Uploaded by JOHN TANDAH TEAH JR

BOOKER WASHINGTON INSTITUTE

advertisement
BOOKER WASHINGTON INSTITUTE
(BWI) P.O. BOX 273
ELECTRICAL DEPARTMENT, KAKATA, MARGIBI COUNTY,
REPUBLIC OF LIBERIA
AIR CONDITION AND REFRIGERATION ASSIGNMENT
NAME: JOHN TANDAH TEAH JR ID#. : 8574 SCORE: ___________________ DATE: _____________________________
ASSIGNMENT # 1
PART1
Direction: These numbers of Air-Conditions; 9,000BTU, 12,000BTU, 18,000BTU and 24,000BTU, Select from among these. Connect
and install 2ACs in working condition.
Use 2 terminals running capacitor (RC) and one fan capacitor (FC) for one.
For the other, use 3 terminals running capacitor (RC). Use one 2 circuit panel box for each AC.
Show the sizes of Breakers, Conductor Number, Empty Amperage, Full Load Amperage, and AC Receptacle Fuse Amp Number.
Color Code Your Work, Use Scales.
PART 2:

List 10 needed Materials for each job among thousands

List 10 tools for these jobs
ASSIGNMENT # 2
PART 1:
1. Connect the compressor with two (2) terminals running capacitor only, show power source N&P1.
2. Connect the fan with three (3) terminals running capacitor only. Show power source N&P1.
3. Connect the AC fan with fan capacitor only. Use two (2) circuit panel boxes in working condition. Explain the
diagram
4. Name the eight methods according to our studies, when a compressor is not good.
5. Name five safety rules as a technician.
PART 2:
1. We agreed that if the compressor loses suction it will not pump well yes, and it will not suck well yes. But tell me what
will happen?
2. Explain where and when do we apply the good uses of these capacitors as a technician on AC.
A. FAN CAPACITOR
B.THREE TERMINALS RUNNING CAPACITOR
C.
TWO TERMINALS RUNNING CAPACITOR
3.
4.
R/A study base on ________________________________________ and _______________________________________________
Gassing an ICE box of freezer, freezer starts cooling but ICE melts later, what happen?
A) _________________________________ B) _____________________________________
C) _________________________________ D) _____________________________________
E) ________________________________________________________________________
F) _______________________________________________
ASSIGNMENT # 3
PART 1
DIRECTIONS: Chose the correct answer to match the question, on the left with the answer provided in the spaces from the right. Do
not erase.
1. American and Europeans wire # are written below; give the correct amperage in the spaces provided in the middle.
NO. WIRE NUMBER
SPACES FOR ANSWERING
ANSWERS
1
14
110 -------------- 150A
2
12
90 -------------------100A
3
10
70 --------------- 75A
4
8
50 ----------------- 55A
5
6
40 ------------------45A
6
4
30 ----------------- 35A
7
1
20 ----------------25A
8
1.5mm
15 ----------------- 20A
9
2.5mm
30 ----------------- 35A
10
4mm
40 ------------------45
11
16mm
50 ------------------55A
12
25mm
70 -----------------74A
13
35mm
110 ------------- 120A
14
50mm
110 -------------150A
25
75mm
NONE OF THESE
PART 2
DIRECTION: Fill in the Blank spaces with the correct questions. Used the voltage regulator that suit these freezers
16. From 1/12 to 1/10 we should use _______________________________watts
17. From 1/8 to 1/6 we should use _________________________________watts
18. From 1/5 to 1/4 we should use _________________________________watts
19. From 1/4 to 1/3 we should use _________________________________ watts
PART 3
DIRECTIION: Use the correct R/C on these AC
From: 9,000 BTU to 4,000 BTU A/C
NO.
20
9,000 BTU
55uf --------- 60uf
21
12,000 BTU
23uf ---------30uf
22
18,000 BTU
35uf ---------45uf
23
24,000 BTU
50uf ---------55uf
24
35,000 BTU
45uf ---------50uf
25
48,000 BTU
30uf ---------40uf
NONE OF THESE
Place the answer here
Download