INSTRUCTION OF TECHNICAL REPORT & REGISTER Doc. Code: BD-OPS-PRO-I1049/F1 Revision: 01 TECHNICAL REPORT Report No: (003-2024) Date: (16/04/2024) Discipline: (Mechanical) Regarding to: Lube Oil Pump HT-P-4101A has abnormal signal about vibration and noise. Date to fix : Report to: C/c to: Inspectors: 16/04/2024 Mechanical Supv D.OIM Nguyen Ngoc Giao – Mech Tech Doan Dinh Hach – Mech Tech Location: Reporter: Ref.: HT1 PQP cellar deck Doan Dinh Hach _______________________________________ No. of page(s) (Including this cover sheet):10 Description of a report 1. Equipment/system name: HT-P-4101A: Lube oil pump of HT-K-4100 2. Status of equipment/system before inspect: (attach evidence, P&ID, etc. if needed for clarity) Date 26/02/2024, while collect data for all rotating equipment on PQP that running hours over 40.000 hrs, EnI found Motor HT-PM-4101A has abnormal vibration signal. And then taking ultrasound data for the pump HT-P-4101A has a louder noise than the pump HTP4101B, it is necessary to inspect the condition of Lube oil Pump HT-P-4101A. Total running hours of HT-P-4101A: 44000 hrs Page 1 of 9 3. Steps of inspection: Step 1 Review running parameter of Lube Oil Pump HT-P-4101A (from 22/01/204 to 14/03/2024) Collection running data for HT-P-4101A: Date Suction pressure/Discharge pressure of HT-P-4101A 22/01/2024 Suction pressure: 3.2 bar (Pump HTP-4101A running when MR4100 running) Discharge pressure: 5.62 bar Date Power and Curent of Motor HT-PM-4101A 22/01/2024 Power: 1.8 KW (Max : 2.2 KW) (Pump HTP-4101A running when MR4100 running) Current: 3.3 A Page 2 of 9 Evaluate: Pump work in normal suction and discharge pressure. Total running hours of HT-P-4101A: 44000 hrs Step 2 26/02/2024 E&I carryout asset condition monitoring for HT-PM-4101A and prepare for replace motor follow WO P13452572 Mech collect running paramater for HT-P-4101A as below 26/02/2024 Suction pressure: 5.61 bar (P-4101A running by Force mode, due to MR4100 stopped) Discharge pressure: 8.15 bar 26/02/2024 Power: 1.82 KW (P-4101A running by Force mode, due to MR4100 stopped) Current: 3.37 A Page 3 of 9 26/02/2024 Ultrasound for Pump HT-P-4101A: No data Step 3 09/03/2024 carry out asset condition monitoring for HT-PM-4101A and take ultrasound for the pump by LongVH. Date Record ultralsound for HT-P-4101A and Analysis by By Long VH: 09/03/2024 For MR Lub. Oil pump A (HT-P-4101A): After taking vibration and ultrasound, evaluate the pump head for signs of damage, suspect the bearing on the DE side. (EnI not yet See detail as below: replace motor, P4101A running by Force mode, due to MR4100 stopped) Page 4 of 9 Evaluate: After taking vibration and ultrasound, evaluate the pump head for signs of damage, suspect the bearing on the DE side. Step 4 EnI replace new motor, WO P13452572. 12/03/2024 Step 5 Mech visual inspection pump: 12/03/2024 Disconnect motor and pump adapter 12/03/2024 Visual check coupling alignment Page 5 of 9 12/03/2024 Visual check DE bearing (outside position) Visual check bearing found the bearing locking device has loosen and the inner bearing has light scratches, may cause Bearing and rotor shaft start to down grade. Step 6 After EnI install the new motor, run test the pump in force mode and collect parameter data. 14/03/2024 Suction pressure: 5.44 bar (after EnI replace new motor, P4101A running by Force mode, due to MR4100 stopped) Discharge pressure: 8 bar Page 6 of 9 14/03/2024 Power: 1.88 KW (P-4101A running by Force mode, due to MR4100 stopped) Current: 4.09 A Ultrasound data of Pump HT-P-4101A 14/03/2024 HT-P4101A running by Force mode, due to MR4100 stopped) For MR Lub. Oil pump A (HT-P-4101A): after EnI replaced the motor, the pump run test and investigated with Mr. LongVH, evaluate the pump head for signs of damage, suspecting the DE side bearings. EnI team has replaced the spare motor, signs of ultrasound impact still appear on the pump. See detail as below: Picture 3: Time waveform Page 7 of 9 Picture 4:FFT spectrum shows peak at 31.6 Hz at Pump Casing 6/04/2024 16/04/2024 Install new pump , old pump transfer to Mech WS Old pump was dismantle in Mech WS, found defect on pump shaft at DE bearing position Evaluate: the old pump head of HT-P-4101A was defected shaft at DE bearing position 4. Status of equipment/system after inspected, finding: (attach evidence, P&ID, etc. if needed for clarity) Install new pump for using. Old pump was defected shaft at DE bearing position, will send onshore to repair for back up 5. Root cause: (if found) Direct root cause: Old pump was defected shaft at DE bearing position. 6. Recommendation: - Send old pump to onshore to repair by chopper 17/4/2024. - . - Disposal part: N/A Disposal located: N/A Useable spare part: Old pump will send to shore for refurbish and then replace for oil pump B (HT-P41010B). After that refurbish the old pump and spare for HT-P-4101A/B Useable located at: WH onshore. Page 8 of 9 Serial Number on Pump’s body: Name Nguyen Ngoc Giao Position Mechtech Doan Dinh Hach Mechtech Reviewed by Nguyen Hung Thanh Mech Sup Reviewed by Hoàng Văn Tuấn DOIM Approved by Đoàn Mai Lâm OIM Reported by Signature --------------------END OF REPORT-------------------- Page 9 of 9