(R)RUS 02 guidelines By Yap CK 2012-08-02 Product › GSM, WCDMA & LTE › Up 40 MHz IBW › Up to 8 carriers GSM › Up to 4 carriers WCDMA or LTE › Up to 1 x 100 W › 2.5 Gbit/s CPRI › 55 years MTBF (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 2 RUS 02 AND CABINET COMPATIBILITY › RUS 02 provide higher capacity, output power and larger IBW › Possible need for power and climate systems upgrade for large configurations in installed base › New cabinets will have full RUS 02 capability › Site power and battery backup systems upgraded to support new radio hardware (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 3 PLANNED FREQUENCIES AND PRODUCTS RUS 02 single TX RU RRUS 02 single TX RRU B0 - 900P RUS 02 B0 RRUS 02 B0 NA B1 – 2100 RUS 02 B1 NA RRUS 12 B1 B2 – 1900 RUS 02 B2 NA RRUS 12 B2 B3 – 1800 RUS 02 B3 NA RRUS 12 B3 B4 – 17/2100 RUS 02 B4 NA RRUS 12 B4 B5 – 850 RUS 02 B5 NA RRUS 12 B5 B7 – 2600 RUS 02 B7 NA RRUS 12 B7 B8 – 900E RUS 02 B8 NA RRUS 12 B8 B12 – 700(12) NA NA RRUS 12 B12 B13 – 700(13) RUS 02 B13 NA RRUS 12 B13 B14 – 700(14) NA NA RRUS 12 B14 B24 – 1600 NA NA RRUS 12 B24 Frequency Band (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 4 RRUS 12 dual TX RRU CAPABILITIES OUTPUT POWER FOR RUS 02 & RRUS 02 Macro Output power Main Remote Output power RUS 02 B0 1 x 100 W RRUS 02 B0 1 x 100 W RUS 02 B1 1 x 100 W RUS 02 B2 1 x 80 W RUS 02 B3 1 x 80 W RUS 02 B4 1 x 100 W RUS 02 B5 1 x 100 W RUS 02 B7 1 x 60 W RUS 02 B8 1 x 100 W RUS 02 B12 NA RUS 02 B13 1 x 100 W RUS 02 B14 NA RUS 02 B24 NA (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 5 CAPABILITIES IBW FOR RUS 02 Macro IBW RUS 02 B0 25 MHz RUS 02 B1 40 MHz RUS 02 B2 40 MHz RUS 02 B3 40 MHz RUS 02 B4 35 MHz RUS 02 B5 25 MHz RUS 02 B7 25 MHz RUS 02 B8 35 MHz RUS 02 B12 NA RUS 02 B13 10 MHz RUS 02 B14 NA RUS 02 B24 NA (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 6 RRUS 02 B0 IBW Width of band 25 MHz 25 MHz CAPABILITIES CHARACTERISTICS PER PRODUCT Frequency Band Product Output power GSM Output power with IPM IBW B0 - 900P RUS 02 B0 100 W 160 W 25 MHz B0 - 900P RRUS 02 B0 100 W 160 W 25 MHz B3 – 1800 RUS 02 B3 80 W 160 W 40 MHz B3 – 1800 RRUS 12 B3 2 x 60 W 160 W 40 MHz B8 – 900E RUS 02 B8 100 W 160 W 35 MHz B8 – 900E RRUS 12 B8 2 x 60 W 160 W 35 MHz (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 7 (R)RUS 02 BASIC SW REQUIREMENT – BSS SW: G10B + ECA2 or later – BTS SW: G12A_1 (B1307R066H) or later ECA2 和BTS G12A_1已获移动入网许可 – OMT SW: OMT R45M or later – IPM must be use for integration (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 8 POWER EFFICIENCY WITH RUS 02 GSM 3x8, 900 MHz, RBS 6201 3 x RUS 02 6 x RUS 01 Power consumption with RUS 02 –30% (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 9 POWER EFFICIENCY WITH RUS 02 EXAMPLE 1: GSM ON 900 MHZ Macro base station, 8 GSM carriers > 20 MHz X XX X XX X X freq 2 * RUS 01 (4 + 4 carriers) < 35 MHz X XX X XX X X freq 1* RUS 02 (8 carriers) CAPABILITIES: SAVINGS: IBW Output power Capacity (carriers) Installed hardware Space Power consumption (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 10 Mixed Hw of RUS02 and RUS01 › RUS02和RUS01混合配置(RBS6201v2机柜) – V2机柜最大支持12个RUS01;在增加RUS02作任意混合配置时如 果RU数量不超过9,则无需作任何改动。如果超过9个RU,则需要 升级机柜(9RU可支持的载波数已经达到60TRX,应能满足绝大部 分场景需求)。 › RUS02和RUS01混合配置(RBS6201v3机柜) – 无限制 › RBS6201v2升级至RBS6201v3机柜解决方案 – 订购电源升级件 – SUP 6201 -48VDC upgrade kit, NTM 101 2389/1. – SUP 6201 24VDC upgrade kit, NTM 101 2389/2. (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 11 RUS 02 Configuration – 3*8(RBB 12_1A) – 2 RUS02s could not share one DUG, this configuration need 3 DUG20s and two subracks. – In live network, when expansion and replacement from RUS01 to RUS02, the RBS6201 cabinet need upgrade from V2 to V3. (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 12 RUS 02 Configuration – 3*12,RUS01+RUS02(RBB 22_2B) – One RUS01 and one RUS02 connected to one DUG20 – In live network, when expansion and replacement from RUS01 to RUS02, the RBS6201 cabinet need upgrade from V2 to V3. (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 13 RRUS 02 新光纤接口 › RRUS 02 光纤借口升级至enhanced-LC借口(FullAXS) – RRUS 02 光纤和适配器 › 用于RRUS 的光纤(暂时) › 产品号:PRM 253 1633/100M – 额外的光纤适配器配对处理普通LC接头适合普通LC接头光纤 › 增强使用普通LC接头光纤施工时的灵活性 › 产品号: SDF 107 236/001 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 14 RRUS 02 光纤接口适配器安 装说明 RRUS 02 光纤接口适配器 No. : SDF 107 236/001 › 打开密封套。 › 拉出垫圈。 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 15 RRUS 02 光纤接口适配器安 装说明 › 把光纤穿过密封套,穿入管中打开密封套。 密封套支持直径4.5至9 mm光纤 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 16 RRUS 02 光纤接口适配器安 装说明 › 把垫圈套入光纤并推入管中。 › 重新装好密封圈。 暂时不要上紧! (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 17 RRUS 02 光纤接口适配器安 装说明 › 把光纤接头(LC)插入RRU光模块。 RRU (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 18 RRUS 02 光纤接口适配器安 装说明 › 把管和罩推入RRUS接口。 拉住光纤避免弯曲 RRU (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 19 RRUS 02 光纤接口适配器安 装说明 › 拧紧接口罩 RRU (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 20 RRUS 02 光纤接口适配器安 装说明 › 拧紧密封圈。 在拧紧密封圈前小心的把光纤 推 入几毫米 RRU (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 21 RRU RRUS 02 光纤走线规范 OK NOT OK 扎带 扎带 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 22 RRUS 02光纤安装/拆卸指引 安装 拆卸 RRU RRU 2 2 3 1 注意! 一定要先松开 密封圈再开密封罩 3 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 23 1 不能用力拉扯光纤 (R)RUS 02 Guidelines | Ericsson Internal | 2012-08-02 | Page 24