Annexure-VI. ON-OFF VALVE DATASHEET (TS:7130-ENG-PP1-00000-IPC-TSP-9111 ) TECHNICAL DATA SHEET ON-OFF VALVES WITH PNEUMATIC ACTUATOR S. NO A A.1 A.2 A.3 A.4 A.5 A.6 A.7 A.8 A.9 A.10 A.11 B B.1 B.2 B.3 C C.1 C.2 C.3 C.4 C.5 C.6 C.7 C.8 C.9 C.10 C.11 C.12 C.13 C.14 C.15 PARAMETERS GENERAL Tag Number Service Location P&ID Line Number Operating temperature Operating Pressure Flow range Site Condition Area classification PROCESS & DESIGN PARAMETERS PURCHASE Make Model No. Quantity ON-OFF VALVE Valve Size End Connection Rating Flange Face Finish Body Material Bonnet Type & Material Gland Packing Type & Material Trim type Trim material Stem Material Seat material Plug material Leakage Class D D.1 D.2 D.3 D.4 D.5 D.6 D.7 D.8 D.9 D.10 Stroking time D.11 Time to open/ Time to close C.17 ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII ANNEXURE-VII Refer Annexure-I ANNEXURE-VII ANNEXURE-VII As per preferred make list VTS ANNEXURE-VII ANNEXURE-VII Refer Annexure-VIII (PMS) Refer Annexure-VIII (PMS) Refer Annexure-VIII (PMS) Refer Annexure-VIII (PMS) Refer Annexure-VIII (PMS) Standard & PTFE As per Technical Specification_Clause 4.6 Refer Annexure-VIII (PMS) 17-4PH PTFE reinforced SS 316 ANNEXURE-VII Cv Calculated VTS Max. Flow/ Nor. Flow/Min. Flow Cv Selected % Opening at Max. Flow /Nor. Flow/ Min. Flow Predicted Sound Level dBA Max/Nor. Flow ACTUATOR Actuator make Actuator model no. Type MOC Diaphragm MOC Action Repeatibility Hysteresis effect Stalled torque rating C.16 REQUIREMENT VTS VTS Less than 85 dBA As per preferred make list VTS Pneumatic type VTS VTS (based on service condition) ANNEXURE-VII min. 0.5% of full travel max. +/- 1% of full scale travel 150% of max. required torque for Driven element Not be more than 2 seconds under no-load conditions Upto 15 sec (Failsafe) Page 1 of 3 OFFERED BY VENDOR REMARKS Annexure-VI. ON-OFF VALVE DATASHEET (TS:7130-ENG-PP1-00000-IPC-TSP-9111 ) TECHNICAL DATA SHEET ON-OFF VALVES WITH PNEUMATIC ACTUATOR S. NO PARAMETERS REQUIREMENT D.12 Paint Shade As per Technical Specification_Clause 4.1.3 D.13 D.14 Handwheel Max. allowable Pressure Refer Annexure-VIII (PMS) VTS D.15 Min. air requirement for Actuator VTS D.16 D.17 Air supply Pressure Required Air Failure Position D.18 Enclosure Protection E E.1 E.2 E.3 E.4 E.5 E.6 E.7 E.8 SOLENOID VALVE Solenoid valve Make Model No. Power Supply Coil supply Body Material Coil Insulation for Solenoid Cable Entry E.9 Enclosure Protection E.10 F F.1 F.2 F.3 F.4 F.5 F.6 LED indication PROXIMITY SWITCH Proximity switches Type Make Model No. Contact Rating Power Supply F.7 Enclosure Protection F.8 G G.1 G.2 G.3 G.4 G.5 G.6 H H.1 H.2 H.3 H.4 H.5 I I.1 I.2 I.3 I.4 I.5 I.6 LED indication A/F REEGULATOR Air Set of 1/2" NPT with Gauge Inlet Pressure Max. in AFR Outlet Pressure Filter Element Size Make ACCESSORIES Tube Fittings Adjustable Stop Mechanism Air lock relay/Volume Booster Air Tank Electrical Connection TEST & CERTIFICATES Material Certificate Ex Protection Certificate Shell test Enclosure Certificate Seat leakage test Routine calibration Test (VTS) Kg/cm2(G) ANNEXURE-VII IP 66 (for Safe Area) IS for HAZOURDS Area Required As per preferred make list VTS VTS 24V DC Aluminium Die ‐ Cast Class-'F' ½" NPT Thread IP 66 (for Safe Area) IS for HAZOURDS Area Yes required Open & Close proximity switches 2 wire - Flush Type As per preferred make list VTS 24V DC VTS IP 66 (for Safe Area) IS for HAZOURDS Area Yes required Required with AFR VTS VTS (Adjustable for air supply pressure and flow) Sintered bronze/Glass ½” NPT(F) Norgren As per requirement Max 5 Degree acceptable VTS VTS 1/2" NPT Yes Yes (wherever applicable) Yes Yes Yes Yes Page 2 of 3 OFFERED BY VENDOR REMARKS Annexure-VI. ON-OFF VALVE DATASHEET (TS:7130-ENG-PP1-00000-IPC-TSP-9111 ) TECHNICAL DATA SHEET ON-OFF VALVES WITH PNEUMATIC ACTUATOR S. NO PARAMETERS I.7 Radiography I.8 Documentation I.9 VTS REQUIREMENT Yes Certificates, General Arrangement Drawing, QAP, Catalogues etc. to be submitted. Vendor to Specify Page 3 of 3 OFFERED BY VENDOR REMARKS