Uploaded by Anwertv Tvbox

ESP Design – Hand Calculations - Production Technology

advertisement
Production Technology
 MENU
ESP Design – Hand Calculations
By Islam Fetoui ||9 Step Design Procedure
Like
This article walks through the suggested nine step procedure for selecting and designing an electric submersible pump.
This nine step procedure for ESP design is a basic hand-design of simple water and light crude oil. For more
complicated well conditions, such as high GOR, viscous oil, high-temperature wells, etc. a number of computer
programs are available to automate this process.
Step 1: Basic Data:
As detailed in the article “Step 1: Basic data ”, step 1 of the nine step design procedure is the most important step
because all the others design steps will depend on the basic data selected in this step.
In this example, a high water cut well is considered. This is the simplest type of well for sizing submersible equipment.
Well Profile:
Privacy - Terms
Vertical Well
Casing: 7” 26#
Tubing: 3 ½” 9,2# N80 NU
Top perforation: 2003m
Pump Intake depth: 1713m
Fluid properties and well conditions:
PVT data non-available
Oil Gravity: 35 API
Water Cut: 90%
Water Gravity: 1,01 rel-H2O
Gas Gravity: 0,8 rel-air
Producing GOR: 200 scf/stb
Bubble Pressure: 964 psi
Bottomhole Temperature: 90 °C
Wellhead Temperature: 50 °C
Wellhead Pressure: 87 psi
Casing-Head Pressure: 15 psi
Inflow performance:
Present production rate: 2500 bfpd @ Pump Intake Pressure = 1160 psi
Reservoir Pressure: 2320.6 psi
Datum point: 2003m (top perforation).
Pump Intake Pressure: 1160 psi
Desired production rate: 3500 bfpd.
Power sources:
Available primary voltage: 418 V
Desired frequency range: 40Hz – 65Hz
Possible problems?
No sand production, no scale deposit
No gas impurities (N2, H2S and Co2).
MF1 experienced frequent starts and stops.
Step 2: Production Capacity:
The theory behind the production capacity calculations was detailed in the post ” ESP design – Step 2: Production
Capacity “. It consists on predicting the well inflow performance.
The pump intake pressure (1160 psi) is greater than bubble point pressure (964 psi). So that, the Productivity Index (PI)
inflow performance method will most probably give satisfactory results.
PI=Q/(Pr-Pwf)
Firstly, we need to calculate the flowing bottomhole pressure (Pwf). Pwf is calculated from the pump intake pressure
(PIP), hydrostatic pressure and friction loss in the casing annulus between the pump setting depth and the datum
point. In the given example, as the pump is set 290m above the perforations, the friction loss, because of flow of fluid
through the annulus from perforations to pump setting depth, is small, as compared to the flowing pressure, and can
be neglected.
Pwf is calculated from the pump intake pressure (PIP), hydrostatic pressure and friction loss in the casing
annulus between the pump setting depth and the datum point. In the given example, as the pump is set 290m above
the perforations, the friction loss, because of flow of fluid through the annulus from perforations to pump setting
depth, is small, as compared to the flowing pressure, and can be neglected.
Therefore:
Pwf = PIP + hydrostatic pressure from pump intake depth to the datum.
Pwf = PIP + 0.433×SG×(2003-1703)×3.28
Because there is both water and oil in the produced fluids, it is necessary to calculate a composite SG of the produced
fluids. SG is calculated from oil SG and water SG.
SG(oil) = 141.5 / (°API+131.5) = 141.5 / (35+131.5) = 0.845.
SG(oil) = 0.845
Water Gravity = 1.01.
WC= 90%
SG= 0.9×1.01+(1-0.9)×0.845= 0.9935
SG = 0.9935
Therefore, Pwf= 1160+0.433×0.9935×(2003-1703)×3.28= 1569.8 psi
Pwf = 1569.8 psi.
Thus, PI = 2500/(2320.6-1563.8)=3.33 bpd/psi.
PI = 3.33 bpd/psi.
Let’s calculate, the Pwf at the desired production rate:
From the Productivity Index equation, Pwf = Pr – Q/PI = 2320.6 – 3500/3.33 = 1269.5 psi.
Pwf = 1269.5 psi
And PIP = 1269.5 – (1569.8-1160) = 860 psi.
PIP = 860 psi.
At a liquid rate of 3500 bfpd, the PIP is a bit smaller than the bubble point pressure (964 psi). Therefore, the
Productivity Index (PI) inflow performance method will most probably give satisfactory results.
Step 3: Gas Calculations:
It is essential to determine the percentage of free gas by volume at the pumping conditions in order to select the proper
pump and gas handling device (if required). All equations used in this section were detailed in the post “ESP design –
Step 3: Gas Calculations”.
In this third step, one must determine The total fluid volume (Vt) of oil, water, and gas at the pump intake. For this
example, Standing’s correlation was used (Standing is the oldest, simplest and most commonly used correlation).
Solution GOR calculation:
Where:
Rs: Solution gas-oil ratio (scf/stb)
API: Oil API gravity
SGg: Gas specific gravity (relative to air)
P: Pressure (psia)
T: Temperature (°F)
To determine the solution GOR (Rs) at the pump-intake pressure, we need to substitute the pump-intake pressure for
the pressure (P) in Standing’s equation. For this example, motor temperature is 70 °C (158 °F).
Rs = 0.8 × [ (860 × 10^(0.0125×35)) / (18 × 10^(0.00091 × 158) ]^1.20482
Rs = 190.3 scf/stb
Oil Formation Volume Factor (Bo):
The oil formation volume factor is defined as the ratio of the volume of oil (plus the gas in solution) at any specified
temperature and pressure to the volume of oil at standard conditions.
Using the following Standing’s equation, determine the oil formation volume factor (Bo):
Bo = 0.972 + 0.000147 × [190.3 × (0.8/0.845)^0.5 + 1.25 × 158]^1.175
Bo = 1.131 bbl/stb @ 860 psi pump intake pressure.
Gas Formation Volume Factor (B ):
g
Bg the volume, in barrels, that one thousand Standard. cubic feet of gas would occupy at some specific pressure and
temperature. It indicates how much the gas volumetrically compresses when taken from Standard conditions (60 ºF, 1
atm) to any other specific conditions.
By assuming 0.85 Z factor, Determine the gas volume factor (Bg):
Bg = 5.05 × 0.85 × (158 + 460) ] / (860)
Bg = 3.085 bbl/Mscf @ 860 psi pump intake pressure.
Now, these three variables: Rs, Bo, and Bg are known. So that, the volumes of oil, water, and free gas can be
determined and percentages of each calculated.
Total Gas Volume:
The total volume of gas (both free and in solution) can be determined as:
Total Gas Volume = (producing GOR x Oil rate)
[Oil rate]: stock tank barrels per day.
Total Gas = 200 × 3500 × (1-0.9) = 70000 scf = 70 Mscf
Total Gas Volume = 70 Mscf
Solution Gas Volume:
Using the solution GOR (Rs) at the pump intake, determine the solution gas volume:
Solution Gas Volume = (Solution GOR @ PIP x Oil rate) = (Rs x Oil rate)
Solution Gas Volume = 190.3 × 3500 × (1-0.9) = 66710 scf = 66.71 Mscf
Solution Gas Volume = 66.71 Mscf
Free Gas Volume:
The free gas equals the total gas minus the solution gas. The difference represents the volume of free gas released
from solution by the decrease in pressure from bubble point pressure of 964 psi to the pump-intake pressure of 860
psi.
Free Gas Volume = Total Gas Volume – Solution Gas Volume
Free Gas Volume = 70 – 66.7 = 3.29 Mscf
Free Gas Volume = 3.29 Mscf
Volume of oil at the pump intake (Vo):
The volume of oil at the pump intake (Vo) equals stock tank barrels times oil formation volume factor (Bo):
Vo = Bo × BOPD
Vo = 1.131 × 3500 × (1-0.9)= 395.9 bopd
Vo = 395.9 bopd
Volume of gas (Vg) at the pump intake:
The volume of gas (Vg) at the pump intake equals the amount of free gas times gas volume factor (Bg):
Vg = Free Gas x Bg
Vg = 3.29 × 3.085 = 10.15 bgpd
Vg = 10.15 bgpd
Volume of water (Vw) at the pump intake:
The volume of water (Vw) at the pump intake is the same as stock tank barrels:
Vw = Total fluid volume x Water Cut
Vw = 3500 × 0.9 = 3150 bwpd
Vw = 3150 bwpd
Total fluid volume (Vt) of oil, water, and gas at the
pump intake:
The total fluid volume (Vt) of oil, water and gas at the pump intake:
Vt = Vo + Vg + Vw
Vt = 395.9 + 10.15 + 3150 = 3556,1 bfpd
Vt = 3556,1 bfpd
Percentage of free gas to total volume of fluids at the
pump intake:
The percentage of free gas to total volume of fluids at the pump intake can now be calculated:
% Free Gas = (Vg / Vt) × 100
% Free Gas = (10.15/3556.1) × 100 = 0.29%
% Free Gas = 0.29%
This is a negligible amount of gas, it is expected that pump performance will not be affected by gas, so no need for a
gas separator (for more details, refer to the post: ” ESP: Pump Intake “).
Composite Specific Gravity (SG)comp:
To determine the composite specific gravity (SG)comp, the total mass of produced fluid (including gas) needs to be
calculated:
The Total Mass of Produced Fluid (TMPF) is:
TMPF = [(BOPD × SGo) + (BWPD × SGw)] × 5.6146 × 62.4 + (GOR × BOPD × SGg × 0.0752)
TMPF = [3500 × (1-0.9) × 0.845) + (3500 × 0.9 × 1.01)] × 5.6146 × 62.4 + (200 × 3500 × (1-0.9) × 0.8 × 0.0752)
TMPF = 1222469,4 lbm/d
The composite specific gravity (SG)comp is:
SGcomp = TMPF /(BFPD × 5.6146 ×62.4)
SGcomp = 1222469,4 / (3500 × 5.6146 ×62.4)
SGcomp = 0.997
Now, we know the total volume of fluid entering the first pump stage (3556,1 bfpd) as well as the composite SG (0.997).
we can continue to the next step of the ESP system design.
Step 4: Total Dynamic Head (TDH):
As detailed in the article “Step 4: Total Dynamic Head”, the total pump head refers to feet (meters) of liquid being
pumped. TDH is calculated to be the sum of: net well lift (the net vertical distance fluid must be lifted from an operating
fluid level in the well), HL; well-tubing friction loss, Ft; and wellhead pressure head, Hwh.
TDH = HL + Ft + Hwh
Net Well Lift Calculation:
HL = Pump Depth – PIP (ft)
PIP( ft) = PIP / (0.433 psi/ft × SGcomp)
PIP (ft) = 860 / (0.433 × 0.997) = 3209.62 ft
NB: Giuseppe’s comment on this article, is to be considered for the subsequent calculation steps below.
HL = Pump Depth – PIP (ft) = 5620.08- 3209.84 = 2410.24 ft
HL = 2859.68 ft
Tubing Friction Loss Calculation (Ft):
Many methods are available to calculate frictional pressure losses. They range from simple empirical equations to
rigorous mechanistic multiphase flow models.
The ESP industry has traditionally used the Hazen-Williams formula to calculate these friction losses (in terms of head,
not pressure).
The Hazen-Williams formula is an empirical equation developed for municipal water distribution systems. It works
reasonably well when water is the flowing medium. However, it should not be used to calculate friction losses in viscous
or gassy fluids.
Hazen-Williams Equation:
F = Friction loss factor (ft/1000ft)
C = Correction Factor (100 for old pipe, 140 for new pipe, 120 for a typical value)
Q = Volumetric flow rate (bbl/d)
ID = Pipe inner diameter (in)
This can be simplified to the following equation:
C = 120
Q = 3556,1 bfpd
ID = 2.992″ (tubing: 3 ½” 9,2# N80)
Pump intake depth = 5620.1 ft (1713m)
F = [15.11 × (Q / C)^1.852] / (ID^4.8655)
F= 38.83 ft /1000ft
Therefore, Ft = 38.83 × (5620.1/1000) = 218.26 ft
Ft = 218.26 ft
Wellhead Pressure Head (H ):
wh
From the input data, the desired wellhead pressure is 87 psi. Calcultate the corresponding head at wellhead using the
composite SG:
Hwh ( ft) = WHP / (0.433 psi/ft × SGcomp)
Hwh ( ft) = 87 / (0.433 × 0.997)
Hwh ( ft) = 279.26 ft
Total Dunamic Head (TDH) Calculation:
TDH = HL + Ft + Hwh
TDH = 2859.68 + 218.26 + 279.26 = 3357.19 ft
TDH = 3357.19 ft
NB: The TDH required is based on normal pumping conditions. If the well is killed with a heavier-gravity fluid, a higher
head is required to pump the fluid out, until the well is stabilized on its normal production. Therefore, more
horsepower is required to lift the heavier kill fluid. This should be considered when selecting the motor rating for the
application.
Step 5: Pump Type:
From the manufacturer’s catalog information, select the pump type which will be operating within the recommended
operating range and with the highest efficiency at the calculated capacity 3556 bfpd (565 m3/d). The expected
production profile of the well has to be covered by the operating range of the pump during the expected ESP run life.
Obviously, the pump ID (series) must fit the 7” 26# casing (ID = 7.276″).
Select the 538 series G31 pump.
NB: When two or more pump types have similar efficiencies at the desired production rate, refer to the post titled “ESP
design – Step 5: Pump Type” to get recommendations on the most adaptable pump to be considered.
Total number of stages required:
From the selected pump performance curve, The head in meters for one stage at 565 m3/d (3556 bfpd) is 8.6 m (28.2
ft). The BHP per stage is 1.875 hp.
To determine the total number of stages required, divide the TDH by the head/stage:
Total number of stages required = TDH/ ( head/stage )
Total number of stages required = (3357.19 /28.1) = 120 stages.
Stages required = 120 stages.
From manufacturer’s information for the Series 538 G31 pump. The housing no. 17 can house a maximum of 117
stages, 124 stages for a housing no. 18.
Either housing no. 17 or 18 should be adequate. In our case, housing no. 18 is selected.
Pump BHP required:
Once the required number of pump stages is decided, calculate the Pump BHP required:
Pump BHP required = BHP/stage × number of stages × SGcomp
Pump BHP required = 1.875 × 124 × 0.997 = 231.8 hp
Pump BHP required = 231.8 hp
Step 6: Optimum Size of Compounds:
The theory behind this step was detailed in the post “ESP design – Step 6: Optimum Size of Compounds”. Actually, ESP
downhole compounds have different sizes and can be assembled in a variety of combinations. These combinations
must be carefully selected to operate the ESP within production requirement, downhole conditions, material strength,
and temperature limits, etc.
Gas Separator / Gas Handler:
As calculated in the “Step 3: Gas Calculations” in this post, the percentage of free gas was negligible (0.29% of the total
volume of fluids at the pump intake). So that, no need for a gas separator.
Seal:
It is preferable to select a Seal series the same as that of the pump and the motor. Otherwise, an adaptor is required to
connect the units together.
From the manufacturer’s catalog, the 513 series GSB3 DB HL (double-bag, high load thrust bearing) [3 chambers,
Bag/Bag/Labyrinth] seal section is selected for this well MF1.
Seal HP required:
The HP required for the seal depends on the TDH produced by the pump and has to be added to the HP required for
the pump. The following Horsepower vs. TDH curve shows a requirement of 2.95 hp for the 513 Series seal operating
against a TDH of 3357.19 ft.
Therefore:
Total HP requirement = Pump BHP requirement + Seal HP requirement
Total HP requirement = 231.8 + 2.95
Total HP requirement = 234.75 hp
Motor:
When selecting a motor, consideration should be given to choosing as large motor as possible for the casing to
optimize the initial cost, motor efficiency, operating cost and ensure better motor cooling (higher fluid velocity).
As mentioned in Step 1: Input Data, MF1 experienced frequent starts and stops. This is why, from the manufacturer’s
catalog, we selected an XP motor which is suggested for wells with frequent starts and stops. Select the 333-hp 562
Series motor from the catalog.
The motor voltage can be selected on the basis of considerations discussed in the post “ESP design – Step 6: Optimum
Size of Compounds”. For this example, (333 hp; 2321 V; 88 amps) seems to be a good choice.
Check the manufacturer’s catalog and equipment information to assure that all operating parameters are well within
their recommended ranges (e.g. shaft HP, housing burst pressure, and fluid velocity).
Typically, the motor is selected to operate in the range from 70 to 100% of its rating. Generally speaking, the maximum
motor load should not exceed 110%, in the other hand selecting a motor with minimum operating load (e.g. 10% or
20%) nullifies the protection monitoring of the motor.
Step 7: Optimum Size of Compounds:
As discussed in the previous post: “ESP design – Step 7: Electric Cables”, Cable selection involves the determination
of Cable Size, Type and Length.
Determine Cable Size:
Available space between tubing collars and casing:
Refer to the manufacturer’s cable catalog to determine if the size selected can be used within the proposed tubing and
casing sizes. Cable diameter plus tubing-collar diameter will need to be less than the inside diameter of the casing. In
our case, all cable sizes can be used.
Conductor voltage drop calculation:
The cable size is selected based on its current carrying capability. Using the motor amps (88) and the following cable
voltage drop chart, select a cable size with a voltage drop of less than 30 volts per 1,000 ft.
Conductor sizes #1 and #2 fall in this category. Cables #1 and #2 have voltage drop of 26 volts/1,000 ft and 20
volt/1000 ft @ 25°C (77°F) respectively. Calculate their voltage drop at the downhole temperature (158°F in our case).
For cables operating at a different temperature, the voltage drop can be determined by multiplying it by Temperature
Correction Factor (TCF) as indicated in the formula below or by using the table below:
TCF = 1 + 0.00214 × (T – 77)
TCF = 1 + 0.00214 × (158 – 77)= 1.173
Therefore:
cable #1 onductor voltage drop @ (T=158°F) = 20 × 1.173 = 23.46 volts/1,000 ft
cable #2 onductor voltage drop @ (T=158°F) = 26 × 1.173 = 30.5 volts/1,000 ft
Operating cost comparison:
I=88A, kWh = 0,05€, cable length= 5720 ft
Size AWG
Resistance
Power
Cost of power loss
Cost of
(ohm/1000 ft)
losses (kW)
(€/month)
power loss
(€/year)
1
0,139
18,47
665
7980
2
0,17
22,59
813
9759
4
0,271
36,01
1296
15557
6
0,431
57,27
2062
24743
The cable #1 is selected for this well.
Cable Type:
As per the input data, the downhole conditions of this well aren’t considered severe (no risk of corrosion, no sour
gases, downhole temperature not high..). So that a standard cable type is selected (with galvanized steel armor).
Refer to the manufacturer’s catalog for more details.
Cable Length:
The pump setting depth is 5620 ft (1713 m). With 100 ft (30.5 m) of cable for surface connections, the total cable length
should be 5720 ft (1743.5 m).
Step 8: Optimum Size of Compounds:
As discussed in the previous post: “Step 8 – Downhole and Surface Accessory Equipment” the required downhole and
surface accessory equipment are described in this step 8.
Downhole Accessory Equipment:
Motor Lead Extension (MLE):
Calculate the length for the MLE:
Pump length = 27.9 ft (8.52 m);
Seal length = 6.3 ft (1.92 m);
Plus 6 ft = 6.0 ft (1.83 m)
= 40.2 ft (12.27 m);
select a standard length of 50 ft (15.24 m) flat cable (AWG: 2, Armor: Galv.).
Cable Bands:
Install three bands per section from the motor pothead to the first splice in the power cable (don’t install bands on a
cable splice). Place a band above and below the splice approximately 4 inches.
The minimum banding recommendation is two bands per tubing joint, with one band in the middle of the joint and the
other band 2 to 3 ft above the collar.
Cross-Coupling Cable Protectors:
Cross-Coupling Cable Protectors are used to protect and support ESP cable. Install a cross-coupling protector every 10
joints.
Check Valve and drain valve:
Select these accessories on the basis of required ODs and type of threads.
Surface Accessory Equipment:
Variable Frequency Drive (VFD):
The motor-controller selection is based on its voltage, amperage, and KVA rating. Therefore, before selecting the
controller, one must first determine the motor controller voltage.
The surface voltage (SV) is the sum of the motor voltage and the total voltage loss in the cable. Taps on the transformer
have to be adjusted to closely achieve this value.
Surface Voltage = Motor Voltage + Conductor Voltage Drop
Surface Voltage = 2321 + [(23.46 Volt/1000 ft × 5720 ft)] = 2455 V.
Surface Voltage = 2455 V.
NB: Surface voltage is less than standard 3 KV cable. 3 kV or higher cable construction can be selected. For this example,
a 4 kV power cable is selected.
The motor amperage is 88 amps; the KVA can now be calculated.
Where:
Vs is the required surface voltage, volts.
A is the motor nameplate current, amps.
KVA = (1.73 × 88 × 2455) / 1000 = 374 KVA
KVA = 374
The 380V motor controller: model: 4500-VT (411 KVA / 624 A) suits these requirements.
Transformers:
The transformer selection is based on the available primary power supply (418 V), the secondary voltage requirement
(2455 V) and the KVA requirement (374 KVA).
The 452 KVA Step-Up transformer (C86554) suits these requirements.
Surface cable:
Select 50 ft (15.2 m) of no. 1 cable for surface connection to transformers.
Step 9: Variable Speed Submersible Pumping
System:
As discussed in the previous post: “Step 9 – Variable Speed Submersible Pumping System”, the most important benefit
of using a VSD is the wide flexibility of the variable frequency ESP system. This permits perfect matching of the lift
capacity of the ESP system and the well’s productivity. Therefore, it operates over a much broader range of capacity,
head, and efficiency.
Since a submersible pump motor is an induction motor, its speed is proportional to the frequency of the electrical
power supply. This relationship between variables involved in pump performance (such as head, flow rate, shaft speed)
and power is known as “Affinity Laws” (also called “Pump Laws”).
According to the affinity laws, the following relationships exist between the actual speed of the centrifugal pump and
its most important performance parameters:
The flow rate of a pump changes directly proportional to its operating speed.
The head developed by the pump changes proportionally to the square of the speed.
The brake horsepower required to drive the pump changes proportionally to the cube of the speed.
The efficiency of the pump does not change with speed changes.
Like
About Islam Fetoui
LinkedIn: https://www.linkedin.com/in/islamfetoui/
View all posts by Islam Fetoui →
« PVT Properties and Correlations
Effect of CO2 on downhole flowrate calculation »
4 Responses to ESP Design – Hand Calculations
Giuseppe Moricca 26 MAY 2018 AT 16 H 05 MIN
Gentlemen,
If I am not wrong, the below Net Well Lift Calculation should be revised, and as consequence the
subsequent other calculation steps.
Net Well Lift Calculation:
HL = Pump Depth – PIP (ft)
PIP( ft) = PIP / (0.433 psi/ft × SGcomp)
PIP (ft) = 860 / (0.433 × 0.997) = 3209.62 ft ????
PIP (ft) =2760.4 ft
HL = Pump Depth – PIP (ft) = 5620.08- 3209.84 = 2410.24 ft
HL = 2859.68 ft ????
The calculation below should be correct.
Net Well Lift (HL ) Calculation
Equations
‒ Head = HT = psi / [(0.433 psi/ft ) x SG]
‒ Net Well Lift HL = Pump Intake Depth (ft) – PIP (ft)
Data
‒ PIP at 3500 bfpd = 860 psi
‒ Pump Intake depth: 5620ft
‒ SGcomp = 0.9935
Calculations
PIP (ft) = 860 / (0.433 × 0.9935) = 1999.14 ft
HL = Pump Intake Depth – PIP (ft) = 5620.08 – 1999.14 = 3621 ft
Net Well Lift (HL ) = 3621 ft
Kind regards,
Giuseppe
gmoricca1949@gmail.com
Reply
admin 26 MAY 2018 AT 19 H 38 MIN
Good catch Giuseppe! many thanks for having pointed it out.
Indeed, for the calculation of the PIP (ft): 860 / (0.433 × 0.997) is equal to 1992ft, not 3209.62 ft!
A comment has been added to the article to consider your comment for the subsequent calculation
steps until the next update of the article.
Kind regards,
Reply
Kelly 30 JUNE 2018 AT 17 H 04 MIN
Hi, may i know why do we need to times with 3.28 while calculating for hydrostatic pressure from pump
intake depth to the datum (0.433 * depth * SG *3.28 )
Reply
admin 2 JULY 2018 AT 11 H 34 MIN
Hi Kelly, This was just to convert meters to feet. The true vertical depth has to be in feet when you use
the following hydrostatic pressure formula: 0.433 * depth * SG.
Hope this helps,
Best regards,
Reply
Leave a Reply
Your email address will not be published. Required fields are marked *
Comment
*
Name *
Email *
Website
ERROR for site owner: Invalid
site key
reCAPTCHA
Privacy - Terms
Post Comment
Follow us on Facebook :
Producti…
3.3K followers
Follow Page
Search
Categories
API & ISO Standards (5)
Artificial Lift (79)
Beam Pump (18)
Equipment & Technology (6)
Fundamental Principles (4)
ESP (48)
9 Step Design Procedure (11)
Application Engineering (5)
Equipment & Technology (30)
Monitoring and Troubleshooting (1)
Gas Lift (5)
Jet Pump (3)
Definitions (1)
Drilling (7)
Flow Assurance (1)
Inflow & Outflow Performance (12)
Petroleum Softwares (1)
Petrophysics (2)
Process Safety Management (1)
PVT (6)
Reservoir Engineering (1)
Well Completion (10)
OK
Well Interventions (2)
Well Integrity (4)
Well Logging (2)
Well Testing (2)
Production Technology | Powered by Mantra & WordPress.
Download