BOOKER WASHINGTON INSTITUTE (BWI) P.O. BOX 273 ELECTRICAL DEPARTMENT, KAKATA, MARGIBI COUNTY, REPUBLIC OF LIBERIA AIR CONDITION AND REFRIGERATION ASSIGNMENT NAME: JOHN TANDAH TEAH JR ID#. : 8574 SCORE: ___________________ DATE: _____________________________ ASSIGNMENT # 1 PART1 Direction: These numbers of Air-Conditions; 9,000BTU, 12,000BTU, 18,000BTU and 24,000BTU, Select from among these. Connect and install 2ACs in working condition. Use 2 terminals running capacitor (RC) and one fan capacitor (FC) for one. For the other, use 3 terminals running capacitor (RC). Use one 2 circuit panel box for each AC. Show the sizes of Breakers, Conductor Number, Empty Amperage, Full Load Amperage, and AC Receptacle Fuse Amp Number. Color Code Your Work, Use Scales. PART 2: List 10 needed Materials for each job among thousands List 10 tools for these jobs ASSIGNMENT # 2 PART 1: 1. Connect the compressor with two (2) terminals running capacitor only, show power source N&P1. 2. Connect the fan with three (3) terminals running capacitor only. Show power source N&P1. 3. Connect the AC fan with fan capacitor only. Use two (2) circuit panel boxes in working condition. Explain the diagram 4. Name the eight methods according to our studies, when a compressor is not good. 5. Name five safety rules as a technician. PART 2: 1. We agreed that if the compressor loses suction it will not pump well yes, and it will not suck well yes. But tell me what will happen? 2. Explain where and when do we apply the good uses of these capacitors as a technician on AC. A. FAN CAPACITOR B.THREE TERMINALS RUNNING CAPACITOR C. TWO TERMINALS RUNNING CAPACITOR 3. 4. R/A study base on ________________________________________ and _______________________________________________ Gassing an ICE box of freezer, freezer starts cooling but ICE melts later, what happen? A) _________________________________ B) _____________________________________ C) _________________________________ D) _____________________________________ E) ________________________________________________________________________ F) _______________________________________________ ASSIGNMENT # 3 PART 1 DIRECTIONS: Chose the correct answer to match the question, on the left with the answer provided in the spaces from the right. Do not erase. 1. American and Europeans wire # are written below; give the correct amperage in the spaces provided in the middle. NO. WIRE NUMBER SPACES FOR ANSWERING ANSWERS 1 14 110 -------------- 150A 2 12 90 -------------------100A 3 10 70 --------------- 75A 4 8 50 ----------------- 55A 5 6 40 ------------------45A 6 4 30 ----------------- 35A 7 1 20 ----------------25A 8 1.5mm 15 ----------------- 20A 9 2.5mm 30 ----------------- 35A 10 4mm 40 ------------------45 11 16mm 50 ------------------55A 12 25mm 70 -----------------74A 13 35mm 110 ------------- 120A 14 50mm 110 -------------150A 25 75mm NONE OF THESE PART 2 DIRECTION: Fill in the Blank spaces with the correct questions. Used the voltage regulator that suit these freezers 16. From 1/12 to 1/10 we should use _______________________________watts 17. From 1/8 to 1/6 we should use _________________________________watts 18. From 1/5 to 1/4 we should use _________________________________watts 19. From 1/4 to 1/3 we should use _________________________________ watts PART 3 DIRECTIION: Use the correct R/C on these AC From: 9,000 BTU to 4,000 BTU A/C NO. 20 9,000 BTU 55uf --------- 60uf 21 12,000 BTU 23uf ---------30uf 22 18,000 BTU 35uf ---------45uf 23 24,000 BTU 50uf ---------55uf 24 35,000 BTU 45uf ---------50uf 25 48,000 BTU 30uf ---------40uf NONE OF THESE Place the answer here