Uploaded by 吴程万

RRUS 02 Guidelines

advertisement
(R)RUS 02
guidelines
By Yap CK 2012-08-02
Product
› GSM, WCDMA & LTE
› Up 40 MHz IBW
› Up to 8 carriers GSM
› Up to 4 carriers WCDMA or LTE
› Up to 1 x 100 W
› 2.5 Gbit/s CPRI
› 55 years MTBF
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 2
RUS 02 AND CABINET
COMPATIBILITY
› RUS 02 provide higher capacity, output power and
larger IBW
› Possible need for power and climate systems upgrade
for large configurations in installed base
› New cabinets will have full RUS 02 capability
› Site power and battery backup systems upgraded to
support new radio hardware
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 3
PLANNED FREQUENCIES
AND PRODUCTS
RUS 02
single TX RU
RRUS 02
single TX RRU
B0 - 900P
RUS 02 B0
RRUS 02 B0
NA
B1 – 2100
RUS 02 B1
NA
RRUS 12 B1
B2 – 1900
RUS 02 B2
NA
RRUS 12 B2
B3 – 1800
RUS 02 B3
NA
RRUS 12 B3
B4 – 17/2100
RUS 02 B4
NA
RRUS 12 B4
B5 – 850
RUS 02 B5
NA
RRUS 12 B5
B7 – 2600
RUS 02 B7
NA
RRUS 12 B7
B8 – 900E
RUS 02 B8
NA
RRUS 12 B8
B12 – 700(12)
NA
NA
RRUS 12 B12
B13 – 700(13)
RUS 02 B13
NA
RRUS 12 B13
B14 – 700(14)
NA
NA
RRUS 12 B14
B24 – 1600
NA
NA
RRUS 12 B24
Frequency Band
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 4
RRUS 12
dual TX RRU
CAPABILITIES
OUTPUT POWER FOR RUS 02 & RRUS 02
Macro
Output power
Main Remote
Output power
RUS 02 B0
1 x 100 W
RRUS 02 B0
1 x 100 W
RUS 02 B1
1 x 100 W
RUS 02 B2
1 x 80 W
RUS 02 B3
1 x 80 W
RUS 02 B4
1 x 100 W
RUS 02 B5
1 x 100 W
RUS 02 B7
1 x 60 W
RUS 02 B8
1 x 100 W
RUS 02 B12
NA
RUS 02 B13
1 x 100 W
RUS 02 B14
NA
RUS 02 B24
NA
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 5
CAPABILITIES
IBW FOR RUS 02
Macro
IBW
RUS 02 B0
25 MHz
RUS 02 B1
40 MHz
RUS 02 B2
40 MHz
RUS 02 B3
40 MHz
RUS 02 B4
35 MHz
RUS 02 B5
25 MHz
RUS 02 B7
25 MHz
RUS 02 B8
35 MHz
RUS 02 B12
NA
RUS 02 B13
10 MHz
RUS 02 B14
NA
RUS 02 B24
NA
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 6
RRUS 02 B0
IBW
Width of band
25 MHz
25 MHz
CAPABILITIES
CHARACTERISTICS PER PRODUCT
Frequency Band
Product
Output power
GSM Output power
with IPM
IBW
B0 - 900P
RUS 02 B0
100 W
160 W
25 MHz
B0 - 900P
RRUS 02 B0
100 W
160 W
25 MHz
B3 – 1800
RUS 02 B3
80 W
160 W
40 MHz
B3 – 1800
RRUS 12 B3
2 x 60 W
160 W
40 MHz
B8 – 900E
RUS 02 B8
100 W
160 W
35 MHz
B8 – 900E
RRUS 12 B8
2 x 60 W
160 W
35 MHz
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 7
(R)RUS 02 BASIC SW
REQUIREMENT
– BSS SW: G10B + ECA2 or later
– BTS SW: G12A_1 (B1307R066H) or later
ECA2 和BTS G12A_1已获移动入网许可
– OMT SW: OMT R45M or later
– IPM must be use for integration
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 8
POWER EFFICIENCY WITH
RUS 02
GSM 3x8, 900 MHz, RBS 6201
3 x RUS 02
6 x RUS 01
Power consumption with RUS 02
–30%
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 9
POWER EFFICIENCY WITH
RUS 02
EXAMPLE 1:
GSM ON 900 MHZ
Macro base station, 8 GSM carriers
> 20 MHz
X XX X
XX X X
freq
2 * RUS 01
(4 + 4 carriers)
< 35 MHz
X XX X
XX X X
freq
1* RUS 02
(8 carriers)
CAPABILITIES:
SAVINGS:
IBW
Output power
Capacity (carriers)
Installed hardware
Space
Power consumption
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 10
Mixed Hw of RUS02 and
RUS01
› RUS02和RUS01混合配置(RBS6201v2机柜)
– V2机柜最大支持12个RUS01;在增加RUS02作任意混合配置时如
果RU数量不超过9,则无需作任何改动。如果超过9个RU,则需要
升级机柜(9RU可支持的载波数已经达到60TRX,应能满足绝大部
分场景需求)。
› RUS02和RUS01混合配置(RBS6201v3机柜)
– 无限制
› RBS6201v2升级至RBS6201v3机柜解决方案
– 订购电源升级件
– SUP 6201 -48VDC upgrade kit, NTM 101 2389/1.
– SUP 6201 24VDC upgrade kit, NTM 101 2389/2.
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 11
RUS 02 Configuration
– 3*8(RBB 12_1A)
– 2 RUS02s could not share one
DUG, this configuration need 3
DUG20s and two subracks.
– In live network, when expansion
and replacement from RUS01 to
RUS02, the RBS6201 cabinet need
upgrade from V2 to V3.
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 12
RUS 02 Configuration
– 3*12,RUS01+RUS02(RBB 22_2B)
– One RUS01 and one RUS02
connected to one DUG20
– In live network, when expansion
and replacement from RUS01 to
RUS02, the RBS6201 cabinet need
upgrade from V2 to V3.
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 13
RRUS 02 新光纤接口
› RRUS 02 光纤借口升级至enhanced-LC借口(FullAXS)
– RRUS 02 光纤和适配器
› 用于RRUS 的光纤(暂时)
› 产品号:PRM 253 1633/100M
– 额外的光纤适配器配对处理普通LC接头适合普通LC接头光纤
› 增强使用普通LC接头光纤施工时的灵活性
› 产品号: SDF 107 236/001
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 14
RRUS 02 光纤接口适配器安
装说明
RRUS 02 光纤接口适配器 No. : SDF 107 236/001
› 打开密封套。
› 拉出垫圈。
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 15
RRUS 02 光纤接口适配器安
装说明
› 把光纤穿过密封套,穿入管中打开密封套。
密封套支持直径4.5至9 mm光纤
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 16
RRUS 02 光纤接口适配器安
装说明
› 把垫圈套入光纤并推入管中。
› 重新装好密封圈。
暂时不要上紧!
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 17
RRUS 02 光纤接口适配器安
装说明
› 把光纤接头(LC)插入RRU光模块。
RRU
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 18
RRUS 02 光纤接口适配器安
装说明
› 把管和罩推入RRUS接口。
拉住光纤避免弯曲
RRU
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 19
RRUS 02 光纤接口适配器安
装说明
› 拧紧接口罩
RRU
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 20
RRUS 02 光纤接口适配器安
装说明
› 拧紧密封圈。
在拧紧密封圈前小心的把光纤
推 入几毫米
RRU
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 21
RRU
RRUS 02 光纤走线规范
OK
NOT OK
扎带
扎带
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 22
RRUS 02光纤安装/拆卸指引
安装
拆卸
RRU
RRU
2
2
3
1
注意!
一定要先松开
密封圈再开密封罩
3
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 23
1
不能用力拉扯光纤
(R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 24
Download