OWNER ARCHITECT CIVIL STRUCTURAL MEP EVC-WDG TOWER II, LLC CHORD DESIGN STUDIO, P.C. RIDGETOP ENGINEERING PORTIS STRUCTURAL DESIGN GIVEN & ASSOCIATES 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 1425 MARKET STREET SUITE 220 DENVER, CO 80202 541 E GARDEN DR UNIT N WINDSOR, CO 80550 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 785.272.1398 t: 303.694.2445 t: 970.663.4552 t: 720.501.4900 t: 303.716.1270 STARBUCKS CORE & SHELL DENVER, CO Project Number:19022 COMPOSITE PERMIT SETSET THROUGH 14 27 FEB DEC2020 2019 SHEET INDEX LEGEND 2/17/2020 10:26:30 AM SHEET NUMBER SHEET NAME 01 GENERAL G0 COVER G010 SHEET INDEX G011 GENERAL INFORMATION G012 GENERAL SPECIFICATIONS G013 MATERIAL SPECIFICATIONS G014 MATERIAL SPECIFICATIONS G015 MATERIAL SPECIFICATIONS G016 MATERIAL SPECIFICATIONS G017 MATERIAL SPECIFICATIONS G018 MATERIAL SPECIFICATIONS G019 MATERIAL SPECIFICATIONS G020 MATERIAL SPECIFICATIONS G021 MATERIAL SPECIFICATIONS G031 CODE SUMMARY G201 CODE STUDY PLAN G202 CODE SITE PLAN 02 CIVIL C1 CIVIL COVER SHEET C2 OVERALL SURVEY - GATEWAY CROSSING WEST C3 OVERALL WEST LOTS C4 PARCEL W1A SITE PLAN C5 PARCEL W1A GRADING PLAN C6 PARCEL W1A UTILITY PLAN C7 PARCEL W1A LANDSCAPE PLAN C8 PARCEL W1A DETAIL SHEET C9 PARCEL W1A DETAIL SHEET C10 PARCEL W1A DETAIL SHEET 03 ARCHITECTURE A000 SITE PLAN A001 SITE DETAILS A002 SITE DETAILS A100 FOUNDATION PLAN A101 FLOOR PLAN & ROOF PLAN A151 REFLECTED CEILING PLAN A200 BUILDING PERSPECTIVES A201 BUILDING PERSPECTIVES A202 BUILDING ELEVATIONS A203 BUILDING ELEVATIONS A251 BUILDING SECTIONS A252 BUILDING SECTIONS A301 WALL SECTIONS A302 WALL SECTIONS A501 DOOR AND WINDOW SCHEDULES A601 SECTION DETAILS A602 SECTION DETAILS A603 SECTION DETAILS A604 PLAN DETAILS A605 ROOF DETAILS A606 ROOF DETAILS 04 STRUCTURAL S100 GENERAL NOTES S200 STRUCTURAL PLANS S300 DETAILS 301-320 S301 DETAILS 321-340 S400 DETAILS 401-420 S401 DETAILS 421-440 05 MECHANICAL M001 MECHANICAL SPECS, LEGEND, AND SCHEDULES M101 FIRST AND ROOF FLOOR PLANS MECHANICAL M600 MECHANICAL COM CHECK 06 PLUMBING P001 PLUMBING SPECS, LEGEND, AND SCHEDULES P101 FIRST FLOOR PLUMBING PLANS P102 ROOF PLUMBING PLAN P400 PLUMBING ISOMETRICS P500 PLUMBING DETAILS 07 ELECTRICAL E001 ELECTRICAL SPECS, LEGEND, ONE-LINE E002 ELECTRICAL SITE PLAN E101 FIRST FLOOR ELECTRICAL PLANS E600 ELECTRICAL PANEL SCHEDULES E700 ELECTRICAL ENERGY COMPLIANCE ISSUE 3 - 14 FEB 2020 - PERMIT SET SHEET INDEX ISSUE 2 - 07 FEB 2020 - PERMIT SET SHEET INCLUDED IN ISSUE WITH REVISIONS SHEET INCLUDED IN ISSUE WITHOUT REVISIONS SHEET INCLUDED FOR REFERENCE ONLY SHEET DELETED FROM DOCUMENTS ISSUE 1 - 27 DEC 2019 - PERMIT SET ▲ ● ○ X OWNER EVC-WDG TOWER II, LLC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ▲ 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING ▲ 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 ▲ ▲ MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ● COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 3 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 ● ● ● ● ● Project Number: SHEET INDEX ● ● ● ● ● ▲ G010 19022 DRAWING SYMBOLS MATERIAL SYMBOLS 1. SITEWORK 0 GRID DESIGNATION GENERAL NOTES 2. CONCRETE 1 2 STRUCTURAL GRID 3 EARTH CONCRETE 4 ELEVATION X' - X" LEVEL OR DATUM ELEVATION 5 GRAVEL SAND / GROUT 3. MASONRY CEILING TYPE 6 4. METAL 7 CEILING HEIGHT REFERENCE EL= X' - X" 8 HEIGHT ABOVE FINISH FLOOR BRICK ALUMINUM 9 10 DRAWING NUMBER 11 X XXXX X XXXX BUILDING SECTION REFERENCE CMU STEEL 12 SHEET NUMBER 13 14 15 16 STONE DRAWING NUMBER X XXXX WALL SECTION REFERENCE 5. WOOD 6. THERMAL 17 18 SHEET NUMBER WOOD BLOCKING BATT INSULATION X DRAWING NUMBER SHEET NUMBER XXXX EXTERIOR ELEVATION REFERENCE X DRAWING NUMBER X XXXX SHEET NUMBER X CONTINUOUS WOOD FRAMING BOARD INSULATION FINISH WOOD FIRE SAFING 19 20 21 22 23 24 25 26 27 INTERIOR ELEVATION REFERENCE 28 X PLYWOOD FOAMED-IN-PLACE INSULATION 8. FINISHES DRAWING NUMBER X XXXX 29 30 31 DETAIL SECTION REFERENCE 32 SHEET NUMBER GYPSUM BOARD ALL WORK SHALL COMPLY WITH APPLICABLE FEDERAL, STATE, LOCAL AND ADOPTED CODES, ORDINANCES, REGULATIONS, LAWS, STATUTES, GUIDELINES AND REQUIREMENTS OF BUILDING AND FIRE AUTHORITIES HAVING JURISDICTION. THE GENERAL CONTRACTOR (HEREAFTER "THE CONTRACTOR") AND SUBCONTRACTORS SHALL CAREFULLY STUDY ALL CONTRACT DOCUMENTS AND ACQUIRE A THOROUGH UNDERSTANDING OF THE DESIGN INTENT OF THE PROJECT AND THE DETAILS REQUIRED TO ACHIEVE THE DESIGN INTENT. THE CONTRACTOR SHALL FORWARD REQUESTS FOR CLARIFICATION OR ADDITIONAL INFORMATION WITH REGARD TO ACHIEVING THE DESIGN INTENT OF THE PROJECT TO THE ARCHITECT IN WRITING FOR REVIEW AND WRITTEN RESPONSE. THE CONTRACTOR SHALL CHECK AND VERIFY THE CONTRACT DOCUMENTS WITH FIELD CONDITIONS, CONFIRMING THAT ALL WORK IS BUILDABLE AS SHOWN, PRIOR TO PROCEEDING WITH THE WORK AND VERIFY ALL SPACE DIMENSIONS AS SHOWN WITH EXISTING JOB CONDITIONS BEFORE STARTING CONSTRUCTION. IF DISCREPANCIES EXIST, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING PRIOR TO COMMENCEMENT OF WORK. PRICING OF THESE CONTRACT DOCUMENTS SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE DESIGN INTENT DESCRIBED THEREIN. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS AND SLEEVES THROUGH FLOORS, CEILINGS, ROOFS, WALLS, STRUCTURAL MEMBERS AND ARCHITECTURAL ELEMENTS WITH CIVIL, LANDSCAPE, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND OTHER DISCIPLINES DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS. THE CONTRACTOR SHALL PROTECT ALL IN-PLACE CONSTRUCTION, LANDSCAPING, PAVING, UTILITIES, ETC. FROM DAMAGE DURING CONSTRUCTION. ALL DAMAGED AREAS AND ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION BY THE CONTRACTOR OR SUBCONTRACTOR DAMAGING THE SAME. THE CONTRACTOR SHALL SUBMIT PROPOSED SUBSTITUTIONS OF SPECIFIED MATERIALS/ PRODUCTS TO THE ARCHITECT FOR REVIEW, IN ACCORDANCE WITH PROCEDURES DESCRIBED IN THE SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, CUT-SHEETS, AND SAMPLES WHEN REQUIRED BY THE SPECIFICATIONS, FOR REVIEW BY THE ARCHITECT, PRIOR TO COMMENCING WITH RELATED WORK. ALL WORK SHALL BE ERECTED PLUMB, LEVEL AND TRUE-TO-LINE IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE, MANUFACTURER'S INSTRUCTIONS FOR THE PARTICULAR PRODUCT, AND IN ACCORDANCE WITH THE SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNMENTAL AGENCIES WHEN THERE IS A NEED FOR AN INSPECTION REQUIRED BY THE APPLICABLE CODE, OR BY THE AUTHORITY HAVING JURISDICTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ALL PERSONNEL AND OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE OSHA REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED TO THE OWNER. DO NOT SCALE DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED TO FACE OF GYPSUM BOARD, UNLESS INDICATED OTHERWISE. THE INSIDE FACE OF DOOR JAMBS SHALL BE 4" FROM ADJACENT WALL OR FINISHED COLUMN, UNLESS INDICATED OTHERWISE. WHERE NEW WORK HAS DISTURBED PREVIOUSLY INSTALLED OR EXISTING WORK OR FINISHES, SUCH AREAS SHALL BE REWORKED AND/OR REFINISHED AS REQUIRED TO MATCH THE ORIGINAL CONDITION OF THE AREA PRIOR TO THE DISTURBANCE. EACH MISCELLANEOUS ITEM OF CUTTING, PATCHING OR FITTING IS NOT NECESSARILY INDIVIDUALLY DESCRIBED IN THE DOCUMENTS. THE ABSENCE OF SPECIFIC DESCRIPTIONS OF CUTTING, PATCHING, OR FITTING REQUIRED TO PROPERLY ACCOMMODATE THE SCOPE OF WORK SHALL NOT RELIEVE THE CONTRACTOR OR SUBCONTRACTOR FROM THE RESPONSIBILITY TO PERFORM SUCH WORK AS REQUIRED TO ACHIEVE THE DESIGN INTENT OF THE PROJECT. NOTES APPEAR ON DIFFERENT SHEETS FOR DIFFERENT SYSTEMS AND CONSTRUCTION MATERIAL. ALL SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO ALL RELATED DRAWINGS AND DETAILS. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER AND QUALITY TO THOSE DETAILED. WHERE SPECIFIED DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION, PRIOR TO PROCEEDING WITH WORK. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC ACTION. A FINISH OR FIRE RATING ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL TO BE FINISHED OR FIRE RATED, AS INDICATED. THE HEAD AND BASE CONDITIONS OF ALL FIRE RATED WALLS SHALL BE TERMINATED WITH UL-APPROVED DESIGNS AND MATERIALS. SCOPES OF WORK ON THE DRAWINGS NOTED AS "NIC" ARE" NOT INCLUDED IN CONTRACT. ALL FLOOR ELEVATIONS ARE TO TOP OF STRUCTURAL CONCRETE OR TOPPING SLAB UNLESS INDICATED OTHERWISE. PROVIDE BLOCKING OR OTHER SUPPORT AS REQUIRED FOR ALL WALL, FLOOR, CEILING AND ROOF MOUNTED ITEMS. BLOCKING SHALL BE FIRE RESISTIVE TREATED AS REQUIRED AND PERMITTED BY CODE. SHOULD ANY CONFLICT OCCUR BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ARCHITECT'S CONSULTANTS' DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL, ELECTRICAL, FIRE PROTECTION, EQUIPMENT AND OTHER INSTALLERS. WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND FIELD CONDITIONS, CONSULT THE ARCHITECT PRIOR TO PROCEEDING WITH INSTALLATION. REFER TO PLUMBING DRAWINGS FOR LOCATIONS OF ALL FLOOR DRAINS, TRENCH DRAINS, SUMPS AND SUBSOIL DRAINAGE, UNLESS INDICATED OTHERWISE. IF LOCATIONS CONFLICT WITH ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. ALL PENETRATIONS OF DUCTWORK, CONDUIT, PIPING AND OTHER WORK THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED WITH UL-APPROVED DESIGNS AND MATERIALS TO MAINTAIN THE RATING OF THE ASSEMBLY. ALL EQUIPMENT INSTALLED IN RETURN AIR PLENUMS SHALL BE APPROVED BY THE AUTHORITY HAVING JURISDICTION AGENCY FOR COMPLIANCE WITH CODE. THE CONTRACTOR SHALL COORDINATE ALL EQUIPMENT BASE AND HOUSEKEEPING PADS WITH MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTORS. EQUIPMENT BASE AND HOUSEKEEPING PADS TO BE MINIMUM 4" HIGH AND TO BE INSTALLED BENEATH THE PROJECTED AREA OF THE EQUIPMENT, AND IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. ALL ROOF-TOP EQUIPMENT SHALL BE LOCATED SUCH THAT FALL PROTECTION SYSTEMS ARE NOT REQUIRED FOR EQUIPMENT MAINTENANCE. OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 LOCATION MAP REFERENCE AREA CARPET X XXXX PLAN, SECTION OR ELEVATION DETAIL OR ENLARGEMENT WALL LOCATION TAIL X TOWER ROAD TILE WALL TYPE REFERENCE WALL TYPE NUMBER COPYRIGHT: 2019 DOOR TYPE NUMBER 101 DOOR IDENTIFICATION EQUIPMENT NUMBER 01 EQUIPMENT IDENTIFICATION PROJECT SITE THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. GREEN VALLEY RANCH BLVD # 1 1t WINDOW TYPE NUMBER ROOM NUMBER ROOM NAME 101 1 REVISION NUMBER KEY NOTE NUMBER ? 2 ROOM IDENTIFICATION REVISION NOTE REFERENCE KEY NOTE IDENTIFICATION MATCHLINE SHEET NUMBER GRID LINE 2/17/2020 10:26:31 AM DATE 27 DEC 2019 WINDOW IDENTIFICATION DRAWING NUMBER 1 / A101 DESCRIPTION PERMIT SET ABBREVIATIONS (E) (N) < > @ AC ACT ADJ AFF AFR AL ALT ARCH ASPH B.O. BD BLDG BLK BM BOT BRG C.O. C.O.F. C.O.W. CG CIP CJ CL CLG EXISTING NEW CENTER LINE PLATE AT AIR CONDITIONING ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISH FLOOR ABOVE FINISH ROOF ALUMINUM ALTERNATE ARCHITECT(URAL) ASPHAULT BOTTOM OF BOARD BUILDING BLOCK BEAM BOTTOM BEARING CENTER OF CENTER OF FLUE CENTER OF WALL CORNER GUARD CAST-IN-PLACE CONTROL JOINT CENTERLINE CEILING CLR CMU COL CONC CONST CONT CPT CT DD DIA DJ DS DTL DWG EA EJ EL ELEC ELEV EPS EQ EQUIP ETR EWC EXH F.B.O. F.O. F.O.W FD FEC CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DESIGN DEVELOPMENT DIAMETER DEFLECTION JOINT DOWNSPOUT DETAIL DRAWING EACH EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EXPANDED POLYSTYRENE EQUAL EQUIPMENT EXISTING TO REMAIN ELECTRIC WATER COOLER EXHAUST FURNISHED BY OWNER FACE OF FACE OF WALL FLOOR DRAIN FIRE EXTINGUISHER CABINET FF FH FHC FIN FLR FND FR FRP FRT FTG FV FVC FXT GA GALV GC GEN GFRC GL GND GR GWB GYP HC HDWR HM HORIZ HP HR FINISH FLOOR FINISH HEIGHT FIRE HOSE CABINET FINISH(ED) FLOOR FOUNDATION FIRE RESISTANT FIBER REINFORCED PLASTIC FIRE RETARDANT TREATED FOOTING FIELD VERIFY FIRE VALVE CABINET FIXTURE GAUGE GALVANIZED GENERAL CONTRACTOR GENERAL GLASS FIBER REINFORCED CONCRETE GLASS GROUND GRADE GYPSUM WALL BOARD GYPSUM HANDICAPPED ACCESSIBLE HARDWARE HOLLOW METAL HORIZONTAL HIGH POINT HOUR HRA HT HTR IAW IC ID INSUL INT ISS JAN JST JT L LAM LAV LP LT MACH MATL MAX MCM MDF MECH MFR MIN MISC MR MTL MWP HOT RUBBERIZED ASPHALT HEIGHT HEATER IN ACCORDANCE WITH INSIDE CLEAR INTERIOR DESIGN INSULATION INTERIOR ISSUE JANITOR JOIST JOINT ANGLE LAMINATE LAVATORY LOW POINT LIGHT MACHINED MATERIAL MAXIMUM METAL COMPOSITE MATERIAL MEDIUM DENSITY FIBERBOARD MECHANICAL MANUFACTURER MINIMUM MISCELANEOUS MOISTURE RESISTANT METAL METAL WALL PANEL NA NIC NO / # NOM NTS O.C. OA OD OD OH OPG OPP ORD PART BRD PC PERF PL PLAM PLUMB PLWD PN PR PT PT PTN R.O. RAD RB RCP RD NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OVERALL OUTSIDE DIAMETER OVERFLOW DRAIN OVERHEAD OPENING OPPOSITE HAND OVERFLOW ROOF DRAIN PARTICLE BOARD PRECAST CONCRETE PERFORATION PROPERTY LINE PLASTIC LAMINATE PLUMBING PLYWOOD PROJECT NORTH PAIR PRESSURE TREATED PAINT PARTITION ROUGH OPENING RADIUS RUBBER BASE REFLECTED CEILING PLAN ROOF DRAIN RE: REQ'D ROW RS SAT SC SCHED SECT SF SHT SIM SM SPEC SQ SS STD STL STRUC SYM T T.O. T.O.B. T.O.C. T.O.D. T.O.F. T.O.F.D. T.O.F.F. T.O.P. REFER TO REQUIRED RIGHT OF WAY ROUGH SAWN SUSPENDED ACOUSTICAL TILE SOLID CORE SCHEDULE SECTION SQUARE FOOT OR FEET SHEET SIMILAR SHEET METAL SPECIFICATION SQUIRE STAINLESS STEEL STANDARD STEEL STRUCTURAL SYMETRICAL TRANSFORMER TOP OF TOP OF BEAM TOP OF CONCRETE TOP OF DECK TOP OF FOOTING TOP OF FLOOR DECK TOP OF FINISH FLOOR TOP OF PARAPET T.O.R. T.O.R.D. T.O.S. T.O.W. TEL TG THK TOPO TYP U.N.O. VAR VCT VERT VEST VIF VWC W.O. W/ W/O WC WD WH WP WWF TOP OF RAIL TOP OF ROOF DECK TOP OF STRUCTURE TOP OF WALL TELEPHONE TEMPERED GLASS THICKNESS TOPOGRAPHY TYPICAL UNLESS NOTED OTHERWISE VARIES VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD VINYL WALLCOVERING WHERE OCCURS WITH WITHOUT WATER CLOSET WOOD WATER HEATER WATERPROOFING WELDED WIRE FABRIC STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: 19022 GENERAL INFORMATION G011 GENERAL CONDITIONS CONSTRUCTION AND MILLWORK NOTES The General Contractor and all Subcontractors shall read the following General Conditions, and project notes as responsibilities affecting all trades are described herein. The General Contractor is responsible for the overall quality and scheduling of the work and the coordination of the various trades. 1.0 Do not scale drawings. Dimensions govern; enlarged plans and details govern over smaller scale. New drywall partitions are dimensioned from face of wall to face of wall unless otherwise noted. Window walls are dimensioned from centerline of mullion or joint to centerline of mullion or joint. Glazing sizes are shown as nominal, actual sizes shall be field verified after glazing system or finished opening is constructed. Electrical and communications outlets or devices are dimensioned from centerline of single outlet or device or group of outlets or devices. Where two or more devices are indicated, each device in a group is to be located immediately adjacent to the next device. 1.0 The reference to ‘Owner’ throughout these documents shall refer to the Landlord’s and/or Tenant’s representatives. Reference to the ‘Contractor’ shall mean the General Contractor in charge of and supervising the work of the project. The reference to ‘CDS’ or ‘Architect’ throughout these documents shall refer to Chord Design Studio, P.C. 1.1 The Contractor shall coordinate all aspects of the project with the Owner and Building Manager. Areas of coordination include, but are not limited to: - Insurance Requirements - Hours and Methods of Access - Project Safety - Building Security and Emergency Procedures - Materials Staging Areas - Hazardous Materials - Access to Trash Facilities - Use and Protection of Elevators and Common Areas - Parking for Supervision and Trades - Deliveries - Other Applicable Contract Provisions and Requirements 1.2 Before performing any work or ordering any materials, the Contractor shall be responsible for verifying all project conditions and his subcontractors, for verifying that actual field conditions are not in conflict with the dimensional relationships and design intent as shown on the drawings. The Contractor shall immediately advise the Architect of any discrepancies and/or conflicts between the existing conditions and the Construction Documents prior to proceeding with the work in question or related work. 1.3 As a minimum standard, all materials and workmanship shall be equal or superior to prevailing industry practices, and all work performed and materials installed shall be in strict accordance with all applicable codes, regulations and ordinances of the governing jurisdiction. Contractor shall obtain all permits required for construction and occupancy of the project. 1.4 Install all manufactured items, materials and equipment in strict accordance with the manufacturer's recommended specifications, unless otherwise specifically noted or approved by the Architect or interior designer in advance of the installation. Where applicable and available from Owner or building management, refer to Building Standard Information for details, assemblies, and typical finish specifications. Notify Architect of any conflicts between building standards and the Contract Documents prior to starting work. 1.5 The Contractor shall be responsible for familiarizing himself with the Owner’s requirements for occupancy, and shall, prior to the start of work, submit a Project Schedule indicating milestone dates, and delivery dates for long lead time items. The schedule shall be updated as necessary throughout the duration of the project. All proposed changes are to be approved by the Owner and Architect. 1.6 All Contractor or Supplier requests for substitutions of specified items shall be submitted to the Architect in writing and be accompanied by proposed alternative product information. A substitution will be considered only if it does not sacrifice quality, appearance and function. Under no circumstances will the Architect be required to prove that a product proposed for substitution is or is not of equal quality to the product specified. 1.7 Installation of all selected materials and assemblies shall be complete and functioning in all respects prior to final acceptance. Any miscellaneous items or materials not specifically noted, but required for proper installation shall be furnished by the Contractor. The Contractor shall furnish to the Owner all warranties and guarantees required at the conclusion of the work. The Contractor is responsible for the inspection, acceptance, storage, installation and continuous protection of all new materials delivered to the project. 1.8 When required by the drawings or specifications, the Contractor shall submit (three complete hard copies or electronic data) shop drawings, schedules and cut sheets for items specified for review by the Architect prior to order or fabrication. When submitting, the Contractor shall notify the Architect, in writing, of any proposed deviations from the Contract Documents, along with the reason for the proposed deviation. Any fabrication carried out prior to the review of the shop drawings by the Architect shall be at the Contractor's risk. CDS will review shop drawings and submittals within ten business days in most cases. Review of these items by the Architect and the Architect’s consultants, shall be for general conformance to the design intent of the project and with the information within the contract documents. Review of a separate item shall not indicate a review of an assembly in which the item functions. Shop drawings that are incomplete or contain excessive errors will be returned unchecked with any resulting delay being the responsibility of the Contractor. The Contractor shall submit and resubmit the required number of copies of corrected shop drawings. Review of shop drawings, submittals and/or samples by the Architect or the Architect’s consultants shall not relieve the Contractor of responsibility for errors and omissions in the items submitted. 1.9 The Contractor shall guarantee that the materials and workmanship shall be of the quality specified or referenced standards, and that any defect due to improper workmanship or defective material discovered and made known within one year from the date of substantial completion of the installation, shall be repaired or replaced with reasonable promptness without additional expense to the Owner. The Owner shall give notice of such observed defects with reasonable promptness. 1.10 Contractor shall perform high quality professional work. Join materials to uniform accurate fits so they meet with neat, straight lines, free of smears or overlaps. Install exposed materials appropriately level, plumb and at accurate right angles, or flush with adjoining materials. Work of each trade shall meet all national standards published by the trade, except in the case where contract documents are more stringent. 1.11 The General Contractor shall at all times cooperate with others who may be performing work at the job site which is not in the general contractor's contract. 1.12 The General Contractor shall provide blocking in partitions as required for all items attached to walls. All blocking shim materials shall be fire resistant in accordance with all applicable codes and requirements. 1.13 Provide necessary outlet boxes, conduit and plastic rings as needed (with pulls) for all telephone/cable/data outlets indicated unless noted otherwise. 1.14 Details are typical for a similar condition throughout, unless otherwise noted. Typical implies typical for all similar conditions, unless otherwise noted. Align implies align other similar components of construction, i.e., face of walls, millwork, etc. 1.15 The Contractor is responsible for continuous and final cleaning and debris removal. The Contractor shall protect and maintain areas outside the project area including paths of travel throughout the building. The Contractor shall construct dust proof partitions to protect common areas, building occupants, building systems, and building finishes. Clean and/or polish surfaces as necessary and appropriate to the material or finish being cleaned. Items to be cleaned include but are not limited to: - Switches, Outlets, Devices, Diffusers, Grilles, Louvers, etc. - Light Fixtures (including lamps, lenses, diffusers and trim) - Plumbing Fixtures & Trim - Sprinkler, Detection, and Life Safety System Components and Trims - Painted or Stained Surfaces - Glass and Glazing Systems (all sides) Remove all labels, dirt, dust, debris, grease, adhesives, paint drips/overspray, and stains, etc. from all surfaces. 1.16 The presence of a representative of CDS on the job site does not imply concurrence or approval of the work. The Contractor shall call specific items to the attention of the CDS representative if he wishes to obtain CDS approval. The Contractor shall document all field approvals with a separate field report or in weekly project minutes. 1.17 If the Contractor, Owner or Tenant substitute a material, revise a construction detail, method of attachment or in any way alter the work so that it does not conform with these documents without CDS written approval, such action will relieve the Architect of any responsibility of liability as to the functionality, aesthetic effect, subsequent failure, property damage or personal liability. 1.18 Contractor shall provide to the Architect a set marked-up Contract Documents indicating the final "as-built" conditions of the project. All architectural, mechanical, electrical, plumbing, and fire protection changes and/or additions shall be legibly shown. 1.1 Replace any firestopping altered in the course of performing the work of the project. For new installation of firestopping, provide product data and certificates certifying compliance with UL and ASTM E 84 and ASTM E 814 requirements. Installation of firestopping to comply with manufacturer’s specifications and with testing agency’s specifications for the required fire-resistance rating. 1.2 For new installation of insulation, provide product data and certificates certifying compliance with UL and ASTM E 84 and ASTM C 665 requirements. Materials and installation of insulation materials to comply with manufacturer’s specifications and with testing agency’s requirements for performance (r-value, STC rating, etc.) and flame spread (maximum 25) and smoke-developed (max 50) surface burning characteristics. 1.3 Do not proceed with gypsum drywall installation over inadequately spaced or poorly aligned framing. It is the General Contractor’s responsibility to coordinate the work of sub-contractors in order to ensure that one sub-contractor does not perform work or install materials over inappropriately finished, damaged, or otherwise poorly prepared work. Notify the architect or designer immediately regarding any concerns or conflicts regarding the compatibility of any finish specified and the preparation or condition of the related substrate. Unless otherwise specified, all gypsum drywall shall receive a Level 4 (GA-214-96) or higher finish. All joints and interior angles have tape embedded in joint compound and two separate coats of joint compound applied over all flat joints and one separate coat of joint compound applied over interior angles. Fastener heads and accessories are covered with three separate coats of joint compound. All joint compound to be smooth and free of tool marks and ridges. Finished surfaces shall be coated with a drywall primer prior to the application of final finishes. Wallboard edges and inside and outside corners shall be crisp and straight or plumb. Reveals, when present, shall be uniform (parallel) and aligned vertically or horizontally unless otherwise specified. Flat surfaces will be free of gouges, trowel marks, and pitting. No corner or edge material, joints or joint tape or tape edges, mud, or screws or screw locations shall be visible or ‘telegraph’ through applied finish materials. Joints shall be taped and joint compound applied to within 3/4” above floor, and finished smooth for installation of final finishes and floor base. 1.4 Within the project area, including the outside faces of perimeter and exterior limits, the Contractor shall seal all penetrations in structure to structure partitions or other existing rated assemblies (floors, chases, etc.), whether caused by the work of the Contractor or existing. All penetrations shall be sealed in a manner that maintains requirements for rated separations between areas. 1.5 The Contractor shall provide slip joints at all wall connections to building envelope or structure, and bracing for all walls below structure. Slip joint construction shall maintain fire rated separation, where applicable. 1.6 The Contractor shall provide and install all plumbing rough-ins, fixture accessories and equipment required to complete the installation as shown and noted. EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 1.7 Where STC rated assemblies are specified, provide materials and assemblies identical to UL or ASTM tested assemblies of the specified rating. Submit testing agency rating for assemblies utilized. 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 1.8 Unless otherwise dimensioned doors shall be set 4" from clear opening of frame to immediate adjacent partition. STRUCTURAL 1.9 All hardware required but not specified in these drawings is to be selected by the Contractor and submitted to the Architect for review before orders are placed. 1.10 Door/Frame/Sidelite System to match building standard unless otherwise noted. Submit product data, finish samples, and door schedule. Doors and Frames shall be rated in accordance with A.S.T.M. procedure for use in fire rated wall assemblies. Comply with ANSI/SDI 100 and NFPA 80 for fire rated door assemblies. All new or modified components shall be labeled by UL or acceptable rating agency. Frames shall encompass the specified finished wall thickness and attach to the wall with all fasteners concealed. Frames shall accommodate 1-3/4" thick doors and surface mounted closers. Jambs shall be overlength to permit custom fitting to the floor. Jamb design shall permit jamb removal and replacement without disturbing the stud fasteners and without damage to the wall finish. Fixed throat jambs shall be adaptable to receive standard flush glazing snap-in sections where sidelites are used. PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 Finished doors shall be trimmed and beveled to fit frame opening with standard clearances as follows: 1/8" at hinge edge, 1/8" at lock edge, 1/8" at top, 1/4" at bottom, stiles beveled 1/8" in 2". In order to insure proper fit to uneven floors, doors shall be ordered with sufficient over-length at bottom to permit custom fitting to floor by the door installer. Doors shall be completely prefinished and machined for all hardware as specified. Door edge finishes shall match face finishes. FINISH NOTES 1.0 Unless otherwise noted, all paints shall be premium commercial grade, low v.o.c. acrylic latex, lowsheen eggshell finish (other than flat) not susceptible to burnishing under normal office and commercial wear. All metal components (access panels, door frames, metal doors, grilles, diffusers, etc.) to be painted shall be semi-gloss latex enamel. All new items shall be shop finished. Unless otherwise noted, contractor shall patch, prepare and repaint all existing partitions shown to remain. Remove all existing device covers, fixtures, furnishings, signage, etc., prior to installing new finishes. Clean and replace/reinstall all items removed prior to painting. 1.1 All HVAC ceiling diffusers and registers shall be prefinished, unless otherwise noted. Caulk around all door frames, glazing systems, grilles, registers, louvers, access panels, and other ceiling and/or wall mounted devices. Caulk color to match device finish. MECHANICAL, PLUMBING, ELECTRICAL, DATA/COMMUNICATIONS & LIFE SAFETY (M/P/E/C/LS) SYSTEMS NOTES 1.0 The Mechanical, Plumbing, Electrical, Data/Communications and Fire Protection contractors shall field verify all existing conditions and shall familiarize themselves with all work and dimensions. The Contractor shall notify the Architect of any conditions or discrepancies adversely affecting the design and installation prior to proceeding with the work. This shall include conflicts with mechanical ducts, piping and structure. Immediately notify Architect if existing M/P/E /C/LS systems are in conflict with the intents of the architectural or engineering design. COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 1.1 Locations of M/P/E/C/LS and life safety components, fixtures, devices, etc., shall be as shown on architectural plans. Refer to Engineering drawings and specifications for system or component integration and performance requirements. If discrepancies between the engineering and architectural drawings occur, notify Architect prior to bidding or installation for clarification. The Contractor shall be responsible for costs of reinstallation of wiring and components when no clarification of discrepancies is requested. The contractor shall be responsible for engineered and code conforming installation of systems provided as ‘Design-Build’ 1.2 No component, fixture or device substitutions shall be permitted without written confirmation from the Architect. Devices include switches, power/data outlets, thermostats, wall stops, Life Safety components, access panels, grilles, diffusers, light fixtures, speakers, etc. If a new component, fixture, or device is not specified, use building standard components, or exactly match components existing within the project area. Seek clarifications where specifications conflict with existing conditions. Verify that all M/P/E/C/LS components to be reused in the project area are functioning and adjusted properly. Clean all new and reused components. Remove all labels unless required to remain by code or manufacturer. All new devices shall be consistent with respect to finish or color and mounting heights. All trim shall be secure, flush to wall and attached with matching hardware. 1.3 Provide fire dampers in all ducts penetrating fire rated or demising partitions. 1.4 The Contractor and Subcontractors shall provide for uninterrupted building utilities and life safety systems operation, unless coordinated with the Owner. 2/17/2020 10:26:31 AM OWNER 1.5 All dimensions to the centerline of an outlet or pair of outlets, unless otherwise noted. All outlets shown back-to-back shall be offset 6" minimum. Provide necessary studwork supports needed for installation. All cover plates to be building standard, unless otherwise noted. Where more than one switch occurs in the same location, they shall be installed in a gang-like box under one cover plate, unless otherwise noted. All existing outlets not utilized by a tenant for electrical, telephone or CRT shall be capped with a blank cover plate - see finish. All thermostats shall be at building standard height unless otherwise noted, and located as shown on mechanical drawings. When thermostats and light switches occur together, install thermostat at 1'-6" above the same witch on centerline, with switch and thermostat aligned vertically on the same partition. 1.6 Mechanical, Plumbing, Electrical, Data/Communications and Life Safety subcontractors shall provide as-built drawings of final circuiting, switching, lighting and HVAC/plumbing diagram. 1.7 Electrical Contractor shall clearly and accurately label all new panel boxes, circuits, and outlet covers associated with the project area. 1.8 Verify telephone /IT-data requirements and telephone equipment board location with the Owner before proceeding with the work. STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: 19022 GENERAL SPECIFICATIONS G012 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:32 AM Project Number: 19022 MATERIAL SPECIFICATIONS G013 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:32 AM Project Number: 19022 MATERIAL SPECIFICATIONS G014 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:33 AM Project Number: 19022 MATERIAL SPECIFICATIONS G015 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:34 AM Project Number: 19022 MATERIAL SPECIFICATIONS G016 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:34 AM Project Number: 19022 MATERIAL SPECIFICATIONS G017 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:35 AM Project Number: 19022 MATERIAL SPECIFICATIONS G018 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:36 AM Project Number: 19022 MATERIAL SPECIFICATIONS G019 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:36 AM Project Number: 19022 MATERIAL SPECIFICATIONS G020 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:37 AM Project Number: 19022 MATERIAL SPECIFICATIONS G021 GOVERNING CODES ARCHITECTURAL DESIGN: 2015 INTERNATIONAL BUILDING CODE (IBC) STRUCTURAL DESIGN: 2015 INTERNATIONAL BUILDING CODE (IBC) MECHANICAL, PLUMBING, AND FIRE PROTECTION DESIGN: 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL FIRE CODE, AS REFEREED BY IBC (IFC) 2015 INTERNATIONAL FUEL GAS CODE (IFGC) ELECTRICAL DESIGN: 3 2017 NATIONAL ELECTRICAL CODE (NEC) ENERGY CONSERVATION DESIGN: 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ACCESSIBILITY DESIGN: ICC/ANSI A117.1 - 2009 AMENDMENTS: 2016 DENVER BUILDING AND FIRE CODE AMENDMENTS FIRE DISTRICT: CITY OF DENVER IECC REQUIREMENTS (CLIMATE ZONE 5) MAXIMUM AREA OF EXTERIOR WALL OPENINGS (IBC TABLE 705.8) DOORS, GATES AND TURNSTILES (IBC 1010) 0' TO LESS THAN 3' FIRE SEPARATION DISTANCE = NOT PERMITTED (UP,S) 3' TO LESS THAN 5' FIRE SEPARATION DISTANCE = 15% (UP,S) 5' TO LESS THAN 10' FIRE SEPARATION DISTANCE = 25% (UP,S) 10' TO LESS THAN 15' FIRE SEPARATION DISTANCE = 45% (UP,S) 15' TO LESS THAN 20' FIRE SEPARATION DISTANCE = 75% (UP,S) 20' TO LESS THAN 25' FIRE SEPARATION DISTANCE = NO LIMIT (UP,S) 25' TO LESS THAN 30' FIRE SEPARATION DISTANCE = NO LIMIT (UP,S) 30' OR GREATER FIRE SEPARATION DISTANCE = NO LIMIT (UP,S) MINIMUM & MAXIMUM DOOR SIZES: 32" AND 48" CLEAR WIDTH, RESPECTIVELY (IBC 1010.1.1) DIRECTION OF SWING: IN DIRECTION OF EGRESS TRAVEL WHERE SERVING > 50 OCCUPANTS (IBC 1010.12.1) DOOR CLOSING: FIRE DOORS SHALL BE SELF- OR AUTOMATIC-CLOSING (IBC 715.4.7). LANDING WIDTH: NOT LESS THAN THE WIDTH OF THE STAIR OR THE DOOR, WHICHEVER IS GREATER. DOORS IN FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED DIMENSION BY MORE THAN 7 INCHES. AT LANDINGS SERVING AN OCCUPANT LOAD > 50, DOOR SWING SHALL LEAVE NOT LESS THAN ONE HALF OF THE REQUIRED WIDTH OF A LANDING. (IBC 1005.7.1) LANDING LENGTH: 44" MINIMUM IN DIRECTION OF TRAVEL. (IBC 1010.1.6) THRESHOLD HEIGHT: 1/2" MAXIMUM (IBC 1010.1.7) PANIC HARDWARE: REQ'D IN AN 'A' OR 'E' OCCUPANCY WHEN SERVING MORE THAN 50 OCCUPANTS ELECTRICAL ROOMS: ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR MORE AND OVER 6 FEET WIDE THAT CONTAIN CURRENT DEVICES, SWITCHING DEVICES OR CONTROL DEVICES -- DOOR SHALL HAVE PANIC/FIRE EXIT HARDWARE AND SWING IN THE DIRECTION OF TRAVEL. DESIGN OCCUPANT LOAD (IBC TABLE 1004.1.2) FUNCTION OF SPACE ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOMS FL. AREA(SF)/OCC. BUSINESS AREAS 100 SF GROSS 300 SF GROSS EGRESS WIDTH PER OCCUPANT SERVED (SPRINKLERED) STAIRWAYS: OTHER EGRESS COMPONENTS: 0.3 INCHES / OCCUPANT (IBC 1005.3.1) 0.2 INCHES / OCCUPANT (IBC 1005.3.2) MINIMUM STAIRWAY WIDTH: 44" (IBC 1011.2) 36" <50 OCCUPANTS (IBC 1011.2;EXC. 1) CLIMATE ZONE 5B: IECC PRESCRIPTIVE PATH MINIMUM RAMP WIDTH: SEE CORRIDOR WIDTH ROOFS (INSULATION ABOVE DECK): R-30CI (U-0.032) MINIMUM CORRIDOR WIDTH: 44" (IBC TABLE 1020.2) 36" <50 OCCUPANTS (IBC 1020.2) 24" ACCESS TO AND UTILIZATION OF MEP SYSTEMS OR EQUIPMENT (IBC 1020.2) WALLS, ABOVE GRADE (MASS): R-11.4CI (U-0.90) WOOD FRAMED WALLS, ABOVE GRADE: R-13 + R-3.8CI (U-0.64) DOOR ENCROACHMENT: DOORS OPENING INTO PATH OF EGRESS TRAVEL SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE-HALF DURING THE COURSE OF THE SWING. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 7 INCHES INTO THE REQUIRED WIDTH. (IBC 1005.7.1) WALLS, BELOW GRADE: R-7.5CI (C-0.199) SLAB ON GRADE FLOORS: F-0.54 (R-10 FOR 24" BELOW GRADE) COMMON PATH OF EGRESS TRAVEL (IBC TABLE 1006.2.1) NON SWINGING OPAQUE DOORS: R-4.75 GROUP A : FIXED FENESTRATION U-FACTOR: U = 0.38 OPERABLE FENESTRATION U-FACTOR: U = 0.45 ENTRANCE DOOR U-FACTOR = U = 0.77 75 FEET MAXIMUM SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY (IBC TABLE 1006.2.1) OCCUPANCY GROUP A SHGC: SEW* - SHGC = 0.40 (PF < 0.2) N* - SHGC = 0.53 (PF < 0.2) SEW* - SHGC = 0.48 (PF 0.2 < PF < 0.50) N* - SHGC = 0.58 (PF < 0.2) SEW* - SHGC = 0.64 (PF > 0.50) N* - SHGC = 0.64 (PF < 0.2) MAX. OCC. LOAD 49 *"N" INDICATES VERTICAL FENESTRATION WITHIN 45 DEGREES OF TRUE NORTH "SEW" INDICATES ORIENTATION OTHER THAN "N" DISTANCE BETWEEN EXITS (IBC 1007.1.1) MINIMUM SEPARATION BETWEEN EXITS SHALL NOT BE LESS THAN 1/2 OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED) EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2) GROUP A: CODE SUMMARY 18201 GREEN VALLEY RANCH BLVD, DENVER, CO 80249 1 STORIES (IBC 504.4) HEIGHT = 40' - 0" (IBC 504.3) 1 STORIES HEIGHT = 25' - 0" ALLOWABLE BUILDING AREA: GROUP A-2 6,000 S.F. ACTUAL BUILDING AREA: 2,343 S.F. 20 FEET MAXIMUM t: 303.694.2445 4. SPECIAL INSPECTIONS (IBC 1705). - STEEL CONSTRUCTION: WELDS, CUTS AND HIGH-STRENGTH BOLTING. - CONCRETE CONSTRUCTION. - MASONRY CONSTRUCTION. - SOILS. - PIERS. - SPRAY FIRE RESISTANT MATERIALS (FIRE-PROOFING STEEL AND FLOORS. - SPECIAL CASES: AS DETERMINED BY THE CITY OF DENVER BUILDING DEPARTMENT. 6. CODE REQUIRED SIGNAGE, INCLUDING BUT NOT LIMITED TO: - ACCESSIBILITY - DOORS - ELEVATORS - ASSEMBLY OCCUPANT CONTENT - TACTILE EXIT SIGNAGE . - STAIR IDENTIFICATION - STANDPIPE CONTROL GENERAL BUILDING CODE COMMENTS CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 2. FIRE RESISTANCE RATINGS OF SHAFT ENCLOSURES SHALL COMPLY WITH IBC 707.4, BUT SHALL NOT BE LESS THAN THE FLOOR ASSEMBLY PENETRATED. 3. MEMBRANE PENETRATIONS SHALL COMPLY WITH IBC 712.3.2. (SEE EXCEPTIONS FOR ELECTRICAL BOXES, ETC). MINIMUM NUMBER OF EXITS PER STORY (IBC TABLE 1006.3.1) OCCUPANCY LOAD (persons per story) 1 - 500 501 - 1000 MORE THAN 1000 MINIMUM NUMBER OF EXITS 2 EXITS 3 EXITS 4 EXITS 4. PENETRATIONS OF MEMBRANES THAT ARE PART OF A FIRE-RESISTANT RATED HORIZONTAL ASSEMBLY SHALL COMPLY WITH IBC 712.4. 5. EXTERIOR CURTAIN WALL / FLOOR INTERSECTIONS SHALL COMPLY WITH IBC 713.4. 6. OPENING PROTECTIVES SHALL COMPLY WITH IBC TABLE 715.4. *S1 = BUILDINGS A MAXIMUM OF ONE STORY ABOVE GRADE PLANE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 7. FIRE DOORS SHALL BE LABELED IN ACCORDANCE WITH IBC 715.4.5 THRU 715.4.5.1. INTERIOR WALL AND CEILING FINISH REQUIREMENTS (IBC TABLE 803.11) FIRE RESISTANCE RATING REQUIREMENTS - TYPE V-B (IBC TABLE 601) PRIMARY STRUCTURAL FRAME (INCLUDING COLUMNS, GIRDERS, BEAMS, TRUSSES & SPANDRELS) BEARING WALLS EXTERIOR INTERIOR NONBEARING WALLS AND PARTITIONS EXTERIOR (IBC TABLE 602) INTERIOR FLOOR CONSTRUCTION (AND SECONDARY MEMBERS) ROOF CONSTRUCTION (AND SECONDARY MEMBERS) CHORD DESIGN STUDIO, P.C. 1. A CERTIFICATE OF OCCUPANCY MUST BE OBTAINED BY THE TENANT PRIOR TO OCCUPYING ANY BUILDINGS OR PORTIONS OF BUILDINGS. DEAD END CORRIDORS (IBC 1020.4) GROUP A OCCUPANCY: CONSTRUCTION TYPE: V-B (NON-SPRINKLERED) (IBC TABLE 503) ARCHITECT 2. GLAZED ALUMINUM CURTAIN WALL SHOP DRAWINGS. 1 HOUR IF MORE THAN 30 OCCUPANTS SERVED WIDTH: AS DETERMINED BY IBC 1005.3.2, BUT NOT < THAN 44" (IBC 1020.2); 24" FOR ACCESS TO MEP EQUIPMENT (IBC 1020.2); 36" WITH REQUIRED OCCUPANCY OF < 50 (IBC 1020.2) RESTAURANTS, CAFETERIAS AND SIMILAR DINING FACILITIES (INCLUDING ASSOCIATED COMMERCIAL KITCHENS) (IBC SECTION 303.3) ACTUAL BUILDING HEIGHT: GROUP A: 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 1425 MARKET STREET SUITE 220 DENVER, CO 80202 CORRIDOR FIRE RESISTANCE RATING (IBC TABLE 1020.1) USE AND OCCUPANCY CLASSIFICATIONS ALLOWABLE BUILDING HEIGHT: GROUP A-2 200 FEET MAXIMUM W/ NO SPRINKLER EVC-WDG TOWER II, LLC 1. FIRE ALARM SHOP SUBMITTAL. 5. FINAL PLAT OR SURVEY. PROJECTION FACTOR 'PF' SHALL BE EVALUATED SEPARATELY, OR AN AREA WEIGHTED VALUE SHALL BE CALCULATED AND USED FOR ALL WINDOWS AND GLASS DOORS. A-2: DOCUMENTS FOR DEFERRED SUBMITTAL SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 3. ROOFING SYSTEMS CONFORMANCE TO WIND / DEFLECTION CRITERIA. SWINGING OPAQUE DOORS: U-0.37 BUILDING ADDRESS: DEFERRED SUBMITTALS (IBC 107.3.4.1) OWNER 0 HOUR 0 0 HOUR HOUR SEE CODE PLANS AND ELEVATIONS 0 HOUR SPACE TYPE EXIT ENCLOSURES AND EXIT PASSAGEWAYS CORRIDORS ROOMS AND ENCLOSED SPACES A CLASS B CLASS C CLASS C PROVIDE FLAMESPREAD CERTIFICATION OF ALL FINISH MATERIALS IN COMPLIANCE WITH IBC 803.1.2 8. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE (11 LUX) AT THE FLOOR LEVEL. (RE: IBC 1006.1 AND 1006.2) 9. HANDRAILS SHALL COMPLY WITH IBC 1012.1 THRU 1012.8. GUARDS SHALL COMPLY WITH IBC 1013.1 THRU 1013.6 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 3 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 INTERIOR FLOOR FINISHES SHALL COMPLY WITH IBC 804. FIRE SPRINKLER (IBC TABLE 903.2.1.2) 0 HOUR 0 HOUR PENETRATIONS SHALL COMPLY WITH SECTION 712 IBC. GROUP A-2: NOT REQ'D, FIRE AREA LESS THAN 5000 SF AND OCCUPANT LOAD LESS THAN 100 FIRE ALARM (IBC TABLE 907.2.1) GROUP A: NOT REQ'D, FIRE LESS THAN 300 OCCUPANTS FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE - TYPE V-B (TABLE 602) MINIMUM ROOF COVERING CLASSIFICATION REQUIREMENTS (IBC TABLE 1505.1) SEPARATION DISTANCE X < 5' FIRE SEPARATION DISTANCE 5' ≤ X ≤ 10' FIRE SEPARATION DISTANCE 10' ≤ X ≤ 30' FIRE SEPARATION DISTANCE X > 30' FIRE SEPARATION DISTANCE GROUP A 1 HOUR 1 HOUR 0 HOUR 0 HOUR TYPE V-B: CLASS C STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:38 AM Project Number: CODE SUMMARY G031 19022 EGRESS LEGEND SYMBOL DESCRIPTION COMMON PATH OF TRAVEL: 75' MAX (TYPICAL OCCUPANCY) 25' MAX (H OCCUPANCY) 100' MAX (FULLY SPRINKLERED B, F & S OCCUPANCY) COMMON PATH OF TRAVEL: 2 SEPARATE PATHS OF EGRESS TO SEPARATE EXITS OVERALL DIAGONAL DIMENSION 6 DISTANCE BETWEEN EXITS (< 1/3 OVERALL DIAGONAL DIMENSION) OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 TRAVEL DISTANCE BACK OF HOUSE KITCHEN, COMMERCIAL FUNCTION: AREA SUBTOTAL: 1046 SF 200 SF / OCC GROSS LOAD FACTOR: OCCUPANT LOAD: 6 MAXIMUM EXIT ACCESS TRAVEL DISTANCE OCCUPANCY FRONT OF HOUSE ASSEMBLY FUNCTION: AREA SUBTOTAL: 1129 SF 15 SF / OCC NET LOAD FACTOR: OCCUPANT LOAD: 76 NON-SPRINKLERED SPRINKLERED A, E, F-1, M, R, S-1 200' 250' B 200' 300' F-2, S-2, U 300' 400' I-1, I-2, I-3, I-4 NP 200' OCCUPANCY 2 EXITS REQ'D WHEN OCCUPANT LOAD > THAN A, B, E, F, M, U 49 H-1, H-2, H-3 3 H-4, H-5, I-1, I-2, I-3, I-4, R 10 S 29 NOTES: SEE CODE SUMMARY FOR ADDITIONAL EGRESS INFORMATION 38 OCCUPANT LOAD & EXITING LEGEND ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 OCCUPANT LOAD MEP GIVEN & ASSOCIATES 9" " 1/2 76'L= 8'-4 NA =3 GO 1/2 DIA "X 6'-9 ALL =7 ER OV ON ATI AR EP DS IRE QU RE 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 =4 7'-1 " THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. DESCRIPTION PERMIT SET DATE 27 DEC 2019 DIS TAN C EB ETW EEN EXI TS # 1 38 61 PATIO ASSEMBLY FUNCTION: AREA SUBTOTAL: 332 SF 15 SF / OCC NET LOAD FACTOR: OCCUPANT LOAD: 23 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:39 AM Project Number: 19022 CODE STUDY PLAN 1 CODE STUDY PLAN SCALE: 3/16" = 1'-0" G201 91.66' (RE: CIVIL) 54.95' (RE: CIVIL) OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 29.0' (RE: CIVIL) 1425 MARKET STREET SUITE 220 DENVER, CO 80202 TRASH ENCLOSURE t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 WALDEN STREET 30' - 0" 33' - 4" 18.86' (RE: CIVIL) 73' - 4" 168.36' (RE: CIVIL) BUILDING AREA: 2,343 SF SITE AREA: 0.58 ACRES PARCEL: W1A 34' - 9" COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 30' - 0" ZONE LOT LINE, TYP 2/17/2020 10:26:40 AM 41.88' (RE: CIVIL) STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: CODE SITE PLAN G202 96.12' (RE: CIVIL) GREEN VALLEY RANCH BLVD 1 CODE STUDY SITE PLAN SCALE: 3/32" = 1'-0" 19022 LOGO RIDGETOP PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE GATEWAY CROSSING PARCEL W1A NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS DATE 01/10/2020 SHEET TITLE COVER SHEET SHEET INFORMATION R CONSTRUCTION SET Know what's below. CV-1 Callbefore you dig. 1 Of 10 PLANNED BUILDING GROUP WEST 4TH AMENDMENT East 14 corner Section 16, Township 3 South, Range 66 West 3.25" aluminum cap marked LS 36053 (2005) DESCRIPTION: traffic signal control box LEGAL 86' Lot 1, Block 2, TOWER 160 SUBDIVISION, Reception Number 2008079854, recorded June 10, 2008, public records County of Denver, State of Colorado. 36' ' .17 472 I 60 O ,T ,B c lo k ER W SU BD 36' PLS 38158 15.8' (to flow-line) Containing 10.480 acres (456,502 sq. ft.) more or less. 293.11' (M) 15.4' (to flow-line curb and gutter (M) PLS 38158 storm inlet 36' (R) LEGEND: edge of asphalt (R) R=15.00' L=23.56' =90°00'00" Ch=21.21' CB=S 45°07'05" E (R) R=564.00' L=443.84' =45°05'19" Ch=432.47' CB=N 67°20'15" E electric pull box storm inlet (M) (M) ric ct box e l e ull p 1 (72' Right-of Way) N 89°52'55" E 236.10' Δ = = 4 6 0 '16 " W ' Ch 7°20 .14 6 47 2 = S L = 0' CB 0 .0 0 =6 )R (M N S 89°53'20" W 49th Ave. L= 00''19" . 0 60 5 R= 5°0 '10 " (R) D =44 5 ° 0 5 . 0 5 ' O SI VI (R) S 89°52'55" W 293.10' RANGE LINE found 0.5" iron rod with 1.0" plastic cap marked as described found 0.5" iron rod with 2.5" aluminum cap marked PLS 36072 in monument box set 0.5" iron rod with 1.0" plastic cap marked PLS 32444 set 0.5" iron rod with 2.5" aluminum cap marked PLS 32444 in monument box light pole 1 electric pedestal storm sewer manhole 1 ot sanitary sewer manhole L S 00°07'05" E 356.52' (M) (R) boundary line 10' Public Service Company Easement Inst. No. 20050314000261080 (Adams County March 14, 2005) Rec. No. 2007098165 (March 14, 2005) and Rec. No. 2008079048 (June 9, 2008) (City and County of Denver) Lot 1, Block 3, TOWER 1601.56' SUBDIVISION S 89°52'23" W S 89°52'23" W ±8.402 acres ±365,999 sq. ft. 1 corner Section 16 , East-East 20 (Rec. No. 2008079854) 64 0.2' PLS 38158 20' Public Service easement Book 1590, Page 29 (Adams County April 9, 1970) Rec. No. 2008079049 (City and County of Denver June 9, 2008) electric pull box S 89°52'23" W 728.72' (M) (R) electric transformer cable TV pedestal electric I, M. Bryan Short, a duly registered Professional Land Surveyor in the State of Colorado, do transformer hereby state to the best of my knowledge, information and belief that this Improvement Survey Plat POINT OF for the GATEWAY CROSSING PBG EAST truly and correctly represents the results of a BEGINNING monumented land survey made under my responsible charge and is in accordance with applicable standards of practice. This is not a guaranty or warranty, either expressed or implied. concrete sidewalk electric vaults traffic control boxes 14.6' (to flow-line) 60' curb and gutter communications vault 14.5' (to flow-line) 60' S 89°52'23" W 68' Yampa St. (100' Right-of Way) 50' 2. Yampa Street was not developed at the time of this survey. electric POINT OF transformer 3. Bearings are based on the South line of the Southeast 1BEGINNING 4 of Section 16, Township 3 South, Range 66 West of the 6th P.M. as bearing S 89°52'23" W, per TOWER 160 SUBDIVISION. traffic control vault edge of asphalt 4. N 864.89' (M) (R) City of Denver Benchmark 581A. Published NAV 88 Datum Elevation = 5380.35' 2" brass cap at back of walk in the Southeast corner of the intersection of 48th Avenue and Tower Road RANGE LINE communications vaults storm inlet 51 °2 96 driveway Distances shown are in U.S. Survey Feet. 7'4 4' 7" Green Valley Ranch Blvd. W (Right-of Way varies) see "Detail" this sheet Basis of Bearings S 89°52'23" W 2645.65' South line of the Southeast 14 of Section 16, Township 3 South, Range 66 West South 4 corner Section 16, Township 3 South, Range 66 West 3.25" aluminum cap marked LS 36053 (2005) 1. PLS 38158 .0 (Right-of Way varies) 1 NOTES: storm inlet Green Valley Ranch Blvd. 1120.76' Parcel E7 M. Bryan Short, ±1.515 P.L.S.,ACRES #32444 PLS 38158 electric vault curb and gutter SURVEYOR'S CERTIFICATION: 50' 0.3' Tower Rd. Detail electric transformers R=25.00' L=39.32' =90°07'24" Ch=35.39' CB=N 45°03'55" W (R)R=25.00' L=39.27' D =89°59'28" (M) R=25.00' L=39.26' =89°59'19" Ch=35.35' CB=S 44°52'47" W S 00°07'05" E 135.94' (M) (R) N 00°00'12" W 13.5' (to flow-line) 2.6' PLS 38158 (M) (R) storm inlet Township 3 South, Range 66 West found 3.25" aluminum cap marked LS 36053 (2005) (no improvements) W 1.56' S 00°15'23" E 2658.22' East line of the Southeast 14 of Section 16, Township 3 South, Range 66 West easement line driveway N 00°07'08" W 748.46' Lot 1, Block 3, TOWER 160 SUBDIVISION section line scale: 1" = 5' RANGE LINE concrete sidewalk (R) right of way line PLS 38158 193.85' (M) curb and gutter Walden St. (72' Right-of Way) 36' RANGE LINE S 00°00'36" E 279.00' (M) 36' 2.5' PLS 38158 13.5' (to flow-line) rangeline (Right-of Way varies) S 03°41'47" W 12 0.26' (M) (R) PLS 38158 748.46' (M) ±10.480 acres ±456,502 sq. ft. (Rec. No. 2008079854) (R) recorded N 00°07'08" W R=3 (M) (R) S 00°07'05" E 748.44' Lot 1, Block 2, TOWER 160 SUBDIVISION public access easement (Rec. No. 2019078485) (R) S 00°00'12" E 278.98' 42' electric transformer (no improvements) 100 measured (M) 42' (R) R=320.00' L=250.19' D =44°47'49" (M) R=320.00' L=250.19' =44°47'51" Ch=243.87' CB=N 22°23'41" E 50 bollard 2.5' 13.4' (to flow line) =S 7 " 2 2 ° 1. 3 5 ' 23 5 6. '48 00' " W L= 27 8. 3 8' (R)R = D =4356.00' L Δ = 4°4 4 4 ° 7'4 =278 9 .34' C B C h = 2 4 8 '15 " electric pull box 25 0 sign Yampa St. PLS 38158 50 (84' Right-of Way) ) (M 15.4' (to flow-line) 44 60. °4 11 7'3 ' (M 6" ) E N 60 44 S ) (R public access easement (by future document) S 89°52'23" W Scale 1 inch = 50 feet water valve concrete sidewalk ) R (W °4 7' 3 .1 5" 3' W " 36 ' 7 ' ° 4 .11 4 0 4 S 6 E 1" '0 6 °2 9' 45 5.6 8 N electric transformer found Section corner monument as described East-East 164 corner Section 16 20 , Township 3 South, Range 66 West found 3.25" aluminum cap marked LS 36053 (2005) West 1.56' from range point S 89°52'23" W 660.00' POINT OF COMMENCEMENT Southeast corner Section 16, Township 3 South, Range 66 West 3.25" aluminum cap marked LS 36053 (2005) 71' SHEET TITLE OVERALL SURVEYWEST 5255 Ronald Reagan Blvd., T (970) 663-4552 Ste. 210 W ridgetopeng.com Johnstown, CO 80534 2 Of 10 GATEWAY CROSSING PBG WEST- 2018PM0000677 AMENDEMENT NO. 1 - 2018PM0000544; AMENDMENT NO. 2 - 2019PM0000138; AMENDMENT NO. 3 - 2019SDP0000282; AMENDMENT NO. 4 - 2019PM0000456 LOGO RIDGETOP LEGEND PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE *NOTE* GATEWAY CROSSING PARCEL W1A 49TH AVE (PUBLIC ROAD) *PUBLIC ACCESS EASEMENT NOTE* NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC D PARCEL W5 AMENDMENT NO. 2 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 YAMPA ST. (PUBLIC ROADWAY) PARCEL W7 AMENDMENT NO. 3 D ROAD F (PRIVATE ROADWAY) D CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 WALDEN ST (PUBLIC ROAD) ROAD E (PRIVATE ROADWAY) PARCEL W1A AMENDMENT NO. 4 SUBMITTAL PBG WEST 4TH AMENDMENT PARCEL W2 ORIGINAL PBG WEST PARCEL W4 AMENDMENT NO. 1 DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS GREEN VALLEY RANCH BLVD. (PUBLIC ROAD) DATE 01/10/2020 SHEET TITLE OVERALL SITE PLAN SHEET INFORMATION R CONSTRUCTION SET Know what's below. OS-1.0 Callbefore you dig. 3 Of 10 LOGO BUILDING DATA RIDGETOP LEGEND PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE D GATEWAY CROSSING PARCEL W1A ROAD E (PRIVATE ROADWAY) NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 WALDEN ST (PUBLIC ROADWAY) CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS D GREEN VALLEY RANCH BLVD (PUBLIC ROADWAY) DATE 01/10/2020 SHEET TITLE PARCEL W1A SITE PLAN SHEET INFORMATION R CONSTRUCTION SET Know what's below. C-2.0 Callbefore you dig. 4 Of 10 LOGO RIDGETOP LEGEND PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL ROAD E (PRIVATE ROADWAY) PROJECT TITLE GATEWAY CROSSING PARCEL W1A WALDEN ST (PUBLIC ROADWAY) D NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: D MRB PROJECT NO.: 19-064-009 REVISIONS SUDP REVISIONS GREEN VALLEY RANCH BLVD (PUBLIC ROADWAY) GRADING NOTES CHECKED BY: 02-14-2020 DATE STORM DRAINAGE NOTES 01/10/2020 SHEET TITLE PARCEL W1A GRADING PLAN SHEET INFORMATION R CONSTRUCTION SET Know what's below. C-3.0 Callbefore you dig. 5 Of 10 LOGO LEGEND SURVEY LEGEND found Section corner monument as described PLANNED BUILDING GROUP WEST 4TH AMENDMENT found 0.5" iron rod with 1.0" plastic cap marked as described RIDGETOP ENGINEERING & SURVEYING set 0.5" iron rod with 1.0" plastic cap marked PLS 32444 541 E. Garden Drive, Unit N Windsor, CO 80550 electric transformer-box electric vault-ground level box T (970) 663-4552 W ridgetopeng.com SEAL light pole telecommunication pedestal telecommunication manhole water manhole fire hydrant water valve DENVER WATER STANDARD NOTES storm sewer manhole PROJECT TITLE sanitary sewer manhole - septic tank lid GATEWAY CROSSING PARCEL W1A sign fence line ohw ROAD E (PRIVATE ROADWAY) SANITARY SEWER NOTES overhead utility wire e electric line t telephone line w water line g gas line ss sanitary sewer line NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC storm sewer line 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER GENERAL UTILITY NOTES PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 WALDEN ST (PUBLIC ROADWAY) AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS DATE GREEN VALLEY RANCH BLVD (PUBLIC ROADWAY) 01/10/2020 SHEET TITLE PARCEL W1 UTILITY PLAN Approved for Construction SHEET INFORMATION R CONSTRUCTION SET Know what's below. Callbefore you dig. C-4.0 6 Of 10 GENERAL LANDSCAPE NOTES ROAD E PLANNED BUILDING GROUP WEST 4TH AMENDMENT 4-HHR 4-MSG 11-RFG 3-CCI 2-MSS 6-JHBC 24-KA PROPOSED PLANT LIST WALDEN ST LIGHT POLES KEY 9-PSC 2-RxM 8-KA 4-AxC 3-MSG 5-HHR 2-BTC 1-QB BOTANICAL NAME COMMON NAME SIZE NOTES 2" cal B+B ADBL GROWTH QTY. HEIGHT DECIDUOUS TREES LIGHT POLES 2-SJF 6-PFJ 2-JHBC 2-GTS 2-CAA English Oak 40' 1 M 40' 2 B+B M 40' 1 6' ht. B+B L 40' 2 25 gal. cont. L 15' 11 QB Quercus robur GTS Gleditsia triocanthos inermis 'Shadem' Shademaster Locust 2" cal B+B UxC Ulmus x 'Cathedral' Catherdral Elm 2" cal M EVERGREEN TREES PN Pinus nigra Austrian Pine JV Juniperus scopulorum Rocky Mountain Juniper 2-PN 2-MSG 4-LX CCI Crataegus crus-galii inermis Thornless Cockspur Hawthorne 1.5" cal B+B L 15' 3 5-PAT MSS Malus 'Spring Snow' Spring Snow Crabapple 1.5" cal B+B L 15' 2 PCC Pyrus calleryanna 'Autumn Blaze' Autumn Blaze Maple 1.5" cal B+B L 15' 2 5 gal. 5' o.c. L 2' 15 3' o.c. L 3' 7 ORNAMENTAL TREES 6-PFJ EVERGREEN SHRUBS 2-MSG 4-JHBC 11-JV 4-RxM JHBC Juniperus horizontalus 'Blue Chip' Blue Chip Juniper JPGM Juniperus procumbens 'Green Mound' Green Mound Juniper 5 gal. LIGHT POLES 3-JHBC DECIDUOUS SHRUBS 1-UxC 2-PFJ 6-KA 16-LAH LIGHT POLES Office of the City Forester (OCF) Standard General Plan Notes: MONUMENT SIGN 7-HHR 2-PCC 3-CAA 1. Existing trees required to be preserved in ROW and/or public place shall be protected per OCF standards and practices. Tree protection shall be installed prior to issue of demolition/building permit, approved by the OCF, and shall remain as approved throughout construction. No access, construction activities or storage of construction materials/debris/equipment shall take place within tree protection zones without prior written authorization from the OCF. LIGHT POLES 20-SJF 20-AxC 2. Per City Code, all tree removals in City/County of Denver must be performed by the property owner or a tree contractor licensed by OCF, including trees in ROW, public place and private property. For a current list of licensed tree contractors, visit www.denvergov.org/Forestry. A. OCF-approved tree removals in ROW or public place; i. A tree removal permit issued by the OCF is required prior to removal. Tree removal permits are not included with building permits or plan approvals and must be obtained separately from the OCF. Contact the OCF (Forestry@denvergov.org) with name of licensed contractor or property owner performing removal. Include project number (2019PM0000456) and project address(4859 N.Yampa Street). MINIMUM SITE LANDSCAPE CALCULATIONS 1 TREE/200 sq ft of LANDSCAPING 50% LIVING MATERIAL PROVIDED 5% of 6,079 sq ft = 303 sq ft 586 sq ft 586/200=2.93 TREES 3 TREES 6,079 sq ft of landscape area provided 50% = 3,040 sq ft Do not cut single leader. Prune only damaged, dead wood, or co-dominant leaders. 12" nylon tree strap with grommets on guy wire. Do not twist straps tight around trunk. 2,767 sq ft irr. turf 1,667 sq ft shrubs & perennials 1/2" diameter white PVC pipe section on entire length of each wire. 78% living material 14-Gauge galvanized wire, double strand. Leave 1" to 2" slack in wire to allow for trunk movement. ROW = 2,842 sq ft with 100% living material not included in calcs. If needed, 6' steel T-post or wood stake (install to 2' depth in undisturbed subgrade) with safety caps, set to windward side and other opposite; or other pre-approved staking method. Deciduous Tree Fall Planting: Wrap trunk to first branch with specified tree wrap material. Secure at top with masking tape. Do not wrap rough bark trees. Remove trunk wrap in spring after last frost. Set top of root flare (first order roots) at or 1" above finish grade. Remove excess soil from top of root ball and adventitious roots on trunk. Circle of shredded wood mulch, 3" deep and 4" to 6" away from trunk, to outer edge of planting hole. Form 2" high dirt saucer around pit at outside of transition zone. Finish Grade Completely remove all twine and wire basket. Pull burlap down minimum 2/3 of ball, cut and remove from pit. Slope sides of planting pit as shown, roughen sides prior to backfill. Little Princess Spirea 5 gal. 3' o.c. 3' 22 PAT Perovskia atriplicifolia Russian Sage 5 gal. 3' o.c. 4' 5 RxM Rosa x "Knock Out' Knock Out Rose 5 gal. 4' o.c. 4' 6 AxC Arctostaphylos x coloradoensis Panchito Manzanita 5 gal. 4' o.c. 6' 24 PFJ Potentilla fruticosa 'Jackmani' Jackman Potentilla 5 gal. 3' o.c. 4' 14 CAA Cornus alba 'Argenteomarginata' Variegated Dogwood 5 gal. 5' o.c. 5' 5 BTC Berberis thunbergii 'Crimson Pygmy' Crimson Pygmy Japanese Barberry 5 gal. 3' o.c. 3' 2 LV Ligustrum x vicaryl Golden Vicary Privet 5 gal. 4' o.c. 4' 4 PERENNIALS AND ORNAMENTAL GRASSES KA Calamagrostis x acutiflora 'Karl Forester' Karl Forester Grass 1 gal. 18" o.c. 5' 38 HHR MSG Hemerocallis 'Happy Returns' Myiscanthus sinensis 'Gracilimus' Dwarf Yellow Day Lily Gracilimus Grass 1 gal. 18" o.c. 2 gal. 4' o.c. 2' 4' 16 11 RFG Rudbeckia fulgida 'Goldstrum' Black-Eyed Susan 1 gal. 24" o.c. 2' 11 LAH PSC Lanvandula angustifolia 'Hidcote' Phlox subulata Deep Blue Lavander Creeping Phlox 1 gal. 1 gal. 12" o.c. 12" o.c. 12" 12" 16 9 B. A tree removal permit is not required for private property tree removals. 3. All proposed landscaping in the ROW shall be per the Streetscape Design Manual with the exception of tree planting, this shall be in accordance with current OCF Rules and Regulations. 4. All electric fixtures and utilities, including but not limited to outlets and lights, shall be located at outside perimeter of tree planting areas within hardscape. In tree lawns, fixtures shall be placed minimum 3 (three) feet radially from base of trunk. 5. An OCF-issued tree planting permit is required for all trees to be planted in ROW or public place. Contact OCF (Forestry@denvergov.org) with name of contractor or property owner performing work. Include project number (2019PM0000456) and project address (4859 N. Yampa Street) when requesting permit. Tree planting permits are not included with building permits and must be obtained separately from the OCF prior to installation. 0 6. Proposed tree planting in the Right-of-Way (ROW) or public place shall be pre-approved by the Office of the City Forester (OCF) and shall be a minimum of; A. 30' from outside edge of intersecting curbs for sight triangle B. 20' from stop signs C. 25' from street lights 2X Root Ball Diameter D. 20' from pedestrian curb ramps 3-4 X Root Ball Diameter E. 10' from edge of vehicular drive apron and hydrants. Native soil or appropriate planting media. LANDSCAPE LEGEND 10 20 40 SCALE: 1" = 20' Undisturbed subgrade. Any broken, crumbling, or otherwise damaged rootball should be rejected. Do not damage during planting. 1 2 X X 1 2 X STA Trees planted upon park land, public property, or within the Public Right of Way (PRW) are subject to the following restrictions: · · · · · · · · · · · · · · · An approved planting permit from the Office of the City Forester (OCF), regardless of approved plans, is required prior to planting. Penalties shall be issued for trees planted without an OCF issued permit. Only tree species approved by or listed on the OCF's approved street tree list shall be planted in PRW. For a list of prohibited or suspended PRW trees, contact or visit the OCF website. If overhead utility wires exist in the PRW, only ornamental or trees maturing at 20 (twenty) feet maximum height shall be planted. Trees shall be centered in tree lawns and/or planting areas. Trees shall not be planted in tree lawns less than five feet wide unless authorized by the OCF. Where sidewalks are not present, trees shall be located as designated by Office of the City Forester. Planting in corner triangle formed by the first 30 (thirty) feet along the PRW in each direction from the corner is not permitted. Planting within 10 (ten) feet of alleys, driveways, or fire hydrants is not permitted. Planting within 20 (twenty) feet of stop signs is not permitted. Planting within 25 (twenty-five) feet of street lights is not permitted. Planting within five feet of water meters or pits is not permitted. Large shade trees shall be spaced 35 (thirty-five) feet o.c. and ornamental trees 25 (twenty-five) feet o.c. or as designated by OCF. All electric fixtures and utilities, including but not limited to outlets and lights, shall be located at outside perimeter of tree planting areas within hardscape. In tree lawns, fixtures shall be placed minimum 3 (three) feet radially from base of trunk. Prior to digging, the Utility Notification Center of Colorado shall be contacted at 811 to locate underground utilities. 7. All plant material shall meet or exceed current American Standard for Nursery Stock ANSI Z60.1 and the Colorado Nursery Act and accompanying Rules and Regulations. 8. K R A M NITELLU B ETA D PREPARED BY OFFICE OF THE CITY FORESTER, DENVER PARKS AND RECREATION DEPARTMENT CITY AND COUNTY OF DENVER 201 W. COLFAX AVE. DENVER, COLORADO 80202 ELA C SO TO N T STANDARD RESIDENTIAL TREE PLANTING D DETAIL FOR SOD AREA OR TREE LAWN 81/41/9 :ETA A.1-PM G A RID DATE 01/10/2020 Required soil remediation when removing hardscape/concrete/asphalt/pavers/etc. to plant trees): A. Soil analysis, bulk density testing and remediation required when removing hardscape to plant trees; including but not limited to concrete, asphalt, pavers, brick i. Deep soil analysis to 24” depth required from credited, local soil analysis laboratory with experience in local urban soils. SHEET TITLE R ii. Analysis must determine soil texture and type, pH balance, soil salinity, organic matter (OM) percentage, and plant available nutrients B. S N OISIVE R 21-100 PARKING SPACES REQUIRED Spiraea japonica 'Little Princess' ii. Existing ROW or public place trees approved for removal by the OCF must be protected in place until removed by an OCF licensed tree contractor. Failure to protect such trees until removal, or removing trees without a permit, will result in a notice of violation and/or citations/fines. 6,079 sq ft open space/Landscaping DESCRIPTION SJF LANDSCAPE PLAN Know what's below. Soil Remediation required based on soil analysis. 9. Contact the OCF a minimum of five (5) business days before commencement of demolition and/or construction activity. Call before you dig. 07 Of 10 GATEWAY CROSSING PBG WEST- 2018PM0000677 AMENDEMENT NO. 1 - 2018PM0000544; AMENDMENT NO. 2 - 2019PM0000138; AMENDMENT NO. 3 - 2019SDP0000282; AMENDMENT NO. 4 - 2019PM0000456 LOGO RIDGETOP PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE GATEWAY CROSSING PARCEL W1A NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS DATE 01/10/2020 SHEET TITLE DETAILS SHEET INFORMATION R CONSTRUCTION SET Know what's below. C-5.0 Callbefore you dig. 8 Of 10 LOGO RIDGETOP PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE GATEWAY CROSSING PARCEL W1A NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS DATE 01/10/2020 SHEET TITLE DETAILS SHEET INFORMATION R CONSTRUCTION SET Know what's below. C-5.1 Callbefore you dig. 9 Of 10 LOGO RIDGETOP PLANNED BUILDING GROUP WEST 4TH AMENDMENT ENGINEERING & SURVEYING 541 E. Garden Drive, Unit N Windsor, CO 80550 T (970) 663-4552 W ridgetopeng.com SEAL PROJECT TITLE GATEWAY CROSSING PARCEL W1A NW CORNER OF GREEN VALLEY RANCH BLVD & TOWER RD PREPARED FOR EVC-WDG TOWER II, LLC 4201 E YALE AVE, SUITE 140 DENVER, CO 80222 CITY AND COUNTY OF DENVER PUBLIC WORKS DEVELOPMENT ENGINEERING SERVICES PM PROJECT NO. 2019PM0000456 AMENDMENT TO PM PROJECT NO. 2018PM0000677 SUBMITTAL PBG WEST 4TH AMENDMENT DRAWN BY: CHECKED BY: MRB PROJECT NO.: 19-064-009 REVISIONS DATE 01/10/2020 SHEET TITLE DETAILS SHEET INFORMATION R CONSTRUCTION SET Know what's below. C-5.2 Callbefore you dig. 10 Of 10 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 1 A001 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. BUILDING AREA: 2,343 SF SITE AREA: 0.58 ACRES PARCEL: W1A DESCRIPTION PERMIT SET DATE 27 DEC 2019 VAN # 1 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 2/17/2020 10:25:53 AM Project Number: 1 SITE PLAN SCALE: 1/16" = 1'-0" SITE PLAN A000 RE: PLAN FOR DIMENSIONS EQ EQ CONCRETE DOME PAINT ALL EXPOSED STEEL, PT-1, TYP 4" DIAMETER STANDARD STEEL PIPE FILLED WITH CONCRETE 3' - 6" 6" HSS 5 X 3 X 3/16, TYP AT TOP RAIL 5' - 6" CONCRETE PAVING, RE: CIVIL OWNER EVC-WDG TOWER II, LLC 3' - 0" 6" 6" 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 12" DIAMETER FOOTING ARCHITECT CHORD DESIGN STUDIO, P.C. HSS 3 X 3 X 3/16, TYP STANLEY 1010 18" CANE BOLT (OR EQUAL), DRILL HOLE IN PAVING FOR BOLT, TYP OF 4 1425 MARKET STREET SUITE 220 DENVER, CO 80202 4" FIRESTONE UNA-CLAD VR-CLASSIC OMEGA 22 GA STEEL PANEL WITH KYNAR FINISH (MATCH P-1). ATTACH TO TOP AND BOTTOM RAIL @ 16" OC, ATTACH TO DIAGONAL AND VERTICAL RAILS @ 24" OC HEAVY DUTY CASTERS, TYP OF 4 t: 303.694.2445 1' - 0" CIVIL 5 TRASH ENCLOSURE - GATE ELEVATION 4 SCALE: 1/2" = 1'-0" RIDGETOP ENGINEERING SECTION DETAIL AT PIPE BOLLARD 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 SCALE: 3/4" = 1'-0" STRUCTURAL PORTIS STRUCTURAL DESIGN 4" DIA CONCRETE FILLED STANDARD STEEL PIPE BOLLARD, TYP 6" MEP 1/4" 1/4" 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 2' - 0" FRAME BELOW STOP BLOCK WELDED TO STATIONARY 6" PIPE GIVEN & ASSOCIATES EQ 8" STOP BLOCK WELDED TO ROTATING PORTION OF 8" PIPE. LOCATE TO ALLOW GATE TO SWING OUT 105° PLAN VIEW EQ TRASH ENCLOSURE WALL 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 TS4 x 3 x 3/16 6" STEEL PIPE FILLED w/ CONCRETE CUT SECTION OF TS4 x 3 x 3 x 3/16 AT RADIUS TO MATCH 8" PIPE HINGE 8" DIAMETER DOUBLE EXTRA STRONG PIPE 8" DIAMETER DOUBLE STRONG PIPE NOT WELDED TO 6" PIPE, FREE TO ROTATE 5' - 10 3/8" CUT SECTION OF TS4 x 3 x 3 x 3/16 AT RADIUS TO MATCH 8" PIPE HINGE 6" STEEL PIPE FILLED w/ CONCRETE 3 1/2" TS4 x 3 x 3/16 PRECAST CONCRETE CAP 1/4" 6" 1/4" 1/4" ZERK GREASE FITTING, TYP. 1/4" TYP TYP 1/4" STEEL END PLATE w/ 1/8" HOLES FOR DRAINAGE ISOLATION JOINT RE: STRUCTURAL FOR REINFORCEMENT SLOPE TO DRAIN (RE: CIVIL) 5 A001 # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 8' - 0" 6" PAVING, RE: CIVIL 3' - 0" 1/4" 1/4" THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. 20' - 0" 8" DIAMETER DOUBLE STRONG PIPE NOT WELDED TO 6" PIPE, FREE TO ROTATE CLEAR PENETRATING SEALER ALL EXPOSED CMU SURFACES, PAINT 6" ELEVATION VIEW ABOVE SLAB COPYRIGHT: 2019 TYP 5' - 10 3/8" CEMENTITIOUS HARDCOAT STUCCO, PT-1 (4) #5 VERT. SECTION VIEW BELOW SLAB STARBUCKS CORE & SHELL CONCRETE CURB, FOUNDATION AND SLAB, RE: STRUCTURAL 8" 2/17/2020 10:56:53 AM 6" 18" DIAMETER CONCRETE FOOTING 8' - 0" 12' - 0" EQ 6" A001 EQ 2 8" 2' - 0" 8" #3 HOOPS AT 18" O.C. PROVIDE DRILLED HOLES IN PAVING FOR CANE BOLT 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: SITE DETAILS 1' - 6" A001 3 TRASH ENCLOSURE - GATE HINGE DETAIL SCALE: 1 1/2" = 1'-0" 2 TRASH ENCLOSURE - SECTION SCALE: 3/4" = 1'-0" 1 TRASH ENCLOSURE - PLAN SCALE: 1/2" = 1'-0" 19022 PAINT ALL STEEL PT-1 20' - 0" EQ EQ EQ 1' - 1" 3X2X.125 HSS TUBE 2X2X.125 HSS TUBE FRAME, TYP. SPACE VERTICAL POSTS 4'-0" MAX 1/2" 4" 8' - 0" 2" X 6" WELDED WIRE MESH 1' - 6" 5" CEMENTITIOUS HARDCOAT STUCCO (COLOR TO MATCH PT-1) 1/2" 1/2" THICK STEEL BASEPLATE EQ OWNER 5" EQ 2" 2X2X.125" HSS TUBE FRAME 1/2" HILTI KB-3 EXPANSION ANCHOR, EA SIDE, WITH 3 1/2" MIN EMBEDMENT 1/4" STEEL ANGLE FRAME, WELD TO HSS FRAME EVC-WDG TOWER II, LLC 1/2" HILTI KB-3 EXPANSION ANCHOR, EA SIDE, WITH 3 1/2" MIN EMBEDMENT 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT 5" X 2" X 1/2" THICK STEEL BASEPLATE 7 STUCCO CONTROL JOINT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 PATIO RAILING BASEPLATE 6 SCALE: 6" = 1'-0" PATIO RAILING SECTION 5 SCALE: 1 1/2" = 1'-0" TRASH ENCLOSURE - ELEVATION t: 303.694.2445 SCALE: 1/2" = 1'-0" CIVIL RIDGETOP ENGINEERING 2' - 2" 2' - 2" 1' - 4" EQ PT-2 EQ 4" PAINTED STEEL CAP, WELD TO STRUCTURAL HSS TUBE STEEL BEAM PT-2 STRUCTURAL HSS TUBE STEEL BEAM, RE: STRUCTURAL 3 00° 45. HSS TUBE STEEL COLUMNS, PAINT TO MATCH STEEL CAP, RE: STRUCTURAL PORTIS STRUCTURAL DESIGN COORDINATE REQUIRED CLEARANCE WITH SIGN COMPANY HSS TUBE STEEL BEAM, RE: STRUCTURAL A002 SIGN CABINET BY SIGN COMPANY IN CORE AND SHELL SCOPE (GC SHALL INCLUDE IN BUDGET AND COORDINATE CONSTRUCTION WITH SIGN COMPANY) 4 5X5X1/4 HSS TUBE STEEL, PAINT TO MATCH STEEL CAP A002 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 5' - 8" 3' - 8" HSS TUBE STEEL COLUMN BEYOND, RE: STRUCTURAL EQ SIGN CABINET BY SIGN COMPANY IN CORE AND SHELL SCOPE (GC SHALL INCLUDE IN BUDGET AND COORDINATE CONSTRUCTION WITH SIGN COMPANY) SIGN CABINET BEYOND EQ MEP 1' - 4" EQ 1' - 4" 4" PAINTED STEEL CAP, WELD TO STRUCTURAL HSS TUBE STEEL BEAM 2' - 4" EQ 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 8" 6" 9' - 10" 10" 10" PRECAST CONCRETE WALL CAP (COLOR TO BE SELECTED BY MANUFACTURER'S STANDARD RANGE) - SLOPE TO DRAIN GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 3' - 0" 13' - 4" PRECAST CONCRETE WALL CAP (COLOR TO BE SELECTED BY MANUFACTURER'S STANDARD RANGE) - SLOPE TO DRAIN 2 MONUMENT SIGN - PLAN SCALE: 1/2" = 1'-0" BRICK VENEER TO MATCH MA-1 BUILDING BRICK VENEER TO MATCH MA-1 BUILDING 4" PAINTED STEEL CAP PT-2 6" X 8" X 16" REINFORCED CMU, RE: STRUCTURAL 6' - 0" 6" X 8" X 16" REINFORCED CMU, RE: STRUCTURAL CONCRETE FOUNDATION, RE: STRUCTURAL 5X5X1/4 HSS TUBE STEEL, PAINT TO MATCH STEEL CAP SIGN CABINET BY SIGN COMPANY IN CORE AND SHELL SCOPE (GC SHALL INCLUDE IN BUDGET AND COORDINATE CONSTRUCTION WITH SIGN COMPANY) 9' - 10" 3' - 0" PRECAST CONCRETE WALL CAP (COLOR TO BE SELECTED BY MANUFACTURER'S STANDARD RANGE) - SLOPE TO DRAIN 8' - 0" STARBUCKS CORE & SHELL 5' - 8" 2' - 4" RE: STRUCTURAL RE: STRUCTURAL 4" 2' - 4" DATE 27 DEC 2019 STARBUCKS SIGN PANEL 4" CONCRETE FOUNDATION, RE: STRUCTURAL DESCRIPTION PERMIT SET 12' - 0" EQ 5' - 8" CONDUIT FOR SIGN POWER, RE: ELECTRICAL STEEL EMBED PLATE, RE: STRUCTURAL THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 EQ 8' - 0" COPYRIGHT: 2019 PRECAST CONCRETE WALL CAP (COLOR TO BE SELECTED BY MANUFACTURER'S STANDARD RANGE) - SLOPE TO DRAIN EQ 12' - 0" 12' - 0" HSS TUBE STEEL BEAM, RE: STRUCTURAL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 BRICK VENEER TO MATCH BUILDING MA-1 2/17/2020 10:57:08 AM 4" Project Number: RE: STRUCTURAL CONCRETE FOUNDATION, RE: STRUCTURAL RE: STRUCTURAL SITE DETAILS 13' - 4" 4 MONUMENT SIGN - SECTION SCALE: 3/4" = 1'-0" 3 MONUMENT SIGN - SECTION SCALE: 3/4" = 1'-0" 1 MONUMENT SIGN - ELEVATION SCALE: 1/2" = 1'-0" A002 19022 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 29' - 3 3/4" 3' - 10" 19' - 1 7/8" ARCHITECT 2" 6' - 3 7/8" CHORD DESIGN STUDIO, P.C. 2' - 3 7/8" 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 2" CIVIL 10' - 0" 10" TYP. @ OVERPOUR RE: STRUCT 3' - 8 1/8" 16' - 0" 8" TYP. @ FRAMING RE: STRUCT. RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL 3' - 4" 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 2' - 11 7/8" 40' - 0" PORTIS STRUCTURAL DESIGN 2" MEP 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 2' - 11 7/8" 71' - 11 3/4" 19' - 4" 25' - 3 3/4" GIVEN & ASSOCIATES 5' - 4" COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. 14' - 8 1/4" 15' - 3 3/4" 3' - 8 1/8" 3' - 11" # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 3' - 8 1/8" 7' - 4" 2" 7" STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2" 8" 2" 2' - 3 7/8" 12' - 0" 16' - 8" 2" 16' - 7 3/4" 2' - 3 7/8" 5' - 4" 9' - 4" 2/17/2020 10:25:55 AM 11 7/8" 14' - 0" 1' - 8 1/8" 1' - 7 7/8" 12' - 0" Project Number: 19022 1' - 7 7/8" 17' - 3 3/4" FOUNDATION PLAN 29' - 3 3/4" 1 FOUNDATION PLAN SCALE: 3/16" = 1'-0" A100 38' - 8" 5' - 4" 30' - 0" 3' - 4" A203 30' - 0" OWNER 2 EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 100C 3' - 4" 3' - 4" 6' - 2" 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PERIMETER SLAB, RE: STRUCTURAL 40' - 0" 1' - 0" 10' - 8" RIDGETOP ENGINEERING 3' - 4" 4' - 0" TYP PORTIS STRUCTURAL DESIGN CANOPY DOWNSPOUT 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 1 MEP 1 GIVEN & ASSOCIATES 26' - 0" 21' - 4" A203 19' - 4" PREFINISHED SCUPPER AND CONDUCTOR HEAD W/ 4" DOWNSPOUT AND ADJACENT OVERFLOW SCUPPER. DOWNSPOUT CONNECTS TO BELOW GRADE STORM SEWER LINE, RE: CIVIL, TYP OF 2 t: 303.694.2445 CIVIL 2' - 4" RTU 1,700 LBS 1425 MARKET STREET SUITE 220 DENVER, CO 80202 16' - 0" 10' - 0" CHORD DESIGN STUDIO, P.C. 3' - 0 1/2" 11' - 8" ARCHITECT ALIGN W/ TRIM @ JAMB 19' - 6" 10' - 7" 11' - 4" 10 A605 1 A252 1/4" / 1'-0" A202 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 2' - 0" 10' - 8" 3 2' - 0" 2' - 4" 3' - 11" 5' - 4" 3' - 0 1/2" 3' - 4" 7' - 4" A252 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 3 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 2' - 8" 3' - 4" 5' - 4" 12' - 0" 6' - 8" 17' - 4" 8' - 0" 7" CANOPY DOWNSPOUT 16' - 8" 12' - 8" 15' - 8" 11' - 6" 2 A604 1 A604 2' - 4" 3 A604 2' - 8" 1' - 0" A606 2 14' - 0" 9' - 0" 16' - 0" 1 ALIGN W/ TRIM @ JAMB 7' - 3" 7' - 8 1/2" 1' - 10" 2' - 4" 3' - 0 1/2" 11' - 1" COPYRIGHT: 2019 5' - 0" RTU 1,700 LBS 3 ALIGN W/ TRIM @ JAMB 5' - 0" 7' - 11" 19' - 8" 100A 1' - 4" 2' - 0" 3' - 4" 1' - 10" A603 73' - 4" 72' - 8" 5 100B STARBUCKS CORE & SHELL 1 A251 9' - 4" 9' - 11" 2/17/2020 10:25:57 AM ALIGN W/ TRIM @ JAMB 1' - 4" 15' - 4" 1' - 4" 1' - 0 1/2" 1' - 4" 2' - 0" 14' - 0" 2' - 0" 3" X 3" CANOPY DOWNSPOUT, RE: CIVIL FOR CONTINUATION AND PLUMBING FOR FLOW CALCULATIONS, TYP OF 3 30' - 0" Project Number: 7 A002 SCALE: 3/16" = 1'-0" 19022 2 FLOOR PLAN & ROOF PLAN A202 2 ROOF PLAN 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 6 A002 1 FLOOR PLAN SCALE: 3/16" = 1'-0" A101 OWNER 1' - 4" EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 EQ EQ 1' - 4" 1' - 4" ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL EQ EQ RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES EQ EQ EQ EQ 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 EQ THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL EQ EQ EQ # 1 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 EQ EQ EQ EQ 2/17/2020 10:25:58 AM Project Number: 19022 REFLECTED CEILING PLAN 1 REFLECTED CEILING PLAN SCALE: 3/16" = 1'-0" A151 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:07 AM Project Number: 19022 BUILDING PERSPECTIVES A200 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:14 AM Project Number: 19022 BUILDING PERSPECTIVES A201 EXTERIOR ELEVATION NOTES: MAXIMUM FENESTRATION CALCULATIONS (IECC C402.4) 1. STOREFRONT GLAZING SPECIFICATIONS: - ALL STOREFRONT GLAZING - BLACK ANODIZED, U.N.O. - TEMPER ALL EXTERIOR STOREFRONT GLAZING - CLEAR LOW-E GLAZING WITH VLT 65% OR GREATER - MIN GLAZING U-VALUE = 0.38 / MIN SHGC = 0.40 - BASIS OF DESIGN: KAWNEER (4 1/2" DEPTH WITH 2" SIGHT LINE) EAST ELEVATION SOLID WALL AREA: 1,705 S.F. FENESTRATION: 552 S.F. PERCENTAGE: 32.4% NORTH ELEVATION SOLID WALL AREA: 880 S.F. FENESTRATION: 10 S.F. PERCENTAGE: 1.1% SOUTH ELEVATION: SOLID WALL AREA: 891 S.F. FENESTRATION: 264 S.F. PERCENTAGE: 29.6% WEST ELEVATION: SOLID WALL AREA: 1,596 S.F. FENESTRATION: 98 S.F. PERCENTAGE: 6.1% 32.4 + 1.1 + 29.6 + 6.1 = 69.2/4 = 17.3% TOTAL FENESTRATION 3 FINISHES 2. ALL EXPOSED EXTERIOR STEEL AND HM DOORS TO BE PAINTED PT-1, U.N.O. 3. ALL COPING ON WALL ASSEMBLIES TO MATCH WALL MATERIAL. MA-1 MASONRY 4. ALL MFC LAP SIDING TO BE HARDIE BOARD ARTISAN SMOOTH FINISH, 5/8" X 7 1/4" PLANKS (6" EXPOSURE) PREFINISHED TO MATCH SPECIFIED COLOR. BUTT JOINTS BETWEEN CONSECUTIVE COURSES SHALL BE STAGGERED 24" MINIMUM IN A PROGRESSIVE STAGGER PATTERN SO THAT JOINTS DO NOT ALIGN WITHIN 5 COURSES ABOVE & BELOW EACH JOINT. PT-1 PAINT MATERIAL BRICK VENEER MATERIAL PRO-INDUSTRIAL ACRYLIC MANUFACTURER SUMMIT BRICK OR APPROVED EQUIV. MANUFACTURER SHERWIN WILLIAMS STYLE-COLOR MODULAR - 75% LIGHT PEWTER & 25% FOSSIL GRAY STYLE-COLOR SW 7510 CHATEAU BROWN NOTE RUNNING BOND NOTE 5. ALL EXPOSED PIPING AND CONDUIT SHALL BE PAINTED TO MATCH ADJACENT WALL MATERIAL. 6. PROVIDE SOLID BLOCKING IN WALL FOR BUILDING MOUNTED FIXTURES AND SIGNAGE AS REQUIRED. HD-1 FIBER CEMENT SIDING PT-2 PAINT MATERIAL MFC LAP SIDING MATERIAL PRO-INDUSTRIAL ACRYLIC 7. FUTURE SIGNAGE CONDUIT STUB-OUT LOCATIONS TO BE INSTALLED AND SEALED BY GC. COORDINATE EXACT STUB-OUT LOCATIONS WITH TENANT'S SIGN CONTRACTOR MANUFACTURER JAMES HARDIE MANUFACTURER SHERWIN WILLIAMS STYLE-COLOR ARTISAN, SMOOTH - SHERWIN WILLIAMS - SW 7510 CHATEAU BROWN STYLE-COLOR SW 6990 CAVIAR 8. CONTINUE EXTERIOR CLADDING AT PARAPET RETURNS. NOTE OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 NOTE ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 1 A251 T.O. PARAPET 125' - 0" t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN MA-1 HD-1 MA-1 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MA-1 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 PT-2 PT-2 CC DD PT-2 LEVEL 01 100' - 0" 6 MA-1 A002 2 2 1 A252 A252 SOUTH ELEVATION SCALE: 1/4" = 1'-0" T.O. PARAPET 125' - 0" MA-1 HD-1 MA-1 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 3 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 HD-1 STARBUCKS CORE & SHELL PT-2 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 PT-2 2/17/2020 10:26:15 AM PT-2 Project Number: PT-2 EE FF GG 19022 HH BUILDING ELEVATIONS MA-1 MA-1 MA-1 MA-1 LEVEL 01 100' - 0" 3 PT-2 1 EAST ELEVATION SCALE: 1/4" = 1'-0" A202 EXTERIOR ELEVATION NOTES: MAXIMUM FENESTRATION CALCULATIONS (IECC C402.4) 1. STOREFRONT GLAZING SPECIFICATIONS: - ALL STOREFRONT GLAZING - BLACK ANODIZED, U.N.O. - TEMPER ALL EXTERIOR STOREFRONT GLAZING - CLEAR LOW-E GLAZING WITH VLT 65% OR GREATER - MIN GLAZING U-VALUE = 0.38 / MIN SHGC = 0.40 - BASIS OF DESIGN: KAWNEER (4 1/2" DEPTH WITH 2" SIGHT LINE) EAST ELEVATION SOLID WALL AREA: 1,705 S.F. FENESTRATION: 552 S.F. PERCENTAGE: 32.4% NORTH ELEVATION SOLID WALL AREA: 880 S.F. FENESTRATION: 10 S.F. PERCENTAGE: 1.1% SOUTH ELEVATION: SOLID WALL AREA: 891 S.F. FENESTRATION: 264 S.F. PERCENTAGE: 29.6% WEST ELEVATION: SOLID WALL AREA: 1,596 S.F. FENESTRATION: 98 S.F. PERCENTAGE: 6.1% 32.4 + 1.1 + 29.6 + 6.1 = 69.2/4 = 17.3% TOTAL FENESTRATION 3 FINISHES 2. ALL EXPOSED EXTERIOR STEEL AND HM DOORS TO BE PAINTED PT-1, U.N.O. 3. ALL COPING ON WALL ASSEMBLIES TO MATCH WALL MATERIAL. MA-1 4. ALL MFC LAP SIDING TO BE HARDIE BOARD ARTISAN SMOOTH FINISH, 5/8" X 7 1/4" PLANKS (6" EXPOSURE) PREFINISHED TO MATCH SPECIFIED COLOR. BUTT JOINTS BETWEEN CONSECUTIVE COURSES SHALL BE STAGGERED 24" MINIMUM IN A PROGRESSIVE STAGGER PATTERN SO THAT JOINTS DO NOT ALIGN WITHIN 5 COURSES ABOVE & BELOW EACH JOINT. MASONRY PAINT PT-1 MATERIAL BRICK VENEER MATERIAL PRO-INDUSTRIAL ACRYLIC MANUFACTURER SUMMIT BRICK OR APPROVED EQUIV. MANUFACTURER SHERWIN WILLIAMS STYLE-COLOR MODULAR - 75% LIGHT PEWTER & 25% FOSSIL GRAY STYLE-COLOR SW 7510 CHATEAU BROWN NOTE RUNNING BOND NOTE 5. ALL EXPOSED PIPING AND CONDUIT SHALL BE PAINTED TO MATCH ADJACENT WALL MATERIAL. 6. PROVIDE SOLID BLOCKING IN WALL FOR BUILDING MOUNTED FIXTURES AND SIGNAGE AS REQUIRED. HD-1 FIBER CEMENT SIDING PAINT PT-2 MATERIAL MFC LAP SIDING MATERIAL PRO-INDUSTRIAL ACRYLIC 7. FUTURE SIGNAGE CONDUIT STUB-OUT LOCATIONS TO BE INSTALLED AND SEALED BY GC. COORDINATE EXACT STUB-OUT LOCATIONS WITH TENANT'S SIGN CONTRACTOR MANUFACTURER JAMES HARDIE MANUFACTURER SHERWIN WILLIAMS STYLE-COLOR ARTISAN, SMOOTH - SHERWIN WILLIAMS - SW 7510 CHATEAU BROWN STYLE-COLOR SW 6990 CAVIAR 8. CONTINUE EXTERIOR CLADDING AT PARAPET RETURNS. NOTE OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 NOTE ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 1 7 A605 A251 CIVIL T.O. PARAPET 125' - 0" RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MA-1 HD-1 MA-1 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 JJ 3 MA-1 COPYRIGHT: 2019 LEVEL 01 100' - 0" PT-2 PT-1 2 NORTH ELEVATION SCALE: 1/4" = 1'-0" T.O. PARAPET 125' - 0" 1 2 A252 A252 HD-1 PT-2 2/17/2020 10:26:16 AM DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 11' - 4" PT-2 AA # 1 3 STARBUCKS CORE & SHELL HD-1 MA-1 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. BB Project Number: 19022 BUILDING ELEVATIONS MA-1 MA-1 LEVEL 01 100' - 0" PT-2 1 WEST ELEVATION SCALE: 1/4" = 1'-0" A203 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 1 2 A252 A252 COPYRIGHT: 2019 1 A301 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. T.O. PARAPET 125' - 0" 2 A301 # 1 2 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 07 FEB 2020 STARBUCKS CORE & SHELL GROUNDWATER FOUND AT 32.0 FEET BELOW EXISTING GRADE (5353.0) ALL FOOTINGS TO BE INSTALLED 3'-0" BELOW FINISH GRADE Project Number: LEVEL 01 100' - 0" 3' - 0" 2/17/2020 10:26:17 AM 2 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 100'-0" = 5385.0 1 LONGITUDINAL SECTION SCALE: 1/4" = 1'-0" 2 19022 BUILDING SECTIONS A251 1 A251 5 A603 T.O. PARAPET 125' - 0" 2 A302 1 A302 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL 2 2 RIDGETOP ENGINEERING GROUNDWATER FOUND AT 32.0 FEET BELOW EXISTING GRADE (5353.0) ALL FOOTINGS TO BE INSTALLED 3'-0" BELOW FINISH GRADE 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 3' - 0" 3' - 0" LEVEL 01 100' - 0" STRUCTURAL PORTIS STRUCTURAL DESIGN 100'-0" = 5385.0 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 2 MEP GIVEN & ASSOCIATES 2 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 TRANSVERSE SECTION - DRIVE THROUGH SCALE: 1/4" = 1'-0" 3 A301 1 A251 COPYRIGHT: 2019 T.O. PARAPET 125' - 0" 2 A301 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. SIM WOOD KICKER, RE: STRUCTURAL # 1 2 DASH INDICATES BOTTOM OF MASONRY AT ROOF LEVEL DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 07 FEB 2020 WOOD KICKER, RE: STRUCTURAL STARBUCKS CORE & SHELL 2 2 GROUNDWATER FOUND AT 32.0 FEET BELOW EXISTING GRADE (5353.0) ALL FOOTINGS TO BE INSTALLED 3'-0" BELOW FINISH GRADE 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 3' - 0" 3' - 0" 2/17/2020 10:26:18 AM LEVEL 01 100' - 0" 100'-0" = 5385.0 Project Number: 19022 2 BUILDING SECTIONS 1 TRANSVERSE SECTION - ENTRY SCALE: 1/4" = 1'-0" A252 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 5 A601 1425 MARKET STREET SUITE 220 DENVER, CO 80202 T.O. PARAPET 125' - 0" t: 303.694.2445 CIVIL 2 A601 RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 4 A601 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2019 1 A602 1 A602 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 3 A601 STARBUCKS CORE & SHELL 1 A601 1 A601 LEVEL 01 100' - 0" LEVEL 01 100' - 0" LEVEL 01 100' - 0" 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 2/17/2020 10:26:19 AM Project Number: WALL SECTIONS 3 WALL SECTION - STOREFRONT AT BRICK - HIGH SCALE: 1/2" = 1'-0" 2 WALL SECTION - SIDING OVER BRICK SCALE: 1/2" = 1'-0" 1 WALL SECTION - STOREFRONT AT BRICK - LOW SCALE: 1/2" = 1'-0" A301 19022 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 2 A601 SIM 4 A601 STRUCTURAL PORTIS STRUCTURAL DESIGN 8"MIN. 121' - 8" SIM 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 LINE OF ROOFING TRANSITION ON NORTH AND SOUTH WING WALLS MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 2 A602 3 A602 COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 2 A603 DESCRIPTION PERMIT SET DATE 27 DEC 2019 1 A603 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 1 A601 3 A601 LEVEL 01 100' - 0" LEVEL 01 100' - 0" 2/17/2020 10:26:20 AM Project Number: WALL SECTIONS A302 2 WALL SECTION - DRIVE-THROUGH SCALE: 1/2" = 1'-0" 1 WALL SECTION - STOREFRONT AT SIDING SCALE: 1/2" = 1'-0" 19022 WINDOW NOTES: DOOR SCHEDULE DOOR NUMBER FIRE RATING TYPE WIDTH 100A 100B 100C - A B C 6' - 0" 3' - 0" 3' - 6" DOOR HEIGHT MATERIAL 8' - 0" 8' - 0" 7' - 0" AL AL HM FRAME MATERIAL FINISH FINISH AN AN PT-1 AL AL HM 01 02 03 STOREFRONT SPECIFICATIONS: A. FINISH: BLACK ANODIZED, U.N.O. B. TEMPER ALL EXTERIOR STOREFRONT GLAZING T C. CLEAR LOW-E GLAZING WITH VLT 65% OR GREATER D. REFER TO CODE ANALYSIS FOR IECC COMPLIANCE REQUIREMENTS FOR FENESTRATIONS. E. BASIS OF DESIGN: KAWNEER TRIFAB 451T VERAGLAZE (4 1/2" DEPTH WITH 2" SIGHT LINE) NOTES PAINT TO MATCH ADJACENT WALL 4" 2. 3. 4. RE: SCHEDULE 5. 6. ALL DOORS TO PROVIDE 32" MIN CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION U.N.O. SEE SCHEDULE FOR FINISH INFORMATION. SWINGING EXTERIOR DOORS: HM = 16 GA. EXTERIOR DOOR LOCK TO HAVE 1" BOLT PROTECTION (IF APPLICABLE) ONE MOTION, LEVER HANDLE, DEADBOLT FUNCTION REQUIRED SOLID STEEL CYLINDER GUARD/APPROVED ESCUTCHEON REQUIRED. NON-REMOVABLE EXTERIOR HINGE PINS (NRP) REQUIRED ON OUTSWINGING DOORS. OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 10" 10" A MEDIUM STILE ALUMINUM ENTRANCE DOORS BY STOREFRONT MANUFACTURER 1. RE: SCHEDULE RE: SCHEDULE RE: SCHEDULE RE: SCHEDULE RE: SCHEDULE 2 1/2" TYP DOOR NOTES 2 1/2" TYP DOOR TYPES AN AN PT-1 HARDWARE SET B C MEDIUM STILE ALUMINUM ENTRANCE DOOR BY STOREFRONT MANUFACTURER HOLLOW METAL FRAME WITH HOLLOW METAL DOOR ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 HARDWARE SETS t: 303.694.2445 HARDWARE NOTES CIVIL SET 01: EXTERIOR DOUBLE STOREFRONT DOORS - (KAWNEER 350) 1 RIM CYLINDER 2 PULLS 6 BUTT HINGES (4 1/2" X 4") 1 ASTRAGAL 2 EXIT DEVICES 2 SURFACE CLOSERS 2 OVERHEAD STOPS 1 THRESHOLD 2 WEATHER STRIPPING 2 DOOR SWEEPS 1. C953 9266 300 SERIES STANDARD 24-C SERIES SC-80 100S 195 STANDARD STANDARD FALCON IVES KAWNEER KAWNEER FALCON FALCON GLYNN JOHNSON PEMKO KAWNEER KAWNEER 613 630 ------622 622 ---D ------- FALCON IVES KAWNEER FALCON FALCON GLYNN JOHNSON PEMKO KAWNEER KAWNEER 613 630 ---622 622 ---D ------- 2. 3. 3 C953 9266 300 SERIES 24-C SERIES SC-80 100S 195 STANDARD STANDARD 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN GC TO VERIFY HARDWARE FUNCTION AND KEYING REQUIREMENTS WITH OWNER PRIOR TO ORDERING SET 02: EXTERIOR SINGLE STOREFRONT DOORS - (KAWNEER 350) 1 RIM CYLINDER 1 PULLS 3 BUTT HINGES (4 1/2" X 4") 1 EXIT DEVICE 1 SURFACE CLOSER 1 OVERHEAD STOPS 1 THRESHOLD 1 WEATHER STRIPPING 1 DOOR SWEEPS RIDGETOP ENGINEERING THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS (22 N). DOOR HANDLES, PULL, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 1/2 INCH IN HEIGHT ABOVE THE FINISHED FLOOR. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4 INCH AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 SET 03: EXTERIOR SERVICE DOOR - (42" WIDE DOOR) 3 BUTT HINGES 1 7-PIN CORE COMBINATED "A" KEYWAY 1 DOOR ALARM EXIT DEVICE 1 CLOSER 1 KICKPLATE 10x40 1 RAIN DRIP 1 WEATHER STRIP 1 SWEEP 1 DOOR SPY 1 DOOR BELL 1 STOP W/HOOK 1 THRESHOLD FBB191 5x4.5NP C607 I/O 2000L-031C 8916 AF89P K1050 B4E 16A 46" 137NA 17.5' 42x84 C607A - 42" DS-6 MCV309NWHGL 473 325 HALF SADDLE STANLEY FALCON SUR-LOCK DORMA ROCKWOOD NATIONAL GUARD NATIONAL GUARD NATIONAL GUARD SECURITY PRODUCTS NUTONE ROCKWOOD NATIONAL GUARD 630 626 --689 630 A A A SILVER 10' - 0" EQ 19' - 4" EQ 6' - 3" EQ 7' - 4" EQ EQ EQ EQ EQ ----- COPYRIGHT: 2019 11' - 4" THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. 8' - 1" 11' - 4" 8' - 1" 8' - 1" 4' - 8" 11' - 4" 2' - 0" # 1 3 3 DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 3 JJ WINDOW TYPE HH WINDOW TYPE SCALE: 1/4" = 1'-0" 12' - 0" 4' - 0" 4' - 0" GG WINDOW TYPE SCALE: 1/4" = 1'-0" 14' - 0" EQ 4' - 0" 9' - 4" EQ FF WINDOW TYPE SCALE: 1/4" = 1'-0" 4' - 8" SCALE: 1/4" = 1'-0" 6' - 8" 4' - 8" 3' - 4" STARBUCKS CORE & SHELL 3' - 4" 1' - 4" ALIGN TOP OF MULLION WITH TOP OF ADJACENT DRIVE-THRU WINDOW 3' - 8" 4' - 11" 3' - 4" 3' - 0" AFF 11' - 4" 4' - 0" READY ACCESS 275 SERVICE WINDOW w/ AA300 PASS-THRU AIR CURTAIN 8' - 1" 11' - 4" 8' - 1" 8' - 1" 2/17/2020 10:26:21 AM 11' - 4" 8' - 0" 5' - 0" EE WINDOW TYPE SCALE: 1/4" = 1'-0" DD WINDOW TYPE SCALE: 1/4" = 1'-0" CC WINDOW TYPE SCALE: 1/4" = 1'-0" BB WINDOW TYPE SCALE: 1/4" = 1'-0" AA WINDOW TYPE SCALE: 1/4" = 1'-0" 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: 19022 DOOR AND WINDOW SCHEDULES A501 11 3/8" SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS IECC REQUIREMENTS 7 1/4" SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE 4 1/8" 11 3/4" 1. REFER TO MATERIAL SPECIFICATIONS (G SHEETS) FOR INSULATION AND AIR BARRIER TYPES AND TO THE CODE SUMMARY FOR R-VALUE REQUIREMENTS 4 1/2" CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF 2. THE AIR BARRIER SHALL BE CONTINUOUS FOR ALL ASSEMBLIES THAT ARE THE THERMAL ENVELOPE OF THE BUILDING AND ACROSS THE JOINTS AND ASSEMBLIES. 121' - 8" 3. AIR BARRIER JOINTS AND SEAMS SHALL BE SEALED, INCLUDING SEALING TRANSITIONS IN PLACES AND CHANGES IN MATERIALS. THE JOINTS AND SEALS SHALL BE SECURELY INSTALLED IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND MECHANICAL VENTILATION. CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE SEALANT, TYP. BOTH SIDES SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS FULLY ADHERED ROOF MEMBRANE ON 5/8" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP OVER TOP OF PARAPET FULLY ADHERED ROOF MEMBRANE ON 5/8" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET SEALANT, TYP. BOTH SIDES HARDI TRIM BOARD, SEAL PERIMETER 4. PENETRATIONS OF THE AIR BARRIER SHALL BE CAULKED, GASKETED OR OTHERWISE SEALED IN A MANNER COMPATIBLE WITH THE CONSTRUCTION MATERIALS AND LOCATION. JOINTS AND SEALS ASSOCIATED WITH PENETRATIONS SHALL BE SEALED IN THE SAME MANNER OR TAPED OR COVERED WITH MOISTURE VAPORPERMEABLE WRAPPING MATERIAL. SEALING MATERIALS SHALL BE APPROPRIATE TO THE CONSTRUCTION MATERIALS BEING SEALED AND SHALL BE SECURELY INSTALLED AROUND THE PENETRATION SO AS NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR THE PENETRATIONS’ ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND MECHANICAL VENTILATION. SEALING OF CONCEALED FIRE SPRINKLERS, WHERE REQUIRED, SHALL BE IN A MANNER THAT IS RECOMMENDED BY THE MANUFACTURER. CAULKING OR OTHER ADHESIVE SEALANTS SHALL NOT BE USED TO FILL VOIDS BETWEEN FIRE SPRINKLER COVER PLATES AND WALLS OR CEILINGS. CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF 123' - 0" 7 1/4" FULLY ADHERED ROOF MEMBRANE OVER COVER BOARD, OVER RIGID INSULATION, OVER PLYWOOD DECK 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS FULLY ADHERED ROOF MEMBRANE OVER COVER BOARD, OVER RIGID INSULATION, OVER PLYWOOD DECK MA-1, RE: ELEVATIONS NOTES PLACE 2X8 FOR INSULATION STOP BETWEEN EACH STUD AT ROOF LINE PLACE 2X8 FOR INSULATION STOP BETWEEN EACH STUD AT ROOF LINE LAP MOISTURE BARRIER OVER PARAPET AND UNDER ROOF MEMBRANE WOOD FRAMING, RE: STRUCTURAL 1 1/2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 5. RECESSED LIGHTING FIXTURES SHALL COMPLY WITH SECTION C402.5.8. WHERE SIMILAR OBJECTS ARE INSTALLED THAT PENETRATE THE AIR BARRIER, PROVISIONS SHALL BE MADE TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER. 6. THE ABOVE NOTES APPLY TO ALL DETAILS SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF T.O. PARAPET 125' - 0" STEEL BEAM OCCURS AT SOUTH WALL ONLY, OTHER LOCATIONS ROOF BEARS ON WOOD LEDGER; RE: STRUCTURAL 1425 MARKET STREET SUITE 220 DENVER, CO 80202 HARDIE TRIM BOARD AT JAMB BEYOND WOOD TRUSS BRACE, RE: STRUCTURAL t: 303.694.2445 WOOD TRUSS, RE: STRUCTURAL CIVIL 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS ATTACHMENT PER CANOPY MANUFACTURER 3/4" VERTICAL WOOD FURRING STRIPS 7 1/4" 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 PORTIS STRUCTURAL DESIGN MOISTURE BARRIER, LAP OVER DRIP EDGE BELOW BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP 4 SECTION DETAIL - PARAPET SIDING SCALE: 1 1/2" = 1'-0" 2 SECTION DETAIL - PARAPET BRICK GIVEN & ASSOCIATES SCALE: 1 1/2" = 1'-0" 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 4 A603 FULLY ADHERED ROOF MEMBRANE ON 5/8" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET 4 1/8" RIDGETOP ENGINEERING STRUCTURAL INTERIOR SHEATHING BY TENANT SEALANT, TYP. BOTH SIDES 11 3/8" CHORD DESIGN STUDIO, P.C. WOOD FRAMING, RE: STRUCTURAL CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP OVER THE TOP OF THE PARAPET 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT HARDIE LAP SIDING, RE: SPEC. SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS EVC-WDG TOWER II, LLC MASONRY VENEER ADHESIVE WOOD LEGER AND TRUSS BRACE, RE: STRUCTURAL 3 OWNER 103' - 4" FULLY ADHERED ROOF MEMBRANE, WRAP OVER TOP OF PARAPET WOOD FRAMING, RE: STRUCTURAL MASONRY VENEER ADHESIVE PLYWOOD SHEATHING, RE: STRUCTURAL MA-1, RE: ELEVATIONS NOTES COPYRIGHT: 2019 BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS PARAPET BRACE, RE: STRUCTURAL THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 3 A603 COVER BOARD, OVER RIGID INSULATION, OVER PLYWOOD DECK. FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND FLASHING ABOVE # 1 3 INTERIOR SHEATHING BY TENANT DESCRIPTION PERMIT SET PERMIT SET DATE 27 DEC 2019 14 FEB 2020 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS PLACE 2X8 FOR INSULATION STOP BETWEEN EACH STUD AT ROOF LINE ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES MA-1, RE: ELEVATIONS NOTES CONCRETE SLAB ON GRADE ON WATER BARRIER, ON COMPACTED FILL PER THE GEOTECHNICAL REPORT, RE: STRUCTURAL 2 1/8" MASONRY VENEER ADHESIVE LEVEL 01 100' - 0" LEVEL 01 100' - 0" COMPRESSIBLE FILLER AND SEALANT, RE: CITY STANDARD DRAWING ON CIVIL DETAIL SHEET 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL WOOD FRAMING, RE: STRUCTURAL CONCRETE FOOTING AND FOUNDATION WALL, RE: STRUCTURAL 10" CONCRETE FOOTING AND FOUNDATION WALL, RE: STRUCTURAL WOOD TRUSS, RE: STRUCTURAL RE: STRUCTURAL BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS WOOD LEGER AND TRUSS BRACE, RE: STRUCTURAL 2/17/2020 10:26:23 AM ATTACHMENT PER CANOPY MANUFACTURER STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: SECTION DETAILS BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS INTERIOR SHEATHING BY TENANT A601 5 SECTION DETAIL - PARAPET BRICK HIGH SCALE: 1 1/2" = 1'-0" 3 SECTION DETAIL - FOUNDATION AT CURB SCALE: 1 1/2" = 1'-0" 1 SECTION DETAIL - FOUNDATION AT STOREFRONT SCALE: 1 1/2" = 1'-0" 19022 11 3/8" 7 1/4" 4 1/8" ATTACHMENT PER CANOPY MANUFACTURER WOOD FRAMING, RE: STRUCTURAL MA-1, RE: ELEVATIONS NOTES MASONRY VENEER ADHESIVE MASONRY VENEER ADHESIVE FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND OVER FLASHING BELOW BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP MESH BACKWRAP PROVIDE 1/4" CLEAR WEEP TUBES @ 12" O.C. IN GROUT JOINT 112' - 2" SLOPED PREFINISHED METAL DRIP EDGE SET IN SEALANT, LAP BEHIND MOISTURE BARRIER. PROVIDE 4" END DAMS W/ CONTINUOUS SEALANT 4 A602 SIM OPP OWNER MA-1, RE: ELEVATIONS NOTES EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 MESH BACKWRAP PREFINISHED BRAKE METAL INFILL FOR WIDTH OF CANOPY. ALIGN FACE OF BRAKE METAL W/ FACE OF BRICK. FINISH TO MATCH CANOPY SLOPED PREFINISHED METAL DRIP EDGE SET IN SEALANT, LAP BEHIND MOISTURE BARRIER. PROVIDE 4" END DAMS W/ CONTINUOUS SEALANT HIGH TEMP FLEXIBLE FLASHING MOISTURE BARRIER BEHIND BRAKE METAL. CONTINUE INTO WINDOW HEAD AND BEHIND FLASHING ABOVE ARCHITECT CHORD DESIGN STUDIO, P.C. HIGH TEMP FLEXIBLE FLASHING MOISTURE BARRIER BEHIND BRAKE METAL. CONTINUE INTO WINDOW HEAD AND BEHIND FLASHING ABOVE WOOD HEADER, RE: STRUCT. 2X10 WOOD BLOCKING 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 111' - 4" 1/2" PLYWOOD SHEATHING SEALANT, TYP. BOTH SIDES PREMANUFACTURED CANOPY ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES 1425 MARKET STREET SUITE 220 DENVER, CO 80202 PREFINISHED BRAKE METAL INFILL FOR WIDTH OF CANOPY. ALIGN FACE OF BRAKE METAL W/ FACE OF BRICK. FINISH TO MATCH CANOPY t: 303.694.2445 FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND FLEXIBLE FLASHING ABOVE 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 CIVIL RIDGETOP ENGINEERING 2" STRUCTURAL INTERIOR SHEATHING BY TENANT PORTIS STRUCTURAL DESIGN 4 ENLARGED SECTION DETAIL - CANOPY 2 SCALE: 3" = 1'-0" 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 SECTION DETAIL - CANOPY AT DRIVE-THROUGH SCALE: 1 1/2" = 1'-0" 11 3/4" 7 1/4" MEP 4 1/2" GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 INTERIOR SHEATHING BY TENANT 11 3/8" 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL 7 1/4" 4 1/8" 1 1/2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS WOOD FRAMING, RE: STRUCTURAL HARDIE TRIM BOARD AT JAMB BEYOND HARDIE LAP SIDING, RE: SPEC. COPYRIGHT: 2019 BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS MESH BACKWRAP 3/4" VERTICAL WOOD FURRING STRIPS MA-1, RE: ELEVATIONS NOTES MOISTURE BARRIER, LAP OVER DRIP EDGE BELOW 6" TYP. THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. MASONRY VENEER ADHESIVE BLOCKING AS REQUIRED # 1 BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS DESCRIPTION PERMIT SET DATE 27 DEC 2019 SEALANT, TYP. BOTH SIDES FLEXIBLE FLASHING OVER MOISTURE BARRIER FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND OVER FLASHING BELOW 6" 3/8" 4 7/8" 1 1/2" 20 GA, 3" X 3" GALVANIZED ANGLE 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 4 A602 2" 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL 135 .00 ° 3/4" HARDIE TRIM BOARD, SEAL PERIMETER 6" SLOPED PREFINISHED METAL DRIP EDGE SET IN SEALANT. PROVIDE 4" END DAMS W/ CONTINUOUS SEALANT TY P. 4' - 2 PREMANUFACTURED CANOPY 1/ 4" STARBUCKS CORE & SHELL PRE-FABRICATED SHUTTER STYLE CANOPY. 2"X2" VERTICAL AND KICKER, 1"X3" ON PERIMETER AND SLOPE SURFACE FASTEN INTO VERTICAL HARDIE BOARD TRIM AT JAMB BEYOND 111' - 4" ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES 2/17/2020 10:26:24 AM 60 Project Number: .00 ° SEALANT, TYP. BOTH SIDES 108' - 0" 2 1/8" 3 SECTION DETAIL - AWNING AT STOREFRONT 1 SECTION DETAIL - CANOPY AT ENTRY SCALE: 1 1/2" = 1'-0" SECTION DETAILS INTERIOR SHEATHING BY TENANT ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES SCALE: 1 1/2" = 1'-0" 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 A602 19022 11 3/8" 4 1/8" 7 1/4" 11 3/4" MESH BACKWRAP 4 1/2" 7 1/4" BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 1 1/4" MIN. HARDIE TRIM BOARD AT JAMB BEYOND MA-1, RE: ELEVATIONS NOTES MOISTURE BARRIER, LAP OVER DRIP EDGE BELOW MASONRY VENEER ADHESIVE HARDIE LAP SIDING, RE: SPEC. WOOD FRAMING, RE: STRUCTURAL 3/4" VERTICAL WOOD FURRING STRIPS 6" TYP. 1 1/2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 3/8" SLOPED PREFINISHED METAL DRIP EDGE SET IN SEALANT. PROVIDE 4" END DAMS W/ CONTINUOUS SEALANT HARDIE TRIM BOARD, SEAL PERIMETER 1 1/2" 103' - 4" FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND OVER FLASHING BELOW 20 GA, 3" X 3" GALVANIZED ANGLE 1 1/4"D SILL CUT FROM SOLID MA-1 UNIT, RE: ELEVATIONS NOTES SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE 1:12 CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF T.O. PARAPET 125' - 0" SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS INTERIOR SHEATHING BY TENANT HIGH TEMP FLEXIBLE FLASHING MOISTURE BARRIER BEHIND BRAKE METAL. CONTINUE INTO WINDOW HEAD AND BEHIND FLASHING ABOVE SEALANT, TYP. BOTH SIDES FULLY ADHERED ROOF MEMBRANE ON 3/4" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET MASONRY VENEER ADHESIVE WOOD BLOCKING MA-1, RE: ELEVATIONS NOTES SEALANT, TYP. ALL SIDES FLUID APPLIED MOISTURE BARRIER, EXTEND BEHIND DRIP EDGE ABOVE MA-1, RE: ELEVATIONS NOTES MASONRY VENEER ADHESIVE 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 4 1/8" 7 1/4" BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS PARAPET BRACE, RE: STRUCTURAL 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 READY ACCESS 275 SERVICE WINDOW AND AIR CURTAIN, MATCH STOREFRONT FRAMING 11 3/8" 4 ENLARGED SECTION DETAIL - SIDING/BRICK TRANSITION GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 SCALE: 3" = 1'-0" MESH BACKWRAP AND DRAINEDGE 11 3/8" TOP OF PARAPET BEYOND 7 1/4" CHORD DESIGN STUDIO, P.C. MEP FULLY ADHERED ROOF MEMBRANE, WRAP OVER TOP OF PARAPET PLYWOOD SHEATHING, RE: STRUCTURAL ARCHITECT 108' - 0" 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP OVER THE TOP OF THE PARAPET PROVIDE 1/4" CLEAR WEEP TUBES @ 12" O.C. IN GROUT JOINT PREFINISHED BRAKE METAL INFILL FOR WIDTH OF AIR CURTAIN. ALIGN FACE OF BRAKE METAL W/ FACE OF BRICK. FINISH TO MATCH CANOPY WOOD FRAMING, RE: STRUCTURAL CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET WOOD HEADER, RE: STRUCTURAL 108' - 2 3/4" 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 3/4" EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 SLOPED PREFINISHED METAL DRIP EDGE SET IN SEALANT, LAP BEHIND MOISTURE BARRIER. PROVIDE 4" END DAMS W/ CONTINUOUS SEALANT INTERIOR SHEATHING BY TENANT OWNER 11 3/8" 4 1/8" 4 1/8" 7 1/4" 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL 2 ENLARGED SECTION DETAIL - WINDOW HEAD INTERIOR SHEATHING BY TENANT SCALE: 3" = 1'-0" MA-1, RE: ELEVATIONS NOTES COVER BOARD, OVER RIGID INSULATION, OVER PLYWOOD DECK. FULLY ADHERED ROOF MEMBRANE OVER COVER BOARD, OVER RIGID INSULATION, OVER PLYWOOD DECK. WRAP ROOFING MEMBRANE BEHIND FLASHING ABOVE FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND OVER DRAINEDGE BELOW STAINLESS STEEL SHELF 1' - 1" SEALANT, TYP. BOTH SIDES 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 FLEXIBLE FLASHING OVER MOISTURE BARRIER 103' - 0" WOOD FRAMING, RE: STRUCTURAL WEEP SCREED 2" VENTILATED DRAINEDGE READY ACCESS 275 SERVICE WINDOW AND AIR CURTAIN, MATCH STOREFRONT FRAMING 1 3/4" WEEP SCREED 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS STAINLESS STEEL BENT PLATE, EXTEND UNDER SILL AND OVERLAP STAINLESS STEEL SHELF. SET IN CONTINUOUS BED OF SEALANT 20 GA, 3" X 3" GALVANIZED ANGLE MESH BACKWRAP AND DRAINEDGE VENTILATED DRAINEDGE 6" 120' - 10 3/4" +/- 2 5/8" (2" MIN. @ PAVING / 4" MIN. @ GRADE) MASONRY VENEER ADHESIVE T.O. BRICK 102' - 8" 1 1/4"D SILL CUT FROM SOLID MA-1 UNIT, RE: ELEVATIONS NOTES 3/4" 6 1/2" WOOD FRAMING, RE: STRUCTURAL LEVEL 01 100' - 0" BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS CONCRETE SLAB ON GRADE ON WATER BARRIER, ON COMPACTED FILL PER THE GEOTECHNICAL REPORT, RE: STRUCTURAL WOOD FRAMING, RE: STRUCTURAL 8" 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL FLUID APPLIED MOISTURE BARRIER, EXTEND BEHIND ANGLE AND FLEXIBLE FLASHING ABOVE INTERIOR SHEATHING BY TENANT COMPRESSIBLE FILLER AND SEALANT, RE: CITY STANDARD DRAWING ON CIVIL DETAIL SHEET MESH BACKWRAP MASONRY VENEER ADHESIVE TRUSS / PARAPET BRACE, RE: STRUCTURAL STARBUCKS CORE & SHELL RE: STRUCTURAL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 MA-1, RE: ELEVATIONS NOTES BOARD INSULATION, RE: CODE STUDY SHEET FOR RVALUE REQUIREMENTS 2/17/2020 10:26:25 AM WOOD TRUSS, RE: STRUCTURAL 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 4 1/8" 7 1/4" 11 3/8" 5 ENLARGED SECTION DETAIL - ROOF / BRICK TRANSITION SCALE: 1 1/2" = 1'-0" 3 ENLARGED SECTION DETAIL - CURB SCALE: 3" = 1'-0" 1 ENLARGED SECTION DETAIL - WINDOW SILL SCALE: 3" = 1'-0" Project Number: SECTION DETAILS A603 19022 8 1/2" 1' - 6 7/8" STEEL TUBE, RE: STRUCTURAL WOOD FRAMING, RE: STRUCTURAL 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL INTERIOR SHEATHING BY TENANT BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS SEALANT, TYP. BOTH SIDES 7 1/4" DASH INDICATES BASEPLATE BELOW STEEL COLUMN, RE: STRUCTURAL WOOD BLOCKING 11 3/4" ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES WOOD FRAMING, RE: STRUCTURAL 8 1/2" 2" SEALANT, TYP. BOTH SIDES 11 3/8" FLEXIBLE FLASHING, LAP OVER MOISTURE BARRIER ARCHITECT 4 1/8" HARDIE LAP SIDING, RE: SPEC. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 2" 1 1/2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS CHORD DESIGN STUDIO, P.C. 2 1/8" 4 1/8" 11 3/8" 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 7 1/4" 2 1/2" 4 1/2" OWNER ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES t: 303.694.2445 MOISTURE BARRIER, WRAP INTO JAMB BEHIND FLEXIBLE FLASHING CIVIL MA-1, RE: ELEVATIONS NOTES 3/4" WOOD VERTICAL FURRING STRIPS FLEXIBLE FLASHING, LAP OVER MOISTURE BARRIER MASONRY ADHESIVE FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND FLEXIBLE FLASHING AT JAMB MESH BACKWRAP MA-1 CORNER UNITS, RE: ELEVATION NOTES 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 2' - 0" RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL 3 PLAN DETAIL - MATERIAL TRANSITION CORNER PORTIS STRUCTURAL DESIGN SCALE: 3" = 1'-0" 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP 11 3/8" 7 1/4" 2" GIVEN & ASSOCIATES 2 1/8" ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 11 3/4" 2 1/2" 2" 7 1/4" SEALANT, TYP. BOTH SIDES MA-1 CORNER UNITS, RE: ELEVATION NOTES WOOD FRAMING, RE: STRUCTURAL ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES FLEXIBLE FLASHING, LAP OVER MOISTURE BARRIER FLUID APPLIED MOISTURE BARRIER, CONTINUE BEHIND MESH BACKWRAP AND FLEXIBLE FLASHING SEALANT, TYP. BOTH SIDES LINE OF BRICK SILL BELOW 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER 2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS FLEXIBLE FLASHING, LAP OVER MOISTURE BARRIER 1' - 0 5/8" DASH INDICATES BASEPLATE BELOW DATE 27 DEC 2019 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL INTERIOR SHEATHING BY TENANT WOOD FRAMING, RE: STRUCTURAL DESCRIPTION PERMIT SET 2' - 8" BATT INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 HARDIE LAP SIDING, RE: SPEC. INTERIOR SHEATHING BY TENANT COPYRIGHT: 2019 WOOD BLOCKING MESH BACKWRAP 8 1/2" 3/4" WOOD VERTICAL FURRING STRIPS 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL WOOD BLOCKING WOOD FRAMING, RE: STRUCTURAL STEEL TUBE, RE: STRUCTURAL SEALANT, TYP. BOTH SIDES MASONRY ADHESIVE SEALANT, TYP. BOTH SIDES ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES ALUMINUM STOREFRONT SYSTEM, RE: ELEVATION NOTES MA-1, RE: ELEVATIONS NOTES 4 5/8" 7 1/4" 7 1/4" 1 1/2" BOARD INSULATION, RE: CODE STUDY SHEET FOR R-VALUE REQUIREMENTS 1 3/4" MOISTURE BARRIER, WRAP BEHIND FLEXIBLE FLASHING AT JAMB DASH INDICATES BASEPLATE BELOW FLEXIBLE FLASHING OVER MOISTURE BARRIER 2/17/2020 10:26:25 AM 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER MOISTURE BARRIER, WRAP INTO JAMB, TYP. BLOCKING AS REQUIRED 2 PLAN DETAIL - WINDOW JAMB AT SIDING SCALE: 3" = 1'-0" 2" MA-1 CORNER UNITS, RE: ELEVATION NOTES 2 1/8" 2 1/2" 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER 4 1/2" 2" BLOCKING AS REQUIRED STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: FLEXIBLE FLASHING, LAP OVER MOISTURE BARRIER STEEL TUBE, RE: STRUCTURAL 3" X 3" PREFINISHED METAL DOWNSPOUT, RE: CIVIL FOR CONTINUATION AND PLUMBING FOR FLOW CALCULATIONS, TYP OF 3 MA-1 CORNER UNITS, RE: ELEVATION NOTES PLAN DETAILS 2' - 0" 1 PLAN DETAIL - WINDOW JAMB AT BRICK SCALE: 3" = 1'-0" A604 19022 3' - 6" MIN. 8 9 A605 A605 STEEL PLATFORM 121' - 8" PRE-FINISHED METAL COPING, RE: SECTION DETAILS FOR TYP COPING DETAIL 3" MIN. ABOVE ROOFING STEEL PLATFORM PRE-FINISHED METAL COPING 7" MIN. TYP 1' - 0" LOCKED SECURITY PANEL FOR ROOF LADDER ACCESS 7" MIN. 7" MIN. OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 1'-6" MIN. CLEAR ARCHITECT EXTERIOR WALL ASSEMBLY CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 EXTERIOR WALL ASSEMBLY, RE: SECTION DETAILS STEEL WALL BRACKET BY LADDER MFR t: 303.694.2445 PLAN AT ROOF LADDER LOCKED HINGED SECURITY PANEL FOR ROOF ACCESS LADDER 9 SCALE: 3/4" = 1'-0" +/- 25' - 9" 10 SECTION DETAIL AT ROOF LADDER SCALE: 3/4" = 1'-0" PORTIS STRUCTURAL DESIGN GASKET 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 MEP GALV. SCREWS AT 8" O.C. MAX IN 5/4" x 4" FIRE TREATED WOOD NAILER GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 GASKETED FASTENER AT 12" O.C. MAX NOTES: 1. PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC. 2. PIPE MUST BE FULLY ANCHORED 3. FOLLOW ALL ROOFING MFR. INSTRUCTIONS AND RECOMMENDATIONS 14" MIN. 14 GA GALV. SHEET METAL COUNTERFLASHING w/ DRIP EDGE, 4" FACE TPO MEMBRANE ADHERED w/ BONDING ADHESIVE PER MFR. 4' - 0" RIDGETOP ENGINEERING STRUCTURAL CONTINUOUS BEAD OF SEALANT PER ROOFING MFR. 3/4" MIN DIAMETER RUNGS CAPABLE OF WITHSTANDING 300 LB LOAD CIVIL 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 RTU CURB OR MOUNTED EXHAUST FAN LOCKED HINGED SECURITY PANEL FOR ROOF ACCESS LADDER EXTERIOR WALL ASSEMBLY, RE: SECTION DETAILS 2X BLOCKING AT EACH LADDER WALL BRACKET, RE: LADDER MANUFACTURER'S REQUIREMENTS PRE-FABRICATED GALV. CURB RIGID INSULATION CONT. BEAD OF SEALANT OVER SCREWS AT 12" O.C. AND AT EDGE OF CURB FLANGE CONT. SEALANT PER TPO MFR. TYPICAL LAP SPLICE 2" S. STL. CLAMPING RING FIELD FABRICATED METAL HOOD PRE-MOLDED TPO PIPE FLASHING TREATED WOOD NAILERS EQUAL HEIGHT OF ROOF INSULATION AND COVER BOARD TYPICAL LAP SPLICE 2" FILL GAP w/ FOAM SEALANT COPYRIGHT: 2019 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 WOOD FRAMING, RE: STRUCT. DESCRIPTION PERMIT SET DATE 27 DEC 2019 NOTES: 1. INSTALL COUNTER-FLASHING AND RECEIVER BEFORE SETTING UNIT 2. NO PENETRATION OF CURB SIDEWALL ALLOWED 7 8 ROOF LADDER ELEVATION SCALE: 1/2" = 1'-0" 6 TYPICAL ROOF CURB 5 SCALE: 3" = 1'-0" TYPICAL ROOF PENETRATION SCALE: 3" = 1'-0" ROOF LADDER SECTION SCALE: 1/2" = 1'-0" WALL ASSEMBLY PER PLAN TPO MEMBRANE OVER BONDING ADHESIVE OVER SUBSTRATE. CONTINUE MEMBRANE UP AND OVER PARAPET STARBUCKS CORE & SHELL 6" 1 1/2" DIA. COMPRESSIBLE TUBE COMPRESSIBLE INSULATION w/ RETAINER FASTENER AND 2" SEAM PLATE AT 12" O.C. TYPICAL LAPPED SPLICE PIPE 2" 2" MIN MIN 4X4 WOOD PIPE / EQUIP. SUPPORT, RE: PLUMB. 2" TPO PROTECTION LAYER SLOPE FULLY ADHERED TPO ROOF MEMBRANE MECHANICAL ANCHOR LAPPED ROOFING MEMBRANE 1/2" HIGH DENSITY POLYISO COVERBOARD 2" CONTINUOUS WELD FULLY ADHERED RIGID INSULATION (R-30) VARIES 2/17/2020 10:26:27 AM SLOPE 4 TYPICAL ROOF EXPANSION SCALE: 3" = 1'-0" 3 TYPICAL EQUIPMENT SUPPORT SCALE: 3" = 1'-0" 2 TYPICAL LAP SPLICE SCALE: 3" = 1'-0" 1 TYPICAL TPO ROOF SYSTEM SCALE: 3" = 1'-0" 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 Project Number: ROOF DETAILS A605 19022 OWNER EVC-WDG TOWER II, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF CONTINUOUS SOLID BLOCKING, SLOPE TOWARD ROOF SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE SLOPED 20 GA PREFINISHED METAL COPING W/ DRIP EDGE SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS CONTINUOUS CLEAT: NO EXPOSED FASTENERS ON OUTSIDE FACE OF PARAPET SECURE ROOF SIDE OF COPING W/ EXPOSED GASKETED FASTENERS CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN SEALANT, TYP. BOTH SIDES HARDIE TRIM BOARD, SEAL PERIMETER SEALANT, TYP. BOTH SIDES HARDIE TRIM BOARD, SEAL PERIMETER FULLY ADHERED ROOF MEMBRANE ON 5/8" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET FULLY ADHERED ROOF MEMBRANE ON 5/8" PLYWOOD SHEATHING, CONTINUE OVER TOP OF PARAPET LAP MOISTURE BARRIER OVER TOP OF PARAPET AND SCUPPER FLANGE BELOW LAP MOISTURE BARRIER OVER TOP OF PARAPET AND SCUPPER FLANGE BELOW 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL 3/4" PLYWOOD SHEATHING, RE: STRUCTURAL WOOD FRAMING, RE: STRUCTURAL WOOD FRAMING, RE: STRUCTURAL MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 HARDIE BOARD WALL ASSEMBLY, RE: SECTION DETAILS HARDIE BOARD WALL ASSEMBLY, RE: SECTION DETAILS 11 3/4" 11 3/4" 4 1/2" 1001 BANNOCK STREET, SUITE 441 DENVER, CO 80204 t: 720.501.4900 7 1/4" 4 1/2" 7 1/4" COPYRIGHT: 2019 SEAM EDGE, TYP. ALL SIDES SLOPED PREFINISHED METAL DRIP EDGE, LAP BEHIND MOISTURE BARRIER 4" H X 6" W REINFORCED MEMBRANE FLASHING, TYP. ALL SIDES PREFINISHED SHEET METAL SCUPPER W/ DRIP EDGE, MATCH COPING. SCUPPER REFER TO APPLICABLE SMACNA (LATEST EDITION) DETAILS RE: ROOF PLAN FOR SIZE SEAM EDGE, TYP. ALL SIDES 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER EXTEND PREFINISHED FLASHING TO THE INSIDE OF THE PARAPET SLOPED PREFINISHED METAL DRIP EDGE, LAP BEHIND MOISTURE BARRIER REINFORCED MEMBRANE FLASHING, TYP. ALL SIDES 4" H X 6" W EXTEND PREFINISHED FLASHING TO THE INSIDE OF THE PARAPET TPO FLASHING WITH TPO PRIMER PREFINISHED SHEET METAL SCUPPER W/ DRIP EDGE, MATCH COPING. SCUPPER REFER TO APPLICABLE SMACNA (LATEST EDITION) DETAILS RE: ROOF PLAN FOR SIZE SHEET METAL CONDUCTOR HEAD, REFER TO APPLICABLE SMACNA (LATEST EDITION) DETAILS 8" H X 8" W X 6"D 1 1/2" HARDIE TRIM BOARD, SEAL PERIMETER THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 TPO FLASHING WITH TPO PRIMER STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 4" 2/17/2020 10:26:27 AM Project Number: ROOF DETAILS 2 SECTION DETAIL AT SCUPPER - OVERFLOW SCALE: 3" = 1'-0" 1 SECTION DETAIL AT SCUPPER SCALE: 3" = 1'-0" A606 19022 1 1 1 1 1 1 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 ” t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 MECHANICAL SPECS, LEGEND & SCHEDULES M001 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 FIRST AND ROOF FLOOR PLANS MECHANICAL M101 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 8/16/2019 3:41:51 PM Project Number: GIVEN MECHANICAL COM CHECK & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 19022 M600 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING ” ” ” … “ “ ” “ ” 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 ” “ STRUCTURAL ” PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 ” MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 PLUMBING SPECS SCHEDULES & LEGEND P001 02-07-2020 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 2 DESCRIPTION PERMIT SET DATE 07 FEB 2020 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC FIRST FLOOR PLUMBING PLANS MECHANICAL & ELECTRICAL ENGINEERS 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 P101 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN ROOF PLUMBING PLAN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 P102 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN PLUMBING ISOMETRICS & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 P400 02-07-2020 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 2 DESCRIPTION PERMIT SET DATE 07 FEB 2020 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN PLUMBING DETAILS & ASSOCIATES INC MECHANICAL & ELECTRICAL ENGINEERS 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 P500 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 ELECTRICAL SPECS LEGEND ONE-LINE E001 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN ELECTRICAL SITE PLAN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 E002 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 FIRST FLOOR ELECTRICAL PLANS E101 12/27/2019 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 DESCRIPTION PERMIT SET DATE 27 DEC 2019 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 ELECTRICAL PANEL SCHEDULES E600 02/14/2020 OWNER EVC-WDG TOWER, LLC 3501 SW FAIRLAWN RD, SUITE 200 TOPEKA, KS 66614 t: 785.272.1398 ARCHITECT CHORD DESIGN STUDIO, P.C. 1425 MARKET STREET SUITE 220 DENVER, CO 80202 t: 303.694.2445 CIVIL RIDGETOP ENGINEERING 541 E GARDEN DR UNIT N WINDSOR, CO 80550 t: 970.663.4552 STRUCTURAL PORTIS STRUCTURAL DESIGN 1515 WYNKOOP STREET SUITE 360 DENVER, CO 80202 t: 720.501.4900 MEP GIVEN & ASSOCIATES 735 SOUTH XENON COURT LAKEWOOD, CO 80228 t: 303.716.1270 COPYRIGHT: 2018 THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF CHORD DESIGN STUDIO, P.C. # 1 2 3 DESCRIPTION PERMIT SET PERMIT SET PERMIT SET DATE 27 DEC 2019 07 FEB 2020 14 FEB 2020 STARBUCKS CORE & SHELL 18201 GREEN VALLEY RANCH BLVD DENVER, CO 80249 19022 8/16/2019 3:41:51 PM Project Number: GIVEN & ASSOCIATES INC 735 S. Xenon Ct. #201 Lakewood, Colorado 80228 Ph: 303.716.1270 Fax: 303.716.1272 www.givenandassociates.com Project # 19134 ELECTRICAL ENERGY COMPLIANCE E700