Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily Exam : D-PE-OE-23 Title : Dell Technologies PowerEdge Operate 2023 https://www.passcert.com/D-PE-OE-23.html 1/6 Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily 1.A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue? Note: It is necessary to dose (x) the simulator window before you can select a response to this question. A. The Virtual Console is disabled B. Operating system not installed on remote server C. The server has been powered down D. There are more than the maximum number of active sessions Answer: C 2.What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server? A. All GPU cards must be installed at the same time B. All GPU cards must be of the same type but can be a different model C. All GPU cards must be of the same type and model D. All GPU cards must be installed on the same riser card Answer: C 3.What happens when the Hardware Root of Trust fails to validate the BIOS? A. Boot Guard switches over to the backup BIOS and logs a warning in the system event log. B. Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel. C. The server continues running and logs a critical error in the system event log. D. The server shuts down and logs a critical error in the system event log. Answer: D 2/6 Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily 4.A technician receives a new server with five drives. They need to configure the drives based on the following requirements received from the administrator: - Drive 0 as a single disk with no RAID - Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5 The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set. How should the technician configure the drives? A. Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare B. Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare C. Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare D. Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare Answer: B 5.A technician must update the firmware on a savor, but has no network connectivity. What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware? A. OpenManage Server administrator DVD B. ftp dell.com C. NFS share D. USB key with Dell Update Package Answer: A 6.A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback? A. The LCC can be rolled back; the iDRAC cannot be rolled back B. The iDRAC cannot be rolled back and the LCC cannot be rolled back C. The iDRAC can be rolled back; the LCC cannot be rolled back D. Both the iDRAC and the LCC can be rolled back Answer: D 7.A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature. What is required to use this feature? A. OpenManage Mobile App installed on an Android or iOS device B. OpenManage Mobile App installed on a laptop C. Quick Sync enabled bezel D. iDRAC Enterprise license Answer: A 8.Which is responsible for controlling the NVMe disks, when using a Paddle Card in a PowerEdge 15G server? A. S150 B. HBA355 C. H745 Answer: A 3/6 Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily 9.A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency. Which setting can they enable to achieve this? A. Logical Processing B. Performance per Watt (DAPC) C. Adjacent Cache Line Prefetch D. Performance per Watt (OS) Answer: D 10.How can a system administrator compare the currently installed hardware to the original system configuration? A. Pull a SupportAssist Collection Comparison Report B. Restore the original System Profile C. View Factory Shipped Inventory D. Export a Tech Support Report Answer: C 11.A server has six memory modules attached to each CPU Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space. What should the technician install/configure? A. No additional memory Switch on Single Rank Spare Mode B. No additional memory Switch to memory Mirroring C. Six additional memory modules matching the original Switch on Single Rank Spare Mode D. Six additional memory modules matching the original Switch to Memory Mirroring Answer: D 12.Where is the LCD panel located on a Dell PowerEdge 16G server? A. An add-on Server Bezel B. Rear of the server C. Left control panel D. Right control panel Answer: A 13.A technician is trying to troubleshoot a server that constantly keeps raising and lowering the RPMs of the fans. The technician investigates and finds the following: - No errors are displayed - No obvious log entries exist concerning temperatures - Server cover is installed and secured - No expansion cards are installed 4/6 Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily What would be the quickest action plan that the technician could attempt to try to fix the issue with the fans? A. Replace all the fans B. Upload the latest iDRAC firmware C. Replace the fans one at a time until the faulty fan is identified D. Adjust the Multi Vector Cooling values Answer: B 14.A technician installs a PCIe card into a server, but the card does not appear in the OS. The server does not have an LCD to display errors, but a light is flashing on the front of the server. What actions can the technician take to troubleshoot the issue? A. Initiate Hardware Stress Test from iDRAC GUI Check PCIe Bus Log for errors B. Run Hardware Diagnostics from Lifecycle Controller Review the Lifecycle Controller log for errors C. Run Hardware Diagnostics from Lifecycle Controller Initiate Hardware Stress Test from iDRAC GUI D. Review the Lifecycle Controller log for errors Check PCIe Bus Log for errors Answer: B 15.What is the minimum number of components, beside the system board, required to POST? A. 1 PSU, 1 DIMM, and 1 CPU only B. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller C. 1 PSU and 1 CPU only D. PSUs, CPUs, and DIMMs as configured in BIOS Answer: A 16.Which export type in iDRAC restores a Server Configuration Profile to a known baseline? A. Advanced B. Replacement C. Basic D. Clone Answer: B 17.A technician is setting up SNMP Trap Alerts on a 14G servers. After specifying the trap destination address, what should be the next step? A. Enable the SMNP Client service on the iDRAC B. Include the server OS IP address in the destination systems authentication script C. Enable the SMNP services in the server operating system of the sending server D. Send an SNMP trap test to the destination system Answer: D 18.A technician is installing Windows Server 2016 on a server with RAID 1 and RAID 5 virtual disks. 5/6 Download the latest D-PE-OE-23 Dumps To Pass The Exam Easily How should they configure the server and deploy the OS? A. Go to system setup to configure both virtual disks Select the Deploy OS option in the system setup utility B. Go to Settings in the Lifecycle Controller Configure both virtual disks using the guided OS installation method C. Create two virtual disks using the iDRAC UI Access the Lifecycle Controller Go to OS deployment using ‘Deploy OS’ D. Go to the RAID Configuration menu in the Lifecycle Controller Create both virtual disks Go to OS deployment using 'Deploy OS' Answer: C 19.What is the maximum number of CPU cores that can be configured in a Dell EMC PowerEdge R6525 server? A. 56 B. 64 C. 112 D. 128 Answer: D 20.A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR. What action might be required to solve the alert? A. Clear logs B. Update the Intel driver C. Swap the PERC controller D. Reseat the IDSDM Answer: B 21.A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license. Which three steps should the technician take to complete this task? (Choose three.) A. Restart the server and press F10 to start the firmware update process B. After firmware update, run fsck command on the virtual disks C. Obtain the latest firmware update for the RAID controller D. Run racadm fwupdate command from a management station E. Open a command shell and execute the firmware package F. After the firmware update, restart the server Answer: DEF 6/6