TAMESON Labeling of Explosion Proof Equipment According to ATEX Directives Equipment Group Application I Other Industries Example 1: Definition Complies with European Directive Notified Body Number Specific Marking for Explosion Protection 2: 3: Protection Symbol Zones Type of Protection 1 2 d • • Flameproof enclosure e • • Increased safety • • • • ia i 0 • ib ic ma m • • • • • mc Moulding • • Oil immersion q • • Powder filling nA • Non-sparking nC • Enclosed break nR • Restricted nL • Limited energy px • • py • • Normal Operation M2 Continuously for Long Periods or Frequently Very High Two Faults 1 Occasionally High One Fault 2 Unlikely or Infrequently and for a Short Period Normal Normal Operation 3 Pressurised enclosure Type of Environment Group & Class Mines I IIA Explosive Gases Explosive Dusts IIC III A Flammable fibers B Non-conductive dust C Conductive dust City Gas Acrylic nitrile Ethylene Ethylen oxide Ethyl ether Hydrogen Acetylene • tb tc maD • • • • Protection by enclosure • • • • • • Encapsulation • mbD mcD iaD ibD Type of Protection • • • • icD • Dust Zone 20 Gas Zone 1 Dust Zone 21 Gas Zone 2 Dust Zone 22 Ethyl glycol Carbon hydrogen Carbon disulphide Zone Classification/Equipment Category Equipment Protection Level (EPL) Zone 0/1G Zone 1/2G Ga Gb Zone 2/3G Intrinsic safety • • Zone 0 T6 <85° C • • Gas Attention: this list is only a selection of possible flammable mediums and is not complete! • 22 Dust Acetal-dehyde Op sh 21 Gas Petrol Ethanol Diesel Fuel Cyclohexane Fuel Oil n-Butane n-Hexane • 20 Dust Ammonia Methane Ethane Propane • Zones Gas Temperatures according to coal dust accumulation on equipment (< 150°C for coal mines or < 450°C for not coal mine tunnels) Firedamp Op pr Optical radiation Zone Classification Hazardous Material in the Atmosphere T2 <300° C For dust explosion proof, the max. surface T3 <200° C temperature is directly T4 <135° C shown (e.g. T80°C) T5 <100° C • Explosive Atmosphere Contains Gb II 2G Ex d IIC T6 II 1D Ex ta IIIA T80°C Da Mb I M2 Ex d I • ta pD High • Protection Symbol iD De-energised T1 <450° C Op is mD M1 • pz tD Two Faults IIB • Op Very High Expectancy of the Occurrence of an Explosive Atmosphere II Intrinsic safety o p Remain Functional • mb n Required Performance in the Event of an Explosive Atmosphere Equipment Category Level of Protection Zone 20/1D Zone 21/2D Pressurised enclosure Gc Da Db Zone 22/3D NA/M1 Ma NA/M2 Mb tameson.com | tameson.co.uk | tameson.nl Dc Temperature Class 0158 Mining Equipment Categorized by