PT. FAST TECHNICAL SERVICES INDONESIA Residual Life Assessment Certificate No. 260/RLA/7/02/FTSI-MEDCO/II/2023 PT Fast Technical Services Indonesia sebagai Lembaga Enjiniring sesuai ketentuan Peraturan Menteri Energi dan Sumber Daya Mineral Nomor 32 tahun 2021 telah melakukan Residual Life Assessment (RLA) terhadap : GAS GATHERING STATION Pemilik / Pengguna Instalasi Kapasitas Desain Tekanan Desain Tekanan Operasi Tahun dibuat/digunakan Lokasi Koordinat Fungsi : MEDCO E&P GRISSIK LTD. : Installation Grissik Central Gas Plant (CGP) : Gas 530 MMSCFD dan Condensate 2000 BCPD : 1400 Psig (98,42 Kg/Cm2) : 850 - 1400 Psig (59,76 – 98,42 Kg/Cm2) : 1996 / 1998 : Grissik, Sumatera Selatan : -2.28989, 103.93740 : Pengolahan Gas Bumi Hasil Residual Life Assessment Subject Installation Grissik Central Gas Plant (CGP) RLA 156 Bulan (13 Tahun) dari bulan februari 2023 Daftar Peralatan Utama Storage Tank Pressure Vessel Rotating Pressure Safety valve Electrical Line Piping 1 137 27 150 28 1708 PT Fast Technical Services Indonesia dengan ini menyatakan bahwa Instalasi telah memenuhi ketentuan standar dan kaidah teknis yang berlaku sesuai parameter yang disampaikan (02/RLA/7/INST-01-CGP/FTSI-ME/XII/22) dengan penilaian resiko tertinggi “Medium High”. MEDCO E&P GRISSIK LTD. bertanggung jawab sepenuhnya atas keselamatan instalasi di atas tersebut. Apabila terjadi perubahan desain atau hal – hal yang dapat menyebabkan instalasi tidak layak dan tidak aman untuk dioperasikan maka Sertifikat Penilaian Perpanjangan Sisa Umur Layan ini dapat ditinjau kembali. Surabaya, 22 Februari 2023 PT. FAST TECHNICAL SERVICES INDONESIA (M. ALI MAHFUD.) Director Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY Page 1 of 1 PT. FAST TECHNICAL SERVICES INDONESIA Kesimpulan Hasil RLA Instalasi: 1. Installation dapat dioperasikan sesuai spesifikasi teknis. 2. Instalasi Grissik Central gas Plant (CGP) didesain dengan kapasitas desain 530 MMSCFD dengan tekanan operasi 850 - 1400 Psig (59,76 – 98,42 kg/cm2). 3. Hasil analisis risiko pada instalasi Grissik Central gas Plant (CGP) adalah adalah “medium high”. Risiko tertinggi terdapat pada sistem perpipaan dengan service gas. 4. Dari hasil perhitungan RLA dan analisa pada instalasi Grissik Central Gas Plant (CGP) didapatkan umur sisa adalah 13 tahun (156 bulan). Terdapat pada piping system line no. 4"-FH-20-208-AA2 dan peralatan pressure vessel tag no. 15-V-104. 5. Grissik Central Gas Plant (CGP) dilengkapi dengan peralatan katup pengaman yang telah terinstal dan terverifikasi dengan baik dilapangan. 6. Dalam pengoperasian instalasi Grissik Central Gas Plant (CGP) dijalankan dengan SOP sebagai pedoman atau acuan untuk memastikan kegiatan operasional berjalan dengan lancar dan aman, dengan panduan berupa Prosedur Operasi (ID-N-CG-PR0-PRO-PL-00-0012), Safety Design Philosopy (B-84523-CG-HP1-PHY-PL-00-001) dan Instrument Control System (B-84523-CG-JJ0-PHY-PL-00-0001). 7. Grissik Central Gas Plant (CGP) telah memiliki system fire fighting dan peralatan tambahan yang berada dilapangan berupa APAB, dan APAR, Fire Detector dan Gas Detector sebagai system peringatan dini. Selain memiliki sistem perlindungan kebakaran Grissik Central Gas Plant (CGP) juga memiliki prosedur Emergency response plans (ID-NCG-HH0-ERN-GN-PL-00-0001) sebagai panduan saat terjadi kondisi darurat. Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA Saran / Rekomendasi RLA Instalasi: 1. Melakukan penyusunan terhadap metode dan interval inspeksi pada peralatan, meliputi: Peralatan Putar Metode Inspeksi Interval Inspeksi 1. Pengukuran Getaran 6 Bulan 2. Inspeksi Visual dan Pembersihan 6 Bulan 3. Pengukuran Suhu 6 Bulan 4. Pengukuran Grounding 6 Bulan Referensi Laporan RLA Instalasi Grissik Central Gas Plant (CGP) No. 02/RLA/7/INST-01-CGP/FTSIME/XII/22 Tangki Metode Inspeksi - Visual Inspection & UT Inspection Interval Inspeksi Referensi 48 Bulan API 653 Interval Inspeksi Referensi 48 Bulan API 510 Interval Inspeksi Referensi 48 Bulan Laporan RLA Instalasi Grissik Central Gas Plant Bejana Tekan Metode Inspeksi - Visual Inspection & UT Inspection Sistem Perpipaan Metode Inspeksi - Visual Inspection & UT Inspection (CGP) No. 02/RLA/7/INST-01-CGP/FTSIME/XII/22 Katup Pengaman Metode Inspeksi Interval Inspeksi Referensi - Inspeksi Visual terhadap katup pengaman 12 Bulan API 576 - Pop Test atau Bench Test 48 Bulan API 576 Interval Inspeksi Referensi - Inspeksi visual dan Pembersihan 6 Bulan Laporan RLA Instalasi Grissik Central Gas Plant - Pengukuran Suhu 6 Bulan Peralatan Listrik Metode Inspeksi (CGP) No. 02/RLA/7/INST-01-CGP/FTSI- Office ME/XII/22 PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA 2. Berdasarkan kesimpulan hasil RLA terhadap peralatan yang memiliki sisa umur layan 13 tahun, maka direkomendasikan pada peralatan tersebut yaitu: a. Pada peralatan GL Inlet Separator dengan Tag no. 15-V-104: - Perlu dilakukan inspeksi secara periodik terhadap kondisi visual, korosi dan ketebalan pelat serta memastikan kondisi peralatan masih sesuai dengan inspection code dan requirement thickness yang dibutuhkan untuk tekanan layan. - Perlu dilakukan pemeriksaan ulang peralatan bejana tekan dengan jangka waktu tidak lebih dari 4 tahun, serta rekaman wajib didokumentasikan dengan baik guna untuk mengetahui laju pertumbuhan corrosion. - Untuk perlindungan jangka panjang perlu dilakukan monitoring dan maintenance terhadap kondisi painting/coating bejana tekan. b. Pada Piping System dengan Line no. 4”-FH-20-208-AA2: - Perlu dilakukan inspeksi secara periodik terhadap kondisi visual, korosi dan ketebalan pipa serta memastikan kondisi sistem perpipaan masih sesuai dengan inspection code dan requirement thickness yang dibutuhkan untuk tekanan layan. - Perlu dilakukan pemeriksaan ulang sistem perpipaan dengan jangka waktu tidak lebih dari 4 tahun, serta rekaman wajib didokumentasikan dengan baik guna untuk mengetahui laju pertumbuhan corrosion. - Untuk perlindungan jangka panjang perlu dilakukan monitoring dan maintenance terhadap kondisi painting/coating pada sistem perpipaan. 3. Untuk peralatan lainnya seperti; tangki, peralatan listrik dan katup pengaman, terdapat beberapa hal yang perlu dilakukan saat inspeksi peralatan pada periode inspeksi selanjutnya, adalah: - Peralatan Tangki dengan umur terendah yaitu pada 35-T-102 (Condensate Storage Tank) perlu dilakukan monitoring terhadap kondisi visual, korosi dan ketebalan pelat pada peralatan tersebut. - Peralatan Listrik dengan umur terendah yaitu pada 47-PMC2-04 (MCC) dan 47-PSW2-02 (Switchgear) perlu dilakukan monitoring terhadap kondisi visual pada peralatan tersebut. - Melanjutkan inspeksi dan pemeliharaan pada katup pengaman yaitu inspeksi visual, Pop Test atau Bench Test. 4. Lakukan verifikasi terhadap peralatan yang disertifikasi sebelum masa berlaku sertifikat peralatan berakhir, diantaranya: - Melakukan pengkajian dan verifikasi kesesuaian spesifikasi peralatan dengan dokumen teknis. - Pengambilan data aktual peralatan untuk proses sertifikasi, meliputi data ketebalan pelat, dimensional dan dokumentasi kondisi aktual peralatan. - Melakukan perbandingan kesesuain teknis pada peralatan dengan standar/regulasi dan spesifikasi pemilik. - Melakukan evaluasi dan analisis kelayakan pada peralatan sesuai standard/regulasi dan spesifikasi pemilik. 5. Melakukan perawatan pada instalasi kelistrikan, seperti Panel, Lightning Protection, dan peralatan electronic untuk menghindari kegagalan instalasi yang disebabkan oleh hubungan arus pendek. 6. Memastikan coating pada sistem perpipaan dalam kondisi baik serta melakukan recoating apabila coating dalam kondisi kurang baik. 7. Melakukan pengukuran ketebalan (metode UT thickness) pada lokasi yang sama untuk peralatan bejana tekan, tangki, dan piping system saat melakukan inspeksi selanjutnya. 8. Untuk menjaga integritas dan keselamatan instalasi, tekanan operasi pada peralatan/sistem perpipaan tidak boleh melebihi design specification yang telah ditentukan. Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA LAMPIRAN A. Storage Tank No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). Capacity (M3) 1 TANK, CONDENSATE STORAGE 35-T102 1998 0,31 145 858,53 B. Pressure Vessel No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 1 2 FILTER, SUBAN PIPELINE "A" FILTER, SUBAN PIPELINE "B" DRUM, GLT INLET SEPARATOR LIQUID LEVEL SEPARATOR, GLT INLET SEPARATOR, DAYUNG INLET SEPARATOR, SUMPAL INLET STABILIZER, CONDENSATE REBOILER, CONDENSATE STABILIZER DRUM, STABILIZER FEED COOLER, HC CONDENSATE FILTER, POLISHING FILTER, POLISHING EXCHANGER, GAS/GAS HEAT COOLER, GAS EXCHANGER, GAS/GAS HEAT COOLER, GAS FILTER, PRODUCT GAS FILTER, COALESCING FILTER, PRODUCT GAS ADSORBER ADSORBER ADSORBER ADSORBER SEPARATOR, HP GAS ADSORBER ADSORBER ADSORBER ADSORBER SEPARATOR, HP GAS COOLER, TREATED GAS #1 COOLER, TREATED GAS #2 COOLER, TREATED GAS #3 COOLER, TREATED GAS #4 CONTACTOR, AMINE "4" 15-F-101A 15-F-101B 2002 2002 1400 1400 150 150 15-M-101A 2000 1480 120 15-V-104 15-V-105 15-V-107 35-C-101 1997 1997 1997 1997 1150 1250 1250 200 120 120 120 365 35-E-103 1997 200 365 35-V-101 35-E-102 20-V-1703 20-V-1706 21-E-102 21-E-103 21-E-202 21-E-203 21-S-101 21-S-102 21-S-201 21-V-101A 21-V-101B 21-V-101C 21-V-101D 21-V-102 21-V-201A 21-V-201B 21-V-201C 21-V-201D 21-V-202 24-HAL-101 24-HAL-201 24-HAL-301 24-HAL-401 24-MAF-401 1997 2012 1997 1997 1999 1999 1999 1999 1999 1999 1999 1999 1999 1999 1999 1999 1999 2000 2000 2000 1999 2012 2012 2012 2012 2012 320 200 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 86 365 175 175 650 650 650 650 125 350 125 650 650 650 650 350 650 650 650 650 350 200 200 200 200 200 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 35 36 37 38 39 40 41 42 43 FILTER, POLISHING FILTER, POLISHING SEPARATOR, TREATED GAS "4" CONTACTOR, AMINE "1" CONTACTOR, AMINE "2" CONTACTOR, AMINE "3" SEPARATOR, TREATED GAS "1" SEPARATOR, TREATED GAS "2" SEPARATOR, TREATED GAS "3" FILTER, SALES GAS COALESCING "A" FILTER, SALES GAS COALESCING "B" MIXER, STATIC EXCHANGER, GAS/GAS SUBCOOLER, GAS CHILLER&HC CONDENSATE SEPARATOR, LOW TEMPERATURE EXCHANGER, GAS/LEAN GLYCOL TRAIN #4 CONTACTOR, GLYCOL TRAIN#4 CONTACTOR, GLYCOL TRAIN#1 CONTACTOR, GLYCOL TRAIN#2 CONTACTOR, GLYCOL TRAIN#3 DRUM, FLARE KO DEPROPANIZER CONDENSER, DEPROPANIZER OVERHEAD REBOILER, DEPROPANIZER CONDENSER, PROPANE DRUM, DEPROPANIZER OVERHEAD DRUM, PROPANE STORAGE ACCUMULATOR, PROPANE DRUM, PROPANE COMPRESSOR SUCTION DEOILER, REFRIGERANT REGENERATOR, AMINE REGENERATOR, AMINE CONDENSER, REGENERATOR REFLUX REBOILER, REGENERATOR "A" REBOILER, REGENERATOR "B" REBOILER, REGENERATOR "C" REBOILER, REGENERATOR "D" COOLER, LEAN AMINE EXCHANGER, LEAN/RICH AMINE EXCHANGER, LEAN/RICH AMINE 24-MAJ-105 24-MAJ-205 24-MBD-403 25-C-101 25-C-201 25-C-301 25-V-103 25-V-203 25-V-303 2012 2012 2012 1997 1997 1997 1997 1997 1997 1250 1250 1250 1250 1250 1250 1254 1254 1254 175 175 150 200 200 200 150 150 150 42-F-101A 2002 1250 150 42-F-101B 2002 1250 150 42-MX-001 30-E-102 2002 1997 1400 1250 150 150 30-E-103 1997 275 & 1250 121 30-V-101 1997 1250 120 27-HBG-401 2012 1250 450 27-MAF-401 41-C-101 41-C-201 41-C-301 48-V-101 30-C-101 2012 1997 1997 1997 1997 1997 1250 1250 1250 1250 50 300 175 175 175 175 350 430 30-E-104 1997 300 212 3,00E-104 30-E-106 30-V-102 30-V-103 30-V-104 1997 1997 1997 1997 1997 300 275 300 275 275 430 170 150 150 150 30-V-105 1997 275 100 30-V-106 25-C-102 25-C-202 1997 1997 1997 275 90 90 150 300 300 25-E-102 1997 75 250 25-E-102A 25-E-102B 25-E-102C 25-E-102D 25-E-104 25-E-104A 25-E-104B 1997 1997 1997 1997 1997 1997 1997 75 75 75 75 180 151 150 300 300 195 195 250 300 250 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 Office Description CONDENSER, REGENERATOR REFLUX REBOILER, REGENERATOR "A" REBOILER, REGENERATOR "B" REBOILER, REGENERATOR "C" REBOILER, REGENERATOR "D" COOLER, LEAN AMINE EXCHANGER, LEAN/RICH AMINE EXCHANGER, LEAN/RICH AMINE FILTER, AMINE CATRIDGE FILTER, AMINE CHARCOAL FILTER, AMINE CATRIDGE ACCUMULATOR, REGENERATOR REFLUX DRUM, RICH AMINE FLASH POT, REBOILER CONDENSATE "A" POT, REBOILER CONDENSATE "B" POT, REBOILER CONDENSATE "C" POT, REBOILER CONDENSATE "D" POT, MAKE-UP STEAM KO ACCUMULATOR, REGENERATOR REFLUX DRUM, RICH AMINE FLASH POT, REBOILER CONDENSATE "A" POT, REBOILER CONDENSATE "B" POT, REBOILER CONDENSATE "C" POT, REBOILER CONDENSATE "D" POT, MAKE-UP STEAM KO FILTER, POST AMINE CATRIDGE EXCHANGER, LEAN/RICH GLYCOL EXCHANGER, LEAN/RICH GLYCOL EXCHANGER, LEAN/RICH GLYCOL FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CARBON FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CARBON FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CATRIDGE FILTER, GLYCOL CARBON SEPARATOR, RICH GLYCOL FLASH SEPARATOR, RICH GLYCOL FLASH SEPARATOR, RICH GLYCOL FLASH EXCHANGER, LEAN/RICH GLYCOL FILTER, GLYCOL CATRIDGE "A" FILTER, GLYCOL CATRIDGE "B" Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 25-E-202 1997 75 250 25-E-202A 25-E-202B 25-E-202C 25-E-202D 25-E-204 25-E-204A 25-E-204B 25-S-101 25-S-102 25-S-201 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 75 75 & 195 75 & 195 75 & 195 180 149 & 75 149 180 180 200 300 300 & 400 300 & 400 300 & 400 250 250 & 301 250 150 150 150 25-V-101 1997 75 190 25-V-102 25-V-105A 25-V-105B 25-V-105C 25-V-105D 25-V-106 1998 1997 1997 1997 1997 1997 150 195 195 195 195 258 200 400 400 400 400 400 25-V-201 1997 75 190 25-V-202 25-V-205A 25-V-205B 25-V-205C 25-V-205D 25-V-206 46-MAJ-001 41-E-102 41-E-202 41-E-302 41-S-101A 41-S-101B 41-S-102 41-S-201A 41-S-201B 41-S-202 41-S-301A 41-S-301B 41-S-302 41-V-103 41-V-203 41-V-303 47-HBG-401 47-MAJ-401A 47-MAJ-401B 1997 1997 1997 1997 1997 1997 2011 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 1997 2012 2012 2012 150 195 195 195 195 195 262 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 400 400 400 400 400 180 451 451 451 200 200 200 200 200 200 200 200 200 200 200 200 450 200 200 PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 119 120 121 122 123 124 125 126 127 FILTER, GLYCOL CARBON FILTER, GLYCOL FINE SEPARATOR, RICH GLYCOL FLASH CONDENSER, EXCESS STEAM DRUM, CONDENSATE FILTER, FUEL GAS PREHEATER, FUEL GAS DRUM, LP FUEL GAS KO DRUM, HP FUEL GAS KO SCRUBBER, LOW TEMP. FUEL GAS K.O DRUM RECEIVER, INSTRUMENT AIR RECEIVER, INSTRUMENT AIR 47-MAJ-402 47-MAJ-403 47-MBD-403 46-E-102 46-V-105 47-S-101 50-E-103 50-V-101 50-V-102 2012 2012 2012 2015 1997 1997 1997 1997 1997 150 150 150 75 75 270 1310 215 215 200 200 200 345 245 150 400 120 120 60-MBF-002 2020 100 120 21-V-103 51-V-101 1999 1997 150 168 150 180 128 129 130 C. Rotating No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Office Description PUMP, CONDENSATE SHIPPING "A" PUMP, CONDENSATE SHIPPING "B" PUMP, FLARE KO DRUM "A" PUMP, FLARE KO DRUM "B" COMPRESSORE, PROPANE "A" COMPRESSORE, PROPANE "B" COMPRESSORE, PROPANE "C" PUMP, DEPROPANIZER FEED PUMP, DEPROPANIZER REFLUX PUMP, PROPANE TRANSFER PUMP, LEAN AMINE BOOSTER "A" PUMP, LEAN AMINE BOOSTER "B" PUMP, LEAN AMINE BOOSTER "C" PUMP, LEAN AMINE CHARGE "A" PUMP, LEAN AMINE CHARGE "B" PUMP, LEAN AMINE CHARGE "C" PUMP, AMINE SUMP PUMP, AMINE TRANSFER Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). Capacity (M3/H) 35-P102A 1997 1500 98,6 14,3 35-P102B 1997 1500 98,6 14,3 48-P101A 48-P101B 1997 1997 10 10 - 11,35 11,35 30-K101A 1997 312 120 968,4 30-K101B 1997 312 120 968,4 30-K101C 1997 312 120 968,4 30-P101 1997 273 - 5,41 30-P102 2003 280 - 5,41 30-P103 1997 280 - 9 25-P101A 1997 250 223 683,6 25-P101B 1997 250 223 683,6 25-P101C 1997 250 223 683,6 25-P102A 1997 2150 120 568 25-P102B 1997 2150 120 568 25-P102C 1997 2150 120 568 25-P104 25-P105 1997 1997 85 38 60 60 9,1 9,1 PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). Capacity (M3/H) 19 PUMP, GLYCOL TRANSFER PUMP, GLYCOL CIRCULATION "A" PUMP, GLYCOL CIRCULATION "B" PUMP, GLYCOL CIRCULATION "A" PUMP, GLYCOL CIRCULATION "B" PUMP, GLYCOL CIRCULATION "A" PUMP, GLYCOL CIRCULATION "B" PUMP, FIRE WATER JOCKEY PUMP, ELECTRIC FIRE WATER PUMP, DIESEL FIRE WATER 41-P101 1997 150 - - 41-P102A 1997 1991 222 6,72 41-P102B 1997 1991 222 6,72 41-P202A 1997 1991 222 6,72 41-P202B 1997 1991 222 6,72 41-P302A 1997 1991 222 6,72 41-P302B 1997 1991 222 6,72 55-P301A 1997 120 - 11,35 55-P302A 1997 150 - 22,7 55-P302B 1997 150 - 22,7 20 21 22 23 24 25 26 27 28 D. Pressure Safety Valve No 1 2 3 4 5 Description VALVE, PRESS.SAFETY FROM GLT SLUG CATCHER VALVE, PRESS.SAFETY FROM GLT SLUG CATCHER VALVE, PRESSURE SAFETY OF 15V104 VALVE, PRESS.SAFETY OF 15V107 VALVE, PRESS.SAFETY OF 15V107 Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 15-PSV-004A 1998 1140 97 15-PSV-004B 1998 1310 100 15-PSV-007 1998 1250 84 15-PSV-10A 1998 1310 125 15-PSV-10B 1998 1310 125 6 VALVE, PRESSURE SAFETY OUTLET 15F101A_B 15-PSV-10C 1998 1310 188 7 VALVE, PRESSURE SAFETY OF 15F101C 15-PSV-2071 2006 1400 150 8 VALVE, PRESSURE SAFETY OF 15F101A 15-PSV-401 2002 1400 151 9 VALVE, PRESSURE SAFETY OF 15F101B 15-PSV-402 2002 1200 150 10 VALVE, PRESSURE SAFETY OUTLET 15F101A_B 15-PSV-403 1998 1372 151 11 VALVE, PRESSURE SAFETY OUTLET 15F101A_B 15-PSV-404 2002 1400 140 Office Protected Equipment GLT INLET SEPARATOR INLET SEPARATOR GLT INLET SEPARATOR INLET SEPARATOR INLET SEPARATOR PIPELINE FILTER DISCHARGE SUBAN PIPELINE FILTER SUBAN PIPELINE FILTER SUBAN PIPELINE FILTER PIPELINE FILTER DISCHARGE PIPELINE FILTER DISCHARGE PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description VALVE, PRESS.SAFETY OF 15V107 VALVE, PRESSURE SAFETY OF 15V105 VALVE, PRESSURE SAFETY OF 15V105 VALVE, PRESSURE SAFETY OF 15V105 VALVE, PRESSURE SAFETY OF 35V101 VALVE, PRESSURE SAFETY OF 35C101 VALVE, PRESSURE SAFETY OF 35S101 VALVE, PRESSURE SAFETY VACUUM ON 35T102 VALVE, PRESSURE SAFETY OF 20V1703 VALVE, PRESSURE SAFETY OUTLET 20A102A_B VALVE, PRESSURE SAFETY PRESSURE 20V17.05 VALVE, PRESSURE SAFETY OUTLET 20A102C_D VALVE, PRESSURE SAFETY OF 21V101A VALVE, PRESSURE SAFETY OF 21V101B VALVE, PRESSURE SAFETY OF 21V101C VALVE, PRESSURE SAFETY OF 21V101D VALVE, PRESSURE SAFETY OF 21S101 VALVE, PRESSURE SAFETY OF 21V102 VALVE, PRESSURE SAFETY OF 21S102 VALVE, PRESS. SFTY. COOLING GAS FR. ADSORBER Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 15-PSV-405 1998 1310 150 20-PSV-005A 2013 1250 90 20-PSV-005B 2013 1280 90 20-PSV-005C 2013 1310 90 35-PSV-001 1998 320 42 35-PSV-002 1998 200 31 35-PSV-101 2019 675 100 35-PVSV-006 2018 0,31 100 20-PSV-101 1998 1250 246 20-PSV-105 2006 260 175 20-PSV-201 2018 1250 95 20-PSV-205 2006 260 175 21-PSV-104 2000 1250 250 FEED GAS INLET 21-PSV-105 2000 1250 350 FEED GAS INLET 21-PSV-106 2000 1250 351 FEED GAS INLET 21-PSV-107 2000 1250 130 FEED GAS INLET 21-PSV-108 2000 1250 351 21-PSV-109 2000 1250 351 21-PSV-110 2000 1250 150 21-PSV-111 2016 1250 250 Protected Equipment INLET SEPARATOR INLET SEPARATOR INLET SEPARATOR INLET SEPARATOR STABILLIZED FEED DRUM CONDENSATE STABILLIZER CONDENSATE METERING PACKAGE CONDENSATE TANK INLET SEPARATOR PIPE FROM MEMBRANE FOLISHING FILTER MEMBRANE PACKAGE PRODUCT GAS FILTER HP GAS SEPARATOR COALESCLING FILTER REGENERATOR GAS HEATER THERMAL SWING ADSORBER THERMAL SWING ADSORBER THERMAL SWING ADSORBER 32 VALVE, PRESSURE SAFETY OF 21V201A 21-PSV-204 2000 1250 350 33 VALVE, PRESSURE SAFETY OF 21V201B 21-PSV-205 2000 1250 350 34 VALVE, PRESSURE SAFETY OF 21V201C 21-PSV-206 2000 1250 350 21-PSV-207 2000 1250 350 ADSORBER 21-PSV-208 2000 1250 90 PRODUCT GAS FILTER 35 36 VALVE, PRESSURE SAFETY OF 21V201D VALVE, PRESSURE SAFETY OF 21S201 Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No 37 38 39 40 41 42 Description VALVE, PRESSURE SAFETY OF 21V202 VALVE, PRESS. SFTY. COOLING GAS FR. ADSORBER VALVE, PRESSURE SAFETY OF 24SBA102E_F VALVE, PRESS. SAFETY OUTLET 24SBA102G_H VALVE, PRESS. SAFETY OF 24MBD403 VALVE, PRESSURE SAFETY OF 24MAJ105 Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 21-PSV-209 2000 1250 351 21-PSV-211 2017 1250 350 24-PSV-0122 2013 260 104 24-PSV-0222 2013 260 104 24-PSV-0401 2013 1250 134 24-PSV-1008 2013 1250 122 43 VALVE, PRESS.SAFETY OUTLET 24CAE101 24-PSV-1106 2013 1250 105 44 VALVE, PRESSURE SAFETY OF 24MAJ205 24-PSV-2008 2013 1250 122 45 VALVE, PRESS. SAFETY OUTLET 24CAE201 24-PSV-2106 2017 1250 105 25-PSV-100 1998 1250 118 25-PSV-200 1998 1250 250 25-PSV-300 2013 1250 120 46 47 48 VALVE, PRESSURE SAFETY OF 25V103 VALVE, PRESSURE SAFETY OF 25V203 VALVE, PRESSURE SAFETY OF 25V303 49 VALVE, PRESSURE SAFETY OF 42F101A 42-PSV-407 2002 1250 190 50 VALVE, PRESSURE SAFETY OF 42F101B 42-PSV-408 2002 1250 114 51 VALVE, PRESSURE SAFETY OF 30E102 30-PSV-001 1998 275 120 52 VALVE, PRESSURE SAFETY FROM 30E102 30-PSV-003 1998 1250 18 42-PSV-104_1 2018 100 99 27-PSV-0401 2013 1250 132 41-PSV-201 1998 1250 120 41-PSV-301 1998 1250 134 42-PSV-204_1 2018 100 99 42-PSV-304_1 2018 100 99 30-PSV-002 1998 275 150 53 54 55 56 57 58 59 VALVE, PRESS. SAFETY ATÂ TANK 25MBL001 VALVE, PRESS. SAFETY OUTLET 27MAF401 VALVE, PRESSURE SAFETY OF 41C201 VALVE, PRESSURE SAFETY OF 41C301 VALVE, PRESS. SAFETY OF 42XV204 VALVE, PRESS. SAFETY ATÂ TANK 25MBL002 VALVE, PRESSURE SAFETY OF 30V106 Office Protected Equipment HP GAS SEPARATOR REGENERATOR GAS HEATER MEMBRANE PACKAGE MEMBRANE PACKAGE TREATED GAS SEPARATOR POLISHING FILTER REGEN GAS COMPRESSOR DISCHARGE POLISHING FILTER REGENERATION GAS COMPRESSOR TREATED GAS SEPARATOR TREATED GAS SEPARATOR TREATED GAS SEPARATOR SALES GAS COALESCING FILTERS SALES GAS COALESCING FILTERS GAS CHILLER & HC CONDENSATE SUBCOOLER GAS CHILLER & HC CONDENSATE SUBCOOLER AIR VOLUME TANK GLYCOL CONTRACTOR GLYCOL CONTRACTOR GLYCOL CONTRACTOR AIR VOLUME TANK AIR VOLUME TANK REFIGERANT DE OILER PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 60 VALVE, PRESSURE SAFETY OF 30V104 30-PSV-007 1998 275 150 61 VALVE, PRESSURE SAFETY OF 30V102 30-PSV-008 1998 300 84 30-PSV-009 1998 300 123 30-PSV-010 1998 275 149 30-PSV-012 1998 300 149 30-PSV-101A 1998 275 154 30-PSV-101B 2019 275 156 30-PSV-101C 1998 275 154 25-PSV-001 1998 180 49 62 63 64 65 66 67 68 VALVE, PRESSURE SAFETY OF 30P101 VALVE, PRESSURE SAFETY OF 30V103 VALVE, PRESSURE SAFETY OF 30C101 VALVE, PRESSURE SAFETY OF 30K101AV1 VALVE, PRESSURE SAFETY OF 30K101BV1 VALVE, PRESSURE SAFETY OF 30K101CV1 VALVE, PRESSURE SAFETY OF 25S101 69 VALVE, PRESSURE SAFETY OF 25S201 25-PSV-002 1998 200 49 70 VALVE, PRESSURE SAFETY OF 25S102 25-PSV-003 1998 180 120 71 VALVE, PRESSURE SAFETY OF 25A101P1 25-PSV-005 1998 150 100 72 VALVE, PRESS. SFTY 1"FISHER 95H, REG FAIL 25-PSV100_0229792 2018 50 86 25-PSV-110A 1998 150 169 25-PSV-110B 1998 125 162 25-PSV-110C 1998 125 162 25-PSV-120 1998 150 261 25-PSV-1211 1998 100 99 25-PSV-122 1998 75 217 25-PSV-1221 2018 100 99 25-PSV-210A 1998 125 162 25-PSV-210B 1998 150 169 25-PSV-210C 2018 150 165 25-PSV-220 1998 150 120 25-PSV-221 1998 150 261 73 74 75 76 77 78 79 80 81 82 83 84 VALVE, PRESSURE SAFETY OF 25V102 VALVE, PRESSURE SAFETY OF 25V102 VALVE, PRESSURE SAFETY OF 25V102 VALVE, PRESSURE SAFETY OF 25E104B VALVE, PRESS. SAFETY OF 25FV121 VALVE, PRESSURE SAFETY OF 25C102 VALVE, PRESS. SAFETY OF 25FV122 VALVE, PRESSURE SAFETY OF 25V202 VALVE, PRESSURE SAFETY OF 25V202 VALVE, PRESSURE SAFETY OF 25V202 VALVE, PRESSURE SAFETY OF 25E204B VALVE, PRESSURE SAFETY OF 25E204A Office Protected Equipment PROPANE ACCUMULATOR DEPROPANE OVERHEAD DRUM DEPROPANIZER FEED PUMP PROPANE STORAGE DRUM DEPROPANIZER PROPANE COMPRESSOR COMPRESSOR OIL SEPARATOR PROPANE COMPRESSOR AMINE CATRIDGE AMINE CHARCOLE FILTER AMINE CHARCOLE FILTER ANTI FOAM INJECTION AMINE UNLOADING FACILITY RICH AMINE FLASH DRUM RICH AMINE FLASH DRUM RICH AMINE FLASH DRUM RICH AMINE EXCHANGER AIR VOLUME TANK AMINE REGENERATOR AIR VOLUME TANK RICH AMINE FLASH DRUM RICH AMINE FLASH DRUM RICH AMINE FLASH DRUM RICH AMINE EXCHANGER RICH AMINE EXCHANGER PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No 85 86 87 88 89 90 91 92 93 Description VALVE, PRESS.SAFETY OF 25FV221 VALVE, PRESSURE SAFETY OF 25C202 VALVE, PRESS.SAFETY OF 25FV222 VALVE, PRESS.VACUUM SAFETY OF 25T101 VALVE, PRESS.VACUUM SAFETY OF 25T101 VALVE, PRESSURE SAFETY VACUUM OF 25T102 VALVE, PRESSURE SAFETY VACUUM OF 25Z101 VALVE, PRESSURE SAFETY OF 46MAJ0001 VALVE, PRESSURE SAFETY SPARE GLYCOL Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 25-PSV-2211 2018 100 99 25-PSV-222 2013 75 331 25-PSV-2221 2018 100 99 25-PVSV-001A 2018 1,45 223 25-PVSV-001B 2018 1,45 223 25-PVSV-002 2018 0,3 95 25-PVSV-003 2013 7 200 46-PSV-0001 2011 180 180 41-PSV1_2_3_03_04 1998 150 103 94 VALVE, PRESSURE SAFETY OF 41V103 41-PSV-102 1998 150 176 95 VALVE, PRESSURE SAFETY OF 41S101A 41-PSV-103 1998 150 175 96 VALVE, PRESSURE SAFETY OF 41S101B 41-PSV-104 1998 150 175 97 VALVE, PRESSURE SAFETY OF 41P102A 41-PSV-105 1998 1132 107 98 VALVE, PRESSURE SAFETY OF 41P102B 41-PSV-106 2017 1332 225 99 VALVE, PRESSURE SAFETY OF 41S102 41-PSV-107 2006 100 113 100 VALVE, PRESSURE SAFETY OF 41V203 41-PSV-202 1998 150 175 101 VALVE, PRESSURE SAFETY OF 41S201A 41-PSV-203 1998 150 203 102 VALVE, PRESSURE SAFETY OF 41S201B 41-PSV-204 1998 150 203 103 VALVE, PRESSURE SAFETY OF 41P202A 41-PSV-205 1998 1332 459 104 VALVE, PRESSURE SAFETY OF 41S202 41-PSV-207 1998 150 138 105 VALVE, PRESSURE SAFETY OF 41V303 41-PSV-302 1998 150 175 Office Protected Equipment AIR VOLUME TANK AMINE REGENERATOR AIR VOLUME TANK LEAN AMINE SURGE TANK LEAN AMINE SURGE TANK AMINE SURGE TANK AMINE SUMP TANK AMIN FILTER GLYCOL CATRIDGE RICH GLYCOL FLASH SEPARATOR GLYCOL CATRIDGE FILTER GLYCOL CATRIDGE FILTER GLYCOL CIRCULATION PUMP GLYCOL CIRCULATION PUMP GLYCOL CARBON FILTER RICH GLYCOL FLASH SEPARATOR GLYCOL CATRIDGE FILTER GLYCOL CATRIDGE FILTER GLYCOL CIRCULATION PUMP GLYCOL CARBON FILTER RICH GLYCOL FLASH SEPARATOR PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 106 VALVE, PRESSURE SAFETY OF 41S301A 41-PSV-303 1998 150 203 107 VALVE, PRESSURE SAFETY OF 41P302A 41-PSV-305 1998 1325 225 108 VALVE, PRESSURE SAFETY OF 41P302B 41-PSV-306 1998 1332 225 109 VALVE, PRESSURE SAFETY OF 41S202 41-PSV-307 1998 150 175 110 VALVE, PRESSURE SAFETY OF 47MBD403 47-PSV-0402 2013 150 175 111 VALVE, PRESSURE SAFETY OF 47MAJ401A 47-PSV-0404 2013 150 171 112 VALVE, PRESSURE SAFETY OF 47MAJ401B 47-PSV-0411 2013 150 171 113 VALVE, PRESSURE SAFETY OF 47MAJ402 47-PSV-0412 2013 150 171 114 VALVE, PRESSURE SAFETY OF 47PBA402A 47-PSV-0413 2013 1332 225 115 VALVE, PRESSURE SAFETY OF 47PBA402B 47-PSV-0415 2013 1332 225 46-PVSV-001 - 75 345 DE-AERATOR 53-PSV-151 1998 125 95 ACTIVATED CARBON FILTER 53-PSV-152 1998 125 95 SOFTENER 53-PSV-153 1998 125 95 SOFTENER 46-PSV-003 2019 150 150 47-PSV-007 1998 260 150 50-PSV-001 1997 100 74 50-PSV-002 1998 260 91 50-PSV-003 1998 195 169 21-PSV-112 2000 150 120 51-PSV-001 1998 145 120 51-PSV-101 1997 145 90 116 117 118 119 120 121 122 123 124 125 126 127 VALVE, PRESSURE SAFETY VACUUM OF 46DA101 VALVE, PRESSURE SAFETY OF 53A201V1 VALVE, PRESSURE SAFETY OF 53A201V2A VALVE, PRESSURE SAFETY OF 53A201V2B VALVE, PRESSURE SAFETY OF 46V105 VALVE, PRESSURE SAFETY OF 47S101 VALVE, PRESS. SFTY. FUEL GAS DISTRIBUTION VALVE, PRESSURE SAFETY OF 50V102 VALVE, PRESS. SAFETY FROM STEAM HEADER VALVE, PRESSURE SAFETY OF 21V103 VALVE, PRESSURE SAFETY OF 51V101 VALVE, PRESSURE SAFETY OF 51A101ASRB1 Office Protected Equipment GLYCOL CATRIDGE FILTER GLYCOL CIRCULATION PUMP GLYCOL CIRCULATION PUMP GLYCOL CARBON FILTER RICH GLYCOL FLASH SEPARATOR GLYCOL CATRIDGE FILTER GLYCOL CATRIDGE FILTER GLYCOL CATRIDGE FILTER GLYCOL CIRCULATION PUMP GLYCOL CIRCULATION PUMP CONDENSATE DRUM FUEL GAS FILTER LP FUEL GAS K.O DRUM HP FUEL GAS K.O DRUM FUEL GAS PRE HEATER INSTRUMENT AIR RECEIVER INSTRUMENT AIR RECEIVER AIR COMPRESSOR PACKAGE PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build Des. Pres. (Psig) Des. Temp (°F). 128 VALVE, PRESSURE SAFETY OF 51A101BSRB1 51-PSV-102 1998 145 120 51-PSV-103 1998 150 200 51-PSV-104 1998 150 200 51-PSV-105 1998 150 200 51-PSV-106 1998 150 200 51-PSV-107 1998 145 120 VALVE, PRESSURE SAFETY OF 51A101B VALVE, PRESSURE SAFETY OF 51A101B VALVE, PRESSURE SAFETY OF 51A101AV1A VALVE, PRESSURE SAFETY OF 51A101AV1B VALVE, PRESS. SAFETY OF 51V103A 129 130 131 132 133 134 VALVE, PRESS. SAFETY OF 51V103B 51-PSV-108 1998 145 120 135 VALVE, PRESSURE SAFETY SPARE 51PSV107_108 51-PSV-109 1998 145 120 67-PSV-002 2013 145 132 67-PSV-2005 2001 200 120 VALVE, PRESS.SAFETY OF 67MBF201 VALVE, PRESS. SAFETY OF 67CAE201 136 137 138 VALVE, PRESS. SFTY. OF 67MBK201A 67-PSV-2035 2013 232 120 139 VALVE, PRESS. SFTY. OF 67MBK201B 67-PSV-2036 2013 232 120 140 VALVE, PRESSURE SAFETY OF 55P302A 55-PSV-031 1998 175 85 141 VALVE, PRESSURE SAFETY OF 55P302B 55-PSV-032 2018 175 86 Protected Equipment AIR COMPRESSOR PACKAGE AIR DRYER LEFT CHAMBER AIR DRYER LEFT CHAMBER AIR DRYER LEFT CHAMBER AIR DRYER LEFT CHAMBER AIR DRYER LEFT CHAMBER AIR DRYER RIGHT CHAMBER AIR COMPRESSOR PACKAGE INSTRUMENT AIR RECEIVER STATIONARY COMPRESSOR AIR COMPRESSOR PACKAGE AIR COMPRESSOR PACKAGE ELECTRICAL FIRE WATER PUMP DIESEL ENGINE CONTROL PANEL E. Electrical No Description Tag. No Year Build 1 MCC,"A" 400-231V AT GAS CAMP TRANSFORMER, PWR. 4.16KV400231 500KVA CAMP MCC,400V AT OFFSITE TRANSFORMER, 4.16KV/400-231V AT OFFSITE TRANSFORMER, 4.16KV/400-231V AT OFFSITE 63-PMC2-01A 1998 63-PTR1-01 1998 62-PMC2-01A 1998 62-PTR1-01 1998 62-PTR2-01 1998 6 GENERATOR, OF 47GTG101A 47-G101A 1998 Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur 2 3 4 5 SERVING FOR BETTER QUALITY Specification 480V, 1200A, 60Hz, 3Ph 500kVA, 480V, 721A, 60Hz, 3Ph 480V, 1200A, 60Hz, 3Ph 500kVA, 480V, 721A, 60Hz, 3Ph 300kVA, 480V, 433A, 60Hz, 3Ph 6000kVA, 4160V, 824A, 60Hz, 3Ph LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Description Tag. No Year Build 7 GENERATOR, OF 47GTG101B 47-G101B 1998 8 GENERATOR, OF 47GTG101C 47-G101C 1998 9 10 11 12 13 MCC, 4.16 KV AT MPCR MCC, 4.16 KV AT MPCR MCC, 4.16 KV AT PCR-A MCC, 4.16 KV AT PCR-A SWITCHGEAR, 4.16 KV AT MPCR 47-PMC1-01A 47-PMC1-01B 47-PMC1-02A 47-PMC1-02B 47-PSW1-01A 1998 2003 2013 2003 1998 14 GENERATOR, OF 81SEG103 81-ZEG-103 2013 15 16 17 18 MCC, "A" 480V AT PCR "A" MCC, "B" 480V AT PCR "A" MCC, "C" 480V AT PCR "A" SWITCHGEAR, 480 V AT PCR-A TRANSFORMER, 4.16KV/480V OF 47PSW2_01 TRANSFORMER, 4.16KV/480V OF 47PSW2_01 TRANSFORMER, 4.16KV/480V OF 47PSW2_01 47-PMC2-01A 47-PMC2-01B 47-PMC2-01C 47-PSW2-01 1998 1998 1998 1998 47-PTR1-02A 1997 47-PTR1-02B 2015 81-ZET-003 2019 22 GENERATOR, EMERGENCY DIESEL 47-G102 1998 23 24 25 26 MCC,"UA" 480V AT MPCR MCC,"UB" 480V AT MPCR MCC,"E" 480V AT MPCR SWITCHGEAR, 480 V AT MPCR TRANSFORMER, POWER 2.5 MVA AT MPCR MCC, AUX 480V OF GTG "D" 47-PMC2-02 47-PMC2-03 47-PMC2-04 47-PSW2-02 1998 1998 1998 1998 47-PTR1-01 1997 82-ZEN-001 2013 19 20 21 27 28 F. Specification 6000kVA, 4160V, 824A, 60Hz, 3Ph 6000kVA, 4160V, 824A, 60Hz, 3Ph 4160V, 2000A, 60Hz, 3Ph 4160V, 2000A, 60Hz, 3Ph 4160V, 2000A, 60Hz, 3Ph 4160V, 2000A, 60Hz, 3Ph 4160V, 2000A, 60Hz, 3Ph 4000kVA, 555A, 4160V, 60Hz, 3Ph 1600A, 480V, 60Hz, 3Ph 1600A, 480V, 60Hz, 3Ph 1600A, 480V, 60Hz, 3Ph 3000A, 480V, 60Hz, 3Ph 2500kVA, 480V, 3000A, 60Hz, 3Ph 2500kVA, 480V, 3000A, 60Hz, 3Ph 4,16kVA, 4160V, 3000A, 60Hz, 3Ph 625kVA, 480V,752A, 60Hz, 3Ph 480V, 1200A, 60Hz, 3Ph 480V, 1200A, 60Hz, 3Ph 480V, 1200A, 60Hz, 3Ph 480V, 3000A, 60Hz, 3Ph 2500kVA, 480V, 3000A, 60Hz, 3Ph 480V, 1200A, 50Hz, 3Ph Piping System No Line No. Diemeter (Inch) Des. Pres. (Psig) Des. Temp (°F). Year Used Service 1 2 3 4 5 6 7 8 9 10 11 20-FH-20-201-AA2 2"-CP-15-001-CA1 2"-CP-15-003-CA1 8"-CP-15-2022-CA1 6"-GP-CD1-21-033 10"-GP-25-103-CA2R 20"-FH-20-001-AA2 20"-FH-20-101-AA2 3"-FH-AA2-43-1021 3"-FH-AA2-43-1023 4"-FH-20-008-AA2 20 2 2 8 6 10 20 20 3 3 4 600 1350 1350 1400 1250 1250 700 600 1250 1250 1250 200 120 120 120 650 150 246 246 175 175 175 2018 1998 2017 1998 2017 2017 1998 2018 2018 2018 2018 High Pressure Flare Condensate Condensate Condensate Process Gas Process Gas High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Line No. Diemeter (Inch) Des. Pres. (Psig) Des. Temp (°F). Year Used Service 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 4"-FH-20-208-AA2 6"-FH-20-213-AA2 2"-DC-21-004-AA2 2"-DC-21-074-AA2 2"-DC-21-078-CD1 2"-DC-21-174-AA2 2"-GL-41-211-CA3 2"-GL-41-303-CA3 2"-GL-41-311-CA3 2"-GL-CA3-27-4001 2"-GL-CA3-47-4001 2"-GL-CA3-47-4025 4"-GP-CD1-24-1007 4"-GP-CD1-24-1057 6"-GP-CD1-24-2004 6"-GP-CD1-24-2005 6"-GP-CD1-24-2026 6"-GP-CD1-24-2027 6"-GP-CD1-24-2016 6"-GP-21-034-CD1 6"-GP-CD1-24-1005 6"-GP-CD1-24-1008 6"-GP-CD1-24-1026 6"-GP-CD1-24-1027 6"-GP-21-134-CD1 6"-GP-CD1-24-1016 2"-CP-21-079-CD1 2"-GP-21-046-DD1 2"-GP-21-047-DD1 2"-GP-21-048-DD1 2"-DA-25-114-AA2 2"-DA-25-117-AA2 2"-DA-25-119-AA2 2"-DA-25-120-AA2 2"-DA-25-134-AA2SR 2"-DA-25-136-AA2 2"-DA-25-137-AA2 2"-DA-25-216-AA2 2"-DA-25-223-AA2 2"-DA-25-224-AA2 2"-DA-25-227-AA2 2"-DA-25-301-AA2 2"-DA-25-303-AA2 4"-FH-25-101-CA2SR 8"-FH-25-102-AA2 4 6 2 2 2 2 2 2 2 2 2 2 4 4 6 6 6 6 6 6 6 6 6 6 6 6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 8 1000 1250 1250 1123 1250 1372 1250 1250 1250 1250 1250 1250 1250 1123 1250 1250 1250 1250 1250 1123 1250 1123 1250 1123 1250 1250 1250 1250 1250 1250 75 75 75 75 180 180 180 1250 75 75 75 1250 1250 1250 1250 175 35 350 350 350 175 175 175 175 175 175 175 150 350 350 350 350 350 350 350 150 350 150 350 350 150 350 120 120 120 300 300 300 300 250 250 150 150 300 300 190 200 150 150 150 1998 2010 2019 2019 2019 1998 2017 2017 1998 1998 2017 1998 2017 2017 2017 1998 1998 1998 2017 2017 2017 2017 2017 1998 2017 2017 2019 2019 2019 2019 2014 2010 1998 2014 1998 2014 2014 2014 2014 2014 2014 2014 2007 2017 2017 High Pressure Flare High Pressure Flare Close Drain Close Drain Close Drain Close Drain Glycol Glycol Glycol Glycol Glycol Glycol Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Process Gas Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain Chemical Drain High Pressure Flare High Pressure Flare Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN PT. FAST TECHNICAL SERVICES INDONESIA No Line No. Diemeter (Inch) Des. Pres. (Psig) Des. Temp (°F). Year Used Service 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 8"-FH-25-203-AA2 8"-FH-25-303-AA2 8"-FH-AA2-43-1015 8"-FH-AA2-43-1053 12"-FH-25-104-AA2 12"-FH-25-105-AA2 12"-FH-25-204-AA2 12"-FH-25-205-AA2 10"-FH-AA2-43-1020 3"-SC-46-006-AA4 2"-GL-41-213-CA3 2"-GL-41-221-AA2 2"-GL-41-224-AA2 2"-GL-41-313-CA3 2"-GL-41-321-AA2 2"-GL-41-324-AA2 2"-GL-AA2-47-4010 2"-GL-41-214-AA3 0,75"-DC-AA2-62-4005 0,75"-DC-AA2-62-4006 0,75"-DC-AA2-62-4004 2"-DC-41-103-CA2SR 2"-DC-41-203-CA2SR 2"-DC-41-301-AA2 2"-DC-41-303-CA2SR 2"-DC-CA2SR-27-1000 8 8 8 8 12 12 12 12 10 3 2 2 2 2 2 2 2 2 0,75 0,75 0,75 2 2 2 2 2 1250 1250 1250 1250 150 150 150 150 1250 147 1153 150 150 1153 150 150 150 150 1250 1250 1250 1250 1250 1250 1250 1250 150 150 150 175 200 200 200 200 175 245 237 450 450 237 450 200 200 200 175 175 175 175 175 175 175 175 2017 1998 2017 2017 2017 2017 2017 2017 1998 2013 1998 2019 1998 1998 2019 1998 2019 1998 1998 1998 1998 2014 2014 2010 1998 1998 High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare High Pressure Flare Steam Condensate Glycol Glycol Glycol Glycol Glycol Glycol Glycol Glycol Close Drain Close Drain Close Drain Close Drain Close Drain Close Drain Close Drain Close Drain Office PT. FAST TECHNICAL SERVICES INDONESIA : Perumahan Pondok Permata Suci, Jl. Gardenia 1 No. 52, Ds. Suci, Kec. Manyar, Kab. Gresik - Jawa Timur SERVING FOR BETTER QUALITY LAMPIRAN