Y1 6-Port Antenna Frequency Range 1710–2690 X Dual Polarization 65° HPBW Adjust. Electr. DT 2°–14° Y2 Y3 1710–2690 1710–2690 X X 65° 65° 2°–14° 2°–14° set by 6-Port Antenna 1710–2690/1710–2690/1710–2690 65°/65°/65° 18/18/18dBi 2°–14°/2°–14°/2°–14°T Type No. 80010727 Left system Y1, connector 1– 2 Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression MHz dBi dBi 1710 – 1880 17.6 17.5 ± 0.5 1850 – 1990 18.2 18.2 ± 0.3 1710 – 2690 1920 – 2180 18.3 18.2 ± 0.2 2300 – 2400 18.5 18.4 ± 0.4 2490 – 2690 18.5 18.2 ± 0.5 ° 67 ± 4.3 64 ± 2.3 62 ± 2.3 59 ± 2.9 57 ± 3.3 dB > 25 > 24 > 24 > 24 > 24 dB > 25 > 25 > 25 > 27 > 20 dB > 12.0 > 10.0 > 9.0 > 8.5 > 10.0 dB < 1.0 < 1.0 < 1.0 < 1.5 < 2.0 ° 7.0 ± 0.5 6.4 ± 0.3 6.1 ± 0.5 5.3 ± 0.2 4.8 ± 0.3 ° < 0.4 < 0.4 < 0.4 < 0.4 < 0.3 dB > 17 > 20 > 20 > 18 > 19 ° 2.0 – 14.0 936.4615/d ngmn 04.18.05.06 Subject to alteration. Cross Polar Isolation dB > 30 Port to Port Isolation dB > 30 (Y1 // Y2 // Y3) Max. Effective Power W 250 (at 50 °C ambient temperature) per Port Max. Effective Power W 500 (at 50 °C ambient temperature) Port 1–2 Values based on NGMN-P-BASTA (version 9.6) requirements. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com 80010727 Page 1 of 4 6-Port Antenna Center system MHz dBi dBi 1710 – 1880 17.3 17.2 ± 0.4 1850 – 1990 17.8 17.8 ± 0.4 1710 – 2690 1920 – 2180 18.0 17.9 ± 0.3 2300 – 2400 18.1 17.8 ± 0.5 2490 – 2690 18.0 17.9 ± 0.5 ° 68 ± 7.0 62 ± 4.9 61 ± 3.4 63 ± 2.5 59 ± 3.9 dB > 24 > 24 > 24 > 25 > 24 dB > 26 > 28 > 30 > 29 > 24 dB > 10.5 > 9.5 > 10.5 > 9.0 > 8.5 dB < 1.5 < 1.0 < 1.5 < 2.0 < 2.5 ° 6.9 ± 0.4 6.4 ± 0.3 6.1 ± 0.4 5.3 ± 0.2 5.0 ± 0.3 ° < 0.4 < 0.3 < 0.3 < 0.4 < 0.2 dB > 20 > 24 > 22 > 22 > 18 ° 2.0 – 14.0 Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 3–4 Values based on NGMN-P-BASTA (version 9.6) requirements. > 28 > 30 (Y1 // Y2 // Y3) 250 (at 50 °C ambient temperature) 500 (at 50 °C ambient temperature) Right system Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Y3, connector 5 – 6 MHz dBi dBi 1710 – 1880 17.6 17.6 ± 0.5 1850 – 1990 18.2 18.1 ± 0.3 1710 – 2690 1920 – 2180 18.3 18.2 ± 0.3 2300 – 2400 18.5 18.4 ± 0.5 2490 – 2690 18.6 18.3 ± 0.4 ° 68 ± 3.9 65 ± 2.3 64 ± 2.8 58 ± 4.2 57 ± 2.4 dB > 24 > 25 > 24 > 23 > 22 dB > 24 > 24 > 25 > 25 > 21 dB > 13.0 > 10.5 > 9.5 > 8.0 > 11.5 dB < 1.0 < 1.0 < 1.0 < 2.0 < 2.0 ° 6.9 ± 0.5 6.4 ± 0.3 6.1 ± 0.4 5.3 ± 0.2 4.8 ± 0.2 ° 2.0 – 14.0 ° < 0.3 < 0.4 < 0.4 < 0.4 < 0.5 dB > 19 > 23 > 23 > 21 > 21 Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 5–6 Values based on NGMN-P-BASTA (version 9.6) requirements. Page 2 of 4 80010727 > 30 > 30 (Y1 // Y2 // Y3) 250 (at 50 °C ambient temperature) 500 (at 50 °C ambient temperature) All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com 936.4615/d ngmn 04.18.05.06 Subject to alteration. Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Y2, connector 3 – 4 6-Port Antenna Mechanical specifications Electrical specifications, all systems Impedance Ω 50 VSWR < 1.5 Return Loss dB > 14 Interband Isolation dB > 30 Passive Intermodulation dBc < –150 (2 x 43 dBm carrier) Polarization ° +45, –45 800 (at 50 °C ambient Max. Effective Power W temperature) for the Antenna Values based on NGMN-P-BASTA (version 9.6) requirements. Input Connector Position Adjustment Mechanism Wind load (at Rated Wind Speed: 150 km/h) Max. Wind Velocity N | lbf km/h mph Height / Width / Depth mm inches Category of Mounting Hardware Weight kg lb Packing Size mm inches Scope of Supply Accessories (order separately if required) 6 x 7-16 female bottom FlexRET, continuously adjustable Frontal 860 | 193 Lateral 200 | 45 Rearside 860 | 193 200 124 1475 / 378 / 103 58.1 / 14.9 / 4.1 M (Medium) 18.0 / 20.2 (clamps incl.) 39.7 / 44.5 (clamps incl.) 2000 / 549 / 120 78.7 / 21.6 / 4.7 Panel, FlexRET and 2 units of clamps for 42 – 115 mm | 1.7– 4.5 inches diameter 2) Type No. Description Remarks mm | inches 731651 85010002 85010003 737978 86010154 86010155 1 clamp 1 clamp 1 clamp 1 downtilt kit Site Sharing Adapter Site Sharing Adapter Mast diameter: 28 – 60 | 1.1 - 2.4 Mast diameter: 110 – 220 | 4.3 – 8.7 Mast diameter: 210 – 380 | 8.3 – 15.0 Downtilt angle: 0° – 15° 3-way (see figure below) 6-way (see figure below) 1) 1) 64 | 2.5 2) 9 | 0.4 Weight Units per approx. kg | lb antenna 0.8 | 1.8 2.7 | 6.0 4.8 | 10.6 2.3 | 5.1 0.65 | 1.4 1.35 | 3.0 2 2 2 1 1.1 | 2.4 2 738546 86010153 1 clamp FlexRET Mast diameter: 42 – 115 | 1.7 – 4.5 1475 | 58.1 1496 | 58.9 1607 | 63.3 Accessories (included in the scope of supply) For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Reflector screen: Aluminum. Fiberglass radome: The grey fiberglass radomes of these antennas are very stable and extraordinarily stiff. They are resistant to ultraviolet radiation and can also be painted to match their surroundings. All screws and nuts: Stainless steel. 936.4615/d ngmn 04.18.05.06 Subject to alteration. Material: Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. Configuration example with Site Sharing Adapter 86010154 FlexRET FlexRET Configuration example with Site Sharing Adapter 86010155 FlexRET FlexRET FlexRET FlexRET All dimensions in mm | inches Site Sharing Adapter 3-way Site Sharing Adapter 6-way AISG BTS-A AISG BTS-B BTS-C BTS1 BTS2 BTS3 BTS4 BTS5 BTS6 For more information please refer to the respective data sheets. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com 80010727 Page 3 of 4 6-Port Antenna Layout of interface: 103 | 4.1 Y1(L) / Y2(C) / Y3(R) 1710–2690 120 | 4.7 220 | 8.7 320 | 12.6 378 | 14.9 Bottom view All dimension in mm | inches Frequency range Array Connector 1710 – 2690 MHz 1710 – 2690 MHz 1710 – 2690 MHz Y1 Y2 Y3 1–2 3–4 5–6 Y1 Y2 Y3 Left Center Right Any previous data sheet issues have now become invalid. Page 4 of 4 80010727 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com 936.4615/d ngmn 04.18.05.06 Subject to alteration. Correlation Table Mounting Hardware Clamp Included in the Scope of Supply Suitable for mast diameter (mm) [inches] (mm) [inches] Antenna – mast distance Material of clamp and screws Weight (kg) [lb] 42 – 115 [1.65 – 4.53] 20 – 25 [0.79 – 0.98] Hot-dip galvanized steel / stainless steel 1.1 [2.43] 100 [3.94] 40 [1.57] 40 [1.57] 72 [2.83] 20–25 [0.79–0.98] 152 [5.98] 15 2–1 4 4.53] 5– [1.6 M10 MA = 25 Nm 35 [1.38] M8 MA = 20 Nm 64 [2.52] 125 [4.92] 936.3920/c Subject to alteration. 20–25 [0.79–0.98] Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com All dimensions in mm and [inches] 738546 Page 1 of 1 FlexRET A flexible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas. ● ● Compliant to AISG 1.1 and 3GPP/AISG 2.0 Single RETs or Multi RET displayed Protocols Logical interface ex factory 1) Operates as Ex factory Input voltage range V Power consumption W Connectors Hardware interfaces Housing material Weight Packing size (H x W x D) Dimensions (H x W x D) ● Daisy Chain feasibility Pre-configurated 86010153 Type No. Adjustment time (full range) Adjustment cycles Temperature range Protection class Lightning protection ● sec °C g lb mm inches mm inches compliant to AISG 1.1 and 3GPP/AISG 2.0 3GPP/AISG 2.0 Single RETs or Multi RET Single RETs 10 ... 30 (pin 1, pin 6) < 0.5 (stand by); < 10 (motor activated) 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: female RS 485A/B (pin 5, pin 3); power supply (pin 1, pin 6); DC return (pin 7); according to AISG / 3GPP 40 (typically, depending on antenna type) > 50,000 –40 … +60 IP 24 (installed) AISG interface (each pin) 2.5 kA (10/350 µs) 8 kA (8/20 µs) Profile: Aluminum anodized; cover: Aluminum die cast coated 350 0.77 245 x 93 x 102 9.6 x 3.6 x 4 142 x 71 x 50.4 5.6 x 2.8 x 2 1) The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 with a vendor specific command. Start-up operation of the FlexRET is only possible in a RET system supporting 3GPP/AISG 2.0! 1) Please note: If the Primary which controls the FlexRET system does not support the default ex-factory interface setting, then the RCU must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. 936.4643/b Subject to alteration. If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna after power on automatically. It is not necessary to configurate the FlexRET manually. Standards: EN 60950-1 (Safety) EN 60950-22 (Safety – Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1st edition Certification: CE, FCC Scope of supply: FlexRET Optional: Site Sharing Adapter (86010154 or 86010155) to create independent logial interfaces at one antenna or site. Makes it possible to operate with more than one independent Node B. Please note: In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1). The respective information can be found on the site documentation which is included in the scope of supply. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com 86010153 Page 1 of 4 FlexRET Startup of FlexRET The FlexRET module included in the antenna is preconfigured with the following information: Antenna model no., Antenna Serial no., Antenna configuration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will find the FlexRET. You only need to insert your additional data. Connecting the control cables: Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for fixing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or by a special torque screw driver (order no. 85010080). See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only. Please note: If the daisy chain output is not used, do not remove the protection cap. 936.4643/b Subject to alteration. For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU. Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device. Page 2 of 4 86010153 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com FCC – Statements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ubject to alteration. &++. 936.4643/b %'(#)%%'!()$#$'"*- = #*()'#%%!!(*-%%'!('$ -"%)(!#4 =-%!$))$#()*)$'(*-*-$#)$#((*+#)(39A:!=%%'!# $)%(%'$*''$*!!2)9B:!=*)!()*'!=%%'!$)%)')$*)'$*!! '$!)'&*(*2""(!'$*!!()(*(%)!=#$"%'$"))'!$#)$##"#)4 (!(()!%%')*($"%!(,)## 7@@C4 )%%'!#*"'&*!!((()$#$'"!#$'" 7@@C*#4 *,/%-,( !!!) ;#.<#($'"$)$#(#$)-%'((!.%%'$+.)%').'(%$#(!$'$"%!#$*! +$)*('5(*)$').)$$%'))&*%"#)4 86010153 Page 3 of 4 Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com FCC – Statements Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: Kathrein USA Address: Greenway Plaza II 2400 Lakeside Blvd. Suite 650 Richardson, Texas 75082 Telephone: (01+) 214.238.8800 Type of equipment: 936.4643/b Subject to alteration. Model Name: FlexRET FCC ID SP3-86010153 Page 4 of 4 86010153 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com