MS_AIS Procedure Description The MS_AIS alarm indicates a multiplex section alarm, triggered when bits 6 to 8 of the K2 byte in three consecutive frames are "111". Impact on the System Services on the line port are interrupted. If configured with protection, protection switching is activated. Possible Causes • • The transmit unit of the peer site is malfunctioning. The receive unit of the local site is malfunctioning. Procedure Cause 1: The transmit unit of the peer site is faulty. • ➢ ➢ ➢ ➢ Replace the faulty board at the peer site, depending on the type of alarmreporting board: • If the line board reports the alarm, replace the line unit board at the peer end. • If the IF board reports the alarm, replace the IF board at the peer site. • After replacement, verify if the alarm is cleared. If the alarm clears, conclude alarm handling. If the alarm persists, proceed to the next step. • Replace the system control, switching, and timing board at the peer site if the alarm persists after the initial replacement. • After replacement, recheck for alarm clearance. If the alarm clears, conclude alarm handling. If the alarm persists, proceed to cause 2. Cause 2: The receive unit of the local site is faulty. • Replace the board reporting the alarm at the local site.