AND LOGIC L1 SW 1(N.O) SW 2(N.O) Lump SW1 only turned on lamp will be no light. SW2 only turned on lamp will be no light. When both SW1 AND SW2 are turned on lamp will be light. OR LOGIC L1 SW 1(N.O) SW 2(N.O) Lump When SW1 OR SW2 are turned on lamp will be light. NOT LOGIC SW 1(N.C) L1 Lump When SW1 is NOT turned off lamp will be light. NAND LOGIC SW 1(N.C) SW 2(N.C) L1 Lump When SW1 is NOT turned off lamp will be light. When SW2 is NOT turned off lamp will be light. When both SW1 AND SW2 NOT turned off lamp will be light. NOR LOGIC SW 1(N.C) SW 2(N.C) L1 Lump When SW1 is turned off lamp will be NO light. When SW2 is turned off lamp will be NO light. When SW1 OR SW2 turned off will be NO light. ON-DELAY LOGIC T1 SW 1(N.O) Timer 〇sec L1 T 1(N.O) Lump When SW1 turned on T1(timer) will be working. After timer count up(ON-DELAY) L1 will be light. OFF-DELAY LOGIC SW 1(N.O) T 1(N.C) R1 R 1(N.O) Timer 〇sec T1 L1 Lump When SW1 turned on R1(relay) will be working then hold to T1 and L1. After timer count up(OFF-DELAY) L1 lighting will be turn off. PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 1. When press to PB1 How working each device? U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 L2 T2 TH Motor Mg2 PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 1. Press to PB1 2. Magnetic contactor1 activate Lump1 righting Timer1 activate U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 L2 30sec T2 TH Motor Motor turn to ahead PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 3. Mg1 contactor activate (NO close : NC open) 1)Self-holding U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 L2 30sec T2 TH Motor Motor turn to ahead PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 4. During motor turn to ahead press to PB3 2)Interlock working then can not start Astrn U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn to ahead PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 4. During motor turn to ahead press to PB2 Mg1 : off , L1 : off , T1 : off , Mg1 contact off 5. Stop motor turning (ahead) U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn is stop PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 6. When over load 1)TH NC contact active U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn to ahead PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 7. During motor turn to ahead TH active Mg1 : off , L1 : off , T1 : off , Mg1 contact off 8. Stop motor turning (ahead) by 3) Safety interlock(TH) U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 3)Safety Interlock L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn is stop PB3 : On for AH PB4 : Off for AH Mg2 : Magnetic contactor for AS L2 : Lump for AS T2 : Timer number 2 PB1 : On for AH PB2 : Off for AH Mg1 : Magnetic contactor for AH L1 : Lump for AH T1 : Timer number 1 9. After 30sec. 1)T1 active U PB1 PB2 Mg2 TH V W T1 Mg1 Mg1 3)Safety Interlock L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn to ahead PB3 : On for AH PB1 : On for AH PB4 : Off for AH PB2 : Off for AH Mg2 : Magnetic contactor Mg1 : Magnetic contactor for AS for AH L2 : Lump for AS L1 : Lump for AH T2 : Timer number 2 T1 : Timer number 1 4) Self kill circuit PB1 PB2 Mg2 TH T1 10. During motor turn to ahead T1 active Mg1 : off , L1 : off , T1 : off , Mg1 contact off 8. Stop motor turning (ahead) by 4) Self kill circuit (T1) U V W Mg1 Mg1 3)Safety Interlock L1 1)Self-holding 30sec T1 PB3 PB4 Mg1 TH Mg1 T2 Mg2 Mg2 Mg2 2)Interlock L2 30sec T2 TH Motor Motor turn is stop