Fitness for Service Assessment Assessment Type API 579 PART 5 LEVEL 1 Description Standard API 579-1/ASME FFS-1, June, 2016 Assessment of Local Metal Loss - Straight Pipe Facility Client Item ID Client Rep Item CML Item Description PAUT-B & GWT ASSESSMENT INPUTS Conditions External Defect Location T= 100 Operating Temperature (°F) Design Assessment Condition P= 1480 Pressure (psi) B31.3 Piping Class Material Design Factors Ec = S= 20000 Allowable Stress (psi) EL = tSL = Do = 8.625 Outside Diameter (in) RSFa = A106 Gr B tnom = Inspection Data s= Material 0.5 Fabricated Thickness (in) 1.50 Pit Length Longitudinal Plane (in) YB31 = 1 Circumferential Weld Joint Efficiency 1 Longitudinal Weld Joint Efficiency 0 Thickness Required for Supplemental Loads (in) 0.9 Allowable Remaining Strength Factor 0.4 Material Yb31 Value trd = 0.483 Uniform Thickness Away From Metal Loss (in) 0.017 0.02 Uniform Metal Loss (in) Future Corrosion Allowance (in) 0.02 Future Corrosion Allowance - Metal Loss (in) 2243 Circumferential MAWP MAWP = 4698 Longitudinal MAWP MAWP = 2243 MAWP c= Lmsd = 27.00 3.40 Pit Length Circumferential Plane (in) Distance to Nearest Discontinuity (in) tmm = 0.241 Minimum Measured Thickness (in) LOSS = FCA = FCAml = 0.4630 Corroded thickness away from LTA Step 7 MAWPC = CALCULATED VALUES Step 2 tC = L Step 3 Above See Inspection Data for values Step 4 Step 5 Step 8 Rt = 0.4773 Remaining Thickness Ratio λ= 1.0209 Longitudinal Flaw Length Parameter Mt = 1.2067 Rt-min = 0.6066 Flaw Size Criteria No - Use RSF OK OK Rt ≥ 0.2 tmm-FCAml ≥ 0.05" OK Lmsd ≥ 1.8√(Dtc) RSF = MAWPr = Folias Factor Minimum Acceptable Rt Value Rt > Rt-min 0.8420 Remaining Strength Factor No - Use MAWPr RSF ≥ RSFa 2099 Reduced MAWP (psi) Step 6 N/A RESULTS ACCEPTABLE The level 1 assessment criteria is satisfied, fit for continued operation at assessment conditions. Notes Assumes original 100% RT weld quality inspection Evaluated By Position Position Date Date THIS CONFIDENTIAL REPORT IS FURNISHED FOR THE USE OF THE CLIENT ONLY. THERE ARE NO IMPLIED OR EXPRESS WARRANTIES OR GUARANTEES OF ANY KIND IN CONNECTION WITH THIS INSPECTION. THE ITEMS INSPECTED WERE IN THE REPORTED CONDITION LISTED ABOVE AT THE TIME OF THE INSPECTION ONLY. FURTHER DISCLAIMED IS ANY LIABILITY FOR ANY DAMAGE OR DEFECTS NOT FOUND DURING THIS INSPECTION.