New Leader of Marking Technology! + LP7200 Ink Jet Printer Operating Manual Fine & Clear Dots Easy Operating High Speed Print Smallest Printhead LP7200+ INK JET PRINTER 1. EXPLANATION OF PRODUCT'S NAME 1-1. Key pad A : View finder back light graphic LCD B : Model name F1~F5 : Function key ESC : Escape key CAPS : Caps key SHIFT : Shift key SAVE : Enter key DOT SIZE, PURGE, PRINT SPEED, PRINT DELAY : Direct movement key A~Z, 0~9 : Numbers, Characters key 1 LP7200+ INK JET PRINTER 1-2. Control unit 1-3. Size of products 2 LP7200+ INK JET PRINTER 1-4. Product's specification ITEMS Character LP-7100+plus LP-7200+plus 5x5, 5x7 or 10x7 One line Font(HXW) Character Height Print Speed 5x5, 5x7 or 10x7 Two lines 10x16, 20x16 One line 26mm "P" Type 63mm "P" Type 14or24mm "C" T ype 33or60mm "C" T ype Up to 170 Meters/Min(Max) "P" Type Up to 120 Meters/Min(Max) "C" Type Data Storage Text 1000 Chracters/1Line (7Dots, 16Dots) Memory Location 100 Each Memory Storage Location Custom Characters 7 or 16(H)X122dots(W) 50 each Graphic data LCD Display 64(H) X 128(V) Dots Back Light Graphic LCD Font reduction Font Reduction 0,1,2 or 3 Changeable Print Function Date, Real Time, Expiry date, Shift Time, Up-Counter Single/ Double/ Light print, Repeat print, Print direction Odd/ Even Counter, Repeat Counter Hot key Function Dot size, Print speed, Print delay, Purge Keypad Tone up Keypad 59keys, Dialogue Menu Ink Container 2.5 Liters Stainless Steel Container(standard) 5, 14Liters container(option) Inks M.E.K Base "P" type Water base "C" type Input Signal Photocell for Printhout, Speed Encoder Power 90-250V AC 60Hz Interface RS485 Operating Temp 5-45℃ 3 LP7200+ INK JET PRINTER 2. BASIC INSTALLATION OF PRODUCT 2-1. Installation using one printhead You could install a printhead using a basic bracket as below picture and a printhead could be mounted on the side, the top and the bottom. 2-2. Installation using two printheads You could install 2 printheads with using basic brackets in order to mark on both sides as below picture and printheads could be mounted on the side, the top and the bottom. 4 LP7200+ INK JET PRINTER 2-3.Basic installation of container for ink supply You could install a standard container for ink supply shown as below. The maximum permissible inner pressure of the container is 2kg/cm² and should be careful not to exceed it. For optimum marking, you have to install the container within 1 meter from the printhead and adjust inner pressure of the container within 0.2~0.3kg. If inner pressure is too high, it could damage printhead and could not get good marking results. if inner pressure is too low,marking quality might not be good. For ink line of the container, we recommend that the line should be installed within 10m. 5 LP7200+ INK JET PRINTER 3. CONNECTING TO A CONNECTOR 3-1. Connecting to detective the signal of an object By using photo sensor or mechanical switch as an outer signal for operating of the printer, the printer is connected to I/o signal. Connecting to printing signal by using photo sensor The photo sensor operating to DC24V should be used. Photo sensor can be used by connecting to "COMM" port on a control panel as below picture. COMM PORT PIN NO SIGNAL 1 2 3 4 5 0V 6 7 +24V 8 9 PRINTOUT SIGNAL No.1 3-2. Connecting to printing signal by using mechanical switch You could print contents out by using mechanical switch (I/O Signal). Mechanical switch can be used by connecting to "COMM" PORT on a control panel as below picture. COMM PORT PIN NO SIGNAL 1 2 3 4 5 0V 6 7 8 9 PRINTOUT SIGNAL No.1 6 LP7200+ INK JET PRINTER 3-3. Connecting to a speed encoder Connecting to a speed encoder is adoptable to mark a character on a product that moving speed of a object is not regular or on a continuous product. The marking speed is adjusted according to purse occurred in encoder. Speed encoder should be used for DC24V. Speed Encoder can be used by connecting to "COMM" port on the front control panel as below. COMM PORT PIN NO SIGNAL 1 2 3 4 5 0V 6 7 24 V 8 Encoder Out Signal 9 3-4. How to select a speed encoder General specification : Use of an encoder enables letters to be marked correctly if only pulse and wheel diameter are applied properly according to the applying conditions of font reduce as below picture. FONT REDUCTION : 0 ENCODER PULSE : 60 WHEEL DIAMETER : 60 mm The normal printing-out status of 26 or 63mm Printhead ● ● ● ● ● ● ● ●●●●● ● ● ● ● On an occasion of FONT REDUCE application : When height of a letter is reduced into a half size in conformity with the font reduction FONT REDUCTION : 1, 2, 3, 4, 5 ENCODER PULSE : 120 WHEEL DIAMETER : 60 mm 7 LP7200+ INK JET PRINTER ● ● ● ● ● ● ● ●●●●● ● ● ● ● The printing-out status applied the font reduction of 26mm or 63mm printhead. Because the height of a letter has to get short and width of a letter has to get narrow, encoder pulse must be controlled properly. * When FONT REDUCE is applied, proper marking letter is printed by increasing encoder pulse or by decreasing wheel diameter at the rate of a letter's height as above. * On an occasion of marking in conformity with FONT REDUCE, if the width of a letter is too narrow, FONT TYPE of F2. PRINT SET can be changeable from SINGLE to LIGHT to print. 3-5. Lithium Batteries CAUTION ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. 3-6. Notice on an occasion of an exchange of battery If battery is all discharged, even when the power is turned on, main menu display doesn't show up. If battery is exchanged and the power is turned on while the ESC button is being pressed, LOGO display show up. If you release ESC button about 1sec. later, it passes to main menu display and operates normally. On an occasion of an exchange of battery, use it after initializing the system using F5.INITIALIZE. 8 LP7200+ INK JET PRINTER 1. BASIC COMPONENTS OF PROGRAM 1-1. Initial display INTER MAC +PLUS LP7200 VER6.0 F1 F2 F3 F4 F5 >> MENU << : MEMORY : PRINT : COUNTER : CLOCK : INITIAL 1-2. Function Code of Initial screen F1. MEMORY SET F2. PRINT SET F3. COUNTER SET F4. CLOCK SET F5. INITIAL SET 1-3. Directory of Function Code F1. MEMORY SET 1. WRITE MEMORY MEMORY ADDRESS <00-99> CAPS-KEY SHIFT KEY F1:INS F2:DEL F3:P.H 2. READ MEMORY MEMORY ADDRESS <00-99> CAPS-KEY SHIFT KEY F1:INS F2:DEL F3:P.H 3. FILE DELETE FILE NUMBER : 0 F2. PRINT SET 1. DIRECTION 1. RIGHT 2. LEFT 9 LP7200+ INK JET PRINTER 3. UP SIDE DOWN <R> 4. UP SIDE DOWN <L> BOTH - HEAD1 - HEAD2 P.H SELECT <F2> [SAVE] 2. PRINT DELAY DELAY COLUMN : 00 <0 - 9999> BOTH - HEAD1 - HEAD2 P.H SELECT <F2> [SAVE] 3. PRINT SPEED PRINT SPEED <0 - 60000>msec [SAVE] 4. DOT SIZE DOT SIZE <0 - 200>msec [SAVE] 5. REPEAT PRINT 1.YES 2. NO [SAVE] 6. SPEED ENCODER ENCODER USE ENCODER UNUSE [SAVE] 7. NOZZLE TYPE 1. 1 X 5 2. 2 X 5 3. 1 X 7 4. 2 X 7 5. 1 X 16 [SAVE] 8. FONT TYPE 1. SINGLE <S> 2. DOUBLE<D> 3. LIGHT <L> BOTH - HEAD1 - HEAD2 P.H SELECT <F2> [SAVE] 10 LP7200+ INK JET PRINTER 9. FONT REDUCE 1. 2. 3. 4. 4. 5. FONT FONT FONT FONT FONT FONT <0> <1> <2> <3> <4> <5> BOTH - HEAD1 - HEAD2 P.H SELECT <F2> [SAVE] 0. PASSWORD OPTION 1. NO 2. YES [SAVE] F3. COUNTER SET COUNTER APPLY [C] START 000000000 STOP 000000000 REPEAT COUNT 001 SKIP[0] YES/NO OPT: BASE/ODD/EVEN COUNTER APPLY<C> BOTH - HEAD1 - HEAD2 [SAVE] F4. CLOCK SET 1. REAL TIME CLOCK 1. YEAR <T> : 00 2. MONTH <I> : 00 3. DAY <M> : 00 4. HOUR <H> : 00 5. MINUTE <R> : 00 [SAVE] 2. EXPIRY DATE 1. YEAR <E> : 00 2. MONTH <X> : 00 3. DAY <P> : 00 [SAVE] 11 LP7200+ INK JET PRINTER 3. SHIFT TIME START TIME : <01 : 00> CYCLE TIME <2> HOUR SET : ALPHA/NUM/NAME SHIFT CYCLE APPLY <A> F5. INITIAL SET [SAVE] 1. GRAPHICS EDIT F1: DOT DRAW→MOVE→DELETE MEMORY ADDRESS <100-150> [SAVE] 2. GRAPHICS READ MEMORY ADDRESS <100-150> 3. HEAD PURGE 1. NO 2. YES [SAVE] 4. INITIALIZE PASSWORD : 0 [SAVE] 5. NETWORK SELECT SELECT ID : 1 [SAVE] 6. "O" SELECT SELECT TYPE : 0/0 7. LANGUAGE SELECT 1. ENGLISH 2. SPANISH or OTHER LANGUAGE AVAILABLE 8. MULTI COMM 12 LP7200+ INK JET PRINTER 1-4. Types and functions of possible command for combination @ 000 - 099 : MEMORY combination command @100 - 150 : GRAPHIC combination command @C : Set UP COUNTER @T : Set YY(year) @I : Set MM(month) @M : Set DD(date) @H : Set HH(hour) @R : Set mm(minute) @N : Set ss(second) @E : Set expiry of YY(year) @X : Set expiry of MM(month) @P : Set expiry of DD(date) @A : Set SHIFT CODE @S : Single print command @D : Double print command @L : Light print command @W : Set month name (A to L) 1-5. Definition of menu display If the nozzle type among F2 PRINT SET is not set to 2x5, 2x7, functions such as DIRECTION, PRINT DELAY, FONT REDUCE display only BOTH on a display. (No.2 PRINTHEAD is not displayed on a display) 13 LP7200+ INK JET PRINTER 2. DEFINITION OF PRINT-OUT FONT 2-1. Composition of basic font ● ● ● ● ● ●●●●● ● ● SINGLE PRINT 5 X 5 DOTS MATRIX FONT ● ● ● ● ● ● ● ●●●●● ● ● ● ● SINGLE PRINT 5 X 7 DOTS MATRIX FONT ●● ●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●●●●●●●●●● ●●●●●●●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● SINGLE PRINT 10 X 16 DOTS MATRIX FONT 2-2. Composition of the applied font Example) 5 x 7 Dots font ● ● ●● ● ● ● ● ● ●●●●● ● ● ● ● Single Print@S ●● ● ●● ● ●● ●● ●● ●● ●●●●●●●●●● ●● ●● ●● ●● ● ● ● ● ● ● Double Print@D ● ● ● ● ● ● ● ● Light Print@L 2-3. Composition of up side down font 14 LP7200+ INK JET PRINTER 2-4. Example of composition of the mixed font ●● ●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●●●●●●●●●● ●●●●●●●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ● ●● ● ● ● ● ●●● ● ●● ● ● ● ● ●●●●● ● ● ●●● ● ●●●● ● ● ● ● ● ●● ● ● ●●●●● ●●●●● ● ● ●●●● ● ● ●●●● ● ● ●●●● ●●● ● ● ●●●● ● ● ● ● ●●● ●●●●●●●● ●●●●●●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●●●●●●●● ●●●●●●●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●●●●●●●●● ●●●●●●●● Input : Use a combination command after using Nozzle Type <1 x 16> 16DOT PRINTHEAD. Reference : As above, on an occasion of using 16 dot font following 2x7 dot font, In 2x7dot, combination commands, @S and @D commands, are not available to be inputted in upper line and the lower line each. in case of above drawing, font type of character"B" is always as font type applied to "123" font. 2-5. Definition of print characters Output character ○○○○○○○○○○ ● ○● ● ● ● ○ ○○○○○○○○○○ ● ● ○● ●○ ○○○○○○○○○○● ● ○● ●○ ○○○○○○○○○○● ● ○● ● ● ● ○ ○○○○○○○○○○● ● ● ● ● ○● ●○ ○○○○○○○○○○● ● ○● ●○ ○○○○○○○○○○● ● ○● ● ● ● ○ PRINT DELAY CHARACTER CHARACTER SPACE 2-6. Composition of graphic Up to max. 124 Column(Width) of graphic can be set. - Moving sequence of graphic key DRAW<F1> ▶ MOVE<F1> ▶ DELETE<F1> - Composition of 16 Dots Graphic Up to Max.124 columns(in width) can be inputted. 15 LP7200+ INK JET PRINTER - Graphic composition of 7 Dots Up to Max.124 columns(in width) can be inputted. - Definition of Graphic space On occasion of mixed print of Graphic and Text, character space is as next. ex) Combination of 7 Dots Graphic and Text ex) Combination of 16 Dots Graphic and Text 16 LP7200+ INK JET PRINTER 2-7. Composition of the reduced font characters Font reduce print is a function which can print out the character by adjusting the character's height by printhead's angle. When printhead is vertical, it prints out as below. By adjusting printhead's angle, you could set font correctly. ● ● ● ● ● ● ● ●●●●● ● ● ● ● SINGLE PRINT FONT : 0 VERTICAL PRINTHEAD ● ○● ● ○○● ● ○○○● ● ○○○○● ● ● ● ● ○○○○○● ● ○○○○○○● ● ● ○○● ● ○○○○● ● ○○○○○○● ● ○○○○○○○○● ● ● ● ● ○○○○○○○○○○● ○○○○○○○○○○○○● 0 COLUMN DELAY 1 2 3 4 5 6 SINGLE PRINT FONT : 1 VERTICAL PRINTHEAD 0 COLUMN DELAY 2 4 6 8 SINGLE PRINT 10 FONT : 2 12 VERTICAL PRINTHEAD ● ● ● ○○○● ● ○○○○○○● ● ○○○○○○○○○● ● ○○○○○○○○○○○○● ● ● ● ● ○○○○○○○○○○○○○○○● ● ○○○○○○○○○○○○○○○○○○● ● 0 COLUMN DELAY 3 6 9 12 SINGLE PRINT 15 FONT : 3 18 VERTICAL PRINTHEAD * Notice for FONT REDUCE application - On an occasion of FONT REDUCE application a printing character may be loosen or may not be printed correctly. - When moving speed of an object is irregular, the loosen letters can be correct by applying speed encoder. - FONT REDUCE is revealed severely in height and width of character depending on moving Speed of objects and angle declination of printhead. So, first after setting the font reduction value, you'd better control the character directly regulating print speed and angle of the printhead. 17 LP7200+ INK JET PRINTER 2-8. Definition of printing direction 1) Right printing direction - Use when it prints on an object moving from left to right Output character ABC printhead moving direction of an object 2) Left printing direction - Use when it prints on an object moving from right to left Output character ABC moving direction of an object printhead 2-9. Definition of printing signal - Printing signal works by receiving a printing signal of the mechanical switch or the photo sensor which recognize an object to be printed . - Once it receives printing signal, all contents set by parameter should be printed and in the middle of printing, the repeated printing signal is neglected till all printing is over be neglected before print-out ends. - Printing example of Repeat Print <NO> (Applied to a packaging box or a single product) ● photo sensor printhead ABC123 ABC123 print of printing contents delay sensor off time printing 1 cycle sensor on time 18 moving direction of product conveyor LP7200+ INK JET PRINTER - Printing example of Repeat Print <YES> (Applied to serial products like films) ● ABC123 delay print 1 cycle ABC123 delay print ABC123 delay 2 cycle (print end) print 3 cycle sensor on time * If recognition of objects is finished while the last printing content is being printed, it ends after printing the contents out to the last. * As above, even the same printing contents are repeated three times, counter adds only once , that is, the number of times as which sensor recognized an object. 2-10. Composition of memory location Memory locations consist of 100 text memory locations which user can select and input and 50 graphic memory locations in which you can input the graphic of a user character or graphic logo. 1) Explanation of text memory location There are 100 memory locations and in one memory location, 1000 characters can be inputted and outputted. If input exceed the allowable limit of memory location for input, then, there would be an error message, TEXT MEMORY FULL. You could name 00-99 of memory locations and input them or read them on display. By using combination command, you can call another memory location to a memory memory location and combine them. 2) Explanation of graphic memory location There are 50 memory locations, at which can input user characters or logo and max 6200 dots of graphic data can be inputted in whole memory locations horizontally. One memory location can input max 16(H)or 7(H)X124(W) of graphic data. You could name 100-50 of memory locations and input them or read them on display. You can combine graphic data and print them. It is available to combine up to max 10. 19 LP7200+ INK JET PRINTER 3. PROGRAMMING 3-1. F1. MEMORY SET - Inputting, saving or modifying works of the desired contents to print are available. - Memory locations to which user can input data are total 100 and the max. 1000 characters (5X7 dot) can be inputted into 1 line. - Memory locations into which you can input graphic data are 50 and the graphic data has to be inputted on Graphic Mode. - User Memory location can be associated with others and they are saved and print out. - Working circumstance has to be set on equipment usage circumstance set (print set) prior to inputting contents for an out-put. - Composition of command ▶ F1 MEMORY SET After using F1 on Keyboard or moving arrow to F1, press Save button. Display composition of MEMORY SET >> MEMORY SET << 1. WRITE MEMORY 2. READ MEMORY 3. FILE DELETE - Description of function by command ▶ 1. WRITE MEMORY - When cursor locates at 1. Write Memory or number button 1 is pressed, you can enter WRITE MEMORY mode and pass to the display shown as below. - Range of User Memory location is from 00 to 99. - Below is when nozzle type is set to 1 x 5, 1 x 7, 1 x 16. >> WRITE MEMORY << L1 Memory address<F3>:0 CAPS KEY SHIFT_KEY F1:INS F2:DEL F4:P.H 1 LP7200+ INK JET PRINTER Text can be inputted by L1 cursor and the text which is inputted longer than screen moves to the left of the next line. Using ◀,▶, you can move cursor. If <F3>key is pressed, the cursor moves to memory address. You can set memory address that you want to set and save it. If <F3>key is pressed without saving it, you can modify the contents again.. - To revise contents, you could use F1.INS, F2.DEL, key. If you press the buttons of CAPS, SHIFT , a shadow figure is shown on display and you can input large, small or special letters. <SAVE> passes to PRINT IMAGE display after saving. - Below is when nozzle select is set to 2 x 5, 2 x 7. >> WRITE MEMORY << L1 L2 Memory address<F3>:0 CAPS_ KEY SHIFT_KEY F1:INS F2:DEL F4:P.H Text can be inputted along L1 or L2 cursor and the text which is inputted longer than display moves to the left of the left line, using ◀,▶, you can move cursor. When the button <F3> is pressed you can set Memory location at which you want to save into and save it. If<F3>key is pressed without saving it, you can modify the contents again. If you press the button of CAPS, SHIFT, a shadow figure is displayed on display and you can input large, small or special characters. <SAVE> pass to PRINT IMAGE display after saving. - Below is display of PRINT IMAGE >> PRINT IMAGE << ABCDE0123 - On PRINT IMAGE display it is possible to check out graphic image, as well. - Printing contents on set MEMORY LOCATION are printed even after you might return to main menu or connect again after turning the power off. 2 LP7200+ INK JET PRINTER - Operating a keypad in the middle of printing contents or photocell's detecting an object is possible. Only, on occasion of pressing the "SAVE" button to save inputted content, next printing contents are delayed till an input will be finished. - Parameters such as Print Speed, Print Delay, Dot Size etc. are printed out at the same time as an input. - The combination of printing contents You can call different memory location into set location and combine them. - Example 1) combination of printing contents Below is when nozzle select is set to 2 x 7. >> WRITE MEMORY << *@ : Refer to Combination command L1 ABC@002 L2 123@100 Memory address<F3>:0 CAPS_ KEY SHIFT_KEY F1:INS F2:DEL F4:P.H - Below is display of PRINT IMAGE >> PRINT IMAGE << ABCDEF 123 → Assumption of an input of DEF at @002 Assumption of an input of arrow(→) for @100 graphic data - In the middle of printing out data, if you want to printout the changed contents after changing data of @002 into GHI, call the No.1 out of F1.READ MEMORY and print out. - Example 2) combination of printing contents When Nozzle Select on F2 PRINT SET is set to 1X16 Printing contents A YY.MM.DD HH:mm COUNT B 3 LP7200+ INK JET PRINTER If you would like to input above, please input as below. When Nozzle Select is set to 1X16 >> WRITE L1 L2 A MEMORY << @T.@I.@M @H:@R@C * @ : Refer to combination command B Press F4 button for changing to 7dot. Memory address<F3>:0 CAPS_ KEY SHIFT_KEY F1:INS F2:DEL F4:P.H - Note> In case you input as above to combine the command used @ with two lines, you have to input @ in same vertical line with using F4 button when it is set to 2X7 Dot. On screen, @ should be located same position. If a counter input value is the number of 4 digits, "B" is printed out after the number of 4 digits are printed out. ▶ 2. READ MEMORY Composition of MEMORY SET display >> MEMORY SET << 1. WRITE MEMORY 2. READ MEMORY 3. FILE DELETE -By moving cursor to 2.READ MEMORY or pressing a number or pressing a number key2, you can enter READ MEMORY and a next display will be displayed. - By using READ MEMORY , you can call the data set on user memory location and a <SAVE> is pressed right after calling them, the called data on PRINT IMAGE are displayed and can be printed out directly. - Memory locations you could call are from 00 to 99 of text memory location. - If there are no data saved on the called memory location, EMPTY MEMORY message will be displayed. 4 LP7200+ INK JET PRINTER - Example) If you call 01 Location which ABC123 is inputted at. >> PRINT IMAGE << ABC123 ▶ 3. FILE DELETE <SAVE> FILE DELETE display. - FILE DELETE is used for deleting memory of the set MEMORY LOCATION. - For File Delete, you could erase 000-150 addresses of Memory location can be set and deleted. - Without using FILE DELETE , if new contents are inputted on the set location in MEMORY EDIT, the previous contents will be deleted automatically and new contents will be inputted. - Display of FILE DELETE >> FILE DELETE << FILE NUMBER : 000 --------------------[SAVE] 5 LP7200+ INK JET PRINTER 3-2. F2. PRINT SET -PRINT SET is used for changing parameters of printing contents and user can control status of contents when user call the inputted contents and print out them. - You should set all parameters on PRINT SET to fit a working condition before applying equipments on the place. - Saved parameters are applied to whole printing contents and if you revise them, the revised contents are applied to all printing contents. - For going back to main menu in the middle of setting up, you press ESC button and for saving press SAVE button. If you want to return to the very previous stage of menu display right after saving and then to main menu, press ESC once more. - Composition of command ▶ F2 PRINT SET Press SAVE button with F2 on keyboard or moving arrow to F2. Composition PRINT of PrintSET set >> PRINT SET << For entire movement of the screen to 1. 2. 3. 4. 5. DIRECTION PRINT DELAY PRINT SPEED DOT SIZE REPEAT PRINT ↓ 6. 7. 8. 9. 0. SPEED ENCODER NOZZLE TYPE FONT TYPE FONT REDUCE PASSWORD OPTION another one, press "▲" key ↓ indicates that there is a menu display below. - If above screen is shown, you could move to the set menu display with pressing <SAVE> button after moving arrow button or pressing related figure button. - Explanation of Command Function ★ Note : In modes of DIRECTION, PRINT DELAY and FONT REDUCE No.1 Printhead No.2 Printhead Both Printhead are saved in order to be able to be operated separately, and displays of these modes' are all set by 7 Nozzle type of PRINT SET. - Types of Direct movement key Regarding to Dot size, Print speed and Print delay, after revising the value of input with direct movement key and saving, the key moves to related screen of Function code 6 LP7200+ INK JET PRINTER and you could print out revised input contents. - Variation of display composition by Nozzle select Example 1) If nozzle select is set to one of 1x5, 1x7 and you enter DIRECTION mode, the following will be shown as below. >> DIRECTION << 1. RIGHT 2. LEFT 3. UPSIDE DOWN<R> 4. UPSIDE DOWN<L> [BOTH] [SAVE] P.H SELECT <F2> Example 2) If nozzle select is set to one of 2x5, 2x7 and you enter PRINT DELAY mode, the following will be shown as below. >> PRINT DELAY << F2 : BOTH → F2 : HEAD1 → F2 : HEAD2 DELAY COLUMN : 000 (0-9999) Whenever F2 is pressed, order of P.H is changed. [BOTH] [SAVE] P.H SELECT <F2> Example 3) If nozzle select is set to 1x16 and you enter Tilt mode, the following will be shown as below. >> FONT REDUCE << ▶ FONT < 0 > FONT < 1 > FONT < 2 > FONT < 3 > [BOTH] [SAVE] P.H SELECT <F2> 7 LP7200+ INK JET PRINTER - Explanation of print set by function ▶ 1. DIRECTION >> DIRECTION << 1. RIGHT 2. LEFT 3. UPSIDE DOWN<R> 4. UPSIDE DOWN<L> [BOTH] [SAVE] P.H SELECT <F2> Use ▲, ▼ for movement of up and down. - DIRECTION decides printing direction of printing contents. - Refer to 2-8. Definition of Printing direction. - If you use two printheads, you could print out different direction with No.1 and No.2 printhead. If you want to print out same direction with 2 printheads or use one 16dots printhead, you should set on P.H SELECT.<F2> - Depending on circumstance of printhead installation, direction could be printed out on the inversion. - UP SIDE DOWN can print out characters turned up side down. ▶ 2. PRINT DELAY >> PRINT DELAY << DELAY COLUMN : 000 (0-9999) [BOTH] [SAVE] P.H SELECT <F2> - Function of PRINT DELAY is for printing contents after delaying column as much as set values after recognizing of objects. - Range of input value of PRINT DELAY is from 0 to 9999 and if the value exceeds 9999, it does not be inputted. - Refer to 2-5. Definition of Printing Character 8 LP7200+ INK JET PRINTER ▶ 3. Print PRINTspeed SPEED >> PRINT SPEED << PRINT SPEED : 0000msec (0-60000) ------------------[SAVE] - PRINT SPEED controls moving speed of solenoid valve according to moving speed of objects. - Low number indicates fast speed and high number means slow speed. - Refer to 2-5. Definition of printing character. - An input value of PRINT SPEED is affected by DOT SIZE when data is print out and could get fast or slow. ▶ 4. DOT SIZE >> DOT SIZE << DOT SIZE : 060msec (0 ~ 200) -----------------[SAVE] - Dot size adjusts size of dot(amount of ink's spray) with adjusting open time of solenoid valve. - Low number indicates the open time of solenoid is short and high indicates the open time is long. - Range of input of dot size is 0~200 and if the range is over 200, an input is impossible. - Refer to 2-5. Definition of Printing character. <Note>As DOT SIZE has an effect on PRINT SPEED directly, higher value than regulation value causes the situation that PRINT SPEED get slow automatically. 9 LP7200+ INK JET PRINTER 10 LP7200+ INK JET PRINTER ▶ 5. REPEAT PRINT >> REPEAT PRINT << 1 : YES 2 : NO ------------------[SAVE] - Refer to 2-9. Definition of printing signal. - Function of Repeat print is for printing out contents continually by the set cycle while receiving printing signal. - If REPEAT PRINT is set to YES and Delay is set to 10, it accomplishes continuous printing works from starting time of printing signal to its end. - If REPEAT PRINT is set to NO, after it prints only once according to a printing signal, it waits till next printing signal. - Repeat print is used when you print out the same contents continually. - For Up counter, it counts only when printing signal is detected once even when REPEAT PRINT is operated. - Repeat print <Yes> printing ABC123 DELAY ABC123 DELAY ABC123 DELAY contents printing signal - Repeat print <No> printing ABC123 ABC123 DELAY ABC123 contents printing signal 11 LP7200+ INK JET PRINTER ▶ 6. SPEED ENCODER >> SPEED ENCODER << 1 : ENCODER USE 2 : ENCODER UNUSE ----------------[SAVE] - SPEED ENCODER is used when object's moving speed is irregular or it prints after receiving outer pulse signal. - At the same time it receives printing signal (outer sensor), it also starts to receive encoder's pulse signal. By the set parameter it prints out. - When Encoder use is set to YES, if encoder does not work after receiving a printing signal, then, encoder operates to be waiting status for printing till 1 cycle of 1printing is finished. (if you turn the power off it can not remember the printing signal received before, so some revision is possible). - Example of ENCODER USE <YES> ● ● ● ● ● ● ● ●●●●● ● ● ○○○○○○● ● ● ●● ● ● ● ● ●●● ●●● ● ●●●● ● ● ● ● ● ●● ● ● ●●●●● ● ● ●●●● 1 column print per 1 purse delay 1 cycle - If SPEED ENCODER use is set to <NO>, it prints out evenly by a set print speed value. 12 LP7200+ INK JET PRINTER ▶ 7. NOZZLE TYPE >> NOZZLE TYPE << 1. 1 X 5 2. 2 X 5 3. 1 X 7 4. 2 X 7 5. 1 X 16 -----------------[SAVE] - Refer to 2. Composition of printing fonts - The Function of Nozzle type is for composition of printhead and basic fonts to be printed before using printer. - If printing contents are inputted by setting of Nozzle type, you can print the set basic fonts and you also could print out by combining other fonts except basic font using combination command. - 1 x 5 : Using one 5 dot printhead. Output 5 x 5 dots - 2 x 5 : Using two 5 dot printheads. Output 2 lines of 5 x 5 dots - 1 x 7 : Using one 7 dot printhead. Output 5 x 7 dots - 2 x 7 : Using two 7 dot printheads. Output 2 lines of 5 x 7 dots - 1 x 16 : Using one 16 dot printhead. Output 10 x 16 dots ▶ 8. FONT TYPE >> FONT TYPE << SINGLE <S> DOUBLE <D> LIGHT <L> ----------------[BOTH] [SAVE] P.H SELECT <F2> - Refer to 2-2. Composition of applied fonts - Font type sets basic fonts to be used mainly before using a printer. - Set of Font type is applied to every printable fonts. - Font type can be combined with one another and inputted with using <@S,@D,@L>. 13 LP7200+ INK JET PRINTER ▶ 9. FONT REDUCE >> FONT REDUCE << FONT <0> FONT <1> FONT <2> FONT <3> FONT <4> FONT <5> [HEAD1] [SAVE] P.H SELECT <F2> - Refer to 2-7 Composition of FONT REDUCE. - Font adjusts height of printing character according to angle of printhead. - Font 0 : No reduction applied. - Font 1 : small angle ABC123 ABC123 - Font 2 : medium angle ABC123 - Font 3 : big angle -1 ABC123 - Font 4 : big angle -2 ABC123 - Font 5 : big angle -3 ABC123 ▶ 0. PASSWORD OPTION >> PASS OPTION << 1. NO 2. YES [HEAD1] P.H SELECT [SAVE] <F2> - PASSWORD OPTION function is for preventing others than the designated equipment managers from operating equipment. - when you use this function, if you turn the power on again after , turning it off, a password input display will be shown and it prints out the contents inputted before turning it off. - Password is 4002. - If password is inputted wrong, !!PASSWORD ERROR!! Message is represented. - If you set this function set to 1.No, password input display would disappear and pass to Main menu directly. 14 LP7200+ INK JET PRINTER 3-3. COUNTER SET - It counts with receiving printing signal of Counter set, it can count number of objects to be printed and then print out them. - COUNTER SET can be combined with printing contents with shorten key and be printed. - Even after turning the power off, it counts next number remembering the number counted. - You can check the present number of at Print set menu at any time. - Contents of F3. COUNTER SET are modified, present printing contents are printed into the revised. - Counter displays a present Counter value on print image display. - Composition of command ▶ F3 COUNTER SET After using F3 button on keyboard or moving arrow to F3, press SAVE button. Composition of COUNTER SET * Refer to 3-2. Explanation of function of PRINT SET command. >> COUNTER SET << START : 0 STOP : 000000000 REPEAT COUNT : 000 SKIP[0] : YES/NO OPT : BASE/ODD/EVEN COUNTER APPLY <C> [BOTH] [SAVE] * On occasion of not using counter, press key on keyboard.(Then, Counter is not represented on print image display.) * On occasion of operating the RESET of the counter, put the cursor on START and press "SAVE" key, and counter starts to count again by the value set on the START. - START : Inputs the number which will start counting. The unit is up to 9 - STOP : You could input the last number of counter If it counts to the set number, It goes back to the set number on START and counts again. - REPEAT COUNT(Function of BATCH Counter) : Input number of repetitive counter. If 3 is inputted into repetitive counter, the counter adds one more time after counting the same number while it recognizes printing signal three times. A assumption of an input to START 1, STOP 5 repeat 3. 1→1→1→2→2→2→3→3→3→4→4→4→5 →5→5 15 LP7200+ INK JET PRINTER - SKIP[0] : If four digits are printed out, 1 - 2 - 3 without "0" are printed out instead of 0001 - 0002 - 0003 (in case of "Yes" set-up). - OPT : BASE/ODD/EVEN Up counter setup BASE : general up-counter mode ODD : Odd number up-counter mode EVEN : Even number up-counter mode * In case of ADD or EVEN set-up, you should set a number for START of counter in accordance with ODD or EVEN in advance. For example, in case that START is set into 00, if you try to set up ODD, a error message - START DATA ERROR - will be shown on display. - COUNTER APPLY <C> : For an output after your inputting counter, use @C. - Example of printing of counter Assumption of input to START 1, STOP 20 . 1→2→3→ 4→ 5→ 6→ 7 →8→ 9 →10→ 11→ 12→ 13 →14→ 15→ 16→17 →18 →19→ 20 - Check for the volume of a present counter. The present counted volume is shown on the bottom of the PRINT IMAGE display. >> PRINT IMAGE << ABC001 * Display status of 1x7, 1x16 (Nozzle select) L1 : 0021 As above, L1 : 0021 on the bottom line indicates the present counted number and increases whenever a sensor detects a object. If you're on other working menu out of PRINT IMAGE display, You can check the number counted so far by calling memory address which is being used at present from F1.READ MEMORY. 16 LP7200+ INK JET PRINTER - Initialization of the volume of counter (when the counter is not in use). As below, if the COUNTER EXIT is set, the volume of COUNTER is not shown on print image display >> COUNTER SET << START : 0 STOP : 000000000 REPEAT COUNT : 000 SKIP[0] : YES/NO OPT : BASE/ODD/EVEN COUNTER APPLY <C> [BOTH] [SAVE] !! COUNTER EXIT !! Press key Return counter set menu Press ESC Key to return main menu - Reset of the volume of counter number. On above display, after putting the cursor at START, press "SAVE" key, and a counter resets. - Reset of the COUNTER starts counting again from a initial value of counter set in START. 3-4 CLOCK SET - Clock set is a set-up mode for printing out present time, expiry data and shift code. - Present time continue to be processed by BATTERY BACK-UP, even after the power is turned off. - Using combination shorten key, clock set could be printed out. - Expiry data is processed the same as present time from date which is set. - Composition of command. ▶ F4. CLOCK SET After pressing F4 button on keyboard or moving arrow to F4, press SAVE button. Composition of Clock set >> CLOCK SET << 1 : REAL TIME CLOCK 2 : EXPIRY DATE 3 : SHIFT TIME 17 LP7200+ INK JET PRINTER ▶ 1. REAL TIME CLOCK >> REAL TIME << 1. YEAR < T > : 01 2. MONTH < I > : 03 3. DAY < M > : 14 4. HOUR < H > : 10 5. MINUTE < R > : 45 ------------------[SAVE] 2001-03-14 10 : 45 : 15 [SAVE] [ESC] Return menu Display of time inputted - Input real time into REAL TIME CLOCK - After inputting the time that you want by moving cursor up and down, save it. - You can combine it with other printing contents and print them with using shorten key of the inside of < >. - To print out present time Example) To print out year, month, day, hour and minute, please input on WRITE MEMORY as below. >> WRITE MEMORY << L1 20@T.@I.@M @H:@R Example) To print out year 2000, Memory address<F3>:0 CAPS_KEY SHIFT_KEY F1:INS F2:DEL F3:P.H please input 20 before @T Status of PRINT IMAGE after pressing [SAVE] button shows present time into which is converted automatically >> PRINT 2000.08.25 IMAGE << 17:50 - Printing contents are the same as PRINT IMAGE. 18 LP7200+ INK JET PRINTER ▶ 2. EXPIRY DATE >> EXPIRY DATE << 1. YEAR < E> : 00 2. MONTH < X > : 00 3. DAY < P > : 00 -----------------[SAVE] - Input expiry date of set product. - BY using shorten key in <>, you could combine it with other printing contents and print them out. - EXPIRY DATE is processed the same as present time from date which is set. - EXPIRY DATE should be set into future time not into present time. - To print EXPIRY DATE out Example) To print out BEST BEFORE, YEAR, MONTH and DAY, you should input them on WRITE MEMORY shown as below. >> WRITE MEMORY << Example) To print out year 2000, L1 BEST BEFORE 20@E.@X.@P please input 20 before @T Memory address<F3>:0 CAPS_KEY SHIFT_KEY F1:INS F2:DEL F3:P.H Status of PRINT IMAGE after pressing [SAVE] button shows the Expiry date into which is converted automatically as blow. >> PRINT IMAGE << BEST BEFORE 2001.08.25 - Printing contents are same as PRINT IMAGE. 19 LP7200+ INK JET PRINTER ▶ SHIFT CYCLE >> SHIFT CYCLE << START TIME : <00:00> CYCLE TIME : 0 SET : ALPHA /NUM/NAME SHIFT CYCLE APPLY <A> --------------------[SAVE] By using ◀, ▶, cursor, move to right and left. - SHIFT CYCLE is for printing working shift into Alphanumeric information after changing as the set cycle. - For START TIME, you input the start time of shift cycle. - For CYCLE TIME, you set working cycle (within 24 hours). - For SET you can set cycle period with alphanumeric information. Using shorten key(A), you could combine it with other printing contents and print out. - Example) If it is set as START TIME 24:00, SHIFT CYCLE 4, SET ALPHA, time 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A ---------AB--------BC---------CD--------DE--------EF--------F - If number is set on SET, working cycle is changed in order of 1 ,2 ,3, 4, 5 ,and6. - SHIFT CYCLE APPLY Example) To print out present time and working shift, shift time can be printed after being inputted on WRITE MEMORY as below. >> WRITE MEMORY << L1 @H:@R @A Memory address<F3>:0 CAPS_KEY SHIFT_KEY F1:INS F2:DEL F4:P.H - Status of PRINT IMAGE after pressing [SAVE] button shows that the inputted shift is converted automatically fitting to present time and displayed. 20 LP7200+ INK JET PRINTER >> PRINT IMAGE << 17.30 D - Printing contents are same as PRINT IMAGE. - Setting and inputting as NAME on SET. - Put the cursor on NAME and press save, and it moves to the next display. - Printout for shift cycle name >> CYCLE NAME << * If you want to return to main menu after NAME-1 : NAME-2 : NAME-3 : NAME-4 : ------------------[SAVE] saving, press SAVE after moving cursor to START TIME or CYCLE TIME. - Inputting the set characters of working shift CYCLE NAME is available for input 4 kinds of names. Each name is available up to 10 characters for an input. If CYCLE NAME is inputted, movement of working shift is available for marking example) NAME-1 : ABC NAME-2 : DEF NAME-3 : GHI NAME-4 : 123 CYCLE TIME : If the cycle time is inputted with 6 hours printing order is same as the next. ABC DEF GHI 123 (changed by cycle of 6 hours respectively) 21 LP7200+ INK JET PRINTER 3-5 INITIAL SET - On INITIAL SET, you could input and revise the graphic data as a user's word and there are two functions like as Fuzzy of printhead and INTERFACE function. - Composition of command ▶ F5. INITIAL SET After pressing F5 button on keyboard or moving arrow to F5, press SAVE button. Composition of INITIAL SET display >> 1 2 3 4 5 6 : : : : : : INITIAL SET << GRAPHIC EDIT GRAPHIC READ HEAD PURGE INITIALIZE NETWORK SELECT "O" SELECT ▶ 1. GRAPHIC EDIT After pressing 1 on the keypad or putting cursor on 1, press [SAVE] and it moves to display which is available for GRAPHIC DRAW. >> GRAPHIC EDIT << DOT DRAW (F1) MEMORY ADDRESS(F3): 00 F2 : L1 [SAVE] - Use of Graphic key movement into up, down, left, right 1 3 7 9 diagonal movement - Whenever you press F1 button, it is changed to DOT DRAW → MOVE→ DELETE. - By using shorten key @100 - @150, graphic could combine with other printing contents and print them out. 22 LP7200+ INK JET PRINTER - If graphic data do not correspond with nozzle type of PRINT SET, the graphic data can't be printed out. - You could input graphic data with setting Memory location after pressing button F3. - The range of graphic memory location is 00-50 and when you call it using combination command, you should input number from 100 to 150. - Printing out of the inputted graphic data. Example) If you want to print after saving the graphics of ★ at 100 location, ○ at 101 location, ♠ at 102 location, you can print it out after inputting on WRITE MEMORY. >> WRITE MEMORY << L1@100 @101 @102 ABC Memory address<F3>:0 CAPS_KEY SHIFT_KEY F1:INS F2:DEL F4:P.H - Status of PRINT IMAGE after pressing [SAVE] button is shown as below >> PRINT IMAGE << ★○♠ABC * space of a graphic data - Only graphic data drawn on display are included in the out-put contents. - In order to connect a graphic with another, you can print them after combining and connecting the different graphic memory addresses. 23 LP7200+ INK JET PRINTER ▶ 2. GRAPHIC READ - If you press SAVE key after pressing No.2 key or moving arrow to No.2, a cursor moves to the display which is able to do GRAPHIC READ. - GRAPHIC READ can be inputted after checking or modifying the inputted graphic data. - How to modify graphic data is the same as GRAPHIC EDIT. >> GRAPHIC READ << DOT DRAW (F1) MEMORY ADDRESS (F3) : 00 F2 : L1 [SAVE] - If you revise and [SAVE] graphic data after reading them previous data is deleted automatically. ▶ 3. HEAD PURGE - After pressing number 3 button or moving arrow to No.3 button, press SAVE button, and you could input PURGE as below. - Printhead purge is for cleaning blocked nozzle or printhead. - If you select printhead purge, all nozzle sprays with regular spot 100 times. - Purge can be used by direct movement key on keyboard. - PURGE is processed on status of present display and another key movement is available after finishing 100 times of spray. >> PURGE OPTION << 1. NO 2. YES -------------------[SAVE] 24 LP7200+ INK JET PRINTER ▶ 4. INITIALIZE - After pressing No.4 button or moving an arrow to that number press SAVE, and the cursor will enter INITIALIZE mode. - When you use INITIALIZE mode, the whole inputted contents at Ram memory up to now are erased and return to initialization condition. - It is applicable to reinstall in other circumstance or in case of a change of using printhead type. * Note : If you use INITIALIZE mode, he whole memory will be erased. Please be careful. - INITIALIZE display >> INITIALIZE PASSWORD : << 0 --------------------[SAVE] - Password is 4002 and if a password is not correct it does not operate. - If you input the password correctly and press SAVE button, next display is shown up and the whole inputted contents would be erased and then return to main menu display after Initializing. >> INITIALIZE COMPLETE! 1 2 3 4 5 6 ▶ 5. NETWORK SELECT >> NETWORK SELECT << SELECT ID : 1 --------------------[SAVE] 25 INITIAL SET : : : : : : << GRAPHIC EDIT GRAPHIC READ HEAD PURGE INITIALIZE NETWORK SELECT "O" SELECT LP7200+ INK JET PRINTER - The NETWORK SELECT is a function for setting a ID No. of each controller in order to transmit data connecting the max. 15 of LP7200+ controllers in case of using a function of 8 .Multi communication - For SELECT ID choose one of 1,2,3,4,5,6,7,8,9,A,B,C,D,E andF. - Master controller should be set into 1, slave controller is to 2-F . ▶ 6. "O" SELECT >> "O" SELECT << select using ◀, ▶ key SELECT TYPE : O/Θ -------------------[SAVE] - This is function for preventing mistaking number "0" from English character "0". - If you set "0" select into Yes, number "0" is printed out as an 0 with an oblique line. ▶ 7. LANGUAGE SELECT >> LANGUAGE << 1. ENGLISH 2. KOREAN -------------------[SAVE] - After pressing a no.7 key or moving by arrow keys, pressing the SAVE key can enter the next LANGUAGE mode. - A choice of LANGUAGE is available adjusting to the use conditions and the displayed letter is displayed as a selected language. 26 LP7200+ INK JET PRINTER ▶ 8. MULTI COMMUNICATION >> MULTI COMM. << 1. NO 2. YES -------------------[SAVE] - After pressing a no.8 key or moving by arrow keys, pressing the SAVE key can enter the next LANGUAGE mode. - Initial setting for a function of multi communication is set into 1.NO, in order to use it you should SAVE after choosing 2. YES. - A function of multi communication makes it possible to connect the max. 14 of LP7200+ slave controller into one master controller. - Only using a keypad of a master controller you can input marking contents, call or edit yourself by the next slave controller which is in multi connected. - A function of multi communication is available only when communication setting of control board is set into RS-485 (Setting into RS-232 is not available and refer to INTERFACE for setting) - If it is set into RS-232 , 1 to 1 communication only is possible. - Use of a function of MULTI COMMUNICATION EX) In case of inputting ABS0123 at a number of 10 memory address of the 3rd slave controller, you can use the fuction as follows. >> WRITE MEMORY << L1 ABC0123 Memory address<F3>: 0 CAPS_ KEY SHIFT_KEY F1:INS F2:DEL ▼ 27 LP7200+ INK JET PRINTER >> WRITE MEMORY << L1 ABC0123 Memory address<F3>: 10 CAPS_ KEY SHIFT_KEY F1:INS F2:DEL ▼ [SAVE] >> RECEIVE RECEIVE ID << ID : 3 ERROR ▶ -------------------[SAVE] ▼ [SAVE] !!! TRANS OK !!! ▼ >> MEMORY SET << 1. WRITE MEMORY 2. READ MEMORY 3. FILE DELETE 28 !!! COMM ERROR !!! LP7200+ INK JET PRINTER 3-6 DIRECT MOVEMENT KEY - Direct movement key can be used for prompt initial installation and revision fitting to working circumstances. - Direct movement keys consist of PRINT SPEED, DOT SIZE, PRINT DELAY and PRINTHEAD PURGE right after modifications are done, printing contents are modified. - Use of direct movement key can transfer into a display that a direct movement key sets if you press a key within function codes or an initial display status. - If you modify the content by using a direct movement key on PRINT IMAGE display or press ESC key, modified content is saved and return to PRINT IMAGE display automatically. - Use of the direct movement key DOT SIZE >> Use of the direct movement key of DOT SIZE DOT SIZE << DOT SIZE : 060msec -------------------[SAVE] PRINT SPEED >> Use of the direct movement key of PRINT SPEED PRINT SPEED << PRINT SPEED : 10000msec -------------------[SAVE] 29 LP7200+ INK JET PRINTER PRINT DELAY Use of the direct movement key of PRINT DELAY >> PRINT DELAY << DELAY COLUMN : 000 P.H SELECT <F2> ------------------[HEAD1] PURGE [SAVE] Use of the direct movement key of PRINT HEAD PURGE >> PRINTHEAD PURGE << ------------------- 30 LP7200+ INK JET PRINTER 4. USE OF COMBINATION COMMAND 4-1. Definition of combination command - Combination command could change a basic set value of font or combine memory location each other in the middle of inputting data. And it could also composite Data format simply with inserting present time into printing contents. - Types of combination commands @ 000 - 099 : Memory combination command (It could print out with combining Text memory) @ 100 - 150 : Graphic combination order (It could print out with combining Graphic memory) @C : Set an input of Up counter @T : Set an input of YY(Year) @I : Set an input of MM(Month) @M : Set an input of DD(Date) @H : Set an input of HH(Hour) @R : Set an input of mm(minute) @N : Set ss(second) @E : Set an expiry of YY(Year) @X : Set an expiry of MM(Month) @P : Set an expiry of DD(Date) @A : Set an input of shift mark of SHIFT CYCLE @S : Single print command @D : Double print command @L : Light print command @W : Set month name (A to L) - Combination command consists of one @shorten key and you could input desiring DATA with inserting above shorten key on Write Memory. EX1. Example of combination command Printing Contents: ABC 123 456 DEF ABC<7dot>123 <16dot>DEF Explanation:<16dot> <7dot>456 31 LP7200+ INK JET PRINTER Nozzle Type : 1 x 16 - Inputting on WRITE MEMORY >> WRITE MEMORY << L1 L2 123 456 ABC DEF * Press F4 button for changing 16dot to 7dot. Memory address<F3>:0 CAPS_KEY SHIFT_EKY F1:INS F2:DEL F4:P.H EX2. Example of combination command Contents to be printed : 2000.08.12 14:50 A 001 (year.month.day, hour:minute, working shift counter) Explanation : When Nozzle type is set into 1X7, present time, 00(year) 08(month) 12(day) 14(hour) 50(minute), working shift into A and counter into 001, input as below. - Inputting on WRITE MEMORY. >> WRITE MEMORY << L1 20@T.@I.@M @H:@R @A @C Memory address<F3>:0 CAPS_KEY SHIFT_EKY F1:INS F2:DEL F4:P.H - Notice on an occasion of a combination of memory address. Memory address is available to combine up to max 10 memory address. The memory address which has already been combined can't be used in combining it over 2 times. EX3. Example of combination command (@W month name) - It is available when you want to print an indication of the month of marking contents into English. When @W is used, an indication of the month is transformed into English and printed it out as below shown in the table. month transformed month 01 02 03 04 05 06 07 08 09 10 11 12 A B C D E F G H I J K L 32 Additional function 1) When you want to check the counter no. at screen without printing counter no. <How to use> 1) At F3. COUNTER SET, set the START, STOP values and press <SAVE> key. 2) At F1. MEMORY, press 1.WRITE MEMORY and then input @C. 3) Press <F3> key and input 99 (memory location you want) and press <SAVE> key. - Check of the current counter no. PRINT IMAGE screen will display as below. >> PRINT IMAGE << ABC001 L1 : 0021 As above, L1 : 0021 of screen means the current counter no. and it is increased whenever sensing a product. 2) How to reset simply In the case of not using the machine for a long time, In the case of not moving a screen on controller, In the case of a sensor is not sensed. *Note: If you use this function, whole memory you saved will be erased. Please be careful to use. <How to use> Switch Power to ON pressing <ESC> key and then put off <ESC> key after a while and setting values will be erased.