CLIENT
CONTRACTOR
DESIGN & DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS
FOR SALALAH TSE NETWORK
OCT 2022
RABI AL AWWAL 1444
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
Rev.: 00
Project Participants
Project Name
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
Client
Dhofar Integrated Services Company
Contractor
Galfar Engineering & Contracting SAOG
Contractor’s Consultant
AAW Consulting Engineers
Document Information
Document Title:
Calculation Sheet For Salalah TSE Pipelines
Doc Number:
02227-AAW- REP-00
Document Approval
Action
Name
Designation
Signature
Date
Prepared by:
Mai Ashraf
Design Engineer
MA
10.10.2022
Checked by:
Mohamed Hassan
Design Manager
MH
10.10.2022
Approved by:
Adel Sayed
Project Manager
AS
10.10.2022
Revision History
Rev.
Date
Purpose
Description
00
10.10.2022
For Review
Hydraulic Calculation
2/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
Rev.: 00
TABLE OF CONTENTS
1.
INTRODUCTION ................................................................................................................................................ 5
2.
SYSTEM TECHNICAL DATA ............................................................................................................................ 6
3.
Hydraulic Design Criteria ............................................................................................................................. 10
4.
HYDRAULIC ANALYSIS .................................................................................................................................. 11
5.
CONCLUSIONS................................................................................................................................................. 11
LIST OF APPENDIXES
APPENDIX-A - STEADY-STATE ANALYSIS RESULTS ................................................................................... 12
LIST OF FIGURES
Figure (1.1) General Layout for Dhofar Municipality TSE Pipelines ......................................................... 5
Figure (A.1) Hydraulic Profile for Main Pipeline (from Main PS to Sadaah PS1) .............................. 21
Figure (A.2) Hydraulic Profile for Main Pipeline (from Main PS to Itten PS1) ................................... 21
Figure (A.3) Hydraulic Profile for Main Pipeline (from Itten PS1 to Itten PS2).................................. 22
Figure (A.4) Hydraulic Profile for Main Pipeline (from Sadaah PS1 to Sadaah PS2) ....................... 22
Figure (4.1) The Node Diagram of Dhofar Municipality TSE Pipelines ............................................... 24
LIST OF TABLES
Table (2-1): Existing Pipelines Technical Data ................................................................................................. 6
Table (2-2): Proposed Pipelines Technical Data ............................................................................................. 6
Table (2-3): Pumps Technical Data ...................................................................................................................... 7
Table (2-4): Sumps Technical Data ...................................................................................................................... 7
Table (2-5): Connections Data ............................................................................................................................... 7
Table (A.1) Pipe Report .......................................................................................................................................... 13
Table (A.2) Junction Report .................................................................................................................................. 17
Table (A.3) Pump Report ....................................................................................................................................... 23
Table (A.4) FCV Report ........................................................................................................................................... 23
3/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
Rev.: 00
List of Abbreviations
DI
Ductile Iron
HDPE
High Density Polyethylene
uPVC
unplasticized Polyvinyl Chloride
FCV
Flow Control Valve
PS
Pump Station
TSE
Treated Sewage Effluent
List of Supporting Documents
Doc.
Title
Originator
Format
1
TSE EXISTING DESGIN DATA
DISC
CAD / PDF
2
Master Plan TSE-B
DISC
CAD
3
Final Design Report Drawings
Mott
Macdonald
PDF
4/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
1.
Rev.: 00
INTRODUCTION
Dhofar Integrated Services Company S.A.O.C (“Owner / DISC”) serves the people of Dhofar
governorate, covering electricity, water, and wastewater. The company aims to raise the
quality of these services and make them more efficient, reliable, and accessible. It is
expanding the service network by adopting strategies that reduce wastage, improve access,
and achieve customer satisfaction.
Therefore DISC contracted with Galfar Company to implement the proposed lines in Dhofar
municipality irrigation network, Galfar has contracted Consulting Engineers AAW & Partners
to prepare the Hydraulic Model of the existing pipelines and proposed pipelines and
detailed design drawings for proposed pipelines.
The objective of this report is to present the final results for the Dhofar Municipality TSE
network after incorporation the proposed pipelines to existing pipelines. Figure (1.1)
presents general layout for Dhofar Municipality TSE pipelines.
Figure (1.1) General Layout for Dhofar Municipality TSE Pipelines
5/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
2.
Rev.: 00
SYSTEM TECHNICAL DATA
The Dhofar Municipality TSE Network includes Pump Stations, Reservoirs and pipelines.

The technical data is listed in below Tables.

Project components are described in Dhofar Municipality TSE network Schematic.
Table (2-1): Existing Pipelines Technical Data
Pipeline No.
From
To
Nominal
Diameter
(mm)
Pipe Material
Length
(km)
1
Main PS
Hamdan Signal
630
HDPE
2.40
2
Hamdan Signal
MOD Signal
630
HDPE
4.80
3
MOD Signal
UAG R/A Signal
560
HDPE
6.00
4
Hamdan Signal
Itten PS1
500
HDPE
3.60
5
Itten PS1
Itten PS2
500 /200 /160
HDPE / uPVC
4.00
6
Itten PS2
Itten Park Tank
160
uPVC
3.00
7
UAG R/A Signal
Sadaah PS1
400
HDPE
1.60
8
Sadaah PS1
Sadaah PS2
250 /200
uPVC
5.00
9
Sadaah PS2
Hamrir Park Tank
160
uPVC
4.90
10
Tapping Point
Airport
500/355
HDPE
2.90
Table (2-2): Proposed Pipelines Technical Data
Pipeline No.
11
(Itten Line )
12
(Airport Line A)
13
(Saadah Line A)
14
(Saadah Line B)
From
To
Nominal
Diameter
(mm)
Pipe Material
Length
(km)
Tapping Point
Itten PS2
250
HDPE
2.90
Tapping Point
Tank
355
HDPE
4.00
Sadaah PS1
Sadaah PS2
400
HDPE
5.30
Sadaah PS2
End Point
400
HDPE
2.80
6/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
From
To
Nominal
Diameter
(mm)
Pipe Material
Length
(km)
Tapping Point
Tank
355
HDPE
0.10
Tapping Point
End Point
125
HDPE
0.13
Pipeline No.
15
(Airport Line B)
16
(Municipality
Line)
Rev.: 00
Table (2-3): Pumps Technical Data
PS Name
No. of
Pumps
Flow each
(m³/h)
Head (m)
Inlet Pipe
Diameter (mm)
Outlet Pipe
Diameter (mm)
Main PS
4
900
50
600
600
Itten PS1
4
300
50
400
400
Itten PS2
2
60
65
150
150
Sadaah PS1
3
120
65
250
250
Sadaah PS2
2
60
65
200
200
Table (2-4): Sumps Technical Data
PS Name
Volume (m³)
Elevation (m)
Main PS
5625
19.80
Itten PS1
50
26.75
Itten PS2
25
51.30
Sadaah PS1
50
13.70
Sadaah PS2
25
40.40
Table (2-5): Connections Data
Connection No.
Target Demand
(m³/h)
Location
Status
S2
25
Inside Ittin -1 P.S
From Data / Existing branch
S3
25
Crossing near Mc Donald
Al Wadi
Assumed / Existing branch
7/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR SALALAH TSE NETWORK
Rev.: 00
Connection No.
Target Demand
(m³/h)
Location
Status
S4
30
Inside Football Stadium
Parking
From Data / Existing branch
S5
30
Crossing Near Park
From Data / Existing branch
S6
30
Before MOD Signal near
Ministry of Heritage &
Culture
From Data / Existing branch
S7
30
After MOD Signal near KFC
From Data / Existing branch
S8
30
Old Airport
From Data / Existing branch
S9
30
Sahwa Tower
Assumed / Existing branch
S10
30
Below Flyover corner of
Saadah Signal
From Data / Existing branch
S10A
300
Near Dhofar Cattle Feed
From Data / Existing branch
S11
30
Near Dhofar Cattle Feed
From Data / Existing branch
S12
137
Near Ittin Roundabout
From Data / Proposed branch
S12A
30
-
From Data / Existing branch
S13
30
-
From Data / Existing branch
S14
20
Opp Salalah Technical
College
Assumed / Existing branch
S15
20
Near Rop Roundabout
Assumed / Existing branch
S16
20
-
Assumed / Existing branch
S17
10
Before New Airport
From Data / Existing branch
S18
60
End Itten Pipeline
Assumed / Existing Tank
S19
10
End Sadaah Pipeline
Assumed / Existing Tank
S20
20
Dhofar University
Roundabout
Assumed / Existing branch
S21
30
End Sadaah Line B
Assumed / Future Connection
8/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE NETWORK
DHOFAR TSE NETWORK SCHEMATIC
Itten Park Tank
S18= 60 m³/hr
Line 14
HDPE - 400 mm
Future Connection
S21 = 30 m³/hr
Feeding Point = S
Target Flow = - m³/hr
S12-1
70 m³/hr
SADAAH
PS2
Line 12
HDPE - 355 mm
Line 10
HDPE – 500/355 mm
S15
20 m³/hr
S12-2
70 m³/hr
S14
20 m³/hr
S17
10 m³/hr
PS
Line 1
HDPE - 630 mm
S3
30 m³/hr
S4
30 m³/hr
S5
30 m³/hr
S7
30 m³/hr
S6
30 m³/hr
MOD
Signal
Line 2
HDPE - 630 mm
9/24
S8 & S9
30 m³/hr
Line 3
HDPE - 560 mm
Line 7
Line 4
HDPE - 500 mm
Hamdan
Signal
S11
30 m³/hr
uPVC - 400 mm
SADAAH
PS1
Line 16
HDPE - 125 mm
Main
Line 8
uPVC – 250 :200 mm
Line 15
HDPE - 355 mm
S16
20 m³/hr
Itten PS1
S2
25 m³/hr
Line 9
uPVC – 200 :160 mm
Proposed Pipeline
Line 5
uPVC – 200/ 160 mm
Line 5
HDPE - 500 mm
Salalah Tank
S20 = 20 m³/hr
Line 13
HDPE - 400 mm
Line6
uPVC - 160 mm
Existing Pipeline
S13
30 m³/hr
Line 11
HDPE - 250mm
Hamrir Park Tank
S19 = 10 m³/hr
Legend
Itten PS2
S12A
30 m³/hr
Rev.: 00
UAG R/A
Signal
S10A
300 m³/hr
S10
30 m³/hr
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
3.
Rev.: 00
Hydraulic Design Criteria
Network analysis shall be undertaken using advanced computer software (WaterCAD
Connect edition update 3). Transmission lines will be designed using Hazen-Williams
formula for its proven accuracy and adaptability over a range of pipe sizes. This formula
can be expressed as:
 L
V  0.355CD 0.63 H
0.54
Where:
-
V
=
Average velocity of flow (m/s)
-
C
=
Friction coefficient, depending on pipe material
-
D =
Internal pipe diameter (m)
-
H =
Friction head loss (m)
-
L
Pipe length (m)
-
Maximum flow velocity
= 1.5 m/s
-
Maximum hydraulic gradient slope
= 10.0 m/km
-
Minimum residual pressure along the pipeline
= 1.0 bar
-
Flow control valves (FCV) are used to achieve required flow.
-
Hazen-Williams coefficient C for pipe = 130 including minor losses.
=
10/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
4.
Rev.: 00
HYDRAULIC ANALYSIS
The Dhofar TSE transmission pipelines have been simulated using WaterCAD Connect
edition update 3 as follows:
-
Routing of TSE pipelines (Existing and Proposed) are taken from Master Plan Drawing
provided by DISC.
-
TSE pipelines are modelled as pipes with lengths and diameters. Junctions are added
along the pipeline at approx. 500 m spacing to simulate the pipelines profile.
-
The elevations are taken from available topographical survey for proposed pipelines
and from as built drawings and google earth for existing pipelines, pump stations
and reservoirs.
-
Pump stations are modelled as reservoir and a pump with required elevations.
-
Pump curves are simulated as one-point curve with duty flow and head. One pump
is assumed in operation in each pump station.
-
Flow control valves (FCV) are used at inlets to pump station sumps to achieve required
flows.
-
Figure (4.1) shows the node diagram of the simulated pipelines.
Steady-state analysis is carried out for TSE transmission pipelines. Appendix A presents
hydraulic analysis results.
5.
CONCLUSIONS
From the hydraulic analysis (highlighted in green color) it can be concluded that:
 There are negative pressure at the end of line 6 and line 7.
11/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
APPENDIX-A
STEADY-STATE ANALYSIS RESULTS
12/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Table (A.1) Pipe Report
Label
Length (m)
Material
P-1
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
P2-7
P2-8
P2-9
P2-10
P2-11
P2-12
P2-13
P2-14
P3-1
P3-2
P3-3
P3-4
P3-5
P3-6
P3-7
P3-8
P3-9
P3-10
P3-11
P3-12
P3-13
P3-14
P3-15
P3-16
P4-1
P4-2
P4-3
P4-4
P4-5
68
500
500
500
500
365
9
501
500
500
393
107
500
392
108
265
235
500
305
195
342
158
40
460
500
500
474
26
159
341
500
500
500
500
500
500
410
4
8
5
500
500
uPVC
HDPE
HDPE
HDPE
HDPE
HDPE
DI
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
DI
DI
DI
HDPE
HDPE
Inner
Diameter
(mm)
170.2
515.6
515.6
515.6
515.6
515.6
600
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
515.6
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
458.4
400
400
400
388.4
388.4
Flow
(m³/h)
Velocity
(m/s)
30
867
867
867
867
867
867
542
542
542
542
512
512
512
482
482
452
452
452
422
422
422
422
392
392
392
392
392
392
362
362
362
362
362
362
362
362
300
300
270
325
325
0.37
1.15
1.15
1.15
1.15
1.15
0.85
0.72
0.72
0.72
0.72
0.68
0.68
0.68
0.64
0.64
0.6
0.6
0.6
0.56
0.56
0.71
0.71
0.66
0.66
0.66
0.66
0.66
0.66
0.61
0.61
0.61
0.61
0.61
0.61
0.61
0.61
0.66
0.66
0.6
0.76
0.76
Headloss
Gradient
(m/km)
1.019
2.341
2.341
2.341
2.341
2.341
1.119
0.981
0.981
0.981
0.981
0.883
0.883
0.883
0.79
0.79
0.701
0.701
0.701
0.617
0.617
1.095
1.095
0.955
0.955
0.955
0.955
0.955
0.955
0.824
0.824
0.824
0.824
0.824
0.824
0.824
0.824
1.129
1.129
0.929
1.511
1.511
13/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Label
Length (m)
Material
P4-6
P4-7
P4-8
P4-9
P4-10
P4-11
P5-1
P5-2
P5-3
P5-4
P5-5
P5-6
P5-7
P5-8
P5-9
P5-10
P5-11
P5-12
P5-13
P5-14
P5-15
P5-16
P5-17
P6-1
P6-2
P6-3
P6-4
P6-5
P6-6
P6-7
P7-1
P7-2
P7-3
P7-4
P7-5
P7-6
P7-7
P7-8
P7-9
P8-1
P8-2
P8-3
P8-4
P8-5
500
500
500
500
500
57
9
7
4
22
500
88
342
500
81
411
500
500
500
412
88
9
8
500
500
500
500
500
500
38
18
7
11
10
504
500
139
25
374
4
358
500
171
329
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
uPVC
uPVC
DI
DI
HDPE
uPVC
uPVC
HDPE
HDPE
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
DI
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
DI
DI
DI
DI
uPVC
uPVC
uPVC
uPVC
uPVC
DI
uPVC
uPVC
uPVC
uPVC
Inner
Diameter
(mm)
388.4
388.4
388.4
388.4
388.4
388.4
150
150
150
400
388.4
136.2
136.2
388.4
388.4
170.2
170.2
170.2
170.2
170.2
136.2
150
170.2
136.2
136.2
136.2
136.2
136.2
136.2
136.2
250
250
250
250
212.8
212.8
212.8
212.8
212.8
200
212.8
212.8
212.8
170.2
Flow
(m³/h)
Velocity
(m/s)
325
325
325
325
325
300
60
60
60
270
270
(N/A)
(N/A)
270
270
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
60
120
60
60
60
60
60
60
60
120
120
2
2
332
332
302
300
302
60
(N/A)
(N/A)
(N/A)
(N/A)
0.76
0.76
0.76
0.76
0.76
0.7
0.94
0.94
0.94
0.6
0.63
(N/A)
(N/A)
0.63
0.63
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.94
1.47
1.14
1.14
1.14
1.14
1.14
1.14
1.14
0.68
0.68
0.01
0.01
2.59
2.59
2.36
2.34
2.36
0.53
(N/A)
(N/A)
(N/A)
(N/A)
Rev.: 00
Headloss
Gradient
(m/km)
1.511
1.511
1.511
1.511
1.511
1.303
6.81
6.81
6.81
0.929
1.072
(N/A)
(N/A)
1.072
1.072
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
6.809
13.285
10.897
10.897
10.897
10.897
10.897
10.897
10.897
2.042
2.042
0.001
0.001
29.499
29.499
24.756
24.424
24.756
1.677
(N/A)
(N/A)
(N/A)
(N/A)
14/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Label
Length (m)
Material
P8-6
P8-7
P8-8
P8-9
P8-10
P8-11
P8-12
P8-13
P8-14
P8-15
P8-16
P8-17
P8-18
P8-19
P9-1
P9-2
P9-3
P9-4
P9-5
P9-7
P9-8
P9-9
P9-10
P9-11
P9-12
P9-13
P9-14
P10-1
P10-2
P10-3
P10-4
P10-5
P10-6
P10-7
P10-8
P10-9
P11-1
P11-2
P11-3
P11-4
P11-5
P11-6
P11-7
500
71
22
8
381
500
211
289
500
500
500
304
196
29
175
228
197
500
394
288
500
500
97
500
500
500
500
500
500
413
87
500
412
88
273
254
2
502
500
500
500
500
340
uPVC
uPVC
DI
DI
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
DI
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
uPVC
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
Inner
Diameter
(mm)
170.2
170.2
200
200
212.8
212.8
212.8
212.8
212.8
212.8
212.8
212.8
212.8
200
136.2
136.2
170.2
136.2
136.2
136.2
136.2
136.2
136.2
136.2
136.2
136.2
136.2
388.4
388.4
388.4
290.6
290.6
290.6
290.6
290.6
290.6
130.8
204.6
204.6
204.6
204.6
204.6
204.6
Flow
(m³/h)
Velocity
(m/s)
(N/A)
(N/A)
60
60
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
60
30
10
(N/A)
10
10
(N/A)
(N/A)
(N/A)
(N/A)
10
10
10
10
150
150
150
140
140
140
70
70
(N/A)
30
120
120
120
120
120
90
(N/A)
(N/A)
0.53
0.53
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.53
0.57
0.19
(N/A)
0.19
0.19
(N/A)
(N/A)
(N/A)
(N/A)
0.19
0.19
0.19
0.19
0.35
0.35
0.35
0.59
0.59
0.59
0.29
0.29
(N/A)
0.62
1.01
1.01
1.01
1.01
1.01
0.76
Rev.: 00
Headloss
Gradient
(m/km)
(N/A)
(N/A)
1.677
1.677
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
1.677
3.019
0.395
(N/A)
0.395
0.395
(N/A)
(N/A)
(N/A)
(N/A)
0.395
0.395
0.395
0.395
0.361
0.361
0.361
1.305
1.305
1.305
0.362
0.362
(N/A)
3.675
5.42
5.42
5.42
5.42
5.42
3.181
15/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Label
Length (m)
Material
P12-1
P12-2
P12-3
P12-4
P12-5
P12-6
P12-7
P12-8
P13-1
P13-2
P13-3
P13-4
P13-5
P13-6
P13-7
P13-8
P13-9
P13-10
P13-11
P13-12
P13-13
P13-14
P13-15
P13-16
P13-17
P14-1
P14-2
P14-3
P14-4
P14-5
P14-6
P14-7
P15-1
P16-1
500
500
500
500
500
500
500
500
51
79
30
484
500
461
39
500
500
500
500
30
470
399
101
500
253
482
500
500
146
354
500
311
100
126
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
Inner
Diameter
(mm)
290.6
290.6
290.6
290.6
290.6
290.6
290.6
290.6
163.6
163.6
163.6
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
326.8
290.6
102.2
Flow
(m³/h)
Velocity
(m/s)
70
70
70
70
70
70
70
70
20
20
20
120
120
120
100
100
100
100
100
100
80
80
60
60
60
60
60
60
60
30
30
30
70
0
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.26
0.26
0.26
0.4
0.4
0.4
0.33
0.33
0.33
0.33
0.33
0.33
0.26
0.26
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.1
0.1
0.1
0.29
0
Rev.: 00
Headloss
Gradient
(m/km)
0.362
0.362
0.362
0.362
0.362
0.362
0.362
0.362
0.583
0.583
0.583
0.554
0.554
0.554
0.395
0.395
0.395
0.395
0.395
0.395
0.261
0.261
0.153
0.153
0.153
0.153
0.153
0.153
0.153
0.042
0.042
0.042
0.362
0
16/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Table (A.2) Junction Report
Label
Elevation (m)
Demand (m³/h)
J1-1
13
0
Hydraulic Grade
(m)
65.45
J1-2
19
0
69.81
4.97
J1-3
15
0
68.64
5.25
J1-4
13
0
67.47
5.33
Pressure (Bar)
5.13
J1-5
13
0
66.3
5.22
J2-1
12.07
0
61.35
4.82
J2-2
11.4
0
64.96
5.24
J2-3
11.5
0
64.46
5.18
J2-4
14
0
63.97
4.89
J2-5
13.74
0
63.49
4.87
J2-6
12
0
63.05
5
J2-7
12.25
0
62.62
4.93
J2-8
13.1
0
62.25
4.81
J2-9
11.95
0
61.9
4.89
J2-10
10.4
0
61.56
5.01
J3-1
10
0
56.02
4.5
J3-2
9.15
0
59.29
4.91
J3-3
11.2
0
61.18
4.89
J3-4
10
0
60.7
4.96
J3-5
8.61
0
60.22
5.05
J3-6
10
0
59.74
4.87
J3-7
9.1
0
59.26
4.91
J3-8
8.9
0
58.83
4.89
J3-9
8.43
0
58.42
4.89
J3-10
4.1
0
58.01
5.28
J3-11
8.04
0
57.59
4.85
J3-12
8.1
0
57.18
4.8
J3-13
7.78
0
56.77
4.79
J3-14
7.7
0
56.36
4.76
J4-1
28
0
60.08
3.14
J4-2
13.2
0
64.69
5.04
J4-3
14.4
0
63.94
4.85
J4-4
16.35
0
63.18
4.58
J4-5
19.9
0
62.42
4.16
J4-6
23
0
61.67
3.78
J4-7
26
0
60.91
3.42
J5-1
31.2
0
78.73
4.65
J5-2
28
0
79.89
5.08
J5-3
46.2
(N/A)
(N/A)
(N/A)
17/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Label
Elevation (m)
Demand (m³/h)
J5-4
28
0
Hydraulic Grade
(m)
79.36
Rev.: 00
Pressure (Bar)
5.03
J5-5
30
0
78.82
4.78
J5-6
32.01
(N/A)
(N/A)
(N/A)
J5-7
33.69
(N/A)
(N/A)
(N/A)
J5-8
37.28
(N/A)
(N/A)
(N/A)
J5-9
41.39
(N/A)
(N/A)
(N/A)
J5-10
47.36
(N/A)
(N/A)
(N/A)
J5-11
30.38
0
78.63
4.72
J6-1
52
0
116.21
6.28
J6-2
56.8
0
110.77
5.28
J6-3
63.67
0
105.32
4.08
J6-4
69.6
0
99.87
2.96
J6-5
75.6
0
94.42
1.84
J6-6
88.36
0
88.97
0.06
J6-7
98
0
83.52
-1.42
J7-1
15
0
13.7
-0.13
J7-2
14.04
0
22.95
0.87
J7-3
11.05
0
41.15
2.95
J8-1
14.04
(N/A)
(N/A)
(N/A)
J8-2
14.54
0
78.65
6.27
J8-3
41.68
0
76.67
3.42
J8-4
15.82
(N/A)
(N/A)
(N/A)
J8-5
18.09
(N/A)
(N/A)
(N/A)
J8-6
20.73
(N/A)
(N/A)
(N/A)
J8-7
23.12
(N/A)
(N/A)
(N/A)
J8-8
24.95
(N/A)
(N/A)
(N/A)
J8-9
28.17
(N/A)
(N/A)
(N/A)
J8-10
30.37
(N/A)
(N/A)
(N/A)
J8-11
35.18
(N/A)
(N/A)
(N/A)
J8-12
39.64
(N/A)
(N/A)
(N/A)
J8-13
42.36
(N/A)
(N/A)
(N/A)
J9-1
41.39
0
105.35
6.26
J9-2
44.17
(N/A)
(N/A)
(N/A)
J9-3
45.98
(N/A)
(N/A)
(N/A)
J9-4
49.09
(N/A)
(N/A)
(N/A)
J9-5
51.14
(N/A)
(N/A)
(N/A)
J9-6
51.06
0
104.48
5.23
J9-7
50.5
0
104.28
5.26
J9-8
48.4
0
104.08
5.45
J9-9
55.2
0
103.88
4.76
J9-10
72.5
0
103.69
3.05
J9-11
77.8
0
103.49
2.51
18/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Label
Elevation (m)
Demand (m³/h)
J10-1
39.4
0
Hydraulic Grade
(m)
76.92
J10-2
31.18
0
78.55
4.64
J10-3
31.82
0
78.37
4.56
J10-4
35.05
0
78.11
4.21
J10-5
37.83
0
77.46
3.88
J10-6
39.1
0
76.89
3.7
J10-7
37.49
0
76.79
3.85
J11-1
30.68
0
75.91
4.43
J11-2
33.91
0
73.2
3.85
J11-3
37.79
0
70.49
3.2
J11-4
42.48
0
67.78
2.48
J11-5
49
0
65.07
1.57
J12-1
38.55
0
76.61
3.72
J12-2
40.73
0
76.43
3.49
J12-3
39.63
0
76.25
3.58
J12-4
42.02
0
76.07
3.33
J12-5
39.65
0
75.88
3.55
J12-6
34.23
0
75.7
4.06
Pressure (Bar)
3.67
J12-7
28.1
0
75.52
4.64
J13-1
19.03
0
77.85
5.76
J13-2
30.32
0
77.03
4.57
J13-3
38.02
0
76.8
3.8
J13-4
14.23
0
78.38
6.28
J13-5
16.62
0
78.1
6.02
J13-6
21.98
0
77.64
5.45
J13-7
24.23
0
77.44
5.21
J13-8
25.91
0
77.24
5.02
J13-9
30.23
0
77.04
4.58
J13-10
31.83
0
76.91
4.41
J13-11
39.59
0
76.79
3.64
J13-12
39.26
0
76.71
3.67
J14-1
51.06
0
105.1
5.29
J14-2
45.63
0
105.27
5.84
J14-3
47.93
0
105.19
5.6
J14-4
50.6
0
105.12
5.34
J14-5
52.18
0
105.08
5.18
J14-6
50.17
0
105.06
5.37
J16-1
10
0
59.29
4.82
S2
28
25
60.16
3.15
S3
13.7
30
63.59
4.88
S4
12.1
30
62.71
4.95
19/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Hydraulic Grade
(m)
62.41
Rev.: 00
Label
Elevation (m)
Demand (m³/h)
Pressure (Bar)
S5
12.5
30
S6
10.1
30
61.68
5.05
S7
12
30
61.13
4.81
S 8-9
8.8
30
59.11
4.92
S 10
10
30
55.95
4.5
S 10A
15
300
13.1
-0.19
4.88
S 11
14
30
26.4
1.21
S 12A
52.5
30
63.99
1.12
S 13
49.04
30
65.06
1.57
S 14
19.6
20
77.83
5.7
S 15
29.43
20
76.98
4.65
S 16
37.45
20
76.77
3.85
S 17
34.9
10
78.22
4.24
S12
38
(N/A)
(N/A)
(N/A)
S12-1
40.02
70
76.88
3.61
S12-2
24.65
70
75.34
4.96
S18
98.3
60
83.11
-1.49
S19
88.5
10
103.33
1.45
S20
51.1
20
104.57
5.23
S21
48.54
30
105.05
5.53
20/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Main PS
Sadaah PS1
Figure (A.1) Hydraulic Profile for Main Pipeline (from Main PS to Sadaah PS1)
Itten PS1
Main PS
Figure (A.2) Hydraulic Profile for Main Pipeline (from Main PS to Itten PS1)
21/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Itten PS2
Itten PS1
Figure (A.3) Hydraulic Profile for Main Pipeline (from Itten PS1 to Itten PS2)
Sadaah PS2
Sadaah PS1
Figure (A.4) Hydraulic Profile for Main Pipeline (from Sadaah PS1 to Sadaah PS2)
22/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE
NETWORK
Rev.: 00
Table (A.3) Pump Report
Label
Elevation
(m)
Flow (Design)
(m³/h)
Head
(Design) (m)
MAIN PS
ITTEN PS1
ITTEN PS2
19.50
26.50
50.70
900
300
60
50.00
50.00
65.00
Flow
(Actual)
(m³/h)
867
270
60
SADAAH PS1
13.20
120
65.00
120
65.00
SADAAH PS2
40.10
60
65.00
60
65.00
Head (Actual)
(m)
51.19
53.17
65.00
Table (A.4) FCV Report
Label
Elevation (m)
Diameter (mm)
FCV-Itten 1
28.00
400.0
Flow Setting
(m³/h)
300
FCV-Itten 2
52.78
150.0
60
FCV-Sadaah 1
15.00
250.0
120
FCV-Sadaah 2
41.69
200.0
60
Flow (Actual)
(m³/h)
300
60
2
60
23/24
DESIGN &DETAILED ENGINEERING W.R.T
O&M OF SALALAH WASTE WATER SYSTEM
HYDRAULIC CALCULATIONS FOR DHOFAR MUNICIPALITY TSE NETWORK
Figure (4.1) The Node Diagram of Dhofar Municipality TSE Pipelines
24/24