METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT ● PROJECT CODE : B70170EA ● PROJECT NAME : PULAU INDAH COMBINED CYCLE POWER PLANT ● OWNER : PULAU INDAH POWER PLANT SDN BHD ● EQUIPMENT NAME : GENERAL Purpose C 03/03/2022 B 03/03/2022 A 08/02/2022 Rev. No. □ For Information □ For Approval ■ For Construction ● DOCUMENT NUMBER : 0-WD000-CM620-10002 ● TITLE Page 1 of 31 : METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT Zafran Zaharol H.W Park J.H Lim Y.H Ku Zafran Zaharol H.W Park J.H Lim Y.H Ku Zafran Zaharol WS Low Almudin H.W Park PREPARED REVIEWED CHECKED APPROVED □ For ( ) APPROVED DATE CONTRACTOR OWNER OWNER / OE OWNER’S ENGINEER PULAU INDAH POWER PLANT SDN. BHD. JACOBS ENGINEERING MALAYSIA SDN. BHD. OFFSHORE CONTRACTOR POSCO ENGINEERING AND CONSTRUCTION ONSHORE CONTRACTOR PEC POWERCON SDN. BHD. MITSUBISHI CORPORATION SUBCONTRACTOR EQUATOR ENGINEERING SDN BHD PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 2 OF 20 REVISION HISTORY REV. DESCRIPTIONS AND/OR REVISED SHEETS REFERENCE REV. DATE A First issue. 08/02/2022 B Second issue (Amended as per DRS-0-WD000-CM620-10002) 03/03/2022 C Issue for construction 01/04/2022 PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 3 OF 31 Table of Contents NO 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 DESCRIPTION INTRODUCTION DEFINITION & ABBREVIATION REFERENCE CODES AND STANDARDS SCOPE OF WORKS RESPONSIBILITY EQUIPMENT AND TOOLS ERECTION PROCEDURE PAGE NO 4 4 4 5 7 10 11 7.1 TRANSPORTATION, HANDLING AND RECEIVING INSPECTION 7.2 PREPARATION WORKS 7.3 INSTALLATION WORKS OF HORIZONTAL PUMP 7.4 INSTALLATION WORKS OF VERTICAL PUMP 7.5 FINAL ALIGNMENT INSPECTION 7.6 WORKING ON EXTENDED HOURS 7.7 WORKING IN CONFINED SPACE 12 12 13 14 14 15 15 QUALITY ASSURANCE AND CONTROL SAFETY, HEALTH & ENVIRONMENTAL REQUIREMENTS 15 15 9.1 SITE SAFETY AND HEALTH REQUIREMENTS 9.2 ENVIRONMENTAL REQUIREMENTS 9.3 ASSEMBLY POINT 9.4 EMERGENCY CONTACT 9.5 WELFARE AND FIRST AID 9.6 COVID-19 SAFETY MEASURE 15 16 18 18 19 19 HAZARD IDENTIFICATION, RISK ASSESSMENT & CONTROL 20 PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 4 OF 31 1.0 INTRODUCTION The purpose of this method statement is to guide on the proper and safety erection work of Rotating Equipment for Pulau Indah Combined Cycle Power Plant; as such it will be executed through disciplined approach by Contractor. This method statement attempts to include, describe and outline the methods and procedures to be adopted, and to provide specific instructions in safety and environment controls associated with the works. 2.0 DEFINITION AND ABBREVIATION AFC Approved for Construction PIPP Pulau Indah Power Plant (Owner) HSE Health, Safety & Environment POSCO Offshore Contractor FITP Field Inspection Test Plan QC Quality Control OEM Original Equipment Manufacturer 3.0 REFERENCE DOCUMENTS AND DRAWINGS 0-WD010-MZ711-10015 Lifting Safety Procedure 0-WD010-MZ711-10024 Rigging and Slinging Procedure 0-WD000-CZ250-10001 Field Inspection Test Plan for Rotating Equipment 0-WD010-MZ711-10001 HSE Management Plan 0-WD010-MZ711-10018 & 10019 Environment Protection Procedure & Waste Management Procedure PIPP-HIRARC-EESB-05 REV A PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 5 OF 31 4.0 SCOPE OF WORKS This method statement identifies the general steps, arrangements & precautions which shall be followed for the erection of Rotating Equipment. The supplier’s erection procedure precedes the method statement. If any discrepancy is found, the subcontractor shall comply with the supplier’s instruction unless the supplier give the confirmation by any correspondence. NO EQUIPMENT SYSTEM 1 Air Compressor Compressed Air system 2 Air Dryer Compressed Air system 3 Demin Water Supply Pump General Service Pump 4 Desalination & Service Water General Service Pump Supply Pump 5 Potable Water Booster Pump General Service Pump 6 Oil Unloading Pump General Service Pump 7 Oil Drain Pump General Service Pump 8 SWRO make up Pump General Service Pump 9 Condensate Drain Pump General Service Pump 10 HRSG Blowdown Transfer Pump General Service Pump 11 CWP Area Sump Pump Sump Pump 12 BSDG Trench Sump Pump Sump Pump 13 Main Cable Route Trench Sump Sump Pump Pump(#1~#13) 14 #1 HRSG Blowdown PIT Chemical Sump Sump Pump Pump 15 #2 HRSG Blowdown PIT Chemical Sump Sump Pump Pump 16 #1 CEP Area Chemical Sump Pump Sump Pump 17 #2 CEP Area Chemical Sump Pump Sump Pump 18 #1 TR Area Oily Sump Pump Sump Pump 19 #2 TR Area Oily Sump Pump Sump Pump 20 FGC Area Oily Sump Pump Sump Pump 21 Oil / Water Separator Sump Pump Sump Pump 22 CWP_Pump Circulating Water Pump 23 CWP_Motor Circulating Water Pump 24 ACWP_Pump Circulating Water Pump PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 6 OF 31 25 ACWP_Motor Circulating Water Pump 26 Hypochlorite Generator Chlorination System 27 Seawater Supply Pump for ECP Chlorination System 28 Hypochlorite Continuous Dosing Pumps Chlorination System 29 Hypochlorite Shock Dosing Pumps Chlorination System 30 Air Blowers for H2 Removal Chlorination System 31 Sump Pump for ECP Chlorination System 32 Ultrafiltration(UF) B/W pump A/B Pretreatment System 33 Filter Backwash Pump for MMF A/B Pretreatment System 34 Filter B/W blower for MMF A/B Pretreatment System 35 Filtered Water Feed pump A/B Desalination System 36 BWRO High Pressure Pump A/B Desalination System 37 CIP Pump A/B Desalination System 38 RO Flushing Pump (Motor drive) Desalination System 39 HCl Unloading Pump A/B Demineralization System 40 NaOH Unloading Pump A/B Demineralization System 41 MBP feed pump A/B Demineralization System 42 MBP Regeneration Pump A/B Demineralization System 43 Air Blower for MBP A/B Demineralization System 44 Sump Pump A/B, Demineralization System 45 Sanitary Water Transfer Pump A/B Demineralization System 46 Agitator With Motor Demineralization System 47 Potable water Feed Pump A/B Potable Water System 48 Clarifier Waste Water Treatment 49 Thickener Waste Water Treatment 50 Normal Waste Water Pump A/B Waste Water Treatment 51 Abnormal Waste Water Pump A/B Waste Water Treatment 52 Sludge Transfer Pump A/B Waste Water Treatment 53 Clarified Water Pump A/B Waste Water Treatment 54 Backwash Pump for Filter A/B Waste Water Treatment 55 Sump Pump for Pump Room A/B Waste Water Treatment 56 Oily Waste Water Feed Pump A/B Waste Water Treatment 57 Progressive Cavity Pump A/B Waste Water Treatment 58 Root blower for WWT A/B/C Waste Water Treatment 59 Air blower for sanitary A/B Waste Water Treatment 60 Chemical Pump Waste Water Treatment PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 7 OF 31 5.0 RESPONSIBILITY Site Manager Site Manager has the responsibilities for Civil, Mechanical, Electrical, Architecture, Material, Commissioning, QA/QC and safety works. Safety and Health Officer/Supervisor Safety officer and safety supervisors are responsible in ensuring that all HSE requirements are strictly adhered to at all times. Construction Manager Construction manager is responsible for this Method of Statement, he is supporting and ensuring that all entitles at the worksite actively participate. Chief Engineer Ensure the full implementation of this Method of Statement and identifies the requirements and add on resources for the effective accomplishment of the equipment installation. QA/QC Manager Responsible for the implementation of all required controlled activities. Maintain the required documentation as per approved Field Inspection Test Plan (FITP) for the final acceptance and hand over of the system. Monitor the QC personnel in their daily functions and conducts reviews of documentation and inspection / verification activities. Ensures adequately qualified and experienced QC Personnel are assigned to inspection duties. QA/QC Engineer QC Engineer shall be responsible for the QC activities, material control and traceability, nonconformance management and compilation of inspection and test. Superintendent / Supervisor Secure all necessary work permits. Confirm the availability of all materials, tools, equipment and required personnel to accomplish the work. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 8 OF 31 Lifting Supervisor Co-ordinate all lifting activities and ensure that the ground conditions are safe for any lifting operation to be performed. Be present at the workplace and supervise the lifting operation work. Brief crane operator, rigger and signalman on the safe lifting procedures prior lifting operation. To stop lifting operation if there is unsafe condition or equipment faulty and resume the operation after full rectification of the unsafe condition or repair/replace of faulty/damage equipment by competent person. Ensure all lifting equipment such as lifting gears (LG), lifting machines (LM) and lifting appliances (LA) used at the workplace have valid inspection/test certificates by an Authorized Examiner (AE). Conduct regular inspection of the LG, LM and LA for its integrity. Participate in conducting job risk assessment. Participate in conducting lifting plan for each task. Obtain approved lifting plan and ensure lifting gears are selected in accordance with those included in the lifting plan. Rigger Conduct checking of slings to be used for slinging the loads to ensure that the slings are of good construction and material and free of defects. Ensure that an adequate number of legs of the sling are used and that the slinging angle is correct so as to prevent the sling from being overloaded during the hoisting. Ascertain the weight of the load which is to be lifted and inform the crane operator of the weight of the load. Ensure that only suitable lifting gears are used in conjunction with the sling. Ensure that the load to be lifted is secure, stable and balance with center of gravity. Ensure that any loose load e.g. stones and timber etc., is placed in a receptacle to prevent it from falling during the lifting operation. To place adequate padding at the edges of the load which come in contact with the sling so as to prevent the sling from being damaged. And to conduct regular checking of all LG used and report any defect on the LG to Lifting Supervisor. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 9 OF 31 Signalman Ensure that the verification with the Rigger had been given to proceed with the lifting work. Clearance continue with the signaling to Crane Operator for hoisting the load. To give correct and clear signals in guiding the Crane Operator in the maneuver of the load safely to its destination by means of clear radio communication. To ensure that no person under suspended load. To ensure no person standing or working under the suspended load, within the Route of lifting from point to the other. Maintain clear vision of distance with the Crane Operator so that all hand signals can be clearly seen by the Crane Operator. Scaffolding Supervisor • Ensure that all its employees adhere to the standard or code of practice with respect to the selection of scaffolds, erection and possible modification. • Scaffolding Foreman, Scaffolding Supervisor who are competent must supervise the scaffolding installation or dismantling activities onsite. • Ensure all scaffolder wear required safety clothing and equipment such as gloves, overalls, helmets, safety shoes and harness, lifelines, and ensure the proper use of the safety equipment. • Carry out regular quality control checks on scaffolding materials and on erected scaffolds. • Comply with the written hand-over procedure and maintain good communication with the Scaffolding Supervisor at all times. • Ensure safe dismantling of scaffolding and site clearance upon completion of the job. Material Controller Will handle the material requisitioning, physical receipt of goods, inspection, storage and delivery of materials. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 10 OF 31 6.0 EQUIPMENT AND TOOLS No. 1 Equipment & Tools Name Theodolite / Auto Level Unit Qty Nos 1 Function Remark To survey & check foundation Chipping 2 Power Tools Nos 1 3 Mobile Crane Nos 1 4 Cement Mixer Nos 1 Foundation machine, drilling preparation, machine, grinder, modification works etc. Lifting activity Mixing of cement grout Bolt tightening, 5 Hand tools Nos 1 equipment installation PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT 7.0 ERECTION PROCEDURE Figure 1: General Work Sequence of equipment installation DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 11 OF 31 PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 12 OF 31 7.1 Transportation, Handling and Receiving Inspection a) Join inspection of the pump package with the QC Team, this will be done to check if the package received is as per packing list. b) Upon opening of the package the item will be checked for any damage during transportation and hauling, if any damage these will be reported immediately and to be documented properly. 7.2 Preparation Works a. Obtain the necessary work permit(s) from contractor to start any installation or extended works. b. Proceed with dimensional acceptance inspection of anchor bolt during foundation handover. c. Marking of centerlines on every pump foundation the x and y axis according to drawing and the bench marks. d. Locate elevation bench marks and transfer it to the nearest convenient place. This is very important for the leveling plate inspection and pump elevation check. Figure 2: Elevation inspection of packer plate e. Chip the pump foundation in accordance with the manufacturer’s recommendation. f. Install the foundation packer plate or leveling plate as per approved for construction drawing. g. Proceed with elevation/levelling inspection of packer plate as per approved for construction drawing. Levelling plate inspection shall be done and to be witnessed by the QC Engineer. Note: Pad Elevation Inspection tolerance ± 3mm PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 13 OF 31 Figure 3: Surface chipping and levelling plate installation plate 7.3 Installation Works of Horizontal Pump a. After the curing of the grouted leveling plates, by crane lift the pump/motor skid properly and carefully set it on the leveling plate. Note: All lifting activity shall comply to Lifting Safety Procedure 0-WD010-MZ711-10015 and Rigging and Slinging Procedure 0-WD010-MZ711-10024 b. Conduct elevation check and centerline alignment of the pump skid based on the markings and the bench marks. Note: Skid Centering ± 3mm c. Once the skid is centered, the anchor boxes are then grouted. d. After curing of the anchor bolt grout, conduct the final anchor bolt tightening. e. After the anchor bolt tightening, preliminary coupling alignment shall be done. Note: Radial: ± 0.05mm at 90° and 270° ± 0.10mm at 180° Face: ± 0.05mm at 90° and 270° ± 0.05mm at 180° Bolt tightening should be following the supplier recommendation Note: Coupling alignment work is not applicable to closed coupling type (Single Shaft Connection) PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT 7.4 DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 14 OF 31 Installation Works of Vertical Pump a) For installation of horizontal pump, tailing lift method is necessary. Using two cranes, one for main lift and the other for tailing, lift the vertical pump and install it to the pump barrel. Check again elevation and alignment of the pump. Note: All lifting activity shall comply to Lifting Safety Procedure 0WD010-MZ711-10015 and Rigging and Slinging Procedure 0WD010-MZ711-10024 b) Once confirm the reading is acceptable. Tighten the pump to barrel bolts properly and prepare for full grouting. c) By crane lift the motor and install on the vertical pump head. d) Preliminary coupling alignment to be done prior to start the installation of suction and discharge piping. Note: Radial: ± 0.05mm at 90° and 270° ± 0.10mm at 180° Face: ± 0.05mm at 90° and 270° ± 0.05mm at 180° Bolt tightening should be following the supplier recommendation 7.5 Final Alignment Inspection a) After the piping connection is completed, final coupling alignment shall be done and witnessed by the QC Engineer and should be properly documented. Note: Radial: ± 0.05mm at 90° and 270° ± 0.10mm at 180° Face: ± 0.05mm at 90° and 270° ± 0.05mm at 180° Supplier’s recommended tolerance shall be prioritized if vary. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT 7.6 DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 15 OF 31 Working on Extended Hours In case of required to work on extended hours (Night Work), the work area lighting shall comply to the HSE Management Plan, Section B-24-4-3 Work Area Illumination (0-WD010-MZ71110001) 7.7 Working in Confined Space In case of required to work inside confined space area, the work shall comply to the HSE Management Plan, Section B-4 Confined Space (0-WD010-MZ711-10001) 8.0 QUALITY ASSURANCE & QUALITY CONTROL (QAQC). The activities shall be conducted in accordance to the Project Specification, requirement and Code of Standard. All testing and inspection requirement shall be referred to the Field Inspection Test Plan (FITP) 0-WDxxx-xxxxx-xxxxx Field Inspection Test Plan for Rotating Equipment. 9.0 SAFETY, HEALTH & ENVIRONMENTAL REQUIREMENTS 9.1 Site Safety and Health Requirements Construction team shall be responsible to ensure that all the safety controls are in place as per work activity’s HIRARC and MSRA; and should empowered to stop work to rectify any unsafe condition or act. The HSE team is responsible to enforcement of this expectation and the construction team to be responsible for the implementation thereof. Safety procedures will be applied and controlled full time by experienced site supervisor and site safety supervisor. All equipment shall be inspected and tested on a regular schedule by qualified/competent personnel. Maintenance supervisor shall check and record all relevant documents for reference. All safety activities and result of inspection will be reported to Project Manager. Prior to start work, daily Tool Box Meeting shall be held & Risk Assessment of daily work to be briefed. HSE Team will regularly inspect all areas and take all required action to ensure the works do not cause risk to the health, safety of personnel and environmental matter. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 16 OF 31 All equipment shall be jointly examined by company prior to admission to site and if suitable for use on site a sticker will be applied to the item of equipment. To prevent any vehicle accidents caused by entry and exit at the main access road gate, warning sign board will be erected on both side of road. Signal man will be arranged when anticipated vehicle passage increase. Detail plan and procedure for safety assurance will be implemented according to the Site Safety and Health Plan and Emergency Response Plan. When required, the barricades are established for limited access/ The type of barricades is the warning tape and poles to increase the awareness of surrounding parties. As per the HSE Management Plan (0-WD010-MZ711-10001), where PPE is required, personnel must wear as minimum: Safety-toed footgear in compliance with the CE standard/ DOSH-SIRIM MS Standard Hard hats in compliance with the CE standard/ DOSH-SIRIM MS Standard Safety glasses with side shields in compliance with the CE standard/ DOSH- SIRIM MS Standard Adequate coveralls. Where there is a fire hazard, coveralls will be worn and be fire retardant. Luminescent work vests. 9.2 Environmental Requirements The HSE Manager Shall be responsible for monitoring of the implementation of the Environmental and Waste Management Protection Procedure (0-WD010-MZ711-10018 & 10019) On the project. Review and update the procedure if necessary. Shall appoint a competent Environmental Officer that appropriately certified by DOE. The environmental officer will be responsible for the implementation and monitoring of the environmental impact according to the environmental protection procedure and conditions by DOE. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 17 OF 31 The construction activity shall comply with relevant construction requirements and local environmental legislation. All construction works are to be carried out in such a way so as to minimize disturbance to the environment. Construction work shall be carried out in such a manner that there is no damage to or interference with the following (other than to the extent that is necessary for them to be removed or diverted to permit the execution of the works within the defined operational perimeter): • Natural and man-made drainage systems; • Public utilities; • Structures, roads, or other property; and • Public and private vehicular and pedestrian access. The construction activities will be carried out / staged in a way as to minimize exposure / interruptions (e.g. noise, air emissions to surrounding communities and reduce the potential for environmental impacts. The construction team will maintain and clean all working areas and temporary buildings on a regular basis and shall at all times keep access to work sites free of all debris, waste and excavated material and other obstructions. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 18 OF 31 9.3 ASSEMBLY POINT In case of emergency, evacuate and move towards to the nearest assembly point for head count section and wait for further instruction. 9.4 EMERGENCY CONTACT Contact Person MALAYSIA EMERGENCY RESPONSE Phone No 999 SERVICE PEC POWERCON HSE MANAGER PEC POWERCON SAFETY & HEALTH 019-3962947 016-2042205 OFFICER PEC POWERCON ENVIRONMENTAL ENGINEER 019-3708226 PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 19 OF 31 9.5 WELFARE AND FIRST AID Rest room First aid box Drinking Water Sanitary facilities Note: Sanitary facilities to be cleaned and sanitized at least twice a day 9.6 COVID-19 SAEFTY MEASURE 9.6.1 MANDATORY SAFETY MEASURE Mandatory wearing of masks in public places and workplaces. Availability of hand washing/sanitizing stations in frequented places and high-touch areas. Mandatory physical and social distancing at 1 to 2 meters between individuals. Procurement of Covid-19 testing kits, PPEs, etc. Contact-tracing systems in place. Placement of relevant signage and on-line information materials. Implementation, monitoring and maintenance of planned schedule for workers traveling to and from respective workplaces, including chartering of transport services. Implementation of measures dealing with workers confirmed positive for Covid-19 by authorized testing/medical facilities. Establishment of “Workforce and Workplace Management Plan”, showing also information on number of employees, working hours, workplace condition/office floor areas, etc. Provision for Isolation Room for big identified establishments separated from the company clinic and separate bin for infectious materials. PULAU INDAH COMBINED CYCLE POWER PLANT METHOD STATEMENT FOR INSTALLATION OF ROTATING EQUIPMENT DOC. No: 0-WD000-CM620-10002 REV. : C PAGE : 20 OF 31 9.6.2 INSIDE WORK PLACE SAFETY MEASURE Use face masks at all times. Use of gloves, face shield encouraged. Putting plastic or Plexiglas shields for front line service desks and between desks that face each other. Physical distancing at all times. Taping off areas not to be used to allow social distancing. Patrol of project site for the Day to ensure compliance. Doors kept partly open to prevent need to handle door knobs. Disinfection of frequently handled objects (door knobs, phones) and common areas (kitchen, conference rooms) every 2 hours or after every use, when applicable. Limit number of people who use elevators or man-lifting facilities. Providing sanitizers in corridors, conference areas and other common areas. Providing clean water, no-touch soap dispensers, sanitizers, and hand dryer in washrooms and toilets. No rolled tissues. No eating in communal areas. Workers to eat in their individual work areas. No gathering of more than 6 (six) people in one room. No lending of office/ personal items and tools. If needed, disinfect items before and after transfer. Display of COVID prevention infographics. Providing separate bin for hazardous waste like masks, gloves, etc. 10.0 HAZARD IDENTIFICATION, RISK ASSESSMENT & CONTROL HIRARC (Hazard Identification, Risk Assessment and Risk Control) will be implemented prior to any activity. HIRARC is detailed in appropriate safe work instructions or job specific, job safety & environmental analysis. Hazards will vary as the location and all personnel undertaking the works shall be made aware of particular location hazards. Daily Equipment Inspection will be conducted and recorded after morning Tool box meting (TBM). Daily start up meetings will be conducted and documented by supervisors to ensure all safety measures are in place for the day’s activities. Refer PIPP-HIRARC-EESB- 05 Rev. 0 for Risk Assessment details. APPENDIX 1 HIRARC FORM Severity (S) Catastrophic Fatal TABLE 1- Consequence (Severity) Rating Guidance Risk Description Action Example 15 - 25 High (H) 5 - 12 Medium (M) 1–4 Low (L) A HIGH risk requires immediate action to control the hazard as detailed in the hierarchy of control. Actions taken must be documented on the risk assessment form including the date for completion. A MEDIUM risk requires a planned approach to controlling the hazard and applying temporary measures if required. Actions taken must be documented on the risk assessment form including the date for completion A risk identified as LOW may be considered as acceptable and further reduction may not be necessary. Numerous fatalities, irrecoverable property damage and productivity Rating 5 Approximately one single fatality major property damage if hazard is realized 4 Serious Non-fatal injury, permanent disability 3 Minor Disabling but not permanent injury 2 Minor abrasions, bruises, cuts, first-aid type injury 1 1 Negligible TABLE 2- Likelihood Rating Guidance Description Likelihood (L) Most likely Possible Conceivable Remote Inconceivable Example Rating The most likely result of the hazard/event being realized 5 Has a good chance of occurring and is not unusual 4 It might be occurring at some time in future 3 Has not been known to occur after many years 2 Is practically impossible and has never occurred 1 TABLE 3- Risk Matrix Severity Likelihood 1 2 3 4 5 5 5 10 15 20 25 4 4 8 12 16 20 3 3 6 9 12 15 2 2 4 6 8 10 1 1 2 3 4 5 DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 23 OF 31 PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL PULAU INDAH COMBINED CYCLE POWER PLANT HIRARC FORM HIRARC Title: ROTATING EQUIPMENT INSTALLATION HIRARC Ref. No. Date PIPP-HIRARC-EESB-05 Rev. A 26-01-2022 (Psychosocial) - Poor Communication • Stop Work • Delay of PTW approval from POSCO • NO VALID PTW, NO WORK • Read and understand PTW content before commencing any work 2 • Conduct pre-task toolbox and brief work scope, communicate the hazards and control measure (Psychosocial) - Untrained workers, • Personal Injury • Damaged to equipment • Loss of property • Deployment of competent and skilled workers as per statutory and project requirement. • All workers must possess a valid 3 CIDB card and attend POSCO site safety induction training. • Mandatory PPE must always be worn i.e., safety helmet, vest, safety glass, and safety shoes. • Conduct pre-task toolbox and brief work scope, communicate the hazard and control measure. • To performed covid-19 RTK-Ag/RTPCR before entering to site • Compliance of SOP e.g. use of 3ply face mask, use of hand sanitizer and sanitizing work, social distancing, to avoid crowded and gathering. PEC HOD RISK CONTROL Severity (S) Preparation: Mobilization of workforce EFFECT EXISTING CONTROL MEASURE (If any) Approved by: PEC HSE RISK ANALYSIS Probability (p) Permit to Work Application HAZARDS Reviewed by: ENGINEER HAZARD IDENTIFICATION JOB SEQUENCE Prepared by: Zafran Zaharol 2 2 Risk Rating (P*S) Score 4 6 Level (L) (M) RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Closed monitoring from the engineer supervisor ensuring the permit applied for each activity • Site inspection on PTW from the safety department • Engineer/ Supervisor/ Safety • Every worker should be checking accordingly their competency and designation by safety and HR department prior to hiring. • Continues training should be given to the workers to • To ensure training of COVID19 management given to the staff and workers. • Human Resource/ Safety/ Engineer/ Supervisor PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION EFFECT • Physical Injury Mobilization of (Mechanical) - Collision with moving • Property equipment & damage objects materials Traffic movements (deliveries etc.) (Physical) - Uncontrolled or unexpected movement of machinery, components, work pieces, vehicles, or loads -Pinch Point (Ergonomic) • Overexertion due to manual handling • PTW shall be applied as required • POSCO must inspect all types of machinery/equipment 3 • The operator must have full attention and not be allowed to use a cell phone or walkie-talkie • Banksman shall be present at the site to direct the traffic. • Keep all other works clear of operating machinery / Vehicle • Driver / Operator is not allowed to use an earphone. • Verify the soil condition (access) before entering the vehicle to the site • Place vehicle at a designated location • Use Wheel stopper • Adhere to laydown area speed limit 25km/h • Securing of tools/materials during transportation • Vehicle routes kept free of obstructions (with spillages being cleaned up promptly • Parking of cars and vans is only allowed in marked spaces, well away from external • Any reversing that is necessary should be overseen by a trained reversing (banksman). RISK CONTROL Severity (S) HAZARDS EXISTING CONTROL MEASURE (If any) Probability (p) JOB SEQUENCE RISK ANALYSIS DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 24 OF 31 2 Risk Rating (P*S) Score 6 Level (M) RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Barricade of loading/unloading activity area to prevent any unauthorized entrance • Person in charge supervision should be on the working place • Drivers to follow directions of the signalman. Driver or operator must be inducted before entering the worksite • Material and transportation supervisor PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION Risk Rating Severity (S) Loading and unloading materials (Crane / Forklift / Manual Handling) EXISTING CONTROL MEASURE (If any) RISK CONTROL Probability (p) JOB SEQUENCE RISK ANALYSIS Score (Ergonomic) • Utilize mechanical lifting aids or equipment • Providing personal protective equipment, e.g., non-slip gloves and footwear 3 2 6 (Physical) • Physical Injury • Twisting, turning, • Property grabbing, picking, damage or wringing actions with fingers, hands, or arms (Physical) Failure or collapse or overturning of crane, winch, hoist, excavator, or other appliance used in raising or lowering persons or goods, or parts thereof (Physical) • Trips/falls due to uneven/ slippery surfaces • Appropriate PPE mainly and gloves must be provided to the workers. • Use mechanical equipment such as wheelbarrow/trolley or other similar equipment. • Workers handling sharp edges require to use cut resistance hand gloves to prevent hand injury. • Ascertain work area and ensure that ground surface is free from tripping hazards. All materials are to be kept tidy. • Suspend lifting work during strong wind, heavy rain, or lightning. 2 3 6 HAZARDS EFFECT • Back Injuries • Overexertion due • Muscular to manual handling injury (Physical) Working in exposed lightning, bad weather, and vital wind area DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 25 OF 31 (P*S) Level (M) (M) RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Reduce the load risk by using lighter weights or more stable containers • Ensure appropriate rest break, job rotation, and training is involved • Material and transportation supervisor • . Ensure workers are in fit health • Material/ condition to perform the task. transportation/ • Barricade the working Area and displa Crane warning signs Operator and • Standby personnel must be on standb lifting to control and prevent unauthorized supervisor entry to the working area. • Visible inspection of the ladder before use. • Close supervision by work supervisor • Plan the unloading area • To protect or remove the sharp edges before working • Proper housekeeping is to be done all the times • Operator crane to check the wind speed at crane anemometer before lifting activity during the windy time. • Provide lightning detector PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION Foundation survey, centerline, marking, chipping (Physical) • Trips/falls due to uneven/ slippery surfaces (Physical) • Contact with rough concrete surface Erection of vertical and horizontal type pump (Physical) • • • • • Working at height Falling objects Overloading Tripping Pinch Point EFFECT • Back Injuries • Muscular injury • Physical Injuries • Physical Injury • Muscular Injury Risk Rating Severity (S) HAZARDS EXISTING CONTROL MEASURE (If any) RISK CONTROL Probability (p) JOB SEQUENCE RISK ANALYSIS DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 26 OF 31 Score 3 2 6 (M) • Pre-start talk must before be starting • , Site of the activity Engineer • Only trained workers to execute the • Supervisor task • Supervisor to have close monitor while the task being performed To ensure work area being barricade and signage display to notify others 3 2 6 (M) • Pre-start talk must before be starting • Supervisor, of the activity Foreman, Site • Only trained workers to execute the Engineer task • Supervisor to have close monitor while the task being performed • To ensure work area being barricade and signage display to notify others • Cable stand to be used and must be higher from head to avoid cable from laying on the ground. • Blocking materials at access way to be keep/arrange properly. • Opening at platform to be hard barricade or cover temporary using metal deck. • Uneven floor/grating to be put signage and marking using adhesive floor tape • Ensure the workers are brief regarding pinch point hazard and effect of the hazard during toolbox meeting. • For working at height to install lifeline/railing using scaffolding pipe as anchorage for the harness lanyard • Wear proper hand gloves while marking on the foundation • Wear proper safety glass • Ensure use of proper hand gloves • Ensure use of PPE • Cover opening with plate/ barricade the opening with scaffolding. • Provision of signage at the location of the holes. • Highlight hazard during toolbox meeting • opening area to hard barricade • Ensure PTW is in place • Ensure proper working platform with complete fall protection • Ensure full-body harness and 100% Tie-off • Ensure the scaffold platform is erected correctly with the "Safe to use "tag. • Hand tools and the loose item must be secured with wire, rope as lanyard to the anchorage to prevent fall from height • Works materials strictly not allowed to be stored on the platform except for working tools • Ensure avoid overreaching and climbing on the handrail. • Ensure the unauthorized person is not allowed to modify the scaffolding, and if needed, changes must be modified by a trained and certified scaffolder. • Ensure safe access to the working platform • Scaffold access must be free from (P*S) Level RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL obstruction • Ensure sufficient illumination in the work area machine to avoid finger injury. • special care of body and eye protection with • Must clean the debris after completing the job and maintain good housekeeping. • Proper PPE to be used to protect the hand from getting direct hit by tools (such as a hammer) • ensure hands are away from pinch point • Lifting work to be performed by competent rigger and crane operator • Crane obtain safe to use sticker verify by POSCO Use of power tools such as Grinder 4’/ 9’/ Cutter & Drill machine (Electrical) • Damaged socket & Cable insulation. (Physical) • Slip/Trip • Noise • Vibration (Environmental) • Dust • Electrocution • Physical Injury • Loss Hearing Ill Health • All portable electrical must be Inspected, color-coded, and verified by POSCO safe to use. Makes sure the test dates are visible on equipment. • Ensure all grinding/cutting wheels shall be appropriate • Ensure all power tools are in good condition and appropriately maintained • PTW to be obtained before commencing the task. • To ensure no use of damaged industrial sockets and power cables. • Ensure cables from power tools shall be organized as not to present a tripping hazard • Only trained competent person operatives to operate the power tools. • Ensure proper and regular maintenance of equipment that takes account of noise. • Ensure proper hearing protection always DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 27 OF 31 • All workers required to attend and complete the WAH training by POSCO prior working at height at site • For working at height more than 1.8 meter required to use full body harness with double lanyard and 100% tied off • To ensure all working platform inspected and safe to use by scaffolding inspector • To install working platform complete with guardrail, toe board and lifeline for fall protection. . 1 4 4 (L) • Supervisor, Foreman, Site Engineer PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 28 OF 31 • Ensure the workers use the right tools and are trained to use them correctly. Ensure defective tools that require maintenance is reported for repair or replacement HAZARD IDENTIFICATION (Physical) • Falling from height • Trips/falls due to uneven/ slippery surfaces • Hit by falling objects from height • Pinch Point Working under suspended load (platform installation) EFFECT • Physical injury • • • • • • • • Severity (S) Bolt tightening HAZARDS EXISTING CONTROL MEASURE (If any) RISK CONTROL Risk Rating Probability (p) JOB SEQUENCE RISK ANALYSIS Score 1 4 4 Provide safe working platform Training for worker / staff WAH, lifeline approved, All tools must be secured Work zone to be barricaded with warning sign Wear full body harness with double lanyard and shall 100% tied-off Install hard barricade at the edge of the floor opening Proper PPE to be use to protect hand from get direct hit by tools (such as hammer) ensure hands are away from pinch point Ensure the area are barricaded at ground level. (P*S) Level (L) RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Pre-start talk must be done before • Supervisor, start of the activity Foreman, • Only trained workers to execute the Site task Engineer • Supervisor to have close monitor while the task being performed To ensure work area being barricade and signage display to notify others PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION (Electrical) • Damaged socket & Cable insulation. (Physical) • Slip/Trip • Noise • Vibration • Contact with hot surface (Environmental) • Dust EFFECT • Electrocution • Physical Injury • Loss Hearing • Ill Health • All portable electrical must be Inspected, color-coded, and verified by POSCO safe to use. Makes sure the test dates are visible on equipment. • Ensure all grinding/cutting wheels shall be appropriate • Ensure all power tools are in good condition and appropriately maintained • PTW to be obtained before commencing the task. • To ensure no use of damaged industrial sockets and power cables. • Ensure cables from power tools shall be organized as not to present a tripping hazard • Only trained competent person operatives to operate the power tools. • Ensure proper and regular maintenance of equipment that takes account of noise. • Ensure proper hearing protection always • Ensure the workers use the right tools and are trained to use them correctly. • Ensure defective tools that require maintenance is reported for repair or replacement Risk Rating Severity (S) Hot Work Welding, Grinding & Cutting Drilling HAZARDS EXISTING CONTROL MEASURE (If any) RISK CONTROL Probability (p) JOB SEQUENCE RISK ANALYSIS DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 29 OF 31 Score 3 2 6 (P*S) Level (M) RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Pre-start talk must be done before • Supervisor, start of the activity Foreman, Site • Only trained workers to execute the Engineer task • Supervisor to have close monitor while the task being performed To ensure work area being barricade and signage display to notify others • Fire extinguisher to be place standby near to the hot works area. Trained fire watcher to be place to monitor the hot work activity. PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION EFFECT (Physical) • strain which can • Lack of lead to illumination or poor fatigue, illumination headaches, • Falling from height burnout and anxiety • Physical (Psychosocial) injury • Lack of psychological support • Apply PTW for the extended night works before work starts. • Shall sufficient lighting have provided for work area • Reflective clothing must be worn while working at night • provide proper access/egress • apply buddy system for working at night • All the spotlight shall function before starting the night works • Apply PTW for the extended night works before work starts. • Shall sufficient lighting have provided for work area • Reflective clothing must be worn while working at night • provide proper access/egress • apply buddy system for working at night • All the spotlight shall function before starting the night works • Sufficient illumination. • To assign buddies system for observing the group • Opening area to be hard barricaded. • To monitored the fatigue management to avoid over working hours and shift. RISK CONTROL Severity (S) Extended working hours or Night work HAZARDS EXISTING CONTROL MEASURE (If any) Probability (p) JOB SEQUENCE RISK ANALYSIS DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 30 OF 31 Risk Rating (P*S) Score Level RECOMMENDED CONTROL MEASURE RESPONSIBLE PERSON (PIC) • Ensure the workers must fit • Supervisor, doing the work Foreman, and • Closed supervision from the person in Engineer charge person for working at night • 2 2 4 (L) PULAU INDAH COMBINED CYCLE POWER PLANT HAZARD IDENTIFICATION RISK ASSESSMEN RISK CONTROL HAZARD IDENTIFICATION EFFECT (Mechanical) • Physical Injury • Twisting, turning, • Muscular grabbing, picking, Injury or wringing actions with fingers, hands, or arms. (Ergonomic) • Overexertion due to manual handling • Utilize mechanical lifting aids or equipment • Providing personal protective equipmen e.g., non-slip gloves and footwear • Wear suitable work gloves appropriate to the task. • Keep hand clear of load before lifting 2 • Pinch point topic to be highlighted in toolbox talk • Use the buddy system with the help of friends • Proper body posture for lifting manual handling • Proper waste disposal method RISK CONTROL Severity (S) Housekeeping & Waste Disposal HAZARDS EXISTING CONTROL MEASURE (If any) Probability (p) JOB SEQUENCE RISK ANALYSIS DOC. No. : PIPP-HIRARC-EESB-05 REV. :A REV. DATE: 26TH Jan 2022 PAGE : 31 OF 31 Risk Rating (P*S) Score Level RECOMMENDED CONTROL MEASURE • Ensure the workers must fit doing the work • Proper segregation of food waste, plastic, metal, construction, and scheduled waste. 2 4 (L) RESPONSIBLE PERSON (PIC) • Supervisor, Foreman, and Engineer