CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REVISION SHEET Rev. No. Date 0 19-04-2022 Description - REV. : 0 PAGES : 2 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 3 of 64 DAFTAR ISI DAFTAR ISI 1 PENDAHULUAN .......................................................................................................................6 1.1. LATAR BELAKANG ...............................................................................................................6 1.2. SATUAN DAN BAHASA ........................................................................................................6 1.3. SASARAN .................................................................................................................................6 1.4. ELEVASI STRUKTUR .............................................................................................................6 1.5. GAMBARAN UMUM ..............................................................................................................7 2 KRITERIA TEKNIS ..................................................................................................................9 2.1. PERATURAN DAN STANDAR ..............................................................................................9 2.2. UMUR RENCANA ...................................................................................................................9 2.3. MATERIAL ...............................................................................................................................9 2.3.1. BETON .................................................................................................................................................... 9 2.3.2. BAJA TULANGAN .............................................................................................................................. 10 2.3.3. BAJA PROFIL ...................................................................................................................................... 10 2.3.4. TIANG PANCANG BAJA ................................................................................................................... 11 2.4. KOMBINASI PEMBEBANAN .............................................................................................. 11 2.4.1. KONDISI OPERASIONAL .................................................................................................................. 13 2.4.2. KONDISI GEMPA ................................................................................................................................ 15 3 CATWALK ............................................................................................................................... 17 3.1. PEMBEBANAN ......................................................................................................................17 3.1.1. BEBAN MATI ...................................................................................................................................... 17 3.1.2. BEBAN HIDUP .................................................................................................................................... 17 3.1.3. BEBAN LINGKUNGAN ...................................................................................................................... 17 3.1.4. BEBAN GEMPA................................................................................................................................... 23 3.2. ANALISIS STRUKTUR ......................................................................................................... 27 3.2.1. PEMODELAN STRUKTUR................................................................................................................. 27 3.2.2. FIXITY POINT ..................................................................................................................................... 27 3.2.3. PROPERTI PENAMPANG ELEMEN STRUKTUR ........................................................................... 29 3.2.4. PLOT PEMODELAN STRUKTUR CAT WALK ................................................................................ 29 3.2.5. HASIL ANALISA STRUKTUR ........................................................................................................... 35 3.3. ANALISA GEOTEKNIK ........................................................................................................ 41 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 4 of 64 3.3.1. GAMBARAN UMUM .......................................................................................................................... 41 3.3.2. PARAMETER PERENCANAAN GEOTEKNIK ................................................................................ 41 3.3.3. ANALISIS PONDASI DALAM BERDASARKAN KORELASI NILAI N-SPT ................................ 48 3.1.1.1 TAHANAN GESER SELIMU TIANG ................................................................................................. 48 3.1.1.2 TAHANAN GESER SELIMUT PADA TANAH LEMPUNG ............................................................. 49 3.1.1.3 TAHANAN UJUNG TIANG ................................................................................................................ 51 3.3.4. ANALISA PONDASI CATWALK ...................................................................................................... 53 3.4. ANALISIS STRUKTUR ATAS .............................................................................................. 60 3.4.1. PILECAP BETON PADA CATWALK ................................................................................................ 60 3.4.2. INFILL CONCRETE PADA PONDASI CATWALK.......................................................................... 63 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 5 of 64 DAFTAR TABEL Tabel 2-1 Tabel Minimum Selimut Beton ............................................................................................................. 10 Tabel 2-2 Karakteristik Baja Tulangan.................................................................................................................. 10 Tabel 2-3 Kombinasi Pembebanan ........................................................................................................................ 11 Tabel 2-4 Formula Kombinasi Pembebanan (BS 6349 Part 2) .............................................................................. 13 Tabel 2-5 Faktor Parsial Beban () (BS 6349 Part 2) ............................................................................................ 14 Tabel 2-6 Faktor Kombinasi (ψ) (BS 6349 Part 2) ................................................................................................ 15 Tabel 3-5 Drag Koefisien (CD) untuk Pier............................................................................................................ 18 Tabel 3-6 Koefisien Situs, Fa ................................................................................................................................ 25 Tabel 3-7 Koefisien Situs, FV ............................................................................................................................... 25 Tabel 3-8 Summary Reaksi Perletakan Maksimum SPP609 t=9.53mm Catwalk ................................................. 35 Tabel 3-9 Summary Gaya Dalam Tiang Maksimum SPP609 t=9.53mm Breasting Catwalk ............................... 36 Tabel 3-10 Defleksi Struktur Catwalk ................................................................................................................... 37 Tabel 3-11 Tegangan Pada Tiang Pancang Catwalk ............................................................................................. 38 Tabel 3-12 Daya Dukung Pondasi Tiang Pancang Baja – BH-02 dengan data sondir S-8.................................... 55 Tabel 3-13 Gaya Dalam Pilecap Struktur Catwalk Tiang ..................................................................................... 60 DAFTAR GAMBAR Gambar 1-1 General Layout TBBM Tembilahan .................................................................................................... 7 Gambar 1-2 Struktur Catwalk.................................................................................................................................. 8 Gambar 3-2 Drag Koefisien (CD) untuk Struktur Atas ......................................................................................... 18 Gambar 3-3 Skala Beaufort ................................................................................................................................... 19 Gambar 3-4 PGA, MCER Kelas Situs SB ............................................................................................................. 24 Gambar 3-5 SS, MCER Kelas Situs SB ................................................................................................................ 24 Gambar 3-6 S1, MCER Kelas Situs SB................................................................................................................. 25 Gambar 3-7 Response Spektrum ........................................................................................................................... 27 Gambar 3-8 Model 3-D Struktur Catwalk ............................................................................................................ 29 Gambar 3-10 Plot Beban Mati Tambahan – Beton Pengisi Tiang......................................................................... 30 Gambar 3-12 Plot Beban Mati dari Tambahan Catwalk........................................................................................ 30 Gambar 3-12 Plot Beban Hidup dari Catwalk ....................................................................................................... 31 Gambar 3-18 Plot Beban Angin Arah X................................................................................................................ 31 Gambar 3-19 Plot Beban Angin Arah Y................................................................................................................ 32 Gambar 3-20 Plot Beban Arus Arah X .................................................................................................................. 32 Gambar 3-21 Plot Beban Arus Arah Y .................................................................................................................. 33 Gambar 3-22 Plot Beban Gelombang Arah X ....................................................................................................... 33 Gambar 3-23 Plot Beban Gelombang Arah Y ....................................................................................................... 34 Gambar 3-24 Plot Beban Gempa ........................................................................................................................... 34 Gambar 3-25 Rasio Tegangan Maksimum Tiang Akibat Bearthing Load pada Catwalk ..................................... 40 Gambar 3-27 Titik Bor BH-05 .............................................................................................................................. 42 Gambar 3-28 Daya Dukung Aksial Pondasi Tiang ............................................................................................... 48 Gambar 3-29 Faktor adhesi API metode 2 (1986) ................................................................................................. 49 Gambar 3-30 Defleksi vs Kedalaman Tiang Catwalk – SPP609 T9.53 mm – BH-05 .......................................... 58 Gambar 3-31 Beban vs penurunan Tiang Catwalk – SPP711 T9.53 mm – BH-05 ............................................... 59 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 1 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 6 of 64 PENDAHULUAN 1.1. LATAR BELAKANG PERUSAHAAN dalam hal ini PT. ELNUSA PETROFIN bermaksud melaksanakan pembangunan 1 unit dermaga yang terdiri dari: 2 (dua) unit breasting dolphin dan 2 (dua) unit mooring dolphin dermaga TBBM Tembilahan untuk disandari kapal pengangkut BBM dengan kapasitas 3500 DWT. Secara garis besar, lingkup pekerjaan yang akan dilaksanakan adalah meliputi pembangunan breasting dolphin termasuk pemasangan rubber fender, chatodic protection, bollard dan catwalk Elevasi permukaan atas Catwalk, breasting dolphin, mooring dolphin, dan struktur lainnya adalah pada + 0.497 m LWS. Pada proses perencanaannya, beban sandar maupun tambat kapal diperhitungkan bekerja pada breasting dolphin, sedangkan untuk struktur mooring dolphin hanya memperitungkan beban tambat kapal. 1.2. SATUAN DAN BAHASA Semua satuan menggunakan SI, kecuali dinyatakan lain. Bahasa yang digunakan pada laporan ini adalah Bahasa Indonesia. 1.3. SASARAN Laporan ini dimaksudkan untuk menyajikan analisis perhitungan fondasi catwalk. 1.4. ELEVASI STRUKTUR Elevasi struktur deck rencana untuk masing-masing struktur adalah sebagai berikut: (elevasi mengacu pada LWS ±0.00 m). Elevasi struktur dihitung berdasarakan perhitungan. Perhitungan elevasi catwalk berdasarkan tinggi permukaan air dan kebutuhan tinggi struktur atas bangunan, yaitu sebagai berikut: HWS + Hs + Hstruktur = Elevasi deck rencana -0.503 + 0.5 +0.5 = +0.497 m CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 7 of 64 1.5. GAMBARAN UMUM Struktur fondasi catwalk direncanakan sebagai struktur beton bertulang yang berupa blok beton serta ditumpu oleh tiang pancang pia baja, sedangkan catwalk direncanakan dengan system rangka menggunakan pipa. Dimensi struktur pilecap catwalk adalah sebagai berikut: Pilecap catwalk Panjang : 2.8 m Lebar : 0.7 m Elevasi : + 0.497 m from (LWS) Gambar layout dan gambaran struktur catwalk dapat dilihat pada gambar di bawah ini. Gambar 1-1 General Layout TBBM Tembilahan CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 1-2 Struktur Catwalk REV. : 0 PAGES : 8 of 64 CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 2 REV. : 0 PAGES : 9 of 64 KRITERIA TEKNIS Kriteria desain perencanaan struktur Jetty TBBM Tembilahan dengan uraian sebagai berikut. 2.1. PERATURAN DAN STANDAR Peraturan dan standar yang dijadikan acuan dalam pekerjaan perencanaan jetty adalah sebagai berikut. BS 5950 Structural use of Steelwork in Building BS 6349 Code of Practice for Maritime Structures OCDI. 2009. Technical Standards for Port and Harbor Facilities in Japan. Japan: The Overseas Coastal Area Development Institute of Japan. PIANC. 2002. Guidelines for the Design of Fender Systems. OCIMF. 2008. Mooring Equipment Guidelines 3rd Edition. United Kingdom: Witherby Seamanship International SNI 1726:2019 Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung SNI 2847:2019 Persyaratan Beton Struktural untuk Bangunan Gedung (Code of practice for concrete structure) American Codes and Standards: ACI, AISC, API, ASCE, AWS, ASTM Serta peraturan dan standar lain yang ekivalen. 2.2. UMUR RENCANA Perencanaan struktur dermaga dilakukan dengan memperhitungkan umur rencana struktur 30 tahun. Sedangkan elemen lainnya dilakukan pemeliharaan secara berkala dan diganti bila terjadi kerusakan yang berarti. 2.3. MATERIAL Material yang digunakan dalam perencanaan ditetapkan sebagai berikut. 2.3.1. BETON Karakteristik material beton untuk dermaga ini adalah k-350 atau setara dengan f’c 35 MPa. Selimut beton pada pekerjaan ini ditetapkan sebagai berikut. CALCULATION DOCUMENT NO. REV. : 0 PAGES : 10 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 Tabel 2-1 Tabel Minimum Selimut Beton Nominal Cover (mm) 100 100 100 75 75 80 50 60 60 40 Element Struktur Pile Cap/ Concrete Block Top Side Bottom Top Balok Side Bottom Slab Top Side Bottom Infill Concrete Side Design Crack Width (mm) 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 Selimut beton ini penting untuk dipenuhi mengingat kebutuhan penulangan sangat dipengaruhi oleh jarak antara titik pusat tulangan utama terhadap sisi depan. Selimut ini juga diperhitungkan sebagai perlindungan terhadap korosi akibat air laut. 2.3.2. BAJA TULANGAN Baja tulangan pada pekerjaan ini memiliki karakteristik sebagai berikut. Tabel 2-2 Karakteristik Baja Tulangan Tulangan diameter < 13 (polos) Tulangan diameter 13 (deformed) 2.3.3. fy = Es = fy = Es = 2,400 kg/cm2 2,100,000 kg/cm2 3,900 kg/cm2 2,100,000 kg/cm2 BAJA PROFIL Untuk baja profil, plat baja dan material baja struktural lainnya mengacu kepada JIS G3101 atau ASTM A36 dengan tegangan leleh minimum 240 MPa dan modulus elastisitas 210,000 MPa. Untuk bolt dan nut direncanakan memenuhi ASTM A.307 dan ASTM A.325 seluruhnya digalvanis. CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 2.3.4. REV. : 0 PAGES : 11 of 64 TIANG PANCANG BAJA Untuk tiang pancang baja profil ASTM A252 grade 2 dengan tegangan leleh minimum baja 240 MPa dan modulus elastisitas baja 210,000 MPa 2.4. KOMBINASI PEMBEBANAN Kombinasi pembebanan harus di desain untuk memastikan penerapan kondisi beban paling extreme, dan menentukan tingkat stress maksimum dari masing-masing elemen struktur. Struktur atas harus di desain untuk menahan semua kombinasi beban yang diasumsikan bekerja secara bersamaan pada struktur. Beban dapat berkerja secara langsung pada struktur atas atau secara tidak langsung melalui tiang pancang. Kombinasi pembebanan dibagi menjadi dua yaitu kondisi operasional dan kondisi gempa. Kombinasi pembebanan untuk kondisi operasional mengacu pada British Standard BS6349-2: 2010 sedangkan untuk kondisi gempa akan mengacu pada SNI 1726-2019. Kombinasi pembebanan yang digunakan pada analisis pemodelan sebagai berikut. Tabel 2-3 Kombinasi Pembebanan Keterangan : DL : Dead Load SDL : Superimposed Dead Load CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 LL : Live Load BL : Bearthing Load M : Mooring Load T : Temperature WV : Wave Load WI : Wind Load C : Current Load EQ : Earthquake Load REV. : 0 PAGES : 12 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 2.4.1. STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 13 of 64 KONDISI OPERASIONAL Kombinasi pembebanan untuk kondisi operasional dapat dilihat pada tabel-tabel berikut ini. Tabel 2-4 Formula Kombinasi Pembebanan (BS 6349 Part 2) CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Tabel 2-5 Faktor Parsial Beban () (BS 6349 Part 2) REV. : 0 PAGES : 14 of 64 CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 15 of 64 Tabel 2-6 Faktor Kombinasi (ψ) (BS 6349 Part 2) 2.4.2. KONDISI GEMPA Kombinasi pembebanan dasar untuk untuk kondisi gempa berdasarkan SNI 1729-2019 dapat dilihat sebagai berikut ini. Kondisi Ultimit (1.2 + 0.2SDS) D + ρEQ + L (0.9 + 0.2SDS) D + ρEQ + 1.6H Kondisi Servis (1.0 + 0.14SDS) D + H + F +0.7 ρEQ (1.0 + 0.10SDS) D + H + F + 0.525ρEQ + 0.75L + 0.75(Lr atau R) (0.6 + 0.14SDS) D + H + 0.7 ρEQ CALCULATION DOCUMENT NO. REV. : 0 PAGES : 16 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 Keterangan : D = Beban mati L = Beban hidup H = Beban tekanan tanah F = Beban banjir EQ = Beban gempa PENGECUALIAN Faktor beban untuk L pada kombinasi boleh diambil sama dengan 0,5 kecuali untuk ruangan garasi, ruangan pertemuan dan semua ruangan yang nilai beban hidupnya lebih besar daripada 500 kg/m. Berdasarkan formula di atas, kombinasi pembebanan yang akan digunakan untuk analisis struktur kondisi gempa adalah sebagai berikut. LOAD COMBINATION FACTORS SEISM IC LOAD CONDIT ION D L SD L LL BL M T W V WI C EQ 1 X X - - - - - - - X 2 X X X - - - - - - X Keterangan : DL = Beban mati WV = Beban gelombang SDL = Beban mati tambahan WI = Beban angin LL = Beban hidup EQX = Beban gempa arah x BL = Beban sandar kapal EQY = Beban gempa arah y M = Beban tarik kapal EQV = Beban gempa vertikal T = Beban tempratur CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 3 REV. : 0 PAGES : 17 of 64 CATWALK 3.1. PEMBEBANAN 3.1.1. BEBAN MATI Berat sendiri material yang diperhitungkan dalam perencanaan struktur adalah sebagai berikut: Beton : 2.400 t/m3 Beton Bertulang : 2.500 t/m3 Beton Prategang : 2.450 t/m3 Baja : 7.850 t/m3 Beban mati tambahan/superimposed dead load merupakan berat struktur yang diperhitungkan sebagai beban mati tambahan, seperti bollard, fender, dan beton pengisi tiang. Untuk beban mati tambahan yang di aplikasikan adalah sebagai berikut : Beton pengisi tiang SPP 609.6 t = 9.53 mm = 0.274 m2 * 1.5m * 24 kn/m3= 9.854 kN Beban catwalk : Beban catwalk diambil dari support reaction perhitungan catwalk 3.1.2. BEBAN HIDUP 3.1.2.1. Beban Hidup Merata Beban hidup yang akan digunakan dalam perhitungan adalah sebagai berikut : LL diambil dari support reaction perhitungan catwalk 3.1.3. BEBAN LINGKUNGAN 3.1.3.1. Beban Angin Beban angin yang bekerja pada permukaan dari struktur atas, dengan proyeksi area ‘A’, dihitung berdasarkan British Standard. Fv q A CD q 0.613 Vc2 Fv= beban angin (kN) A = solid area (m²) q = dynamic preasure head (N/mm2) CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Cd = koefisien drag Vc = kecepatan angin rencana Gambar 3-1 Drag Koefisien (CD) untuk Struktur Atas Tabel 3-1 Drag Koefisien (CD) untuk Pier REV. : 0 PAGES : 18 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 19 of 64 Kecepatan angin rencana yang diperhitungkan dalam perencanaan beban angin adalah sebagai berikut: Kecepatan angin yang digunakan dalam perencanaan sebesar 33.333 m/s ≈ 120 km/jam. Kecepatan angin tersebut ditentukan berdasarkan pada pengalaman konsultan, yang mana nilai tersebut masih diatas nilai kecepatan yang ditentukan oleh UBC 1997 yaitu sebesar 120 km/jam, selain itu kecepatan angin tersebut merupakan nilai batasan dari kecepatan angin badai. Pada kecepatan angin kondisi ekstrim, kapal tidak diijinkan beroperasi di areal dermaga (sandar atau tambat). beroperasi di areal dermaga (sandar atau tambat). 33,333 m/s Gambar 3-2 Skala Beaufort CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 20 of 64 Beban angin diaplikasikan pada sepanjang struktur atas catwalk pada arah memanjang serta pada tiang pancang dalam kondisi ekstrim. Perhitungan beban angin dapat dilihat sebagai berikut. Perhitungan Beban Angin Pada Pilecap Kecepatan angin pada kondisi ekstrem 120 km/jam (33 m/s). Pada Dek 120 Kecepatan angin Vw = km/h 33.333 m/s = Dynamic pressure head q = 0.613 * V w = 681.111 N/m2 0.50 Tebal Dek d = m 3.00 Lebar Struktur b = m 6.00 b/d = Drag coeficient is obtain from graphic 1.50 CD = Beban angin per meter 510.833 N/m qv = q * d * CD = 0.052 = ton/m Beban angin yang digunakan ialah beban angin ketika kondisi ekstrem sebesar 0.052 ton/m CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 21 of 64 Perhitungan Beban Angin Pada Tiang SPP 609 Kecepatan angin pada kondisi ekstrem 120 km/jam (33 m/s). 120 Kecepatan angin Vw = km/jam 33.333 = m/s Dynamic pressure head 2 q = 0.613 * V w = 681.1 N/m Panjang tiang dari bawah dek hingga Lower Water Surface 3.4 t = m 0.609 Diameter tiang = m 1.913 Pheripery of pier b 0 = π * D = mm 1.0 m 0.5 * b 0 = 3.6 t/b = Drag koefisien diperoleh dari tabel 0.5 CD = Beban angin per meter 325.781 N/m q v = q * 0.5*b 0 * C D = 0.033 = ton/m Beban angin yang digunakan ialah beban angin ketika kondisi ekstrem sebesar 0.033 ton/m 3.1.3.2. Beban Arus Arus yang dipengaruhi oleh drag load pada tiang pancang diperhitungkan berdasarkan pada Bristish Standard. FD 1 CD V 2 An 2 Dimana: FD = total drag force per satuan panjang CD = koefisien drag ρ = berat jenis air laut V = kecepatan arus rencana An = proyeksi area per satuan panjang Beban arus dianggap memperhitungkan marine growth setebal 150mm. Beban arus di perhitungkan sebagai berikut: Untuk keperluan perencanaan, beban arus diperhitungkan sebesar 2 knot ≈ 1.03 m/s. CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 22 of 64 Perhitungan beban arus pada tiang pancang dapat dilihat sebagai berikut : Beban Arus Density of fluid ρ = 1025 3 ton/m Drag coeficient for current refer to Clause 38.2 of BS6349 : Part 1 : 2000 1 CD = 0.609 Diameter of pile = m 0.609 m with 150 mm marine growth. For diameter 0.609 Diameter pile (D) = m 0.15 Marine growth = m 0.909 m Diameter of pile due to marine growth D' = 0.609 + 0.15 = 2.856 mm Pheripery of pier b0 = π * D = 1.500 Current velocity Vc = knot 0.773 = m/s Steady drag pressure 2 2 P = 0.5 * C D * ρ * V c = 305.838 N/mm Steady drag force per meter 0.437 F D' = P * π * D/2 = kN/m height 0.045 = ton/m 0.045 ton/m Current load which is used for modeling is current load on extreme condition is = 3.1.3.3. Beban Gelombang Beban gelombang pada struktur yang diperhitungkan hanyalah beban terhadap tiang pancang. Beban gelombang pada struktur deck tidak diperhitungkan. Elevasi deck direncanakan akan cukup tinggi untuk menghindari beban angkat gelombang. Tinggi gelombang yang digunakan pada desain adalah sebagai berikut : Tinggi gelombang signifikan (Hs) : 0.5 m (asumsi) Periode : 2.9 detik (asumsi) Beban gelombang pada tiang pancang dihitung menggunakan persamaan Morison saat panjang gelombang lima kali lebih besar dari diameter pile, sesuai dengan BS 6349- 1: 2000, Clause 39.4, Wave Force. Persamaan Morison adalah sebagai berikut: F Fi Fd Ci L 5D D2 du 1 Cd Du u 4 dt 2 CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 23 of 64 dimana: F = gaya horizontal per satuan panjang pile (kN/m) Fi = gaya inersia per satuan panjang pile (kN/m) Fd = drag force per satuan panjang pile (kN/m) = berat jenis air (1.025 t/m3 untuk air laut) D = diameter pile (m) + allowance for marine growth 0.15m U(du/dt) = kecepatan horizontal partikel air pada axis pile (m/s) Ci = inersia atau koefisien massa (Ci = 2.0 untuk tube pile) Cd = koefisien drag (Cd = 1.0 untuk tube pile) L = panjang gelombang Aplikasi beban gelombang di inputkan pada program SAP. 3.1.4. BEBAN GEMPA Kondisi perencanaan terhadap gempa pada struktur ini adalah bahwa struktur akan mengalami perbaikan kecil setelah terjadi gempa. Beban gempa pada pemodelan menggunakan analisis dinamis Respons Spectra. Respon spectra gempa rencana yang digunakan adalah sesuai dengan SNI 03-1726-2019 Peraturan Gempa Indonesia, dengan periode ulang 2,500 tahun.Koefisien situs dan parameter untuk pembentukan response spektra di lokasi proyek dapat ditentukan terlebih dahulu dari peta gempa pada gambar berikut ini. Nilai yang didapatkan dari peta gempa di bawah ini adalah nilai PGA, nilai SS (parameter respons spectral percepatan gempa MCER terpetakan untuk perioda pendek, nilai S1 (parameter respons spectral percepatan gempa MCER terpetakan untuk perioda 1.0 detik. Untuk penentuan respons spectra di permukaan tanah, diperlukan suatu faktor amplifikasi seismic pada perioda 0.2 detik (Fa) dan perioda 1.0 detik (Fv). CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Lokasi Proyek Gambar 3-3 PGA, MCER Kelas Situs SB Lokasi Proyek Gambar 3-4 SS, MCER Kelas Situs SB REV. : 0 PAGES : 24 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Lokasi Proyek Gambar 3-5 S1, MCER Kelas Situs SB Tabel 3-2 Koefisien Situs, Fa Tabel 3-3 Koefisien Situs, FV REV. : 0 PAGES : 25 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 26 of 64 Dari data yang telah disebutkan pada gambar dan tabel di atas, parameter perhitungan beban gempa respon spectra adalah sebagai berikut: Lokasi struktur : Tembilahan Riau, Sumatera. Jenis tanah : Tanah Lunak (SE) PGA : 0.101 g Ss : 0.203 g S1 : 0.172 g Fa : 2.5 Fv : 3.283 Faktor keutamaan, I : 1.25 (Kategori Resiko III) Periode alami struktur ditentukan dengan modal analisis yang dihitung dengan bantuan program SAP2000. Untuk mengantisipasi terjadi gempa dalam dua arah maka pada analisa struktur terhadap beban gempa diperhitungkan kondisi sebagai berikut. ± 100% Ex ± 30% Ey ± 30% Ex ± 100% Ey Kurva respon spectra berdasarkan SNI 03-1726-2019 untuk Tanah Lunak (SE) terlihat pada gambar di bawah ini. CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 27 of 64 Gambar 3-6 Response Spektrum 3.2. ANALISIS STRUKTUR 3.2.1. PEMODELAN STRUKTUR Analisis dan pemodelan struktur dilakukan dengan menggunakan SAP 2000. Struktur akan dimodelkan secara keseluruhan dengan kombinasi pembebanan arah vertikal maupun horizontal. Interaksi tanah dengan pile dimodelkan dengan fixity point pada kedalaman di bawah seabed. 3.2.2. FIXITY POINT Bidang kontak antara tanah dengan tiang dimodelkan sebagai titik jepit (fixity point). Perhitungan fixity point ditentukan menggunakan persamaan berikut. dimana: 1/β = virtual fixity point (cm) Kh = linear horizontal spring constant (N/cm2) = 0.15 N D = diameter tiang (cm) E = modulus elastisitas pipa baja (kg/cm2) CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 I REV. : 0 PAGES : 28 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER = modulus inersia penampang (cm4) Perhitungan fixity point ditunjukkan pada perhitungan berikut. SPP D = 609 mm and thk. 9.53 mm Calculation of Fixity Point Soil Investigation Result Deck elevation N-SPT = 2.00 kh = 0.30 Section Properties Diameter of Pile OD = 60.90 ID = 58.99 Thickness t = 0.953 3 kg/cm Pile cm cm Sea Bed cm Area of Section A = 179.48 Virtual Fixity Level 2 cm Modulus Inertia I = 80642.6689 4 cm Elasticity Modulus (E) Es = 33234.0 MPa = 332340.2 kg/cm 2 Safety Factor (SF) SF = 1.00 Virtual Fixity (Zf) Zf = 277 Scouring Depth 1xD Total = Zf+SD cm 60.9 cm 337.67 cm Use Zf seabad 338.00 cm 840 cm CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 3.2.3. STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 29 of 64 PROPERTI PENAMPANG ELEMEN STRUKTUR Properti penampang pada pemodelan struktur adalah sebagai berikut. Pondasi tiang pancang: SPP Ø609 mm t=9.53 mm Outer diameter, OD = 609 mm Inner diameter, ID = 589.9 mm Thickness, t = 9.53 mm Yield strength, fy = 240 MPa Modulus of elasticity, Es = 210,000 MPa Struktur atas: Blok Beton Tebal, t = 500 mm Compressive strength, f’c = 35 MPa Modulus of elasticity, Ec 3.2.4. = 27,805.57 MPa PLOT PEMODELAN STRUKTUR CAT WALK Plot pemodelan struktur dan pembebanan pada struktur ditunjukkan pada gambar berikut. Gambar 3-7 Model 3-D Struktur Catwalk CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-8 Plot Beban Mati Tambahan – Beton Pengisi Tiang Gambar 3-9 Plot Beban Mati dari Tambahan Catwalk REV. : 0 PAGES : 30 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-10 Plot Beban Hidup dari Catwalk Gambar 3-11 Plot Beban Angin Arah X REV. : 0 PAGES : 31 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-12 Plot Beban Angin Arah Y Gambar 3-13 Plot Beban Arus Arah X REV. : 0 PAGES : 32 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-14 Plot Beban Arus Arah Y Gambar 3-15 Plot Beban Gelombang Arah X REV. : 0 PAGES : 33 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-16 Plot Beban Gelombang Arah Y Gambar 3-17 Plot Beban Gempa REV. : 0 PAGES : 34 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 3.2.5. REV. : 0 PAGES : 35 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER HASIL ANALISA STRUKTUR Hasil analisis struktur terdiri dari Reaksi perletakan Gaya dalam Defleksi struktur Stress ratio tiang pancang baja 3.2.5.1. Reaksi Perletakan Reaksi perletakan maksimum hasil analisis struktur setiap kondisi pembebanan yang direncanakan dapat dilihat pada tabel berikut. Tabel 3-4 Summary Reaksi Perletakan Maksimum SPP609 t=9.53mm Catwalk Table: Joint Reaction CaseType StepType F1 F2 Text Text Tonf Tonf Case 1 Min -3.325 -0.225 (DL+SDL+LL+T+WV+WI+C) Max -1.577 0.000 Case 2 Min -1.518 -0.225 (DL+SDL+T+WV+WI+C) Max -0.658 0.000 Case 3 Min (DL+SDL+LL+BL+T+WV+WI+C) Max Case 4 Min (DL+SDL+BL+T+WV+WI+C) Max Case 5 Min (DL+SDL+BL+T+WV+WI+C) Max Case 6 Min (DL+SDL+BL+T+WV+WI+C) Max Case 7 Min -1.720 0.000 (DL+SDL+BL+T+WV+WI+C) Max -1.684 0.000 Keterangan : DL : Dead Load SDL : Superimposed Dead Load LL : Live Load BL : Bearthing Load F3 Tonf -9.451 30.741 0.876 16.007 -2.470 21.147 M1 Tonf-m 0.000 1.036 0.000 1.036 0.000 0.000 M2 Tonf-m -31.432 -15.628 -13.595 -6.569 -16.917 -16.700 M3 Tonf-m 0.000 0.000 0.000 0.000 0.000 0.000 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 M REV. : 0 PAGES : 36 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER : Mooring Load T : Temperature WV : Wave Load WI : Wind Load C : Current Load EQ : Earthquake Load 3.2.5.2. Gaya Dalam Gaya dalam tiang maksimum hasil analisis struktur setiap kondisi pembebanan yang direncanakan dapat dilihat pada tabel di bawah ini. Tabel 3-5 Summary Gaya Dalam Tiang Maksimum SPP609 t=9.53mm Breasting Catwalk TABLE: CaseType StepType Text Text Case 1 Min (DL+SDL+LL+T+WV+WI+C) Max Case 2 Min (DL+SDL+T+WV+WI+C) Max Case 3 Min (DL+SDL+LL+BL+T+WV+WI+C) Max Case 4 Min (DL+SDL+BL+T+WV+WI+C) Max Case 5 Min (DL+SDL+LL+M+T+WV+WI+C) Max Case 6 Min (DL+SDL+M+T+WV+WI+C) Max Case 7 Min (DL+SDL+LL+EQ) Max Element Forces - Frames P V2 V3 Tonf Tonf Tonf -30.741 -3.325 -0.597 12.916 21.458 0.225 -16.007 -1.518 -0.597 2.589 8.928 0.225 -21.147 -1.720 0.000 5.781 13.110 0.000 Keterangan : DL : Dead Load SDL : Superimposed Dead Load LL : Live Load T Tonf-m 0.000 0.000 0.000 0.000 0.000 0.000 M2 Tonf-m -1.677 0.747 -1.677 0.747 0.000 0.000 M3 Tonf-m -24.341 31.432 -9.304 13.595 -14.386 16.917 CALCULATION DOCUMENT NO. REV. : 0 PAGES : 37 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 BL : Bearthing Load M : Mooring Load T : Temperature WV : Wave Load WI : Wind Load C : Current Load EQ : Earthquake Load 3.2.5.3. Defleksi Struktur Deformasi struktur akibat beban yang bekerja dirangkum pada tabel berikut. Tabel 3-6 Defleksi Struktur Catwalk TABLE: Joint Displacements Case Type U1 Text Text mm Case 1 Min 0.0000 (DL+SDL+LL+T+WV+WI+C) Max 61.2600 Case 2 Min 0.0000 (DL+SDL+T+WV+WI+C) Max 30.3200 Case 3 Min (DL+SDL+LL+BL+T+WV+WI+C) Max Case 4 Min (DL+SDL+BL+T+WV+WI+C) Max Case 5 Min (DL+SDL+LL+M+T+WV+WI+C) Max Case 6 Min (DL+SDL+M+T+WV+WI+C) Max Case 7 Min 0.0000 (DL+SDL+LL+EQ) Max 50.3000 Keterangan : DL : Dead Load SDL : Superimposed Dead Load LL : Live Load U2 mm 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 U3 mm 0.0000 8.8500 0.0000 8.5100 0.0000 0.1450 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER BL : Bearthing Load M : Mooring Load T : Temperature WV : Wave Load WI : Wind Load C : Current Load EQ : Earthquake Load REV. : 0 PAGES : 38 of 64 Berdasarkan tabel di atas defleksi maksimum untuk struktur Catwalk adalah δ = 6.1 cm < δijin ,= maka dapat disimpulkan defleksi struktur masih memenuhi syarat. 3.2.5.4. Tegangan Pada Tiang Pancang Perhitungan ratio tegangan (stress ratio) pada tiang pancang baja didasarkan pada BS 5950-1:2000 untuk case dengan hasil analisis adalah sebagai berikut: Tabel 3-7 Tegangan Pada Tiang Pancang Catwalk TABLE: Steel Design 1 - Summary Data - BS5950 2000 Allowable Case Type Type Stress Ratio Stress Ratio Text Text Unitless Unitless Case 1 (DL+SDL+LL+T+WV+WI+C) Max 0.5900 1.0000 Case 2 (DL+SDL+T+WV+WI+C) Max 0.2400 1.0000 Case 3 (DL+SDL+LL+BL+T+WV+WI+C) Max Case 4 (DL+SDL+BL+T+WV+WI+C) Max Case 5 (DL+SDL+LL+M+T+WV+WI+C) Max Case 6 (DL+SDL+M+T+WV+WI+C) Max TABLE: Steel Design 1 - Summary Data - AISC-LRFD93 Allowable Case Type Type Stress Ratio Stress Ratio Text Text Unitless mm Case 7 (DL+SDL+LL+EQ) Max 0.2250 1.0000 Keterangan : DL : Dead Load Check mm OK OK Check mm OK CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER SDL : Superimposed Dead Load LL : Live Load BL : Bearthing Load M : Mooring Load T : Temperature WV : Wave Load WI : Wind Load C : Current Load EQ : Earthquake Load REV. : 0 PAGES : 39 of 64 Tegangan maksimum pada tiang catwalk adalah sebesar 0.59 akibat beban kombinasi beban case 1, berdasarkan BS5950 2000 syarat batas tegangan maksimum akibat beban sandar kapal adalah 1 dan berikut ini merupakan ilustrasi stress ratio ketika kondisi operasional dan seismic. Gambaran rasio tegangan yang terjadi pada tiang dapat dilihat pada gambar di bawah ini CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER Gambar 3-18 Rasio Tegangan Maksimum Tiang pada Catwalk REV. : 0 PAGES : 40 of 64 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 41 of 64 3.3. ANALISA GEOTEKNIK 3.3.1. GAMBARAN UMUM Pada bab ini disajikan hasil analisa terhadap daya dukung tiang terhadap penambahan beban. Adapaun lingkup pekerjaan tersebut yaitu menganalisa daya dukung tiang, defleksi dan settlement yang terjadi pada tiang SPP 609 T9.53 mm, untuk area Catwalk. 3.3.2. PARAMETER PERENCANAAN GEOTEKNIK 3.3.2.1. Kondisi Tanah Secara umum kondisi tanah di lokasi tersebut merupakan campuran antara lapisan tanah lempung, lempung pasiran, pasir halus dan pasir padat. Dalam analisis daya dukung tiang, digunakan parameter tanah (boring log) sesuai dengan hasil investigasi tanah. Lokasi borlog yang dijadikan acuan dalam analisis daya dukung tiang area Catwalk mengacu pada titik BH-05 dan CPT-S8. CALCULATION DOCUMENT NO. REV. : 0 PAGES : 42 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 CV. JAYA CORINDO DESIGN SUMATERA UTARA TEL/ FAX : (061) 8216596 Address : Jln. Flamboyan I No. 8, Medan 20134, INDONESIA PROJECT : RENCANA PEMBANGUNAN TANGKI, JETTY DAN MOORING - TBBM PERTAMINA TEMBILAHAN DRILLING LOG Boring No. : Client : BH - 5 PT. SEIRAMA LAJU Company's Name : CV. JAYA CORINDO DESIGN - MEDAN Lay Out : Ground Elevation Boring 50.00 m Depth (m) S c Elevation a from Bench Thickness Symbol l Mark e (m) (m) (m) 0 Location TBBM PERTAMINA TEMBILAHAN KABUPATEN INDRA GIRI HILIR - RIAU 13 - 01 - 2020 Boring Log North Altitude: 0°29ʹ 54.7692ʺ Irwan Sembiring 16 - 01 - 2020 Prepared by East Altitude: 102° 56ʹ 32.6652ʺ Implement Period Chief Engineer Tarbiyatno. MT Bor Machine Engine Hammer Drop Implement Rorary Pump Tone Ground Water Level SPT Tools Free Fall Yanmar STANDARD PENETRATION TEST Depth Description (m) Depth of SPT (m) Blows Penetration each 15 cm N1 N2 N3 N Blows N2+N3 30 cm 20 30 Irwan Sembiring IN-SITU TEST N Value 10 Chief Operator - 0.00 m (From Top Soil) 40 50 Elevation of SPT Symbol (m) (m) Method of Sampling D a t e 0.00 1 2 - 3 7.10 4 Clay Color : Brownish Gray Plasticity: Medium Plastic Depth : 0,00 - 7,10 m 3.00 - 3.60 3.60 - 4.05 0 1 1 2 6.00 - 6.60 6.60 - 7.05 1 1 1 2 9.00 - 9.60 9.60 - 10.05 1 2 2 4 12.00 - 12.60 1 2 2 4 15.00 - 15.60 15.60 - 16.05 1 2 3 5 18.00 - 18.60 18.60 - 19.05 2 2 3 5 21.00 - 21.60 21.60 - 22.05 1 2 4 6 24.00 - 24.60 24.60 - 25.05 2 3 4 7 27.00 - 27.60 27.60 - 28.05 2 4 6 10 30.00 - 30.60 30.60 - 31.05 3 5 7 12 33.00 - 33.60 33.60 - 34.05 4 5 8 13 36.00 - 36.60 36.60 - 37.05 5 6 9 15 39.00 - 39.60 39.60-40.05 5 7 9 16 42.00 - 42.60 42.60 - 43.05 6 8 10 18 45.00 - 45.60 45.60 - 46.05 7 9 11 20 45.60 - 46.05 48.00 - 48.60 48.60 - 49.05 7 10 14 24 48.60 - 49.05 3.60 - 4.05 6 6.60 - 7.05 7 7.10 8 9 13 Januari 2020 5 9.60 - 10.05 10 11 12 - 11.00 13 14 12.60 - 13.05 12.60 - 13.05 Fine Sandy Clay Color : Light Gray Plasticity: Low to Medium Plastic Depth : 7,10 - 18,10 m 15 15.60 - 16.05 16 17 18 18.10 18.60 - 19.05 20 - 8.50 22 23 Sandy Clay Color : Dark Brownish Gray Plasticity : Medium Plastic Depth : 18,10 - 24,60 m 24 25 21.60 - 22.05 14 Januari 2020 19 24.60 - 25.05 24.60 26 27 27.60 - 28.05 28 29 30 30.60 - 31.05 31 33 33.60 - 34.05 34 35 36 - 37 23.90 38 39 Clay Color : Dark Gray Plasticity : High Plastic Depth : 24,60 - 50,00 m 36.60 - 37.05 15 Januari 2020 32 39.60-40.05 40 41 42 42.60 - 43.05 44 45 46 47 48 49 50 50.00 Legenda = Undisturbed Sample = Standart Penetrasion Test (SPT) = SAND = Disturbed Sample = CLAY = GRAVEL Gambar 3-19 Titik Bor BH-05 16 Januari 2020 43 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 SONDIR TEST RENCANA PEMBANGUNAN TANGKI PERTAMINA TBBM TEMBILAHAN LAY OUT : PERTAMINA TBBM TEMBILAHAN RIAU Depth (M) DATE : 11/01/2020 TESTED : MASWAN CAPACITY : 3.50 Ton CPT-8 SOIL & ROCK INVESTIGATION LOCATION REV. : 0 PAGES : 43 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INHIL - Cone Resistant Total Resistant Skin Friction Skin Friction Total Skin Friction Local Skin Friction (CR) Kg/Cm2 (TR) Kg/Cm2 (SF) Kg/Cm2 x 20/10 Kg/Cm (TSF) Kg/Cm (LSF) Kg/Cm 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.20 5.40 5.60 5.80 6.00 6.20 6.40 6.60 6.80 0 - LABORATORIUM TEKNIK SIPIL CV. JAYA CORINDO DESIGN MEDAN 0 - 0 Checked by 0 TARBIYATNO, MT 0 - 0.0 Page : CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 SONDIR TEST RENCANA PEMBANGUNAN TANGKI PERTAMINA TBBM TEMBILAHAN LAY OUT : PERTAMINA TBBM TEMBILAHAN RIAU Depth (M) DATE : 11/01/2020 TESTED : MASWAN CAPACITY : 3.50 Ton CPT-8 SOIL & ROCK INVESTIGATION LOCATION REV. : 0 PAGES : 44 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INHIL - Cone Resistant Total Resistant Skin Friction Skin Friction Total Skin Friction Local Skin Friction (CR) Kg/Cm2 (TR) Kg/Cm2 (SF) Kg/Cm2 x 20/10 Kg/Cm (TSF) Kg/Cm (LSF) Kg/Cm 7.00 7.20 7.40 7.60 7.80 8.00 8.20 8.40 8.60 8.80 9.00 9.20 9.40 9.60 9.80 10.00 10.20 10.40 10.60 10.80 11.00 11.20 11.40 11.60 11.80 12.00 12.20 12.40 12.60 12.80 13.00 13.20 13.40 13.60 13.80 2 2 2 3 3 2 2 LABORATORIUM TEKNIK SIPIL CV. JAYA CORINDO DESIGN MEDAN 4 4 4 5 5 4 4 2 2 2 2 2 2 2 Checked by 4 4 4 4 4 4 4 TARBIYATNO, MT 4 8 12 16 20 24 28 0.20 0.20 0.20 0.20 0.20 0.20 0.20 Page : 2/4 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 SONDIR TEST RENCANA PEMBANGUNAN TANGKI PERTAMINA TBBM TEMBILAHAN LAY OUT : PERTAMINA TBBM TEMBILAHAN RIAU Depth (M) DATE : 11/01/2020 TESTED : MASWAN CAPACITY : 3.50 Ton CPT-8 SOIL & ROCK INVESTIGATION LOCATION REV. : 0 PAGES : 45 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INHIL - Cone Resistant Total Resistant Skin Friction Skin Friction Total Skin Friction Local Skin Friction (CR) Kg/Cm2 (TR) Kg/Cm2 (SF) Kg/Cm2 x 20/10 Kg/Cm (TSF) Kg/Cm (LSF) Kg/Cm 14.00 14.20 14.40 14.60 14.80 15.00 15.20 15.40 15.60 15.80 16.00 16.20 16.40 16.60 16.80 17.00 17.20 17.40 17.60 17.80 18.00 18.20 18.40 18.60 18.80 19.00 19.20 19.40 19.60 19.80 20.00 20.20 20.40 20.60 20.80 2 4 4 4 6 7 2 2 3 3 3 2 2 2 2 2 4 4 3 3 3 9 13 19 23 24 10 10 17 20 22 8 12 17 19 LABORATORIUM TEKNIK SIPIL CV. JAYA CORINDO DESIGN MEDAN 4 6 6 6 8 9 4 4 5 5 5 4 4 4 4 4 6 6 5 5 5 11 15 21 26 27 12 12 20 23 25 11 14 20 21 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 2 2 3 3 3 3 2 3 2 Checked by 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 4 4 6 6 6 6 4 6 4 TARBIYATNO, MT 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 104 108 112 116 120 124 130 136 140 144 150 156 162 168 172 178 182 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.30 0.30 0.20 0.20 0.30 0.30 0.30 0.30 0.20 0.30 0.20 Page : 3/4 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 RENCANA PEMBANGUNAN TANGKI PERTAMINA TBBM TEMBILAHAN SONDIR TEST LAY OUT : PERTAMINA TBBM TEMBILAHAN RIAU Depth (M) DATE : 11/01/2020 TESTED : MASWAN CAPACITY : 3.50 Ton CPT-8 SOIL & ROCK INVESTIGATION LOCATION REV. : 0 PAGES : 46 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INHIL - Cone Resistant Total Resistant Skin Friction Skin Friction Total Skin Friction Local Skin Friction (CR) Kg/Cm2 (TR) Kg/Cm2 (SF) Kg/Cm2 x 20/10 Kg/Cm (TSF) Kg/Cm (LSF) Kg/Cm 21.00 21.20 21.40 21.60 21.80 22.00 22.20 22.40 22.60 22.80 23.00 23.20 23.40 23.60 23.80 24.00 24.20 24.40 24.60 24.80 25.00 25.20 25.40 25.60 25.80 26.00 26.20 26.40 26.60 26.80 27.00 27.20 27.40 27.60 27.80 20 10 13 17 19 22 18 20 31 34 37 20 34 37 39 42 53 54 20 22 24 41 43 31 33 37 58 59 61 62 66 71 73 92 96 LABORATORIUM TEKNIK SIPIL CV. JAYA CORINDO DESIGN MEDAN 23 12 15 20 21 24 21 22 35 37 40 22 37 40 42 45 55 57 22 24 26 44 47 35 36 40 61 62 64 66 70 75 80 100 102 3 2 2 3 2 2 3 2 4 3 3 2 3 3 3 3 2 3 2 2 2 3 4 4 3 3 3 3 3 4 4 4 7 8 6 Checked by 6 4 4 6 4 4 6 4 8 6 6 4 6 6 6 6 4 6 4 4 4 6 8 8 6 6 6 6 6 8 8 8 14 16 12 TARBIYATNO, MT 188 192 196 202 206 210 216 220 228 234 240 244 250 256 262 268 272 278 282 286 290 296 304 312 318 324 330 336 342 350 358 366 380 396 408 0.30 0.20 0.20 0.30 0.20 0.20 0.30 0.20 0.40 0.30 0.30 0.20 0.30 0.30 0.30 0.30 0.20 0.30 0.20 0.20 0.20 0.30 0.40 0.40 0.30 0.30 0.30 0.30 0.30 0.40 0.40 0.40 0.70 0.80 0.60 Page : 4/4 CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 RENCANA PEMBANGUNAN TANGKI PERTAMINA TBBM TEMBILAHAN SONDIR TEST LAY OUT : PERTAMINA TBBM TEMBILAHAN RIAU Depth (M) 28.00 28.20 28.40 28.60 28.80 29.00 29.20 29.40 29.60 29.80 30.00 30.20 30.40 30.60 30.80 31.00 31.20 31.40 31.60 31.80 32.00 32.20 32.40 32.60 32.80 33.00 33.20 33.40 33.60 33.80 34.00 34.20 34.40 34.60 34.80 DATE : 11/01/2020 TESTED : MASWAN CAPACITY : 3.50 Ton CPT-8 SOIL & ROCK INVESTIGATION LOCATION REV. : 0 PAGES : 47 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INHIL - Cone Resistant Total Resistant Skin Friction Skin Friction Total Skin Friction Local Skin Friction (CR) Kg/Cm2 (TR) Kg/Cm2 (SF) Kg/Cm2 x 20/10 Kg/Cm (TSF) Kg/Cm (LSF) Kg/Cm 102 110 8 16 424 107 115 8 16 440 121 130 9 18 458 98 105 7 14 472 99 106 7 14 486 101 110 9 18 504 110 119 9 18 522 123 133 10 20 542 100 109 9 18 560 121 130 9 18 578 124 134 10 20 598 136 146 10 20 618 139 149 10 20 638 144 154 10 20 658 146 156 10 20 678 148 158 10 20 698 143 153 10 20 718 148 158 10 20 738 149 159 10 20 758 149 159 10 20 778 150 160 10 20 798 157 167 10 20 818 ============= ======================== =========== =========== - LABORATORIUM TEKNIK SIPIL CV. JAYA CORINDO DESIGN MEDAN Checked by TARBIYATNO, MT 0.80 0.80 0.90 0.70 0.70 0.90 0.90 1.00 0.90 0.90 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ========== Page : 5/4 CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 3.3.3. REV. : 0 PAGES : 48 of 64 ANALISIS PONDASI DALAM BERDASARKAN KORELASI NILAI N-SPT 3.3.3.1. Kapasitas Aksial Tiang Tunggal Secara umum, kapasitas daya dukung ultimate aksial dari pondasi tiang, dapat diperoleh dengan menjumlahkan kapasitas daya dukung ujung dan tahanan geser selimut tiang. Kapasitas daya dukung tersebut dapat ditulis seperti terlihat pada persamaan dibawah ini. Qu = Qp + Qs Dimana: Qu = kapasitas daya dukung ultimate Qp = kapasitas daya dukung ujung ultimate Qs = tahanan geser selimut tiang ultimate Gambar 3-20 Daya Dukung Aksial Pondasi Tiang 3.1.1.1 Tahanan Geser Selimu Tiang Tahanan geser selimut tiang ultimate dari pondasi pada tanah c-φ dapat dihitung berdasarkan persamaan sebagai berikut: Qs Dimana: = Qsc + Qsφ CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 49 of 64 Qs = tahanan geser selimut tiang ultimate Qsc = kontribusi dari kohesi tanah, c (pada tanah lempung) Qsφ = kontribusi dari sudut geser dalam tanah, φ (pada tanah pasir) 3.1.1.2 Tahanan Geser Selimut pada Tanah Lempung Secara umum, kontribusi kohesi tanah untuk tahanan geser selimut tiang ultimate dapat diperoleh dengan menggunakan persamaan sebagai berikut: Qsc cu i li p Dimana: α = faktor adhesi cu-i = kohesi tanah undrained pada lapisan ke-i li = panjang tiang pada lapisan ke-i p = keliling tiang Besarnya nilai faktor adhesi, α, khususnya untuk tiang pancang, dapat ditentukan Adhesion Factor dengan menggunakan metoda dari API sebagai berikut: Undrained Shear Strength (Cu) in kN/m 2 Gambar 3-21 Faktor adhesi API metode 2 (1986) CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 50 of 64 3.3.3.2. Tahanan Geser Selimut pada Tanah Pasir Kontribusi dari sudut geser dalam tanah, φ, untuk tahanan geser selimut ultimate dapat diperoleh dengan menggunakan persamaan sebagai berikut: n QS f i li p i 1 dimana: fi = Ko-i .σ’v-i . tan ( 2/3 φi) Ko-i = koefisien tekanan tanah lateral pada lapisan ke-i = 1 – sin φ σ’v-i = tegangan vertikal efektif pada tengah lapisan ke-i φi = sudut geser dalam tanah pada lapisan ke-i li = panjang tiang pada lapisan ke-i p = keliling tiang Karena kesulitan yang timbul dalam menentukan besarnya harga sudut geser dalam, φ, maka untuk perhitungan tahanan geser selimut dapat digunakan berdasarkan nilai NSPT. Berdasarkan NavDoc, besarnya tahanan geser untuk tiang pancang adalah: fs N tsf 0 .2 N t / m 2 f l 50 dimana: N = nilai rata-rata standard penetration test sepanjang selimut tiang fs = tahanan geser selimut ultimate, untuk tiang pancang dalam tsf fl = batas tahanan selimut, untuk tiang pancang fl = 1 tsf CALCULATION DOCUMENT NO. REV. : 0 PAGES : 51 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 3.1.1.3 Tahanan Ujung Tiang Secara umum, kapasitas daya dukung ujung pondasi tiang yang terletak pada lapisan tanah c-φ dapat dihitung berdasarkan persamaan sebagai berikut: Qp = Ap (c Nc* + q’ Nq*) Dimana: Ap = luas penampang bagian ujung tiang c = kohesi tanah pada bagian ujung tiang q’ = tegangan vertikal efektif pada daerah ujung tiang Nc*, Nq* = Faktor daya dukung Tahanan ujung tiang diperhitungkan untuk dua jenis tanah, yaitu pasir dan lempung. Rumus perhitungan daya dukung ujung untuk tiang ditunjukkan pada table dibawah ini, Jenis Tanah Rumus Dasar Perhitungan Tanah Kohesif (clay) Qb = 9 x Cu x Ab L/D > 2.5 (AASHTO) Tanah Pasiran Qb = σv x Nq x Ab Data φ Qb = ɳ x N x Ab Data N-SPT Qb = (Cu x Nc + q x Nq) x Ap (data φ- Meyerhoff) Tanah c-φ 3.3.3.3. Kapasitas Tarik Tiang Desain tiang terhadap beban tarik sangat penting untuk struktur yang mengalami beban seismik. Pada beberapa kondisi, kapasitas tarik tiang menentukan kedalaman penetrasi minimum yang diperlukan. Menurut Nicola dan Randolph (1993), pada tanah kohesif berbutir halus (fine grained), dimana pembebanan diasumsikan terjadi pada kondisi undrained, tahanan sisi tiang pada CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 52 of 64 kondisi tekan dihitung sama dengan kondisi tarik. Sedangkan pada tanah non-kohesif atau tanah teralirkan bebas (free-draining), Nicola dan Randolph (1993) menyatakan bahwa tahanan sisi biasanya dihitung 70% dari tahanan sisi untuk kondisi tekan. 3.3.3.4. Kapasitas Daya Dukung Tiang Ijin Daya dukung ijin tiang adalah daya dukung ultimate dibagi dengan angka keamanan, atau dapat juga ditulis dalam bentuk seperti berikut ini: Qall Qult SF Pada umumnya, angka keamanan yang sering digunakan berkisar antara 2 – 4 untuk kondisi operasional atau untuk beban yang bekerja selama operasi. Menurut Tomlinson (1977), penentuan kapasitas ijin dari tiang adalah seperti ditunjukkan pada persamaan berikut: Kapasitasijin tiang Kapasitasultimate tiang 2,5 Dari persamaan di atas, angka keamanan yang digunakan untuk desain pondasi tiang adalah 2,5. OCDI – Technical Standards and Commentaries for Port and Harbour Facilities in Japan. 2009, menyarankan penggunaan angka keamanan sebesar 2.5 untuk kapasitas tiang. Kisaran angka keamanan tergantung pada reliabilitas dari metoda analisis statik yang digunakan dengan pertimbangan-pertimbangan sebagai berikut: Tingkat keyakinan terhadap parameter-parameter tanah yang digunakan. Keseragaman lapisan tanah. Efek dan konsistensi dari metoda instalasi tiang yang digunakan. CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 53 of 64 Tingkat pengawasan saat konstruksi. Dilakukan pengujian terhadap tiang baik dengan metoda Pile Driving Analaysis (PDA) test. 3.3.4. ANALISA PONDASI CATWALK 3.3.4.1. Analisis Pondasi Catwalk Berdasarkan hasil analisis struktur pada bab sebelumnya, rangkuman hasil analisis struktur adalah sebagai berikut: SPP 609 T9.53mm Axial Compression, Pc = 301.465 KN Axial Tension, Pt = 92.68 KN Lateral, H = 32.60 KN Dari hasil analisa joint reaksi diatas, selanjutnya akan digunakan sebagai beban dalam melakukan analisa kapasitas tiang pancang pada Tiang Pancang Catwalk SPP609 T9.53 mm, berikut ini merupakan hasil analisa terhadap kapasitas tiang, Detail tiang pancang dan titik soil sebagai berikut: SPP 609 T9.53 mm Type Tiang = SPP609 T9.53 mm Elevasi seabed = 8.2 m Panjang tiang tertanam = 44 m Elevasi cut off = -0.203 m Panjang tiang total = 44 + (8.2 -0.203) = 52 m CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 Titik soil acuan STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 54 of 64 = BH-05 & CPT-S8 3.3.4.2. Analisis Daya Dukung Axial Tiang BH-02 Berikut ini merupakan nilai daya dukung dukung tiang Tekan berdasarkan titik borlog BH-05,CPT-S8, menggunakan tiang SPP 609 T9.53 mm. - 3 1,020 kg/m Po 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 17.50 Nk cu average = ( kg/cm2 ) ( kg/cm2 ) 0.72 2.86 0.72 2.88 0.81 2.90 0.63 2.92 0.63 2.94 0.81 2.96 0.81 2.98 0.90 3.00 0.81 3.02 0.81 3.04 0.90 3.06 0.90 3.08 0.90 3.10 0.90 3.12 0.90 3.14 0.90 3.16 fs (use) 3.50 ( kg/cm2 ) 5.67 5.95 6.75 5.43 5.49 5.60 6.12 6.86 5.54 6.74 6.91 7.60 7.77 8.05 8.16 8.28 cu K ( cm ) 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 191.51 0.0010 kg/cm3 cone resistance from CPT data sleeve friction from CPT data * 0.09 (shaft of cone) overburden pressure point where qc is measured as previously defined and used cone factor (a constant for that soil). Refer to Bowles, most values are in the 15 to 20 range = 17.50 = = qc = fs (use) = Po = Nk = - wsoil 8.00 8.00 9.00 7.00 7.00 9.00 9.00 10.00 9.00 9.00 10.00 10.00 10.00 10.00 10.00 10.00 ( kg/cm2 ) 102.00 107.00 121.00 98.00 99.00 101.00 110.00 123.00 100.00 121.00 124.00 136.00 139.00 144.00 146.00 148.00 - fs qc ( cm2 ) 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 3,830.23 ( kg ) 2,757.77 2,757.77 3,102.49 2,413.04 2,413.04 3,102.49 3,102.49 3,447.21 3,102.49 3,102.49 3,447.21 3,447.21 3,447.21 3,447.21 3,447.21 3,447.21 Qs 73,080.78 75,838.55 78,941.04 81,354.08 83,767.12 86,869.61 89,972.10 93,419.30 96,521.79 99,624.28 103,071.48 106,518.69 109,965.90 113,413.10 116,860.31 120,307.52 ( kg ) Σ Qs 148,816.37 156,290.81 177,274.36 142,720.45 144,190.85 147,162.25 160,640.74 180,123.28 145,569.38 177,060.01 181,532.43 199,513.96 203,986.37 211,460.82 214,432.22 217,403.62 ( kg ) Qt FRICTION RESISTANCE EARING RESIST K As Ae Qs Qt Qall Qtall = = = = = = = Permanent Qall Qtall ( kN ) ( kN ) 723.12 283.12 757.11 292.59 837.28 303.21 730.03 311.54 742.85 319.87 762.98 330.49 818.13 341.11 894.45 352.89 789.49 363.51 904.68 374.13 930.96 385.91 1,002.27 397.68 1,028.56 409.45 1,064.84 421.23 1,086.12 433.00 1,107.40 444.77 Temporary Qall Qtall ( kN ) ( kN ) 940.06 368.05 984.24 380.37 1,088.46 394.18 949.03 405.00 965.71 415.83 991.87 429.64 1,063.57 443.45 1,162.78 458.75 1,026.34 472.56 1,176.09 486.38 1,210.25 501.68 1,302.96 516.98 1,337.12 532.29 1,384.30 547.59 1,411.96 562.90 1,439.62 578.20 PILE CAPACITY (Axial) pile perimeter (= π * D) pile shaft area (= K * (zi - zi-1)) pile tip area (= 0.25 * π * D^2) shaft resistance of the pile due to skin friction (= Σ (fs * As)) tip resistance of the pile due to end bearing (= cu * Ae * 9) allowable compression capacity (= (Σ Qs + Qt)/SF ; SF = 3) allowable tension capacity (= Σ Qs/SF ; SF = 3) Cu = undrained shear strength (= (qc - Po) / Nk) ( cm2 ) 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 2,918.64 OD = 60.96 cm ID = 59.05 cm W = 141.1 kg/m As Ae Assu REMA RKS TMB-CAL-80-204-A4 qc average = Depth z (meter) 0.00 28.00 28.20 28.40 28.60 28.80 29.00 29.20 29.40 29.60 29.80 30.00 30.20 30.40 30.60 30.80 31.00 PILE DATA East = 102° 56ʹ 32.6652ʺ SINGLE PILE CAPACITY (NPS 24") DOCUMENT NO. Note : (meter) 0.000 -28.000 -28.200 -28.400 -28.600 -28.800 -29.000 -29.200 -29.400 -29.600 -29.800 -30.000 -30.200 -30.400 -30.600 -30.800 -31.000 Elev. CPT DATA Point No. : CPT S-8 Coordinate: North = 0°29ʹ 54.7692ʺ Elevation : 0.000 m CALCULATION STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 55 of 64 Tabel 3-8 Daya Dukung Pondasi Tiang Pancang Baja – BH-02 dengan data sondir S-8 CALCULATION DOCUMENT NO. REV. : 0 PAGES : 56 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 Perhitungan daya dukung tiang Pancang Penetration Test tunggal berdasarkan data Standard (SPT) yang di rumuskan oleh Meyerhoff adalah sebagai berikut : Pu = 40. N. Ab + n. As / 5 Dimana : Pu N n Ab As = = = = = Ultimate Load Capacity (ton) Standard Penetration Number at pile base (blows) Average Value of N along pile shaft (blows) Area of Pile Base (m2) Gross surface area of shaft (m2) Lokasi : BH-5 Dipilih : - Lubang Bor BH – 5 - Diameter tiang = 609 mm ( penampang Bulat ) - SPT pada kedalaman 42,00 meter - N = 14 blows - n = 6.6 blows Pu = = = = 40. N. Ab + n. As / 5 40. 14. 0,291 + 6,6. 1,913. 42 / 5 285,865 + 170 269,1787 ton / tiang tunggal Pa = Pu / SF, SF = Safety Factor, diambil = 2,5 Pa = 269,1787 / 2,5 = 107,6715 ton/ tiang tunggal = 1055,902 kN/ tiang tunggal CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 57 of 64 SPP 609.6 T 9.53 mm Kapasitas Tekan Pc,max = 30.741Ton = 301.465 KN (Tekan) Pall,c = 1055,902 KN , berdasarkan Single Pile capacity, (SFc = 2.5 berdasarkan OCDI) P = 301.465 KN (Tekan) < 1055,9 KN…. OK! Kapasitas Tarik Pt,max = 92.68 KN (Tarik) Pt,all = 444.77 kN , berdasarkan BH-03, (SFt = 2.5 berdasarkan OCDI) P = 92.68 KN (Tarik) < 444.77 KN…. OK! CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 58 of 64 3.3.4.3. Analisis Daya Dukung Lateral Analisa terhadap daya dukung lateral pada tiang SPP 609 T9.53 mm adalah sebagai berikut, SPP 609 T 9.53 mm Beban lateral maksimum pada tiang, H = 92.68 KN Gambar 3-22 Defleksi vs Kedalaman Tiang Catwalk – SPP609 T9.53 mm – BH-05 Berdasarkan hasil perhitungan, defleksi lateral maksimum yang terjadi pada tiang adalah sebesar 1.31 cm lebih kecil dari batas defleksi lateral yang diijinkan 1” (2.54 cm) → Defleksi aktual 1.32 cm < Defleksi diijinkan 2.54 cm (Kondisi Baik). CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 STEEL PIPE PILE FOUNDATION CATWALK RECOVER REV. : 0 PAGES : 59 of 64 3.3.4.4. Analisis Settlement Tiang SPP 609 T9.53 mm Beban Maksimum yang diberikan pada tiang Pc,max = 926.9862 KN (Tekan) Gambar 3-23 Beban vs penurunan Tiang Catwalk – SPP609dolp T9.53 mm – BH-05 Penurunan maksimum yang mengacu pada beban tekan pondasi tiang adalah 0.0103 cm. Dengan batasan maksimum penurunan tiang adalah 1’’ (2.54 cm), → Penurunan aktual 0.1156 cm < Penurunan diijinkan 2.54 cm (Kondisi Baik). CALCULATION DOCUMENT NO. REV. : 0 PAGES : 60 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 3.4. ANALISIS STRUKTUR ATAS 3.4.1. PILECAP BETON PADA CATWALK Pelat lantai direncanakan memiliki perilaku sebagai pilecap. Dengan pembebanan diatas, diperoleh hasil analisis struktur sebagai berikut: Tabel 3-9 Gaya Dalam Pilecap Struktur Catwalk Tiang TABEL: Beam Force Case Type Step Type P Text Text Ton Min -0.015 Service Max -0.014 PILCAP T.500 mm Min -0.019 Ultmate Max -0.018 Frame Text V2 M22 M33 Ton Ton-m/m Ton-m/m 1.671 -0.012 -14.639 13.069 0.005 14.305 3.327 -0.017 -22.613 20.019 0.008 22.162 Hasil analisis struktur diatas dapat digunakan untuk perencanaan tulangan pada pilecap. Perhitungan kebutuhan tulangan dapat dilihat sebagai berikut : CONCRETE DESIGN One Way Shear Force Foundation width Foundation thickness Concrete strength Yield Strength of rebar Bottom concrete cover Diameter Bar use Effective depth = = = = = = = Vu =Maximum shear at edge of pedestal, Vu = 0.5 x qu x s = Maximum force to be used for concrete design, Pa = qu due to pile cap = 30.74 Pa x b Ap 9.79 = pile spacing = Tributary area of pile, Ap = 1.30 0.5 25.00 400.00 75.00 25.00 400 m m MPa Mpa mm mm mm 9.79 T T T/m A B T/m 2m 3.14 m2 shear force max. due to one way ∅∗ √ 𝑓^′ 𝑐 ∗𝐵∗𝑑 /6 Concrete strength againt shear ∅Vc = = = ∅Vc > Vu 250000 25.48 OK N T CALCULATION DOCUMENT NO. REV. : 0 PAGES : 61 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 Two way Shear Force bo Two way shear determined due to Load combination 201 Foundation width Foundation thickness Concrete strength Yield Strength of rebar Bottom concrete cover Diameter Bar use Effective depth bo βc αs Wu = = = = = = = = = = = 1.30 0.5 25.00 400.00 75.00 25.00 412.5 3209.136896 1 40 603.74 m m MPa Mpa mm mm mm mm 0.5d 0.4 + (2*0.5d) d=0.415 KN T m2 = Diameter of pile + 2*1/2*deff m = 1.02 = 61.543 = 1.69 Foundation area Diameter of punching area Punching Area = 0.8191 Vu = 1.4 x Reaction pile compress = 93.60 Concrete strength against shear Vc 1 = Vc 1 = = = Vc 2 = m2 3,309,422 , T N T T 337.35 253.0139468 ((𝛼𝑠∗𝑑)/𝑏0+2)*(√(𝑓^′ 𝑐)∗𝑏0∗𝑑)/12 Vc 2 = Vc 3 = Vc 3 Vc = = = = Pile Dia.0.4 (1+2/𝛽𝑐) (√(𝑓^′ 𝑐)∗𝑏0∗𝑑)/6 = = minVc Reinfrocement 0.4 0.5d punching area 3939078.308 401.5370344 301.1527758 N T 1/3*√(f𝑐)*bo*d 2206281.616 224.901286 168.6759645 168.67596 > N T T VU 93.60 OK qU b= 1m 2 Maximum moment at center of slab, Mu = 0.125 x qu x s 4.893 Tm A Ratio of reinforcement cal : m = fy = 18.824 0.85 fc' Ru = Mu = 33.976 with = 0.9 2 bde cal = 1/m ( 1- (1 - 2 m Ru / fy ) 1/2 ) Mmax=1/8 qu l^2 B CALCULATION DOCUMENT NO. REV. : 0 PAGES : 62 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 = 0.00300 Maximum ratio of reinforcement max : bal = 0.85 x xfc' 6,300 fy 6,300 + fy = 0.0425 max = 0.75 x bal = 0.0318 Minimum ratio of reinforcement min : min = 0.00120 Caused of cal > min, used cal cal = Reinforcement that use is 0.00300 Total Area of flexural reinforcement, As req. = x b x de 2 = Used bar D25, 12.392 cm / m width of cap therefore the area of steel for one bar, As = Number of bar = 4.909 4 cm 2 2 2 As provided = 19.635 cm > As req (12.392 cm ) … OK Use: for top and bottom D 25-250 mm CALCULATION DOCUMENT NO. TMB-CAL-80-204-A4 3.4.2. REV. : 0 PAGES : 63 of 64 STEEL PIPE PILE FOUNDATION CATWALK RECOVER INFILL CONCRETE PADA PONDASI CATWALK Penulangan infill berdasarkan gaya ultimate dari tiang, berikut ini merupakan gaya ultimate pada tiang. Gaya Tekan Case Type Step Type P Text Text Text kN Infill SPP 609 Ultimate Min -91.914 Max 273.995 Load Data Gaya Tarik Frame Pt.ultimit = = Pc.ultimit = = Data Material Kuat tekan Beton f’c = Tegangan Leleh Baja f’y = Tegangan putus baja fu = Diameter tulangan D = Jumlah Tulangan n = Kuat lekatan beton terhadap tulangan = Konstanta beton k = 91.914 91914 273.995 273995 kN N kN N 25 MPa 400 MPa 560 MPa 13 mm 10 2.2 MPa 0.25 Data Tiang pancang Kedalaman infill concrete L = 1500 mm Inside diameter tiang ID = 691.94 mm Kuat lekatan beton terhadap baja kondisi tarik = 1.5 MPa ft Kuat lekatan beton terhadap baja kondisi tekan = 1.9 MPa ftc Perhitungan kapasitas Tarik beton = 4891035.647 N = 4891 kN PT = π . ID . L . ft Berdasarkan perhitungan diatas, kuat Tarik lekatan beton terhadap baja adalah Condition should be fulfilled: P > Pu 4891 kN > 91.9 kN OK Perhitungan kapasitas Tekan beton CALCULATION DOCUMENT NO. STEEL PIPE PILE FOUNDATION CATWALK RECOVER TMB-CAL-80-204-A4 REV. : 0 PAGES : 64 of 64 PC = π . ID . L . ftc = 6.195,311 N = 6.195 kN Berdasarkan perhitungan diatas, kuat tekan lekatan beton terhadap baja adalah Condition should be fulfilled: P > Pu 6.195 kN > 273,9 kN OK Perhitungan kapasitas Tarik tulangan Gaya Tarik per tiap tulangan Tult = Tegangan putus tulangan Luas penampang tulangan Ab = Factor reduksi Ø = Kuat Tarik nominal tulangan Nsa = 9191 Tul < Nsa < 55734 Pt /nt b = 9191,4N = 560 MPa = 132.7 mm2 fu π/4 * d2 0.75 Ø * Ab * fub = 55734 N OK Perhitungan Panjang penyaluran Tulangan LD1 LD2 = = = 1500 mm b 0.04 . fu . D = 291.2 mm Tulangan infill concrete yang digunakan pada Jetty Head dengan tiang SPP ∅ 609.6 t=9.53 mm adalah 10 D13.