS EMERGENCY WINTER LOADS 29.14 PORT DISTRIBUTION PANEL POWER PER PHASE (kW) AC LOADS INSTALLED CIRCUIT NAME CKT# V PH kW A PF 2 BATTERY SYSTEM CHILLER #1 208 3 4.49 15.6 0.8 6 MAIN DECK RECEPTACLES / PILOT HOUSE RECEPTACLES 120 1 1.44 12.0 1 1 AHU #1 4 Ton 208 2 5.52 33.2 0.8 3 ER BATTERY CHARGER 120 1 2.9 24.2 1 4 PILOT HOUSE BATTERY CHARGER 120 1 0.8 6.7 1 5 LED TV'S 120 1 0.72 6.0 1 13 CONDENSATE PUMP 120 1 0.86 7.2 1 14 WATERJET COOLING PUMP 120 1 0.86 7.2 1 kW TOTAL CIRCUIT NAME WINTER LOADS kW LF kW LF kW INVERTERS AC PANELBOARD 1.50 1.50 1.50 1.00 4.49 1.00 4.49 1.00 4.49 0.50 2.25 INVERTERS TRANSFORMER 0.18 1.44 0.60 0.86 0.60 0.86 0.60 0.86 0.30 0.43 TRANSFORMER MAIN AC SWITCHBOARD 0.24 1.00 5.52 1.00 5.52 0.00 0.00 0.50 2.76 PORT / STBD SWITCHBOARD EMCB 0.13 0.00 0.00 0.00 0.00 0.00 0.00 1.00 2.90 MAIN AC SWITCHBOARD AC PANELBOARD 0.48 0.00 0.00 0.00 0.00 0.00 0.00 1.00 0.80 0.60 0.43 0.60 0.43 0.00 0.00 0.00 0.00 INVERTERS LOADS 1.00 0.86 1.00 0.86 1.00 0.86 1.00 0.86 INVERTERS 1.00 0.86 1.00 0.86 1.00 0.86 1.00 0.86 5.9 kW 49.34A 2.76 5.8 kW 48.67A 5.8 kW 48.64A STDB DISTRIBUTION PANEL POWER PER PHASE (kW) PF N 13 kW 36.18A 13 kW 36.18A 10.9 kW 30.16A WINTER LOADS SUMMER LOADS EMERGENCY SHORE POWER 7.1 kW 19.66A L1 L2 L3 LF kW LF kW LF kW LF kW 7 FIRE PUMP (5HP) 208 3 5.04 17.5 0.8 1.50 1.50 1.50 0.00 0.00 0.00 0.00 1.00 4.49 0.00 0.00 8 BATTERY SYSTEM CHILLER #2 208 3 4.49 15.6 0.8 1.50 1.50 1.50 1.00 4.49 1.00 4.49 0.60 2.69 0.50 2.25 9 AHU #3 DAIKIN 4 TON 208 2 4.58 27.5 0.8 2.29 2.29 1.00 4.58 1.00 4.58 0.00 0.00 0.50 2.29 10 AHU #2 4 Ton 208 2 5.52 33.2 0.8 2.76 1.00 5.52 1.00 5.52 0.00 0.00 0.50 2.76 11 CONDENSATE PUMP 120 1 0.86 7.2 1 1.00 0.80 1.00 0.80 1.00 0.80 1.00 0.80 12 WATERJET COOLING PUMP 120 1 0.86 7.2 1 1.00 0.72 1.00 0.72 1.00 0.72 1.00 0.72 2.76 0.80 0.72 SPARE kW TOTAL 21.4 kW Amps TOTAL V-DROP [%] LF 0.86 A FROM kW 0.86 kW SHORE POWER LF 0.72 PH EMERGENCY AC VOLTAGE DROP ANALYSIS TO L3 0.80 V SUMMER LOADS 19.68 L2 2.76 17.6 kW Amps TOTAL 15.79 L1 2.90 AC LOADS INSTALLED CKT# N 29.14 SHORE POWER 8 kW 67.03A 6.1 kW 50.69A 6.5 kW 53.94A 16.1 kW 44.72A 16.1 kW 44.72A 8.7 kW 24.16A 8.8 kW 24.47A TOTAL 1.01 AHU TOTAL 2.97 INVERTERS BATT CHILLER TOTAL 2.28 INVERTERS BATT CHARGER TOTAL 2.92 INVERTERS LED TV'S TOTAL 3.00 INVERTERS FIRE PUMP TOTAL 3.37 INVERTERS RECEPTACLES TOTAL 6.52 INVERTERS PILOT HOUSE BATT CHARGER TOTAL 5.24 INVERTERS PUMPS TOTAL 2.83 AC SHORE POWER CHARGER SHORE POWER CHARGER PLUG MAIN AC SWITCHBOARD 0.52 SHORE POWER CHARGER BREAKER ESS CHARGER PANELBOARD 0.64 ESS CHARGER PANELBOARD STBD CHARGER 0.31 CONDUCTOR SIZES AC-00 - 1 CIRCUIT WITH: (3) #12 AWG ϕ CU, UL 1309, 90°C, 10 FT (1) #12 AWG N CU, UL 1309, 90°C (1) #12 AWG GND CU, UL 1309, 90°C AC-01 - 1 CIRCUIT WITH: (3) #6 AWG ϕ CU, UL 1309, 90°C, 15 FT (1) #6 AWG N CU, UL 1309, 90°C (1) #8 AWG GND CU, UL 1309, 90°C AC-01.1 - 1 CIRCUIT WITH: (3) #6 AWG ϕ CU, UL 1309, 90°C, 30 FT (1) #6 AWG N CU, UL 1309, 90°C (1) #8 AWG GND CU, UL 1309, 90°C AC-02 - 1 CIRCUIT WITH: (3) #2 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #2 AWG N CU, UL 1309, 90°C (1) #6 AWG GND CU, UL 1309, 90°C AC-02.1 - 1 CIRCUIT WITH: (3) #8 AWG ϕ CU, UL 1309, 90°C, 5 FT (1) #8 AWG N CU, UL 1309, 90°C (1) #10 AWG GND CU, UL 1309, 90°C AC-03 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 60 FT (1) #10 AWG GND CU, UL 1309, 90°C AC-04 - 1 CIRCUIT WITH: (3) #12 AWG ϕ CU, UL 1309, 90°C, 60 FT (1) #12 AWG GND CU, UL 1309, 90°C AC-05 - 2 CIRCUITS EACH WITH: (1) #12 AWG ϕ CU, UL 1309, 90°C, 60 FT (1) #12 AWG N CU, UL 1309, 90°C (1) #12 AWG GND CU, UL 1309, 90°C AC-06 - 1 CIRCUIT WITH: (1) #12 AWG ϕ CU, UL 1309, 90°C, 75 FT (1) #12 AWG N CU, UL 1309, 90°C (1) #12 AWG GND CU, UL 1309, 90°C AC-07 - 1 CIRCUIT WITH: (3) #12 AWG ϕ CU, UL 1309, 90°C, 85 FT (1) #12 AWG GND CU, UL 1309, 90°C AC-08 - 1 CIRCUIT WITH: (1) #12 AWG ϕ CU, UL 1309, 90°C, 160 FT (1) #12 AWG N CU, UL 1309, 90°C (1) #12 AWG GND CU, UL 1309, 90°C AC-09 - 1 CIRCUIT WITH: (1) #12 AWG ϕ CU, UL 1309, 90°C, 160 FT (1) #12 AWG N CU, UL 1309, 90°C (1) #12 AWG GND CU, UL 1309, 90°C AC-10 - 1 CIRCUIT WITH: (3) #8 AWG ϕ CU, UL 1309, 90°C, 5 FT (1) #8 AWG N CU, UL 1309, 90°C AC-11 - 1 CIRCUIT WITH: (3) #2 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #2 AWG N CU, UL 1309, 90°C (1) #6 AWG GND CU, UL 1309, 90°C AC-11.1 - 1 CIRCUIT WITH: (3) #6 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #6 AWG N CU, UL 1309, 90°C (1) #8 AWG GND CU, UL 1309, 90°C AC-11.2 - 1 CIRCUIT WITH: (3) #10 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #10 AWG N CU, UL 1309, 90°C (1) #10 AWG GND CU, UL 1309, 90°C AC-11.3 - 1 CIRCUIT WITH: (3) #10 AWG ϕ CU, UL 1309, 90°C, 15 FT (1) #10 AWG N CU, UL 1309, 90°C (1) #10 AWG GND CU, UL 1309, 90°C TO HVPDU M 3 F M ESS GPM12 QSB6.7 ISG200 AC PANEL AC PANEL BATTERY CHARGER BATTERY CHARGER CHARGER DISCONNECT SWITCH LVPDU DISCONNECT SWITCH BATTERY SWITCH 24VDC HOUSE BATTERY LVPDU DISCONNECT SWITCH ELECTRICAL ROOM LVPDU BAE SYSTEM BATTERY SWITCH CHARGER DISCONNECT SWITCH 3 F M ESS QSB4.5 ISG100 24 24 HOUSE DISCONNECT SWITCH 24 HOUSE DISCONNECT SWITCH 24 VFD VFD MAPS MAPS ELECTRICAL ROOM 24VDC PANEL ELECTRICAL ROOM 24VDC PANEL LOADS LOADS 24 PILOT HOUSE NAV LIGHTS PANEL PILOT HOUSE BILGE PANELS LOADS 24 12 BILGE PUMPS 12 PILOT HOUSE 24VDC PANEL PILOT HOUSE 12VDC PANEL LOADS LOADS 12 BILGE PUMP RELAYS 24 BILGE PUMPS M GPM12 24VDC HOUSE BATTERY ELECTRICAL ROOM LVPDU 1 MPCS MPCS 1 TO HVPDU PORT 24VDC AMPS TOTAL EMERGENCY SHORE POWER AT SEA 181.33 A PORT BATTERY ROOM PANEL 24VDC LOADS DC LOADS CKT# CIRCUIT NAME 64.43 A AT SEA AT SEA 51.19 A EMERGENCY SHORE POWER STBD 24VDC AMPS TOTAL EMERGENCY SHORE POWER 142.38 A 64.52 A 31.75 A AT SEA EMERGENCY SHORE POWER STBD BATTERY ROOM PANEL 24VDC LOADS DC LOADS V QTY A W TTL A LF A LF A LF A CKT# CIRCUIT NAME V QTY A W TTL A LF A LF A LF A 1 ESS ROOM LIGHTS 24 2 0.67 16 1.3 0.60 0.8 0.60 0.8 0.60 0.8 1 ESS ROOM LIGHTS 24 2 0.67 16 1.3 0.60 0.8 0.60 0.8 0.60 0.8 1 ENGINE/JET/TANK/CHILLER LIGHTS 24 7 0.67 16 4.7 0.60 2.8 0.60 2.8 0.60 2.8 1 ENGINE/JET/TANK/CHILLER LIGHTS 24 7 0.67 16 4.7 0.60 2.8 0.60 2.8 0.60 2.8 1 VOID SPACE LIGHTS 24 3 0.42 10 1.3 0.60 0.8 0.00 0.0 0.60 0.8 1 VOID SPACE LIGHTS 24 3 0.42 10 1.25 0.60 0.8 0.00 0.0 0.60 0.8 2 GENERATOR INTAKE/EXHAUST 11" FAN 24 2 9.17 220 18.3 1.00 18.3 0.00 0.0 0.30 5.5 2 GENERATOR INTAKE/EXHAUST 11" FAN 24 2 9.17 220 18.3 1.00 18.3 0.00 0.0 0.30 5.5 4 BATTERY SPACE MINI FAN 24 1 8.33 200 8.3 1.00 8.3 0.00 0.0 0.60 5.0 4 BATTERY SPACE MINI FAN 24 1 8.33 200 8.3 1.00 8.3 0.00 0.0 0.60 5.0 5 LAZARETTE INTAKE & CHILLER INTAKE 9" FAN 24 2 5.00 120 10.0 0.85 8.5 0.00 0.0 0.00 0.0 5 LAZARETTE INTAKE & CHILLER INTAKE 9" FAN 24 2 5.00 120 10.0 0.85 8.5 0.00 0.0 0.00 0.0 8 PILOT HOUSE 24 1 35.8 858 35.8 0.80 28.6 0.70 25.0 0.40 14.3 8 PILOT HOUSE 24 1 35.8 858 35.8 0.00 0.0 0.70 25.0 0.00 0.0 6 PORT BILGE PUMP CONVERTER 24 3 10.42 250 31.3 0.10 3.1 0.40 12.5 0.10 3.1 6 STBD BILGE PUMP CONVERTER 24 3 10.42 250 31.3 0.10 3.1 0.40 12.5 0.10 3.1 7 ULTRAJET STEERING PRIMARY 24 1 10.42 250 10.4 1.00 10.4 1.00 10.4 0.50 5.2 7 ULTRAJET STEERING BACKUP 24 1 10.42 250 10.4 0.00 0.0 1.00 10.4 0.00 0.0 3 DAMPERS GENERATOR SPACE 24 2 0.3 7 0.6 1.00 0.6 0.30 0.2 1.00 0.6 3 DAMPERS GENERATOR SPACE 24 2 0.3 7 0.6 1.00 0.6 0.30 0.2 1.00 0.6 3 DAMPERS BATTERY ROOM 24 2 0.3 7 0.6 1.00 0.6 0.30 0.2 1.00 0.6 3 DAMPERS BATTERY ROOM 24 2 0.3 7 0.6 1.00 0.6 0.30 0.2 1.00 0.6 9 CARBON MONOXIDE MONITOR 24 1 0.1 2 0.1 1.00 0.1 1.00 0.1 1.00 0.1 9 CARBON MONOXIDE MONITOR 24 2 0.1 2 0.2 1.00 0.2 1.00 0.2 1.00 0.2 AMPS TOTAL 122.6 PORT LVPDU 24VDC LOADS DC LOADS CKT# CIRCUIT NAME 82.9 52.0 RUNNING STANDBY AMPS TOTAL 38.7 44.0 122.7 STBD LVPDU 24VDC LOADS DC LOADS V QTY A W TTL A LF A LF A CKT# CIRCUIT NAME 52.1 RUNNING 19.3 STANDBY V QTY A W TTL A LF A LF A 1 ESTOP 24 1 1 24 1.0 1.00 1.0 0.00 0.0 1 ESTOP 24 1 1 24 1.0 1.00 1.0 0.00 0.0 2 SCU 24 1 1 24 1.0 1.00 1.0 1.00 1.0 2 SCU 24 1 1 24 1.0 1.00 1.0 1.00 1.0 3 MPCS 24 1 7.4 177.6 7.4 1.00 7.4 0.60 4.4 3 MPCS 24 1 7.4 178 7.4 1.00 7.4 0.60 4.4 4 MAPS 24 1 1 24 1.0 1.00 1.0 0.00 0.0 4 MAPS 24 1 1 24 1.0 1.00 1.0 0.00 0.0 5 ESS KL30 24 1 1 24 1.0 1.00 1.0 1.00 1.0 5 ESS KL30 24 1 1 24 1.0 1.00 1.0 1.00 1.0 6 ESS KL30C 24 1 1 24 1.0 1.00 1.0 0.00 0.0 6 ESS KL30C 24 1 1 24 1.0 1.00 1.0 0.00 0.0 7 ESS KL15 24 1 1 24 1.0 1.00 1.0 0.00 0.0 7 ESS KL15 24 1 1 24 1.0 1.00 1.0 0.00 0.0 8 EDN1 24 1 1 24 1.0 1.00 1.0 1.00 1.0 8 EDN1 24 1 1 24 1.0 1.00 1.0 1.00 1.0 9 EDN2 24 1 1 24 1.0 1.00 1.0 1.00 1.0 9 EDN2 24 1 1 24 1.0 1.00 1.0 1.00 1.0 10 ENG IGN 24 1 1 24 1.0 1.00 1.0 0.00 0.0 10 ENG IGN 24 1 1 24 1.0 1.00 1.0 0.00 0.0 11 CIB 24 1 10 240 10.0 1.00 10.0 0.00 0.0 11 CIB 24 1 10 240 10.0 1.00 10.0 0.00 0.0 12 ECP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 12 ECP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 13 MCP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 13 MCP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 14 BCP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 14 BCP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 15 DIAG 24 1 1 24 1.0 1.00 1.0 0.00 0.0 15 DIAG 24 1 1 24 1.0 1.00 1.0 0.00 0.0 16 SEA 24 1 1 24 1.0 1.00 1.0 0.00 0.0 16 SEA 24 1 1 24 1.0 1.00 1.0 0.00 0.0 17 K1K1 24 1 1 24 1.0 1.00 1.0 0.00 0.0 17 K1K1 24 1 1 24 1.0 1.00 1.0 0.00 0.0 18 K1K2 24 1 1 24 1.0 1.00 1.0 0.00 0.0 18 K1K2 24 1 1 24 1.0 1.00 1.0 0.00 0.0 19 ISGP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 19 ISGP1 24 1 16 384 16.0 1.00 16.0 0.00 0.0 20 LVPDU1-R0 24 1 4 96 4.0 1.00 4.0 1.00 4.0 20 LVPDU1-R0 24 1 4 96 4.0 1.00 4.0 1.00 4.0 AMPS TOTAL FROM DC VOLTAGE DROP ANALYSIS TO 98.4 V-DROP [%] HOUSE BATTERY LVPDU BATTERY / MAPS BUSBAR 0.41 BUSBAR LVPDU 1.39 TOTAL 1.80 HOUSE BATTERY DC PANELBOARD PANEL BATTERY / MAPS BUSBAR 0.41 BUSBAR DC PANELBOARD 0.70 CHARGER BATTERY ESS ROOM BATTERY CHARGER BATTERY HOUSE BATTERY LIGHTS HOUSE BATTERY GENERAL LIGHTS J-BOX HOUSE BATTERY ESS ROOM, ENGINE/JET CHILLER AND VOID LIGHTS HOUSE BATTERY LOADS HOUSE BATTERY TOTAL 1.10 TOTAL 1.57 2.69 TOTAL 6.90 GENERATOR INTAKE/EXHAUST FAN TOTAL 6.39 HOUSE BATTERY GENERATOR SPACE & BATTERY ROOM DAMPERS TOTAL 1.94 HOUSE BATTERY BATTERY SPACE FAN TOTAL 5.31 HOUSE BATTERY LAZARETTE INTAKE & CHILLER INTAKE FANS TOTAL 3.20 HOUSE BATTERY BILGE PUMP DC CONVERTER TOTAL 7.34 HOUSE BATTERY PRIMARY ULTRAJET STEERING TOTAL 7.51 HOUSE BATTERY PILOT HOUSE TOTAL 2.53 HOUSE BATTERY GAS MONITOR DEVICE TOTAL 1.21 BILGE PUMP DC CONVERTER BILGE PUMP LOADS BILGE PUMP DC CONVERTER PILOT HOUSE BILGE PANEL TOTAL 4.26 BILGE PUMP DC CONVERTER BILGE PUMP TOTAL 6.52 98.4 12.4 AMPS TOTAL 98.4 98.4 12.4 CONDUCTOR SIZES DC-01 - 1 CIRCUIT WITH: (2) #8 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-02.1 / DC-02.2 - 1 CIRCUIT WITH: (2) #3/0 AWG ϕ CU, UL 1426, 90°C, 5 FT DC-03 - 1 CIRCUIT WITH: (2) #3/0 AWG ϕ CU, UL 1426, 90°C, 15 FT (1) #3 AWG GND CU, UL 1426, 90°C DC-04 - 1 CIRCUIT WITH: (2) #1 AWG ϕ CU, UL 1426, 90°C, 15 FT (1) #12 AWG GND CU, UL 1426, 90°C DC-05 - 1 CIRCUIT WITH: (2) #12 AWG ϕ CU, UL 1309, 90°C, 15 FT (1) #12 AWG GND CU, UL 1309, 90°C DC-06 - 2 CIRCUITS EACH WITH: (2) #12 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #12 AWG GND CU, UL 1309, 90°C DC-07 - 2 CIRCUITS EACH WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #14 AWG GND CU, UL 1309, 90°C DC-08 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 20 FT (1) #14 AWG GND CU, UL 1309, 90°C DC-09 - 2 CIRCUITS EACH WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 20 FT (1) #14 AWG GND CU, UL 1309, 90°C DC-10 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 25 FT (1) #10 AWG GND CU, UL 1309, 90°C DC-11 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1426, 90°C, 70 FT (1) #10 AWG GND CU, UL 1426, 90°C DC-12 - 1 CIRCUIT WITH: (2) #1/0 AWG ϕ CU, UL 1426, 90°C, 70 FT (1) #6 AWG GND CU, UL 1426, 90°C DC-13 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 10 FT (1) #14 AWG GND CU, UL 1309, 90°C DC-14 - 3 CIRCUITS EACH WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 40 FT (1) #14 AWG GND CU, UL 1309, 90°C DC-15 - 3 CIRCUITS EACH WITH: (3) #18 AWG ϕ CU, UL 1309, 90°C, 40 FT DC-16 - 3 CIRCUITS EACH WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 25 FT (1) #10 AWG GND CU, UL 1309, 90°C PILOTHOUSE FEEDER 24VDC AMPS TOTAL AT SEA EMERGENCY SHORE POWER 25.65 A PILOT HOUSE 24VDC - PANEL LOADS DC LOADS CIRCUIT NAME CKT# AT SEA 21.87 A 13.88 A EMERGENCY SHORE POWER V QTY A W TTL A LF A LF A LF A DC VOLTAGE DROP ANALYSIS TO V-DROP [%] 1 PASSENGER AREA LIGHTING 24 40 0.25 6 10.0 1.00 10.0 0.60 6.0 0.60 6.0 FROM 2 WHEELHOUSE LIGHTING 24 6 0.17 4 1.0 1.00 1.0 0.60 0.6 0.60 0.6 ELECTRICAL ROOM PILOT HOUSE BUSBAR 3 SPARE ELECTRICAL ROOM PILOT HOUSE 3.20 4 SPARE MTS APS 0.31 APS BAT+ TERMINAL BLOCK 0.79 5,6,7,8 GEN/BESS FAN CONTROL RELAYS 24 4 0.04 0.96 0.2 1.00 0.2 1.00 0.2 1.00 0.2 9 BOARDING AREA LIGHTS 24 2 1.00 24 2.0 0.60 1.2 1.00 2.0 1.00 2.0 10 DOCKING LIGHTS 24 2 2.33 56 4.7 0.60 2.8 1.00 4.7 0.60 2.8 ELECTRICAL ROOM PILOT HOUSE LOADS 11 NAV LIGHTS 24 1 1.49 35.7 1.5 0.60 0.9 1.00 1.5 0.00 0.0 ELECTRICAL ROOM AMPS TOTAL 19.3 16.1 PILOT HOUSE - 24VDC ALARM & CONTROL LOADS DC LOADS AT SEA 14.9 EMERGENCY 11.6 SHORE POWER TOTAL 4.29 DC DC CONVERTER TOTAL 6.28 DC DC CONVERTER 12V PANEL TOTAL 6.24 ELECTRICAL ROOM 24V PANEL LOADS ELECTRICAL ROOM 24V PANEL TOTAL 5.21 ELECTRICAL ROOM PASSENGER AREA LIGHTS TOTAL 9.97 ELECTRICAL ROOM WHEELHOUSE LIGHTS TOTAL 5.40 ELECTRICAL ROOM NAV LIGHTS PANEL LOADS ELECTRICAL ROOM NAV LIGHTS PANEL TOTAL 5.87 ELECTRICAL ROOM BOARDING AREA LIGHTS TOTAL 6.29 V QTY A W TTL A LF A LF A LF A ELECTRICAL ROOM DOCKING LIGHTS TOTAL 7.97 SHORE/GEN CONTACTORS 24 2 0.50 12 1.0 0.50 0.5 0.50 0.5 0.50 0.5 ELECTRICAL ROOM NAVIGATION LIGHTS (STERN LIGHT) TOTAL 6.92 MAIN/EMERGENCY CONTACTORS 24 2 0.50 12 1.0 0.50 0.5 0.50 0.5 0.50 0.5 ELECTRICAL ROOM NAVIGATION LIGHTS (ANCHOR LIGHT) TOTAL 6.92 ALARM PANEL 24 1 0.10 2.4 0.1 1.00 0.1 1.00 0.1 1.00 0.1 ELECTRICAL ROOM LOADS BESS TEMP MONITOR 24 1 0.04 0.96 0.0 1.00 0.0 1.00 0.0 1.00 0.0 ELECTRICAL ROOM BILGE WATER ALARM TOTAL 4.34 ELECTRICAL ROOM ESS ROOM TEMP ALARM TOTAL 4.34 ELECTRICAL ROOM LVPDU & DC PANEL REMOTE DISCONNECT SWITCH TOTAL 5.63 ELECTRICAL ROOM DC CONTROL LOADS ELECTRICAL ROOM STBD AC SELECTOR SWITCH TOTAL 5.55 ELECTRICAL ROOM PORT AC SELECTOR SWITCH TOTAL 5.55 ELECTRICAL ROOM SHORE POWER SELECTOR SWITCH TOTAL 5.55 ELECTRICAL ROOM BATTERY DISCONNECT SWITCH TOTAL 9.31 ELECTRICAL ROOM AC CONTROL LOADS FIRE PUMP LOCAL START REMOTE START TERMINAL TOTAL 0.03 FIRE PUMP CONTACTOR TERMINALS 2L2 AND 96 REMOTE STOP TERMINAL TOTAL 0.03 FIRE PUMP CONTACTOR TERMINALS 2T1 AND 6T3 RUN INDICATOR LIGHT TOTAL 0.03 CKT# CIRCUIT NAME AMPS TOTAL 2.1 1.1 PILOT HOUSE 12VDC LOADS DC LOADS CKT# CIRCUIT NAME AT SEA 1.1 1.1 EMERGENCY SHORE POWER V QTY A W TTL A LF A LF A LF A 1 HORN 12 1 0.83 9.96 0.8 0.30 0.2 1.00 0.8 0.00 0.0 2 RADIO 1 GX6000 12 1 5.5 66 5.5 1.00 5.5 0.50 2.8 0.10 0.6 3 RADIO 2 GX6000 12 1 5.5 66 5.5 0.10 0.6 0.50 2.8 0.10 0.6 4 RADAR/CHARTPLOTTER GARMIN 1243 12 1 5 60 5.0 1.00 5.0 1.00 5.0 0.10 0.5 5 LOUD HAILER VLH3000 12 1 7.5 90 7.5 0.50 3.8 0.00 0.0 0.10 0.8 6 PORT HIGH WATER ALARM 12 3 0.1 1.2 0.3 0.00 0.0 1.00 0.3 0.00 0.0 6 STBD HIGH WATER ALARM 12 3 0.1 1.2 0.3 0.00 0.0 0.00 0.0 0.00 0.0 7 SEARCH LIGHT 12 1 3.7 44.4 3.7 0.50 1.9 0.00 0.0 0.00 0.0 8 SPARE AMPS TOTAL 28.6 16.9 11.6 2.4 CONDUCTOR SIZES DC-01+ - 1 CIRCUIT WITH: (1) #4 AWG ϕ CU, UL 1309, 90°C, 5 FT DC-02 - 1 CIRCUIT WITH: (2) #4 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-03+ - 1 CIRCUIT WITH: (1) #8 AWG ϕ CU, UL 1309, 90°C, 5 FT DC-04 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 5 FT (1) #10 AWG GND CU, UL 1309, 90°C DC-05 - 1 CIRCUIT WITH: (2) #12 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-06 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 15 FT DC-07 - 1 CIRCUIT WITH: (2) #10 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-07.1 - 1 CIRCUIT WITH: (2) #12 AWG ϕ CU, UL 1309, 90°C, 60 FT DC-07.2 - 1 CIRCUIT WITH: (2) #12 AWG ϕ CU, UL 1309, 90°C, 15 FT DC-08 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-08.1 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 20 FT DC-11 - 1 CIRCUIT WITH: (3) #16 AWG ϕ CU, UL 1309, 90°C, 10 FT (1) #16 AWG GND CU, UL 1309, 90°C CW-01D - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 75 FT CW-02D - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 75 FT CW-03D - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 75 FT DC-08.2 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 20 FT CW-04D - 2 CIRCUITS EACH WITH: (3) #16 AWG ϕ CU, UL 1309, 90°C, 75 FT (1) #16 AWG GND CU, UL 1309, 90°C DC-08.3 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 50 FT CW-01A - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 85 FT DC-08.4 - 1 CIRCUIT WITH: (2) #14 AWG ϕ CU, UL 1309, 90°C, 50 FT DC-09 - 1 CIRCUIT WITH: (2) #18 AWG ϕ CU, UL 1309, 90°C, 10 FT DC-10 - 1 CIRCUIT WITH: (2) #18 AWG ϕ CU, UL 1309, 90°C, 10 FT CW-02A - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 85 FT CW-03A - 1 CIRCUIT WITH: (2) #16 AWG ϕ CU, UL 1309, 90°C, 85 FT (1) #16 AWG GND CU, UL 1309, 90°C HOUSE BATTERY TO BUSBAR DC FAULT CURRENT CALCS VALUES BATTERY SHORT CIRCUIT CURRENT (ISC1) UNIT 4400 A NO. BATTERIES IN PARALLEL (n) 1 BAE (MAPS) SHORT CIRCUIT CURRENT (ISC2) 250 A TOTAL SHORT CIRCUIT CURRENT ISC_total = (n x ISC1 + ISC2) 4650 A CONDUCTOR SIZE #3/0 AWG CONDUCTOR RESISTIVITY (R) 0.0000618 ohms/ft CONDUCTOR LENGTH (L) 20 ft CONDUCTORS PER PHASE (N) 1 SYSTEM VOLTAGE (V) 24 V AVAILABLE FAULT CURRENT (Isc_final) 3144.12 A RECOMMENDED AIC RATING MAIN AC SWITCHBOARD AC FAULT CURRENT CALCS SHORE TRANSFORMER FLA TRANSFORMER SECONDARY (ISC1) INVERTER (ISC1) HIGHER ISC1 (Isc_total) CONDUCTOR SIZE CONDUCTOR RESISTIVITY (R) 5000 AIC PILOT HOUSE EMERGENCY BATTERY TO BUSBAR VALUES UNIT Not Available A 22000 A DC FAULT CURRENT CALCS BATTERY SHORT CIRCUIT CURRENT (ISC1) NO. BATTERIES IN PARALLEL (n) VALUES UNIT 2622 A 1 64 A 22000 A #2 AWG 0.0001563 ohms/ft TOTAL SHORT CIRCUIT CURRENT ISC_total = (n x ISC1) CONDUCTOR SIZE CONDUCTOR RESISTIVITY (R) 2622 A #4 AWG 0.0002485 ohms/ft CONDUCTOR LENGTH (L) 40 ft CONDUCTOR LENGTH (L) 15 ft CONDUCTORS PER PHASE (N) 1 CONDUCTORS PER PHASE (N) 1 SYSTEM VOLTAGE (V) 24 V SYSTEM VOLTAGE (V) AVAILABLE FAULT CURRENT (I3Ø sc_final) RECOMMENDED AIC RATING 208 V 10254.73 A 10000 AIC AVAILABLE FAULT CURRENT (Isc_final) RECOMMENDED AIC RATING 1445.06 A 5000 AIC NO NO C NC FUSE NC NO C NC FUSE NO C NC FUSE NO C NC FUSE NO C NC FUSE NO C NC FUSE NO C NC FUSE NO C NC FUSE C NC FUSE NO C FUSE