Version 7.4.5 PVsyst TRIAL PVsyst - Simulation report Standalone system Project: Project_2 Variant: Chile F Standalone system with batteries System power: 25.38 MWp Tranque Sloman - Chile PVsyst TRIAL PVsyst TRIAL PVsyst TRIAL Author PVsyst TRIAL Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL Project summary Geographical Site Situation Tranque Sloman Chile Latitude Longitude Altitude Time zone Project settings -21.80 °S -69.49 °W 911 m UTC-4 Albedo 0.20 Meteo data Tranque Sloman Meteonorm 8.1 (2012-2019), Sat=25% - Synthetic System summary PVsyst TRIAL Standalone system Standalone system with batteries PV Field Orientation User's needs Seasonal tilt adjustment azimuth Summer Tilt winter May-June-July- 0° 25 ° 50 ° Fixed constant load 6621 kW Global 58.00 GWh/Year System information PV Array Nb. of modules Pnom total Battery pack Technology Nb. of units Voltage Capacity 36250 units 25.38 MWp Lithium-ion, LFP 5000 units 48 V 5600000 Ah PVsyst TRIAL Results summary Useful energy from solar 58000004 kWh/year Missing Energy 0 kWh/year Excess (unused) 1592427 kWh/year Specific production 2286 kWh/kWp/year Perf. Ratio PR Available solar energy 61337629 kWh/year Solar Fraction SF 80.60 % 100.00 % Table of contents Project and results summary General parameters, PV Array Characteristics, System losses Main results Loss diagram Predef. graphs 2 3 5 6 7 PVsyst TRIAL PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 2/7 Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL General parameters Standalone system Standalone system with batteries PV Field Orientation Orientation Seasonal tilt adjustment azimuth Summer Tilt winter May-June-July- Sheds configuration No 3D scene defined Models used Transposition Perez Diffuse Perez, Meteonorm Circumsolar separate 0° 25 ° 50 ° User's needs Fixed constant load 6621 kW Global 58.00 GWh/Year PVsyst TRIAL PV Array Characteristics PV module Battery Manufacturer Model (Original PVsyst database) Unit Nom. Power Number of PV modules Nominal (STC) Modules Generic CPA611HDGDC-700 700 36250 25.38 1450 string x 25 At operating cond. (50°C) Pmpp U mpp I mpp Wp units MWp In series Manufacturer Model Technology Nb. of units Discharging min. SOC Stored energy Generic ULTRA 175 48V 1120Ah Lithium-ion, LFP 5000 in parallel 10.0 % 241920.0 kWh Battery Pack Characteristics Voltage Nominal Capacity Temperature 48 V 5600000 Ah (C10) Fixed 20 °C PVsyst TRIAL 23.85 MWp 983 V 24259 A Controller Universal controller Technology Temp coeff. Battery Management control MPPT converter -5.0 mV/°C/Elem. Converter Maxi and EURO efficiencies Threshold commands as Charging Discharging SOC calculation SOC = 0.96 / 0.80 SOC = 0.10 / 0.35 97.0 / 95.0 % Total PV power Nominal (STC) Total Module area 25375 kWp 36250 modules 112605 m² PVsyst TRIAL Array losses Thermal Loss factor DC wiring losses Module temperature according to irradiance Uc (const) 20.0 W/m²K Uv (wind) 0.0 W/m²K/m/s Global array res. Loss Fraction Module Quality Loss Module mismatch losses Strings Mismatch loss Loss Fraction Loss Fraction Loss Fraction -0.8 % Serie Diode Loss 0.65 mΩ 1.5 % at STC 2.0 % at MPP Voltage drop Loss Fraction 0.7 V 0.1 % at STC 0.2 % PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 3/7 Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL Array losses IAM loss factor Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290 0° 30° 50° 60° 70° 75° 80° 85° 90° 1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000 PVsyst TRIAL PVsyst TRIAL PVsyst TRIAL PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 4/7 Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL Main results System Production Useful energy from solar Available solar energy Excess (unused) 58000004 kWh/year 61337629 kWh/year 1592427 kWh/year Loss of Load Time Fraction Missing Energy Perf. Ratio PR Solar Fraction SF 80.60 % 100.00 % Battery aging (State of Wear) Cycles SOW Static SOW 0.0 % 0 kWh/year Normalized productions (per installed kWp) 97.0 % 90.0 % Performance Ratio PR PVsyst TRIAL Balances and main results PVsyst TRIAL GlobHor GlobEff E_Avail EUnused E_Miss E_User E_Load SolFrac kWh/m² kWh/m² kWh kWh kWh kWh kWh ratio January 264.4 226.4 5015744 0 0.000 4926028 4926028 1.000 February March April May June July August September October November December 226.2 234.2 192.1 164.2 144.3 157.9 187.2 214.9 255.6 268.1 279.1 211.4 245.6 227.5 231.0 221.4 237.9 231.2 236.4 249.3 235.0 231.6 4659029 5329181 4982745 5071116 4889936 5302315 5145538 5201160 5426029 5179636 5135200 139 246920 70480 31566 290 171696 73638 302054 344837 268503 82306 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4449315 4926028 4767124 4926028 4767124 4926028 4926028 4767124 4926028 4767124 4926028 4449315 4926028 4767124 4926028 4767124 4926028 4926028 4767124 4926028 4767124 4926028 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 Year 2588.3 2784.7 61337629 1592427 0.000 58000004 58000004 1.000 PVsyst TRIAL Legends GlobHor GlobEff E_Avail EUnused E_Miss Global horizontal irradiation Effective Global, corr. for IAM and shadings Available Solar Energy Unused energy (battery full) Missing energy E_User E_Load SolFrac Energy supplied to the user Energy need of the user (Load) Solar fraction (EUsed / ELoad) PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 5/7 Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL Loss diagram 2588 kWh/m² Global horizontal irradiation +9.6% Global incident in coll. plane -1.81% IAM factor on global 2785 kWh/m² * 112605 m² coll. Effective irradiation on collectors efficiency at STC = 22.54% PV conversion 70670142 kWh Array nominal energy (at STC effic.) PVsyst TRIAL -0.26% PV loss due to irradiance level -4.99% PV loss due to temperature +0.75% Module quality loss -2.15% Mismatch loss, modules and strings -1.42% Ohmic wiring loss -2.45% Unused energy (battery full) 62382411 kWh Effective energy at the output of the array -4.22% -1.85% Converter Loss during operation (efficiency) Converter Loss over nominal conv. power PVsyst TRIAL -0.01% Converter Loss due to power threshold 0.00% Converter Loss over nominal conv. voltage 0.00% Converter Loss due to voltage threshold 59745202 kWh Converter losses (effic, overload) Battery Storage Direct use 39.2% Stored 60.8% +0.02% Battery Stored Energy balance -0.35% Battery efficiency loss -2.33% Charge/Disch. Current Efficiency Loss -0.15% Battery Self-discharge Current 58000004 kWh Energy from the sun 58000004 kWh Energy supplied to the user 58000004 kWh Energy need of the user (Load) PVsyst TRIAL PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 6/7 Project: Project_2 Variant: Chile F PVsyst V7.4.5 VC0, Simulation date: 02/02/24 02:11 with v7.4.5 PVsyst TRIAL Predef. graphs Daily Input/Output diagram PVsyst TRIAL PVsyst TRIAL PVsyst TRIAL PVsyst TRIAL 02/02/24 PVsyst Evaluation mode Page 7/7