EQ..n Moving Panel Meters PQ..nIron Moving Coil Panel Meters Description Moving iron panel meters, EQ 48/72/96/144 n sizes are suitable for measurement of AC current & voltage in usual frequency range of 15 - 100 Hz & above 100 Hz. EQ..n meters are protected from breakage under adverses condition because of it suspended between spring loaded saphire jewl & critical damped using. Silicon oil which protect meters from breakage under adverse condition Features 1. Housed in glass filed polycarbonate cases. 2. Indicates true RMS value practically independent of waveform even of high harmonics. 3. Large torque to weight ratio which assures a long life of instrument. 4. Standard terminal covers IP 10. Complete protection cover on request. 5. CT operated meters has onsite interchangeable scale facility. Provision for easy replacement of front window, glass & bezel. Applicable Standards Nominal case & cutout dimensions for DIN 43700 indicating Electrical instruments Scale& pointer fo r electrical measuring instruments DIN 43802 Connections and Terminal markings for panel meters DIN 43807 Terminal bolts / leads. DIN 46200/46282 Safety requirements and protective measures for Electrical indicating. instruments and their accessories. DIN 40050/8-70, VDE 0110/ 11-72 VDE 0410/ 10-76 IEC 529 , IEC 1010 Performance specifications for direct acting indicating analogue electrical measuring instruments & their accessories IEC51/DINEN60051 DIN 43701 Environmental conditions VDE / VDI 3540 Front frames for indicating measuring instruments Principle dimensions DIN 43718 UL Combustibility Class UL 94 V-0 Comply with following European directives 89 / 336 / EEC (EMC Directive),73/23/EEC (low voltage directive) & ammemdment 93/68/EEC, For CE Marking. Accuracy at Reference Conditions Scale and Pointer Pointer deflection Scale characteristics Scale length over range: 0 0...90 Knife - edge pointer Near Linear above 10% of nominal full Scale value with coarse fine division Ammeters voltmeters for use on Voltage transformer EQ 48n EQ 72n EQ 96n EQ 144n 41mm 61mm 97mm 146 mm 2 times nominal current 1.2 times nominal voltage Scale Interchangeability Interchangeable Accuracy class 1.5 according to IEC 51/ DIN EN 60051 Reference conditions Ambient temperature Position of use Input Wave form Frequency: Other conditions Rated value of measured quantity sine wave, distortion factor <= 5% 45...65HZ IEC 51/ DIN EN 60051 Barthelsmühlring, 16, D - 76870 Kandel, GERMANY. Tel. : + 49 7275-9883-0 Fax: +497275-9883-33 E-mail : info@celsagermany.com Web : www.celsagermany.com EQ..n Moving Panel Meters PQ..nIron Moving Coil Panel Meters MechanicalSpecifica tion Case details Moulded square case suitable for mounting in Control/ Switchgear panels, Machinery consoles. Case material Glass filled polycarbonate, with non drip& flame retardant property as per UL 94 V-0 Standard Measuring Ranges A. C. Voltage A. C. Current 6V 100mA 10V 150mA 15V 250mA 25V 400mA 40V 600mA Front facia Glass 60V 1A Position of use Vertical 100V 1.5A Panel fixing Side clamp 120V 2.5A Mounting Stackable in a single cutout 132V 3A Panel thickness < 40 mm 150V 4A 200V 5A 250V 6A 300V 10A 400V 15A 500V 20A 600V 25A 750V (except EQn48) 30A Terminals Voltmeters and ammeters <= 30A Hexagon studs, M4 screws and wire clamps E3 (DIN 46282) Ammeters > 30A Threaded studs M6 with Nuts. Ammeters > 60A Threaded Studs M8 with Nuts. Electrical Specification 40A 50A Measured quantity AC voltage or current For use on voltage transformer Power consumption: voltmeters Ammeters < 15A Ammeters > 15A < 4.5VA < 0.5VA < 0.8 VA .../100V secondary 100A(except EQ48n) .../110V secondary for use on current transformer .../1A secondary or .../5A secondary 60A Overload capacity (acc. to IEC 51) Continuously 1.2 times rated voltage /current Short duration Voltmeters Ammeters 5 s max. 1 s max. Enclosure code (IEC 529) Environmental Conditions 2 times rated voltage max 1000V, upto max5 second. EQn 48 EQn 72/96/144 10 times(200 A max). 10 times -40 times (250A max.) IP 52 case IP 00 for terminals without back cover IP 20 for terminals with back cover Insulation class Group A according to VDE 0110 Rated insulation voltage EQ48n:660V EQ..n 72/96/144: 1000V Proof voltage EQ48n: 2kV EQ..n 72/96/144: 3kV Installation category 600 V CAT III (IEC 1010) Insulation resistance > 50 M W at 500V d.c Climatic suitability Climate category II as per climatic class 3 according to VDE/VDI 3540 Operating temperature Ambient Temperature - 10... + 55 C o 0...50 C Storage temperature Relative humidity - 25... + 65 C < 75% annual average, non-condensing 15g. 11 ms 1.5 g at about 50 Hz o o Shock resistance Vibration resistance o Position of use Frequency External magnetic field: Vertical +-5 15 ...100Hz (Voltage) 15...400Hz (current) At 0.4 kA/m,less than 6 % of fiducialvalue(not as a percentage class index) Barthelsmühlring, 16, D - 76870 Kandel, GERMANY. Tel. : + 49 7275-9883-0 Fax: +497275-9883-33 E-mail : info@celsagermany.com Web : www.celsagermany.com EQ..n Moving Panel Meters PQ..nIron Moving Coil Panel Meters Options Dimensions Case :Front facia Colour of bezel Red index pointer Antiglare glass Red, Yellow ,Blue, White, Grey Front adjustable on site o On request 15 ....165 Position of use Colour of pointer Blank dial Special markings Yellow and White With initial and end values marked. Numbering / Lettering. Division dials Basic divisions without numbering. Colour markings/bands Red or green 144n 1 44 136 Accuracy class Over range (ammeters) 1 on request No over range or 6 times over range over nominal current 53 1 3 7 .5 Accessories 5.5 Safety Terminal Protection 138 Protection back cover to provide protection against accidental contact (hand and fingers) acc. to VDE 0410. Ordering Information Moving-iran panel meter Front dimension 48,72,96 and 144 48 mm x 48 mm 96 mm x 96 mm Over range (ammeters) no over range *3 2 times nominal current 6 times nominal current Measuring Ranges Refer to table inside Terminal protection Terminal cover Back cover 72 mm x 72 mm 144 mm x 144 mm AC Voltage (Direct connected) *1 *3 Panel Fixing Side clamp Red Index Pointer None *3 Front facia Black *1 Red, Blue, Yellow, White *3 Colour of bezel Black *1 Red, Blue, Yellow, White *3 Position of use Vetical *1 On request 15... 165 0 *3 Dial Standard scale same as measuring range Blank dial with division *3 Additional letering on request *3 Additional numbering on request *3 Coloured merking red or green *3 Coloured sector red or green *3 *1 *3 0.4 kg. Connections Type EQn Logo +1 17 L1 N(L2) X AC Current (Direct connected) 17 18 L1 N(L2) X AC Current (for use on current Transformer) 17 k CELSA Standard Please clearly add the desired specifications while ordering 18 L1 N(L2) k 18 l L X Ordering example Eqn 72 Measuring range 150 V, dial 0 - 150V Barthelsmühlring, 16, D - 76870 Kandel, GERMANY. Tel. : + 49 7275-9883-0 Fax: +497275-9883-33 E-mail : info@celsagermany.com Web : www.celsagermany.com