Uploaded by B Rambharath

Building Services Catalogue

advertisement
PERTH
MELBOURNE
BRISBANE
SYDNEY
1
JAKARTA
SINGAPORE
VISUAL INDEX
KWIK-SMART SOLUTIONS
BE1300
Swing Clip (with M10 Boss)
PAGE 17
BE1350
CLIC Clip
PAGE 20
BE1375
Pipe Slide Guide Assembly
PAGE 21
BE1405
Wall Plate Type A
PAGE 23
BE1535
RapidRail Connector 135°
(long x long)
PAGE 25
BE1310
Dual Clip (with M10 Boss) for
Plastic Pipe
PAGE 18
BE1355
CLIC Insert Nut
PAGE 20
BE1320
Kwik Clip (with M10 Boss)
PAGE 18
BE1360
Hammer-In Shoulder Stud & Plug
PAGE 20
BE1380
M10 Hanger Bolt
PAGE 22
BE1410
Wall Plate Type B
PAGE 23
BE1540
RapidRail T-Connector
PAGE 25
BE1390
Nylon Anchor Plug
PAGE 22
BE1500
RapidRail
PAGE 24
BE1545
RapidRail X-Connector
PAGE 25
2
BE1330
Riser Support (with
Cantilever) Assembly
PAGE 19
BE1335
Riser Support (with adjustable
Wall Plate) Assembly
PAGE 19
BE1365
CLIC Duo Wall Plate
PAGE 20
BE1395
Star Anchor Plug
PAGE 22
BE1525
RapidRail Connector 90°
(short x short)
PAGE 24
BE1550
RapidRail X-Connector (Top Hat)
PAGE 25
BE1370
Kwik Connect Rod Joiner
PAGE 21
BE1400
Suspension Eye
PAGE 23
BE1530
RapidRail Connector 90°
(long x long)
PAGE 24
BE1555
RapidRail Connector 200mm
PAGE 26
KWIK-SMART SOLUTIONS (Continued)
BE1505
RapidRail Slide Nut
PAGE 27
BE1570
RapidRail Prop
PAGE 26
BE1520
RapidRail End Plug
PAGE 28
BE1560
RapidRail Cantilever Arm
PAGE 28
BE1510
Hammerfix Tee-Bolt
PAGE 27
BE1580
Vibration Damper Washer M10
PAGE 29
BE1515
Swivel Ball Hanger
PAGE 27
BE1585,BE1586
Duct Bracket Type L
PAGE 29
BE1590, BE1591
Duct Type Bracket Type Z
PAGE 29
PIPE SUPPORTS
BE100
Medium Duty 2 Bolt Pipe Clamp
PAGE 30
BE105
Saddle Guide
PAGE 33
BE110
Stand Off Clip
PAGE 36
BE101
Medium Duty 3 Bolt Pipe Clamp
PAGE 31
BE106
Saddle Clamp
PAGE 33
BE111
Tail Clip
PAGE 36
BE102
Light Duty Pipe Clamp
PAGE 31
BE107
Standard U Bolt
PAGE 34
BE103
One Piece Pipe Clip
PAGE 32
BE107C
Conduit U Bolt
PAGE 34
BE114
Medium Duty Yoke Clamp
PAGE 37
3
BE103A
Stand Off Bracket
PAGE 32
BE108
Clevis Clamp
PAGE 35
BE115
Light Duty Yoke Clamp
PAGE 38
BE104
Clevis Hanger
PAGE 32
BE109
Bossed Clip
PAGE 36
PIPE SUPPORTS (Continued)
BE116 Type A
Wood Block
PAGE 39
BE116 Type A
Cork Block
PAGE 39
BE116 Type B
Wood Block
PAGE 39
BE116 Type B
Cork Block
PAGE 39
BE134
Adjustable Rollers
PAGE 40
BE133
Spur Rollers
PAGE 40
BE120
Standard Filbow
PAGE 40
BE135
Adjustable Pipe Stand
PAGE 41
BE136
Adjustable Pipe Stand
PAGE 41
THREADED COMPONENTS
BE202
All Thread Bolt
PAGE 42
BE206
Hex Connector
PAGE 42
BEAM CLAMPS AND CANTILEVERS
BE217
Plate Washer
PAGE 43
BE117
Inorganic Insulation Block
PAGE 39
BE218
Angle Cleat
PAGE 43
4
BEAM CLAMPS AND CANTILEVERS (Continued)
BE226
Beam Clamp
PAGE 43
BE224
Beam Clamp
PAGE 43
BE227
Suspension Clamp
PAGE 44
BE231
Rod Attachment
PAGE 46
BE230
Beam Clamp
PAGE 46
BE234
Beam Clamp
PAGE 47
BE240
Slotted Angle
PAGE 48
BE235
Beam Clamp
PAGE 47
BE241
Medium Duty Cantilever
PAGE 48
BE228N
Z-Beam Clamp
PAGE 45
BE228
Z-Beam Clamp
PAGE 45
BE233
Beam Clamp
PAGE 46
BE236
Beam Clamp
PAGE 47
B2513 to B2663
Channel Cantilevers
PAGE 49
BE237
Beam Clamp
PAGE 47
B2760 to B2703
Channel Cantilevers
PAGE 50
BINDER CHANNELS AND FITTINGS
B1000
B1000 Series Channels
PAGE 51
B2000
B3300
B2000 and B3300 Series Channels
PAGE 52
5
B4000
B5500
B4000 and B5500 Series Channels
PAGE 53
BINDER CHANNELS AND FITTINGS (Continued)
B1000 CI to B3016
Concrete Insert and Channel Nuts
PAGE 54
B 1031 to B 1941
Flat Channel Fittings
PAGE 57
B2024 to B3024
Two Piece Channel Clips, One Piece
Channel Clips
PAGE 55
B 1026 to B 2484
90° Channel Fittings
PAGE 58
B 1186 to B 2452
Angular Channel Fittings
PAGE 60
B 2280 to B 2521
End Caps, Closure Strip, Light Fittings
and Conduit Entry Fittings
PAGE 62
B2600
Isolation Barrier Strip
PAGE 56
B 1045 to B 5547
Z and U Channel Fittings
PAGE 59
B 2072 to B 2073
Channel Base Fittings
PAGE 61
BE 300
Cable Clamp
PAGE 62
6
BE3500
Binsulclamp
PAGE 56
TEST PLUGS AND INSTRUMENTS
Twinlok Test Plug
PAGE 68
C100D
Digital Stem Thermometer
PAGE 70
D220
Airflow Test Set
PAGE 73
B100
General Purpose Type Pressure Gauge
PAGE 69
B180
Pressure Gauge Adaptor
PAGE 69
C120
Surface Contact Thermometer
PAGE 70
D240
Flowmeters for Pipes up to 40mm
PAGE 74
7
C200
Differential Digital Thermometer
PAGE 71
C100
Dial Test Thermometer
PAGE 70
D200
Pervu Water Flow Portable Test Sets
PAGE 72
TABLE 1. STEEL PIPE NB (TO SCHEDULE 40)
Pipe
Pipe
Pipe Mass
Pipe Mass Full
Maximum
NB
O.D.
Empty kg/m
of Water kg/m
supports Span M
15
21.3
1.26
2.00
2.00
20
26.7
1.68
2.20
2.50
25
33.4
2.50
3.00
3.00
32
42.2
3.38
4.00
3.00
40
48.3
4.05
4.90
3.50
50
60.3
5.43
7.70
4.00
65
76.0
8.62
12.00
4.50
80
88.9
11.28
15.00
5.50
100
114.3
16.06
25.00
6.00
125
141.3
21.76
33.00
6.50
150
168.3
28.23
50.00
7.00
200
219.1
42.49
74.00
8.50
250
273.0
60.24
115.00
9.00
300
323.9
73.76
150.00
10.00
350
355.6
81.21
216.00
10.00
400
406.4
93.13
264.00
10.50
450
457.2
105.05
316.00
11.00
500
508.0
116.97
372.00
12.00
600
609.6
140.81
500.00
14.00
TABLE 2. COPPER TUBE
Tube Nominal
Tube
Tube Mass
Tube Mass Full
Maximum
Size
O.D.
Empty kg/m
of Water kg/m
supports Span M
15
12.7
0.30
0.39
1.50
20
19.0
0.52
0.75
1.50
25
25.4
0.83
1.25
2.00
32
31.8
1.05
1.72
2.50
40
38.1
1.27
2.27
2.50
50
51.2
1.70
3.57
3.00
65
63.5
2.14
5.07
3.00
80
76.2
3.42
7.60
4.00
100
101.6
4.58
12.18
4.00
125
127.0
5.74
17.77
4.00
150
152.4
8.58
25.86
4.00
TABLE 3. PVC PRESSURE PIPE
Pipe Nominal
Tube
Tube Mass
Tube Mass Full
Maximum
Size
O.D.
Empty kg/m
of Water kg/m
supports Span M
Vertical
Horizontal
32
42.2
0.54
1.58
1.70
0.85
40
48.2
0.69
2.05
1.80
0.90
50
60.3
1.07
3.20
2.10
1.05
65
75.3
1.66
5.00
2.40
1.20
80
88.9
2.31
6.93
2.70
1.35
100
114.3
3.83
11.51
3.00
1.50
150
168.2
8.28
24.93
4.00
2.00
200
219.1
14.12
42.32
4.60
2.30
250
281.0
-
-
5.20
2.60
300
315.0
-
-
6.00
3.00
TABLE 4. A.B.S. PIPE DURAFLOW CLASS 9
Nominal Size
Pipe O.D.
TABLE 5. HDPE PIPE
Maximum
supports Span M
Pipe O.D.
Tube Mass
Empty kg/m
Pipe Mass Full
of Water kg/m
10
17.1
0.70
32
0.26
0.79
15
21.4
0.90
40
0.33
1.24
20
26.7
1.00
50
0.42
1.94
25
33.5
1.00
56
0.48
2.44
32
42.2
1.20
63
0.54
3.09
40
48.3
1.20
75
0.65
4.39
50
60.3
1.30
90
0.91
6.32
80
88.9
1.60
110
1.36
9.44
100
114.3
1.90
160
2.85
19.96
150
168.3
2.10
200
219.0
2.40
Maximum spans are calculated assuming pipe full of water at 20°C.
Note the above information on A.B.S. Pipe was supplied by Dura Wills Pty Ltd.
PERTH
MELBOURNE
BRISBANE
SYDNEY
8
JAKARTA
SINGAPORE
Appendix A
Expansion diagram
for several types of pipe
All matter expands when warmed up and contracts when cooled down.
Especially for heating pipes which, owing to thermostat control, are
constantly undergoing temperature changes, this is of special significance.
By the use of the correct pipe supports which have the possibility to swing
or slide, high tension forces are eliminated.
TABLE 6.
length of the pipe run
Type of pipe
length of expansion in mm
Difference in temperature t in °C
Example: cCopper pipe CU, length of pipe run 30 m.
Difference in temperature 50°C
Length of expansion: 26 mm
d
PVC pipe, length of the pipe run 40 m.
Difference in temperature 40°C
Length of expansion: 13 mm x 10 = 130 mm
PERTH
MELBOURNE
BRISBANE
SYDNEY
9
JAKARTA
SINGAPORE
BINDER CHANNEL DESIGN CONSIDERATIONS
Appendix B
ENGINEERING PROPERTIES
TABLE 7.
Channel Mass
ABOUT X-X AXIS
ABOUT Y-Y AXIS
H
W
Area
I
Z
R
I
Z
R
Ref.
k/gm
mm
mm
mm2
106mm4
103mm3
mm
B1000
2.63
41
41
335
0.07
3.00
14.70
0.09
4.80
16.60
B1001
5.26
82
41
670
0.36
8.20
23.20
0.18
9.60
16.60
B2000
1.85
41
41
242
0.05
2.50
15.50
0.06
2.75
16.90
B2001
3.70
82
41
484
0.28
6.70
24.98
0.11
5.50
16.90
B3300
1.90
21
41
239
0.15
1.15
7.94
0.05
2.80
15.50
B3301
3.80
42
41
478
0.07
3.20
12.12
0.11
5.60
15.50
B4000
1.30
21
41
165
0.01
0.75
7.82
0.37
1.79
15.50
B4001
2.60
42
41
330
0.04
1.97
12.22
0.07
3.58
15.50
B5500
3.45
62
41
440
0.18
5.30
20.34
0.12
5.73
16.30
B5501
6.90
124
41
880
0.96
15.5
33.24
0.24
11.46
16.30
106mm4 103mm3
mm
TABLE 8. SAFE WORKING LOADS FOR B1010/M12 CHANNEL NUTS
USED IN BINDER CHANNELS: FACTOR OF SAFETY 3.0
Channel Reference
Slip Resistance
Pull Out Strength
kg
kg
B1000
680
907
B2000
365
453
B3300
405
634
B4000
365
453
B5500
680
907
Appendix C
BEAM AND COLUMN SAFE WORKING LOADS
y BEAM LOADS
y The following Table 8 contains safe working loads for Binder Channels when used as a simply supported beam with a
uniformly distributed load applied to the channel.
y The loads are calculated using a Safe Working Stress of 172 MPA (N/mm²).
y Should the load be a Point Load in the centre of the beam, the maximum load is multiplied by 0.50 and deflection by 0.80.
y Where moderate deflections can be tolerated i.e. deflection equal to 1/180 of the span, the reduced load is shown. Where
maximum loads do not induce a deflection in excess of 1/180 of the span, the reduced load is not required.
y Where virtually no deflection can be tolerated i.e. deflection equal to 1/360 of the span, the reduced load is shown. Where
maximum loads do not induce a deflection in excess of 1/360 of the span, the reduced load is not required.
y COLUMN LOADS
y Maximum Column Loads are given assuming ends are pinned. i.e. free length is unsupported. Should the load be
eccentric, refer to Binder Engineering for advice.
PERTH
MELBOURNE
BRISBANE
SYDNEY
10
JAKARTA
SINGAPORE
TABLE 9.
Channel
Reference
Maximum Uniform
Load kg
Defn. mm
Maximum Uniform 1/180 Span
Load kg
Defn. mm
Defn. mm
Maximum
Column Load
kg
1/360 Span
Load kg
300 LONG CHANNEL BEAM/COLUMN
B1000
1600
B1001
B2000
1130
B2001
0.35
1.70
0.83
4775
0.20
1.70
0.83
9603
0.38
1.70
0.83
3030
0.20
1.70
0.83
6083
B3300
470
0.66
1.70
0.83
3030
B3301
1360
0.40
1.70
0.83
6400
B4000
394
0.71
1.70
0.83
2050
B4001
1050
0.40
1.70
0.83
4308
B5500
3015
0.25
1.70
0.83
6270
0.13
1.70
0.83
12530
B5501
450 LONG CHANNEL BEAM/COLUMN
B1000
1068
B1001
B2000
754
B2001
0.83
2.54
1.27
4630
0.45
2.54
1.27
9340
0.86
2.54
1.27
2940
0.45
2.54
1.27
5920
B3300
315
1.50
2.54
1.27
2750
B3301
912
0.91
2.54
1.27
6095
B4000
260
1.60
2.54
1.27
1880
B4001
700
0.91
2.54
1.27
4120
B5500
2010
0.58
2.54
1.27
6100
0.33
2.54
1.27
7650
B5501
222
600 LONG CHANNEL BEAM/COLUMN
B1000
800
1.47
3.37
1.70
4460
B1001
2200
0.78
3.37
1.70
9050
B2000
560
1.52
3.37
1.70
2840
B2001
1546
0.78
3.37
1.70
5750
B3300
238
2.67
3.37
1.70
2400
B3301
684
1.62
3.37
1.70
5750
B4000
195
2.87
3.37
1.70
1680
B4001
524
1.62
3.37
1.70
3900
B5500
1507
1.00
3.37
1.70
5930
0.53
3.37
1.70
11850
B5501
150
120
750 LONG CHANNEL BEAM/COLUMN
B1000
640
2.26
4.24
2.10
4270
B1001
1760
1.24
4.24
2.10
8735
B2000
450
2.39
4.24
2.10
2730
B2001
1235
1.27
4.24
2.10
5550
B3300
190
4.16
4.24
2.10
2025
B3301
550
2.54
4.24
2.10
5350
B4000
155
4.45
4.24
2.10
1455
B4001
395
2.54
4.24
2.10
3670
B5500
1205
1.60
4.24
2.10
5730
B5501
3540
0.86
4.24
2.10
11450
B1000
535
3.27
5.08
2.54
4060
B1001
1465
1.80
5.08
2.54
8375
B2000
380
3.40
5.08
2.54
2600
B2001
1030
1.80
5.08
2.54
5325
B3300
160
5.99
5.08
148
2.54
1586
B3301
455
3.65
5.08
320
2.54
4920
120
75
900 LONG CHANNEL BEAM/COLUMN
415
280
B4000
130
6.42
5.08
52
2.54
1200
B4001
350
3.65
5.08
245
2.54
3410
B5500
1005
2.23
5.08
2.54
5515
B5501
2950
1.21
5.08
2.54
11020
PERTH
MELBOURNE
BRISBANE
SYDNEY
11
JAKARTA
SINGAPORE
Channel
Reference
Maximum Uniform
Load kg
Defn. mm
Load kg
Defn. mm
Maximum
Column Load
kg
305
2.97
3840
2.97
8000
2.97
2470
2.97
5085
Maximum Uniform 1/180 Span
Load kg
Defn. mm
1/360 Span
1050 LONG CHANNEL BEAM/COLUMN
B1000
455
4.45
5.92
B1001
1250
2.49
5.92
B2000
320
4.65
5.92
B2001
880
2.49
5.92
B3300
135
8.20
B3301
390
B4000
B4001
B5500
B5501
B1000
400
5.79
6.78
B1001
1100
3.25
6.78
B2000
285
6.07
6.78
B2001
775
3.25
6.78
B3300
120
10.67
B3301
340
6.48
B4000
100
11.40
B4001
263
6.48
B5500
755
3.96
6.78
3.38
5030
B5501
2215
2.16
6.78
3.38
10054
B1000
320
9.09
8.38
4.24
3050
B1001
880
5.05
8.38
4.24
6680
B2000
225
9.47
8.38
4.24
2005
B2001
620
5.05
8.38
4.24
4280
B3300
95
16.71
B3301
275
10.11
B4000
80
17.78
B4001
210
10.11
B5500
600
6.20
B5501
1770
3.38
8.38
98
205
5.92
50
2.97
1165
4.95
5.92
230
2.97
4440
115
8.74
5.92
38
2.97
915
300
4.95
5.92
175
2.97
3125
860
3.05
5.92
2.97
5305
2525
1.65
5.92
2.97
10554
3.38
3600
3.38
7590
3.38
2320
3.38
4835
1200 LONG CHANNEL BEAM/COLUMN
75
60
235
160
6.78
40
3.38
900
6.78
180
3.38
3920
6.78
30
3.38
700
6.78
135
3.38
2815
1500 LONG CHANNEL BEAM/COLUMN
50
35
150
100
8.38
25
4.24
8.38
115
4.24
8.38
20
4.24
8.38
85
4.24
2120
8.38
415
4.24
4480
4.24
8950
2750
1800 LONG CHANNEL BEAM/COLUMN
B1000
265
13.06
B1001
735
7.26
B2000
185
13.67
B2001
515
7.26
B3300
80
24.03
B3301
230
B4000
65
B4001
B5500
B5501
210
10.16
105
5.08
2465
10.16
510
5.08
5670
10.16
70
5.08
1645
10.16
360
5.08
3660
34
10.16
17
5.08
14.58
160
10.16
80
5.08
24.61
25
10.16
13
5.08
175
13.08
120
10.16
60
5.08
1478
500
8.92
10.16
285
5.08
3860
1475
4.85
10.16
5.08
7720
140
1910
2100 LONG CHANNEL BEAM/COLUMN
B1000
230
17.78
B1001
630
9.91
B2000
363
18.57
B2001
440
9.91
B3300
B3301
195
19.81
B4000
150
11.86
76
5.92
1840
11.86
375
5.92
4530
11.86
52
5.92
1250
11.86
265
5.92
2950
24
11.86
12
5.92
115
11.86
60
5.92
20
11.86
10
5.92
105
1400
B4001
150
19.81
90
11.86
45
5.92
1080
B5500
430
12.17
420
11.86
210
5.92
3170
B5501
1264
6.60
5.92
6350
PERTH
MELBOURNE
11.86
BRISBANE
SYDNEY
12
JAKARTA
SINGAPORE
Channel
Reference
Maximum Uniform
Load kg
Maximum Uniform 1/180 Span
Defn. mm
Load kg
1/360 Span
Defn. mm
Maximum
Column Load
kg
Load kg
Defn. mm
13.54
60
6.78
1410
13.54
290
6.78
3480
13.54
40
6.78
960
13.54
203
6.78
2280
19
13.54
10
6.78
90
13.54
45
6.78
15
13.54
7
6.78
65
13.54
34
6.78
2400 LONG CHANNEL BEAM/COLUMN
B1000
200
23.22
B1001
550
12.93
B2000
140
24.26
B2001
385
12.9
170
25.88
B3300
B3301
B4000
115
75
B4001
130
25.83
B5500
375
18.54
13.54
160
6.78
2450
B5501
1107
8.64
13.54
869
6.78
4930
15.24
46
7.62
1115
15.24
225
7.62
2750
15.24
30
7.62
755
15.24
160
7.62
1800
2700 LONG CHANNEL BEAM/COLUMN
B1000
175
29.36
B1001
490
16.36
B2000
125
30.71
B2001
345
18.26
160
32.77
B3300
B3301
B4000
90
65
15
15.24
7
7.62
70
15.24
35
7.62
10
15.24
6
7.62
B4001
115
32.77
54
15.24
27
7.62
B5500
335
20.07
255
15.24
125
7.62
1950
B5501
985
10.92
15.24
685
7.62
3900
16.94
35
8.46
16.94
185
8.46
16.94
25
8.46
16.94
130
8.46
12
16.94
6
8.46
55
16.94
30
8.46
10
16.94
5
8.46
3000 LONG CHANNEL BEAM/COLUMN
B1000
160
36.2
B1001
440
20.19
B2000
115
37.8
B2001
310
20.19
B3300
B3301
135
40.34
B4000
75
50
B4001
105
40.34
45
16.94
20
8.46
B5500
300
24.79
206
16.94
105
8.46
1570
B5501
885
13.49
16.94
555
8.46
3150
y For loads and deflections on beam/column lengths in excess of 3000mm long - refer to Binder Engineering
PERTH
MELBOURNE
BRISBANE
SYDNEY
13
JAKARTA
SINGAPORE
So we’ve introduced the first
fully-integrated pipe-fixing
system with components designed to
make every application quieter, easier,
Kwik-Smart
Solutions
quicker, more cost-effective and hasslefree.
It’s just one of the ways in which Binder
We are committed to supplying the
Engineering continues to offer
highest quality equipment, at world-
consultants, architects and plumbers
competitive prices, on time, every time.
Kwik-Smart Solutions.
Even in terms of catalogue information
and sales support, we believe Binder
Binder Engineering has long been
leads the way.
-20dB(A)
NOISE INSULATION TEST
CERTIFICATION
The reduction in noise transmission by
associated with quality, innovation and
success. As the Australasian region’s
This catalogue, which features the all-
leading manufacturer of proprietary
new Binder Kwik-Smart Solutions System
pipe supports to all types of industry,
of pipe fitting components, will prove an
Binder is regularly involved in high-
invaluable aid to consultants, architects
profile projects in Australia, Indonesia,
and installers who wish to make use of
Malaysia, Singapore, Thailand, Korea,
the very latest pipe fitting technology in
and New Zealand.
order to save time, effort, wastage and
money.
use of our rubber lined pipe clamps is
tested by independent institutes on the
basis of the requirements in DIN 4109.
The test method employed is that
described in DIN 52 218 for
measurement of noise transmission
reduction of rubber linings.
“In providing excellence in service,
The company’s manufacturing
centres are accredited to AS/NZS ISO
This range of products - which
9002 under BVQI and operate to
constitutes the first truly comprehensive
this internationally accepted
plumbing pipe fitting system to be made
quality standard.
available in the region - is the result of
listening to what our customers require
innovative designs and first-class
products, we have forged a partnership
with our clients of which we are
justifiably proud. We strive to lead,
never follow, and if at any time we can
be of assistance to your company,
and fulfilling their needs.
please contact your nearest Binder
Engineering location”.
PERTH
MELBOURNE
BRISBANE
SYDNEY
15
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
General Specifications
Rubber Lined Clips
•
Noise Insulation Reduction to DIN 4109
•
Ageing Resistant Rubber Lining
•
Metal Component Zinc Plated Carbon steel
Rapid Rail Fittings and Joiners
•
Zinc Plated Carbon Steel
Rapid Rail
•
Pre-galvanised Carbon Steel
Clic Clips
PERTH
•
Made of Polyamide 12 (recyclable)
•
Climate and Ageing resistant
•
Oil & Petrol Resistant
•
Temperature resistant between -40°C and +80°C
•
Suitable for Outdoor Installation
MELBOURNE
BRISBANE
SYDNEY
16
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Pipe Clips
All pipe clips in the Binder Kwik-Smart Solutions system come ready-assembled or are in one piece.
Swing Clip (with M10 Boss)
BE1300
Swivel bottom section of clip across pipe until bolt locates automatically.
Available in sizes from 15mm to 150mm for Cu and PVC pipe.
Pipe Size Range
Binder Description
Nominal Pipe Size Safe Load (N)
11-15
BE1300 Swing Clip with M10 Boss
15Cu
1110
19-23
BE1300 Swing Clip with M10 Boss
20Cu
1110
24-29
BE1300 Swing Clip with M10 Boss
25Cu
1110
30-35
BE1300 Swing Clip with M10 Boss
32Cu
1110
38-43
BE1300 Swing Clip with M10 Boss
40Cu & 40PVC
1240
48-54
BE1300 Swing Clip with M10 Boss
50Cu
1240
57-63
BE1300 Swing Clip with M10 Boss
65Cu & 50PVC
1470
64-67
BE1300 Swing Clip with M10 Boss
65PVC
1470
70-76
BE1300 Swing Clip with M10 Boss
80Cu
1470
79-85
BE1300 Swing Clip with M10 Boss
80PVC
1470
100-106
BE1300 Swing Clip with M10 Boss
100Cu
1800
108-116
BE1300 Swing Clip with M10 Boss
100PVC
1800
152
BE1300 Swing Clip with M10 Boss
150Cu
2940
159-168
BE1300 Swing Clip with M10 Boss
150PVC
2940
200-210
BE1300 Swing Clip with M10 Boss
200Cu
2940
PERTH
MELBOURNE
BRISBANE
SYDNEY
17
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Dual Clip (with M10 Boss) for Plastic Pipe
BE1310
Suitable for PVC and HDPE pipe from 25mm to 150mm.
Smooth inner surface facilitates longitudinal pipe movement.
Plastic Spacers prevent overtightening of clip onto the pipe.
Pipe Size Range
Binder Description
Nominal Pipe Size Safe Load (N)
25-28
BE1310 Dual Clip with M10 Boss
25 HDPE
1110
31-35
BE1310 Dual Clip with M10 Boss
32 HDPE
1110
40-43
BE1310 Dual Clip with M10 Boss
40 HDPE & 40PVC
1240
48-53
BE1310 Dual Clip with M10 Boss
50 HDPE
1240
57-63
BE1310 Dual Clip with M10 Boss
63 HDPE & 50PVC
1470
70-76
BE1310 Dual Clip with M10 Boss
65PVC & 75 HDPE
1470
79-85
BE1310 Dual Clip with M10 Boss
80PVC
1470
86-91
BE1310 Dual Clip with M10 Boss
90 HDPE
1470
108-116
BE1310 Dual Clip with M10 Boss
110 HDPE & 100PVC
1800
159-168
BE1310 Dual Clip with M10 Boss
160 HDPE & 150PVC
2940
Kwik Clip (with M10 Boss)
BE1320
Simply snaps around pipe. Available in sizes from 15mm to 65mm Cu.
Pipe Size Range
Binder Description
11-14
BE1320 Kwik Clip with M10 Boss
15Cu
1090
20-23
BE1320 Kwik Clip with M10 Boss
20Cu
1090
25-28
BE1320 Kwik Clip with M10 Boss
25Cu
1090
31-35
BE1320 Kwik Clip with M10 Boss
32Cu
1090
38
BE1320 Kwik Clip with M10 Boss
40Cu
1190
48-53
BE1320 Kwik Clip with M10 Boss
50Cu
1190
57-63
BE1320 Kwik Clip with M10 Boss
65Cu
1190
PERTH
MELBOURNE
Nominal Pipe Size Safe Load (N)
BRISBANE
SYDNEY
18
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Riser Support (with Cantilever) Assembly
BE1330
Unique rubber insulation profile grooved at the outside edges for improved performance.
Cantilever assembly with two supporting arms and one guidance clamp with limited grip
for high noise insulation.
Fitting Size Range
Binder Description
Nominal Size Safe Load (N)
110-112
BE1330 Riser standpipe support with Cantilever 100CI
Fy 3000
160-162
BE1330 Riser standpipe support with Cantilever 150CI
Fy 3000
Fy
Riser Support (with adjustable Wall Plate) Assembly
BE1335
Superior noise reduction through unique clamping system. Intermediate riser support assembly
for wall-mounted applications. Suitable for cast iron & plasic pipe.
Fitting Size Range
Binder Description
Nominal Size
Safe Load (N)
110-112
BE1335 Riser standpipe support with Wall Plate 100CI
Fy 820
160-162
BE1335 Riser standpipe support with Wall Plate 150CI
Fy 820
Fy
Fy
I
PERTH
MELBOURNE
BRISBANE
SYDNEY
19
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
CLIC Clip
BE1350
Can be fitted individually using the BE1360 Hammer-In Shoulder Stud & Plug,
(needs M6 Nut Insert) or in tandem on a BE1365 CLIC Duo Wall Plate.
Pipe Size Range
Binder Description
Nominal Pipe Size
Safe Load (N)
“11,8-14,3”
BE1350 CLIC Clip
15Cu
185
“14.3-16.8”
BE1350 CLIC Clip
16mm Yorkflex
185
“16,8-19,5”
BE1350 CLIC Clip
20Cu & 15Cu Kemlag
220
“19,5-22,0”
BE1350 CLIC Clip
15NB & 20mm Yorkflex
235
“22,0-22,8”
BE1350 CLIC Clip
20Cu Kemlag
250
“24,6-27,8”
BE1350 CLIC Clip
25Cu & 20NB
285
“31,2-35,5”
BE1350 CLIC Clip
32Cu & 25NB
340
“35,5-39,5”
BE1350 CLIC Clip
40Cu
360
“39,5-43,5”
BE1350 CLIC Clip
32NB
380
“46,5-50,5”
BE1350 CLIC Clip
40NB
435
“50,5-55,5”
BE1350 CLIC Clip
50Cu
470
“58,5-64,0”
BE1350 CLIC Clip
50NB
530
CLIC Insert Nut
BE1355
Required when using BE1350 Clic Clip with BE1360 Shoulder stud.
Fitting Size Range
Binder Description
Nominal Size
M6
BE1355 CLIC M6 Insert Nut
M6
M8
BE1355 CLIC M8 Insert Nut
M8
Hammer-In Shoulder Stud & Plug
BE1360
For use with BE1350 CLIC Clip. Simply drill hole, hammer in stud and attach Clic Clip
Fitting Size Range
Binder Description
Nominal Size
M6x40
BE1360 Hammer-In Shoulder M6 Stud & Plug
M6x40
CLIC Duo Wall Plate
BE1365
For use with BE1350 CLIC Clip.
Single point fixing, holds 2 x BE1350 Clic Clips.
Fitting Size Range
Double CLIC
Binder Description
BE1365 CLIC Duo Wall Plate
Nominal Size
All CLIC Sizes
Also available Clic Trio Wall Plate for mounting 3 Clic Clips.
PERTH
MELBOURNE
BRISBANE
SYDNEY
20
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Accessories
Kwik Connect Rod Joiner
BE1370
Simply place rods side by side and slide the unique locking mechanism into place.
Easy height adjustment.
Fitting Size Range
Binder Description
Safe Load (N)
M10
BE1370 Kwik Connect Rod Joiner
2500
Pipe Slide Guide Assembly
BE1375
Accommodates longitudinal pipe movement.
Sliding piece made of nylon with minimal friction in rail profile.
Maximum expansion 100mm.
PERTH
MELBOURNE
BRISBANE
SYDNEY
21
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Fixings
M10 Hanger Bolt
BE1380
Combine with BE 1395 Star Anchor Plug or BE 1390 Nylon Anchor Plug for easy fixing into masonry.
Hexagonal head for fine fixing. Free driver bit added with each packing.
Fitting Size Range
Binder Description
Nominal Size
Safe Load (N)
M10
BE1380 Hanger bolts
M10x80
3540
M10
BE1380 Hanger bolts
M10x100
3540
M10
BE1380 Hanger bolts
M10x120
3540
M10
BE1380 Hanger bolts
M10x140
3540
Nylon Anchor Plug
BE1390
Made of grey Polyamide 6 (nylon). Packed in display cartons.
Fitting Size Range
Binder Description
M10
BE1390 Nylon Anchor Plug for M10 Hanger Bolt
Star Anchor Plug
BE1395
Made of passivated zinc plated carbon steel.
Fitting Size Range
M10x60
Binder Description
BE1395 Star Anchor Plug for M10 Hanger Bolt
Star Anchor Plug with
Hanger Bolt Attached
PERTH
MELBOURNE
BRISBANE
SYDNEY
22
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Suspension Eye
BE1400
Closed design for maximised loading.
For use with conventional 2 piece pipe clips.
Fitting Size Range
Binder Description
Safe Load (N)
M10
BE1400 Suspension eye
3540
Wall Plate Type A
BE1405
Slots at 90° to each other to simplify fixing.
Fitting Size Range
Binder Description
Safe Load (N)
M10
BE1405 Wall Plate Type A
3800
Wall Plate Type B
BE1410
Slots at 90° to each other to simplify fixing.
Fitting Size Range
Binder Description
Safe Load (N)
M10x35
BE1410 Wall Plate Type B
2000
PERTH
MELBOURNE
BRISBANE
SYDNEY
23
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Rail
RapidRail
BE1500
Available in 2 metre lengths.
Unique double-sided application.
Accepts all RapidRail fittings with a unique push/twist/lock action.
Fitting Size Range
Binder Description
Nominal Size
30x20
BE1500 Rapid Rail WM15
30x20
90°
Rail Connectors
A comprehensive range of joining brackets is available
to enable RapidRail to be used in virtually any configuration.
RapidRail Connector 90° (short x short)
BE1525
RapidRail Connector 90° (long x long)
BE1530
PERTH
MELBOURNE
BRISBANE
SYDNEY
24
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
RapidRail Connector 135° (long x long)
BE1535
RapidRail T-Connector
BE1540
RapidRail X-Connector
BE1545
RapidRail X-Connector (Top Hat)
BE1550
PERTH
MELBOURNE
BRISBANE
SYDNEY
25
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
RapidRail Connector 200mm
BE1555
RapidRail Prop
BE1570
For fixing above, below or beside a cantilever arm for increased load bearing capacity.
Increases strength of a 90° angle made of 2 pieces of rail.
Fitting Size Range
Binder Description
Nominal Size
200 mm
BE1570 Rapidrail Prop
200mm
300 mm
BE1570 Rapidrail Prop
300mm
PERTH
MELBOURNE
BRISBANE
SYDNEY
26
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Rail Fittings
RapidRail Slide Nut
BE1505
Allows rods to be located anywhere on RapidRail.
Fitting Size Range
Binder Description
M8
BE1505 Rapidrail Slide Nut
M10
BE1505 Rapidrail Slide Nut
Hammerfix Tee-Bolt
BE1510
Allows for quick, easy and effective connection of clips to RapidRail using a push/twist/lock action. Allows slide location.
Fitting Size Range
Binder Description
M10x25 mm
BE1510 Rapidrail Hammerfix Tee-Bolt
M10x50 mm
BE1510 Rapidrail Hammerfix Tee-Bolt
M10x70 mm
BE1510 Rapidrail Hammerfix Tee-Bolt
M10x100 mm
BE1510 Rapidrail Hammerfix Tee-Bolt
Swivel Ball Hanger
BE1515
Accommodates angular pipe movement
Fitting Size Range
Binder Description
Safe Load (N)
M10
BE1415 Swivel Ball Hanger
3100
20°
20°
PERTH
MELBOURNE
BRISBANE
SYDNEY
27
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
RapidRail End Plug
BE1520
Fitting Size Range
Binder Description
30X20 mm
BE1520 Rapidrail Endcap WM 15
RapidRail Cantilever Arm
BE1560
Available in 150mm, 200mm and 250mm lengths. Fittings can be applied on both sides of rail.
Slots at 90° to each other to simplify fixing.
Fitting Size Range
Binder Description
150 mm
BE1560 Rapidrail Cantilver Arm Wm 15
200 mm
BE1560 Rapidrail Cantilver Arm Wm 15
250 mm
BE1560 Rapidrail Cantilver Arm Wm 15
Typical assembly using RapidRail Cantilever Arm
PERTH
MELBOURNE
BRISBANE
SYDNEY
28
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Vibration Damper Washer M10
BE1580
Ø30
GENERAL NOTES
Designed for M10 threaded rod.
19.5
10
y
Ø13
Duct Bracket Type L with rubber
BE1585
Duct Bracket Type L without rubber
BE1586
Application Example
(air duct supported by threaded rod)
GENERAL NOTES
y
y
y
y
Standard material Carbon Steel.
Standard finish Zinc Plated.
Holes Ø4.2mm for pop-rivet connection.
BE1585 with double EPDM rubber lining with
hole for threaded rod up to M10.
Type
G
(mm)
H
(mm)
L
(mm)
Bxs
(mm)
Safe Load
(N)
L
10.5
90
35
30 x 2
700
mounted with
4 pop rivets
Duct Bracket Type Z with rubber
BE1590
Duct Bracket Type Z without rubber
BE1591
Application Example
(air duct supported by threaded rod)
mounted with
2 pop rivets
GENERAL NOTES
y
y
y
y
Standard material Carbon Steel.
Standard finish Zinc Plated.
Holes Ø4.2mm for pop-rivet connection.
BE1590 with double EPDM rubber lining with
hole for threaded rod up to M10.
PERTH
MELBOURNE
Type
G
(mm)
H
(mm)
L
(mm)
Bxs
(mm)
Safe Load
(N)
Z
10.5
59
35
30 x 2
700
BRISBANE
SYDNEY
29
JAKARTA
SINGAPORE
Kwik-Smart
Solutions
Medium Duty 2 Bolt Pipe Clamp
BE100
DIA D
PIPE/TUBE
NOMINAL SIZE
BOLT A
CENTRES
B
MATERIAL
WxT
13
19
21
25
27
32
34
38
40
43
43
48
50
51
56
56
60
63
63
70
75
76
76
83
89
90
102
109
110
110
114
127
140
152
160
160
168
203
220
225
245
251
257
273
281
304
315
324
356
406
457
508
610
762
914
15 Cu
20 Cu
15 NB / PP
25 Cu
20 NB / PP
32 Cu / HDPE
25 NB / PP
40 Cu
40 HDPE
32 NB / PP
40 NH
40 NB / PP
50 HDPE
50 Cu
50 NH
56 HDPE
50 NB
63 HDPE
65 Cu
65 NH
75 HDPE
65 NB
80 Cu
80 NH
80 NB
90 HDPE
100 Cu
100 CI
100 NH
110 HDPE
100 NB / PP
125 Cu
125 NB / PP
150 Cu
150 NH / PP
160 HDPE
150 NB / CI
200 Cu
200 NB
200 PP
225 NB / CI
225 PP
250 Cu
250 NB
250 PP
300 Cu
300 PP
300 NB
350 NB
400 NB
450 NB
500 NB
600 NB
750 NB
900 NB
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M10 x 30
M12 x 40
M12 x 40
M12 x 40
M12 x 40
M12 x 40
M12 x 40
M12 x 40
M12 x 40
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M16 x 50
M20 x 75
M24 x 80
M24 x 90
M24 x 90
M24 x 90
M24 x 90
M30 x 100
M30 x 100
40
56
56
66
66
69
69
88
88
88
88
97
97
82
95
95
100
112
112
115
115
115
115
129
135
135
150
160
160
160
160
180
205
205
215
215
225
255
290
275
320
325
335
350
360
380
390
420
460
530
620
670
780
930
1120
25 x 3
25 x 3
25 x 3
25 x 3
25 x 3
25 x 3
25 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
32 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 3
40 x 5
40 x 5
40 x 5
40 x 5
40 x 5
40 x 5
40 x 5
50 x 6
50 x 6
50 x 6
50 x 6
50 x 6
50 x 6
50 x 6
50 x 6
50 x 6
50 x 10
65 x 10
65 x 12
75 x 16
75 x 16
75 x 16
90 x 20
100 x 25
PERTH
MELBOURNE
BRISBANE
SYDNEY
30
GENERAL NOTES
y
y
y
y
y
y
NB
Cu
NH
PP
CI
HDPE
Indicates Steel Pipe Nominal Bore.
Indicates Copper Pipe.
Indicates PVC Pipe.
Indicates PVC Pressure Pipe.
Indicates Cast Iron Pipe
Indicates High Density Polyethylene Pipe
y Standard Clamp Material Carbon Steel.
y Standard Clamp Finish Hot Dip Galvanised.
y Other Finishes Available Zinc Plated, Plastic Coated for
Cu or PVC Pipes or Painted to Client Specification.
y Clamp can be supplied in other diameters or materials
upon request
y WHEN ORDERING, PLEASE SPECIFY DIAMETER AND
IF AN ALTERNATIVE FINISH IS REQUIRED.
JAKARTA
SINGAPORE
Medium Duty 3 Bolt Pipe Clamp
DIA D
PIPE NB
BOLT A
21
15NB
27
34
CENTRES
BE101
MATERIAL
B
C
WxT
M6 x 25
56
60
25 x 3
20NB
M6 x 25
66
60
25 x 3
25NB
M6 x 25
69
60
25 x 3
43
32NB
M10 x 30
88
60
32 x 3
48
40NB
M10 x 30
97
60
32 x 3
60
50NB
M10 x 30
100
60
32 x 3
76
65NB
M10 x 30
115
60
40 x 3
89
80NB
M10 x 30
135
60
40 x 3
114
100NB
M12 x 40
160
60
40 x 3
140
125NB
M12 x 40
205
80
40 x 5
168
150NB
M12 x 40
225
80
40 x 5
220
200NB
M16 x 50
290
90
50 x 6
245
225NB
M16 x 50
320
90
50 x 6
273
250NB
M16 x 50
350
90
50 x 6
324
300NB
M20 x 75
420
90
50 x 10
356
350NB
M24 x 80
460
90
65 x 10
406
400NB
M24 x 90
530
90
65 x 12
457
450NB
M24 x 90
620
90
75 x 16
508
500NB
M24 x 90
670
90
75 x 16
610
600NB
M24 x 90
780
90
75 x 16
762
750NB
M30 x 100
930
100
90 x 20
914
900NB
M30 x 100
1120
100
100 x 25
Light Duty Pipe Clamp
DIA D
PIPE/TUBE
NOMINAL SIZE
BOLT A
CENTRES
B
13
15 Cu
M6 x 25
56
19
20 Cu
M6 x 25
56
21
15 NB / PP
M6 x 25
56
25
25 Cu
M6 x 25
66
27
20 NB / PP
M6 x 25
66
32
32 Cu / HDPE
M6 x 25
69
34
25 NB / PP
M6 x 25
69
38
40 Cu
M8 x 30
78
40
40 HDPE
M8 x 30
80
43
32 NB / PP
M8 x 30
82
43
40 NH
M8 x 30
82
48
40 NB / PP
M8 x 30
88
50
50 HDPE
M8 x 30
90
51
50 Cu
M8 x 30
90
56
50 NH
M8 x 30
95
56
56 HDPE
M8 x 30
95
60
50 NB
M8 x 30
100
63
63 HDPE
M8 x 30
105
63
65 Cu
M8 x 30
105
70
65 NH
M8 x 30
110
75
75 HDPE
M8 x 30
115
76
65 NB / PP
M8 x 30
115
76
80 Cu
M8 x 30
115
83
80 NH
M8 x 30
120
89
80 NB
M8 x 30
130
90
90 HDPE
M8 x 30
130
102
100 Cu
M8 x 30
140
109
100 CI
M8 x 30
145
110
100 NH
M8 x 30
145
110
110 HDPE
M8 x 30
145
114
100 NB / PP
M8 x 30
155
127
125 Cu
M8 x 30
165
140
125 NB / PP
M8 x 30
180
152
150 Cu
M8 x 30
190
160
150 NH / PP
M8 x 30
200
160
160 HDPE
M8 x 30
200
168
150 NB / CI
M8 x 30
210
PERTH
MELBOURNE
BE102
GENERAL NOTES
y
y
y
y
y
y
NB
Cu
NH
PP
CI
HDPE
Indicates Steel Pipe Nominal Bore.
Indicates Copper Pipe.
Indicates PVC Pipe.
Indicates PVC Pressure Pipe.
Indicates Cast Iron Pipe
Indicates High Density Polyethylene Pipe
y Standard Clamp Material Carbon Steel.
y Standard Clamp Finish Hot Dip Galvanised.
y Other Finishes Available Zinc Plated, Plastic Coated for Cu or PVC Pipes or Painted to
Client Specification.
y Clamp can be supplied in other diameters or materials upon request
y WHEN ORDERING, PLEASE SPECIFY DIAMETER AND IF AN ALTERNATIVE FINISH IS REQUIRED.
BRISBANE
SYDNEY
31
JAKARTA
SINGAPORE
One Piece Pipe Clip
DIA D
PIPE/TUBE
NOMINAL SIZE
CENTRES MATERIAL
B
WxT
15 Cu
M6 x 25
20
25 x 1.0
19
20 Cu
M6 x 25
24
25 x 1.0
21
15 NB
M6 x 25
26
25 x 1.0
25
25 Cu
M6 x 25
28
25 x 1.0
27
20 NB
M6 x 25
30
25 x 1.0
32
32 Cu
M6 x 25
30
25 x 1.0
34
25 NB
M6 x 25
32
25 x 1.0
38
40 Cu
M8 x 30
34
32 x 1.6
43
32 NB
M8 x 30
36
32 x 1.6
48
40 NB
M8 x 30
38
32 x 1.6
51
50 Cu
M8 x 30
40
32 x 1.6
60
50 NB
M8 x 30
45
32 x 1.6
63
65 Cu
M8 x 30
50
32 x 1.6
76
65 NB
M8 x 30
55
32 x 1.6
76
80 Cu
M8 x 30
55
32 x 1.6
89
80 NB
M8 x 30
60
32 x 2
102
100 Cu
M8 x 30
65
32 x 2
114
100 NB
M8 x 30
75
32 x 2
127
125 Cu
M8 x 30
85
32 x 3
140
125 NB
M8 x 30
95
32 x 3
152
150 Cu
M8 x 30
95
32 x 3
168
150 NB
M8 x 30
100
32 x 3
13
y
y
y
y
y
y
SCREW A
BE103
Standard Finish Galvabond.
NB Indicates Steel Pipe Nominal Bore
Std. Finish - 13 dia to 114 dia Galvabond.
Cu Indicates Copper Tube
Std. Finish - 127 dia to 168 dia Hot Dip Galvanised.
Other Finish Available: Plastic Coated.
The Clips can be manufactured in other diameters and materials to request.
The Clip can be supplied complete with BE116 Cork/Wood Blocks and BE104 Clevis Hanger.
y WHEN ORDERING, PLEASE SPECIFY DIAMETER AND FINISH REQUIRED.
Stand Off Bracket
BE103A
GENERAL NOTES
y Standard Finish Galvabond.
Clevis Hanger
BE104
ROD
HOLE
DIA A
DIA D
M6
7
70
20 x 3
M8
9
75
25 x 3
M10
11
80
25 x 3
M10
11
95
40 x 3
M12
14
95
40 x 6
M16
18
130
50 x 6
M20
22
140
75 x 10
M24
27
140
75 x 10
B
MATERIAL
WxT
GENERAL NOTES
y BE104 Clevis is used to connect a BE202 Threaded Rod
to a Pipe Clip. It allows vertical adjustment of the Rod.
y Standard Finish: Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY CONDUIT DIAMETER.
PERTH
MELBOURNE
BRISBANE
SYDNEY
32
JAKARTA
SINGAPORE
Saddle Guide
BE105
Saddle Clamp
BE106
BE105 SADDLE GUIDE
BE106 CLAMP
H
WxT
B
M
B
M
13
15 Cu
8
25 x 3
65
16
59
10
19
20 Cu
8
25 x 3
71
22
65
16
21
15 NB / PP
8
25 x 3
73
24
67
18
25
25 Cu
8
25 x 3
77
28
71
22
27
20 NB / PP
8
25 x 3
79
30
73
24
32
32 Cu / HDPE
8
25 x 3
84
35
78
29
34
25 NB / PP
8
25 x 3
86
37
80
31
38
40 Cu
11
32 x 3
100
41
94
35
40
40 HDPE
11
32 x 3
105
46
99
40
43
32 NB
11
32 x 3
105
46
99
40
43
40 NH
11
32 x 3
105
46
99
40
48
40 NB / PP
11
32 x 3
110
51
104
43
50
50 HDPE
11
32 x 3
113
54
107
48
51
50 Cu
11
32 x 3
113
54
107
48
56
50 NH
11
32 x 3
118
59
112
53
56
56 HDPE
11
32 x 3
118
59
112
53
60
50 NB
11
32 x 3
122
63
116
57
63
63 HDPE
14
40 x 3
126
67
120
61
63
65 Cu
14
40 x 3
126
67
120
61
70
65 NH
14
40 x 3
132
73
126
67
75
75 HDPE
14
40 x 3
138
79
132
73
76
65 NB / PP
14
40 x 3
138
79
132
73
76
80 Cu
14
40 x 3
138
79
132
73
83
80 NH
14
40 x 3
145
86
139
80
89
80 NB
14
40 x 3
151
92
145
86
90
90 HDPE
14
40 x 3
151
92
145
86
H
B
Optional
Polypropolene
for Copper Tube
BE106 SADDLE CLAMP
A
DI
B
100 Cu
14
40 x 3
164
105
158
99
109
100 CI
14
40 x 3
172
113
166
107
110
100 NH
14
40 x 3
172
113
166
107
110
110 HDPE
14
40 x 3
172
113
166
107
114
100 NB / PP
14
40 x 3
176
117
170
111
127
125 Cu
14
40 x 5
207
132
197
122
140
125 NB / PP
14
40 x 5
220
145
210
135
152
150 Cu
14
40 x 5
232
157
222
147
160
150 NH / PP
14
40 x 5
240
165
230
155
160
160 HDPE
14
40 x 5
240
165
230
155
168
150 NB / CI
14
40 x 5
248
173
238
163
203
200 Cu
14
40 x 5
283
208
273
198
220
200 NB
18
50 x 6
315
226
303
214
225
200 PP
18
50 x 6
330
231
318
219
245
225 NB / CI
18
50 x 6
340
251
328
239
251
225 PP
18
50 x 6
346
257
334
245
257
250 Cu
18
50 x 6
352
263
340
251
y
273
250 NB
18
50 x 6
368
279
356
267
281
250 PP
18
50 x 6
376
287
364
275
y
304
300 Cu
18
50 x 6
399
310
387
298
315
300 PP
18
50 x 6
410
321
398
309
324
300 NB
22
50 x 10
439
334
419
314
356
350 NB
22
75 x 10
471
366
451
346
406
400 NB
27
75 x 12
554
418
530
394
457
450 NB
27
75 x 12
605
469
581
445
508
500 NB
27
75 x 12
656
520
632
496
610
600 NB
27
75 x 12
758
622
734
598
MELBOURNE
BRISBANE
SYDNEY
33
D
H
102
PERTH
D
A
DI
M
NOMINAL SIZE
BE105 GUIDE
M
D
HOLE DIA MATERIAL
WxT
PIPE/TUBE
WxT
DIA
Optional
Polypropolene
for Copper Tube
WHEN ORDERING, PLEASE SPECIFY
DIAMETER AND FINISH REQUIRED.
GENERAL NOTES
y NB
y
y
y
y
y
y
y
y
Indicates Steel Pipe Nominal Bore.
Std. Finish - Hot Dip Galvanised.
Cu
Indicates Copper Pipe.
Std. Finish - Black Plastic Coated or Hot Dip Galvanised.
NH
Indicates PVC Pipe.
Std. Finish - White Plastic Coated or Hot Dip Galvanised.
PP
Indicates PVC Pressure Pipe.
Std. Finish - White Plastic Coated or Hot Dip Galvanised.
CI
Indicates Cast Iron Pipe
Std. Finish - Hot Dip Galvanised.
HDPE Indicates High Density Polyethylene Pipe
Std. Finish - Hot Dip Galvanised.
The BE105 Saddle Guide is manufactured with a clearance
gap around the pipe to allow for free movement of the pipe.
The BE106 is manufactured with a tight fit around the pipe
and a pull down to clamp the pipe.
For Copper Tube the saddle is normally supplied plastic
coated to give a barrier between the copper and steel. A
Polypropolene strip can be supplied on request for the
copper tube to sit on thus isolating the copper from the
supporting steelwork.
Nuts and bolts can be supplied with the saddles on request.
Standard Saddle Material - Carbon Steel.
JAKARTA
SINGAPORE
Standard U Bolt
BE107
CENTRES
THREAD
A
LENGTH B
15NB
31
45
67
M10
20NB
37
50
80
M10
34
25NB
44
50
87
M10
43
32NB
53
50
92
M10
48
40NB
58
50
100
M10
60
50NB
70
50
110
M10
76
65NB
87
50
125
M12
89
80NB
101
50
142
M12
114
100NB
127
50
165
M12
140
125NB
152
50
187
M12
168
150NB
178
50
220
M12
220
200NB
236
75
300
M16
273
250NB
295
100
378
M20
324
300NB
345
100
425
M20
356
350NB
382
100
430
M24
406
400NB
430
100
490
M24
457
450NB
482
100
550
M24
508
500NB
535
100
590
M24
610
600NB
635
100
690
M24
DIA D
PIPE NB
21
27
C
THREAD
DIA E
GENERAL NOTES
y NB Indicates Steel Pipe Nominal Bore. Std. Finish - Hot Dip Galvanised.
y The BE107 U bolt is supplied with 2 hex nuts as standard.
y Other pipe/thread diameters on request.
y WHEN ORDERING, PLEASE SPECIFY PIPE NB REQUIRED.
Conduit U Bolt
BE107C
DIA
CONDUIT
CENTRES
D
DIA
A
22
20
28
40
28
25
34
44
36
30
42
51
44
40
50
60
54
50
60
70
C
GENERAL NOTES
y Standard Finish: Zinc Plated or Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY CONDUIT DIAMETER.
PERTH
MELBOURNE
BRISBANE
SYDNEY
34
JAKARTA
SINGAPORE
Clevis Clamp
BE108
DIA
D
PIPE/NOMINAL
SIZE
A
CLAMP BOLT
DIA B
ROD
DIA C
21
27
34
43
48
60
76
89
114
168
220
273
324
356
406
457
508
610
15NB
20NB
25NB
32NB
40NB
50NB
65NB
80NB
100NB
150NB
200NB
250NB
300NB
350NB
400NB
450NB
500NB
600NB
60
64
65
72
76
82
105
110
140
183
215
255
283
305
336
390
440
495
M6
M6
M6
M10
M10
M10
M12
M12
M12
M16
M16
M20
M20
M20
M24
M24
M24
M24
M6
M6
M6
M10
M10
M10
M12
M12
M12
M16
M16
M20
M20
M24
M24
M24
M30
M30
MATERIAL
W1 x T1 W2 x T2
25 x 3
25 x 3
25 x 3
32 x 3
32 x 3
32 x 3
40 x 3
40 x 3
40 x 3
50 x 6
50 x 6
50 x 6
50 x 10
65 x 10
65 x 10
75 x 10
75 x 12
75 x 12
25 x 3
25 x 3
25 x 3
32 x 3
32 x 3
32 x 3
40 x 5
40 x 5
40 x 5
50 x 6
50 x 10
50 x 10
50 x 12
65 x 12
65 x 12
75 x 12
75 x 16
75 x 16
GENERAL NOTES
y NB Indicates Steel Pipe Nominal Bore. Std. Finish - Hot Dip Galvanised.
y Standard Material - Carbon Steel.
y The BE108 Clevis Clamp can be manufactured in other diameters and materials to request.
y WHEN ORDERING, PLEASE SPECIFY NB REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
35
JAKARTA
SINGAPORE
Bossed Clip BE109
DIA
D
13
19
21
25
27
32
34
38
43
48
51
56
60
63
70
76
83
89
102
110
114
152
160
PIPE/TUBE
NOMINAL SIZE
15 Cu
20 Cu
15 NB
25 Cu
20 NB
32 Cu
25 NB
40 Cu
32 NB / 40 NH
40 NB
50 Cu
50 NH
50 NB
65 Cu
65 NH
65 NB / 80 Cu
80 NH
80 NB
100 Cu
100 NH
100 NB
150 Cu
150 NH
SCREW
A
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 20
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M6 x 25
M8 x 25
M8 x 25
M8 x 25
Stand Off Clip BE110
CENTRES
B
33
49
40
52
50
65
57
65
75
73
85
92
88
95
106
105
115
120
138
148
145
193
200
HOLE
DIA E
7
7
7
7
7
7
7
7
7
7
7
7
7
7
11
11
HEIGHT C
(BE110 ONLY)
16
22
28
35
41
46
54
59
67
73
79
86
105
113
155
163
BE111 TAIL CLIP
Tail Clip BE111
BE109 BOSSED CLIP
BE110 STAND OFF CLIP
GENERAL NOTES
y NB
y Cu
y NH
Indicates Steel Pipe Nominal Bore.
Indicates Copper Pipe.
Indicates PVC Pipe.
Std. Finish - Hot Dip Galvanised.
Std. Finish - Black Plastic Coated.
Std. Finish - White Plastic Coated.
y The Clips can be manufactured in other diameters and materials to request.
y WHEN ORDERING, PLEASE SPECIFY CLIP TYPE AND PIPE /TUBE NOMINAL SIZE
PERTH
MELBOURNE
BRISBANE
SYDNEY
36
JAKARTA
SINGAPORE
Medium Duty Yoke Clamp
BE114
DIA
PIPE/TUBE
BOLT
CENTRES
ROD DIA
HEIGHT
D
NOMINAL SIZE
A
B
C
H
MATERIAL
WxT
13
15 Cu
M6 x 25
40
M10
50
25 x 3
19
20 Cu
M6 x 25
56
M10
50
25 x 3
21
15 NB
M6 x 25
56
M10
50
25 x 3
25
25 Cu
M6 x 25
66
M10
50
25 x 3
27
20 NB / PP
M6 x 25
66
M10
50
25 x 3
32
32 Cu / HDPE
M6 x 25
69
M10
50
25 x 3
34
25 NB / PP
M6 x 25
69
M10
55
25 x 3
38
40 Cu
M10 x 30
88
M10
55
32 x 3
40
40 HDPE
M10 x 30
88
M10
60
32 x 3
43
32 NB / PP
M10 x 30
88
M10
60
32 x 3
43
40 NH
M10 x 30
88
M10
65
32 x 3
48
40 NB / PP
M10 x 30
97
M10
65
32 x 3
50
50 HDPE
M10 x 30
97
M10
65
32 x 3
51
50 Cu
M10 x 30
82
M10
65
32 x 3
56
50 NH
M10 x 30
95
M10
65
32 x 3
56
56 HDPE
M10 x 30
95
M10
65
32 x 3
60
50 NB
M10 x 30
100
M10
75
32 x 3
63
63 HDPE
M10 x 30
112
M10
75
40 x 3
63
65 Cu
M10 x 30
112
M10
75
40 x 3
70
65 NH
M10 x 30
115
M12
75
40 x 3
75
75 HDPE
M10 x 30
115
M12
90
40 x 3
76
65 NB
M10 x 30
115
M12
90
40 x 3
76
80 Cu
M10 x 30
115
M12
90
40 x 3
83
80 NH
M10 x 30
129
M12
90
40 x 3
89
80 NB
M10 x 30
135
M12
100
40 x 3
90
90 HDPE
M10 x 30
135
M12
100
40 x 3
102
100 Cu
M10 x 30
150
M12
110
40 x 3
109
100 CI
M10 x 30
160
M12
110
40 x 3
110
100 NH
M10 x 30
160
M12
110
40 x 3
110
110 HDPE
M10 x 30
160
M12
110
40 x 3
114
100 NB / PP
M12 x 40
160
M12
115
40 x 3
127
125 Cu
M12 x 40
180
M12
125
40 x 5
140
125 NB / PP
M12 x 40
195
M12
130
40 x 5
150
125 Cu
M12 x 40
205
M12
140
40 x 5
152
150 Cu
M12 x 40
205
M12
140
40 x 5
160
150 NH / PP
M12 x 40
215
M12
145
40 x 5
168
150 NB / CI
M12 x 40
225
M12
150
40 x 5
203
200 Cu
M12 x 40
255
M12
170
40 x 5
220
200 NB
M16 x 50
270
M16
175
50 x 6
225
200 PP
M16 x 50
275
M16
180
50 x 6
245
225 NB / CI
M16 x 50
320
M16
200
50 x 6
251
225 PP
M16 x 50
325
M16
200
50 x 6
257
250 Cu
M16 x 50
335
M16
205
50 x 6
273
250 NB
M16 x 50
350
M16
210
50 x 6
281
250 PP
M16 x 50
360
M16
220
50 x 6
304
300 Cu
M16 x 50
380
M16
230
50 x 6
315
300 PP
M16 x 50
390
M16
240
50 x 6
324
300 NB
M20 x 75
420
M20
250
50 x 10
PERTH
MELBOURNE
BRISBANE
SYDNEY
37
GENERAL NOTES
y NB
y
y
y
y
y
Indicates Steel Pipe Nominal Bore.
Std. Finish - Hot Dip Galvanised.
Cu
Indicates Copper Pipe.
Std. Finish - Black Plastic Coated
NH
Indicates PVC Pipe.
Std. Finish - White Plastic Coated
PP
Indicates PVC Pressure Pipe.
Std. Finish - White Plastic Coated
CI
Indicates Cast Iron Pipe
Std. Finish - Hot Dip Galvanised.
HDPE Indicates High Density Polyethylene Pipe
Std. Finish - Hot Dip Galvanised.
y Standard Clamp Material Carbon Steel.
y Clamps can be manufactured in other diameters and
materials to request.
y WHEN ORDERING, PLEASE SPECIFY DIAMETER
AND FINISH REQUIRED.
JAKARTA
SINGAPORE
Light Duty Yoke Clamp
BE115
DIA
PIPE/TUBE
BOLT
CENTRES
D
NOMINAL SIZE
A
B
HEIGHT
H
13
15 Cu
M6 x 25
56
50
19
20 Cu
M6 x 25
56
50
21
15 NB / PP
M6 x 25
56
50
25
25 Cu
M6 x 25
66
50
27
20 NB / PP
M6 x 25
66
50
32
32 Cu / HDPE
M6 x 25
69
50
34
25 NB / PP
M6 x 25
69
55
38
40 Cu
M8 x 30
78
55
40
40 HDPE
M8 x 30
80
60
43
32 NB / PP
M8 x 30
82
60
43
40 NH
M8 x 30
82
60
48
40 NB / PP
M8 x 30
88
65
50
50 HDPE
M8 x 30
90
65
51
50 Cu
M8 x 30
90
65
56
50 NH
M8 x 30
95
70
56
56 HDPE
M8 x 30
95
70
60
50 NB
M8 x 30
100
70
63
63 HDPE
M8 x 30
105
70
63
65 Cu
M8 x 30
105
70
70
65 NH
M8 x 30
110
80
75
75 HDPE
M8 x 30
115
80
76
65 NB / PP
M8 x 30
115
80
76
80 Cu
M8 x 30
115
80
83
80 NH
M8 x 30
120
80
89
80 NB
M8 x 30
130
85
90
90 HDPE
M8 x 30
130
85
102
100 Cu
M8 x 30
140
95
109
100 CI
M8 x 30
145
95
110
100 NH
M8 x 30
145
95
110
110 HDPE
M8 x 30
145
95
114
100 NB / PP
M8 x 30
155
100
127
125 Cu
M8 x 30
165
105
140
125 NB / PP
M8 x 30
180
115
150
150 HDPE
M8 x 30
190
120
152
150 Cu
M8 x 30
190
120
160
150 NH / PP
M8 x 30
200
125
168
150 NB / CI
M8 x 30
210
125
GENERAL NOTES
y
y
y
y
y
y
NB
Cu
NH
PP
CI
HDPE
Indicates Steel Pipe Nominal Bore.
Indicates Copper Pipe.
Indicates PVC Pipe.
Indicates PVC Pressure Pipe.
Indicates Cast Iron Pipe
Indicates High Density Polyethylene Pipe
Std. Finish - Hot Dip Galvanised or Zinc Plated.
Std. Finish - Black Plastic Coated or Hot Dip Galvanised.
Std. Finish - White Plastic Coated or Hot Dip Galvanised.
Std. Finish - White Plastic Coated or Hot Dip Galvanised.
Std. Finish - Hot Dip Galvanised or Zinc Plated.
Std. Finish - Hot Dip Galvanised.
y Standard Clamp Material Carbon Steel.
y Clamps can be manufactured in other diameters and materials to request i.e. Stainless Steel
y WHEN ORDERING, PLEASE SPECIFY DIAMETER AND FINISH REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
38
JAKARTA
SINGAPORE
Wood Block
Cork Block
Wood Block
Cork Block
BE116 TYPE A
BE116 TYPE A
BE116 TYPE B
BE116 TYPE B
y Wood and Cork Blocks available in all sizes of Pipe and Tube with Inulation
Thickness from 12mm to 100mm.
y WHEN ORDERING, PLEASE SPECIFY PIPE/TUBE SIZE AND INSULATION THICKNESS.
Inorganic Insulation Block
BE117
PU-block:
Polyurethane Hard Foam, with closed cells.
Density: 80 kp/m3
cold rushing strength: 7 kgs/cm2
fire classification: B 2 (acc. to DIN 4102)
wrapped in aluminium foil, smooth surface
interlocking joint
temperature resistance: from -50oC to +110oC
thermal conductivity: 0,030 W/mK
insulation thickness: 20, 30, 40 and 50mm
length of the block: 100 and 250mm
other sizes upon request
Insulation Clamps can be supplied with
or without DMG sound insulation lining.
Examples of Application:
y to avoid thermal conduction through the pipe support carrying
refrigeration pipes.
y to avoid the formation of condensation on the clamp (also on
cold water pipes.)
y as load bearing block in the clamp when compressible
insulation is being used.
y available to suit all sizes of pipe and tube with insulation
thickness from 20mm to 100mm.
Mounting Instructions:
The load bearing blocks should match the insulation thickness. The
joints should be sealed to form a vapour seal, e.g. by gluing or with
self-adhesive tapes. To achieve a vapour seal, it is usually required
to have the self-adhesive tapes overlapping 50mm on each side.
For these cases it is advisable to use the 250mm long blocks.
For heavier pipes of approx. 125mm and upwards it is advisable to
use load bearing sleeves or semi-sleeves made of metal between
the block and the clamp.
GENERAL NOTES
y BE133 Spur Rollers are suitable for diameters 21 to 168.
y Standard Finish - Hot Dip Galvanised
y WHEN ORDERING, PLEASE SPECIFY REF. NO. REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
39
JAKARTA
SINGAPORE
Standard Filbow
BE120
DIA
PIPE
DROP ROD
D
NOMINAL BORE
21
15NB
31
M10
27
20NB
35
M10
34
25NB
39
M10
43
32NB
45
M10
48
40NB
55
M10
60
50NB
66
M10
76
65NB
78
M10
89
80NB
95
M10
114
100NB
142
M10
140
125NB
155
M12
168
150NB
177
M12
219
200NB
242
M16
A
ROD DIA B
DI
A
D
A
DIA B
GENERAL NOTES
y NB
Indicates Steel Pipe Nominal Bore.
Std. Finish -
Galvabond
y BE120 is a Lindapter product which carries Factory Mutual approval
for the suspension of pipework used in fire sprinkler installations.
y WHEN ORDERING, PLEASE SPECIFY DIAMETER REQUIRED.
Spur Rollers
BE133
Adjustable Rollers
BE134
REF
LENGTH L
BE134A
170
PIPE SIZE
27 to 140
BE134B
190
140 to 216
BE134C
216
216 to 324
BE134D
243
324 to 406
GENERAL NOTES
y BE133 Spur Rollers are suitable for diameters 21 to 168.
y Standard Finish - Hot Dip Galvanised.
y Channel shown for illustration purposes only BE133 requires site assembly.
y WHEN ORDERING, PLEASE SPECIFY REF. NO. REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
40
JAKARTA
SINGAPORE
Adjustable Pipe Stand
BE135
Adjustable Pipe Stand
BE136
BE135
DIA
D
60
76
89
114
168
220
273
324
356
406
457
508
610
BE136
PIPE/TUBE
PIPE NB
NOMINAL BORE
B
50NB
40NB
65NB
40NB
80NB
50NB
100NB
65NB
150NB
65NB
200NB
65NB
250NB
65NB
300NB
65NB
350NB
80NB
400NB
80NB
450NB
100NB
500NB
100NB
600NB
100NB
PIPE NB
C
50NB
50NB
65NB
80NB
80NB
80NB
80NB
80NB
100NB
100NB
150NB
150NB
150NB
BASE PLATE
AxA
150 x 150 x 8
150 x 150 x 8
150 x 150 x 10
150 x 150 x 10
200 x 200 x 12
250 x 250 x 12
250 x 250 x 12
250 x 250 x 12
300 x 300 x 16
300 x 300 x 16
350 x 350 x 20
350 x 350 x 20
350 x 350 x 20
WxT
50 x 6
50 x 6
65 x 6
75 x 10
75 x 10
75 x 10
75 x 10
75 x 10
100 x 12
100 x 12
200 x 16
200 x 16
200 x 16
GENERAL NOTES
Ÿ BE135 and BE136 Stands allow vertical adjustment of the supported pipe by the lock nut.
When the desired height is reached, the lock nut should be welded to the support pipe C.
Ÿ Standard Finish: Hot Dip Galvanised.
Ÿ WHEN ORDERING, PLEASE SPECIFY HEIGHT L AND FIXING HOLES E REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
41
JAKARTA
SINGAPORE
All Thread Rod
BE202
THREAD DIA D
M6
M8
M10
M12
M16
M20
M24
M30
Maximum Load kg at 100oC
109
150
280
510
850
1300
2250
3700
GENERAL NOTES
y Material Carbon Steel to BHP Ref. C1008
y Standard stock lengths 3.0m, other lengths are available on request
y Standard finish Zinc Plated to AS1789, available in Hot Dip Galvanised to AS1650 on request.
Hex Connector
THREAD
DIA D
L
Maximum
Load kg
BE206
M6
M8
M10
M12
M16
M20
M24
M30
M36
M42
M56
22
25
30
40
45
60
75
75
85
100
140
100
150
230
430
690
1030
1880
2360
3050
6000
10000
GENERAL NOTES
y Standard finish Zinc Plated or Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY THREAD DIA REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
42
JAKARTA
SINGAPORE
Plate Washer
BE217
Angle Cleat
BE218
HOLE
DIA D
A
T
11 or 14
40
5
14 or 18
50
6
18 or 22
75
8
22 or 27
100
10
27 or 33
150
12
GENERAL NOTES
y Standard material Carbon Steel.
y Standard finish Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY TYPE AND HOLE DIA REQUIRED.
Beam Clamp
BE224
GENERAL NOTES
y BE224 Beam Clamp is used to clamp all Binder Channels to
structural steel beams.
y BE224 Beam Clamp should be fixed onto both flanges of the
structural steel beam.
y BE224 Beam Clamp is available in M10, M12 or M16 Fixings.
y BE224 Beam Clamp can be supplied with the appropriate
Channel Clip and Bolt, refer page 53 for details of the
Channel Clips.
y Standard Beam Clamp Material Carbon Steel.
y Standard Finish Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY BOLT DIAMETER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
43
JAKARTA
SINGAPORE
Beam Clamp
BE226
WEIGHT
SAFE WORKING
kg/ea
LOAD N
0-18
0.080
1000
10
0-20
0.135
1400
10
0-23
0.175
2800
A
B
C
D
E
M
N
M8
20
20
36
9
37
8
M10
24
22
41
11
41
M12
28
24
45
13
50
Suspension Clamp
DROP ROD
BE227
A
B
C
E
WxT
M6
30
40
60
11
40 x 5
M8
30
40
60
11
40 x 5
M10
30
40
60
11
40 x 5
M12
50
40
65
11
40 x 6
M16
50
50
100
14
50 x 6
M20
65
65
100
18
50 x 10
M24
65
65
100
22
50 x 10
DIA
GENERAL NOTES
y Standard material Carbon Steel.
y Standard finish Hot Dip Galvanised.
y BE227 can be suspended from Steel, Soffit or ant Binder Channels.
y WHEN ORDERING, PLEASE SPECIFY DROP ROD DIA REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
44
JAKARTA
SINGAPORE
Z Beam Clamp
BE228
The lindapter ‘Z’ Beam Clamp is designed to clip into place on Zed
Purlin Flanges, Multibeam, Zeta beam etc. for supporting sprinkler
pipes etc.
The recommended torque figure when assembling the Z-Beam Clamp is
8 Nm (6 lbf. ft.)
Electro-zinc plated finish
Note: Loads
When fixing to Z-Beam steelwork, any loads carried are subject to the
strength of the steelwork itself.
Note: A ‘Z’ Beam Clamp with a longer
leg is available on request.
Z Beam Clamp
BE228N
GENERAL NOTES
50
y Standard material Carbon Steel 25 x 3.
y Standard finish Zinc Plated.
M10
PERTH
MELBOURNE
BRISBANE
SYDNEY
45
JAKARTA
SINGAPORE
Beam Clamp
BE230
Rod Attachment
BE231
GENERAL NOTES
y
y
y
BE230 allows Drop Rods Dia D M6, M8, M10 or M12 to be suspended from A Beam.
It can be provided with the BE231 Rod attachment.
Standard finish Zinc Plated.
y
WHEN ORDERING, PLEASE SPECIFY DROP ROD DIA D AND TYPE NUMBER (BE230 AND BE231) REQUIRED.
Beam Clamp
BE233
GENERAL NOTES
y
y
y
Standard material 90 x 6.
Standard finish Zinc Plated.
BE233 Beam Clamp fits B1000 and B2000 Binder Channels.
PERTH
MELBOURNE
BRISBANE
SYDNEY
46
JAKARTA
SINGAPORE
Beam Clamp
BE234
GENERAL NOTES
y
y
y
Standard material 32 x 6.
Standard finish Zinc Plated.
BE234 should be used in pairs as drawn to Clamp B1000,
B2000, B3300 and B4000 Binder Channels to a beam.
Beam Clamp
BE235
GENERAL NOTES
y
y
Standard material 40 x 6.
Standard finish Zinc Plated.
Beam Clamp
BE236
GENERAL NOTES
y
BE236 Beam Clamps are supplied in pairs and are
suitable for B1000 and B2000 or B3300 and
B4000 Binder Channels.
y
Standard finish Zinc Plated.
Beam Clamp
BE237
GENERAL NOTES
y
y
y
y
Standard material 75 x 6.
Standard finish Hot Dip Galvanised.
M10 U-Bolt included with Clamp.
Clamp fits B1000, B2000, B3300 and B4000 Binder Channels.
WHEN ORDERING PLEASE SPECIFY CHANNEL TO BE CLAMPED
PERTH
MELBOURNE
BRISBANE
SYDNEY
47
JAKARTA
SINGAPORE
Slotted Angle
ANGLE SIZE
SLOT WIDTH D
40 x 40 x 3
8
40 x 40 x 3
11
40 x 40 x 5
8
40 x 40 x 5
11
BE240
GENERAL NOTES
y BE240 Slotted Angle is available in 40 x 40 x 3 or 40 x 40 x 5 Angle.
y Standard length 3750mm although other lengths up to 7500 are available on request.
y Standard finish Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY ANGLE SIZE AND SLOT WIDTH
SLOTTED FLAT BAR IS AVAILABLE IN 6 METRE LENGTHS,
40 WIDE BY 5 THICK OR EITHER 8mm OR 11mm SLOTS.
Medium Duty Cantilever
BE241
ANGLE
SIZE
A
B
C
HOLE
D
HOLE
E
F
G
40 x 40 x 5
300
200
50
11
See Note 1
See Note 2
See Note 2
40 x 40 x 5
450
350
50
11
See Note 1
See Note 2
See Note 2
50 x 50 x 6
600
450
75
14
See Note 1
See Note 2
See Note 2
50 x 50 x 8
750
600
75
18
See Note 1
See Note 2
See Note 2
75 x 75 x 10
900
700
100
22
See Note 1
See Note 2
See Note 2
GENERAL NOTES
y
y
y
y
y
Note 1: Hole Dia E to be specified.
Note 2: Dimensions F and G to be specified.
The above dimensions are a guide only.
All lengths can be varied to suit site conditions.
Standard finish Hot Dip Galvanised.
y WHEN ORDERING, PLEASE SPECIFY DIMENSIONS REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
48
JAKARTA
SINGAPORE
Cantilever
Cantilever
B2513 to B2516
REF.
B2513A to B2516A
LENGTH
DESIGN LOAD
L
UNIFORMLY DISTRIBUTED
CONCENTRATED END LOAD
B2513(A)
150
540kg
180kg
B2514(A)
300
270kg
90kg
B2515(A)
450
180kg
72kg
B2516(A)
600
135kg
45kg
GENERAL NOTES
y
y
y
y
y
When Cantilevers are installed in the inverted position, load rating should be reduced by 40%.
Back plate material 40 x 6.
Fixing hole 14 dia to suit M12 fixing.
Standard finish Hot Dip Galvanised.
Factor of safety 2.50.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
Cantilever
REF.
B2663
LENGTH
DESIGN LOAD
L
UNIFORMLY DISTRIBUTED
CONCENTRATED END LOAD
B2663A
150
815kg
270kg
B2663B
300
450kg
135kg
B2663C
450
315kg
90kg
B2663D
600
225kg
68kg
GENERAL NOTES
y
y
y
y
Back plate material 50 x 8.
Fixing hole 14 dia to suitM12 fixing.
Standard finish Hot Dip Galvanised.
Factor of safety 2.50.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
49
JAKARTA
SINGAPORE
Cantilever
B2700 to 2703
LENGTH
REF.
A
L
BASE PLATE
DESIGN LOAD
MATERIAL
UNIFORMLY DISTRIBUTED
CONCENTRATED END LOAD
B2700
320
165
50 x 6
1120kg
280kg
B2701
470
165
50 x 6
800kg
200kg
B2702
635
215
50 x 10
750kg
180kg
B2703
780
215
50 x 10
600kg
150kg
GENERAL NOTES
y Standard finish Hot Dip Galvanised.
y Fixing holes 14 dia to suit M12 fixings.
y Factor of safety 2.50.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
Cantilever
REF.
B1075A and B1075B
LENGTH
L
B1075A
120
B1075B
205
GENERAL NOTES
y
y
y
y
B1075 suits B1000, B2000, B3300 and B4000 Binder Channels.
Standard material 40 x 6.
Standard finish Hot Dip Galvanised.
Fixing holes 14 dia to suit M12 fixings.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
50
JAKARTA
SINGAPORE
Standard Binder Channels
B1000 Series Channels
B1001
B1002
B1003
B1004
GENERAL NOTES
y
y
y
y
B1000 Series Channels are rolled in 2.5mm thick steel.
Channel weights: B1000 2.63kg/m: B1001, B1002, B1003 and B1004 5.26kg/m.
Standard finishes: Hot Dip Galvanised - Galvabond - Black.
Standard length: 6.0m. Other lengths available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL TYPE AND FINISH REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
51
JAKARTA
SINGAPORE
B2000 Series Channels
GENERAL NOTES
y
y
y
y
B2000 Series Channels are rolled in 1.6mm thick steel.
Channel weights: B2000 1.85kg/m: B2001 3.70kg/m.
Standard finishes: Hot Dip Galvanised - Galvabond - Black.
Standard length: 6.0m. Other lengths available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL TYPE AND FINISH REQUIRED.
B3300 Series Channels
GENERAL NOTES
y
y
y
y
B3300 Series Channels are rolled in 2.5mm thick steel.
Channel weights: B3300 1.90kg/m: B3301 3.80kg/m.
Standard finishes: Hot Dip Galvanised - Black.
Standard length: 6.0m. Other lengths available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL TYPE AND FINISH REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
52
JAKARTA
SINGAPORE
B4000 Series Channels
GENERAL NOTES
y
y
y
y
B4000 Series Channels are rolled in 1.6mm thick steel.
Channel weights: B4000 1.30kg/m: B4001 2.60kg/m.
Standard finishes: Hot Dip Galvanised - Galvabond - Black.
Standard length: 6.0m. Other lengths available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL TYPE AND FINISH REQUIRED.
B5500 Series Channels
B5500
B5501
GENERAL NOTES
y
y
y
y
B5500 Series Channels are rolled in 2.5mm thick steel.
Channel weights: B5500 3.45kg/m: B5501 6.90kg/m.
Standard finishes: Hot Dip Galvanised - Black.
Standard length: 6.0m. Other lengths available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL TYPE AND FINISH REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
53
JAKARTA
SINGAPORE
Concrete Insert Series Channels
B1000 C.I.
GENERAL NOTES
y B1000 C.I. Channel Inserts are used for casting into a concrete slab. The Channel
is factory foam filled to avoid the concrete filling the Channel spaces. After the pour the
foam is easily removed using a screwdriver.
y Standard finish Hot Dip Galvanised.
y Standard length: 6.0m. Other lengths in modules of 200mm (i.e. 200mm long, 400mm long,
600mm long etc.) available on request.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL REFERENCE AND LENGTHS REQUIRED.
Binder Channel Nut Fasteners
y Suitable for B1000 and B2000 Series Channels
REF.
THREAD DIA
B1006
M6
B1007
M8
B1008
M10
B1010
M12
B1012
M16
y
Suitable for B3300 and B4000 Series Channels
LONG SPRING
REF.
THREAD DIA
B4006
M6
B4007
M8
B4008
M10
B4010
M12
B4012
M16
REF.
THREAD DIA
B3016
M6
y Suitable for all Binder Channels - B1000, B2000, B3300, B4000, B5500
REF.
THREAD DIA
B3006
M6
B3007
M8
B3008
M10
B3010
M12
B3012
M16
GENERAL NOTES
y Standard finish Zinc Plated.
y Note: All Channel Nuts are available Tapped Imperial B.S.W.
y WHEN ORDERING, PLEASE SPECIFY CHANNEL NUT REFERENCE REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
54
JAKARTA
SINGAPORE
SHORT SPRING
B2024 Series Two Piece Channel Clip
REF.
CLAMP
DIA D
CLAMP
DIA D
REF.
REF.
CLAMP
DIA D
CLAMP
DIA D
REF.
B2024
8
B2036
44
B2051
92
B2067
143
B2025
11
B1115
48
B2052
95
B2068
146
B2026
14
B2037
49
B2053
98
B2069
149
B2027
17
B2038
51
B1120
102
B2070
152
B1109
18
B2039
54
B2055
105
B2070-62
159
B2028
19
B2040
57
B2056
108
B2070-64
165
B1111
21
B1117
60
B2057
111
B2070-66
171
B2029
22
B2042
64
B1121
114
B2070-70
178
B2030
25
B2043
67
B2059
117
B2070-72
184
B1112
27
B2044
70
B2060
121
B2070-74
191
B2031
29
B1118
73
B2061
123
B2070-76
197
B2032
32
B2046
76
B2062
127
B2070-80
203
B1113
34
B2047
79
B2063
130
B2070-84
216
B2033
35
B2048
83
B2064
133
B2070-90
232
B2034
38
B2049
86
B2065
136
B2070-100
252
B1114
42
B1119
90
B2066
140
B2070-110
315
GENERAL NOTES
y
y
y
y
Binder 2024 Series Clip fits all Binder Channels.
Standard finish Zinc Plated.
Available plastic coated for copper tube on request
Available in stainless steel on request.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
B3024 Series One Piece Channel Clip
REF.
CLAMP
DIA D
REF.
CLAMP
DIA D
B3024
13
B3035
64
B3025
19
B3036
76
B3026
21
B3037
89
B3027
25
B3038
102
B3028
27
B3039
114
B3029
32
B3040
127
B3030
38
B3041
140
B3031
43
B3042
152
B3032
48
B3043
165
B3033
51
B3044
168
B3034
60
B3045
202
GENERAL NOTES
y
y
y
y
Binder 3024 Series Clip fits all Binder Channels.
Standard finish Zinc Plated.
Available plastic coated for copper tube on request.
Available in stainless steel on request.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
55
JAKARTA
SINGAPORE
B2600 Isolation Barrier
GENERAL NOTES
y B2600 when wrapped around copper tube forms an
effective barrier between tube and steel.
y Available in lengths up to 30m.
y WHEN ORDERING, PLEASE SPECIFY LENGTH REQUIRED.
Binsulclamp
BE3500
PIPE OD
ins
PIPE OD
mm
A
mm
B
mm
1/4
3/8
1/2
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
6.35
9.53
12.70
15.88
19.05
22.23
28.58
34.93
42.75
53.98
66.68
79.38
92.08
104.78
31.75
34.93
38.10
42.75
44.45
49.21
53.98
60.33
73.03
88.90
101.60
114.30
127.00
139.70
15.88
19.05
23.81
25.40
30.16
33.34
36.51
44.45
53.98
68.26
80.96
93.66
133.35
146.05
GENERAL NOTES
y Insulates against heat loss and reduces vibration.
y Plastic inserts are designed to withstand temperatures between -30°C and 125°C
y Metal parts are Zinc Plated and colour passivated.
PERTH
MELBOURNE
BRISBANE
SYDNEY
56
JAKARTA
SINGAPORE
Flat Channel Fittings
GENERAL NOTES
y
y
y
y
Standard Material Thickness 6mm.
Standard finish Zinc Plated/Hot Dip Galvanised.
Unless specified holes 14 Dia to suit M12 Fixings.
Fittings suit all Binder Channels.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
57
JAKARTA
SINGAPORE
90° Channel Fittings
REF
B1026
B1068
A
48
57
B
51
41
REF
B1326
B1346
B1458
A
105
98
89
B
45
48
57
GENERAL NOTES
y
y
y
y
Standard Material Thickness 6mm.
Standard finish ZincPlated/Hot Dip Galvanised.
Holes 14 Dia to suit M12 Fixings.
Fittings suit all Binder Channels.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
58
JAKARTA
SINGAPORE
Z Channel Fittings
GENERAL NOTES
y
y
y
y
y
y
B4045 suitable for B3300 and B4000 Binder Channels.
B1045 suitable for B1000 and B2000 Binder Channels.
B5545 suitable for B5500 Binder Channels.
Standard Material 40 x 6.
Standard finish Zinc Plated/Hot Dip Galvanised.
Holes 14 Dia to suit M12 Fixings.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
U Channel Fittings
GENERAL NOTES
y Standard Material 40 x 6.
y Standard finish Zinc Plated/Hot Dip Galvanised.
y Holes 14 Dia to suit M12 Fixings.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
REF
B1047
B4047
B5547
PERTH
MELBOURNE
BRISBANE
SYDNEY
59
JAKARTA
CHANNEL TO BE CLAMPED
B1000 and B2000
B3300 and B4000
B5500
SINGAPORE
Angular Channel Fittings
REF.
ANGLE
Ao
B1186
45o
B2108
60o
B2106
75o
REF.
ANGLE
REF.
Bo
ANGLE
Co
B2103
15o
B1546
45o
B2101
30o
B2097
60o
B2095
75o
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
Angle Brace
B2452
GENERAL NOTES
y Standard material 40 x 6.
y Standard finish Zinc Plated/Hot Dip Galvanised.
y Holes 14 dia to suit M12 fixings.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
60
JAKARTA
SINGAPORE
Channel Base Fittings
B2072B
B2072A
B2073
GENERAL NOTES
y Standard finish Hot Dip Galvanised.
y See DWG to determine hole sizes - 14 DIA for M12, 18 DIA for M16.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
PERTH
MELBOURNE
BRISBANE
SYDNEY
61
JAKARTA
SINGAPORE
Plastic Channel Fittings
B1184/PL PVC CLOSURE STRIP (3.0m LENGTHS)
PLASTIC END CAPS
B2407 FOR B1000
B2280 FOR B2000
B3380 FOR B3300
B4407 FOR B4000
B5580 FOR B5500
GENERAL NOTES
y B1184/PL suitable for all binder channels.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
Electric Light Fittings
GENERAL NOTES
y Standard Material 40 x 1.6.
y Standard finish Zinc Plated.
y WHEN ORDERING, PLEASE SPECIFY REFERENCE NUMBER REQUIRED.
BE300 Series Cable Clamp
Installed Position
GENERAL NOTES
y BE300 is designed to be epoxy glued to soffit/ceiling structure.
y 35-3mm dia holes allow epoxy to rigidly fit clamp to soffit.
y When epoxy is dry, two clamp tabs are twisted over as shown, clamping
cable into desired position.
y Standard material 0.8mm galvabond steel.
PERTH
MELBOURNE
BRISBANE
SYDNEY
62
JAKARTA
SINGAPORE
100% DEZINCIFICATION RESISTANT
PERTH
MELBOURNE
BRISBANE
64
SYDNEY
JAKARTA
SINGAPORE
TWINLOK TEST PLUGS
ALWAYS INSIST ON TWINLOK® TEST PLUGS
YOUR ABSOLUTE GUARANTEE
OF LEAK PROOF PLUGS
Available Units
Several bodies and cores can be supplied to be impervious to various
liquids and gases.
A Brass body with a NORDEL Core for all water based applications.
A Stainless Steel or brass body with a NEOPRENE Core for HydroCarbon applications.
A Stainless Steel Body with NORDEL or NEOPRENE Core for Food and
Process Applications.
Twinlok Test Plug
Applications
Safety
This unique core design ensured efficient sealing. No leakage or jetting
on withdrawal of instrument probes.
Twinlok Test Plug Applications
1) Heating Systems
a) Static Pressure Measurement.
b) Temperature Measurement.
c) Differential Pressure Measurement.
a) This applies to pump pressures, tank head pressures and branch
line pressures up to 3500 Kpa.
b) Feeder line temperature i.e. boiler supply temperature (Flow and
Return), Branch line (F & R) Temperature difference across
heating coils or fan/coil units. Temperature not exceeding
135oC.
c) Differential pressure for determining water flow rates. These are
used as access points on Orifice Plates, Heating Coils, Double
Regulating valves. Used in conjunction with a Mercury
Manometer(inclined or vertical) Differential pressure gauge or
Perfector Flow Computer.
When to use the Twinlok Test Plug
The principle of the Twinlok Test Plug is to provide a Self Sealing access
point in live liquid or gas pipes so that pressure and temperature
measurements may be made within the pipe. It replaces the old method
of fixing a permanent instrument in the pipework whether it be for
temperature or pressure measurement. Max. Pressure 3500 Kpa, Max.
Temperature 130oC.
Advantages
Cost
On a straightforward cost comparison the Test Plug replaces a pressure
gauge and gauge cock. The provision of a line fixing has to be provided
in both cases. The gauge cock is generally more expensive than the Test
Plug and even a very cheap gauge would be more expensive than a single
Test Plug.
So that one may measure temperature at the same point a cheap
Thermometer could be permanently installed. This would mean two
insertions in the pipe with a greater chance of leakage. The Test Plug
provides a single entry point.
Location of Test Plugs related to above
a) Immediately either side of the pump. On many centrifugal
pumps a ¼” BSP tapping is available on the input and output. At
any convenient point upstream and downstream of the pump. In
the pipeline at the lowest feeding point from the tank. At the feed
and end points of the branch line or wherever required. The point
of a fan/coil unit could be used.
b) At any convenient point where design information is required or
where commissioning information is necessary for balancing the
heating system i.e. at the same points where the pressure
readings are taken. Advantage:- Pressure and Temperature
readings at one point. Two fixed instruments normally required
(T & P).
c) When it is necessary to determine water flow rates or pressure
differentials across heating coils etc, the Test Plug gives
immediate access for any type of differential measuring device.
Orifice Plate:
Stainless Steel Orifice Plate to BS 1042 mounted in a
polypropelene on metal carrier complete with corner tappings
which are connected to two Test Plugs from which can be taken
the H.P. & L.P. pressure readings.
Heating Coils:
Test Plugs on the supply and return headers help to provide
differential pressure readings. Knowing the coil resistance the flow
can be calculated.
Double Regulating Valves:
This is a common method of measuring flow rates when using
the calibrated valve orifice and differential pressure across the
orifice as a means of obtaining volumetric flow rates. A test plug
is screwed into each of the ¼” BSP tappings either side of the
valve and differential pressure readings taken. The flow rate is
calculated from the valve characteristic curves supplied.
Accuracy
By using the Pressure Gauge Adaptor Probe a much higher grade
instrument may be used in an infinite number of positions. If a low grade
instrument is selected it can be used to greater accuracy because of the
common datum of measurement. This also applies to temperature
measurement.
When using the temperature gauge with a pocket inserted in the line,
inaccuracies occur due to bad contact between the temperature sensor
and the liquid in the pipe, i.e. the pocket is the intermediate conductor.
This does not occur when using a Test Plug as the sensor is in intimate
contact with the liquid to be measured, this also applies to gases.
Location
The positioning of Test Plugs in the line is often very simple, particularly
where isolating or Double Regulating Valves are installed. Most of these
are fitted with ¼” B.S.P. tapped bosses upstream and downstream of the
valve into which can be screwed ¼” B.S.P.T. Test Plugs. In this position
they can be used for Measuring Pressure, (i.e. balancing the system when
cold) Temperature (i.e. checking system when hot MAX 135oC) & flow
measurement. (i.e. measuring pressure differential which is used in
conjunction with the valve characteristic to determine flow velocities and
hence volumetric flow). This measurement can be made with a Differential
Pressure Gauge, Manometer or Perfector Flow Computer.
Time Savings
Speed of operation is probably the greatest advantage of the Test Plug.
When using a pressure gauge and adaptor it is just a question of removing
the dust cap and pushing the adaptor through the plug. This gives an
instant line pressure reading. Withdraw the probe and replace dust cap.
Temperature readings are made in the same way.
No instruments are left in position to be damaged on purpose or by
accident.
This is an advantage in housing situations or district heating schemes
where instruments could be vandalised.
Whenever the pressure probe or temperature probe is pushed through
the Test Plug and withdrawn the wiping process automatically keeps the
probe and the internal parts of the core clean. When permanent
instruments are installed, a mineral deposit is built up around the sensor
thus blocking the cavity or reducing sensitivity. The ball type seating for
pressure measurement only can be held open due to solids in the seating.
2) Chilled Water System
The same principles apply to chilled water systems as to heating
systems except that greater accuracy is called for due to the small
percentage error allowable on the recorded temperature, which is
normally 7oC to 13oC. By using the Test Plug a larger number of
readings can be taken at low capital cost.
3) Dezincification
a) The Twinlok Test Plug is manufactured from a Dezincification
resistant Brass Alloy. This is particularly important in several
Australian States where the water quality causes rapid
deterioration of conventional Brass Leaching the zinc from the
alloy and causing brittle failure in a short period of time.
b) Tests have been conducted on the Twinlok by the Engineering
Research Station (PWD) Western Australia to A52345 - 1980 for
conformance of the Dezincification.
c) Engineering Research Station conducted Pressure Tests on the
Twinlok up to 8000 KPA for prolonged periods. AS1590 - 1982
requires pressures of 2000 KPA at 15 seconds which the
Twinlok greatly exceeded. Copies of Test Certificates are
available on request.
End Users
A large proportion of Test Plugs are sold to the Heating, Ventilating and
Air Conditioning industry for applications as described. The plug can also
be used for sampling liquids, semi-solids and gases in the Process, Food
and Petro-Chemical Industries. It can also be used for injecting in the
same way. Pump rates etc. can be checked by fitting either side i.e. suction
and discharge. There are many O.E.M. applications such as either side
of fan/coil units, chilled water coils, pumps, hydraulic lines and
compressors etc. Injecting oil or similar into gearboxes is just another
application.
PERTH
MELBOURNE
BRISBANE
SYDNEY
65
JAKARTA
SINGAPORE
Twinlok Test Plug Installation
Weld a ¼” BSP socket to the outside of the pipe and
drill a hole 6mm diameter through the pipe wall at the
centre of the socket.
Prepare Test Plug with sealing media - PTFE tape etc.
Screw Twinlok Test Plug into socket.
Remove protective cap and the Test Plug is ready to
accept the measuring instrument
Pressure Guage complete with adaptor probe inserted
in Test Plug.
Dial Test Thermometer inserted in
Test Plug.
LUBRICATE PROBES WITH SILICONE OIL
PERTH
MELBOURNE
BRISBANE
SYDNEY
66
JAKARTA
SINGAPORE
Twinlok Test Plug Chemical Resistance
Chemical Resistance of Nordel Core
Material
To assist engineers in determining the suitability
of the elastomer core material for their particular
application the accompanying list* has been
prepared. It is emphasized that this is a guide
only. The tabulation is based on laboratory tests
and records of actual service performance. The
Acetaldehyde
Acetic acid, 20%
Acetic acid, 30%
Acetic acid, glacial
Acetic anhydride
Acetone
Acetylene
Aluminium chloride solutions
Aluminium sulphate solutions
Ammonium chloride solutions
Ammonium hydroxide solutions
Ammonium sulphate solutions
Amyl acetate
Amyl alcohol
Aniline
Barium hydroxide solutions
Beer
Benzaldehyde
Borax solutions
Boric acid solutions
Butane
Butyl acetate
Butyraldehyde
Calcium chloride solutions
Calcium hydroxide solutions
Calcium hypochlorite, 5%
Calcium hypochlorite, 20%
Castor oil
Chlorine gas, dry
Chlorine gas, wet
Chloroacetic acid
Citric acid solutions
Copper chloride solutions
Copper sulphate solutions
Cottonseed oil
Dibutyl phthalate
Diethyl sebacate
Dioctly phthalate
Epichlorohydrin
Ethyl acetate
degree of compatability with a particular fluid
depends on such variables as temperature,
aeration, velocity of flow, duration of exposure,
stability of fluid, degree of contact etc. It there is
any uncertainty as to compatability, then tests
should be carried out prior to specification.
Ethyl acetate
Ethyl alcohol
Ethyl chloride
Ethylene dichloride
Ethylene glycol
Ferric chloride solutions
Formaldehyde, 40%
Formic acid
FREON-12
Furfural
Glycerin
Hydrazine
Hydrochloric acid, 37%
Hydrocyanic acid
Hydrofluoric acid, 48%
Hydrogen
Hydrogen sulphide
Lactic acid
Linseed oil
Magnesium chloride solutions
Magnesium hydroxide solutions
Mercuric chloride solutions
Mercury
Methyl alcohol
Methyl ethyl ketone
Methylene chloride
Nitric acid, 10%
Nitric acid, 30%
Nitrobenzene
Oleic acid
Palmitic acid
Phenol
Phosphoric acid, 20%
Phosphoric acid, 60%
Phosphoric acid, 70%
Phosphoric acid, 85%
Picric acid
Potassium dichromate solution
Potassium hydroxide solutions
Pyidine
Sea water
Silicone grease
SKYDROL 500
Soap solutions
Sodium chloride solutions
Sodium dichromate, 20%
Sodium hydroxide, 20%
Sodium hydroxide, 46½%
Sodium hydroxide, 50%
Sodium hydroxide, 73%
Sodium hypochlorite, 5%
Sodium hypochlorite, 20%
Sodium peroxide solutions
Stannous chloride, 15%
Steam (see water)
Stearic acid
Sulphur, molten
Sulphur dioxide, liquid
Sulphur dioxide, gas
Sulphur trioxide
Sulphuric acid, up to 5%
Sulphuric acid, 5-10%
Sulphuric acid, 10-50%
Sulphuric acid, 95%
Tannic acid, 10%
Tartaric acid
Tricresyl phosphate
Triethanolamine
Trisodium phosphate solutions
Water
Zinc chloride solutions
NORDEL is a proprietary material and the information presented is believed to be accurate and reliable.
Binder Engineering Co. Ltd. can assume no liability for results obtained or damage incurred through the
application of the data. The information is intended as a guide, if in doubt - ask!
ALWAYS INSIST ON TWINLOK® TEST PLUGS
YOUR ABSOLUTE GUARANTEE
OF LEAK PROOF PLUGS
100% DEZINCIFICATION RESISTANT
PERTH
MELBOURNE
BRISBANE
SYDNEY
67
JAKARTA
SINGAPORE
Twinlok Test Plug
Operating Instructions and
Safety Precautions
Standard
Test Plug
Extension
Piece (50mm)
Specification
Brass or 316SS Body/Nordel Cores
Temperature Range
Continuous
operation
-10°C to 135°C
(14°F to 275°F)
Maximum
intermittent
operation
135°C
(275°F)
Maximum
intermittent
pressure
3500 Kpa
(500 PSI)
Thread ¼” NPT available from stock upon request
Operating Procedure- Pressure and
Temperature Readings
1. The operator should wear protective clothing
i.e. gloves and goggles when using the plug in
high temperature lines or where any injurious
liquids or gases are contained.
2. Slowly remove the cap from the plug. If, while
doing, you feel or hear gas or liquids escaping
quickly retighten the cap. Determine at this
time if the plug has been used improperly and
if necessary replace the plug as soon as
possible.
3. Having determined that the plug is operating
correctly, remove the cap.
4. Select the appropriate probe for pressure and
temperature. Clean and lubricate the probe
with a small amount of silicone oil. Examine
the probe for any sharp burrs which could cut
the valves. Remove any burrs before using.
Do not use non-standard or damaged probes.
5. Pressure Probe Insertion:
A. Determine approximate pressure in pipeline
and select a gauge of suitable range complete
with Test Plug adaptor/probe.
B. Partially insert the lubricated pressure probe
into the test plug. If you are not sure of the
pressure behind the plug, be prepared to
quickly withdraw the probe before rupturing or
overpressuring the gauge. The plug, in its
static state and without a cap, can easily
withstand over 500 psig without leaking. Do
not assume that, since the plug is not leaking,
PERTH
MELBOURNE
BRISBANE
C.
D.
E.
F.
6.
A.
7.
SYDNEY
68
that it is safe to quickly and fully insert a lowrange gauge. If you guess wrong, the
pressure gauge could explode in your hand.
When the pressure gauge needle stops
moving up-scale, then fully insert the probe
and read the pressure.
Do not leave the probe in the plug any longer
than necessary. Always screw the
adaptor/probe union to the top of the Test Plug
to prevent the internal pressure from ejecting
the instrument and probe.
When removing the probe, do not place your
face near the plug. The plug should not leak
when you remove the probe, but always
observe safety precautions.
As soon as the probe is removed, replace the
cap.
Temperature Probe Insertion:
Temperature probe insertion is similar to
pressure probe insertion with the exception
that the operator should always first determine
the pressure behind the plug before insertion
of the temperature probe. This establishes
that the plug is operating within its
specification limits. After pressure has been
determined, follow the steps as outlined in
items 5A to 5F.
Using a test plug which has been installed
and unused for several years.
Follow all operating procedures shown above.
JAKARTA
SINGAPORE
Pressure Gauges
General Purpose Type Pressure Gauge
B100
Application
Measurement of positive and negative pressures in
the range up to 400 bar maximum.
(35 bar when used with Twinlok Test Plugs).
Technical characteristics
Accuracy
±1.6% of full scale deflection
Temperature range
-25 to +60°C
Ambient temperature
soldered gauge +60°C
Fluid temperature
welded gauge
+100°C
Special designs for temperatures up to 200°C max.
Standard Dial Sizes
63mm Dial ¼” B.S.P. Connection.
100mm Dial 3/8” B.S.P. Connection.
Other sizes available on request.
3/8”-¼” B.S.P. Reducers available.
NOTE:- All 63mm dia. gauges supplied with
calibration of Kpa.
Gauges are available in PSI and Bar upon reuqest.
Temperature coefficient of indication
(reference temperature +20°C)
Deviation of indication per 10°C about +0.3% of
indicated value for higher temperatures, about -0.3%
of indicated value for lower temperatures.
The temperature used for the correction of the
indication is the temperature of the measuring system,
not the temperature of the fluid under pressure.
Standard Calibrations
0-200 Kpa
0-400 Kpa
0-600 Kpa
0-800 Kpa
0-1000 Kpa
0-1600 Kpa
0-2000 Kpa
Permissible range
Upper limit for static load: ¾ of full scale deflection.
For fluctuating load: 2/3 of full scale deflection. Shorttime peaks up to full scale deflection.
N.B.
Pressure Gauge adaptor required when using gauge
with Twinlok Test Plugs (see below).
Glycerine filled Gauges are also available to counter
vibration.
General Gauge Adaptor
B180
Dimensions A = ¼” B.S.P.
B = 35mm
C = 35mm
PERTH
MELBOURNE
BRISBANE
SYDNEY
69
JAKARTA
SINGAPORE
Thermometers
Dial Test Thermometer
C100
Dimensions:
Dial Dia. 45mm.
Stem Length 110mm.
Stem Diameter 4mm.
Bimetallic Element
Accuracy
± 1% F.S.D.
Standard Temperature Ranges:
-30
+70°C.
-10
+110°C.
0
+200°C.
Note:- Suitable for use with ¼” B.S.P. Twinlok Test Plug.
Digital Stem Thermometer
C100D
Dimensions:
Range:
38mm Dia.
Stem Length 120mm.
Stem Diameter 3mm.
-10 +110°C
Surface Contact Thermometer
C120
Dimensions:
Dial 70mm.
Suitable for 25NB and
150NB pipes.
Accuracy
± 1% F.S.D.
Standard Temperature Ranges:
0
-120°C.
0
-200°C.
-35
+55°C.
Note:To improve the thermal contact between the surface to be measured and the
contact base of the thermometer we recommend the use of a heat conducting
grease.
PERTH
MELBOURNE
BRISBANE
SYDNEY
70
JAKARTA
SINGAPORE
Differential Digital Thermometer
C200
Digital portable differential
thermometer for measuring
single point, two point and
difference temperatures.
Specification
Range
-50 to +450°C.
Resolution
1°C.
Accuracy
0.5% reading ±1°C.
Display
3 digit LCD 13mm character height.
Controls
3 position switch for T1/T2/T1-2, plus
ON/OFF switch.
Probes
T1 and T2. 130mm long below handle. 3mm
diameter connected to 1m extensible cord
wander leads.
Application
single point, two point and differential
temperature measurement for surface liquid
and air/gas.
Battery
single 9 volt Ever Ready/Berec PP3-P or
equivalent. Access via rear sliding cover.
Battery Life
200 hours (1 year of normal use). Change
battery on check indication.
Size
140 x 80 x 30mm.
Weight
350 grams.
Guarantee Period
12 months.
PERTH
MELBOURNE
BRISBANE
SYDNEY
71
JAKARTA
SINGAPORE
Pervu Water Flow Portable Test Sets
D200
Designed for Commissioning of Building Services by balancing & regulating the flow of heating and
chilled water systems, as specified in Department of the Environment Property Services Agency M & E No.
3; Chartered Institute of Building Services Commissioning Code W; and Building Services Information and
Research Association application guide 1/79 - Manual for Regulating Water Systems.
In the Water Industry these sets enable the site engineer to calibrate differential pressure instruments.
FEATURES
Fundamental principles ensure accuracy
and reliability.
Purpose designed instrument and valve
manifold.
Clear parallax-free reading.
Strong marine ply carrying case practical for
site work.
The sets measure Differential Pressure, and
thus related Rate of Flow, across :Commissioning Sets, Balancing & Orifice
Valves, Metering Stations, & Venturis.
Double Regulating and Three port Valves
Pumps, Chiller Units and Heater Batteries.
Orifice Plates, Dall and Pitot tubes.
VERSIONS
‘Stock’ ranges are genuinely available for
immediate delivery. Further sizes are
assembled and tested within days. Versions for
High Pressure Hot Water at full line pressure
and temperature are despatched in 2-3 weeks.
Specification
Solid Perspex Precision Bore Manometer.
Specially designed by-pass and isolating 3valve manifold.
Two 3-metre lengths of tubing fitted with quickconnect self-seal couplings.
Adaptors for all types of test plugs and pressure
tappings instantly interchangeable. Marine ply
wooden case with handle and hinged lid,
finished in polyurethane lacquer.
STOCK DUAL RANGE SET
Description
Range
Dual range comprising
0-4.6kPa/
a sensitive low-loss
0-65kPa
manometer and high
or
range mercury
0-470mm H2O/
manometer combined
0-6m H2O
in one carrying case.
or
Scale lengths 500mm
0-18” w.g./
0-20ft head
Order Code
PK50Wx2/kPa
Scale length 1000mm
Inclined manometer
test set. Small and
lightweight
Mercury Filled
0-8 kPa
0-800mm H2O
0-31” w.g.
STOCK ‘LOW-LOSS’ SET
Description
Range
Filled inert liquid
0-4.6kPa or
S.G. 1.88
0-470mm H2O
Scale length 500mm
or 0-18” w.g.
Order Code
PK50W/range
PK50Wx2/mm
Stock Mercury Set
PK50Wx2/in.
Sets For High Velocity on Low-Loss Valves
Description
Range
Order code
Scale length 750mm
0-6.5 kPa
PK75W/B10/
Filled inert liquid
0-680mm H2O
S.G. 1.88
0-26” w.g.
range
0-8.5 kPa
0-900mm H2O
0-35” w.g.
STANDARD VERSIONS
Pressure rating: 10 bar
Temperature:
Maximum 80°C through
manometer. In normal use,
when no flow occurs through
manometer, tubing and
manifold withstand 120°C.
Scale length 500mm
0-65 kPa or
0-6m H2O or
0-20ft head
PK50W/range
Sets For High-Loss Valves, Pump Heads,
Chiller and Heater Batteries
Description
Range
Order code
0-95 kPa
Scale length 750mm
0-9m H2O
PK75W/B10/
Mercury Filled
0-30ft head
range
Scale length 1060mm
0-120 kPa
0-13m H2O
40ft head
PK100W/B10/
range
Scale length 1500mm
0-195 kPa
0-20m H2O
65ft head
PK150W/B10/
range
Dial gauge test set
diameter 150mm
0-2 bar
0-4 bar
PK15/B35/2bar
PK15/B35/4bar
PK100W/B10/
range
PK21W/B10/
range
VERSIONS FOR HPHW
Pressure rating:
35 bar hydraulic.
Temperature:
Maximum 80°C through manometer. In normal use when no flow occurs through
manometer, hoses and manifold withstand 180°C.
Specification:
3-valve manifold in all stainless steel. Hoses of reinforced rubber with crimped
connections. Manometer block thicker and stronger than standard version.
Add letters/HT to last part of order code e.g. PK50W/KPa/HT.
PERTH
MELBOURNE
BRISBANE
SYDNEY
72
JAKARTA
SINGAPORE
Airflow Test Set - Type
D220
DESCRIPTION
Air Flow Portable Test Set, incorporates a variable angle inclined manometer. The device can
be precisely set to cover a pressure range of 0 to 2500 Pa with a total of four manometer positions.
Air Velocities are displayed on direct reading scales, taking differential pressure from a pitotstatic tube, which is normally provided, clipped within the case. A pressure scale is included for
measurement of static and differential pressures, with a simple multiplication factor applied for
different angles of incline.
Features include easy-zero for different slopes due to adjustable scales, a machined joint with
O-Ring spindle which ensures positive and leakproof changes from one position to another.
Overpressure chambers help reduce liquid loss on accidental overpressurisation.
‘Lifetime’ calibration is assured since there can be no sag or distortion of the precision bore
column in the solid perspex block, and also because the relationship between panel and spirit bubble
is permanent.
The air test set comes complete with a pitot static tube, a T-piece and 2 x 6 metres flexible
tubing, with all equipment contained in a wooden carrying case.
PITOT STATIC TUBE
The pitot static tubes are manufactured in stainless steel and come in sizes from
0.30 to 4.0 metres long. The nose is ellipsoidal in shape which ensures that slight nonalignments within the duct have a minimum effect on accuracy of readings. A direction
pointer indicates that the pitot tube is correctly inserted within the ductwork. Temperatures
up to 800°C for short periods and 700°C for extended use can be admirably withstood.
The above properties of the pitot static tube combined with the versatility of the
variable slope inclined test set provide an ideal method for measuring air and gas flows
from ducted air in the building services industry to flue gases in general industry.
SPECIFICATION
Manometer Body
Indicating liquid
Scale length
Pressure Ranges
position 1
3
: 0-0.5” w.g. or 125 Pa or 12.5mm H2O
: 0-1.0(0.01)” w.g. or 250(1) Pa or 25(0.1)mm H2O
: 0-2.0” w.g. or 500 Pa or 50mm H2O
Vertical
: 0-10” w.g. or 2.5 kPa or 250mm H2O
Velocity scale
position 1
3
Pitot Static Tube
Fittings
Tubing
T-Piece
Adjusting
Spare Fluid
Case (Outside dimensions)
: 0-2, 800 ft/min or 0-14 m/s
: 0-5, 600 ft/min or 0-28 m/s
: Stainless Steel, length 0.48m
: 6mm o.d. push-on connectors
: 2 x 6m PVC tubing, 6mm i.d.
: Nylon
: Levelling adjustment, liquid column adjustment
screw and adjustable scale
VELOCITY
: 25cc
: 51 x 24 x 23 cm
DESCRIPTION
ORDER CODE
Air Flow Test Set with pitot static tube
Air Flow Test Set
PK30/Units* + DT 0.48
PK30/Units*
* Please specify Pa or mm or ins w.g.
Options
1. Mercury in glass thermometer
clamped into the case for measurement
of air temperature. RANGE 0-60°C.
PB80
3. Portable U-gauge for use from T-piece for
quick and easy measurement of static
pressures up to 12” w.g./60 mbar. Comes
complete with plastic case and stand facility
and can be kept in the main carrying case.
PG1
4. Pitot static tubes for velocity measurement
are also available in lengths from 0.30m
up to 4 metres long.
DT/metre length
MELBOURNE
TRUE VELOCITY
T60C
2. An aneroid barometer for measurement
of atmospheric pressure changes
to correct velocity readings. Barometer
covers the range 940 to 1060 mbar
and 27.5 to 31.5” Hg.
PERTH
APPLICATIONS
Measurement of air velocities in rectangular
and circular ducts. General low pressure
measurements from 0-0. 5”wg to 0-10”wg.
Ideal for test laboratories and R & D
Establishments. As specified in CIBS
Commissioning Code ’A’, BSRIA Manual 1/75
and in line with British Standards 1042 Part 2
‘A’ 1973 and BS848 ‘Fan Test Code’.
: Solid Perspex
: Red oil S.G. 0.8
: 30 cm
2 (Divisions in brackets)
FEATURES
TOUGH SOLID PERSPEX MACHINED
SWIVEL JOINT CONSTRUCTION BETWEEN
COLUMN AND RESERVOIR
EASY, FAST ZEROING
PRECISION BORE COLUMN
LIFETIME CALIBRATION
OVER PRESSURE CHAMBER
BRISBANE
SYDNEY
73
JAKARTA
SINGAPORE
Flowmeters for Pipes up to 40mm
D240
Solid perspex variable area
flowmeters for flows up to 40mm
pipe.
FEATURES
SIMPLE GRAVITY PRINCIPLE.
LOW PRESSURE DROP.
NO MECHANICAL JOINTS OR
FRICTION.
PRECISION TAPER BORE.
MONOBLOC CONSTRUCTION.
MINOR
6mm compression rear connections
for surface mounting.
Ball float, 40mm scale.
MIDI
¼” BSP Male rear connections for
surface mounting.
Centre-guided rotor floats 100mm
scale.
MAJOR
½” or ¾” BSP Straight-through
connections on rotatable end blocks
with tapped fixing holes for surface,
recess panel or pipe mounting.
Centre-guided rotor floats.
Body removable without disturbing
pipework.
100mm scale
MAGNUM
1” or 1½” BSP straight-through
connections.
STOCK RANGES
SELECT AIR OR WATER SCALE OR ARBITRARY/0-10
FOR VALVE ADD V TO END OF CODE
Name
Code
Air N.T.P.
Water 20°C
MINOR
FG2N
0.3-3
L/min
2-20
ml/min
FG2T
0.6-6
L/min
20-120
ml/min
FG2S
2-10
L/min
50-300
ml/min
FG3G
5-25
L/min
50-500
ml/min
FG3S
5-35
L/min
100-1000
ml/min
FM5D
1-30
L/min
25-500
ml/min
FM5T
5-50
L/min
100-1200
ml/min
FM5S
10-100
L/min
0.3-3
L/min
FR6P
20-200
L/min
FR6D
30-250
L/min
0.5-5
L/min
1-10
L/min
2-20
L/min
0.3-0.36
L/sec
Dimensions
(Block Size) mm
MIDI
MAJOR
FR6A
FR6S
80-600
FR6S
L/min
MAJOR
FR7H
8-30
L/min
PLUS
FR7J
20-60
L/min
MAGNUM
FT8S
5-60
L/min
FT8H
30-100
L/min
FT8J
60-140
L/min
95 x 25 x 25
200 x 25 x 32
200 x 50 x 50
248 x 50 x 50
260 x 80 x 80
AIR AND GAS:OTHER PRESSURES
MULTIPLY reading by — bar absolute)
To select appropriate flowmeter: DIVIDE required flow by — bar absolute)
(Note: This method is accurate to 5% for temperature -10 - 0 - +40°C. It gives flows “at reference conditions”,
such as NI/min or SCFM, i.e. the volume the compressed air or gas would occupy under atmospheric pressure,
which is normally of most interest to users.)
PERTH
MELBOURNE
BRISBANE
SYDNEY
74
JAKARTA
SINGAPORE
Commissioning Kit
F100
CONTENTS
2 No. B100 Standard Pressure Gauge.
2 No. B180 Pressure Gauge Adaptor Probe.
2 No. C100 Dial Test Thermometer.
1 No. C205 Differential Digital Thermometer.
1 No. 10CC Bottle Silicone Oil.
Please specify ranges required for B100
Pressure Gauges and C100 Dial Test
Thermometers. (Digital Stem Thermometers
can be supplied as an alternative).
Case Dimensions: 34 x 25 x 9cm.
Weight: 1.5kg including instruments.
This commissioning kit has been included in
the range of equipment to form an
indispensable aid to the engineer who needs
to take measurements of temperature and
pressure through Twinlok Test Plugs
wherever they may be fitted.
PERTH
MELBOURNE
BRISBANE
SYDNEY
75
JAKARTA
SINGAPORE
Conversion Tables
Pressure
kilogram
pound force
foot of
inch of
metre of
centimetre
inch of
millimetre
force per
per square
water
water
water
of mercury
mercury
of mercury
square
inch
centimetre
atm
ft H2O
m H2O
cm Hg
1
1.0197
14.5038
0.9869
33.4553
401.463
10.1972
75.0062
29.53
750.062
0.9807
1
14.2233
0.9878
32.8084
393.701
10
73.556
28.959
735.559
0.0689
0.0703
0.0609
2.3067
27.68
0.7031
1.0133
1.0332
14.6959
406.782
10.3323
0.0299
0.0305
0.4335
0.0295
1
0.0025
0.0025
0.0361
0.0025
0.0833
0.0981
0.1000
1.422
0.0968
3.2808
0.0133
0.0136
0.1934
0.0132
0.4461
0.0339
0.0345
0.4911
0.0334
1.133
0.0013
0.0014
0.0193
0.0013
0.446
0.5352
bar
kgf/cm²
lbf/in²
1
1
in H2O
33.889
in Hg
5.1715
mm Hg
2.036
76
51.715
29.9213
760
12
0.3048
2.242
0.8827
1
0.0254
0.1868
0.0734
1
7.3556
2.896
73.356
5.3524
0.136
1
0.3937
10
13.5951
0.3453
2.54
0.0136
0.1
39.3701
22.4198
1.8683
1
25.4
0.0394
1
Velocity
metre per second
foot per second
foot per minute
kilometre per hour
m/s
ft/s
ft/m
km/h
1
3.2808
0.3048
1
0.00508
0.01667
0.2778
0.9113
0.447
1.467
196.848
mile per hour
mile/h
3.6
2.2369
1.097
0.6818
0.01829
0.01136
54.68
1
0.62137
88
1.609
1
60
1
Mass
kilogram
pound
hundredweight
tonne
kg
lb
cwt
t
2.2046
0.0197
0.001
0.00098
0.0011
0.4536
1
0.0089
0.000454
0.000446
0.0005
50.8023
112
1
0.0508
0.05
0.056
1
UK ton
US short ton
sh ton
1000
2204.62
19.6841
1
0.9842
1.1023
1016.05
2240
20
1.0161
1
1.12
2000
17.8571
0.9072
0.8929
1
907.185
Mass Rate of Flow
kilogram per second
kilogram per hour
pound per hour
ton per hour
kg/s
kg/h
lb/h
UK ton/hr
1
3600
7936.64
1
2.2046
0.000984
0.000126
0.4536
1
0.000446
1016.05
0.0116
2240
41.6667
t/d
3.54314
0.000278
0.2822
tonne per day
86.4
0.024
0.0109
1
91.8592
24.3852
0.04101
1
Volumetric Rate of Flow
litre
litre
cubic metre
cubic foot
cubic foot
UK gallon
US gallon
per second
per minute
per hour
per hour
per minute
per minute
per minute
per day
l/s
l/min
m³/h
ft³/h
ft³/m
UK gal/min
US gal/min
US barrel/d
1
0.0167
60
1
0.2778
16.6666
0.0079
0.4719
3.6001
0.06
1
127.136
2.1189
13.1986
15.8508
2.1189
0.3532
0.22
0.2642
35.3147
0.5886
3.6662
4.4029
0.1067
0.1038
0.1247
0.0283
1
60
US barrel
543.456
9.0576
150.956
4.2746
0.4719
28.316
1.699
1
6.2288
7.4805
0.0758
4.546
0.2728
9.6326
0.1605
1
1.201
41.1754
0.0631
3.7853
0.2271
8.0208
0.1337
0.8327
1
34.2857
0.0018
0.1104
0.0066
0.2339
0.0039
0.0243
0.0292
SYDNEY
JAKARTA
PERTH
MELBOURNE
BRISBANE
76
256.475
1
SINGAPORE
BE REF
BE 1300
BE 1310
BE 1320
BE 1330
BE 1335
BE 1350
BE 1355
BE 1360
BE 1365
BE 1370
BE 1375
BE 1380
BE 1390
BE 1395
BE 1400
BE 1405
BE 1410
BE 1500
BE 1525
BE 1530
BE 1535
BE 1540
BE 1545
BE 1550
BE 1555
BE 1570
BE 1505
BE 1510
BE 1515
BE 1520
BE 1560
BE 1580
BE 1585
BE 1586
BE 1590
BE 1591
BE 100
BE 101
BE 102
BE 103
BE 103A
BE 104
BE 105
BE 106
BE 107
BE 107C
BE 108
BE 109
BE 110
BE 111
BE 114
BE 115
BE 116 TYPE A
BE 116 TYPE A
BE 116 TYPE B
BE 116 TYPE B
BE 117
BE 120
BE 133
BE 134
BE 135
BE 136
BE 202
BE 206
PERTH
DESCRIPTION
PAGE
SWING CLIP (WITH M10 BOSS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
DUAL CLIP (WITH M10 BOSS) FOR PLASTIC PIPE . . . . . . . . . . . . . . . . . . . .
18
KWIK CLIP (WITH M10 BOSS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
RISER SUPPORT ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
RISER SUPPORT ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
CLIC CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
CLIC INSERT NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
HAMMER-IN SHOULDER STUD & PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
CLIC DUO WALL PLATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
KWIK CONNECT ROD JOINER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
PIPE SLIDE GUIDE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
M10 HANGER BOLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
NYLON ANCHOR PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
STAR ANCHOR PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
SUSPENSION EYE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
WALL PLATE TYPE A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
WALL PLATE TYPE B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
RAPIDRAIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
RAPIDRAIL CONNECTOR 90° (SHORT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
RAPIDRAIL CONNECTOR 90° (LONG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
RAPIDRAIL CONNECTOR 135° (LONG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
RAPIDRAIL T-CONNECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
RAPIDRAIL X-CONNECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
RAPIDRAIL X-CONNECTOR (TOP HAT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
RAPIDRAIL CONNECTOR 200mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
RAPIDRAIL PROP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
RAPIDRAIL SLIDE NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
HAMMERFIX TEE-BOLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
SWIVEL BALL HANGER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
RAPIDRAIL END PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
RAPIDRAIL CANTILEVER ARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
VIBRATION DAMPER WASHER M10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
DUCT BRACKET TYPE L WITH RUBBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
DUCT BRACKET TYPE L WITHOUT RUBBER . . . . . . . . . . . . . . . . . . . . . . . .
29
DUCT BRACKET TYPE Z WITH RUBBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
DUCT BRACKET TYPE Z WITHOUT RUBBER . . . . . . . . . . . . . . . . . . . . . . . .
29
MEDIUM DUTY 2 BOLT PIPE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
MEDIUM DUTY 2 BOLT PIPE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
LIGHT DUTY PIPE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
ONE PIECE PIPE CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
STAND OFF BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
CLEVIS HANGER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
SADDLE GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
SADDLE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
STANDARD U BOLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
CONDUIT U BOLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
CLEVIS CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
BOSSED CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
STAND OFF CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
TAIL CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
MEDIUM DUTY YOKE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
LIGHT DUTY YOKE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
WOOD BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
CORK BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
WOOD BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
CORK BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
INORGANIC INSULATION BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
STANDARD FILBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
SPUR ROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
ADJUSTABLE ROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
ADJUSTABLE PIPE STAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
ADJUSTABLE PIPE STAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
ALL THREAD ROD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42
HEX CONNECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42
MELBOURNE
BRISBANE
SYDNEY
77
JAKARTA
SINGAPORE
BE REF
DESCRIPTION
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
B
PLATE WASHER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
ANGLE CLEAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
SUSPENSION CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Z BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Z BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
ROD ATTACHMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
BEAM CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46,47
SLOTTED ANGLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
MEDIUM DUTY CANTILEVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
217
218
224
226
227
228
228N
230
231
233,234,235,236,237
240
241
2513,2513A,2516,
2516A,2663
B
2700,2703,1075A,
1075B
B
1000-1004
B
2000,2001
B
3300,3301
B
4000,4001
B
5500,5501
B
1000 C.I.
B
2024
B
3024
B
2600
B
3500
B
1031,1036,1062,1063,
1064,1065,1066,1067,
1358,1360,1941
B
1026,1033,1034,1035,
1037,1038,1068,1325,
1326,1346,1359,1458
B
2484
B
1045,4045,5545
B
1047,4047,5547
B
1186,1546,2095,2097,
2101,2103,2106,2108
B
2452
B
2072A,2072B,2073
B
1184,2280,2407,3380,
4407,5580
B
2335,2539
BE 300
B
B
C
C
C
C
D
D
D
F
100
180
100
100D
120
200
200
220
240
100
PERTH
PAGE
CANTILEVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
CANTILEVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONCRETE INSERT CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TWO PIECE CHANNEL CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ONE PIECE CHANNEL CLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISOLATION BARRIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BINSULCLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
51
52
52
53
53
54
55
55
56
56
FLAT CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
90° CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Z CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
U CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
ANGULAR CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ANGLE BRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
CHANNEL BASE FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
PLASTIC CHANNEL FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRIC LIGHT FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERIES CABLE CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TWINLOK TEST PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL PURPOSE TYPE PRESSURE GAUGE . . . . . . . . . . . . . .
PRESSURE GAUGE ADAPTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIAL TEST THERMOMETER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIGITAL STEM THERMOMETER . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SURFACE CONTACT THERMOMETER . . . . . . . . . . . . . . . . . . . . . . .
DIFFERENTIAL DIGITAL THERMOMETER . . . . . . . . . . . . . . . . . . . .
PERVU WATER FLOW PORTABLE TEST SETS . . . . . . . . . . . . . . . .
AIRFLOW TEST SET - TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FLOWMETERS FOR PIPES UP TO 40mm . . . . . . . . . . . . . . . . . . . .
COMMISSIONING KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MELBOURNE
BRISBANE
SYDNEY
78
JAKARTA
SINGAPORE
62
62
62
68
69
69
70
70
70
72
73
73
74
75
Binder Engineering Group
34 Clune Street, Bayswater,
W.A. 6053 Australia.
28 Treforest Drive, Clayton,
Victoria 3168 Australia.
59 Railway Parade, Rocklea,
Queensland 4106 Australia.
7 Porter Street, Ryde,
New South Wales 2116 Australia.
27B Hamilton Road,
Singapore 209196.
Jalan Pangeran Diponegoro 108,
Bekasi Tambun, Indonesia.
Telephone (08) 9377 2900
Facsimile (08) 9377 1855
E-mail sales@bindereng.com.au
Telephone (03) 9543 9433
Facsimile (03) 9543 9633
E-mail bindervic@bigpond.com.au
Telephone (07) 3274 3230
Facsimile (07) 3274 4596
E-mail binderqld@ecn.net.au
Telephone (02) 9808 4488
Facsimile (02) 9808 4477
E-mail bindernsw@bigpond.com.au
Telephone (65) 291 5589
Facsimile (65) 297 3921
E-mail bindasia@pacific.net.sg
Telephone (62 21) 882 2150
Facsimile (62 21) 880 7334
E-mail binder_indo@ibm.net