OFFICES HOTELS PUBLIC SPACES PRODUCT LINE-UP DPSC Series Class 1.0kW 1.25kW 1.5kW 1.75kW 2.0kW 2.25kW 2.5kW 3.0kW 400mm DPSC0409 DPSC0412 DPSC0415 DPSC0418 DPSC0421 - - - 600mm - DPSC0609 - DPSC0612 - DPSC0615 DPSC0618 DPSC0621 Height DPDC Series Class Height 400mm 1 1.0kW 1.25kW 1.5kW 1.75kW 2.0kW DPDC-0409 DPDC-0412 DPDC-0415 DPDC-0418 DPDC-0421 PRODUCT FEATURES DISPLACEMENT VENTILATION Air distribution technology that introduces cool air into a low-level zone at low velocity & less air draught. OFFICE BUILDINGS ENERGY SAVING For green building systems, it provides opportunities for energy savings as it does not require fan. HOTELS QUIET OPERATION Improved room comfort without mechanical sound from fan motor, blower and bearing. EASY INSTALLATION PDV units are easily installed due to its compact size, slim, light weight, fewer diffusers and less ductwork. SHOPPING MALLS ZONE TEMPERATURE CONTROL PDV units temperatures can be zone controlled. PUBLIC BUILDINGS 2 DISPLACEMENT VENTILATION DIAGRAM AIRFLOW SIMULATION PDV airflow simulation example PDV 1.0m Return Air Grille Supply Air Duct 3.0m 3.75m 3.0m 16.0 18.0 20.0 22.0 24.0 Temperature (Fluid) °C PDV Return Air Grille Meeting Room SECTION VIEW 3 PLAN VIEW AT 1.0M HEIGHT FFL 26.0 28.0 DPSC SERIES SPECIFICATIONS 400 Coil Height Model DPSC-0409 DPSC-0412 DPSC-0415 DPSC-0418 DPSC-0421 Total Cooling Capacity[1] kW 0.87 1.19 1.52 1.73 2.06 Coil Dimension (with Drain Pan) Height mm 471 471 471 471 471 Width mm 1040 1340 1640 1940 2240 Depth mm 210 210 210 210 210 Coil No. / Row / Fin Per Inch 1 / 2 / 10 Weight kg 20.7 24.9 28.4 31.1 34.6 Water Flow Rate L/s 0.042 0.057 0.073 0.083 0.099 Fluid Pressure Drop kPa 0.32 0.56 0.86 1.14 1.55 Supply mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) Return mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) mm Ø 16.5 Pipe Connection [2] Condensate Drain Size 600 Coil Height Model DPSC-0609 DPSC-0612 DPSC-0615 DPSC-0618 DPSC-0621 Total Cooling Capacity[1] kW 1.35 1.73 2.22 2.60 3.09 Coil Dimension (with Drain Pan) Height mm 624 624 624 624 624 Width mm 1040 1340 1640 1940 2240 Depth mm 210 210 210 210 210 Coil No. / Row / Fin Per Inch 1 / 2 / 10 Weight kg 26.5 32.2 37.0 40.5 45.1 Water Flow Rate L/s 0.065 0.083 0.106 0.124 0.148 Fluid Pressure Drop kPa 0.42 0.67 1.05 1.43 1.97 Supply mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) Return mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) mm Ø 16.5 Pipe Connection [2] Condensate Drain Size Notes: [1] Nominal conditions: a) Chilled Water Supply: 7.0°C, Chilled Water Return: 12.0°C. b) Room temperature: 24.0°CDB / 60%RH. c) Effective Shaft Duct Height at 2.5m. [2] Piping connection to be specified by customer, either “left” or “right” viewing from return air side. 4 DPSC SERIES Dimensions Fin Length (mm) Fin Height (mm) H (mm) W (mm) D (mm) DPSC-0409 900 381 434 1040 150 DPSC-0412 1200 381 434 1340 150 DPSC-0415 1500 381 434 1640 150 DPSC-0418 1800 381 434 1940 150 DPSC-0421 2100 381 434 2240 150 DPSC-0609 900 571.5 624 1040 150 DPSC-0612 1200 571.5 624 1340 150 DPSC-0615 1500 571.5 624 1640 150 DPSC-0618 1800 571.5 624 1940 150 DPSC-0621 2100 571.5 624 2240 150 DPSC Series DPSC Series (600 coil height) (400 coil height) PDV Model 5 DPSC SERIES Recommended field ducting installation example SLAB SOFFIT 434mm (VARY ACCORDING PDV MODEL) 434mm (VARY ACCORDING PDV MODEL) 20 1200mm (VARY ACCORDING PDV MODEL) REFER TO DETAIL 'A' DRAIN PAN FALSE CEILING Rated Installation Height = 2500mm 100mm AIR GAP FOR DPSC 400 SERIES 150MM AIR GAP FOR DPSC 600 SERIES 20mm PRE-INSULATED DUCT 12mm GYPSUM BOARD (SURFACE FINISHING TO ARCHITECT'S SPECIFICATIONS AND APPROVAL) 200 20 200 LINEAR BAR GRILLE WITH 70% FREE AREA 20 FFL 1200mm (VARY ACCORDING PDV MODEL) 152 FRONT VIEW SECTION VIEW SLAB SOFFIT 434mm (VARY ACCORDING PDV MODEL) CHWR CHWS COIL SHALL BE MOUNTED IN A GALVANISED STEEL FRAME FIXED TO SLAB SOFFIT FOR SUPPORT AND FLUSHED TO DUCTS ON ALL SIDES. DRAIN PAN Ø15mm INSULATED PVC DRAIN PIPE CONNECTED TO THE NEAREST DRAIN POINT. 100 DETAIL 'A' 6 DPDC SERIES Specifications 400 Coil Height Model DPDC-0409 DPDC-0412 DPDC-0415 DPDC-0418 DPDC-0421 Total Cooling Capacity[1] kW 0.94 1.24 1.56 1.86 2.18 Coil Dimension (with Drain Pan) Height mm 425.6 425.6 425.6 425.6 425.6 Width mm 1030 1330 1630 1930 2230 Depth mm 346 346 346 346 346 Coil No. / Row / Fin Per Inch 2 / 3 / 10 Weight kg 43.1 52.1 59.6 65.5 73.1 Water Flow Rate L/s 0.045 0.060 0.075 0.089 0.104 Fluid Pressure Drop kPa 0.32 0.55 0.84 1.18 1.59 Supply Pipe Connection [2] Return mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) mm Ø 12.7 (Brass Connection Ø 21.7 OD c/w BSPT Male Threaded) Condensate Drain Size mm Ø 16.5 Notes: [1] Nominal conditions: a) Chilled Water Supply: 7.0°C, Chilled Water Return: 12.0°C. b) Room temperature: 24.0°CDB / 60%RH. c) Effective Shaft Duct Height at 0.25m. [2] Piping connection to be specified by customer, either “left” or “right” viewing from return air side. Dimensions Fin Length (mm) Fin Height (mm) H (mm) W (mm) D (mm) DPDC-0409 900 355.6 425.6 1030 346 DPDC-0412 1200 355.6 425.6 1330 346 DPDC-0415 1500 355.6 425.6 1630 346 DPDC-0418 1800 355.6 425.6 1930 346 DPDC-0421 2100 355.6 425.6 2230 346 DPDC Series (400 coil height) PDV Model 7 DPDC SERIES Recommended field ducting installation example TOP VIEW FRONT VIEW SECTION VIEW 8 COOLING CAPACITY PERFORMANCE DPSC Series DPDC Series Chilled Water Temperature Correction Factor: T Water Inlet = 8°C, fQ= 0.90 9 OPTIONS Local Control System Item Remote Controller Item Modulating Control Valve Item Pressure Independent Control Valve (PICV): Model Description Siemens RDD100 Temperature Setting: 5 ~ 35°C Model Description R2015-4-S1 + TR24-SR Flowrate: 0.111 L/s R2020-6P3-S1 + TR24-SR Flowrate: 1.75 L/s R2025-10-S2 + LR24A-SR Flowrate: 2.778 L/s R2032-20-S2 + LR24A-SR Flowrate: 5.556 L/s Model Description TA-Modulator-15 + TA-Slider 160 Flowrate: 0.026 ~ 0.133 L/s TA-Modulator-20 + TA-Slider 160 Flowrate: 0.056 ~ 0.271 L/s TA-Modulator-25 + TA-Slider 160 Flowrate: 0.094 ~ 0.486 L/s TA-Modulator-32 + TA-Slider 160 Flowrate: 0.200 ~ 1.000 L/s 10 • Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. • Use only those part and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. • Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Daikin Airconditioning (Singapore) Pte. Ltd. 10 Ang Mo Kio Industrial Park 2 Singapore 569501 Phone: +65 6583 8888 Email: sales@daikin.com.sg DAIKIN SINGAPORE DSP-PDV-19001 www.daikin.com.sg Specifications, designs and other content appearing in this brochure are current as of February 2020 but subject to change without notice. c All rights reserved.