SPEC SHEET BLINE Fiberglass Fiberglass - Straight Sections Eaton M-1 Page 8 of 113 B-Line series Cable Tray Systems Fiberglass - Accessories & Fittings Fiberglass How The Service Advisor Works We know that your time is important! That’s why the color-coding system in this catalog is designed to help you select products that fit your service needs. Products are marked to indicate the typical lead time for orders of 50 pieces or less. Customer: How do I select my straight sections. covers, or fittings so that I get the quickest turnaround? Service Advisor: Each part of our selection chart is shown in colors. If any section of a part number is a different color, the part will typically ship with the longer lead time represented by the colors. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Example: 46 FV - 09 3-5 15 3-5 - 24 - 144 3-5 3-5 Part will have a long lead time because of the FV material. Changing the part number from 46FV to 46F will change the coding to black for all sections and reduce the lead time. B-Line series Cable Tray Systems M-2 Eaton SPEC SHEET BLINE Fiberglass - Technical Data Corrosion Guide The information shown in this corrosion guide is based on full immersion laboratory tests and data generated from resin manufacturer's data. It should be noted that in some of the environments listed, splashes and spill situations may result in a more corrosive situation than indicated due to the evaporation of water. Regular wash down is recommended in these situations. All data represents the best available information and is believed to be correct. The data should not be construed as a warranty of performance for that product as presented in these tables. User tests should be performed to determine suitability of service if there is any doubt or concern. Such variables as concentration, temperature, time and combined chemical effects of mixtures of chemicals make it impossible to specify the exact suitability of fiber reinforced plastics in all environments. We will be happy to supply material samples for testing. These recommendations should only be used as a guide and we do not take responsibility for design or suitability of materials for service intended. In no event will we be liable for any consequential or special damages for any defective material or workmanship including without limitation, labor charge, other expense or damage to properties resulting from loss of materials or profits or increased expenses of operations. CHEMICAL ENVIRONMENT Acetic Acid VINYL ESTER Max Oper. Max Max Oper. Wt. % Temp ˚F Wt. % Temp ˚F CHEMICAL ENVIRONMENT POLYESTER VINYL ESTER Max Wt. % Max Oper. Temp ˚F Max Wt. % Max Oper. Temp ˚F 5 70 10 120 10 210 Chromic Acid 125 50 180 Citric Acid SAT 170 SAT 200 N/R 100 75 Copper Chloride SAT 170 SAT 200 SAT 170 SAT 200 Copper Cyanide SAT 170 SAT 200 SAT 160 SAT 170 Copper Nitrate SAT 170 SAT 200 100 170 100 200 10 190 Acetic Acid 50 Acetone N/R Aluminum Chloride Aluminum Hydroxide Aluminum Nitrate SAT 150 SAT 170 Crude Oil, Sour Aluminum Sulfate SAT 180 SAT 200 Cyclohexane N/R N/R N/R N/R Ammonium Chloride SAT 170 SAT 190 Cyclohexane, Vapor ALL 100 ALL 130 Ammonium Hydroxide 1 100 10 150 Diesel Fuel 100 160 100 180 Ammonium Hydroxide 28 N/R 28 100 Diethyl Ether N/R N/R N/R N/R Ammonium Carbonate N/R N/R SAT 150 Dimethyl Phthalate N/R N/R N/R N/R Ammonium Bicarbonate 15 125 SAT 130 Ethanol 50 75 50 90 Ammonium Nitrate SAT 160 SAT 190 Ethyl Acetate N/R N/R N/R N/R Ammonium Persulfate SAT N/R SAT 150 Ethylene Chloride N/R N/R N/R N/R Ammonium Sulfate SAT 170 SAT 200 Ethylene Glycol 100 90 100 200 Amyl Alcohol ALL N/R ALL 90 Fatty Acids SAT 180 SAT 200 - 140 - 120 Ferric Chloride SAT 170 SAT 200 N/R N/R 100 140 Ferric Nitrate SAT 170 SAT 200 SAT 170 SAT 200 Amyl Alcohol Vapor Benzene 25 110 SAT 200 Ferric Sulfate Benzoic Acid SAT 150 SAT 200 Ferrous Chloride SAT 170 SAT 200 Benzoyl Alcohol 100 N/R 100 N/R Fluoboric Acid N/R N/R SAT 165 Borax SAT 170 SAT 200 Fluosilicic Acid N/R N/R SAT 70 Calcium Carbonate SAT 170 SAT 200 Formaldehyde 50 75 50 100 Calcium Chloride SAT 170 SAT 200 Formic Acid N/R N/R 50 100 25 70 25 165 Gasoline 100 80 100 150 Calcium Nitrate SAT 180 SAT 200 Glucose 100 170 100 200 Calcium Sulfate SAT 180 SAT 200 Glycerine 100 150 100 200 N/R Heptane 100 110 100 120 Benzene Sulfonic Acid Fiberglass POLYESTER Max Calcium Hydroxide Carbon Disulfide N/R Carbonic Acid Carbon Dioxide Gas N/R N/R SAT 130 SAT 180 Hexane 100 90 100 130 - 200 - 200 Hydrobromic Acid 50 120 50 120 - 200 - 200 Hydrochloric Acid 10 150 10 200 N/R N/R 100 75 Hydrochloric Acid 20 140 20 190 Chlorine, Dry Gas - 140 - 170 Hydrochloric Acid 37 75 37 95 Chlorine, Wet Gas - N/R - 180 Hydrofluoric Acid N/R N/R 15 80 SAT 80 SAT 180 Hydrogen Bromide, Dry 100 190 100 200 Carbon Monoxide Gas Carbon Tetrachloride Chlorine Water - : No Information Available Eaton N/R: Not Recommended SAT: Saturated Solution M-3 Page 10 of 113 FUM: Fumes B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Technical Data Corrosion Guide POLYESTER VINYL ESTER CHEMICAL ENVIRONMENT Max Max Oper. Max Max Oper. Wt. % Temp ˚F Wt. % Temp ˚F Hydrogen Bromide, Wet CHEMICAL ENVIRONMENT POLYESTER VINYL ESTER Max Max Oper. Max Max Oper. Wt. Temp ˚F Wt. % Temp ˚F 100 75 100 130 Potassium Hydroxide N/R N/R 25 150 Hydrogen Chloride - 120 - 200 Potassium Nitrate SAT 170 SAT 200 Hydrogen Peroxide 5 100 30 100 Potassium Permanganate 100 80 100 210 Hydrogen Sulfide, Dry 100 170 100 210 Potassium Sulfate SAT 170 SAT 200 Hydrogen Sulfide, Wet 100 170 100 210 Propylene Glycol ALL 170 ALL 200 Hypochlorous Acid 20 80 20 150 Phthalic Acid - - SAT 200 Isopropyl Alcohol N/R N/R 15 80 Sodium Acetate SAT 160 SAT 200 Kerosene 100 140 100 180 Sodium Benzoate SAT 170 SAT 200 Lactic Acid SAT 170 SAT 200 Sodium Bicarbonate SAT 160 SAT 175 Lead Acetate SAT 170 SAT 200 Sodium Bisulfate ALL 170 ALL 200 Lead Chloride SAT 140 SAT 200 Sodium Bromide ALL 170 ALL 200 Lead Nitrate SAT - SAT 200 Sodium Carbonate 10 80 35 160 Linseed Oil 100 150 100 190 Sodium Chloride SAT 170 SAT 200 Lithium Chloride SAT 150 SAT 190 Sodium Cyanide SAT 170 SAT 200 Magnesium Carbonate SAT 140 SAT 170 Sodium Hydroxide N/R N/R 50 150 Magnesium Chloride SAT 170 SAT 200 Sodium Hydroxide N/R N/R 25 80 Magnesium Hydroxide SAT 150 SAT 190 Sodium Hypochloride N/R N/R 10 150 Magnesium Nitrate SAT 140 SAT 180 Sodium Monophosphate SAT 170 SAT 200 Magnesium Sulfate SAT 170 SAT 190 Sodium Nitrate SAT 170 SAT 200 Mercuric Chloride SAT 150 SAT 190 Sodium Sulfate SAT 170 SAT 200 Mercurous Chloride SAT 140 SAT 180 Sodium Thiosulfate ALL 100 ALL 120 Methyl Ethyl Ketone N/R N/R N/R N/R Stannic Chloride SAT 160 SAT 190 Mineral Oils 100 170 100 200 Styrene N/R N/R N/R N/R N/R N/R N/R N/R Sulfated Detergent 0/50 170 0/50 200 Naphtha 100 140 100 170 Sulfur Dioxide 100 80 100 200 Nickel Chloride SAT 170 SAT 200 Sulfur Trioxide 100 80 100 200 Nickel Nitrate SAT 170 SAT 200 Sulfuric Acid 93 N/R 93 N/R Nickel Sulfate SAT 170 SAT 200 Sulfuric Acid 50 N/R 50 180 Nitric Acid 5 140 5 150 Sulfuric Acid 25 75 25 190 Nitric Acid 20 70 20 100 Sulfurous Acid SAT 80 N/R N/R Oleic Acid 100 170 100 190 Tartaric Acid SAT 170 SAT 200 Oxalic Acid ALL 75 ALL 120 Tetrachloroethylene N/R N/R FUM 75 Paper Mill Liquors - 100 - 120 Toluene N/R N/R N/R N/R Perchlorethylene 100 N/R 100 N/R Trisodium Phosphate N/R N/R SAT 175 Perchloric Acid N/R N/R 10 150 Urea SAT 130 SAT 140 Perchloric Acid N/R N/R 30 80 Vinegar 100 170 100 200 Phosphoric Acid 10 160 10 200 Water, Distilled 100 170 100 190 Phosphoric Acid 100 120 100 200 Water, Tap 100 170 100 190 Potassium Aluminum Sulfate SAT 170 SAT 200 Water, Sea SAT 170 SAT 190 50 80 50 140 Xylene N/R N/R N/R N/R Potassium Bicarbonate Potassium Carbonate 10 N/R 10 120 Zinc Chloride SAT 170 SAT 200 Potassium Chloride SAT 170 SAT 200 Zinc Nitrate SAT 170 SAT 200 Potassium Dichromate SAT 170 SAT 200 Zinc Sulfate SAT 170 SAT 200 - : No Information Available B-Line series Cable Tray Systems N/R: Not Recommended SAT: Saturated Solution M-4 Page 11 of 113 FUM: Fumes Eaton Fiberglass Monochlorobenzene SPEC SHEET BLINE Fiberglass - Technical Data Load Data Fiberglass Cable Tray and Cable Channel are offered in three (3) versions for applications as follows: Standard Series 13F, 24F, 36F, 46F, 48F FCC-03, FCC-04, FCC-06, FCC-08 Resin Type Color Fire Retardant Polyester Gray ASTM E-84 Class 1 - UL94 VO Good Corrosion Resistance in most environments Meets Fire Retardant Vinyl Ester Beige ASTM E-84 Class 1 - UL94 VO Improved Corrosion Resistance For more severe environments Higher Heat Distortion Temperature High Performance 13FV, 24FV, 36FV, 46FV, 48FV FCCV-03, FCCV-04, FCCV-06, FCCV-08 Effect of Temperature Strength properties of reinforced plastics are reduced when continuously exposed to elevated temperatures. Working loads shall be reduced based on the chart to the right: Temperature in Degrees F Approximate Percent of Strength 75 100 125 150 175 200 100 90 78 68 60 52 NEMA Standard 8-10-1986 If unusual temperature conditions exist, the manufacturer should be consulted. Authorized Engineering information 8-20-1986 Typical Properties of Pultruded Components Flame Resistance (FTMS 406-2023) ign/burn, seconds Fiberglass Eaton B-Line Division Fiberglass Cable Tray systems are manufactured from glass fiber-reinforced plastic shapes that meet ASTM E-84, Smoke Density rating for polyester of 680, for vinyl ester 1025, Class 1 Flame Rating and self-extinguishing requirements of ASTM D-635. A surface veil is applied during pultrusion to insure a resin-rich surface and ultraviolet resistance. Properties Test Method Unit/ Value Density Coefficient of Thermal Expansion Water Absorption Dielectic Strength Flammability Classification Flame Spread ASTM D1505 ASTM D696 ASTM D570 ASTM D149 UL94 ASTM E-84 lbs/in3 in/in/˚F Max % V/mil (vpm) VO 20 Max 75/75 Intermittent Flame Test (HLT-15), rating 100 Flammability Test (ASTM D635) Ignition Burning Time none 0 sec. 3" & 4" Cable Tray, Cable Channel 6" Cable Tray Longitudinal Transverse Longitudinal Transverse .058-.062 5.0 x 10-6 0.5 200 - - .072 - .076 5.0 x 10-6 0.5 200 - - Expansion or Contraction for Various Temperature Differences Temperature Differential 25°F 50°F 75°F 100°F 125°F 150°F 175°F (13.9°C) (27.8°C) (41.7°C) (55.6°C) (69.4°C) (83.3°C) (97.2°C) Cable Tray Length for 1" Expansion 667 Feet 333 Feet 222 Feet 167 Feet 133 Feet 111 Feet 95 Feet Tray Length for Each Expansion Connector* (203.3m) (101.5m) (67.6m) (50.9m) (40.5m) (33.8m) (28.9m) 417 Feet 208 Feet 139 Feet 104 Feet 83 Feet 69 Feet 59 Feet (127.1m) (63.4m) (42.3m) (31.7m) (25.3m) (21.0m) (18.0m) Note for gap set and hold down/guide location, see installation instruction above. *1" (25.4mm) slotted holes in each expansion connector allow 5⁄8" (15.9mm) total expansion or contraction. Authorized Engineering Information 8-20-1986 Eaton M-5 Page 12 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Technical Data Cable Tray Installation Guide Installation of B-Line fiberglass cable tray should be made in accordance with the standards set by NEMA Publication VE-2, Cable Tray Installation Guide, and National Electrical Code, Article 318. - Always observe common safety practices when assembling tray and fittings. Installations generally require some field cutting. Dust created during fabrication presents no serious health hazard, but skin irritation may be experienced by some workers. Operators of saws and drills should wear masks, long sleeve shirts or coveralls. Fabrication with fiberglass is relatively easy and comparable to working with wood. Ordinary hand tools may be used in most cases. Avoid excessive pressure when sawing or drilling. Too much force can rapidly dull tools and also produce excessive heat which softens the bonding resin in the fiberglass resulting in a ragged edge rather than a clean-cut edge. Field cutting is simple and can be accomplished with a circular power saw with an abrasive cut-off wheel (masonry type) or hack saw (24 to 32 teeth per inch). Drill fiberglass as you would drill hard wood. Standard twist drills are more than adequate. Any surface that has been drilled, cut, sanded or otherwise broken, must be sealed with a compatible resin. (see page M-28) Carbide tipped saw blades and drill bits are recommended when cutting large quantities. Support the fiberglass material firmly during cutting operations to keep material from shifting which may cause chipping at the cut edge. Each tray section length should be equal to or greater than the support span. When possible, the splice should be located at quarter span. Fittings should be supported as per NEMA FG-1. Recommended Fiberglass Trapeze Hanging Systems Notes: 1) A snug three to four ft.-lbs. torque is sufficient for all thread rod nuts. 2) When supporting cable tray, the spacing between each trapeze should not exceed the distance between splice plates. 3) When hanging from beam, B-Line series BFV751 series clamps provide extra thread engagement necessary for load ratings. All thread rod must be fully engaged in the clamp. 4) Design load safety factor is 3:1 BF22A Strut: 2" max between material being supported and rod 1 ⁄2" fiberglass all-thread rod (BFVATR 1⁄2) fiberglass ATR nut (BFVATRHN 1⁄2) maximum uniform load 1,500 lbs. fiberglass spacer (BFV202) BF22A fiberglass strut Fiberglass fiberglass spacer (BFV202) 1 ⁄2" (13mm) Min. fiberglass ATR nut (BFVATRHN 1⁄2) 40" (1016mm) Max. 2" (51mm) Min. BF22 Strut: 2" max between material being supported and rod 1 ⁄2" fiberglass all-thread rod (BFVATR 1⁄2) maximum uniform load 500 lbs. fiberglass ATR nut (BFVATRHN 1⁄2) fiberglass spacer (BFV202) BF22 fiberglass strut fiberglass spacer (BFV202) 1 ⁄2" (13mm) Min. fiberglass ATR nut (BFVATRHN 1⁄2) 40" (1016mm) Max. 2" (51mm) Min. For vinyl ester resin, ‘V’ must be added appropriately to part number. Example: BFV22A. B-Line series Cable Tray Systems M-6 Page 13 of 113 Eaton SPEC SHEET BLINE Fiberglass - Recommended Tray Specification SECTION 161xx NON-METALLIC CABLE TRAY POLYESTER, VINYL ESTER PART 1 - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, tests and services to install complete cable tray systems as shown on the drawings. B. Cable tray systems are defined to include, but are not limited to straight sections of [ladder type] [vented bottom type] [solid bottom type] cable trays, bends, tees, elbows, drop-outs, supports and accessories. 1.02 REFERENCES A. ANSI/NFPA 70 – National Electrical Code B. NEMA FG 1-2002 – Non-Metallic Cable Tray Systems C. NEMA VE 2-2002 – Cable Tray Installation Guidelines 1.03 DRAWINGS A. The drawings, which constitute a part of these specifications, indicate the general route of the cable tray systems. Data presented on these drawings are as accurate as preliminary surveys and planning can determine until final equipment selection is made. Accuracy is not guaranteed and field verification, of all dimensions, routing, etc., is directed. B. Specifications and drawings are for assistance and guidance, but exact routing, locations, distances and levels will be governed by actual field conditions. Contractor is directed to make field surveys as part of his work prior to submitting system layout drawings. Fiberglass 1.04 SUBMITTALS A. Submittal Drawings: Submit drawings of cable tray and accessories including clamps, brackets, hanger rods, splice plate connectors, expansion joint assemblies, and fittings, showing accurately scaled components. B. Product Data: Submit manufacturer's data on cable tray including, but not limited to, types, materials, finishes, rung spacings, inside depths and fitting radii. For side rails and rungs, submit cross sectional properties including Section Modulus (Sx) and Moment of Inertia (Ix). 1.05 QUALITY ASSURANCE A. Manufacturers: Firms regularly engaged in manufacture of cable trays and fittings of types and capacities required, whose products have been in satisfactory use in similar service for not less than 5 years. B. NEMA Compliance: Comply with NEMA Standards Publication Number FG-1, "Non-Metallic Cable Tray Systems". C. NEC Compliance: Comply with NEC, as applicable to construction and installation of cable tray and cable channel systems (Article 318, NEC). 1.06 DELIVERY, STORAGE AND HANDLING A. Deliver cable tray systems and components carefully to avoid breakage, denting and scoring finishes. Do not install damaged equipment. B. Store cable trays and accessories in original cartons and in clean dry space; protect from weather and construction traffic. Wet materials should be unpacked and dried before storage. continued on page M-8 Eaton M-7 Page 14 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Recommended Tray Specification PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. Subject to compliance with these specifications, Eaton’s B-Line series cable tray systems shall be as manufactured by Eaton. 2.02 CABLE TRAY SECTIONS AND COMPONENTS A. General: Except as otherwise indicated, provide non-metallic cable trays, of types, classes, and sizes indicated; with splice plates, bolts, nuts and washers for connecting units. Construct units with rounded edges and smooth surfaces; in compliance with applicable standards; and with the following additional construction features. Cable tray shall be installed according to the latest revision of NEMA VE 2. B. Material and Finish: Straight section structural elements; side rails, rungs and splice plates shall be pultruded from glass fiber reinforced polyester resin, vinyl ester resin or dis-stat. C. Pultruded shapes shall be constructed with a surface veil to insure a resin-rich surface and ultraviolet resistance. D. Pultruded shapes shall meet ASTM E-84, Class 1 flame rating and self-extinguishing requirements of ASTM D-635. 2.03 TYPE OF TRAY SYSTEM Ladder Cable Trays shall consist of two longitudinal members (side rails) with transverse members (rungs) mechanically fastened and adhesively bonded to the side rails. Rungs shall be spaced [6] [9] [12] inches apart. Rung spacing in radiused fittings shall be industry standard 9" and measured at the center of the tray’s width. Each rung must be capable of supporting a 200 lb. concentrated load at the center of the cable tray with a safety factor of 1.5 (See following rung loading table). B. Ventilated Bottom Cable Trays shall consist of two longitudinal members (side rails) with rungs spaced 4" apart. C. Solid Bottom Cable Trays shall consist of two longitudinal members (side rails) with a solid sheet over rungs spaced on 12" centers. D. Cable tray loading depth shall be [2] [3] [5] inches per NEMA FG 1. E. Straight sections shall be supplied in standard [10 foot (3m)] [20 foot (6m)] lengths. F. Cable tray inside widths shall be [6] [9] [12] [18] [24] [30] [36] inches or as shown on drawings. Outside width shall not exceed inside by more than a total of 2". G. Straight and expansion splice plates will be of "L" shaped lay-in design with an eight-bolt pattern in 5" fill systems and four-bolt pattern in 3" and 2" fill systems. Splice plates shall be furnished with straight sections and fittings. H. All fittings must have a minimum radius of [12] [24] [36]. I. Fittings shall be of mitered construction. J. Dimension tolerances will be per NEMA FG 1. Fiberglass A. 2.04 LOADING CAPACITIES A. Cable trays shall meet NEMA class designation: [8C] [12C] [20B] [20C]. Or A. Cable tray shall be capable of carrying a uniformly distributed load of _______ lbs./ft on a _______ foot support span with a safety factor of 1.5 when supported as a simple span and tested per NEMA VE 1 Section 5.2. continued on page M-9 B-Line series Cable Tray Systems M-8 Page 15 of 113 Eaton SPEC SHEET BLINE Fiberglass - Recommended Tray Specification PART 3 - EXECUTION 3.01 INSTALLATION A. Install cable trays as indicated: Installation shall be in accordance with equipment manufacturer's instructions, and with recognized industry practices to ensure that cable tray equipment comply with requirements of NEC and applicable portions of NFPA 70B. Reference NEMA VE 2 for general cable tray installation guidelines. B. Coordinate cable tray with other electrical work as necessary to properly integrate installation of cable tray work with other work. C. Provide sufficient space encompassing cable trays to permit access for installing and maintaining cables. D. Cable tray fitting supports shall be located such that they meet the strength requirements of straight sections. Install fitting supports per NEMA VE 2 guidelines, or in accordance with manufacturer's instructions. 3.02 TESTING Upon request manufacturer shall provide test reports witnessed by an independent testing laboratory of the "worst case" loading conditions outlined in this specification and performed in accordance with the latest revision of NEMA FG 1. Fiberglass A. Eaton M-9 Page 16 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Cable Tray Numbering System To order a Fiberglass straight section of cable tray, select the appropriate size and material from the charts below and place those symbols in the sequence shown to form the complete catalog number. Procedure: 1. Select the correct B-Line series Fiberglass tray using the Load Data for straight sections shown on page M-11 for 3", page M-12 for 4", page M-13 & M-14 for 6", and page M-15 for 8" fittings. 2. Select the resin required. Polyester or Vinyl Ester. Refer to Corrosion Guide on pages M-3 and M-4, for the effect of environmental conditions on the desired material and the effective temperature range on page M-5. 3. The tray prefix is completed by inserting the rung spacing. 4. Select the desired width in inches. 5. Finally select the straight section length in inches. Fiberglass 120 [10'] (3m) or 240 [20'] (6m) Straight Section Part Numbering Prefix Example: 24 F 09 - 24 - 120 Series Material Rung Spacing 13 24 36 46 48 F - Fiberglass (Gray) Polyester Resin FV - Fiberglass (Beige) Vinyl Ester Resin 06 = 6" (152) 09 = 9" (228) 12 = 12" (305) † SB = Solod Bottom *See page APP-1 for Marine Rung option. Width 06 = 6" 09 = 9" 12 = 12" 18 = 18" 24 = 24" 30 = 30" 36 = 36" Length (152) (228) (305) (457) (609) (762) (914) 120 = 120” (3m) 240 = 240” (6m) † Solid bottom sheets ship separately with connecting handware and assembled on site. Note: One pair of splice plates with SS6 hardware included. Fiberglass Fitting Section Part Selector Prefix Example: 4 F SB - 24 - Height Material Bottom 3" (76) 4" (101) 6" (152) 8" (203) F - Fiberglass (Gray) Polyester Resin FV - Fiberglass (Beige) Vinyl Ester Resin Blank = Ladder Type SB = Solid Bottom 90 HB Width 6" 9" 12" 18" 24" 30" 36" 24 Angle (152) (228) (305) (457) (609) (762) (914) Notes: Standard rung spacing on fittings is 9" (225). Splice plates with SS6 hardware included. B-Line series Cable Tray Systems M-10 Page 17 of 113 45˚ 90˚ Type HB HT HX VI VO VT VTU RR LR SR - Horizontal Bend Horizontal Tee Horizontal Cross Vertical Inside Bend Vertical Outside Bend Vertical Tee - Vertical Tee, Up Right Reducer Left Reducer Straight Reducer Radius 12" (305) 24" (609) 36" (914) Eaton SPEC SHEET BLINE Fiberglass - 3” Straight Section 1" (25) Rung Spacing NEMA 2" Fill 3" (76) For side rail data, see charts on pages APP-8 1" (25) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Overall Width (Width + 7/8”) Series 13 Fiberglass Straight Section Part Numbering Prefix Example: 13 F 09 - 24 - 120 Series Material 13 F = Polyester FV = Vinyl Ester Type Width Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing SB = Solid bottom † 06 09 12 18 24 = = = = = Length 1 120 = 10 ft. 2 240 = 20 ft. 6" 9" 12" 18" 24" 1 Primary Length. 2 Secondary Length. See page C-23 for explanation of lengths. See page M-34 for additional rung options. Fiberglass B-Line Series 13F 13FV Side Rail Dimensions NEMA Classifications 1.00 NEMA: 8C NEMA 2” fill 3.00 1.00 Span ft † Solid bottom sheets ship separately with connecting handware and assembled on site. Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier 6 257 0.005 1.8 382 0.086 8 145 0.016 2.4 216 0.267 10 93 0.040 3.0 138 0.681 12 64 0.083 3.7 95 1.411 14 47 0.153 4.3 70 2.614 Values are based on simple beam tests per NEMA FG-1 on 24" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-11 Page 18 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - 4” Straight Section 11⁄8" (28) NEMA 3" Rung Spacing 4" (101) For side rail data, see charts on pages APP-8 1" (25) Overall Width (Width + 7/8”) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Series 24 Fiberglass Straight Section Part Numbering Prefix Example: 24 F 09 - 24 - 120 Series 24 Material F = Polyester FV = Vinyl Ester Type Side Rail Dimensions NEMA & CSA Classifications 24F 24FV = = = = = = = Length 1 120 = 10 ft. 2 240 = 20 ft. 6" 9" 12" 18" 24" 30" 36" 1 Primary Length. 2 Secondary Length. See page C-23 for explanation of lengths. Span ft Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier NEMA: 12C 6 627 0.001 1.8 933 0.023 CSA: E-3m 8 353 0.004 2.4 525 0.074 10 226 0.011 3.0 336 0.182 12 157 0.022 3.7 233 0.378 NEMA 3” fill 4.00 Fiberglass 1.125 06 09 12 18 24 30 36 † Solid bottom sheets ship separately with connecting handware and assembled on site. See page M-34 for additional rung options. B-Line Series Width Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing SB = Solid bottom † 1.00 Values are based on simple beam tests per NEMA FG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-12 Page 19 of 113 Eaton SPEC SHEET BLINE Fiberglass - 6” Straight Section 15⁄8" (41) Rung Spacing NEMA 5" fill 6" (152) For side rail data, see charts on pages APP-8 Overall Width (Width + 7/8”) One pair of splice plates with SS6 (316 Stainless Steel) hardware included 1" (25) Series 36 Fiberglass Straight Section Part Numbering Prefix Example: 36 F 09 - 24 - 120 Series 36 Material F = Polyester FV = Vinyl Ester Type See page M-34 for additional rung options. Fiberglass B-Line Series Side Rail Dimensions 1.625 36F 36FV NEMA & CSA Classifications Width Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing SB = Solid bottom † 06 09 12 18 24 30 36 = = = = = = = Length 1 120 = 10 ft. 2 240 = 20 ft. 6" 9" 12" 18" 24" 30" 36" 1 Primary Length. 2 Secondary Length. See page C-23 for explanation of lengths. † Solid bottom sheets ship separately with connecting handware and assembled on site. Span ft Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier NEMA: 20B 12 241 0.005 3.7 359 0.081 CSA: E-6m 14 177 0.009 4.3 264 0.151 16 136 0.015 4.9 202 0.257 18 107 0.024 5.5 159 0.411 20 87 0.037 6.1 129 0.627 NEMA 5” fill 6.00 1.00 Values are based on simple beam tests per NEMA FG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-13 Page 20 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - 6” Straight Section 15⁄8" (41) Rung Spacing NEMA 5" fill For side rail data, see charts on pages APP-8 6" (152) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Overall Width (Width + 1”) 1" (25) Series 46 Fiberglass Straight Section Part Numbering Prefix Example: 46 F 09 - 24 - 120 Series 46 Material F = Polyester FV = Vinyl Ester Type Side Rail Dimensions 46F 46FV = = = = = = = Length 1 120 = 10 ft. 2 240 = 20 ft. 6" 9" 12" 18" 24" 30" 36" 1 Primary Length. 2 Secondary Length. See page C-23 for explanation of lengths. NEMA & CSA Classifications Span ft Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier NEMA: 20C+ 12 393 0.005 3.7 584 0.079 CSA: E-6m 14 288 0.009 4.3 429 0.145 16 221 0.015 4.9 329 0.246 18 174 0.023 5.5 260 0.396 20 141 0.035 6.1 210 0.605 NEMA 5” fill 6.00 Fiberglass 1.625 06 09 12 18 24 30 36 † Solid bottom sheets ship separately with connecting handware and assembled on site. See page M-34 for additional rung options. B-Line Series Width Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing SB = Solid bottom † 1.00 Values are based on simple beam tests per NEMA FG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-14 Page 21 of 113 Eaton SPEC SHEET BLINE Fiberglass - 8” Straight Section 23/16" (55) Rung Spacing NEMA 7" fill 8" (203) For side rail data, see charts on pages APP-8 Overall Width (Width + 7/8”) 1" (25) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Series 48 Fiberglass Straight Section Part Numbering Prefix Example: 48 F 09 - 24 - 120 Series 48 Material F = Polyester FV = Vinyl Ester Type See page M-34 for additional rung options. Fiberglass B-Line Series Side Rail Dimensions NEMA: 20C+ 2.188 48F 48FV NEMA Classifications NEMA 7” fill 8.00 Width Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing SB = Solid bottom † Span ft 06 09 12 18 24 30 36 = = = = = = = 6" 9" 12" 18" 24" 30" 36" Length 1 120 = 10 ft. 2 240 = 20 ft. 1 2 Primary Length. Secondary Length. See page C-23 for explanation of lengths. † Solid bottom sheets ship separately with connecting handware and assembled on site. Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier 12 348 0.003 3.7 518 0.052 14 256 0.006 4.3 381 0.097 16 196 0.010 4.9 291 0.165 18 155 0.015 5.5 231 0.210 20 125 0.024 6.1 187 0.401 1.00 Values are based on simple beam tests per NEMA FG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-15 Page 22 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fitting Numbering System Fiberglass Fittings Part Numbering Prefix Example: 4 F 3 4 6 8 = = = = 3” ** 4” 6” 8” Material Bottom F = Polyester FV = Vinyl Ester Blank = Ladder Type SB = Solid Bottom† 06 09 12 18 24 30 36 (9" rung spacing is standard) Width Angle Type Radius = 6" (152) = 9" (228) = 12" (305) = 18" (457) = 24" (609) = 30" (762) = 36" (914) 45 = 45° HB = Horizontal Bend HT = Horizontal Tee HX = Horizontal Cross VI = Vertical Inside Bend VO = Vertical Outside Bend LR = Left Reducer RR = Right Reducer SR = Straight Reducer 12 = 12" (305) 24 = 24" (609) 36 = 36" (914) ** 3” deep fittings are available in 6” thru 24” widths and 12” radius only. 90 = 90° † Solid bottom sheets ship separately with connecting handware and assembled on site. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-16 Page 23 of 113 Eaton Fiberglass Height SB - 12 - 90 HB 12 SPEC SHEET BLINE Fiberglass - Fittings Horizontal Bend 90° (HB) Prefix - 06 - 90 HB 12 Radius Fitting Angle Width To complete catalog number, insert fitting prefix. B R A 90˚ Mitered One pair of splice plates with SS6 hardware required to connect to system. -RBend Radius in. (mm) 12 (305) Tray Width in. (mm) 6 (152) 9 (228) Fiberglass B (mm) in. (mm) (Prefix)-06-90HB12 2811/16 (728) 2811/16 (728) (Prefix)-09-90HB12 303/16 (767) 303/16 (767) 12 (305) (Prefix)-12-90HB12 3111/16 (805) 3111/16 (805) 18 (457) (Prefix)-18-90HB12 3411/16 (881) 3411/16 (881) 24 (609) (Prefix)-24-90HB12 3711/16 (957) 3711/16 (957) 30 (762) (Prefix)-30-90HB12 4011/16 (1033) 4011/16 (1033) 36 (914) (Prefix)-36-90HB12 4311/16 (1109) 4311/16 (1109) 6 (Prefix)-06-90HB24 41 (1041) 41 (1041) (1079) (152) (228) (Prefix)-09-90HB24 421/2 (1079) 421/2 12 (305) (Prefix)-12-90HB24 44 (1117) 44 (1117) 18 (457) (Prefix)-18-90HB24 47 (1193) 47 (1193) 24 (609) (Prefix)-24-90HB24 50 (1269) 50 (1269) 30 (762) (Prefix)-30-90HB24 53 (1346) 53 (1346) 36 (914) (Prefix)-36-90HB24 56 (1422) 56 (1422) 6 (Prefix)-06-90HB36 531/4 (1353) 531/4 (1353) (1391) (152) (228) (Prefix)-09-90HB36 543/4 (1391) 543/4 12 (305) (Prefix)-12-90HB36 561/4 (1429) 561/4 (1429) 18 (457) (Prefix)-18-90HB36 591/4 (1505) 591/4 (1505) 24 (609) (Prefix)-24-90HB36 621/4 (1582) 621/4 (1582) 30 (762) (Prefix)-30-90HB36 651/4 (1658) 651/4 (1658) (Prefix)-36-90HB36 681/4 (1734) 681/4 (1734) 9 36 (914) 90˚ Horizontal Bend - Mitered Dimensions A Catalog No. in. 9 24 (609) (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. 36 (914) For 3” Fittings For 6” Fittings (Tray Widths - 6” thru 24” • Radius 12” only) Polyester, Vinyl Ester All are mitered (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-17 Page 24 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fittings Horizontal Bend 45° (HB) C Prefix - 06 - 45 HB 12 C Radius Fitting Angle Width To complete catalog number, insert fitting prefix. B R A One pair of splice plates with SS6 hardware required to connect to system. 45˚ Mitered (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. -RBend 45˚ Horizontal Bend - Mitered Dimensions Tray Radius Width in. in. (mm) 12 (305) (mm) B (mm) in. C (mm) (mm) 6 (152) (Prefix)-06-45HB12 (259) 9 (228) (Prefix)-09-45HB12 2523/32 (653) 1021/32 (271) 151/16 (383) 12 (305) (Prefix)-12-45HB12 2625/32 (680) 113/32 (282) 1511/18 (398) (Prefix)-18-45HB12 2829/32 (734) 1131/32 (304) 1615/16 (430) (Prefix)-24-45HB12 311/32 1227/32 (326) 185/32 (462) 30 (762) (Prefix)-30-45HB12 335/32 36 (914) (Prefix)-36-45HB12 351/4 18 (457) (788) 107/32 in. 147/16 (367) (842) 133/4 (349) 1913/32 (493) (896) 145/8 (371) 2021/32 (525) 107/32 (259) 147/16 (367) 6 (152) (Prefix)-06-45HB12 2421/32 (626) 9 (Prefix)-09-45HB12 2523/32 (653) 1021/32 (271) 151/16 (383) (Prefix)-12-45HB12 2625/32 (680) 113/32 (282) 1511/18 (398) 18 (457) (Prefix)-18-45HB12 2829/32 (734) 1131/32 (304) 1615/16 (430) 24 (609) (Prefix)-24-45HB12 311/32 1227/32 (326) 185/32 (462) 30 (762) (Prefix)-30-45HB12 335/32 (842) 133/4 (349) 1913/32 (493) 36 (914) (Prefix)-36-45HB12 351/4 145/8 (371) 2021/32 (525) 6 (152) (Prefix)-06-45HB12 2421/32 (626) 107/32 (259) 147/16 (367) 9 (228) (Prefix)-09-45HB12 2523/32 (653) 1021/32 (271) 151/16 (383) (Prefix)-12-45HB12 2625/32 (680) 113/32 (282) 1511/18 (398) 18 (457) (Prefix)-18-45HB12 2829/32 (734) 1131/32 (304) 1615/16 (430) 24 (609) (Prefix)-24-45HB12 311/32 (788) 1227/32 (326) 30 (762) (Prefix)-30-45HB12 335/32 (842) 133/4 (349) 1913/32 (493) 36 (914) (Prefix)-36-45HB12 351/4 145/8 (371) 2021/32 (525) (788) (896) (896) Fiberglass (228) 12 (305) 12 (305) 36 (914) in. 2421/32 (626) 24 (609) 24 (609) A Catalog No. 185/32 (462) For 3” Fittings For 6” Fittings (Tray Widths - 6” thru 24” • Radius 12” only) Polyester, Vinyl Ester All are mitered (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-18 Page 25 of 113 Eaton SPEC SHEET BLINE Fiberglass - Fittings Horizontal Tee (HT) B Prefix - 06 - HT 12 W Radius Fitting Width To complete catalog number, insert fitting prefix. R A Mitered Tee (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. Two pair of splice plates with SS6 hardware required to connect to system. -RBend Radius in. (mm) in. (mm) in. (mm) 6 (152) (Prefix)-06-HT12 287/32 (716) 5613/32 (1433) 9 (228) (Prefix)-09-HT12 2911/16 (754) 5913/32 (1509) (Prefix)-12-HT12 317/32 (792) 6213/32 (1585) (869) 6813/32 (1737) 12 12 (305) Fiberglass (mm) 18 (457) (Prefix)-18-HT12 24 (609) (Prefix)-24-HT12 377/32 (945) 7413/32 (1890) 30 (762) (Prefix)-30-HT12 407/32 (1021) 8013/32 (2042) 36 (914) (Prefix)-36-HT12 437/32 (1097) 8613/32 (2195) 6 (152) (Prefix)-06-HT24 407/32 (1021) 8013/32 (2042) 9 (228) (Prefix)-09-HT24 4111/16 (1059) 8313/32 (2118) (Prefix)-12-HT24 437/32 (1097) 8613/32 (2195) (1173) 9213/32 (2347) (305) 18 (457) (Prefix)-18-HT24 467/32 24 (609) (Prefix)-24-HT24 497/32 (1250) 9813/32 (2499) 30 (762) (Prefix)-30-HT24 527/32 (1326) 10413/32 (2652) 36 (914) (Prefix)-36-HT24 557/32 (1402) 11013/32 (2804) 6 (152) (Prefix)-06-HT36 527/32 (1326) 10413/32 (2652) (Prefix)-09-HT36 5311/16 (1364) 10713/32 (2728) (Prefix)-12-HT36 557/32 (1402) 11013/32 (2804) (1478) 11613/32 (2957) 9 (228) 12 36 (914) (305) in. 347/32 12 24 (609) Horizontal Tee - Mitered Dimensions A B Catalog No. Tray Width (305) 18 (457) (Prefix)-18-HT36 587/32 24 (609) (Prefix)-24-HT36 617/32 (1554) 12213/32 (3109) 30 (762) (Prefix)-30-HT36 647/32 (1631) 12813/32 (3261) (Prefix)-36-HT36 677/32 (1707) 13413/32 (3414) 36 (914) For 3” Fittings For 6” Fittings (Tray Widths - 6” thru 24” • Radius 12” only) Polyester, Vinyl Ester All are mitered (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered (Tray Widths - 6” thru 36” • Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-19 Page 26 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fittings Horizontal Cross (HX) B Prefix - 06 - HX 12 Radius Fitting Width To complete catalog number, insert fitting prefix. W A in. (mm) 12 (305) Tray Width in. 6 (152) (Prefix)-06-HX12 283/16 (716) 5613/32 (1433) 9 (228) (Prefix)-09-HX12 2911/16 (754) 5913/32 (1509) 12 (305) (Prefix)-12-HX12 313/16 (792) 6213/32 (1585) 18 (457) (Prefix)-18-HX12 343/16 (869) 6813/32 (1737) (Prefix)-24-HX12 373/16 (945) 7413/32 (1890) 30 (762) (Prefix)-30-HX12 403/16 (1021) 8013/32 (2042) 36 (914) (Prefix)-36-HX12 433/16 (1097) 8613/32 (2195) (Prefix)-06-HX24 403/16 (1021) 8013/32 (2042) (228) (Prefix)-09-HX24 4111/16 (1059) 8313/32 (2118) 12 (305) (Prefix)-12-HX24 433/16 (1097) 8613/32 (2195) 18 (457) (Prefix)-18-HX24 463/16 (1173) 9213/32 (2347) (Prefix)-24-HX24 493/16 (1250) 9813/32 (2499) 30 (762) (Prefix)-30-HX24 523/16 (1326) 10413/32 (2652) 36 (914) (Prefix)-36-HX24 553/16 (1402) 11013/32 (2804) 9 (152) 24 (609) (mm) in. B in. 6 (mm) 6 (152) (Prefix)-06-HX36 523/16 (1326) 10413/32 (2652) 9 (228) (Prefix)-09-HX36 5311/16 (1364) 10713/32 (2728) 12 (305) (Prefix)-12-HX36 553/16 (1402) 11013/32 (2804) (Prefix)-18-HX36 583/16 (1478) 11613/32 (2957) 24 (609) (Prefix)-24-HX36 613/16 (1554) 12213/32 (3109) 30 (762) (Prefix)-30-HX36 643/16 (1631) 12813/32 (3261) 36 (914) (Prefix)-36-HX36 673/16 (1707) 13413/32 (3414) 18 (457) For 3” Fittings For 6” Fittings (Tray Widths - 6” thru 24” • Radius 12” only) Polyester, Vinyl Ester All are mitered (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered (Tray Widths - 6” thru 36” Radius 12”, 24” & 36”) Polyester, Vinyl Ester All radius are mitered Fiberglass 36 (914) Horizontal Cross - Mitered Dimensions A Catalog No. (mm) 24 (609) 24 (609) (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. Mitered Cross Three pair of splice plates with SS6 hardware required to connect to system. -RBend Radius R Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-20 Page 27 of 113 Eaton SPEC SHEET BLINE Fiberglass - Fittings Reducers (LR) (SR) (RR) W2 One pair of splice plates with SS6 hardware required to connect to system. W2 A A A W1 W1 W1 Left Reducer Straight Reducer Right Reducer Prefix - 12 - SR 09 3” Fittings Width2 W2 Fitting Width1 W1 To complete catalog number, insert fitting prefix. (Only available in W1 widths of 9”, 12”, 18” & 24”) 4”, 6” & 8” Fittings Polyester, Vinyl Ester Available in all heights (Available in all W1 widths shown in chart) Reducers are all of mitered construction. Tray Width W1 in. (mm) 9 (228) 12 (305) 18 (457) Fiberglass W2 24 (609) 30 (762) 36 (914) Left Hand Reducer W2 in. (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. A Catalog No. (mm) in. Straight Reducer Right Hand Reducer A Catalog No. A Catalog No. (mm) in. (mm) in. (mm) 6 (152) (Prefix)-09-LR06 21 (533) (Prefix)-09-SR06 191/2 (495) (Prefix)-09-RR06 21 (533) 6 (152) (Prefix)-12-LR06 24 (609) (Prefix)-12-SR06 21 (533) (Prefix)-12-RR06 24 (609) 9 (228) (Prefix)-12-LR09 21 (533) (Prefix)-12-SR09 191/2 (495) (Prefix)-12-RR09 21 (533) 6 9 (152) (Prefix)-18-LR06 30 (762) (Prefix)-18-SR06 24 (609) (Prefix)-18-RR06 30 (762) (228) (Prefix)-18-LR09 27 (686) (Prefix)-18-SR09 221/2 (571) (Prefix)-18-RR09 27 (686) 12 (305) (Prefix)-18-LR12 24 (609) (Prefix)-18-SR12 21 (533) (Prefix)-18-RR12 24 (609) 6 9 (Prefix)-24-LR06 36 (914) (Prefix)-24-SR06 27 (686) (Prefix)-24-RR06 36 (914) (152) (228) (Prefix)-24-LR09 33 (838) (Prefix)-24-SR09 251/2 (648) (Prefix)-24-RR09 33 (838) 12 (305) 18 (457) (Prefix)-24-LR12 30 (762) (Prefix)-24-SR12 24 (609) (Prefix)-24-RR12 30 (762) (Prefix)-24-LR18 24 (609) (Prefix)-24-SR18 21 (533) (Prefix)-24-RR18 24 (609) 6 9 (152) (Prefix)-30-LR06 42 (1067) (Prefix)-30-SR06 30 (762) (Prefix)-30-RR06 42 (1067) (228) (Prefix)-30-LR09 39 (990) (Prefix)-30-SR09 281/2 (724) (Prefix)-30-RR09 39 (990) 12 (305) 18 (457) (Prefix)-30-LR12 (Prefix)-30-LR18 36 30 (914) 27 24 (686) (609) (Prefix)-30-RR12 (Prefix)-30-RR18 36 30 (914) (762) (Prefix)-30-SR12 (Prefix)-30-SR18 24 (609) (Prefix)-30-LR24 24 (609) (Prefix)-30-SR24 21 (533) (Prefix)-30-RR24 24 (609) 6 9 48 45 (1219) 33 311/2 (800) (Prefix)-36-RR06 (Prefix)-36-RR09 48 45 (1219) (1143) (Prefix)-36-SR06 (Prefix)-36-SR09 (838) (228) (Prefix)-36-LR06 (Prefix)-36-LR09 12 (305) (Prefix)-36-LR12 42 (1067) (Prefix)-36-SR12 30 (762) (Prefix)-36-RR12 42 (1067) 18 (457) (Prefix)-36-LR18 36 (914) (Prefix)-36-SR18 27 (686) (Prefix)-36-RR18 36 (914) 24 (609) (Prefix)-36-LR24 30 (762) (Prefix)-36-SR24 24 (609) (Prefix)-36-RR24 30 (762) 30 (762) (Prefix)-36-LR30 24 (609) (Prefix)-36-SR30 21 (533) (Prefix)-36-RR30 24 (609) (152) (762) (1143) Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-21 Page 28 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fittings Horizontal Reducing Tee (HT) Prefix - 36 - 18 HT 24 B Radius Fitting Width2 W2 Width1 W1 To complete catalog number, insert fitting prefix. W1 A R (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. W2 Mitered Reducing Tee Two pair of splice plates with SS6 hardware required to connect to system. Tray Width W1 W2 Mitered Fittings Catalog No. * Insert radius (12", 24” or 36") 12" Radius (305) A B (mm) in. (mm) in. B 2911/16 (754) 5613/ 32 (1433) 4111/16 (1059) 8013/ 32 (2042) 5311/16 (1364) 10413/ 32 (2652) 6 (152) (Prefix)-12-06-HT* 313/16 (792) 5613/ 32 (1433) 433/16 (1097) 8013/ 32 (2042) 553/16 (1402) 10413/ 32 (2652) 9 (228) (Prefix)-12-09-HT* 313/16 (792) 5913/ 32 (1509) 433/16 (1097) 8313/ 32 (2118) 553/16 (1402) 10713/ 32 (2728) 6 (152) (Prefix)-18-06-HT* 343/16 (869) 5613/ 32 (1433) 463/16 (1173) 8013/ 32 (2042) 583/16 (1478) 10413/ 32 (2652) (mm) in. (mm) 9 (228) (Prefix)-18-09-HT* 343/16 (869) 5913/ 32 (1509) 463/16 (1173) 8313/ 32 (2118) 583/16 (1478) 10713/ 32 (2728) 12 (305) (Prefix)-18-12-HT* 343/16 (869) 6213/ 32 (1585) 463/16 (1173) 8613/ 32 (2195) 583/16 (1478) 11013/ 32 (2804) 6 (152) (Prefix)-24-06-HT* 373/ 16 (945) 5613/ 32 (1433) 493/16 (1250) 8013/ 32 (2042) 613/16 (1554) 10413/ 32 (2652) 9 (228) (Prefix)-24-09-HT* 373/ 16 (945) 5913/ 32 (1509) 493/16 (1250) 8313/ 32 (2118) 613/16 (1554) 10713/ 32 (2728) 12 (305) (Prefix)-24-12-HT* 373/ 16 (945) 6213/ 32 (1585) 493/16 (1250) 8613/ 32 (2195) 613/16 (1554) 11013/ 32 (2804) 18 (457) (Prefix)-24-18-HT* 373/ 16 (945) 6813/ 32 (1737) 493/16 (1250) 9213/ 32 (2347) 613/16 (1554) 11613/ 32 (2957) 6 (152) (Prefix)-30-06-HT* 403/ 16 (1021) 5613/ 32 (1433) 523/16 (1326) 8013/ 32 (2042) 643/16 (1631) 10413/ 32 (2652) 9 (228) (Prefix)-30-09-HT* 403/ 16 (1021) 5913/ 32 (1509) 523/16 (1326) 8313/ 32 (2118) 643/16 (1631) 10713/ 32 (2728) 12 (305) (Prefix)-30-12-HT* 403/ 16 (1021) 6213/ 32 (1585) 523/16 (1326) 8613/ 32 (2195) 643/16 (1631) 11013/ 32 (2804) 18 (457) (Prefix)-30-18-HT* 403/ 16 (1021) 6813/ 32 (1737) 523/16 (1326) 9213/ 32 (2347) 643/16 (1631) 11613/ 32 (2957) 24 (609) (Prefix)-30-24-HT* 403/ 16 (1021) 7413/ 32 (1890) 523/16 (1326) 9813/ 32 (2499) 643/16 (1631) 12213/ 32 (3109) 6 (152) (Prefix)-36-06-HT* 433/ 16 (1097) 5613/ 32 (1433) 553/16 (1402) 8013/ 32 (2042) 673/16 (1707) 10413/ 32 (2652) 9 (228) (Prefix)-36-09-HT* 433/ 16 (1097) 5913/ 32 (1509) 553/16 (1402) 8313/ 32 (2118) 673/16 (1707) 10713/ 32 (2728) 12 (305) (Prefix)-36-12-HT* 433/ 16 (1097) 6213/ 32 (1585) 553/16 (1402) 8613/ 32 (2195) 673/16 (1707) 11013/ 32 (2804) 18 (457) (Prefix)-36-18-HT* 433/ 16 (1097) 6813/ 32 (1737) 553/16 (1402) 9213/ 32 (2347) 673/16 (1707) 11613/ 32 (2957) 24 (609) (Prefix)-36-24-HT* 433/ 16 (1097) 7413/ 32 (1890) 553/16 (1402) 9813/ 32 (2499) 673/16 (1707) 12213/ 32 (3109) 30 (762) (Prefix)-36-30-HT* 433/ 16 (1097) 8013/ 32 (2042) 553/16 (1402) 10413/ 32 (2652) 673/16 (1707) 12813/ 32 (3261) For 3” Fittings For 6” Fittings (Radius 12” only W1 tray widths - 9”, 12”, 18” & 24” ) Polyester, Vinyl Ester All are mitered (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-22 Page 29 of 113 Eaton Fiberglass 36 (914) in. A 6 (152) (Prefix)-09-06-HT* 30 (762) (mm) B 9 (228) 24 (609) in. A in. (mm) 18 (457) (mm) 36" Radius (914) in. (mm) 12 (305) in. 24" Radius (609) SPEC SHEET BLINE Fiberglass - Fittings Horizontal Expanding Tee (HT) Prefix - 18 - 36 HT 24 B Radius Fitting Width2 W2 Width1 W1 To complete catalog number, insert fitting prefix. W1 R A (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. W2 Mitered Two pair of splice plates with SS6 hardware required to connect to system. Tray Width W1 W2 in. (mm) 6 (152) 9 (228) Fiberglass 18 (457) 24 (609) 30 (762) 12" Radius (305) 24" Radius (609) 36" Radius (914) in. (mm) * Insert radius (12", 24” or 36") in. (mm) 9 (228) (Prefix)-06-09-HT* 283/16 (716) 5913/32 (1509) 403/16 (1021) 8313/32 (2118) 523/16 (1326) 10713/32 (2728) 12 (305) (Prefix)-06-12-HT* 283/16 (716) 6213/32 (1585) 403/16 (1021) 8613/32 (2195) 523/16 (1326) 11013/32 (2804) (Prefix)-06-18-HT* 283/16 (716) 6813/32 (1737) 403/16 (1021) 9213/32 (2347) 523/16 (1326) 11613/32 (2957) 24 (609) (Prefix)-06-24-HT* 283/16 (716) 7413/32 (1890) 403/16 (1021) 9813/32 (2499) 523/16 (1326) 12213/32 (3109) 30 (762) (Prefix)-06-30-HT* 283/16 (716) 8013/32 (2042) 403/16 (1021) 10413/32 (2652) 523/16 (1326) 12813/32 (3261) 36 (914) (Prefix)-06-36-HT* 283/16 (716) 8613/32 (2195) 403/16 (1021) 11013/32 (2804) 523/16 (1326) 13413/32 (3414) 12 (305) (Prefix)-09-12-HT* 2911/16 (754) 6213/32 (1585) 4111/16 (1059) 5311/16 (1364) 11013/32 (2804) 18 (457) (Prefix)-09-18-HT* 2911/16 (754) 6813/32 (1737) 4111/16 (1059) 9213/32 (2347) 5311/16 (1364) 11613/32 (2957) 24 (609) (Prefix)-09-24-HT* 2911/16 (754) 7413/32 (1890) 4111/16 (1059) 9813/32 (2499) 5311/16 (1364) 12213/32 (3109) 4111/16 (1059) 10413/32 (2652) 5311/16 (1364) 12813/32 (3261) 18 (457) A B in. A (mm) in. B (mm) in. A (mm) in. 8613/32 (2195) B (mm) in. (mm) (Prefix)-09-30-HT* 2911/16 (754) 8013/32 (2042) 36 (914) (Prefix)-09-36-HT* 2911/16 (754) 8613/32 (2195) 4111/16 (1059) 11013/32 (2804) 5311/16 (1364) 13413/32 (3414) 18 (457) (Prefix)-12-18-HT* 313/16 (792) 6813/32 (1737) 433/16 (1097) 9213/32 (2347) 553/16 (1402) 11613/32 (2957) (Prefix)-12-24-HT* 313/16 (792) 7413/32 (1890) 433/16 (1097) 9813/32 (2499) 553/16 (1402) 12213/32 (3109) 30 (762) (Prefix)-12-30-HT* 313/16 (792) 8013/32 (2042) 433/16 (1097) 10413/32 (2652) 553/16 (1402) 12813/32 (3261) 36 (914) (Prefix)-12-36-HT* 313/16 (792) 8613/32 (2195) 433/16 (1097) 11013/32 (2804) 553/16 (1402) 13413/32 (3414) 24 (609) (Prefix)-18-24-HT* 343/16 (869) 7413/32 (1890) 463/16 (1173) 9813/32 (2499) 583/16 (1478) 12213/32 (3109) 30 (762) 12 (305) Catalog No. Mitered Fittings 24 (609) 30 (762) (Prefix)-18-30-HT* 343/16 (869) 8013/32 (2042) 463/16 (1173) 10413/32 (2652) 583/16 (1478) 12813/32 (3261) 36 (914) (Prefix)-18-36-HT* 343/16 (869) 8613/32 (2195) 463/16 (1173) 11013/32 (2804) 583/16 (1478) 13413/32 (3414) 30 (762) (Prefix)-24-30-HT* 373/16 (945) 8013/32 (2042) 493/16 (1250) 10413/32 (2652) 613/16 (1554) 12813/32 (3261) 36 (914) (Prefix)-24-36-HT* 373/16 (945) 8613/32 (2195) 493/16 (1250) 11013/32 (2804) 613/16 (1554) 13413/32 (3414) (Prefix)-30-36-HT* 403/16 (1021) 8613/32 (2195) 523/16 (1326) 643/16 (1631) 13413/32 (3414) 36 (914) 11013/32 (2804) For 3” Fittings For 6” Fittings (Radius 12” only W1 tray widths - 6” thru 18” W2 tray widths - 9” thru 24”) Polyester, Vinyl Ester All are mitered (Radius 12”, 24” & 36” W1 tray widths - 6” thru 30”) W2 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Radius 12”, 24” & 36” W1 tray widths - 6” thru 30”) W2 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered (Radius 12”, 24” & 36” W1 tray widths - 6” thru 30”) W2 tray widths - 9” thru 36”) Polyester, Vinyl Ester All radius are mitered Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-23 Page 30 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fittings Horizontal Expanding/Reducing Cross (HX) B Prefix - 18 - 12 HX 12 Radius Fitting Width2 W2 Width1 W1 To complete catalog number, insert fitting prefix. W2 R A (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. W1 Three pair of splice plates with SS6 hardware required to connect to system. Tray Width W1 W2 in. (mm) 9 (228) 12 (305) 18 (457) 24 (609) 30 (762) in. (mm) * Insert radius (12", 24” or 36") Mitered Fittings 12" Radius (305) A in. 24" Radius (609) B (mm) in. A (mm) 6 (152) (Prefix)-09-06-HX* 283/16 (716) 6 (152) (Prefix)-12-06-HX* 283/16 (716) 6213/32 (1585) 9 (228) (Prefix)-12-09-HX* 2911/16 (754) 6213/32 (1585) 6 (152) (Prefix)-18-06-HX* 283/16 (716) 6813/32 (1737) 9 (228) (Prefix)-18-09-HX* 2911/16 (754) 6813/32 (1737) 12 (305) (Prefix)-18-12-HX* 313/16 (792) 6813/32 (1737) 6 (152) (Prefix)-24-06-HX* 283/16 (716) 7413/32 (1890) 9 (228) (Prefix)-24-09-HX* 2911/16 (754) 7413/32 (1890) 12 (305) (Prefix)-24-12-HX* 313/16 (792) 7413/32 (1890) 18 (457) (Prefix)-24-18-HX* 343/16 (869) 7413/32 (1890) 6 (152) (Prefix)-30-06-HX* 283/16 8013/32 (2042) (716) 5913/32 (1509) in. 36" Radius (914) B (mm) 403/16 (1021) in. A (mm) 8313/ 32 (2118) in. B (mm) 523/16 (1326) in. (mm) 10713/32 (2728) 403/16 (1021) 8613/32 (2195) 523/16 (1326) 11013/32 (2804) 4111/16 (1059) 8613/32 (2195) 5311/16 (1364) 11013/32 (2804) 403/16 (1021) 9213/32 (2347) 523/16 (1326) 11613/32 (2957) 4111/16 (1059) 9213/32 (2347) 5311/16 (1364) 11613/32 (2957) 433/16 (1097) 9213/32 (2347) 553/16 (1402) 11613/32 (2957) 403/16 (1021) 9813/32 (2499) 523/16 (1326) 12213/32 (3109) 4111/16 (1059) 9813/32 (2499) 5311/16 (1364) 12213/32 (3109) 433/16 (1097) 9813/32 (2499) 553/16 (1402) 12213/32 (3109) 463/16 (1173) 9813/32 (2499) 583/16 (1478) 12213/32 (3109) 403/16 (1021) 523/16 (1326) 12813/32 (3261) 10413/32 (2652) 9 (228) (Prefix)-30-09-HX* 2911/16 (754) 8013/32 (2042) 4111/16 (1059) 10413/32 (2652) 5311/16 (1364) 12813/32 (3261) 12 (305) (Prefix)-30-12-HX* 313/16 (792) 8013/32 (2042) 433/16 (1097) 10413/32 (2652) 553/16 (1402) 12813/32 (3261) 18 (457) (Prefix)-30-18-HX* 343/16 (869) 8013/32 (2042) 463/16 (1173) 10413/32 (2652) 583/16 (1478) 12813/32 (3261) 24 (609) (Prefix)-30-24-HX* 373/16 (945) 8013/32 (2042) 493/16 (1250) 10413/32 (2652) 613/16 (1554) 12813/32 (3261) 6 (152) (Prefix)-36-06-HX* 283/16 (716) 8613/32 (2195) 403/16 (1021) 11013/32 (2804) 523/16 (1326) 13413/32 (3414) 9 (228) (Prefix)-36-09-HX* 2911/16 (754) 8613/32 (2195) 4111/16 (1059) 11013/32 (2804) 5311/16 (1364) 13413/32 (3414) 12 (305) (Prefix)-36-12-HX* 313/16 (792) 8613/32 (2195) 433/16 (1097) 11013/32 (2804) 553/16 (1402) 13413/32 (3414) 18 (457) (Prefix)-36-18-HX* 343/16 (869) 8613/32 (2195) 463/16 (1173) 11013/32 (2804) 583/16 (1478) 13413/32 (3414) 24 (609) (Prefix)-36-24-HX* 373/16 (945) 8613/32 (2195) 493/16 (1250) 11013/32 (2804) 613/16 (1554) 13413/32 (3414) 30 (762) (Prefix)-36-30-HX* 403/16 (1021) 8613/32 (2195) 523/16 (1326) 643/16 (1631) 13413/32 (3414) 11013/32 (2804) For 3” Fittings For 6” Fittings (Radius 12” only W1 tray widths - 9” thru 24” W2 tray widths - 6” thru 18”) Polyester, Vinyl Ester All are mitered (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) W2 tray widths - 6” thru 30”) Polyester, Vinyl Ester All radius are mitered For 4” Fittings For 8” Fittings (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) W2 tray widths - 6” thru 30”) Polyester, Vinyl Ester All radius are mitered (Radius 12”, 24” & 36” W1 tray widths - 9” thru 36”) W2 tray widths - 6” thru 30”) Polyester, Vinyl Ester All radius are mitered Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-24 Page 31 of 113 Eaton Fiberglass 36 (914) Catalog No. Mitered SPEC SHEET BLINE Fiberglass - Fittings Vertical Bends 90° (VO) (VI) One pair of splice plates with SS6 hardware required to connect to system. Vertical Outside Bend Vertical Inside Bend B VO VI A R R A B 90˚ (VI) Mitered 90˚ (VO) Mitered Prefix - 06 - 90 VO 24 Prefix - 06 - 90 VI 24 Radius Fitting Angle Width To complete catalog number, insert fitting prefix. Radius Fitting Angle Width To complete catalog number, insert fitting prefix. (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. -RBend Radius in. (mm) Fiberglass 12 (305) 24 (609) 36 (914) Tray Width in. (mm) 90˚ Mitered VO & VI Bend Catalog No. A in. / (mm) B in. / (mm) 6 (152) (Prefix)-06-90(*)12 9 (228) (Prefix)-09-90(*)12 For 3” Fittings 12 (305) (Prefix)-12-90(*)12 18 (457) (Prefix)-18-90(*)12 24 (609) (Prefix)-24-90(*)12 (Radius 12” only • Tray widths - 6” thru 24”) Polyester, Vinyl Ester All are mitered 30 (762) (Prefix)-30-90(*)12 36 (914) (Prefix)-36-90(*)12 6 (152) (Prefix)-06-90(*)24 9 (228) (Prefix)-09-90(*)24 12 (305) (Prefix)-12-90(*)24 18 (457) (Prefix)-18-90(*)24 24 (609) (Prefix)-24-90(*)24 30 (762) (Prefix)-30-90(*)24 36 (914) (Prefix)-36-90(*)24 6 (152) (Prefix)-06-90(*)36 9 (228) (Prefix)-09-90(*)36 12 (305) (Prefix)-12-90(*)36 18 (457) (Prefix)-18-90(*)36 24 (609) (Prefix)-24-90(*)36 30 (762) (Prefix)-30-90(*)36 36 (914) (Prefix)-36-90(*)36 275⁄32 275⁄32 (690) (690) For 4” Fittings (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered 3623⁄32 3623⁄32 (933) (933) For 6” Fittings (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered For 8” Fittings 4429⁄32 4429⁄32 (1141) (1141) (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered (*) Insert ‘VO’ for Vertical Outside Bend or ‘VI’ for Vertical Inside Bend. Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-25 Page 32 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Fittings Vertical Outside Bend Vertical Inside Bend One pair of splice plates with SS6 hardware required to connect to system. Vertical Bends 45° (VO) (VI) VI VO B C A C R A C C R B 45˚ (VO) Mitered 45˚ (VI) Mitered Prefix - 06 - 45 VI 24 Prefix - 06 - 45 VO 24 Radius Fitting Angle Width To complete catalog number, insert fitting prefix. Radius Fitting Angle Width To complete catalog number, insert fitting prefix. (Prefix) See page M-16 for catalog number prefix. Dimensions for reference only, when critical contact factory. 45˚ Mitered -RBend Radius in. mm 12 (305) 36 (914) A B C in. / (mm) in. / (mm) in. / (mm) Catalog No. in. mm 6 (152) (Prefix)-06-45(*)12 9 (228) (Prefix)-09-45(*)12 12 (305) (Prefix)-12-45(*)12 18 (457) (Prefix)-18-45(*)12 24 (609) (Prefix)-24-45(*)12 30 (762) (Prefix)-30-45(*)12 For 4” Fittings 36 (914) (Prefix)-36-45(*)12 6 (152) (Prefix)-06-45(*)24 9 (228) (Prefix)-09-45(*)24 (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered 12 (305) (Prefix)-12-45(*)24 18 (457) (Prefix)-18-45(*)24 24 (609) (Prefix)-24-45(*)24 30 (762) (Prefix)-30-45(*)24 36 (914) (Prefix)-36-45(*)24 6 (152) (Prefix)-06-45(*)36 9 (228) (Prefix)-09-45(*)36 12 (305) (Prefix)-12-45(*)36 18 (457) (Prefix)-18-45(*)36 24 (609) (Prefix)-24-45(*)36 30 (762) (Prefix)-30-45(*)36 36 (914) (Prefix)-36-45(*)36 For 3” Fittings 231⁄16 99⁄16 131⁄2 (585) (242) (343) 231⁄16 99⁄16 131⁄2 (585) (242) (343) (Radius 12” only Tray widths - 6” thru 24”) Polyester, Vinyl Ester All are mitered Fiberglass 24 (609) VO & VI Bend Tray Width For 6” Fittings (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered For 8” Fittings 231⁄16 99⁄16 131⁄2 (585) (242) (343) (Radius 12”, 24” & 36” Tray widths - 6” thru 36”) Polyester, Vinyl Ester All radius are mitered (*) Insert ‘VO’ for Vertical Outside Bend or ‘VI’ for Vertical Inside Bend. 60˚ and 30˚ vertical bends available in mitered construction. Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-26 Page 33 of 113 Eaton SPEC SHEET BLINE Fiberglass - Covers & Cover Accessories Covers Material Thickness: .090" (2.3) Cover Length: 10' (3m) Standard Mounting Hardware: (10 each) #10 x 3⁄4" stainless, self drilling screws provided with each section Peaked Cover provides 1 to 3.7 pitch Peaked covers available for straight sections only. No Hardware provided. Covers F C - 24 - 120 Length or fitting description Width Rail design Material F FV FP FVP C C C C - 24 24 24 24 - 120 120 120 120 = = = = Flat polyester Flat vinyl ester Peaked polyester Peaked vinyl ester Quantity of Standard Cover Clamps Required Straight Section 60" or 72" ............................................ 4 pcs. Straight Section 120" or 144" ...................................... 6 pcs. Horizontal/Vertical Bends .............................................. 4 pcs. Tees .......................................................................................... 6 pcs. Crosses .................................................................................. 8 pcs. Note: When using the Heavy Duty Cover Clamp, only one-half the number of clamps stated above is required. Standard Cover Clamp • Furnished in pairs with hardware. Catalog No. Side Rail Height 9(Δ)-9013 9(Δ)-9014 9(Δ)-9016 Heavy Duty Cover Clamp Catalog No. Recommended for outdoor service. • W = tray width • Heavy duty cover clamp available for flat covers only in. (mm) 3 4 6 (101) in. 3 4 6 8 Catalog No. (mm) (76) (101) (152) (203) Side Rail Height • W = tray width in. 9F-W-9034P 9F-W-9044P 9F-W-9064P 9F-W-9084P Fiberglass (152) Side Rail Height 9F-W-9034 9F-W-9044 9F-W-9064 9F-W-9084 Peaked Cover Clamp (76) 3 4 6 8 (mm) (76) (101) (152) (203) Thermo Plastic Drive Rivet • Sold individually. • Shipped in packages of 25 pcs. Catalog No. TPDR Material Designations (Δ) Insert one of the following material designations when required. F = Polyester Resin (Example: 9F-9013) available for all side rail heights FV = Vinyl Ester Resin (Example: 9FV-9013) available for all side rail heights Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-27 Page 34 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Accessories Example: 316 Stainless Steel SS6 Hardware Option Part Number with Hardware Explanation Note: All hardware is 3/8” 9F-4004 SS6: pair of 4-hole splice plates for 4" (101) system with stainless steel hardware 9FV-8006 SS6: pair of 8-hole vinyl ester splice plates for 6" (152) system with stainless steel hardware Standard Lay-In Splice Plates Material • Furnished in pairs with 316 stainless steel hardware • One pair including hardware provided with straight section. (Expansion splice quantity subtracted) Height Catalog No. in. (mm) 3" 4" 6" 8" Fiberglass Expansion Lay-In Splice Plates Material (76) (101) (152) (203) Height 9(Δ)-4003SS6 9(Δ)-4004SS6 9(Δ)-8006SS6 9(Δ)-8008SS6 Catalog No. in. (mm) • Furnished in pairs with 316 stainless steel hardware 3" 4" 6" 8" Fiberglass (76) (101) (152) (203) 9(Δ)-4013SS6 9(Δ)-4014SS6 9(Δ)-8016SS6 9(Δ)-8018SS6 Tray to Box Splice Plates These plates are used to attach the end of a tray run to a distribution box or control center. • Furnished in pairs with 316 stainless steel hardware Material Height Catalog No. in. (mm) 3" 4" 6" 8" Fiberglass Step Down Splice Plates Material These plates are offered for connecting cable tray sections having side rails of different heights. • Furnished in pairs with 316 stainless steel hardware Fiberglass (203) Height Catalog No. in. (mm) 8” to 6” 8” to 4” 6” to 3” 6” to 4” 4” to 3” (203 to 152) Material This plate forms a closure for any tray that dead ends. • Furnished as one plate • W = tray width (152) (203 to 101) (152 to 76) (152 to 101) (101 to 76) Height 9(Δ)-4053SS6 9(Δ)-4054SS6 9(Δ)-8056SS6 9(Δ)-8058SS6 9(Δ)-8086SS6 9(Δ)-8084SS6 9(Δ)-8063SS6 9(Δ)-8064SS6 9(Δ)-4043SS6 Catalog No. in. (mm) Fiberglass 3" 4" 6" 8" (76) (101) (152) (203) 9(Δ)-1083-WSS6 9(Δ)-1084-WSS6 9(Δ)-1086-WSS6 9(Δ)-1088-WSS6 Resin Seal Kit To reseal fiberglass after field modifications. • 1 pint (473ml) Contents: Sealant and Applicator. (Δ) See page M-27 for material selection B-Line series Cable Tray Systems Resin Seal Kit Catalog No. RSK-010 Dimensions shown in parentheses are in millimeters, unless otherwise specified. M-28 Page 35 of 113 Eaton Fiberglass Blind End Plate (76) (101) SPEC SHEET BLINE Fiberglass - Accessories Horizontal Adjustable Splice Plates These plates provide for changes in the horizontal direction that do not conform to standard fittings. • Furnished in pairs with 316 stainless steel hardware • Body made from 316 stainless steel • Used for all material finishes Material Height Catalog No. in. (mm) Fiberglass 3" 4" 6" 8" 9F-4033SS6 9F-4034SS6 9F-8036SS6 9F-8038SS6 (76) (101) (152) (203) Horizontal Splice Plates • Furnished in pairs with 316 stainless steel hardware Material Height 90° Catalog No. 45° 30° 9(Δ)-4903HSS6 9(Δ)-4904HSS6 9(Δ)-8906HSS6 9(Δ)-8908HSS6 9(Δ)-4453HSS6 9(Δ)-4454HSS6 9(Δ)-8456HSS6 9(Δ)-8458HSS6 9(Δ)-4303HSS6 9(Δ)-4304HSS6 9(Δ)-8306HSS6 9(Δ)-8308HSS6 in. (mm) Fiberglass 3" 4" 6" 8" (76) (101) (152) (203) Vertical Adjustable Splice Plates These plates provide for changes in elevation that do not conform to standard vertical fittings. • Furnished in pairs with 316 stainless steel hardware Material Catalog No. in. (mm) Fiberglass Fiberglass Height 3" 4" 6" 8" (76) (101) (152) (203) 9(Δ)-4023SS6 9(Δ)-4024SS6 9(Δ)-8026SS6 9(Δ)-8028SS6 Vertical Splice Plates • Furnished in pairs with 316 stainless steel hardware Material Height in. (mm) Fiberglass 3" 4" 6" 8" (76) (101) (152) (203) (Δ) See page M-27 for material selection Eaton 90° Catalog No. 45° 30° 9(Δ)-4903VSS6 9(Δ)-4904VSS6 9(Δ)-8906VSS6 9(Δ)-8908VSS6 9(Δ)-4453VSS6 9(Δ)-4454VSS6 9(Δ)-8456VSS6 9(Δ)-8458VSS6 9(Δ)-4303VSS6 9(Δ)-4304VSS6 9(Δ)-8306VSS6 9(Δ)-8308VSS6 Dimensions shown in parentheses are in millimeters, unless otherwise specified. M-29 Page 36 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Accessories Ladder Drop-Out Specially-designed Ladder Drop-Outs provide a rounded surface with adequate radius to protect cable as it exits from the tray, preventing damage to insulation. • 4" (101) radius • W = tray width • Furnished with #10 x 3⁄4" self-drilling stainless steel screws Catalog No. 9(Δ)-1104-W Barriers • Furnished with #10 x 3⁄4" self-drilling stainless steel screws Catalog No. Side Rail Height 72(Δ)-120 73(Δ)-120 75(Δ)-120 77(Δ)-120 3" (76) 4" (101) 6" (152) 8" (203) in. (mm) Flexible Horizontal Barrier Kit One kit allows up to a 36" (914) radius position of the barrier. Kit Contents: 1 pc — 72" (1829) Straight Barrier 4 pc — 9F-9002 Barrier Strip Clip 8 pc — Thermo Plastic Drive Rivet 4 pc — #10 x 3⁄4" Stainless Steel Self-Drilling Screw Assembly required — directions included. Catalog No. Side Rail Height 72(Δ)-90HBFL 73(Δ)-90HBFL 75(Δ)-90HBFL 77(Δ)-90HBFL 3" (76) 4" (101) 6" (152) 8" (203) in. (mm) Vertical Bend Barriers • Furnished with #10 x 3⁄4" self-drilling stainless steel screws * Insert 2 for 3" (76) siderail height 3 for 4" (101) siderail height 5 for 6" (152) siderail height 7* (Δ) - 90 VO 24 Radius VI or VO Angle Material Barrier Size VO VI Clamp/Guide - Fiberglass Catalog No. 9F-1208 Fiberglass Conduit to Cable Tray Adapter Catalog No. 9FV-2008 9FV-2009 9FV-2010 9FV-2011 9FV-2012 9FV-2013 9FV-2014 9FV-2015 9FV-2016 9FV-2017 • For rigid or PVC conduit • Furnished in pairs with 316 stainless steel hardware (Δ) See page M-27 for material selection B-Line series Cable Tray Systems Conduit Size in. (mm) 0.50 0.75 1.00 1.25 1.50 2.00 2.50 3.00 3.50 4.00 (15) (20) (25) (32) (40) (50) (65) (80) (90) (100) Dimensions shown in parentheses are in millimeters, unless otherwise specified. M-30 Page 37 of 113 Eaton Fiberglass • Nonmetallic • Designed for 3⁄8" hardware - not included • Combination hold down clamp and guide • Material: Glass reinforced polyurethane • Sold in pairs SPEC SHEET BLINE Fiberglass - Cable Channel & Fittings Straight Section • Load data was interpolated from CSA testing. • Loads shown are for FCCN series. • Loads shown are for 6 ft. (1.83m) span with deflection of .7 (18.26) inches. • One pair of splice plates included with each straight section. FCC Fiberglass Cable Channel Ventilated Catalog No. Width Ventilated Non-Ventilated (*)-03-120 (*)-03-240 (*)-04-120 (*)-04-240 (*)-06-120 (*)-06-240 (*)-08-120 (*)-08-240 (*)N-03-120 (*)N-03-240 (*)N-04-120 (*)N-04-240 (*)N-06-120 (*)N-06-240 (*)N-08-120 (*)N-08-240 Length Height Load in. (mm) ft. (m) in. (mm) Lbs/Ft (kg/m) 3 3 4 4 6 6 8 8 10 20 10 20 10 20 10 20 (3) 1 1 11⁄8 11⁄8 15⁄8 15⁄8 23⁄16 23⁄16 (25) 8 (12) 8 (12) 12 (18) 12 (18) 58 (86) 58 (86) 87 (129) 87 (129) (76) (76) (101) (101) (152) (152) (203) (203) (6) (3) (6) (3) (6) (3) (6) (25) (28) (28) (35) (35) (55) (55) FCCN Fiberglass Cable Channel Non-Ventilated Cable Channel Fittings Fiberglass All fittings are of mitered construction with 12" (305) radius. Horizontal 3" series 4" series 6" series 8" series 90˚ 45˚ (*)N-03-90HB12 (*)N-03-45HB12 (*)N-04-90HB12 (*)N-04-45HB12 (*)N-06-90HB12 (*)N-06-45HB12 (*)N-08-90HB12 (*)N-08-45HB12 One pair of splice plates included. VO Vertical 3" series 4" series 6" series 8" series 90˚ 45˚ (*)N-03-90V*12 (*)N-03-45V*12 (*)N-04-90V*12 (*)N-04-45V*12 (*)N-06-90V*12 (*)N-06-45V*12 (*)N-08-90V*12 (*)N-08-45V*12 One pair of splice plates included. (*) Insert material type FCC for Polyester Resin - available for all widths FCCV for Vinyl Ester Resin - available for all widths VI Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Eaton M-31 Page 38 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Cable Channel Fittings & Accessories Horizontal Tees Catalog No. • Two pair of splice plates included. Width in. (mm) FCC(*)N-03-HT12 FCC(*)N-04-HT12 FCC(*)N-06-HT12 FCC(*)N-08-HT12 3 4 6 8 (76) (101) (152) (203) All fittings are of mitered construction with 12" (305) radius. (*) See page fitting material selection bottom of page M-31 Horizontal Crosses Catalog No. • Three pair of splice plates included. Width in. (mm) FCC(*)N-03-HX12 FCC(*)N-04-HX12 FCC(*)N-06-HX12 FCC(*)N-08-HX12 3 4 6 8 (76) (101) (152) (203) All fittings are of mitered construction with 12" (305) radius. (*) See page fitting material selection bottom of page M-31 Splice Plates • Sold in pairs - included with tray sections. • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1001SS6 Expansion Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1013SS6 Horizontal 90˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. Horizontal 45˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1451HSS6 Horizontal 30˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1301HSS6 Splice plates included with cable channel sections. Hardware for splice plates is 1/4”-20 (316SS). (Δ) See page M-27 for material selection B-Line series Cable Tray Systems Dimensions shown in parentheses are in millimeters, unless otherwise specified. M-32 Page 39 of 113 Eaton Fiberglass 9(Δ)-1901HSS6 SPEC SHEET BLINE Fiberglass - Cable Channel Accessories Horizontal 90˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1901VSS6 Horizontal 45˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware 90 Catalog No. 9(Δ)-1451VSS6 a 2 Horizontal 30˚ Splice Plates • Sold in pairs • Uses 1/4”-20 316SS hardware Catalog No. 9(Δ)-1301VSS6 Horizontal Adjustable Splice Plates • Sold per piece • Uses 3/8”-16 316SS hardware Catalog No. 9(Δ)-1023SS6 Vertical Adjustable Splice Plates • Sold per piece • Uses 3/8”-16 316SS hardware • Body made from 316 stainless steel • Used for all material finishes Catalog No. Fiberglass 9F-1033SS6 Expansion Guide Clamp Catalog No. • Sold per clamp • Order 1/2" hardware separately 9SS6-1248-3 9SS6-1248-4 9SS6-1248-6 9SS6-1248-8 Width in. (mm) 3 4 6 8 (76) (101) (152) (203) Hold-Down Clamp • Sold per clamp • Order 1/2" hardware separately Catalog No. 9SS6-1247-3 9SS6-1247-4 9SS6-1247-6 9SS6-1247-8 Green = Fastest shipped items (Δ) See page M-27 for material selection Eaton Black = Normal lead-time items Width in. (mm) 3 4 6 8 (76) (101) (152) (203) Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. M-33 Page 40 of 113 B-Line series Cable Tray Systems SPEC SHEET BLINE Fiberglass - Appendix Marine Rung Cable Tray/Fiberglass Features: • For Coast Guard Requirements - Allows stainless steel banding of cables - 5/32" (15.9) slots 1” (25.4) on centers - Accommodates up to 5/8" (15.9) banding • Has applications on land - Vertical installation - Any location where extra cable positioning is required • Designed for Earton’s B-Line series Fiberglass Cable Trays • Part Number Indication - Add MR after rung spacing - Example: 46F09MR-36-240 Rung design provides: - 2" (50.8) cable support surface - Both mechanical and adhesive rung to side rail connection Fiberglass 1" (25.4) 1" (25.4) 1/ 4 " (6.3) 1" (25.4) 2" (50.8) Dimensions shown in parentheses are in millimeters, unless otherwise specified. B-Line series Cable Tray Systems M-34 Page 41 of 113 Eaton SPEC SHEET BLINE Fiberglass Materials Fiberglass We offer two fire retardant (FR) resins for strut systems: polyester and vinyl ester. Both resins are ideal for corrosive environments. While polyester is sufficient for most uses, vinyl ester is suitable for a broader range of environments. Please refer to the "Corrosion Resistance Guide" for specific applications, page 225. Materials & Finishes Our Fiberglass Strut systems are manufactured from glass fiber-reinforced plastic shapes that meet ASTM E-84, Class 1 Flame Rating and self-extinguishing requirements of ASTM D-635. A surface veil is applied during pultrusion to ensure a resin-rich surface and ultraviolet resistance. Fittings The following dimensions apply to all fittings except as noted on the drawings: Hole Size – 13/32” (10.3 mm) Dia. Hole Spacing – 13/16” (20.6 mm) from end and 17/8” (47.6 mm) on center. Width – 15/8” (41.3 mm) Thickness – 1/4” (6.3 mm) Metric Metric dimensions are shown in parentheses. Unless noted, all metric dimensions are in millimeters. Eaton 224 Page 42 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass Channel Resin Information We offer two fire retardant (FR) resins for strut systems, polyester and vinyl ester. Both resins are ideal for corrosive environments. While polyester is sufficient for most uses, vinyl ester is suitable for a broader range of environments. Please refer to the "Corrosion Resistance Guide" below for specific applications. Corrosion Resistance Guide Chemicals 70°F (21°C) 160°F (71°C) Chemicals 70°F (21°C) 160°F (71°C) Acetic acid 5% Acetic acid 52% Aluminum potassium sulfate 5% Ammonium hydroxide 10% Ammonium nitrate Benzene sulfonic acid 5% Calcium chloride Carbon tetrachloride Chlorine dioxide 15% Chromic acid 5% Copper sulfate Diesel fuel Ethylene glycol Fatty acids 100% Ferrous sulfate Fluosilicic acid 0-20% Gasoline Hydrochloric acid 1% Hydrochloric acid 15% Hydrochloric acid 37% Kerosene Magnesium chloride BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFV BFP/BFV BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV Methyl alcohol 10% Naphtha Nitric acid 5% Nitric acid 20% Phosphoric acid 10% Phosphoric acid 30% Phosphoric acid 85% Sodium bicarbonate 10% Sodium bisulfate Sodium carbonate Sodium chloride Sodium hydroxide 1-50% Sodium hypochlorite 5% Sodium nitrate Sodium silicate Sodium sulfate Sulfuric acid 0-30% Sulfuric acid 30-50% Sulfuric acid 50-70% Trisodium phosphate 25% Trisodium phosphate-All Water, Distilled BFP/BFV BFP/BFV BFP/BFV BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFV BFV BFP/BFV BFV BFP/BFV BFP - BFP parts recommended BFV - BFV parts recommended ** ** ** ** ** ** ** BFV-150° BFP/BFV BFP/BFV BFV-120° BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFP/BFV BFV BFP/BFV BFV-120° BFV-120° BFP/BFV BFV-210° BFP/BFV BFP/BFV BFV BFV-180° BFV-210° BFV-210° BFP/BFV ** Fiberglass Materials BFP/BFV BFV-210° BFP/BFV BFV-150° BFP/BFV BFP/BFV BFP/BFV BFV-100° BFV-150° BFV-150° BFP/BFV BFV BFP/BFV BFP/BFV BFP/BFV BFV BFV BFP/BFV BFV-180° BFV-150° BFP/BFV BFP/BFV ** ** ** ** ** ** ** ** - Not recommended to exceed this temperature Information contained in this chart is based on data from raw material suppliers. Temperatures are not the minimum nor the maximum (except where specifically stated) but represent standard test conditions. The products may be suitable at higher temperatures but individual test data should be required to establish suitability. The recommendations or suggestions contained in this chart are made without guarantee or representation as to results. We suggest that you evaluate the recommendations and suggestions in your own laboratory or actual field trial prior to use. Flame Retardant Properties Recommended Guideline: Temperature Design Load Multiplier 75°F (24°C) 100% 100°F (38°C) 90% 125°F (52°C) 78% 150°F (66°C) 68% 175°F (79°C) 60% 200°F (93°C) 52% Flame Resistance (FTMS 406-2023) ign/burn, seconds Intermittent Flame Test (HLT-15), rating Flammability Test (ASTM D635) Ignition Burning Time Surface Burning Characteristics (ASTM E84), Flame spread index UL 94 Flame Class BFP BFV 75/75 100 75/75 100 none 0 sec. none 0 sec. 25 25 V-0 V-0 Reference page 224 for general fitting specifications. B-Line series strut systems 225 Page 43 of 113 Eaton SPEC SHEET BLINE Fiberglass BFP22 THRU BFV22SH • Channel lengths: 10 Ft. (3.05 m) and 20 Ft. (6.09 m) • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. BFP22H17/8 BFV22H17/8 9/16” (14.3) holes 17/8” (47.6) on centers Fiberglass Materials BFP22 BFV22 Solid Back Part No. BFP22* BFV22* BFP22H17/8* BFV22H17/8* BFP22SH* BFV22SH* Material Polyester Resin Vinyl Ester Resin Polyester Resin Vinyl Ester Resin Polyester Resin Vinyl Ester Resin Description Solid Back Solid Back Holes in Back Holes in Back Slots in Back Slots in Back Color Gray Beige Gray Beige Gray Beige BFP22SH BFV22SH 9/16” (14.3) x 7/8” (22.2) slots 2” (50.8) on centers 13/16” Weight Lbs./ft. kg/m .63 .63 .60 .60 .61 .61 (.94) (20.6) (.94) 15/8” (.89) (41.3) (.89) (.91) (.91) 1 5/ 8 ” (41.3) * Insert -10 for 10’-0” (3.05 m) length or -20 for 20’-0” (6.09 m) length BFP22A BFV22A 13/16” (20.6) • Channel Lengths: 10 Ft. (3.05 m) and 20 Ft. (6.09 m) • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. 15/8” BFP22A BFV22A Solid Back to Back Part No. BFP22A* BFV22A* Material Polyester Resin Vinyl Ester Resin Description Back To Back Back To Back Color Gray Beige (41.3) 3 1/ 4 ” (82.5) Weight Lbs./ft. kg/m 1.15 1.15 (1.71) 1 5/ 8 ” (1.71) (41.3) * Insert -10 for 10’-0” (3.05 m) length or -20 for 20’-0” (6.09 m) length Published design loads on page 227 are based on usage at 70°F (21°C) and must be reduced for continuous exposure to higher temperatures. Refer to the chart below for high temperature applications. Field Cutting Sealant Kits RSK010 • Pint Sealing Kit (473 cm3) includes sealant and brush applicator • Seals exposed fibers after field cutting • UV resistant Temperature 75°F 100°F 125°F 150°F 175°F 200°F WARNING (24°C) (38°C) (52°C) (66°C) (79°C) (93°C) Design Load Multiplier 100% 90% 78% 68% 60% 52% APPROPRIATE PROTECTIVE CLOTHING AND RESPIRATORY PROTECTION DEVICE SHOULD BE WORN WHEN FIELD CUTTING OR GRINDING FIBERGLASS. Reference page 224 for general fitting specifications. Eaton 226 Page 44 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass Beam Loading Data for Glass Reinforced Polyester Resin Beam Span in. Part No. mm Maximum Allowable Beam Load Load Lbs. kN Deflection @ Maximum Allowable Beam Load Lbs. kN Lbs. kN 1392 2259 (6.19) 928 2051 (4.13) 231 511 (1.03) 101 224 (0.45) 55 123 (0.24) 34 76 (0.15) 22 50 (0.10) 9 23 (0.04) 3 9 (0.01) (1.62) 24” (609) BFP22 BFP22A 890 1127 (3.96) 0.256 0.147 (6.50) 36” (914) BFP22 BFP22A 592 750 (2.63) 0.576 0.330 (14.63) 48” (1219) BFP22 BFP22A 443 560 (1.97) 1.024 0.587 (26.01) 60” (1524) BFP22 BFP22A 353 446 (1.57) 1.600 0.918 (40.64) (1829) BFP22 BFP22A 293 370 (1.30) 2.303 1.322 (58.49) (2438) BFP22 BFP22A 218 273 (0.97) 120” (3048) BFP22 BFP22A 172 214 (0.76) 72” 96” (2.49) (1.98) (1.64) (1.21) (0.95) (.94) (10.05) 347 767 (1.54) 153 338 (0.68) 85 188 (0.38) 53 117 (0.23) (0.15) (33.58) 35 78 4.095 (104.01) 2.350 (59.69) 17 39 (0.07) 6.398 (162.51) 3.671 (93.24) 8 19 (0.03) (3.73) (8.38) (14.91) (23.32) (3.41) (1.50) (0.83) (0.52) (0.34) (0.17) (0.08) (9.12) (2.27) (0.99) Fiberglass Materials (305) 0.064 0.037 (3.33) 1/360 Span mm 1781 (7.92) 2259 (10.05) (5.01) 1/240 Span in. BFP22 BFP22A 12” Allowable Load @ Deflection = (0.55) (0.34) (0.22) (0.10) (0.04) Beam Loading Data for Glass Reinforced Vinyl Ester Resin Beam Span Part No. in. mm 12” (305) BFV22 BFV22A 24” (609) 36” Maximum Allowable Beam Load Load Lbs. kN Deflection @ Maximum Allowable Beam Load Allowable Load @ Deflection = 1/240 Span 1/360 Span in. mm Lbs. kN Lbs. kN 2220 (9.87) 6442 (28.65) 0.071 0.039 (1.80) 1568 6442 (6.97) (29.65) 1045 5549 (24.68) BFV22 BFV22A 1109 (4.93) 3219 (14.32) 0.283 0.155 (7.19) (914) BFV22 BFV22A 738 2144 (3.28) 0.637 0.348 (16.18) 48” (1219) BFV22 BFV22A 553 1606 (2.46) 1.133 0.619 (28.78) 60” (1524) BFV22 BFV22A 441 1283 (1.96) 1.770 0.967 (44.96) (5.70) 72” (1829) BFV22 BFV22A 366 1067 (1.63) (4.74) 2.549 1.393 96” (2438) BFV22 BFV22A 273 796 (1.21) 120” (3048) BFV22 BFV22A 216 633 (0.96) (9.53) (7.14) (3.54) (2.81) (0.99) 391 2079 (1.74) 172 922 (0.76) 96 516 (0.43) 60 327 (0.26) (24.56) (64.74) (35.38) (4.65) 260 1385 (1.15) 114 613 (0.51) 63 342 (0.28) 39 216 (0.17) (1.45) 40 224 (0.18) (0.99) 25 147 (0.11) (0.65) 4.531 (115.09) 2.477 (62.91) 19 121 (0.08) 11 78 (0.05) 7.079 (179.80) 3.870 (98.30) 9 72 (0.04) 7 44 (0.02) (3.94) (8.84) (15.72) (9.25) (4.10) (2.29) (0.54) (0.32) (6.16) (2.72) (1.52) (0.96) (0.34) (0.19) Loading Information Beam Loads: The above charts list the total allowable uniform load for various simple spans based on a minimum safety factor of 2. If the load is concentrated at center span, multiply the load from the above charts by 0.5 and the corresponding deflection by 0.8. All beams should be supported in a manner to prevent rotation at supports. Long, deep beams should be tied between supports to prevent twist. For channels with holes or slots use 90% of recommended load shown in channel loading chart. Reference page 224 for general fitting specifications. B-Line series strut systems 227 Page 45 of 113 Eaton SPEC SHEET BLINE Fiberglass BFP42 thru BFV42SH • Channel lengths: 10 Ft. (3.05 m) and 20 Ft. (6.09 m) • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. Fiberglass Materials BFP42 BFV42 Solid Back Part No. BFP42* BFV42* BFP42H17/8* BFV42H17/8* BFP42SH* BFV42SH* Material Polyester Resin Vinyl Ester Resin Polyester Resin Vinyl Ester Resin Polyester Resin Vinyl Ester Resin BFP42SH BFV42SH 9/16” (14.3) x 7/8” (22.2) slots 2” (50.8) on centers BFP42H17/8 BFV42H17/8 9/16” (14.3) holes 17/8” (47.6) on centers Description Solid Back Solid Back Holes in Back Holes in Back Slots in Back Slots in Back Color Gray Beige Gray Beige Gray Beige 13/16” Weight Lbs./ft. kg/m .48 .48 .46 .46 .47 .47 (.71) (20.6) (.71) 1” (.68) (25.4) (.68) (.70) 15/8” (.70) (41.3) * Insert -10 for 10’-0” (3.05 m) length or -20 for 20’-0” (6.09 m) length BFP42A BFV42A 13/16” • Channel lengths: 10 Ft. (3.05 m) and 20 Ft. (6.09 m) • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. (20.6) 1” BFP42A BFV42A Solid Back to Back Part No. Material Description Color (25.4) 2” (50.8) Weight Lbs./ft. kg/m .85 .85 (1.26) 15/8” BFP42A* BFV42A* Polyester Resin Vinyl Ester Resin Back To Back Back To Back Gray Beige (41.3) (1.26) * Insert -10 for 10’-0” (3.05 m) length or -20 for 20’-0” (6.09 m) length Published design loads on page 229 are based on usage at 70°F (21°C) and must be reduced for continuous exposure to higher temperatures. Refer to the chart below for high temperature applications. Field Cutting Sealant Kits RSK010 • Pint Sealing Kit (473 cm3) includes sealant and brush applicator • Seals exposed fibers after field cutting • UV resistant Temperature 75°F 100°F 125°F 150°F 175°F 200°F WARNING (24°C) (38°C) (52°C) (66°C) (79°C) (93°C) Design Load Multiplier 100% 90% 78% 68% 60% 52% APPROPRIATE PROTECTIVE CLOTHING AND RESPIRATORY PROTECTION DEVICE SHOULD BE WORN WHEN FIELD CUTTING OR GRINDING FIBERGLASS. Reference page 224 for general fitting specifications. Eaton 228 Page 46 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass Beam Loading Data for Glass Reinforced Polyester Resin Beam Span Part No. in. mm 12” (305) BFP42 BFP42A Maximum Allowable Beam Load Load 1/240 Span 1/360 Span mm Lbs. kN Lbs. kN 841 (3.74) 2325 (10.34) 0.104 0.060 (2.64) 403 1948 (1.79) 269 1299 (1.19) (609) BFP42 BFP42A 420 1161 (1.87) 0.417 0.239 (10.59) 100 486 (0.44) 66 323 (0.29) 36” (914) BFP42 BFP42A 279 773 (1.24) 0.938 0.537 (23.82) (0.19) 29 142 (0.13) (13.64) 43 214 48” (1219) BFP42 BFP42A 208 578 (0.92) 1.667 (42.34) 0.955 (24.26) 23 119 (0.10) 15 78 (0.06) (1524) BFP42 BFP42A 166 461 (0.74) 2.604 1.491 (66.14) 14 74 (0.06) 8 48 (0.03) (1829) BFP42 BFP42A 137 383 (0.61) 3.750 2.148 (95.25) (0.03) 5 31 (0.02) (54.56) 8 49 (2438) BFP42 BFP42A 101 284 (0.45) 6.667 (169.34) 3.818 (96.98) 3 24 (0.01) 120” (3048) BFP42 BFP42A 79 224 (0.35) 10.417 (264.59) 5.966 (151.53) – 11 72” 96” (5.16) (3.44) (2.57) (2.05) (1.70) (1.26) (0.99) (1.52) (6.07) (37.87) (8.66) (2.16) (0.95) (0.53) (0.33) (0.22) (0.10) – (0.05) (5.78) (1.43) (0.63) Fiberglass Materials 60” kN Allowable Load @ Deflection = in. 24” Lbs. Deflection @ Maximum Allowable Beam Load (0.34) (0.21) (0.14) – 14 (0.04) – – 5 (0.02) – Beam Loading Data for Glass Reinforced Vinyl Ester Resin Beam Span Part No. in. mm 12” (305) BFV42 BFV42A Maximum Allowable Beam Load Load kN Allowable Load @ Deflection = 1/240 Span 1/360 Span in. mm Lbs. kN Lbs. kN 988 (4.39) 2865 (12.74) 0.112 0.063 (2.84) 440 2278 (1.96) 293 1518 (1.30) (10.13) (609) BFV42 BFV42A 493 1431 (2.19) 0.448 0.252 (11.38) 73 378 (0.32) 36” (914) BFV42 BFV42A 328 953 (1.46) 1.009 0.566 (25.63) 31 166 (0.14) 48” (1219) BFV42 BFV42A 245 713 (1.09) 1.793 1.006 (45.54) 16 92 (0.07) 60” (1524) BFV42 BFV42A BFV42 BFV42A 195 569 162 473 (0.87) 9 57 5 37 (0.04) 1 17 (0.004) 24” Lbs. Deflection @ Maximum Allowable Beam Load (6.36) (4.24) (3.17) (2.53) (0.72) 72” (1829) 96” (2438) BFV42 BFV42A 120 351 (0.53) 120” (3048) BFV42 BFV42A 94 278 (0.42) (2.10) (1.56) (1.23) (1.60) 109 568 (0.48) 48 251 (0.21) 26 139 (0.11) 2.802 (71.17) 1.572 (39.93) 4.035 (102.49) 2.264 (57.50) 15 87 9 58 (0.06) 7.173 (182.19) 4.025 (102.23) 3 29 (0.01) 11.207 (284.66) 6.288 (159.71) – 14 (6.40) (14.37) (25.55) (2.52) (1.11) (0.62) (0.38) (0.04) (0.26) (0.13) – (0.06) – 7 (6.75) (1.68) (0.74) (0.41) (0.25) (0.02) (0.16) (0.07) – (0.03) Loading Information Beam Loads: The above charts list the total allowable uniform load for various simple spans based on a minimum safety factor of 2. If the load is concentrated at center span, multiply the load from the above charts by 0.5 and the corresponding deflection by 0.8. All beams should be supported in a manner to prevent rotation at supports. Long, deep beams should be tied between supports to prevent twist. For channels with holes or slots use 90% of recommended load shown in channel loading chart. Reference page 224 for general fitting specifications. B-Line series strut systems 229 Page 47 of 113 Eaton SPEC SHEET BLINE Fiberglass BFV501 Series U-Bolts with Hex Nuts • • • • • Design Load Safety Factor of 3 Load A: Straight down loading Load B: Side loading Inner surface of U-Bolt is flat to provide additional contact surface area Material: Glass reinforced polyurethane Load A Fiberglass Materials Load B Part No. Nominal Pipe Size in. Thread Size Design Load A mm Design Load B Maximum Torque Wt./C Lbs. kN Lbs. kN in.-Lbs. N•m Lbs. kg BFV501-1/2 1/2 (15) 3/8”-16 300 (1.33) 150 (.67) 30 (3.4) 3.5 (1.59) BFV501-3/4 3/4 (20) 3/8”-16 300 (1.33) 150 (.67) 30 (3.4) 3.9 (1.77) 1 (25) 3/8”-16 300 (1.33) 150 (.67) 30 (3.4) 4.4 (1.99) BFV501-1 BFV501-11/4 11/4 (32) 3/8”-16 300 (1.33) 150 (.67) 30 (3.4) 4.8 (2.18) BFV501-11/2 11/2 (40) 3/8”-16 300 (1.33) 150 (.67) 30 (3.4) 5.2 (2.36) BFV501-2 BFV501-21/2 BFV501-3 BFV501-31/2 BFV501-4 (50) 1/2”-13 600 (2.67) 200 (.89) 60 (6.8) 7.7 (3.49) 21/2 (65) 1/2”-13 600 (2.67) 200 (.89) 60 (6.8) 10.2 (4.63) 3 (80) 1/2”-13 600 (2.67) 200 (.89) 60 (6.8) 12.6 (5.71) 31/2 (90) 1/2”-13 600 (2.67) 200 (.89) 60 (6.8) 15.1 (6.85) 1/2”-13 600 (2.67) 200 (.89) 60 (6.8) 17.6 (7.98) 2 4 (100) Channel Nuts • Design Load Safety Factor of 3 • Overall Nut Height 5/8” (15.9) • Maximum torque and slip resistance loads shown are when using stainless steel bolts. When using fiberglass hardware use Max. Torque for fiberglass bolts, and multiply slip resistance loads by .14 for 3/8”-16 and .60 for 1/2”-13 thread size. • Material: Glass reinforced polyurethane • Spring Material: Zinc plated steel Part No. With Spring W/O Spring Pull-Out W/O (Without) Spring With Spring Thread Size Lbs kN Slip Resistance Lbs. N in.-Lbs. Max. Torque N•m Lbs. Wt./C kg BFV-224 BFV-224WO 1/4”-20 300 (1.33) 150 (.67) 200 (22.6) 2.4 (1.09) BFV-223 BFV-223WO 5/16”-18 300 (1.33) 150 (.67) 200 (22.6) 2.5 (1.13) BFV-228 BFV-228WO 3/8”-16 300 (1.33) 150 (.67) 200 (22.6) 2.3 (1.04) BFV-225 BFV-225WO 1/2”-13 300 (1.33) 150 (.67) 200 (22.6) 2.1 (0.95) Reference page 224 for general fitting specifications. Eaton 230 Page 48 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFVHHCS Hex Head Cap Screws • Design Load Safety Factor of 3 • Material: Glass reinforced polyurethane Part No. Thread Size Design Load (in tension) Max. Torque Wt./C kN in.-Lbs. N•m Lbs. kg 5/16”-18 190 (.84) 30 (3.4) .4 (.18) BFVHHCS 5/16 x 11/4 5/16”-18 190 (.84) 30 (3.4) .5 (.23) BFVHHCS 5/16 x 11/2 5/16”-18 190 (.84) 30 (3.4) .6 (.27) BFVHHCS 5/16 x 2 5/16”-18 190 (.84) 30 (3.4) .8 (.36) 3/8”-16 300 (1.33) 45 (5.1) .9 (.41) BFVHHCS 3/8 x 11/4 3/8”-16 300 (1.33) 45 (5.1) 1.1 (.50) BFVHHCS 3/8 x 11/2 3/8”-16 300 (1.33) 45 (5.1) 1.3 (.59) BFVHHCS 3/8 x 2 3/8”-16 300 (1.33) 45 (5.1) 1.3 (.59) 3/8”-16 300 (1.33) 45 (5.1) 1.5 (.68) BFVHHCS 1/2 x 1 1/2”-13 490 (2.18) 110 (12.4) 1.4 (.63) BFVHHCS 1/2 x 11/4 1/2”-13 490 (2.18) 110 (12.4) 1.8 (.81) BFVHHCS 1/2 x 11/2 1/2”-13 490 (2.18) 110 (12.4) 2.2 (1.00) BFVHHCS 1/2 x 2 1/2”-13 490 (2.18) 110 (12.4) 3.0 (1.36) 1/2”-13 490 (2.18) 110 (12.4) 3.7 (1.68) 1/2”-13 490 (2.18) 110 (12.4) 4.5 (2.04) BFVHHCS BFVHHCS BFVHHCS BFVHHCS 5/16 3/8 3/8 1/2 x1 x1 x x 21/2 21/2 BFVHHCS 1/2 x 3 Fiberglass Materials Lbs. BFVHN Hex Nuts • 3/4” & 1” sizes are available. Contact inside sales for details • Material: Glass reinforced polyurethane Part No. BFVHN 5/16 Thread Size Nut Thickness Wt./C in. mm Lbs. kg 5/16”-18 17/64 (6.7) .2 (.09) 3/8 3/8”-16 21/64 (8.3) .3 (.13) BFVHN 1/2 1/2”-13 7/16 (11.1) .7 (.32) BFVHN 5/8 5/8”-11 35/64 (13.9) 1.4 (.63) BFVHN Reference page 224 for general fitting specifications. B-Line series strut systems 231 Page 49 of 113 Eaton SPEC SHEET BLINE Fiberglass BFVATR All Threaded Rod • Design Load Safety Factor of 3 • Design Load can be increased by 40% if a second ATR nut is used. • Use ATR nuts in place of hex nuts with 3/8”-16 and 1/2”-13 threaded rod in order to obtain minimum required thread engagement of 17/32” (13.5) to obtain design load shown below. • Material: Glass reinforced vinyl ester Fiberglass Materials Part No. Lbs. kN Max. Torque Wt./Ft. in.-Lbs. N•m Lbs. kg x 48” 3/8”-16 350 (1.55) 48 (5.4) .08 (.04) BFVATR 1/2 x 48” 1/2”-13 650 (2.89) 96 (10.8) .13 (.06) BFVATR 5/8 x 48” 5/8”-11 1000 (4.45) 192 (21.7) .21 (.09) BFVATR 3 /8 Design Load (in tension) Thread Size BFVATRHN Threaded Rod Nuts • ATR Nut is required with 3/8”-16 and 1/2”-13 ATR to provide additional thread engagement which is critical to ATR load carrying capacity. • Material: Glass reinforced polyurethane H Part No. Thread Size H Wt./C in. mm BFVATRHN 3/8 3/8”-16 3/4 BFVATRHN 1/2 1/2”-13 7/8 Lbs. kg (19) .8 (.36) (22) 1.7 (.77) BFVFW Flat Washers BFV655 Series Rod Couplings • Material: PVC • Material: Glass reinforced polyurethane Part No. Hole Size Wt./C in. Lbs. kg BFVFW 3/8 3 /8 .5 (.22) Part Thread 1/ 2 BFVFW BFVFW 5/8 1 /2 (.22) Size 5 /8 .5 .5 No. (.22) BFV655-3/8 BFVFW 3/4 3 /4 .5 (.22) 1 .5 (.22) BFV655-1/2 BFV655-5/8 BFVFW 1 Wt./C Lbs. kg 3/8”-16 7.4 (3.35) 1/2”-13 11.3 16.7 (5.12) 5/8”-11 (7.57) BFVSL Series Stop-Lock Kits • Material: Glass Reinforced Polyurethane Part Thread No. Size Lbs. Wt./C kg BFVSL-3/8 3/8”-16 7.4 (3.35) BFVSL-1/2 1/2”-13 11.3 (5.12) Reference page 224 for general fitting specifications. Eaton 232 Page 50 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFV100 thru BFV300 Adjustable Pipe Clamps • • • • • • • • Design Load Nominal Pipe Sizes Part No. in. BFV100 1/2 - 11/2 Stop-Lock Kit for vertical installation Pipe O.D. Range mm Design Load Max. Torque in. mm Lbs. kN in.-Lbs. N•m .75 - 1.90 (21.3 - 48.3) 135 (.60) 10 (1.13) BFV200 11/2 - 2 (40 - 51) 1.90 - 2.37 (48.3 - 60.3) 135 (.60) 36 (4.07) BFV300 21/2 - (63 - 76) 2.87 - 3.50 (73.0 - 88.9) 145 (.64) 36 (4.07) 3 (15- 40) Fiberglass Materials Completely Non-Metallic Adjustable to U.S. & Metric pipe diameters Fits OD Sizes 3/4” (19.0) to 31/2” (88.9) Easy To Install No special tools required Design Load Safety Factor of 3 Material: Glass reinforced polyurethane Not recommended for vertical installation without additional Stop-Lock Kit. Kit includes one square washer, channel nut and hex head cap screw. Order (Stop-Lock Kit on page 232) BFVSL-3/8 for 3/8”-16 hardware or BFVSL-1/2 for 1/2”-13 hardware. Mount kit below clamp when used in vertical strut to prevent clamp slipping. BFV2000 Series Non-Metallic Pipe Clamps • For rigid and PVC conduit. • Standard hardware includes slotted round head machine screw and square nut in 316 stainless steel • Design Load Safety Factor of 3 • Material: Glass reinforced PPO • Not recommended for vertical installation without additional Stop-Lock Kit. Kit includes one square washer, channel nut and hex head cap screw. Order (Stop-Lock Kit on page 232) BFVSL-3/8 for 3/8”-16 hardware or BFVSL-1/2 for 1/2”-13 hardware. Mount kit below clamp when used in vertical strut to prevent clamp slipping. • If non-metallic hardware is required, add N to the part number. Example: BFV2008N Part No. Nominal Pipe Size Design Load Maximum Torque in. mm Lbs. kN BFV2008 1/2 (15) 300 (1.33) 10 (1.13) BFV2009 3/4 (20) 300 (1.33) 10 (1.13) BFV2010 1 (25) 300 (1.33) 10 (1.13) BFV2011 11/4 (32) 300 (1.33) 10 (1.13) BFV2012 11/2 (40) 300 (1.33) 10 (1.13) BFV2013 BFV2014 2 21/2 (50) 300 300 (1.33) 10 10 (1.13) BFV2015 BFV2016 BFV2017 3 31/2 4 (80) 300 300 300 (1.33) 10 10 10 (1.13) (65) (90) (100) Design Load in.-Lbs. N•m (1.33) (1.33) (1.33) (1.13) (1.13) (1.13) Stop-Lock Kit for vertical installation Reference page 224 for general fitting specifications. B-Line series strut systems 233 Page 51 of 113 Eaton SPEC SHEET BLINE Fiberglass BFP2400 Series 2-Hole Pipe Clamps • Design Load Safety Factor of 3 • Material: Glass reinforced polyester Design Load 15/8” (41.3) Fiberglass Materials Pipe Size 13/32” (10.3) Hole Dia. A B Part No. BFP2400-2 Nominal Pipe Size A Design Load B in. mm in. mm in. mm Lbs. kN 2 (50) 23/8 (60) 51/2 (140) 115 (0.51) BFP2400-3 3 (80) 31/2 (89) 63/4 (171) 130 (0.58) BFP2400-4 4 (100) 41/2 (114) 73/4 (197) 150 (0.66) BFP2400-6 6 (150) 65/8 (168) 10 (254) 150 (0.66) BFV751 & BFV751J Beam Clamp 1/2”-13 x 2” (50.8) Screw • Design Load Safety Factor of 3 • BFV751J (clip included) must be used when installed on tapered flange beams. • Material: Glass reinforced polyurethane • Setscrew material: Stainless Steel 316 ASTM F593 Group 2, S4 3” BFV751 (Clamp Only) BFV751J (Clamp and Retainer Clip) (76.2) 1” (25.4) 41/4” (108.0) Part No. For Hanger Rod Size A Design Load Lbs. kN Torque ft.lbs N. m BFV751-3/8 3/8”-16 500 (2.22) 10 (13) BFV751J-3/8 3/8”-16 500 (2.22) 10 (13) BFV751-1/2 1/2”-13 500 (2.22) 10 (13) BFV751J-1/2 1/2”-13 500 (2.22) 10 (13) BFV751-5/8 5/8”-11 500 (2.22) 10 (13) BFV751J-5/8 5/8”-11 500 (2.22) 10 (13) Tapped for Hanger Rod Size A 11/8” (28.6) BFVATR3/8” & BFVATRHN (Order Separately) see page 232 Reference page 224 for general fitting specifications. Eaton 234 Page 52 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFV755 Beam Clamp 1/2”-13 x 2” (50.8) Screw 25/8” • Design Load Safety Factor of 3 • Material: Glass reinforced polyurethane • Setscrew material: Stainless Steel 316 ASTM F593 Group 2, S4 (66.7) 3” (76.2) 3/ 4” Part No. Design Load 3/8”-16 400 (1.78) 400 (1.78) BFV755-3/8 BFV755-1/2 Lbs. 1/2”-13 (19.0) Torque kN ft.lbs N. m 10 10 (13) Tapped for Hanger Rod Size A (13) Fiberglass Materials For Hanger Rod Size A BFV3104 Series Clevis Hangers • Design Load Safety Factor of 3 at 120°F (49°C). • Insulation may be required at higher temperatures. • Order hanger rod and nuts separately. • Material: Glass reinforced polyurethane for BFV3104-1 thru BFV3104-6 • Material: Glass reinforced polyester & vinyl ester for BFV3104-8 thru BFV3104-12 C C A A B B BFV3104-1 thru BFV3104-6 Nominal Pipe Size Part No. BFV3104-1 BFV3104-11/2 B Hanger Rod Size C in. mm in. mm Design Load in. mm in. mm Lbs. kN 1 (50) 1 1/ 2 (38) 41/4 (108) 11/4 (32) 1/2”-13 670 (2.98) 1/2”-13 670 (2.98) (65) 2 (51) 51/8 (130) 11/4 (32) 2 (50) 2 1/ 2 (63) 61/2 (165) 11/4 (32) 1/2”-13 730 (3.25) 10 11/2 (38) 1/2”-13 1150 (5.11) 1/2”-13 1170 (5.20) Hanger Rod Size Design Load 21/2-4 (65-100) BFV3104-6 Part No. A 11/2 BFV3104-2 BFV3104-21/2, 3, 4 BFV3104-8 thru BFV3104-12 6 63/4 (171) (150) Nominal Pipe Size in. mm 51/8 (130) 125/16 (313) A in. (254) 2 B mm in. (51) C mm 165/8 (422) in. mm Lbs. kN BF*3104-8 8 (200) 91/4 (235) 3 (76) 5/8”-11 350 (1.55) BF*3104-10 10 (250) 113/8 (289) 197/8 (505) 4 (101) 5/8”-11 450 (2.01) BF*3104-12 12 (300) 131/2 (343) 223/8 (568) 5 (127) 5/8”-11 600 (2.69) *Specify P for polyester or V for Vinyl ester. Reference page 224 for general fitting specifications. B-Line series strut systems 235 Page 53 of 113 Eaton SPEC SHEET BLINE Fiberglass BF*409 Series Brackets 6” (152mm) to 24” (609mm) Long • Design Load Safety Factor of 3 based on uniform loading • MH1 - From top of bracket to center of mounting hole • MH2 - From bottom of bracket to center of mounting hole 11/4” (31.7) To Hole Fiberglass Materials A 12” (304.8) BF*409-6 BF*409-9 BF*409-12 BF*409-18 BF*409-24 Design Load A Part No. in. mm Lbs. kN 10 13 16 22 28 (250) 1400 1000 800 675 450 (6.22) (330) (406) (559) (711) 13/32” (10.3) Dia. Mounting Holes (4.45) (3.56) 11/4” (31.7) To Hole (3.00) (2.00) * Insert P for Glass Reinforced Polyester Resin or V for Glass Reinforced Vinyl Ester Resin BF*494 Series Brackets 24” (609mm) to 36” (914mm) Long • • • • Design Load Safety Factor of 3 based on uniform loading MH1 - From top of bracket to center of mounting hole MH2 - From bottom of bracket to center of mounting hole Material: Glass reinforced vinyl ester or polyester 11/4” (31.7) To Hole A B A Part No. Design Load B in. mm in. mm Lbs. kN BF*494-24 28 (711) 23 (584) 750 (3.33) BF*494-30 34 (863) 26 (660) 750 (3.33) BF*494-36 40 (1016) 29 (736) 750 (3.33) 13/32” (10.3) Dia. Mounting Holes 11/4” (31.7) To Hole * Insert P for glass reinforced polyester resin or V for glass reinforced vinyl ester resin Reference page 224 for general fitting specifications. Eaton 236 Page 54 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFV201 Square Washer for 3/8” bolt BFV202 Square Washer for 1/2” bolt • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 15/8” 15/8” (41.3) (41.3) Fiberglass Materials 13/32” (10.3) Diameter Hole 9/16” (14.3) Diameter Hole BFV340 Two Hole Flat Plate BFV129 Two Hole Splice Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 15/8” (41.3) 31/4” (82.5) 31/2” (88.9) BFV141 Three Hole Flat Plate BFV557 Three Hole Flat Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 47/8” 53/8” (123.8) (136.5) 15/8” 15/8” (41.3) (41.3) Reference page 224 for general fitting specifications. B-Line series strut systems 237 Page 55 of 113 Eaton SPEC SHEET BLINE Fiberglass BFV341 Four Hole Splice Plate BFV342 Five Hole Flat Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 91/8” (231.8) 71/4” Fiberglass Materials (184.1) BFV140 Three Hole Flat Corner Plate BFV143 Four Hole Flat Corner Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 31/2” 31/2” (88.9) (88.9) 31/2” 53/8” (88.9) (136.5) BFV132 Five Hole Flat Cross Plate BFV133 Four Hole Flat Tee Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 53/8” 31/2” (136.5) (88.9) 53/8” (136.5) 53/8” (136.5) Reference page 224 for general fitting specifications. Eaton 238 Page 56 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFV135 Three Hole Flat Gusset Corner Plate BFV142 Four Hole Flat Gusset Corner Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 31/2” 3 1/ 2” (88.9) (88.9) 31/2” 53/8” (88.9) (136.5) Fiberglass Materials BFV337 Three Hole Flat Gusset Tee Plate BFV136 Four Hole Flat Gusset Tee Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 3 1/ 2” (88.9) 31/2” (88.9) 3 1/ 2” 5 3/ 8” (88.9) (136.5) BFV532 Five Hole Flat Gusset Tee Plate BFV334 Seven Hole Flat Gusset Cross Plate • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 91/8” (231.8) 5 3/ 8” (136.5) 5 3/ 8 ” (136.5) 53/8” (136.5) Reference page 224 for general fitting specifications. B-Line series strut systems 239 Page 57 of 113 Eaton SPEC SHEET BLINE Fiberglass BFV101 Two Hole 90° Corner Angle BFV103 Three Hole 90° Corner Angle • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 15/8” 15/8” (41.3) (41.3) 25/16” 41/8” (58.7) Fiberglass Materials (104.8) BFV104 Four Hole 90° Corner Angle BFV118 Four Hole 90° Gussetted Shelf Angle • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 31/2” 15/8” 31/2” (88.9) (41.3) (88.9) 4 1 / 8” 4 1/ 8 ” (104.8) (104.8) BFV558 Four Hole 90° Corner Angle BFV371-2G Three Hole 90° Gussetted Corner Angle • Material: Injection molded glass reinforced polyurethane • Material: Injection molded glass reinforced polyurethane 31/4” (82.5) Three Holes .400” Dia. (10.1) 21/4” (57.1) 4” (101.6) 1 5 / 8” (41.3) 15/8” (41.3) 1 5/ 8 ” (41.3) Reference page 224 for general fitting specifications. Eaton 240 Page 58 of 113 B-Line series strut systems SPEC SHEET BLINE Fiberglass BFV280SQ Post Base for BF*22 BFV281SQ Post Base for BF*22A • Material: Glass reinforced polyurethane • Material: Glass reinforced polyurethane Fiberglass Materials 3” (76.3) 3” (76.3) 5” 5” (127.0) (127.0) 5” 65/8” (168.3) (127.0) BFV650 Channel Spacer B217P Plastic Closure Strip • Spacer I.D. accommodates 3/8" rod or bolts. • Available in 10 Ft. (3.05 m) lengths. • Material: PVC 17/16” (36.5) 5/8” (15.9) Used when attaching fittings to side walls of channel. This channel spacer prevents wall compression in heavy load conditions. Reference page 224 for general fitting specifications. B-Line series strut systems 241 Page 59 of 113 Eaton