Uploaded by marene077

SITE INSTALLATION PLAN - INSTALLATION OF UNICEM MASTER FLOWMETER PROJECT - FINAL (1)

advertisement
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
SITE INSTALLATION PLAN
FOR
INSTALLATION OF UNICEM MASTER FLOWMETER PROJECT
ACCUGAS – A SAVANNAH ENERGY COMPANY
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
CONTENTS
1
INTRODUCTION .............................................................................................................................. 3
2
PURPOSE ........................................................................................................................................ 3
3
SITE INSTALLATION STRATEGY ....................................................................................................... 3
4
5
3.1
Site Mobilisation...................................................................................................................... 3
3.2
Planned Installation Method................................................................................................... 3
3.3
Proposed Work Breakdown Sequence (WBS) ......................................................................... 3
RESOURCE REQUIREMENT ............................................................................................................. 4
4.1
Site Project Execution Personnel ............................................................................................ 4
4.2
Installation Materials & Consumables .................................................................................... 5
4.3
Tools & Equipment .................................................................................................................. 9
4.4
Logistics & Other Services ..................................................................................................... 13
POSSIBLE CHALLENGES AND PROPOSED MITIGATIVE ACTIONS.................................................. 14
Page 2 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
1 INTRODUCTION
Accugas a member of Savannah Energy owner and operator of the Uquo Central Processing Facility
(UCPF) at Esit Eket LGA of Akwa Ibom State, Nigeria wishes to carry out the Installation and
Commissioning of a Master flowmeter and Ancillary work at UNICEM Gas Receiving Facility in
Calabar. The purpose of this Master flowmeter is to provide a highly accurate meter used for checking
the accuracy and calibration of duty meters in use in their normal operating position as well as
minimize fiscal risk.
Engineering Automation Technology Limited was contracted by Accugas to prefabricate the spools
and carry out installation of the spools, valves, and the flowmeter on site.
2 PURPOSE
The purpose of this document is to outlined the planned execution strategy for the site installation
(shutdown) phase of the INSTALLATION OF UNICEM MASTER FLOWMETER PROJECT. This document
contains the proposed requirement necessary for a successful execution of this phase of the project.
3
SITE INSTALLATION STRATEGY
3.1 Site Mobilisation
Mobilisation will commence from Sunday, 05 April 2024 through Tuesday, 07 April 2024. The first
batch of materials, tools and equipment will leave EATL Fabrication Yard, Eket, for Calabar on Sunday,
05 April 2024; the second batch of items will leave on Tuesday, 07 April 2024.
3.2
Planned Installation Method
• Spading and Nitrogen Purging
• Decommissioning of existing spools and Installation of fabricated spools and valves.
• Decommissioning, cutting and welding of one joint on 18'' piping spool, NDT and reinstallation
of modified spools
• Flange management (Torquing of the flanges to required torque values).
3.3 Proposed Work Breakdown Sequence (WBS)
This shutdown phase of the project execution – from mobilisation to demobilisation – has been
scheduled for 7 days in line with the WBS outlined below.
Table 3-1: Site Installation Work Breakdown Sequence
INSTALLATION OF UNICEM MASTER FLOW METER
Mobilisation to Site
Carry out pre-mob inspection
Mobilise materials, equipment, and tools to Client's facility at Calabar
Page 3 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
Shutdown Activities / Site Installation
Obtain necessary PTW
Mobilize all prefab spools, pipe support, materials, tools, personnel and equipment to the field
Stage Equipment at Site
On-site Piping Work
Decommission the existing sections of the piping to be modified (String 2A, 2B & 2C)
Decommission the passing 8’’ x 300# ball valve upstream the filter on string 2A, the failed / passing 8’’ x 300#
ball valves upstream the filter separators on string 2B & 2C, and the 14’’ pipe spools downstream the proposed
master meter on string 2B
Clean the flange faces and install the pipe spools on the pipe supports
Install the leak-tested 6Nos ball valves and one new master flowmeter, and complete the tie-in works to the
existing piping / headers within the PRMS skid
Install all leak-tested ball valves on string 2B & 2C
Install 3Nos of 8’’x 300# and 3Nos of 14’’ x 150# Spectacle blinds
Carry out leak test and Nitrogen purging of the piping system
Carry out cold cutting and pipe / fitting ends preparation on the 18’’ weld joint.
Carry out welding on the 18’’ weld joint.
Carry out 200% NDT (Golden joint inspection) on the 18’’ weld joint.
Flange management-Torquing of flanges to required torque values
Instrumentation and Electrical Work
Disconnect all electrical connections on the existing turbine flowmeter 2A
Disconnect associated instrumentation connections on the skid piping
Disconnect associated instrumentation connections on existing 14’’ pipe spool of string 2B, where modification
work is to be done
Hook-up / Tie-in / integrate all required instrumentation work on the new master flowmeter
Re-connect all disconnected instrumentations on the headers
Re-connect all disconnected instrumentations after completing the prefab spool installation and tie-in on
string 2B
Reconnect the previously disconnected electrical connections
Housekeeping
Demobilise Personnel, equipment and tools from client site
4
RESOURCE REQUIREMENT
4.1 Site Project Execution Personnel
Table 4-1: Site Installation Project Personnel
S/N
Personnel
Role
Medical
Remark
1.
Elvis Ikenna
Construction Engineer
Yes
Available
2.
Awak Inimbom
Fitter/Torque Operator
Yes
Available
3.
Friday Robinson
Fitter/Torque Operator
Yes
Available
Page 4 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
4.
Emakpo Godspower
Fitter
Yes
Available
5.
Yokri Godspower
Welder
Yes
Available
6.
Ebong Essien
Welder/Torque Operator
Yes
Available
7.
Emmanuel Udo
Safety Officer/Permit Holder
Yes
Available
8.
Sam Ubong
Self-loader Operator
Yes
Available
9.
Etim Sunday
Rigger
Yes
Available
10.
Marvellous Chukwuemerie
Project QAQC
Yes
Available
11.
Ikechukwu Umezulike
Instrument Tech
Yes
Available
12.
Chinedu Nzete
Instrument Tech
Yes
Available
13.
Udeme Ekpenyong
Torque Operator
Yes
Available
14.
Francis Asuah
Driver 1 - Bus
Yes
Available
15.
James Iniobong
Pipe Fitter
Yes
Available
16.
Unyime Ezekiel
Driver 2 - Hilux
Yes
Available
17.
NDT Technician
Cyril Ntiero
N/A
Subcontractor
18.
NDT Technician
Sunday Daniel
N/A
Subcontractor
19.
NDT Technician
Aniedi Tom
N/A
Subcontractor
20.
NDT Technician
Dan Egbo-Egbo
N/A
Subcontractor
4.2 Installation Materials & Consumables
Table 4-2: List of Installation Materials and Consumables
S/N
Description
UoM
Qty
Available
Remarks
1.
Fabricated Spools
Spools
5
Yes
Available
2.
Gasket - 1-1/2" SPW CL300, SS-304 Winding Graphite ea
Filled, SS-304 Inner Ring, CS Outer Ring, 4.5mm Thick,
DIM to ASME B16.20 and ASME B16.5
Gasket - 8" SPW CL300, SS-304 Winding Graphite Filled, ea
SS-304 Inner Ring, CS Outer Ring, 4.5mm Thick, DIM to
ASME B16.20 and ASME B16.5
8
Yes
Available
32
Yes
Available
3.
Page 5 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
4.
ea
6
Yes
Available
ea
2
Yes
Available
ea
11
Yes
Available
7.
Gasket - 6" SPW CL300, SS-304 Winding Graphite Filled,
SS-304 Inner Ring, CS Outer Ring, 4.5mm Thick, DIM to
ASME B16.20 and ASME B16.6
Gasket - 12" SPW CL300, SS-304 Winding Graphite
Filled, SS-304 Inner Ring, CS Outer Ring, 4.5mm Thick,
DIM to ASME B16.20 and ASME B16.6
Gasket - 14" SPW CL150, SS-304 Winding Graphite
Filled, SS-304 Inner Ring, CS Outer Ring, 4.5mm Thick,
DIM to ASME B16.20 and ASME B16.5
Flange Blind - 14" RF, CL150, ASTM A105
ea
3
Yes
Available
8.
Flange Blind - 6" RF, CL300, ASTM A104
ea
2
Yes
Available
9.
Flange Blind - 8" RF, CL300, ASTM A105
ea
4
Yes
Available
10.
4
Yes
Available
11.
Flange Blind - 8" RF, CL300, ASTM A105 with 1/2" ea
Centre Tap
Spectacle blind, FF - 8" FF, CL300, ASTM A105
ea
3
Yes
Available
12.
Spectacle blind, FF - 14" FF, CL150, ASTM A105
ea
3
Yes
Available
13.
Flange Blind - 1-1/2" RF, CL300, ASTM A105, with ea
Centre Tap
Flange Blind - 1-1/2" RF, CL300, ASTM A105,
ea
4
Yes
Available
3
Yes
Available
6
Yes
Available
16.
Ball Valve - 8" Flanged RF, AISI 316 Trim,Soft Seat, ea
RPTFE seal, Trunnion mounted, Full Bore, Gear
Operated, Manual, class 300, ASME B16.34, Body:
ASTM 216 WCB.
Plug - 1/2" Hexagonal Solid 3000# MNPT
ea
15
Yes
Available
17.
Plug - 3/4" Hexagonal Solid 3000# MNPT
ea
2
Yes
Available
18.
Stud Bolts and Nuts - 3/4" x 89mm Stud Bolts with 2 ea
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 1-1/2'' 300# Flange) ASTM
A193 GR.B7 / ASTM A194 GR. 2H
Stud Bolts and Nuts - 7/8" x 150mm Stud Bolts with 2 ea
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 1-1/2'' 300# Flange) ASTM
A193 GR.B7 / ASTM A194 GR. 2H
Stud Bolts and Nuts - 3/4" X 130 mm Stud Bolts with 2 ea
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 6'' 300# Flange
12
Yes
Available
120
Yes
Available
30
Yes
Available
5.
6.
14.
15.
19.
20.
Page 6 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
21.
ea
24
Yes
Available
ea
42
Yes
Available
ea
42
Yes
Available
ea
36
Yes
Available
ea
60
Yes
Available
ea
3
Yes
Available
27.
Stud Bolts and Nuts - 1-1/8" X 180 mm Stud Bolts with
2 Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 12'' 300# Flange)
Stud Bolts and Nuts - 7/8" X 180 mm Stud Bolts with 2
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised
Stud Bolts and Nuts - 7/8" X 140 mm Stud Bolts with 2
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 8'' 150# Flange & Spec blind)
Stud Bolts and Nuts - 1" X 170 mm Stud Bolts with 2
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 14'' 150# Flange & Spec blind)
Stud Bolts and Nuts - 1" x 140mm Stud Bolts with 2
Nuts, Threaded full length, dim to ANSI B18.2.1 & 2 Hot Dip Galvanised (For 1-1/2'' 300# Flange) ASTM
A193 GR.B7 / ASTM A194 GR. 2H
U-Bolt - 8" CS Hot Dipped Galvanised to ASTM A153
C/W 4 Nuts
Neoprene Pad - 6mm Thick, Black Colour
Sq. M
1
Yes
Available
28.
Tungsten Electrode - 2.4mm (coated with red)
Packet
1
Yes
Available
29.
Tungsten Electrode - 3mm
Packets
1/2
Yes
Available
30.
Grinding Disc - 9" Grinding Disc
Pieces
10
Yes
Available
31.
Grinding Disc - 4" Grinding Disc
Pieces
10
Yes
Available
32.
Cutting Disc - 9" Cutting Disc (Batonflex)
Pieces
20
Yes
Available
33.
Cutting Disc - 4.5" Cutting Disc (Batonflex)
Pieces
60
Yes
Available
34.
GTAW Filler Metal - 2.4mm F6, ER 70S-2
Packet
1
Yes
Available
35.
GTAW Filler Metal - 3.2mm F6, ER 70S-2
Packet
1
Yes
Available
36.
Electrode - 2.5mm, ESAB Electrode (E7018)
Packets
2
Yes
Available
37.
Electrode - 3.2mm, ESAB Electrode (E7018)
Packets
3
Yes
Available
38.
Argon Gas - 7.5CuM
Bottles
3
Yes
Available
39.
Nitrogen gas - 7.2Cum
Bottles
24
Yes
Available
40.
WD40
Pieces
14
Yes
Available
41.
Touch-up Paint - International-Interzinc 52 (Primer)
Litres
10
Yes
Available
22.
23.
24.
25.
26.
Page 7 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
42.
10
Yes
Available
10
Yes
Available
44.
Touch-up Paint - International- Interseal 670 Litres
(Intermediate)
Touch-up Paint - International-Interthane 990 (RAL Litres
9006/7035) - Final
Thinner - International-Interthane (A220)
Litres
10
Yes
Available
45.
Thinner – Abro
Litres
5
Yes
Available
46.
Bottled Water
Packets
50
No
47.
Hack Saw Blade
Pcs
10
Yes
To be
procured
Available
48.
Welding Cable Connector
Pairs
2
Yes
Available
49.
Caution Tape
Rolls
2.5
Yes
Available
50.
Sand Paper
Rolls
2
Yes
Available
51.
Painting Brush
Pcs
2
Yes
Available
52.
Welders Glass - Plain
Pieces
40
Yes
Available
53.
Welders Glass - Dark - Shade 11
Pieces
20
Yes
Available
54.
Pieces
6
Yes
Available
Pieces
4
Yes
Available
Pieces
5
Yes
Available
Packets
3
58.
Hand Gloves - Argon Hand Gloves (American safety
Long sleeved) proguard
Hand Gloves - Tilman 750L Welding Hand Gloves
(SMAW)
Hand Gloves - Big Jake Mephis Fitting Hand Gloves (Soft
Leather)
Hand Gloves - Rubber Latex Industrial Hand Gloves
(Long)
Hand Gloves - Kong Impact
Pieces
7
Yes
Available
59.
Eye Goggles - 3M Safety Goggles Dark Anti-fog Lens
Pieces
15
Yes
Available
60.
Eye Goggles - 3M Safety Goggles Clear Anti-fog Lens
Pieces
10
Yes
Available
61.
Faceshield - Fitters' Face Shield
Pieces
5
Yes
Available
62.
Ear Plugs - 3M Reusable Ear Plugs
Packet
1
Yes
Available
63.
Respirator - 3M Double Cartridge Reuseable Respirator Pieces
7
Yes
Available
64.
Coverall - Coverall
Pieces
10
65.
Hard hat
Pieces
10
66.
Rain coat - Long
Pieces
10
Yes
Available
43.
55.
56.
57.
Page 8 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
67.
Rain Boot
Pieces
10
68.
Nose Mask - 3M Disposable Nose Mask
Packet
1
69.
Welding Apron
Nos
2
70.
Welding Sleeve
Pairs
2
71.
Ceramic cup (Size 6, 7, & 8 - 10 Pcs Each)
Pieces
72.
Diesel (AGO)
Yes
Available
30
Yes
Available
Litres
200
Yes
Available
UoM
Qty
Available
Functional
4.3 Tools & Equipment
Table 4-3: List of Tools and Equipment
Description
Model / Serial No. / ID
Miller
Bobcat
250; No
MA020239M
EATL/EQ/WM/010;
No
1001011898
TU3-1441-69; ISE 0112
No
1
Yes
Yes
1
Yes
Yes
1
Yes
Yes
TU3-1204-99; ISE 0110
No
1
Yes
Yes
TU7-1438-24; ISE-0114
No
1
Yes
Yes
A1503Y9
No
1
Yes
Yes
A1503Y10
No
1
Yes
Yes
C1513YZ
No
1
Yes
Yes
9.
Diesel Welding Machine,
Miller
Diesel Welding Machine,
Lincoln SAE 400
Square Drive Hydraulic
Torque Wrench
Square Drive Hydraulic
Torque Wrench
Square Drive Hydraulic
Torque Wrench
Pneumatic Torque Pump,
TorcUp
Pneumatic Torque Pump,
TorcUp
Pneumatic Torque Pump,
TorcUp
Set of Screw Drivers
N/A
Set
1
Yes
Yes
10.
Hack Saw
N/A
Pc
1
Yes
Yes
11.
Pc
1
Yes
Yes
12.
Concrete
Drillinng DM021260003
Machine, Raider
Fire Extinguisher
EATL/17411424F43-E
Pc
1
Yes
Yes
13.
Fire Extinguisher
EATL/177444E3C22-E
Pc
1
Yes
Yes
14.
Gas Detector
00222734
Pc
1
Yes
Yes
S/N
1.
2.
3.
4.
5.
6.
7.
8.
Page 9 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
15.
Cordex Safe Camera
Pc
1
Yes
Yes
Pincers
B214E200;
EATL/188D930C27F-E
N/A
16.
Nos
2
Yes
Yes
17.
Chain Block, 5T
N/A
Pc
1
Yes
Yes
18.
Grinding Machine, 4"
126008310; 692012479-1
Pc
1
Yes
Yes
19.
Grinding Machine, 4"
Pc
1
Yes
Yes
20.
Grinding Machine, 9"
Pc
1
Yes
Yes
21.
Grinding Machine, 9"
Pc
1
Yes
Yes
22.
Die Grinder, Dongcheng
0601375043;
EATL/EATL/GM/009/24
224013870;
EATL/EATL/GM/008/24
126008309;
EATL/EATL/GM/010/24
S1J-FF02-25
Sets
2
Yes
Yes
23.
/ N/A
Sets
2
Yes
Yes
24.
Industrial Extension
Cable
Wedge Anchor Bolts
N/A
Pcs
12
Yes
Yes
25.
Brass Hammer, 2Kg
N/A
Pcs
2
Yes
Yes
26.
Brass Hammer, 4Kg
N/A
Pcs
2
Yes
Yes
27.
Square
N/A
Pcs
2
Yes
Yes
28.
Pipe Wrench
N/A
Pcs
3
Yes
Yes
29.
Adjustable Spanner, 12"
N/A
Pcs
1
Yes
Yes
30.
Adjustable Spanner
N/A
Pcs
1
Yes
Yes
31.
N/A
Set
1
Yes
Yes
HES01
Set
1
Yes
Yes
EATL/181C9AD7B0E-E
Set
1
Yes
Yes
34.
Pneumatic
Flange
Spreader , Enerpac
Hydraulic Hand Pump,
Enerpac
Hydraulic Hand Pump,
Enerpac
Twin Line Hose
N/A
Set
4
Yes
Yes
35.
Torque Wrench - Manual
EATL/1838933S 97E
No
1
Yes
Yes
36.
Torque Wrench - Manual
EATL/18389348248-E
No
1
Yes
Yes
37.
Combination Spanner - N/A
1/2"
Pc
1
Yes
Yes
32.
33.
Page 10 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
38.
N/A
Pc
1
Yes
Yes
N/A
Pc
1
Yes
Yes
N/A
Pc
5
Yes
Yes
N/A
Pc
1
Yes
Yes
N/A
Pc
2
Yes
Yes
Pc
1
Yes
Yes
Pc
1
Yes
Yes
45.
Spanner - 1-5/16" (Pointed N/A
end)
Combination
Spanner N/A
36mm
Backup Spanner - 36mm
N/A
Pc
2
Yes
Yes
46.
Flogging Spanner - 36mm
N/A
Pc
1
Yes
Yes
47.
Flogging Spanner - 41mm
N/A
Pc
2
Yes
Yes
48.
Backup Spanner - 41mm
N/A
Pc
2
Yes
Yes
49.
Flogging Spanner - 32mm
N/A
Pc
1
Yes
Yes
50.
Pc
1
Yes
Yes
51.
Combination Spanner - N/A
55mm (2-3/16")
Flogging Spanner - 55mm N/A
Pc
1
Yes
Yes
52.
Backup Spanner - 55mm
N/A
Pc
1
Yes
Yes
53.
Ring Spanner - 32mm
N/A
Pc
1
Yes
Yes
54.
Ring Spanner - 50mm
N/A
Pc
1
Yes
Yes
55.
Flogging Spanner - 50mm
N/A
Pc
1
Yes
Yes
56.
Backup Spanner - 50mm
N/A
Pc
1
Yes
Yes
57.
Impact Socket - 60mm
N/A
Pc
1
Yes
Yes
58.
Impact Socket - 55mm
N/A
Pc
1
Yes
Yes
59.
Impact Socket - 50mm
N/A
Pc
1
Yes
Yes
60.
Impact Socket - 46mm
N/A
Pc
3
Yes
Yes
61.
Impact Socket - 41mm
N/A
Pc
3
Yes
Yes
62.
Impact Socket - 38mm
N/A
Pc
1
Yes
Yes
39.
40.
41.
42.
43.
44.
Combination Spanner 3/4"
Combination Spanner 30mm
Combination Spanner 32mm
Combination Spanner 46mm (1-13/16")
Flogging Spanner - 46mm
Page 11 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
63.
Impact Socket - 36mm
N/A
Pc
2
Yes
Yes
64.
Impact Socket - 32mm
N/A
Pc
2
Yes
Yes
65.
Magnetic Base Spirit Level
N/A
Pcs
2
Yes
Yes
66.
Fire Blanket
N/A
Pcs
20
Yes
Yes
67.
Argon Welding Set
N/A
Sets
3
Yes
Yes
68.
Gas Cylinder Trolley
N/A
Sets
2
Yes
Yes
69.
Welding Cables
N/A
Rolls
5
Yes
Yes
70.
Air Hose
N/A
Sets
3
Yes
Yes
71.
No
1
Yes
Yes
72.
Air Tank, Texas Pneumatic T78047
Tools Inc
Earth Rod
N/A
Pcs
2
Yes
Yes
73.
Hand Wire Brush
N/A
Pcs
2
Yes
Yes
74.
Pipe Wrap around
N/A
Rolls
2
Yes
Yes
75.
Safety Signages
N/A
Nos
3
Yes
Yes
76.
Container - 10-Ft
EATL/EQ/CCU/004
No
1
Yes
Yes
77.
Scaffold Pipe - 3m Length
N/A
Pcs
10
Yes
Yes
78.
Scaffold Pipe - 2m Length
N/A
Pcs
4
Yes
Yes
79.
Scaffold Base Plate
N/A
Pcs
4
Yes
Yes
80.
Scaffold Clip - double
N/A
Pcs
8
Yes
Yes
81.
Scaffold Clip - Swivel
N/A
Pcs
12
Yes
Yes
82.
MPI/UT Kit
N/A
Set
1
Yes
Yes
83.
Sets
2
Yes
Yes
84.
Complete
Mechanical N/A
Toolbox with set of
spanners
Electrode Quiver
0212209001
Nos
1
Yes
Yes
85.
Electrode Quiver
0212209002
Nos
1
Yes
Yes
86.
Air Compressor, Airman
EATL/EQ/CP/001
No
1
Yes
Yes
87.
Self-loader and
Accessories
Cylinder Rack
Lot
1
Yes
Yes
Nos
1
Yes
Yes
88.
Lifting AUQ-191XA
EATL/EQ/CR/001
Page 12 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
89.
Cylinder Rack
EATL/EQ/CR/003
Nos
1
Yes
Yes
90.
Cylinder Rack
SLSL/EQ/CR/009
Nos
1
Yes
Yes
91.
Cylinder Rack
SLSL/EQ/CR/010
Nos
1
Yes
Yes
92.
Rachet (for Scaffolding)
N/A
No
1
Yes
Yes
93.
Big Umbrella
N/A
Set
1
Yes
Yes
94.
Stainless Steel Manifold
EATL/EATL/AM/001/24
Set
1
Yes
Yes
95.
Instrument Toolbox
N/A
No
1
Yes
Yes
96.
High
Pressure
(11,000 Psi)
Pressure Guage
Hose N/A
Roll
1
Yes
Yes
Set
1
Yes
Yes
Set
1
Yes
Yes
97.
98.
Instrument
Accessories
Fittings
1202610-001
& N/A
99.
4.4 Logistics & Other Services
Table 4-4: Summary of Logistics and Other Services Requirements
S/N
1.
2.
3.
4.
5.
6.
Description
Vehicle 1 – Self-Loader
(for transportation of
materials, tools &
Equipment)
Vehicle 2 – Bus (for
transportation of
personnel)
Vehicle 3 – Hilux (for
transportation of
personnel)
Feeding of project
personnel
Accommodation for
project personnel
Petrol (PMS) – (for
EATL Bus)
Duration
(Days/Nights)
UoM
Qty
Rate
(NGN)
Amount
(NGN)
Remark
5
No
1
N/A
N/A
Available
5
No
1
N/A
N/A
Available
5
No
1
N/A
N/A
Available
7
Ea
16
5,000
560,000
7
Ea
16
15,000
1,680,000
N/A
Litres
300
800
240,000
To be
provided
To be
provided
To be
provided
Page 13 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
7.
N/A
Litres
300
1,800
540,000
8.
Diesel (AGO) - (for
EATL Vehicles - Hilux)
Bottled Water
N/A
Packets
50
2,200
110,000
9.
Exigency
1
L/S
1
300,000
300,000
TOTAL
To be
provided
To be
provided
To be
provided
3,430,000
(Three Million, Four Hundred and Thirty Thousand Naira)
5
POSSIBLE CHALLENGES AND PROPOSED MITIGATIVE ACTIONS
S/N
Possible Challenges
Proposed Mitigative Actions
1.
Equipment Failure
•
•
2.
Adverse Weather Condition
•
•
3.
Community Interference
•
Ensure that all faulty project equipments are
fixed prior to mobilisation
Only competent personnel should operate
equipment and machinery
Personnel should be provided with
appropriate PPE (Rain Coats)
Proper JHA should be carried out for activities
that may be affected by adverse weather
conditions
Ensure proper communication and alignment
with Client Community Relations personnel
before mobilisation
Page 14 of 15
DOCUMENT TITLE:
SITE INSTALLATION PLAN
DOCUMENT NO:
EATL/SAVE/SPLN/001/24
PROJECT:
REVISION NO.: 01
INSTALLATION OF UNICEM MASTER
FLOWMETER PROJECT
CONTRACT NO:N/A
Prepared by:
Reviewed by:
Endorsed by:
Approved by:
Aaron Ben-Elijah
Graduate Trainee
David Oku
Project QAQC
Friday Oyovorie
Construction Supervisor
Emmanuel Okon (FIOGR)
MD/CEO
Page 15 of 15