1.13 PLANTING and its density as to be enough to have the area fully covered. Contractor to include the sedum price in other plants items specified in the BOQ. The estimated length for fire rated cable from MSDB to FFP is 100m, so: • 1x185mm2 is 400m considering spare length around +20% • 1x95mm2 is 300m considering spare length around +20% These types of cables shall be included in the Scope of Work. Any difference in quantities should be considered in the unit price rate for the provided tender quantities. The type of cable is the same in drawings and BoQ. In schematic drawings it’s shown the code of specific cable used for calculation. In the BoQ is shown the general description of cable with the same characteristics, without shown the specific code. RZ1-K: LV CABLE XLPE INSULATION SZ1-K: LV CABLE FIRE RESISTANT In the drawing each lighting fixture is described by its PROJECT CODE and INSTALLATION INFORMATION For example, project code LCF31 C is a CEILING installation and LFC31 D is an installation that can be described only in DETAIL. You can find this information under the Lighting Legend in the Lighting Design tables. As for LFC31 is the linear fixture proposed to illuminate all the musharabia of the facade and should be positioned in the lower and internal part of it as to wall wash the facade. As for LFC31 Ceiling Installation is only present in the L02 001. Our estimated length for Fire rated cable (3(1x185) +(1x95) +(1G95) from MSDB to firefighting pumps are 100 meters, since this is 3 sets, both 1x185mm2 and 1x95mm2 shall be the same length, plus 300 meters also for (1G95) however in the BOQ the 1x185mm2 is 250 meters and only 200 meters for 1x95mm2, please verify. 47 Kindly verify the code provided in the BOQ for cables vs in the drawing are not matching. 48 In lighting system, there are type of lighting fixture like LFC31-C which is installed on ceiling, but may we know what is LFC31-D? this code is not available in the installation info or lighting legend, kindly enlighten us. 49 Restaurant to give a similar effect over the musharabia that is present on the ceiling . Your observation is right there is code mistake in the area L00 005 Restaurant entrance where erroneously the code is LFD80. Ignore and substitute with LFB80 The secondary line and related junction boxes are not shown. The number is estimated based on the area to cover. The different type of lighting point is considered in BoQ based on the different type of switching mode, shown on the drawings in the same area (i.e. in the room in which it’s provided a push button, all the lighting points of the room are considered in BoQ with item 26.7.3) For HVAC specs. refer to TD.TLM.01_SPECIFICATIONS.pdf” same air flow value just different units. 1 m3/hr = 0.278 L/sec Kindy check the quantity of Cove fixture – LFB80 because the numbers in the BOQ are 5.5, Also this item is not in the drawing. 50 There are 150 nos. of 150x110x70 mm boxes and 150 also for 300x220x120 mm In the BOQ S.N 26.6.16 & 17, however not shown in the drawing, please verify. 51 In wiring devices, lighting points of S. No 26.7.1,2 & 3 are not reflected in the drawing, kindly verify. 52 Mechanical Equipment’s specification not indicated in the tender drawing. 53 Machine HVAC Equipment in tender drawing is indicated as cubic meter per hour while in BOQ it is Liters per second. 54