Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Typical applications include corridors, lobbies. CONSTRUCTION — Galvanized steel mounting/plaster frame; galvanized steel junction box with bottomhinged access covers and spring latches. Vertically adjustable mounting brackets with commercial bar hangers provide 3-3/4" total adjustment. Cchannel T-bar fastener options available. Two combination ½"-3/4" and four ½" knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out). No. 12 AWG conductors, rated for 90°C. Accommodates 12"-24" joist spacing Passive cooling thermal management; light engine and drivers are accessible from above or below ceiling Max ceiling thickness 1-1/2" OPTICS — LEDs are binned to a 3-step MacAdam Ellipse; 80 CRI minimum. Diffusing lens covers optical chamber General illumination 1.0 S/MH 55° cutoff to source and source image Self-flanged anodized reflectors in specular, semi-specular, or matte diffuse finishes. UGR — UGR is zero for fixtures aimed at nadir with a cut-off equal to or less than 60deg, per CIE 117-1996 Discomfort Glare in Interior Lighting. ELECTRICAL — Multi-volt 0-10V dimming available. 0-10V dimming drivers mounted to junction box, 10% or 1% minimum dimming level 0-10V dimming fixture requires two (2) additional low-voltage wires to be pulled LUMEN MAINTENANCE — 70% lumen maintenance at 50,000 hours LISTINGS — Certified to US and Canadian safety standards. Damp location standard (wet location, covered ceiling optional). Drivers are RoHS compliant. BUY AMERICAN ACT — Product with the BAA option is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations. Please refer to www.acuitybrands.com/buy-american for additional information. Type LDN8 STATIC WHITE 8" Open and Wallwash LED Non-IC New Construction Downlight WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. PERFORMANCE DATA WATTAGE CONSUMPTION MATRIX Nominal Lumens @ 3500K 5000 6000 8000 Polar Candela Distribution 180° 170° 16,000 Delivered Lumens 5353 6138 8520 160° Polar Candela Distribution 150° 140° Wattage 10,667 LPW 61.1 73 84.1 92.1 92.5 10582 118.83 12506 148.7 84.1 15000 16025 184.5 86.9 20000 20707 265.4 78.0 130° 120° 7,500 5,000 110° 2,667 100° 2,500 100° 0.00 90° 0.00 90° 2,667 80° 2,500 80° 5,333 70° 5,000 70° 60° 7,500 60° 10,000 13,333 50° 16,000 12000 VA: 0° 10° 20° 30° 40° - 0° H - 90° H 12,500 50° 15,000 VA: Open 10° 20° 30° 40° Wallwash 5000lm-6000lm below 157 [40.4] 8 13 81 4 [20.9] 816 [22.3] MABL IM E D 0° - 0° H - 90° H DIMENSIONS battery pack 140° 110° 8,000 89.1 150° 5,333 10,667 10000 160° 12,500 10,000 120° 8,000 87.6 180° 170° 15,000 130° 13,333 TM 11 [42.4] 1616 Aperture: 8 58 (21.9) Ceiling Opening: 8 43 (22.2) See page 4 for other fixture dimensions DOWNLIGHTING LDN8 LDN8 ORDERING INFORMATION Example: LDN8 35/50 LO8 AR LSS MVOLT EZ1 Lead times will vary depending on options selected. Consult with your sales representative. LDN8 Series LDN8 Color temperature Lumens 8" round 27/ 30/ 35/ 40/ 2700K 3000K 3500K 4000K 50 60 80 100 120 150 200 Driver Emergency ‡ GZ10 0-10V driver dims to 10% GZ1 0-10V driver dims to 1% EZ1 0-10V eldoLED driver with smooth and flicker-free deep dimming performance down to 1% (blank) EL ELR ELSD ELRSD E10WCP E10WCPR E10WRSTAR Option value LDN8 WR, BR 347V SF TRW, TRBL NPP16D, NPP16DER, NPS80EZ, NPS80EZER N80 NLTAIR2, NLTAIRER2 Reloc® Options RRLAE RRLC12S TRALTBD, FRALTBD TCPC, FCPC 5000 lumens 6000 lumens 8000 lumens 10000 lumens 12000 lumens 15000 lumens 20000 lumens Trim Style Trim Color Trim Finish Flange Color ‡ Voltage LO8 LW8 AR WR ‡ BR ‡ TCPC ‡ LSS Semi-specular LD Matte diffuse LS Specular TRW TRBL FCPC FRALTBD MVOLT 120 277 347 ‡ Downlight Wallwash No Emergency Needed Battery pack (10W constant power), non-T20 compliant, integral test switch Battery pack (10W constant power), non-T20 compliant, remote test switch Self-diagnostic battery pack (10W constant power), non-T20 compliant, integral test switch Self-diagnostic battery pack (10W constant power), non-T20 compliant, remote test switch Battery pack (10W constant power), T20 compliant, integral test switch Battery pack (10W constant power), T20 compliant, remote test switch Emergency battery pack, 10W with remote test switch and Iota STAR technology Clear White Black Custom painted trim TRALTBD ‡ RAL painted trim White painted flange Black painted flange Custom painted flange only RAL painted flange only Multi-volt 120V 277V 347V Control Input ‡ Options (blank) JOT NPP16D HAO ‡ High ambient option (40°C) CP ‡ Chicago Plenum RRL__ RELOC®-ready luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Refer to RRL for complete nomenclature. Available only in RRLA, RRLB, RRLAE, and RRLC12S. BAA Buy America(n) Act Compliant 90CRI High CRI (90+) SF ‡ Single fuse No Control Input Needed Wireless room control with “Just One Touch" pairing nLight® network power/relay pack with 0-10V dimming for non-eldoLED drivers (GZ10, GZ1). NPP16DER nLight® network power/relay pack with 0-10V dimming for non-eldoLED drivers (GZ10, GZ1). ER controls fixtures on emergency circuit. NPS80EZ nLight® dimming pack controls 0-10V eldoLED drivers (EZ1). NPS80EZER nLight® dimming pack controls 0-10V eldoLED drivers (EZ1). ER controls fixtures on emergency circuit. N80 nLight™ Lumen Compensation NLTAIR2 nLight® Air enabled NLTAIRER2 nLight® AIR Dimming Pack Wireless Controls. Controls fixtures on emergency circuit, not available with battery pack options NLTAIREM2 nLight® AIR Dimming Pack Wireless Controls. UL924 Emergency Operation, via power interrupt detection. Available with battery pack options. ‡ Option Value Ordering Restrictions Restriction Marked Spacing for 8000 lumens and above. Not available with finishes. 347V is 3' x 3' x 6" overhead marked spacing. 347V only available with EZ1 driver options. Supplied with step-down transformer. Not available with emergency options. Voltage-specific 120, 277V. Only available with AR finish. specify voltage. ER for use with generator supply EM power. Will require an emergency hot feed and normal hot feed. See UL 924 Sequence of Operation table. Fixture begins at 80% light level. Must be specified with NPS80EZ or NPS80EZ ER. Only available with EZ1 drivers. Not available with CP, NPS80EZ, NPS80EZER, NPP16D, NPP16DER or N80 options. Not recommended for metal ceiling installations. Refer to RRL specification sheet on acuitybrands.com for further details. Commercial fixtures should disconnect the TSPL before unplugging the RRL so it does not go into discharge mode. RRLC12S option is to be used with the OnePass OCU, OCS, OD, OFC and OD for 0-24V integrated single-circuit or 0-10V low voltage controls applications. Not available with integral dimming sensors. RALTBD for pricing only. Replace with applicable RAL number and finish when ready to order. See the RAL BROCHURE for available color options. CPC options for pricing only. Custom color chip needs to be sent in to your Customer Resolution specialist before order can be processed. Click HERE for more details Accessories: Order as separate catalog number. EAC ISSM 375 EAC ISSM 125 GRA810 JZ SCA8 Compact interruptible emergency AC power system Compact interruptible emergency AC power system Oversized trim ring with 10" outside diameter Sloped Ceiling Adapter. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA8 10D. LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 Emergency Battery Pack Options - Field Installable Battery Model Number ILB CP07 2H A ILB CP10 A ILBLP CP10 HE SD A+ ILBLP CP15 HE SD A+ ILB CP20 HE A ILB CP20 HE SD A ILBHI CP10 HE SD A+ ILBHI CP15 HE SD A+ Wattage 7W 10W 10W 15W 20W 20W 10W 15W Runtime (Minutes) 120 90 90 90 90 90 90 90 Lumen Output* @ 120 Lumens/Watt 840 1200 1200 1800 2400 2400 1200 1800 Other Storm Shelter / 2 Hour Runtime Title 20, Self Diagnostic Title 20, Self Diagnostic Title 20 Title 20, Self Diagnostic 347-480V AC Input, Title 20, Self Diagnostic 347-480V AC Input, Title 20, Self Diagnostic All the above are UL Listed products that are certified for field install external/remote to the fixture. *Minimum delivered lumen output to assist in product selection for increased fixture mounting height. The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast. Please contact us at techsupport@iotaengineering.com for any Emergency Battery related questions. LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 PHOTOMETRY Distribution Curve Distribution Data Output Data Illuminance Data at 30" Above Floor for a Single Luminaire LDN8 35/120 LO8AR LS, INPUT WATTS: 148.6, DELIVERED LUMENS: 12506.4, LM/W = 84.16, TEST NO. ISF 30850P28 RCR CP Summary 0° 90 ° 12639 12639 2500 ° 12358 12418 5° 11223 11444 8999 5° 8788 5000 4731 5° 4493 1393 5° 1298 7500 25 25 5° 6 100006 5° 2 2 5° 1 0 5° 125000° 0 0 0 Coefficients of Utilization Coefficients of Utilization pf 20% pf 20% 90° pc 80% 70% CP Summary 50% pc 80% 50% Zonal Lumen 70% Summary pw 70%50%30% 50%30%10% pwZone 70%50%30% 50%30%10% Lumens % Lamp %50%30%10% Fixture 80° 0°50%30%10% 90 0 119 119 119 116 116 0 116 111 111 111 119 119 119 116 116 116 111 111 111 67.3 67.3 8413 0° 30° 0° 12639 12639 1 113 111 108 108 106 104 103 101 10°113 90.7103 101 90.7104 104 11338108 106 - 40°111 108 12418 12358 5° 104 2 108 103 99 101 97 98 11444 95 92 20°108 98 95 92 99.994 99.9 12496101 97 - 60°103 99 15° 9411223 60° 3 102 96 90 94 90 90 86 100.0 92 88 84 1250694 100.0 - 90°96 90 899984 30°102 25° 86878892 88 4 97 89 83 88 83 89 830 88 83 86 0.0 81 78 0.0 79 - 180° 473178 490°97 35° 79449386 81 5 92 83 77 82 77 83 77 77 72 100.0 80 75 72 1250682 100.0 180° 139372 50° -92 45° 72129880 75 6 87 78 72 77 71 77 71 67 75 70 67 55° 67 25 75 7025 67 6 87 78 72 7 82 73 67 72 66 72 66 62 71 66 62 65° 62 6 71 666 62 7 82 73 67 40° 8 78 68 62 68 62 68 62 58 67 61 58 75° 58 2 67 612 58 8 78 68 62 9 74 64 58 64 58 64 58 54 63 58 54 85° 54 0 63 581 54 9 74 64 58 10 20° 71 61 55 60 55 60 55 51 59 54 51 90 51 0 59 540 51 10 71 61 55 0° 90° RCR 180° Zonal Lumen Summary Zone Lumens % Lamp % Fixture 67.3 67.3 8413 0° - 30° 90.7 90.7 11338 0° - 40° 99.9 99.9 12496 0° - 60° 100.0 100.0 12506 0° - 90° 0.0 0.0 0 90° - 180° 100.0 100.0 0° - 180° 12506 LDN8 35/150 LO8AR LS, INPUT WATTS: 184.5, DELIVERED LUMENS: 16024.4, LM/W = 86.85, TEST NO. ISF 30850P25 RCR CP Summary 0° 90 ° 16194 16194 3200 ° 15834 15911 5° 14381 14663 5° 11260 6400 11530 5° 5757 6062 5° 1663 9600 1785 5° 32 32 5° 8 128008 5° 3 3 5° 0 1 160000° 0 0 0 Coefficients of Utilization Coefficients of Utilization pf 20% pf 20% 90° pc 80% 70% CP Summary 50% pc 80% 50% Zonal Lumen 70% Summary pw 70%50%30% 50%30%10% 50%30%10% pw 70%50%30% 50%30%10% Zone Lumens % Lamp %50%30%10% Fixture 80° 0° 90 111 111 111 111 111 111 116 116 116 116 119 119 0 119 119 119 116 116 0 119 67.3 67.3 10779 0° 30° 0° 16194 16194 101 10°113 104 103 1 113 111 108 108 106 90.7103 101 90.7104 104 14527108 106 - 40°111 108 5° 104 15834 15911 95 92 20°108 98 14663 98 95 92 2 108 103 99 101 97 99.994 99.9 16012101 97 - 60°103 99 15° 9414381 60° 88 84 30°102 92 11530 92 88 84 90 86 100.0 94 90 3 102 96 90 1602494 100.0 - 90°96 90 25° 8611260 86 88 83 89 830 88 83 4 97 89 83 0.0 81 78 0.0 79 - 180° 35° 79575786 81 606278 490°97 80 75 72 77 72 100.0 82 77 83 77 5 92 83 77 1602482 100.0 180° 45° 72166380 75 178572 50° -92 75 70 67 77 71 77 71 67 6 87 78 72 55° 67 32 75 7032 67 6 87 78 72 71 66 62 72 66 72 66 62 7 82 73 67 65° 62 8 71 668 62 7 82 73 67 40° 67 61 58 68 62 68 62 58 8 78 68 62 75° 58 3 67 613 58 8 78 68 62 63 58 54 64 58 64 58 54 9 74 64 58 85° 54 0 63 581 54 9 74 64 58 20° 59 54 51 60 55 60 55 51 10 71 61 55 90 51 0 59 540 51 10 71 61 55 0° 90° RCR 180° Zonal Lumen Summary Zone Lumens % Lamp % Fixture 67.3 67.3 10779 0° - 30° 90.7 90.7 14527 0° - 40° 99.9 99.9 16012 0° - 60° 100.0 100.0 16024 0° - 90° 0.0 0.0 0 90° - 180° 100.0 100.0 0° - 180° 16024 LDN8 35/200 LO8AR LS, INPUT WATTS: 265.4, DELIVERED LUMENS: 20707.9, LM/W = 78.02, TEST NO. ISF 30850P22. RCR CP Summary 0° 90 ° 20927 20927 4100 ° 20462 20561 5° 18584 18949 5° 14551 8200 14900 5° 7440 7834 5° 2149 12300 2307 5° 42 42 5° 10 16400 10 5° 3 3 5° 0 205002 0° 0 0 0 Coefficients of Utilization Coefficients of Utilization pf 20% pf 20% 90° pc 80% 70% CP Summary 50% pc 80% 50% Zonal Lumen 70% Summary pw 70%50%30% 50%30%10% pwZone 70%50%30% 50%30%10% Lumens % Lamp %50%30%10% Fixture 80° 0°50%30%10% 90 111 00°119 111 111 0 119 119 119 116 116 67.3111 111 67.3116 111 13930116 116 - 30°119 119 0° 116 20927 20927 101 10°113 104 103 1 113 111 108 108 106 90.7103 101 90.7104 104 18773108 106 - 40°111 108 5° 104 20462 20561 92 95 98 98 95 92 94 94 97 101 99 103 2 108 103 99 101 97 2 108 99.9 99.9 20691 0° 60° 15° 18584 18949 60° 88 84 30°102 92 14900 92 88 84 90 86 100.0 94 90 3 102 96 90 2070894 100.0 - 90°96 90 25° 8614551 86 88 83 89 830 88 83 4 97 89 83 0.0 81 78 0.0 79 - 180° 35° 79744086 81 783478 490°97 80 75 72 77 72 100.0 82 77 83 77 5 92 83 77 2070882 100.0 180° 45° 72214980 75 230772 50° -92 75 70 67 77 71 77 71 67 6 87 78 72 55° 67 42 75 7042 67 6 87 78 72 71 66 62 72 66 72 66 62 7 82 73 67 65° 62 10 71 6610 62 7 82 73 67 67 61 58 68 62 68 62 58 8 78 68 62 40° 75° 58 3 67 613 58 8 78 68 62 63 58 54 64 58 64 58 54 9 74 64 58 85° 54 0 63 582 54 9 74 64 58 59 54 51 60 55 60 55 51 71 61 55 10 20° 90 51 0 59 540 51 10 71 61 55 0° 90° RCR 180° HOW TO ESTIMATE DELIVERED LUMENS IN EMERGENCY MODE Use the formula below to estimate the delivered lumens in emergency mode Delivered Lumens = 1.25 x P x LPW P = Ouput power of emergency driver. P = 10W for PS1055CP LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. The LPW rating is also available at Designlight Consortium. Notes • Tested in accordance with IESNA LM-79-08. Zonal Lumen Summary Zone Lumens % Lamp % Fixture 67.3 67.3 13930 0° - 30° 90.7 90.7 18773 0° - 40° 99.9 99.9 20691 0° - 60° 100.0 100.0 20708 0° - 90° 0.0 0.0 0 90° - 180° 100.0 100.0 0° - 180° 20708 LUMEN OUTPUT MULTIPLIERS - FINISH Specular (LS) 1.0 80 1.0 Semi-specular (LSS) 0.95 90 0.874 Matte diffuse (LD) 0.85 White 0.87 Black 0.73 LUMEN OUTPUT MULTIPLIERS - CCT • Tested to current IES and NEMA standards under stabilized laboratory conditions. • CRI: 80 typical. LUMEN OUTPUT MULTIPLIERS - CRI 80CRI 2700K 3000K 3500K 4000K 0.950 0.966 1.000 1.101 LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 *All dimensions in inches (centimeters) unless otherwise noted. 5000lm-6000lm below 157 [40.4] 8 11 [42.4] 1616 13 81 4 [20.9] 816 [22.3] Aperture: 8 58 (21.9) Ceiling Opening: 8 43 (22.2) 8000lm-12,000lm below 157 [40.4] 8 171 4 [43.8] 12 [30.4] 12 9 [31.9] 16 Aperture: 8 58 (21.9) Ceiling Opening: 8 43 (22.2) 15,000lm-20,000lm below 12 [30.5] 12 9 [31.9] 16 157 [40.4] 8 171 4 [43.8] Aperture: 8 58 (21.9) Ceiling Opening: 8 43 (22.2) L 36"x W 36"x H18" marked spacing LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 ADDITIONAL DATA COMPATIBLE 0-10V AND LINE VOLTAGE DIMMERS MANUFACTURER PART NO. CONTOL DEVICE DIM CURVE Synergy® ISD 400 ELV 120 Logarithmic ISD 600 I 120 Logarithmic ISD 1000 I 120 Logarithmic IllumaTech-IPE04 Logarithmic IllumaTech-IPI06 Logarithmic IllumaTech-IPI10 Logarithmic IllumaTech- IPL06-10 Logarithmic Sureslide 6633-P 600-watt 3-way Linear Sureslide 6674-P 600-watt single pole Linear Sureslide 6674-P 600-watt 3-way Linear Leviton® LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 EXAMPLE Group Fixture Control* *Appiication diagram applies for fixtures with eldoLED drivers only. nPS 80 EZ Dimming/Control Pack (qty: 2 required) nPODM 2P DX Dual On/Off/Dim Push-Button WallPod nCM ADCX Daylight Sensor with Automatic Dimming Control nCM PDT 9 Dual Technology Occupancy Sensor nPODM 2P DX nCM PDT 9 Description: This design provides a dual on/off/dim wall station that enables manual control of the fixtures in Row A and Row B separately. Additionally, a daylight harvesting sensor is provided so the lights in Row B can be configured to dim automatically when daylight is available. An occupancy sensor turns off all lights when the space is vacant. A A B C nPS 80 EZ A B B C nPS 80 EZ WIRING KEY A B C CAT-5e Cable Line Power Low Voltage Dimming Wires Choose Wall Controls nLight offers multiple styles of wall controls - each with varying features and user experience. Push-Button Wallpod Traditional tactile buttons and LED user feedback A OPTIONAL nCM ADCX nLight® Wired Controls Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight for complete listing of nLight controls. WallPod Stations Model number Occupancy sensors Model Number On/Off nPODM (Color) Small motion 360º, ceiling (PIR/dual Tech) nCM 9 / nCM PDT 9 On/Off & Raise/Lower nPOD DX (Color) Large motion 360º, ceiling (PIR/dual tech) nCM 10 / nCM PDT 10 Graphic Touchscreen nPOD GFX (Color) Wide View (PIR/dual tech) nWV 16 / nWV PDT 16 Photocell controls Model Number Wall Switch w/ Raise/Lower (PIR/dual tech) nWSX LV DX / nWSX PDT LV DX Dimming nCM ADCX Cat-5 cables (plenum rated) Model Number 10', CAT5 10FT CAT5 10FT J1 15, CAT5 15FT CAT5 15FT J1 Graphic Wallpod Full color touch screen provides a sophisticated look and feel LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23 LDN8 UL924 Sequence of Operation The below information applies to all nLight AIR devices with an EM option. nLight® AIR Control Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlightair. Wall switches On/Off single pole On/Off two pole On/Off & raise/lower single pole On/Off & raise/lower two pole On/Off & raise/lower single pole • EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. • Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. • Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing. Model number rPODB [color] rPODB 2P [color] rPODB DX [color] rPODB 2P DX [color] rPODBZ DX WH1 Notes 1 Can only be ordered with the RES7Z zone control sensor version. nLight AIR nLight AIR is the ideal solution for retrofit or new construction spaces where adding communication is cost prohibitive. The integrated nLight AIR rPP20 Power Pack is part of each Lithonia LDN Luminaire. These individually addressable controls offer the ultimate in flexibility during initial setup and for space repurposing. Simple as 1,2,3 1. Install the nLight® AIR fixtures with embedded smart sensor 2. Install the wireless battery-powered wall switch 3. With CLAIRITY app, pair the fixtures with the wall switch and if desired, customize the sensor settings for the desired outcome nLight AIR rPODB 2P DX Mobile Device LDN8 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.705.SERV(7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/21/23