1 3 2 SEE DETAIL 1 M 5 5 4 TO 2ND FLOOR B.I. PIPE SCH. 40, ERW (100 mm) SEE DETAIL 6 M 5 6 FLUSHING (25mm) ITC (25 mm) TO 2ND FLOOR B.I.PIPE SCH. 40,ERW (80 mm) RISER SEE DETAIL D 3 M6 FCV JP 1 FP 1 32 mm 25 mm ACV ESD RECORDS 25 mm 80 mm C' 25 mm PWD FE-1 FE-1 32 mm HE PANTRY/ EMPLOYEE LOUNGE PALD RECORDS 25 mm FE-1 FE-1 SUPPLY ROOM SHE 65 mm C FE-1 FE-1 SERVER HE SHE B' 32 mm 25 mm FE-1 EXAMINATION SERVICES DIVISION 50 mm PROCESSING RM. 25 mm 32 mm PUBLIC ASSISTANCE & LIASON DIVISION CASHIER STD RESPONSE FIRE SPRINKLER (K=5.6) TYPICAL TO 50 NOS. 25 mm SEE DETAIL FE-2 25 mm 25 mm ELECT'L ROOM FE-1 40 mm B FHC 25 mm FE-2 32 mm 25 mm 32 mm 25 mm 40 mm COMMEX ROOM 25 mm A' 2 M6 SIDE WALL PENDENT TYPE (K=5.6) CV FDC PACD LOBBY LACTATION ROOM A GROUND FLOOR FIRE PROTECTION LAYOUT 1 M 1 SCALE ALICIA DELA ROSA BALA 1:100 M CHAIRPERSON, CSC DATE: GROUND FLOOR FIRE PROTECTION LAYOUT JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 1 9 1 3 2 5 4 TO 3rd FLOOR B.I. PIPE SCH. 40, ERW (80 mm) 6 TO 3RD FLOOR B.I.PIPE SCH.40,ERW (65 mm) FLUSHING (25mm) RISER D FE-1 FCV 32 mm FROM 2ND FLOOR B.I.PIPE SCH.40,ERW (80MM) OFFICE 80 mm 25 mm 32 mm RD QUARTERS A.R.D. ARD OFFICE SECRETARY HE MEETING RM. FE-1 PWD FE-1 25 mm FE-1 SHE QUARTERS FE-1 C 32 mm T&B R.D. 25 mm FE-2 SECRETARY 25 mm 65 mm 25 mm MSD FE-1 FE-1 SIDE WALL PENDENT TYPE (K=5.6) FE-2 25 mm 32 mm 40 mm 25 mm LOUNGE 25 mm 25 mm 25 mm I. T. ROOM FHC 32 mm 50 mm B STD RESPONSE FIRE SPRINKLER (K=5.6) TYPICAL TO 63 NOS. 25 mm 32 mm B' A' PANTRY 25 mm MEDITATION C' FROM GROUND FLOOR B.I.PIPE SCH.40,ERW (100MM) T&B ARD 25 mm HRD 25 mm 32 mm FE-1 SIDE WALL PENDENT TYPE (K=5.6) A SECOND FLOOR FIRE PROTECTION LAYOUT 1 M 2 SCALE ALICIA DELA ROSA BALA 1:100 M CHAIRPERSON, CSC DATE: SECOND FLOOR FIRE PROTECTION LAYOUT JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 2 9 1 3 2 5 4 TO 4th FLOOR B.I. PIPE SCH. 40, ERW (65 mm) RISER 6 TO 4TH FLOOR B.I.PIPE SCH.40,ERW (40 mm) FLUSHING (25mm) RISER D FCV 32 mm FROM 2ND FLOOR B.I.PIPE SCH.40,ERW (80MM) 25 mm QUARTERS 32 mm QUARTERS QUARTERS 40 mm QUARTERS C SHE 25 mm 65 mm C' FROM 3RD FLOOR B.I.PIPE SCH.40,ERW (40MM) 25 mm FE-1 PANTRY/ MESS HALL HE FE-1 FE-1 FE-1 PWD FE-1 FE-2 FHC H A L L W A Y 25 mm 32 mm 50 mm B' STOCK ROOM FE-1 FE-1 25 mm STD RESPONSE FIRE SPRINKLER (K=5.6) TYPICAL TO 50 NOS. COA HEARING ROOM/LIBRARY ANTI RED TAPE UNIT B FE-1 25 mm 25 mm FE-1 32 mm SIDE WALL PENDENT TYPE (K=5.6) FE-1 25 mm FE-2 FE-1 H A L L W A Y LSD LEGAL FE-1 25 mm 32 mm 25 mm SIDE WALL PENDENT TYPE (K=5.6) FE-1 40 mm A' 25 mm FE-1 PSED 32 mm 25 mm A THIRD FLOOR FIRE PROTECTION LAYOUT 1 M 3 SCALE ALICIA DELA ROSA BALA 1:100 M CHAIRPERSON, CSC DATE: THIRD FLOOR FIRE PROTECTION LAYOUT JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 3 9 1 3 2 5 4 6 FLUSHING (25mm) RISER D FCV C' FROM 3RD FLOOR B.I.PIPE SCH.40,ERW (40MM) AVR FROM 3RD FLOOR B.I.PIPE SCH.40,ERW (65MM) 32 mm SHE SHE 25 mm FE-1 PWD 25 mm 50 mm MALE DORM FE-2 C MALE DORM 32 mm 25 mm 25 mm 32 mm 25 mm HE FE-1 FE-1 25 mm FHC FE-1 25 mm TRAINING SUPPLY STD RESPONSE FIRE SPRINKLER (K=5.6) TYPICAL TO 50 NOS. FOOD PREP. B' 32 mm 25 mm B 25 mm FE-1 CIVIL SERVICE COMMISSION LEARNING & DEVELOPMENT CENTER FE-2 32 mm 25 mm 25 mm 32 mm A' SIDE WALL PENDENT TYPE (K=5.6) FE-1 L O B B Y 25 mm SIDE WALL PENDENT TYPE (K=5.6) 25 mm FE-1 A FOURTH FLOOR FIRE PROTECTION LAYOUT 1 M 4 SCALE ALICIA DELA ROSA BALA 1:100 M CHAIRPERSON, CSC DATE: FOURTH FLOOR FIRE PROTECTION LAYOUT JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 4 9 DRAIN RISER TO LEVEL ABOVE COMBINATION STANDPIPE/RISER TO LEVEL ABOVE CONTROL VALVE PRESSURE GAUGE TO FIRE SPRINKLER SYSTEM PRESSURE REDUCING VALVE CAPPED OUTLET CHECKED VALVE FLOW SWITCH TO SPRINKLER SYSTEM PRESSURE RELIEF VALVE AUXILARY DRAIN VALVE SIGHT GLASS UNION INSPECTORS TEST VALVE TO LEVEL BELOW CAPPED OUTLET ON DRAIN RISER FIRE PROTECTION 1 M 5 FLOOR CONTROL VALVE DETAIL CISTERN WALL 6mm THK. x 125mm x 125mm STAINLESS STEEL ANCHORAGE PLATE 6mm THK. x 125mm x 125mm STAINLESS STEEL ANCHORAGE PLATE CISTERN TANK DETAIL 6mm THK. x 125mm x 125mm STAINLESS STEEL ANCHORAGE PLATE STEEL PIPE SCHEDULE 40 6mm THK. x 125mm x 125mm STAINLESS STEEL ANCHORAGE PLATE 6mm THK. x 125mm x 125mm STAINLESS STEEL ANCHORAGE PLATE STEEL PIPE MID-SPAN SUPPORT STEEL PIPE @ 0.40 M.O.C. LADDER RUNG 1 4" x 4" x 4" S/S WITH RUBBER BACKING BOTTOM OF CISTERN TANK 1 4" x 4" x 4" S/S PLATE WITH RUBBER BACKING EXPAND BOLT 1 12" x 3mm THK. BENDED S/S FLAT BAR 1 4" x 4" x 4" S/S WITH RUBBER BACKING CISTERN WALL STEEL PIPE MID-SPAN SUPPORT STEEL PIPE SCHEDULE 40 STEEL PIPE SCHEDULE 40 1 4" x 4" x 4" S/S WITH RUBBER BACKING STEEL PIPE SCHEDULE 40 RUBBER BACKING STEEL PIPE @ 0.40 M.O.C. LADDER RUNG STEEL PIPE MID-SPAN SUPPORT FIRE PROTECTION 2 M 5 ALARM CHECK VALVE ASEMBLY ALICIA DELA ROSA BALA NTS CHAIRPERSON, CSC DATE: FLOOR CONTROL VALVE DETAIL LADDER RUNG DETAIL ISOMETRY-LADDER RUNG DETAIL ALARM CHECK VALVE ASSEMBLY JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 5 9 BRANCHLINE PRESSURE GAUGE VALVE (1500mm FROM FINISHED FLOOR) 90 RISE NIPPLE WALL FASTENER (TYPICAL) GLASS 30m HOSE RANGE PIPE SIGHT GLASS INSPECTOR'S TEST VALVE NOT OVER 1.8 M (6FT) ABOVE FLOOR DROP NIPPLE FIRE HOSE VALVE ACCESS HANDLE FIRE EXTINGUISHER 10LBS DRY CHEMICAL (ABC TYPE) COUPLING REDUCER PENDENT TYPE SPRINKLER HEAD DEFLECTOR TUBULAR PIPE FRONT ELEVATION FINISHED FLOOR LINE FLANGE ANCHOR BOLTED FLOOR LINE PLAN 1 M 6 DETAIL "A" FIRE HOSE CABINET DETAIL 2 M 6 NTS BLACK IRON/ GALVANIZED IRON PIPE SLEEVE BLACK IRON/ GALVANIZED IRON PIPE SLEEVE NTS EXPANSION SHIELD PROVIDED W/ ROCK WOOL MINERAL WOOL OR APPROVED EQUAL FILLED W/ FIRE RATED SEALANT FIRE STOPPING OR APPROVED EQUAL (SEE TABLE) FILLED W/ FIRE RATED SEALANT FIRE STOPPING OR APPROVED EQUAL (SEE TABLE) 65 X 65 X 7mm STEEL ANGLE EXPANSION SHIELD SPRINKLER RISER WELD (TYPICAL) BLACK IRON/ GALVANIZED IRON PIPE SLEEVE PROVIDED W/ ROCK WOOL MINERAL WOOL OR APPROVED EQUAL DETAIL "B" INSPECTOR'S TEST CONNECTION & FLUSHING DETAIL 3 M 6 NTS FIRE SPRINKLER (PENDENT TYPE) DETAIL CONCRETE WALL OR BEAM HANGER ROD PIPE PASSING THROUGH R.C. FLOOR SLAB ADJUSTABLE RING HANGER (CARBON STEEL FLAT BAR) SPRINKLER PIPE 4 M 6 PIPE SLEEVE DETAIL PIPE RISER BRACKET DETAIL 5 M 6 6 M 6 PIPE HANGER DETAIL ALICIA DELA ROSA BALA CHAIRPERSON, CSC DATE: FIRE HOSE CABINET DETAIL FIRE SPRINKLER (PENDENT TYPE) DETAIL INSPECTOR'S TEST CONNECTION & FLUSHING PIPE SLEEVE DETAIL PIPE RISER BRACKET DETAIL PIPE HANGER DETAIL JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 6 9 FCV FOURTH FLOOR LINE TOP OF BEAM CEILING LINE FHC FCV FOURTH FLOOR LINE TOP OF BEAM CEILING LINE LEGEND: BV BUTTERFLY VALVE FCV FLOOR CONTROL VALVE YS Y-STRAINER FJ FLEXIBLE JOINT PRV PRESSURE RELIEF VALVE PG PRESSURE GAUGE CV CHECK VALVE ACV ALARM CHECK VALVE FHC FCV FOURTH FLOOR LINE TOP OF BEAM CEILING LINE FHC GV GATE VALVE FV FLOAT VALVE FHC INDOOR FIRE HOSE CABINET STD RESPONSE FIRE SPRINKLER (K=5.6) FCV FOURTH FLOOR LINE TOP OF BEAM CEILING LINE ACV F.E FIRE EXTINGUISHER FDC FIRE DEPARTMENT CONNECTION F.E CONCENTRIC REDUCER FHC GV 40 mm GV (FLUSHING) 100 L GV (ITC) GROUND FLOOR FINISH LINE 20 mm GV CV CV FDC 80 mm PRV PG FJ OSV CV GV FLEXIBLE PIPE CONNECTOR FJ PG YS OSV WATER SUPPLY YS GV CV PG FJ FP 1 FJ PG GV GV GV JP 1 NATURAL GRADE LINE 80 mm 32 mm FIRE PROTECTION SCHEMATIC DIAGRAM 1 M 7 ALICIA DELA ROSA BALA CHAIRPERSON, CSC DATE: FIRE PROTECTION SCHEMATIC DIAGRAM JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 7 9 PUMP CAPACITY COMPUTATION NUMBER OF ACTIVE SPRINKLERS = WHERE: FIRE PROTECTION AREA MAX. AREA OPERATION OF SPRINKLER = 0.1 AREA OF OPERATION = 200 SQ. FT VOLUME FLOW = 15 PSI X 2.31 FT. 1 psi TOTAL VOLUME FLOW BHP = FLOW (GPM) X TDH (FT) X S.G 3960 X Eff. = 350 GPM X 131 FT. X 3960 X 0.6 6 FT X 295 FT X 1.5 100 FT 1 = 19.3 Hp Hf = 26.6 FT = 300 GPM HOSE STREAM ALLOWANCE TL = PIPE TOTAL LENGTH, FT Hf = = 0.1 GPM x 200 sq. ft x 15 sprinkler SQ. FT VOLUME FLOW BRAKE HORSEPOWER Hf = 90 M X 3.28 FT = 295 FT 1M GPM SQ. FT LIGHT HAZARD WHERE: TDH = 34.65 FT + 0 FT + 70 FT + 26.6 FT = 50 GPM (NFPA 13) 2 BHP = 20 Hp >COMMERCIAL SIZE AVAILABLE TDH = 131 FT 1 = 18.3 m - -3m 3.28 ft 1m = 350 GPM Hf = (4 to 10 ft) x TL x 1.5 100 ft PUMP CAPACITY COMPUTATION 1 M 8 FOR JOCKEY PUMP TANK VOLUME FLOW = = FLOW = 10% OF FIRE PUMP CAPACITY 10% X ASSUMING 15 MINS. OPERATION 350 GPM V = 350 GAL X MIN 15 MINS = 5250 GALS X 3.785 Li 1 GAL X 1M 1000 Li 35 GPM V = 20 M TDH = 112% OF FIRE PUMP SAY = 112% X 131 FT L = 3M W = 3M = 147 FT 20 M BHP = FLOW (GPM) X TDH (FT) 3960 X Eff. H = 2.2 + H = 2.5 M = 35 GPM X 147 FT 3960 X 0.6 BHP 2 M 8 (0.3M AIRSPACE) TANK DIMENSION: 3.0M(L) X 3.0M(W) X 2.5 M(H) = 2.0 Hp > COMMERCIAL SIZE AVAILABLE JOCKEY PUMP COMPUTATION 3 M 8 TANK VOLUME COMPUTATION ALICIA DELA ROSA BALA CHAIRPERSON, CSC DATE: PUMP CAPACITY COMPUTATION JOCKEY PUMP COMPUTATION TANK VOLUME COMPUTATION JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 8 9 GENERAL NOTES: FIRE PROTECTION EQUIPMENT SCHEDULE EQUIP. NO. FP-1 EQUIPMENT NAME Fire Pump SPECIFICATION SUMMARY Type: HORIZONTAL PUMP ELECTRICAL QTY Kw Area Served Ph V Hz 1 3 220 60 See Plan 1 3 220 60 See Plan Capacity: 350 GPM Head: 131 ft TDH Electric Driven Complete with Controller & Accessories BHP: 20 HP JP-1 Jockey Pump Type: Vertical in-line Turbine Capacity: 35 GPM Head: 147 ft TDH Electric Driven Complete with Controller & Accessories BHP: 2.0 HP Type: Underground Fire Water FWT-1 Fire Water Tank Tank 1 See Plan 4 See Plan Capacity: 20 m3 Length: 3.0 m Width: 3.0 m Depth: 2.2 m + 0.3 m airspace = 2.5 m Total Effective Capacity: 22.5 m3 (For 15 mins. Operation) FHC-1 Fire Hose Cabinet Type: Indoor Surface Type Hose: 40 mm diam. X 30 m hose length, double Jacket with 10 Lbs. ABC Fire Extinguisher FE-1 Fire Extinguisher Type: 10 Lbs. ABC 35 See Plan FE-2 Fire Extinguisher Type: 20 Lbs. ABC 8 See Plan 1 M 9 FIRE PROTECTION EQUIPMENT SCHEDULE Sealant Requirements in cubic centimeter per 6mm ( 25 32 40 50 65 80 100 3 M 9 Pipe O.D. mm 33.4 42.4 48.3 60.3 73 88.9 114.3 of installed depth Diameter of Opening, CM (Area of Opening,mm ) PIPE Size Trade Size mm 1 in) 4 2 M 9 50 Area mm 2 876 1412 1832 2856 4185 6207 10261 65 80 100 125 Volume of Sealant(mm3) 6900 15000 20000 31700 23300 38500 47100 SEALANT REQUIREMENT SCHEDULE Pipe Hanger PIPE SLEEVE Rod Size mm 10 10 10 10 10 10 12 12 12 Pipe Size (mm) Sleeve Size (mm) 25 50 32 65 40 80 50 100 65 100 80 125 100 150 Trade Size mm 15 20 25 32 40 50 65 80 100 150 4 M 9 GENERAL NOTES Size of Steel Flat Bar (Th x W) mm 3.2 x 25 3.2 x 25 3.2 x 25 3.2 x 25 3.2 x 25 3.2 x 25 5 x 32 5 x 32 5 x 32 PIPE HANGER SCHEDULE 5 M 9 PIPE SLEEVE SCHEDULE ALICIA DELA ROSA BALA CHAIRPERSON, CSC DATE: FIRE PROTECTION EQUIPMENT SCHEDULE GENERAL NOTES SEALANT REQUIREMENT SCHEDULE PIPE HANGER SCHEDULE PIPE SLEEVE SCHEDULE JOHN CARLO N. GANI RUEL O. BODESTYNE ENGINEERING ASSISTANT ENGINEER III JOE CRIS M. MADARANG FELICIANO T. GARROTE ENGINEER III OIC, EQUIPMENT MANAGEMENT DIVISION SEVILLA, SAN FERNANDO, LA UNION DATE: DATE: ALBERTO B. ESQUEJO, JR. EMMANUEL W. DIAZ, CESE CHIEF, PLANNING AND DESIGN DIVISION OIC - ASSISTANT REGIONAL DIRECTOR DATE: DATE: RONNEL M. TAN, CESO IV REGIONAL DIRECTOR DATE: 9 9