i SIZE DWG NO SH 123E4888 REV A REVISIONS REV DATE DESCRIPTION UPD'D REV STATUS OF SHEETS, "SEPARATOR" A WAS "SAPARATOR" AND "CENTRIFUGE" WAS "CETRIFUGE" 2 PLACES ( G - 4 ) . H APPROVED 03-01-22 KJO H REVISE ON CAD ONLY UG PART; 123E4888.PRT MECHANICAL PIPING, INSTRUMENT SUPPLY OR CONNECTION TO PROCESS REDUCER ORIFICE PLATE S SEPARATOR MANUAL DRAIN (NOTE TYPE CENTRIFUGE, CYCLONE, OR ELECTROSTATIC PRECIPITATOR) GUARDED OIL LINE MECHANICAL LINK QUICK DISCONNECT COUPLING DESSICANT DRYER < ~ _ > BREAKDOWN ORIFICE ELECTRIC HEAT TRACED LINE SIGHT GLASS FLOOR DRAIN \7 VACUUM BREAKER S SEPARATOR AUTOMATIC DRAIN (NOTE TYPE CENTRIFUGE, CYCLONE, OR ELECTROSTATIC PRECIPITATOR) RECEIVER STEAM HEAT TRACED LINE ^7; DIRECTION ^ -7 - /- -/ & • — /- 7 -7 ^ — 7 /- ^ OF FLOW TANK UNDEFINED SIGNAL (TO BE DEFINED BY USER) V B BELL-UP (ABOVE GROUND) CLEAN OUT GAS SEPARATOR V PNEUMATIC SIGNAL FLAME ARRESTOR ELECTRICAL SIGNAL h—b V /\ h \^L 7\ * SUMP TANK HYDRAULIC SIGNAL 1 1 hOH CENTRIFUGATION UNIT WASTE CONE DRIVE COUPLING r^ CAPILLARY-FILLED SIGNAL LINE VENT ENCLOSURE, COMPONENT, OR PACKAGE BOUNDARY HEATER (NOTE MEDIUM TYPE) DRAIN FUNNEL F OIL RESERVOIR F I L L •^ COOLER EUECTOR LINES DO NOT UOIN r\. r^ \ ^ M^ DEDICATED EQUIPMENT GROUNDING LUG EYE WASH PLUGGED PORT ^MH3 ELECT BAYONET DESUPERHEATER BLIND FLANGE INTERNAL COIL ISOLATING COUPLING CAPPED PI TOT TUBE BAYONET FLANGE SPRAY NOZZLE T PIPE PLUG I w KWWH END OF LINE FILTERXSTRAINER F=FILTER S=STRAINER TEMP=TEMPORARY w* CO GEAR BOX TRAP FILTER ANDXOR REGULATOR AUXILARY STEAM TURBINE LINE TERMINATES AT RESERVOIR (NOTE ABOVE OR BELOW FLUID LEVEL) GLAND CONDENSER UU AIR COOLED EXCHANGER LINES UOINED X ) C SYPHON FLEXIBLE HOSEXLINE EXPANSION UOINTXCOUPLING N' ir> DUPLEX FILTERXSTRAINER F=FILTER S=STRAINER TEMP=TEMPORARY /^\ ACCUMULATOR DIFFUSER X SILENCER VENTURI # # # # # 1 BY OTHERS GE SUPPLY ACCUMULATOR GAS CHARGED STRAINER, WITCH'S HAT FLOW NOZZLE SCOPE BOUNDARY m to Y-STRAINER ^ PRESSURE GAUGE DIAPHRAGM SEAL PIT # # # # # INTERFACE POINT EXAMPLE MSOOl OR OOOOl A m PRESSURE GAUGE SNUBBER DAMPER OR LOUVER GAS BOTTLE N © COPYRIGHT 2002 GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINS PROPRIETARY INFORMATI ON OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC COMPANY. UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ON: 2 PL DECIMALS ± 3 PL DECIMALS ± ANGLES ± FRACTIONS ± 00 00 00 SIGNATURES DRAWND LUCARELLI DT- IN A A A 5 4 3 2 A DATE GE Power Generab 02-06-12 i on REV SH REV STATUS OF SHEETS GENERAL ELECTRIC COMPANY GAS TURBINE Schenectady, NY CHECKED ENGRG P&ID ISSUED SYMBOLS FIRST MADE FOR STANDARD APPLIED PRACTICES 348A9200 SIZE SIM TO: T A SCALE CAGE CODE DWG NO 123E4888 SHEET > i SIZE DWG NO 123E4888 SH 2 REV A REVISIONS REV DESCRIPTION DATE ADDED ORIFICE I E - 8 ) , "RECIRCULATION" WAS "RECICULATION" I E - 4 1 , UPD'D VALVES ( D - 8 , 03-01-22 A D-5 & C - 5 ) , UPD'D FLOW DIVIDER I E - 3 ) , UPD'D ARROWS TO BE FILLED ( B - 8 ) . H APPROVED KJO REVISE ON CAD ONLY UG PART? 123E4888.PRT X GATE VALVE IXI GLOBE VALVE BALL VALVE M MOTOR OPERATED LEVEL REGULATOR FLOAT ACTUATED XM S SOLENOID OPERATED G GEAR OPERATED -JcM CHECK VALVE rE5Z3- * BACK PRESSURE EXTERNAL TAP PATH D TO B, A TO C ON LOSS OF POWER PRESSURE REDUCING EXTERNAL ANNUBAR SPRING OPPOSED DIAPHRAGM OR ACTUATOR FUNCTION CHECK VALVE EXCESS FLOW V GRADE PRESSURE REDUCING SELF-CONTAINED </ PRESSURE BALANCED NON RETURN VALVE Q CYLINDER ACTUATOR BACK PRESSURE SELF-CONTAINED VALVE WITH DRILLED ORIFICE P VS ADJUSTABLE ORIFICE ORIFICE OR SNUBBER, PLUG TYPE, INTERNALLY DRILLED OR POROUS HAND ACTUATOR OR HAND WHEEL ^ JL AUTOMATIC & FL FC FO FLOW DIVIDER GEAR TYPE & PRESSURE COMPENSATED ORIFICE ANGLE STOP CHECK VALVE ^ RECIRCULATION VALVE FAIL LOCKED (FAIL LAST) ^Lr- FAIL CLOSED AUTOMATIC VENT (AIR RELEASE) V FAIL OPEN EXTENDED DISCHARGE LC LOCKED CLOSED VACUUM * FOUR WAY VALVE PRESS PRESSURE AND VACUUM RELIEF TRANSPORTATION NO NORMALLY OPEN PRESSURE RELIEF C _y PLUG OR COCK VALVE NC NORMALLY CLOSED NT NORMALLY THROTTLING THREE-WAY PLUG VAVLE FOOT VALVE c _> X T> SELECTOR VACUUM RELIEF X TRANSFER, 6 PORT r_> RUPTURE DISK PRESSURE RELIEF MAIN STEAM STOP VALVE i DIAPHRAGM VALVE ALARM BELL LINEAR VARIABLE LOCKED OPEN NEEDLE VALVE ^ o AB X T> LO ^Z CLUTCH INITIAL DISCHARGE THREE WAY VALVE V VACUUM SERVICE DIFFERENTIAL PRESSURE REGULATOR SPRING ACTUATOR ANGLE VALVE POST HOSE REEL COUNTERWEIGHT T DRAIN TO GRADE INDICATOR VALVE BUTTERFLY VALVE ^A PATH A TO C ON LOSS OF POWER B C PNEUMATIC OPERATED £ ^ < ^ A MANIFOLD RUPTURE DISK VACUUM RELIEF © COPYRIGHT 2002 GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINS PROPRIETARY INFORMATI ON OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC COMPANY. T J\ IS V GENERAL ELECTRIC COMPANY GAS TURBINE S c h e n e c t a d y , NY GE Power DRAWN G&n&rat SIZE LUCARELLI ISSUED D LUCARELLI DWG NO 123E4888 ion D CAGE CODE SCALE SHEET i SIZE DWG NO 123E4888 SH 3 REV A REVISIONS DESCRIPTION REV UPD'D ARROWS TO BE FILLED (C-8, D-8), ADDED PUMP IG-6). A H DATE APPROVED 03-01-22 KJO REVISE ON CAD ONLY UG PART? 123E4888.PRT PUMP, VARIABLE DISPLACEMENT PRESSURE COMPENSATED PUMP, POSITIVE DISPLACEMENT PUMP, VARIABLE DISPLACEMENT PUMP, TURBINE DELUGE VALVE PIGTAIL HOSEHEAD SOURCE/DESTI NAT I ON ARROW, ARROW POINTS IN DIRECTION OF NORMAL FLOW DELUGE SYSTEM H PUMP, VERTICAL PILOT LIGHT PUMP, CENTRIFUGAL FOAM CHAMBER MOTOR, PNEUMATIC, UNIDIRECTIONAL PUMP, METERING ^ MOTOR, PNEUMATIC, BI-DIRECTIONAL PATCHBOARD POINT (ANNUNCIATOR, DATA LOGGER INTERFACE PANEL) v EXTENDED DISCHARGE FP C02 NOZZLE INSTRUMENTS SHARING MULTIFUNCTION DEVICE IN COMMON HOUSING FAN v MOTOR, HYDRAULIC, UNIDIRECTIONAL MOTOR, HYDRAULIC, BI-DIRECTIONAL \- INITIAL DISCHARGE FP C02 NOZZLE BLOWER COMPRESSOR TURBINE OR PROPELLER TYPE FLOW ELEMENT FIRE PROTECTION WATER SPRAY NOZZLE MOTOR, NO SPACE HEATER PUMP PNEUMATIC, FIXED DISPLACEMENT COMPRESSOR DIAPHRAGM SEAL MOTOR, WITH SPACE HEATER X£y FIRE HOSE GATE VALVE [XD- FIRE HOSE GLOBE VALVE POSITIVE DISPLACEMENT TYPE FLOW TOTALIZING INDICATOR PUMP PNEUMATIC, FIXED DISPLACEMENT VACUUM PURGE OR FLUSHING DEVICE FIRE HOSE ANGLE VALVE GENERIC STACK PUMP HYDRAULIC, FIXED DISPLACEMENT UNIDIRECTIONAL ^ W V I REST FOR LATCH-TYPE ACTUATOR FIRE HOSE STATION UNDEFINED INTERLOCK LOGIC PUMP HYDRAULIC, FIXED DISPLACEMENT BI-DIRECTIONAL F ELECTRO-PNEUMATIC CONVERTER SELF SUPPORTING STACK FIRE HYDRANT WITH HOSE HOUSE PUMP-MOTOR, HYDRAULIC, VARIABLE OPERATING IN ONE DIRECTION AS A PUMP OPERATING IN THE OTHER DIRECTION AS A MOTOR PUMP-MOTOR, HYDRAULIC, VARIABLE OPERATING ONE DIRECTION OF FLOW AS EITHER A PUMP OR AS A MOTOR FUSIBLE LINK VALVE FI VARIABLE AREA FLOW INDICATOR FIRE HYDRANT LEVEL INDICATOR FLOAT TYPE DERRICK SUPPORTED STACK VOLUMETRIC PUMP DIRECT CURRENT m ALTERN- CURRENT N to m MANUAL PUMP oo oo oo GUYED STACK Ui > © COPYRIGHT 2002 GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINS PROPRIETARY INFORMATI ON OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC COMPANY. T J\ IS V GENERAL ELECTRIC COMPANY GAS TURBINE S c h e n e c t a d y , NY GE Power DRAWN G&n&rat SIZE LUCARELLI ISSUED D LUCARELLI DWG NO 123E4888 ion D CAGE CODE SCALE SHEET i SIZE DWG NO 123E4888 SH 4 REV A REVISIONS REV DATE DESCRIPTION ADDED HYDRAULIC SYMBOL ( F - 7 ) , UPD'D PNEUMATIC SYMBOL ( F - 7 1 , UPD'D ARROWS TO A BE FILLED I E - 7 1 , DEL'D TWO EXAMPLE 03-01-22 HYDRAULIC CONTROL VALVES I B - 5 ) & UPD'D REST. H APPROVED KJO H REVISE ON CAD ONLY UG PART? 123E4888.PRT EXAMPLE HYDRAULIC CONTROL VALVES HYDRAULIC CONTROL VALVES l\A/ HVAC SYMBOLS f HYDRAULIC RELIEF VALVE 2 POSITION, 2 WAY, AIR BLEED HYDRAULIC PRESSURE REDUCING VALVE NA/ » i — DAMPERS SILENCER SPRING RETURN _L IWI 2 POSITION, 2 WAY, SOLENOID OPERATED SPRING RETURN A \ T MANUALLY OPERATED LOUVERS S///// / / / / - 2 POSITION, 3 WAY, MANUALLY OPERATED, SPRING RETURN (TWO PRESSURE) SOLENOID OPERATED w V _L " \ PILOT OPERATED PNEUMATIC FIXED LOUVERS DUCT 2 POSITION, 3 WAY PILOT OPERATED, SPRING RETURN PILOT OPERATED HYDRAULIC DUCT FLANGE SERVO OPERATED J_ ± \ \N\ T . 2 POSITION, 3 WAY ACTUATOR DUMP FIXED RESTRICTOR ± INFINITE POSITION REDUCER yf 2 POSITION, 3 WAY AIR TRIP RELAY I '•'v _l_ ) ( 1 T 1 ' 1 _L _L V X 1 f \ w rr TYPICAL 2 WAY . T ill 2 POSITION, 6 WAY TRIP RELAY ELBOW 2 POSITION, 4 WAY, SOLENOID OPERATED SPRING RETURN TYPICAL 3 WAY HOOD A 2 POSITION, 4 WAY PILOT OPERATED, SPRING RETURN TYPICAL 4 WAY !! SCREEN T T 2 POSITION, 4 WAY RELAY TRIP TYPICAL 5 WAY K 2 POSITION, 4 WAY RELAY DUMP h/V III HEATER TYPICAL 6 WAY FAN BLOWER XT h/V *r T T 3 POSITION, 4 WAY SERVO OPERATED, SPRING RETURN m XT T T 1 X *r m CLOSED CENTER 4 WAY INFINITE POSITION, SERVO AT NULL to N m oo oo oo -N > © COPYRIGHT 2002 GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINS PROPRIETARY INFORMATI ON OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC COMPANY. T J\ IS V GENERAL ELECTRIC COMPANY GAS TURBINE S c h e n e c t a d y , NY GE Power DRAWN G&n&rat SIZE LUCARELLI ISSUED D LUCARELLI DWG NO 123E4888 ion D CAGE CODE SCALE SHEET 4 i SIZE DWG NO 123E4888 REV SH 5 A REVISIONS REV DESCRIPTION A "TRANSMITTER" WAS "TRANSMIT" (E-5). H DATE APPROVED 03-01-22 KJO REVISE ON CAD ONLY UG PART? 123E4888.PRT INSTRUMENT IDENTIFICATION SUCCEEDING LETTERS FIRST LETTER MEASURED OR INITIATING VARIABLE A ANALYSIS B C BURNER, COMBUSTION USER'S CHOICE D USER'S CHOICE E VOLTAGE F FLOW RATE G IN SERVICE H HAND I J K L READOUT OR PASSIVE FUNCTION MODIFIER USER'S CHOICE CONTROL DIFFERENTIAL SENSOR RATIO (PRIMARY ELEMENT) EXERCISE FUNCTION (FRACTION) GLASS, VIEWING DEVICE ELECTRICAL GROUND HIGH CURRENT INDICATE (ELECTRICAL) POWER TIME, TIME SCHEDULE SCAN TIME RATE OF CHANGE CONTROL STATION N USER'S CHOICE USER'S CHOICE 0 USER'S CHOICE PRESSURE, VACUUM ORIFICE, RESTRICTION LIGHT POINT U MULT I VARIABLE V VIBRATION, USER'S CHOICE TRIP CIRCUIT FUNCTION EXAMPLES DEVICE PANEL LOCATION & SIGNAL DESTINATION TABLES (TEST) CONNECTION INTEGRATE, TOTALIZE RECORD SPEED, FREQUENCY TEMPERATURE LOW MIDDLE, INTERMEDI ATE MOMENTARY QUANTITY RADIATION S T DEVICE LOCATION REFo (SET POINT) SWITCH SAFETY LOCATION NUMBER TRANSMITTER MULTIFUNCTION w WEIGHT, FORCE X UNCLASSIFIED X-AXIS Y EVENT, STATE Y-AXIS WELL UNCLASSIFIED MULTIFUNCTION (PANEL ONLY) PANEL DESCRIPTION 1 2 3 UNCLASSIFIED UNCLASSIFIED ETC, RELAY, COMPUTE, CONVERTER OR PRESENCE POSITION, DIMENSION MULTIFUNCTION VALVE, DAMPER, LOUVER MECHANICAL ANALYSIS z MODIFIER USER'S CHOICE USER'S CHOICE M R OUTPUT FUNCTION ALARM LEVEL USER'S CHOICE P Q H Z-AXIS DEVICE SIGNAL DRIVE, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT LOCATION LETTER (DESTINATION ONLY) SIGNAL DESTINATION A B INSTRUMENT SYMBOLS AND DESIGNATIONS C NORMALLY ACCESSIBLE DEVICES OR FUNCTIONS ETC, SHOWN WITH SOLID HORIZONTAL BAR, PRIMARY LOCATION DISCRETE INSTRUMENTS e FIELD MOUNTED o AUXILIARY LOCATION e NORMALLY INACCESSIBLE DEVICES OR FUNCTIONS SHOWN WITH DASHED HORIZONTAL BAR PANEL LOCATION OF DEVICEi 1 (SEE TABLE) SIGNAL DESTINATIONS C (SEE TABLE) SHARED DISPLAY, SHARED CONTROL COMPUTER FUNCTION e o e EXAMPLES DEVICE DEFINITION FROM TABLES ISTs " P " PRESSURE, 2ND? " T " TRANSMITTER ITEM NO,? " 4 0 0 " (PT400 = DESCRIPTION) DEVICE BALLOON TYPEs "PRIMARY LOCATION LINETYPEs "INSTRUMENT SUPPLY" CODE MAY BE ORIENTED ANYWHERE AROUND DEVICE SYMBOL PERIMETER m 99 BALLOON INSTRUMENT ITH THERMOWELL to N m PROGRAMABLE LOGIC CONTROL O / \ oo oo oo SURFACE-MOUNTED TEMPERATURE SENSOR 01 > © COPYRIGHT 2002 GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINS PROPRIETARY INFORMATI ON OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC COMPANY. T J\ IS V GENERAL ELECTRIC COMPANY GAS TURBINE S c h e n e c t a d y , NY GE Power DRAWN G&n&rat SIZE LUCARELLI ISSUED D LUCARELLI DWG NO 123E4888 ion D CAGE CODE SCALE SHEET