Company Business Zamil Air Conditioners was founded in 1974, and is the first major business venture in manufacturing sector for the Al Zamil group of Companies. It is also the first manufacturing unit for air conditioners to be established in Saudi Arabia. Zamil Air conditioners manufactures both consumer and central range of air conditioners and has sales operations in over 55 countries in the Middle East, Europe, America, Africa, Australia and the Far East. The company’s operations are structured into four Strategic Business Units (SBUs) supporting six in - house product and service brands as well as a number of international brands under the OEM sales. The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech. The four SBUs are: 1. Consumer Business unit supporting Classic, Cooline, GE and OEM brands for consumer range of air conditioners. 2. Unitary & Applied Business unit supporting Classic, Cooline, GE and OEM brands for commercial range of air conditioners. 3. Zamil CoolCare - service and maintenance provider. 4. Geoclima srl - independent business and supporting other SBUs for their requirement of Chillers & Double skin AHU’s. The first three SBUs - Consumer Products, Unitary & Applied Products and Zamil CoolCare direct their business operations from the corporate headquarters at Dammam, Saudi Arabia. The production facilities at Dammam are shared by Consumer Products and Unitary & Applied Products. Geoclima has its own production and functional departments located at Monfalcone, Italy. All the four SBUs, while operating independently, supplement each other’s activities in a way that makes synergy work at its best and achieve the corporate goals of increased productivity and efficiently. Factories and Productions Zamil Air Conditioners has its prime manufacturing base at Dammam, Saudi Arabia and has one speciality production facility in Italy operated by Geoclima. The company can produce up to 440,000 room air conditioners, 60,000 mini-split systems and 36,500 central air-conditioning systems per year. Quality & Product Certificates The Quality systems and policies at Zamil Air Conditioners comply with the required ISO 9001:2000 certification. Zamil Air Conditioners is the first company in Saudi Arabia to receive the SASO (Saudi Arabia’s Standard Organization) certificate for room air conditioners. Its products and services are also certified with: 1. 2. 3. 4. 5. CE (Council of European Community) UL (Underwriters Laboratory) AHAM certificate (Association of Home Appliance Manufacturers) DEMKO ETL Other awards include the prestigious Engineering Excellence Award of General Electric, and the inaugural Prince Mohammed bin Fahd Al Saud Award for Factory Safety. Our Products In addition to the consumer products such as the Room Air Conditioners (RAC) and the Mini Splits, Zamil Air Conditioners manufacturers a host of residential and commercial air conditioners. This board range extends from the concealed units up to 5 ton, the ducted splits up to 30 tons, the packaged units up to 70 tons. The single and double skin air handling units up to 130,000 CFM and the water chillers up to 487 ton cooling capacity. INDEX Contents Page Model decoding ........................................................................................................................................ 2 Unit features & options .......................................................................................................................... 2-3 Physical data ......................................................................................................................................... 4-6 Selection procedure ................................................................................................................................. 7 Performance characteristics ................................................................................................................ 7-10 Electrical data ......................................................................................................................................... 11 Dimensions ........................................................................................................................................ 12-16 Typical schematic wiring diagram ...................................................................................................... 17-19 Installation & start-up instructions .......................................................................................................... 20 Electrical ................................................................................................................................................. 21 System design ........................................................................................................................................ 21 CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS. THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 1 MODEL DECODING 1& 2 BASIC 3, 4 & 5 NOMINAL COOLING CAPACITY (MBH) 6 ELECTRICAL SUPPLY ( V-Ph-Hz ) 8 7 REFRIGERA- COMPRESSOR TYPE TION CIRCUIT CL 030 036 B : 220/240-1-50 L : 380/415-3-50 (4 WIRE) S : SINGLE 042 048 060 L : 380/415-3-50 (4 WIRE) 075 090 100 120 150 L : 380/415-3-50 (4 WIRE) COOLINE CONDENSING UNIT 180 S : SINGLE D : DUAL D : DUAL R : HERMETIC RECIPROCATING 9 MODE C : COOL ONLY H : HEAT PUMP+ 10 CONDENSER MOTOR 11 CONDENSER COIL N : NO OPTION F : STD. UNIT WITH FILTER DRYER & SIGHT GLASS K : CONDENSING UNIT WITH SYSTEMIZER** C : COPPER FIN R : F & K N : STANDARD A : ALUMINUM FIN L : LOW AMBIENT B : COATED ALUMINUM FIN N : NO OPTION U : UVM V : VOLT FREE CONTACTS* C:U&V N : NO OPTION F : STD. UNIT WITH FILTER DRYER & SIGHT GLASS K : CONDENSING UNIT WITH SYSTEMIZER** P : PDS++ R:F&K S: F&P T: K&P Q : F, K & P R : HERMETIC RECIPROCATING S : SCROLL*** S : SCROLL 220 240 300 360 + ++ * ** *** 12 13 ACCESSORIES OTHER OPTIONS Applicable for CL030 to CL220 only. Not applicable for heat pump models. Not applicable for CL030 & CL036 single phase models. To match with Double Skin air handling units only. Not applicable for CL075, CL090 & CL100 dual circuit models. UNIT FEATURES & OPTIONS A. GENERAL The COOLINE Condensing units incorporate the latest innovative technology to provide quiet, reliable performance. The wrap-around coil not only adds to the aesthetical appeal, it also gives optimum heat transfer efficiency. The access panels provide access to the compressor, fan motor and to the electrical control box. These condensing units can be combined with a wide variety of evaporator coils and blower packages to provide quiet and dependable comfort. These units can be installed on a roof or at ground level. Heat pump feature is available as an option for added comfort during cold season (for models up to CL220 only). B. UNIT ENCLOSURE All panels are of heavy gauge (G-90) galvanized steel sheet and completely weatherized for outdoor installation. Steel sheet panels are zinc coated and galvanized by the hot dip process of lock-forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked on electrostatic polyester dry powder coat. C. COMPRESSOR Hermetic reciprocating/scroll compressors are used as standard as shown in the physical data. They are provided with all the standard controls necessary for proper and safe operation. These compressors have a self-regulating crankcase heater, improved internal pressure relief valve which provides high pressure protection to the refrigerant system and vibration isolators for quiet and efficient operation. D. AIR COOLED CONDENSER 1. The large wrap-around condenser coil is of corrugated fin & tube type, constructed of enhanced copper tubes and mechanically bonded to aluminum fins. As an option to aluminum fins, coated aluminum fins or corrugated copper fins may be provided. Tube support sheets are of galvanized steel, formed to provide structural strength. Tubes are circuited to ensure minimum pressure drop and maximum heat transfer. Each coil is completely dehydrated, charged and sealed at the factory upon completion of pressure tests. 2. The fans are propeller type and direct-driven, upward discharge provided with fan grille. 3. Units are equipped with totally enclosed fan motors for greater reliability and dependable performance for many years. Inherent thermal protection is automatic reset type. 2 E. SERVICE VALVES Both suction and liquid service valves are back seating type. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a gauge pressure port for ease of checking refrigerant operating pressures. F. CONTROL PANEL The control panel design is equivalent to NEMA construction for easy access ensuring dust and weather proof construction. Internal power and control wiring is neatly routed, properly anchored and all wires identified with cable markers as per NEC standard applicable to HVAC units. The electrical controls used in the control panel are UL approved, which are reliable in operation at high ambient conditions for a long period. The electrical circuit has been carefully designed with all necessary protection and circuit elements for safe operation of the unit. G. LOW PRESSURE SWITCH Auto reset SPST switch activated by refrigerant pressure - locks out the compressor, if the refrigerant pressure falls below 25 PSIG. Also provides additional protection against evaporator freeze up due to loss of indoor airflow. H. HIGH PRESSURE SWITCH (OPTIONAL) Auto reset SPST switch activated by refrigerant pressure - locks out the compressor, if the refrigerant pressure rises above 450 PSIG. Also provides additional protection against compressor damage due to loss of outdoor airflow. I. LOW AMBIENT (OPTIONAL) Low ambient operation down to 450F using fan cycling switch. J. PUMP DOWN SOLENOID VALVE FOR COOL ONLY MODELS (OPTIONAL FOR CL075 & ABOVE) Pump down solenoid valve keeps the evaporator coil dry of liquid refrigerant. 3 PHYSICAL DATA MODEL NUMBER NOMINAL CAPACITY (TONS)* COMPRESSOR CL030 CL036 CL042 CL048 CL060 2.5 3 3.5 4 5 Type Hermetic reciprocating Quantity 1 1 1 1 1 Oil (oz) 40 40 45 70 70 167 170 Refrigerant Operating Charge (oz) + CONDENSER FAN R–22 106 Type Qty. – Diameter (inch) Nominal airflow, CFM (L/S) 120 Propeller 1–18 1–18 1–24 1–24 1–24 2300 (1085) 2300 (1085) 3650 (1723) 3650 (1723) 3650 (1723) Motor HP – RPM CONDENSER COIL 106 1/4–1100 1/3–1100 Type Corrugated fin & tube Tube Dia.- Rows - Fins Per Inch 3/8-2-16 3/8-2-16 3/8-1-16 3/8-2-16 3/8-2-16 Total face area, Sq. ft. (Sq. m.) 10 (0.929) 10 (0.929) 16 (1.49) 16 (1.49) 16 (1.49) HIGH PRESSURE SWITCH Open (PSIG) (OPTIONAL) Close (PSIG) 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 LOW PRESSURE SWITCH Open (PSIG) 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 Close (PSIG) 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 REFRIGERANT LINES** Suction line size (OD) - inch 3/4 3/4 7/8 7/8 7/8 Liquid line size (OD) - inch 3/8 3/8 3/8 3/8 1/2 Kg. 76 79 106 106 118 SHIPPING WEIGHT * Refer to performance data for exact rating values. ** Pipe sizes are for runs up to 25 feet to indoor unit. For refrigerant lines longer than 25 feet, use next larger size. + Operating system charge is applicable when matched with BL series air handling units & connected by 25 feet of refrigerant piping. 4 PHYSICAL DATA MODEL NUMBER CL075 CL075 CL090 CL090 CL100 CL100 CL120 CL120 NUMBER OF REFRIGERATION CIRCUIT Single Dual Single Dual Single Dual Single Dual 6 6 7 7 8 8 10 10 Scroll Recip. Scroll Recip. Scroll Recip. Scroll Scroll Quantity 1 2 1 2 1 2 1 2 Oil (oz) 60 40x2 81 45x2 110 70x2 110 70x2 317 152x2 352 159x2 2–24 2–24 2–24 NOMINAL CAPACITY (TONS)* COMPRESSOR Type Refrigerant Operating Charge (oz) + CONDENSER FAN R–22 210 115x2 304 155x2 Type Qty. – Diameter (inch) Propeller 2–24 2–24 2–24 2–24 2–24 Nominal airflow, CFM (L/S) 7150 (3374) 7150 (3374) 6500 (3068) 6500 (3068) 7150 (3374) 7150 (3374) 7150 (3374) 7150 (3374) Motor HP – RPM CONDENSER COIL 1/3–1100 (2) Type Tube Dia.- Rows - Fins Per Inch Corrugated fin & tube 3/8-1-16 3/8-1-16 3/8-2-16 3/8-2-16 3/8-2-16 3/8-2-16 3/8-2-16 3/8-2-16 Total face area, Sq. ft. (Sq. m.) 24 (2.23) 24 (2.23) 21 (1.95) 21 (1.95) 24 (2.23) 24 (2.23) 24 (2.23) 24 (2.23) HIGH PRESSURE SWITCH Open (PSIG) (OPTIONAL) Close (PSIG) 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 LOW PRESSURE SWITCH Open (PSIG) 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 Close (PSIG) 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 1-1/8 7/8 (2) 1-1/8 7/8 (2) 1-3/8 7/8 (2) 1-3/8 7/8 (2) Liquid line size (OD) - inch 5/8 1/2 (2) 5/8 1/2 (2) 5/8 1/2 (2) 5/8 1/2 (2) Kg. 204 235 235 230 235 235 240 241 REFRIGERANT LINES** Suction line size (OD) - inch SHIPPING WEIGHT * Refer to performance data for exact rating values. ** Pipe sizes are for runs up to 25 feet to indoor unit. For refrigerant lines longer than 25 feet, use next larger size. + Operating system charge is applicable when matched with BL series air handling units & connected by 25 feet of refrigerant piping. 5 PHYSICAL DATA MODEL NUMBER CL150 CL150 CL180 CL220 CL240 CL300 CL360 NUMBER OF REFRIGERATION CIRCUIT Single Dual Dual Dual Dual Dual Dual 12 12 15 18 20 25 30 Scroll Scroll Scroll Scroll Scroll Scroll Scroll 1 2 2 2 2 2 2 140 60 110 110 135 223 223 360 450 540 2 – 30 2 – 30 3 – 30 NOMINAL CAPACITY (TONS)* COMPRESSOR Type Quantity Oil per system (oz) Refrigerant Charge per system (oz)+ CONDENSER FAN HIGH PRESSURE SWITCH 296 161 232 Type Qty. – Diameter (inch) CONDENSER COIL R–22 251 Propeller 2 – 26 2 – 26 2 – 26 2 – 26 Nominal CFM (L/S) 10000 (4719) 10000 (4719) 12000 (5663) 12000 (5663) 13200 (6229) 13000 (6135) 19800 (9344) Motor HP – RPM 1/3 – 850 1/3 – 850 Type 3/4 – 950 3/4 – 950 1.5 – 950 1.5 – 950 1.5 – 950 Corrugated fin & tube Tube Dia.– Rows – Fins per inch 3/8–2–16 3/8–2–16 3/8–2–16 3/8–2–16 3/8–4–14 3/8–5–14 3/8–4–14 Total face area, Sq. ft. (Sq. m.) 38 (3.53) 38 (3.53) 38 (3.53) 38 (3.53) 28 (2.6) 28 (2.6) 46.66(4.33) Open (PSIG) 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 450 ± 10 Close (PSIG) 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 360 ± 15 Open (PSIG) 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 25 ± 5 Close (PSIG) 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 50 ± 5 Suction line size (OD), inch 1-3/8 7/8 1-3/8 1-3/8 1-3/8 1-3/8 1-5/8 Liquid line size (OD), inch 5/8 1/2 5/8 5/8 5/8 5/8 7/8 Kg. 400 415 535 592 750 840 950 (OPTIONAL) LOW PRESSURE SWITCH REFRIGERANT LINES** SHIPPING WEIGHT * Refer to performance data for exact rating values. ** Pipe sizes are for runs up to 50 feet to indoor unit. For refrigerant lines longer than 50 feet, use next larger size. + Operating system charge is applicable when matched with BL series air handling units & connected by 25 feet of refrigerant piping. 6 SELECTION PROCEDURE 1. Enter performance tables at specified SST and desired ambient conditions. 2. HEAT REJECTION: Calculate condenser Total Heat Rejection Capacity as follows: HR = Unit cooling capacity + (3.41 x Total Unit Power Input, Watts). 3. HEAD PRESSURE: To determine head pressure (psig) use the following conversion table: Condensing Temp. - 0F. (R-22) Head Pressure - PSIG. 100 110 120 130 140 150 160 195.9 226.4 259.9 296.9 337.3 381.6 429.8 4. CORRECTION FACTORS FOR ALTITUDE: ALTITUDE (FEET) FACTOR 2000 4000 6000 8000 10000 Condensing Unit Cooling Capacity .99 .98 .96 .95 .94 Condensing Unit & Evaporator .98 .96 .93 .90 .88 PERFORMANCE DATA MODEL : CL030, HERMETIC RECIPROCATING (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW MODEL : CL036, HERMETIC RECIPROCATING (SINGLE) COMP. 0 AMBIENT TEMPERATURE - F 75 30.30 99.00 2.47 34.10 103.00 2.56 37.90 107.50 2.7 42.00 110.00 2.86 45.90 113.50 3.06 49.10 115.00 3.2 85 27.40 109.00 2.56 31.20 113.00 2.7 34.70 116.00 2.86 37.50 118.00 3.09 42.20 121.00 3.21 46.00 124.00 3.42 95 25.00 118.00 2.65 28.50 121.00 2.8 31.80 124.00 3.03 34.30 126.00 3.31 39.10 128.50 3.4 42.40 130.50 3.61 105 22.40 126.50 2.74 25.60 129.50 2.94 28.80 132.50 3.16 31.90 134.50 3.36 35.40 136.50 3.61 38.50 138.50 3.82 115 19.90 134.50 2.84 22.60 137.50 3.05 25.40 141.00 3.36 28.50 143.00 3.5 31.50 145.00 3.8 34.90 146.50 4.04 SST (0F) 125 17.40 142.00 2.9 20.00 146.00 3.16 22.50 148.00 3.42 25.30 149.50 3.68 28.40 151.00 3.92 31.20 152.50 4.2 30 35 40 45 50 55 MODEL : CL042, HERMETIC RECIPROCATING (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 36.60 109.00 3.83 41.20 112.00 4.00 45.90 115.00 4.25 50.40 117.50 4.48 53.20 119.00 4.75 60.00 121.00 4.97 95 33.20 117.00 3.99 37.40 121.00 4.18 41.90 123.00 4.45 46.00 126.00 4.65 50.90 128.00 4.90 55.20 131.00 5.17 105 30.10 125.00 4.10 34.00 129.00 4.33 38.20 132.00 4.63 42.40 134.00 4.86 46.40 136.00 5.06 50.80 138.00 5.41 115 27.60 134.50 4.37 30.50 137.50 4.47 34.40 140.50 4.78 38.40 142.00 5.05 42.50 145.00 5.37 46.20 146.00 5.65 75 36.00 105.00 3.61 40.00 110.00 3.83 44.30 113.00 3.99 49.00 116.00 4.21 53.00 120.00 4.51 57.60 121.50 4.72 85 33.00 113.00 3.75 37.00 117.00 3.95 41.00 121.50 4.17 45.20 124.00 4.42 49.40 126.50 4.68 53.40 129.00 4.77 95 30.00 122.00 3.9 34.00 125.00 4.12 38.00 128.50 4.38 42.00 131.00 4.66 46.00 134.00 4.91 49.80 136.00 5.15 105 27.00 130.00 4.05 31.00 133.00 4.21 34.20 137.00 4.54 38.00 140.00 4.85 42.00 142.00 5.2 45.50 144.00 5.43 115 24.30 138.00 4.15 27.70 142.50 4.45 31.00 145.00 4.74 34.50 148.00 5.04 38.00 149.00 5.38 41.20 151.50 5.57 125 21.60 147.00 4.34 24.60 151.00 4.63 28.00 152.50 4.94 31.00 155.00 5.23 34.00 156.50 5.52 37.20 158.00 5.84 MODEL : CL048, HERMETIC RECIPROCATING (SINGLE) COMP. 0 75 39.60 101.00 3.70 44.50 104.00 3.87 49.00 107.00 4.03 54.10 109.00 4.37 59.20 111.00 4.50 64.20 113.00 4.71 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F SST (0F) 125 23.90 143.00 4.38 27.30 146.00 4.65 30.90 148.50 4.85 34.70 151.00 5.24 38.10 152.00 5.55 41.90 154.00 5.86 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 44.40 100.00 3.74 49.50 103.00 3.88 54.70 106.00 4.0 59.80 108.50 4.19 65.00 110.00 4.31 70.00 113.00 4.52 85 41.50 108.50 3.91 46.20 111.50 4.02 51.10 114.50 4.23 56.10 117.00 4.42 61.00 119.00 4.62 65.50 121.00 4.84 95 38.50 117.50 4.05 43.20 120.00 4.22 48.00 123.00 4.44 52.30 125.50 4.67 57.00 127.00 4.93 61.30 129.00 5.15 105 35.30 126.50 4.2 39.70 129.50 4.42 44.00 132.00 4.67 48.50 134.00 4.94 53.00 136.00 5.19 57.30 138.00 5.51 115 32.10 135.00 4.32 36.20 138.00 4.61 40.50 141.00 4.91 44.50 143.00 5.15 48.70 145.00 5.51 52.80 146.00 5.84 LEGEND: SST - Saturated Suction Temperature; TC - Total Capacity (1000 Btuh) Gross; CT - Condensing Temperature (0F); kW - Total unit power input 7 125 30.50 143.00 4.44 33.10 146.00 4.74 37.00 148.00 5.04 41.00 150.00 5.45 44.80 151.50 5.75 48.50 153.00 6.1 PERFORMANCE DATA MODEL : CL060, HERMETIC RECIPROCATING (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 51.00 104.00 4.70 56.50 108.00 5.05 62.50 110.00 5.30 68.50 113.00 5.60 74.25 116.00 5.95 80.00 118.00 6.10 85 47.50 113.00 5.05 53.50 117.00 5.40 59.00 120.00 5.70 64.50 122.00 6.00 70.50 126.00 6.35 75.75 128.00 6.60 95 44.50 121.00 5.30 50.25 125.00 5.65 55.50 129.00 6.00 61.00 131.00 6.35 66.50 134.00 6.70 72.00 136.00 7.05 105 41.50 131.00 5.60 47.00 134.00 5.90 52.25 137.00 6.30 57.50 140.00 6.70 62.50 142.00 7.05 68.00 145.00 7.50 115 38.50 140.00 5.85 43.50 143.00 6.25 48.50 146.00 6.70 53.50 147.50 7.00 58.50 149.50 7.40 63.50 152.00 7.90 125 35.50 147.50 6.10 40.50 150.00 6.50 45.25 153.00 6.90 50.00 155.00 7.10 54.50 157.00 7.70 69.50 159.00 8.20 LEGEND: SST - Saturated Suction Temperature 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 61.00 102.00 5.60 69.00 106.00 6.00 75.00 110.00 6.30 82.50 112.00 6.65 89.50 114.00 6.90 96.50 116.00 7.20 95 57.50 112.00 6.05 64.00 115.00 6.30 71.00 118.00 6.65 77.00 120.00 6.95 84.50 122.00 7.30 91.00 124.00 7.60 105 53.50 121.00 6.40 59.50 124.00 6.70 66.00 127.00 7.10 72.50 129.00 7.35 79.00 130.50 7.70 85.00 132.00 8.00 115 49.00 130.00 6.70 55.00 133.00 7.10 61.00 137.00 7.50 67.00 139.00 7.85 72.50 141.00 8.20 79.00 142.00 8.50 SST (0F) 125 45.00 140.00 7.10 50.50 143.00 7.45 56.00 145.00 7.75 61.00 147.00 8.15 67.00 149.00 8.55 72.00 150.00 8.90 30 35 40 45 50 55 MODEL : CL090, HERMETIC SCROLL (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 73.00 107.00 6.53 81.50 110.00 6.88 90.00 113.00 7.24 99.00 116.00 7.70 107.50 118.00 8.16 116.00 120.00 8.41 95 65.00 116.00 6.76 73.50 119.00 7.14 81.50 122.00 7.55 90.00 124.00 8.00 98.50 126.00 8.36 106.00 128.00 8.82 105 58.50 124.00 6.83 66.50 126.00 7.24 74.00 128.00 7.75 81.50 131.00 8.21 89.50 134.00 8.72 97.00 136.00 9.18 115 51.00 130.00 6.94 58.50 135.00 7.50 66.00 139.00 8.06 73.00 141.00 8.57 80.50 143.00 9.08 87.50 144.00 9.54 - Condensing Temperature (0F) TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 67.00 95.00 6.15 75.00 99.00 6.31 83.00 101.00 6.42 91.00 103.00 6.53 99.00 106.00 6.74 106.50 108.00 6.96 85 63.00 105.00 6.31 70.50 108.00 6.53 77.50 110.00 6.69 85.00 112.00 6.96 93.00 114.00 7.12 99.50 116.00 7.38 95 57.50 113.00 6.47 65.00 116.00 6.74 72.00 119.00 6.96 79.00 121.00 7.22 86.00 123.00 7.54 93.00 125.00 7.86 105 52.50 122.00 6.63 59.00 125.00 6.90 66.00 128.00 7.33 72.50 130.00 7.60 79.00 132.00 8.00 85.00 133.00 8.45 115 47.00 130.00 6.74 53.50 133.00 7.12 60.00 137.00 7.60 66.00 139.00 8.00 72.00 141.00 8.45 79.00 143.00 8.88 125 42.00 140.00 6.90 48.00 143.00 7.38 54.00 145.00 7.81 59.50 147.00 8.45 65.00 150.00 8.94 71.00 152.00 9.52 MODEL : CL090, HERMETIC RECIPROCATING (DUAL) COMP. 0 75 79.00 98.00 6.32 88.50 101.00 6.63 97.50 105.00 7.04 107.00 107.00 7.34 116.50 110.00 7.75 125.00 111.00 8.11 CT MODEL : CL075, HERMETIC RECIPROCATING (DUAL) COMP. 0 75 65.00 93.00 5.30 73.00 97.00 5.60 80.00 100.00 5.90 87.50 102.00 6.20 95.00 105.00 6.45 103.00 107.00 6.70 - Total Capacity (1000 Btuh) Gross kW - Total unit power input MODEL : CL075, HERMETIC SCROLL (SINGLE) COMP. SST (0F) TC SST (0F) 125 45.00 142.00 7.24 52.00 145.00 7.75 59.00 147.00 8.26 65.00 149.00 8.87 72.00 150.00 9.38 79.50 152.00 9.90 30 35 40 45 50 55 8 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 75.00 98.00 6.74 85.50 102.00 7.10 96.50 105.00 7.44 107.50 108.00 7.60 118.00 110.00 7.97 128.50 112.00 8.34 85 69.50 107.00 6.96 80.00 110.00 7.28 90.00 114.00 7.65 100.00 117.00 8.00 110.00 119.00 8.45 120.00 121.00 8.88 95 63.00 116.00 7.17 73.00 120.00 7.60 82.50 123.00 7.97 92.00 125.00 8.51 102.00 127.00 8.83 111.00 129.00 9.31 105 58.50 124.00 7.38 67.00 128.00 7.81 76.50 130.00 8.24 85.00 133.00 8.77 94.00 135.00 9.31 103.00 137.00 9.74 115 52.50 133.00 7.60 61.00 136.00 8.00 69.00 139.50 8.56 77.50 142.00 9.10 86.00 144.00 9.68 94.50 145.00 10.27 125 46.50 142.00 7.70 54.00 145.00 8.24 62.00 147.00 8.88 70.00 150.00 9.52 77.50 152.00 10.11 85.00 154.00 10.75 PERFORMANCE DATA MODEL : CL100, HERMETIC SCROLL (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW MODEL : CL100, HERMETIC RECIPROCATING (DUAL) COMP. 0 AMBIENT TEMPERATURE - F 75 86.00 100.00 7.00 96.00 103.00 7.30 106.00 106.00 7.70 116.00 109.00 8.10 127.00 111.00 8.55 137.00 113.00 8.95 85 80.00 108.00 7.15 90.00 111.00 7.55 99.00 113.00 7.90 109.00 116.00 8.30 118.50 119.00 8.80 128.50 121.00 9.30 95 73.00 117.00 7.30 82.00 120.00 7.75 91.50 123.00 8.20 100.50 125.00 8.70 110.00 127.00 9.20 119.00 129.00 9.70 105 66.00 126.00 7.50 75.00 129.00 7.95 83.50 131.00 8.50 92.00 133.00 9.00 101.50 135.00 9.55 109.50 137.00 10.10 115 59.50 134.00 7.65 67.50 137.00 8.15 75.00 140.00 8.75 83.50 142.00 9.35 91.50 144.00 9.95 99.50 146.00 10.55 SST (0F) 125 52.00 142.00 7.85 60.00 145.00 8.40 68.00 148.00 9.00 76.00 150.00 9.60 84.00 152.00 10.30 91.00 154.00 11.10 30 35 40 45 50 55 MODEL : CL120, HERMETIC SCROLL (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 98.50 113.00 9.60 110.00 117.00 10.00 121.00 120.00 10.45 132.50 123.00 11.00 144.50 125.00 11.50 155.50 127.00 12.00 95 91.00 122.00 10.00 102.00 126.00 10.60 112.50 129.00 11.10 123.00 131.00 11.60 134.00 133.00 12.20 144.50 135.00 12.80 105 83.00 131.00 10.45 93.50 134.00 11.00 103.50 137.00 11.60 113.50 140.00 12.30 124.00 142.00 12.95 134.00 144.00 13.60 115 76.00 140.00 10.90 85.00 143.00 11.55 94.50 146.00 12.25 104.00 149.00 13.00 113.00 151.00 13.75 122.00 153.00 14.40 SST (0F) 125 67.50 148.00 11.40 77.00 150.00 12.00 86.00 153.00 12.80 94.00 155.00 13.65 113.00 157.00 14.45 111.00 159.00 15.20 30 35 40 45 50 55 MODEL: CL150, HERMETIC SCROLL (SINGLE) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 115 104 10.9 128 108 11.4 141 110 11.9 154 113 12.6 167 114 13 180 115 13.3 95 107 113 11.5 119 117 12.1 130 119.5 12.8 144 121 13.2 156 122 13.7 168 124 14.3 105 100 122 12.2 110 125 12.7 122 127 13.3 132 130 14 144 131 14.7 154 132 15.2 115 90 132 12.7 100 135 13.4 110 138 14.2 120 140 14.9 125 142 15.7 140 143 16.4 85 82.00 110.00 8.42 92.00 113.00 8.75 101.50 116.00 9.20 111.00 118.00 9.57 120.00 120.00 9.96 129.00 122.00 10.40 95 76.00 118.00 8.80 85.00 120.00 9.24 94.00 123.00 9.60 103.00 125.00 10.10 112.00 127.00 10.56 121.00 129.00 11.20 105 70.00 127.00 9.00 78.00 130.00 9.52 87.00 133.00 10.10 95.00 135.00 10.56 104.00 138.00 11.22 112.00 140.00 11.83 115 64.00 137.00 9.24 72.00 140.00 9.90 80.00 143.00 10.56 88.00 145.00 11.16 96.00 147.00 11.77 104.00 149.00 12.38 125 57.00 145.00 9.70 65.00 148.00 10.30 72.00 151.00 11.00 80.00 153.00 11.66 88.00 155.00 12.27 95.00 157.00 12.93 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 104.00 106.00 9.15 116.00 109.00 9.65 127.00 112.00 10.20 139.00 115.00 10.80 150.50 117.00 11.40 163.00 120.00 12.00 85 97.50 115.00 9.70 109.00 118.00 10.20 120.00 120.00 10.80 131.50 123.00 11.40 143.50 126.00 12.10 154.00 128.00 12.70 95 91.00 123.00 10.20 102.00 126.00 10.80 112.50 129.00 11.40 124.00 132.00 12.20 135.50 134.00 12.80 146.00 136.00 13.40 105 85.00 132.00 10.80 95.00 135.00 11.40 105.50 138.00 12.00 116.50 141.00 12.90 127.50 143.00 13.60 137.50 146.00 14.40 115 78.50 141.00 11.30 88.50 144.00 11.95 98.50 147.00 12.80 108.50 150.00 13.60 119.00 153.00 14.45 128.50 155.00 15.10 125 72.50 149.00 11.60 82.00 152.00 12.70 92.00 154.00 13.40 102.00 156.00 14.30 111.00 158.00 15.20 120.50 160.00 16.05 MODEL: CL150, HERMETIC SCROLL (DUAL) COMP. 0 75 122 95 10.3 136 100 10.9 150 102 11.3 165 104 11.7 180 106 12.1 196 108 12.6 75 88.00 100.00 8.10 98.00 104.00 8.42 109.00 107.00 8.75 118.50 110.00 9.10 128.00 112.00 9.41 138.00 114.00 9.74 MODEL : CL120, HERMETIC SCROLL (DUAL) COMP. 0 75 106.00 105.00 9.20 118.50 108.00 9.50 130.00 111.00 9.95 142.50 114.00 10.35 154.50 117.00 10.80 166.50 119.00 11.25 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F SST (0F) 125 83 141 13.4 92 144 14.1 101 146 14.9 110 147 15.7 118 148 16.2 128 148.5 16.9 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 120 95 10.6 134 98 11.3 144 100 11.8 162 102 12.4 176 104 12.9 191.5 105 13.3 85 114 104 11.4 126 109 12.1 140 110 12.7 153 112 13.2 166 114 13.9 180 115 14.5 95 107.5 114 12.2 119 118 13 131 120 13.6 143 122 14.1 155 124 15 168 125 15.6 105 100 123 13 110 127 13.8 122 129 14.5 136 131 15.2 145 132 15.9 156 134 16.5 115 92.5 134 13.9 102 136 14.5 113 138 15.3 124 140 16 134 141 16.8 145 142 17.4 LEGEND: SST - Saturated Suction Temperature; TC - Total Capacity (1000 Btuh) Gross; CT - Condensing Temperature (0F); kW - Total unit power input 9 125 86 142 14.5 94 144.5 15.3 105 147 16.1 114 149 16.9 124 150 17.7 134 151 18.6 PERFORMANCE DATA MODEL : CL180, HERMETIC SCROLL (DUAL) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW MODEL : CL220, HERMETIC SCROLL (DUAL) COMP. AMBIENT TEMPERATURE - 0F 75 159 98 12.4 175 100 12.6 192 101 12.8 208 102 13 224 103 13 240 103 13.3 85 151 107 13.7 171 109 14.1 182 110 14.3 197 113 14.8 213 114 15 229 116 15.3 95 147 117 15.4 157 119 15.7 172 122 16.3 187 125 16.8 202 127 17.1 218 128 17.3 105 134 128 17.2 148 130 17.5 168 132 17.9 177 134 18.3 192 136 18.6 207 137 18.8 115 127 136 18.6 141 138 18.9 155 140 19.3 168 142 19.6 182 144 19.9 196 145 20.1 SST (0F) 125 119 145 20 131 147 20.5 145 148 20.6 159 149 20.7 173 150 20.9 187 151 21.1 30 35 40 45 50 55 MODEL : CL240, HERMETIC SCROLL (DUAL) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - F 85 221 110 20.66 243.8 112.5 21.3 266.6 116.7 22.5 289.4 118.3 23 312.2 120.3 23.4 335 121.4 24 95 206 120 23.2 228.76 122.7 23.9 251.52 125.8 24.6 274.28 128.3 25.3 297.04 130 25.9 319.8 131.5 26.4 105 194.4 130 25.6 216.06 132.7 26.3 237.72 134.2 26.8 259.38 136.5 27.2 281.04 139.5 28 302.7 140.5 28.4 115 179.2 140 27.9 200.48 141.6 28.4 221.76 145 29.3 243.04 146.25 29.7 264.32 148.1 30.3 285.6 150 30.7 75 190 100 14.5 208 103 15.2 227 107 15.8 244 110 16.6 263.2 112 17 282 113 17.4 85 179 110 16.5 197.5 114 16.8 216 116 17.8 233 120 18.6 251.5 121 18.9 268.4 123 19.5 95 170 120 18.6 187.4 123 19.2 205.6 126 19.8 222 128 20.3 239.5 130 20.8 258 131 21.2 105 160 130 20.7 176 133 21.2 192.5 135.5 21.9 208.7 138 22.5 225 140 22.9 242 141.5 23.3 115 150 140 22.8 164.1 142 23.2 182.2 144 23.6 198 145 23.9 213.5 147 24.2 229 148 25.9 SST (0F) 125 167.8 150 30 189.08 151.42 30.8 210.36 153.4 31.41 231.64 155.2 32 252.92 157.5 32.6 274.2 160 33 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 271.75 102 21.18 298.4 104 22.4 325.05 106 23.16 351.7 108 23.9 378.35 110 24.4 405 112 25.14 85 257.4 112 24.8 282.9 114 25.4 308.4 116 26.18 333.9 120 27.3 359.4 121.4 27.9 384.9 122.5 28.18 95 241.2 120 27 265.8 124 28.37 290.4 126.5 29.1 315 128.5 29.8 339.6 130 30.25 364.2 132 31 105 229.11 130 29.8 252.48 134 31.3 275.85 136.6 32.12 299.22 138.3 32.54 322.59 140 33.16 345.96 141 33.5 115 216.4 141 33 237.84 142 33.4 259.28 144 34 280.72 147 34.8 302.16 151 36.3 323.6 155 37.5 MODEL : CL360, HERMETIC SCROLL (DUAL) COMP. SST (0F) 30 35 40 45 50 55 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 75 290.2 98 26.8 321.93 100 27.25 353.66 102 27.76 385.39 104 28.2 417.12 105 28.4 448.85 106.6 28.8 85 276.5 108 29 306.98 110 29.5 337.46 111.7 29.9 367.94 113.4 30.53 398.42 114.6 30.9 428.9 116.4 31.2 95 260.1 117 31.2 288.94 119 31.8 317.79 121 32.2 346.63 122.5 32.8 375.48 124 33.2 404.32 125.7 33.6 105 245 126 33.3 272.88 128 34 300.77 130 34.4 328.65 131.6 35 356.54 133.5 35.4 384.42 135 35.8 115 230.2 136 35.64 256.12 138 36.2 282.05 140 36.8 307.97 141 37.2 333.9 142.5 37.4 359.82 144 37.9 125 139.5 147.5 23.2 153.4 149 24.7 170 151 25.1 189.5 152 25.5 200 154 25.8 216 155 26.1 MODEL : CL300, HERMETIC SCROLL (DUAL) COMP. 0 75 236.2 100 18.4 260.14 104 19.41 284.08 107 20.25 308.02 110 21 331.96 111.5 21.33 355.9 112.8 21.86 TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW TC CT kW AMBIENT TEMPERATURE - 0F 125 215 145 37.8 240 147 38.47 265 149 38.9 290 151 39.2 315 152.5 39.5 340 154 40.5 LEGEND: SST - Saturated Suction Temperature TC - Total Capacity (1000 Btuh) Gross CT - Condensing Temperature (0F) kW - Total unit power input 10 125 200.1 145 34.2 221.73 150 35.6 243.36 154 37.3 264.99 156 38.8 286.62 158 40.2 308.25 160 41.7 ELECTRICAL DATA SINGLE COMPRESSOR (HERMETIC RECIPROCATING) UNITS MODEL NUMBER POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR LEGEND: * MIN. MAX. RLA LRA FAN MOTOR FLA (each) MCA MOCP FLA - Full Load Amps LRA - Locked Rotor Amps RLA - Rated Load Amps CL030 220/240-1-50 198 264 16.9 85.8 1.9 23 35 CL030 380/415-3-50 (4 WIRE) 342 457 5.6 39 1.9 8.9 15 CL036 220/240-1-50 198 264 20.4 105 1.9 27.4 45 CL036 380/415-3-50 (4 WIRE) 342 457 8.2 50 1.9 12.2 20 MOCP - Maximum Over Current Protection CL042 380/415-3-50 (4 WIRE) 342 457 8.2 50 2.3 12.6 20 CL048 380/415-3-50 (4 WIRE) 342 457 10.4 55 2.3 15.3 25 * Single phase motors (220/240V-1Ph-50Hz), CL060 380/415-3-50 (4 WIRE) 342 457 9.6 65 2.3 14.3 20 MCA MOCP MCA - Minimum Circuit Amps up to CL150 only SINGLE COMPRESSOR (SCROLL) UNITS MODEL NUMBER POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE MIN. MAX. * COMPRESSOR FAN (each) MOTOR FLA (each) RLA LRA CL075 380/415-3-50 (4 WIRE) 342 457 12 101 2.3 19.6 30 CL090 380/415-3-50 (4 WIRE) 342 457 16.4 95 2.3 25.1 40 CL100 380/415-3-50 (4 WIRE) 342 457 17.3 111 2.3 26.2 40 CL120 380/415-3-50 (4 WIRE) 342 457 19.6 118 2.3 29.1 45 CL150 380/415-3-50 (4 WIRE) 342 457 25.6 167 2.5 37 60 MCA MOCP 20 DUAL COMPRESSOR (HERMETIC RECIPROCATING) UNITS MODEL NUMBER POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE MIN. MAX. * COMPRESSOR FAN (each) MOTOR FLA (each) RLA LRA CL075 380/415-3-50 (4 WIRE) 342 457 5.9 42 2.3 17.8 CL090 380/415-3-50 (4 WIRE) 342 457 8.2 50 2.3 23 30 CL100 380/415-3-50 (4 WIRE) 342 457 10.4 55 2.3 28 35 MCA MOCP 35 DUAL COMPRESSOR (SCROLL) UNITS MODEL NUMBER POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE MIN. MAX. * FAN COMPRESSOR (each) MOTOR FLA (each) RLA LRA CL120 380/415-3-50 (4 WIRE) 342 457 10 74 2.3 27.1 CL150 380/415-3-50 (4 WIRE) 342 457 12 101 2.5 32 40 CL180 380/415-3-50 (4 WIRE) 342 457 17.3 111 1.9 42.7 60 CL220 380/415-3-50 (4 WIRE) 342 457 19.2 125 1.9 47 60 CL240 380/415-3-50 (4 WIRE) 342 457 19.6 118 2.9 49.9 60 CL300 380/415-3-50 (4 WIRE) 342 457 25.6 167 2.9 63.4 80 CL360 380/415-3-50 (4 WIRE) 342 457 27.2 198 2.9 69.9 90 NOTE: If other than 900C copper wire is used, size can be determined from unit ampacity given in above table and applicable table of NEC. Wire size selected must have current capacity not less than that of copper wire specified and voltage drop should not exceed 2% of rated voltage. Must use copper wire from disconnect switch to the unit. 11 DIMENSIONS CL030 - CL060 NOTES: 1. All dimensions are in mm, (dimensions in brackets are in inches). 2. Allow 32" (812mm) clearance to service end of the unit, 12" (305mm) on remaining sides and 24" (610mm) between units for proper airflow. MODEL NUMBER A B C D E F G H CL030 - CL036 711 610 708 596 440 175 86 57 CL042 - CL060 889 813 806 695 538 216 99 72 12 DIMENSIONS CL075 - CL120 NOTES: 1. All dimensions are in mm, (dimensions in brackets are in inches). 2. Allow 32" (812 mm) clearance to service end of the unit, 24" (610 mm) on remaining sides and 48" (1219 mm) between units for proper airflow. 13 DIMENSIONS CL150 - CL220 NOTES: 1. All dimensions are in mm, (dimensions in brackets are in inches). 2. Allow 32" (812 mm) clearance to service end of the unit, 48" (1219 mm) on remaining sides for proper airflow. 14 DIMENSIONS CL240 - CL300 NOTES: 1. All dimensions are in mm, (dimensions in brackets are in inches). 2. Allow 48" (1219 mm) clearance on all sides for proper airflow. 15 DIMENSIONS 203 [8.0"] 1550 [61.0"] CL360 2121 [83.50"] 73 [2.88"] 2197 [86.50"] 943 [37.13"] 943 [37.13"] 2032 [80.0"] NOTES: 1. All dimensions are in mm, (dimensions in brackets are in inches). 2. Allow 48" (1219 mm) clearance on all sides for proper airflow. 16 TYPICAL SCHEMATIC WIRING DIAGRAM (Single compressor units - Cool only) LEGEND AHU AI AR ATB CAP CC CB C. HTR COMP FM FMC FR HPS HVTB JP L1 L2 L3 LPS LUG N AIR HANDLING UNIT ANTI ICE THERMOSTAT AUXILIARY RELAY AUXILIARY TERMINAL BLOCK CAPACITOR COMPRESSOR CONTACTOR CIRCUIT BREAKER CRANKCASE HEATER COMPRESSOR FAN MOTOR (CONDENSER) FAN MOTOR CONTACTOR FAULT RELAY HIGH PRESSURE SWITCH HIGH VOLTAGE TERMINAL BLOCK JUMPER LINE 1 LINE 2 LINE 3 LOW PRESSURE SWITCH LUG GROUND NEUTRAL NTB RR SD TRANS T'STAT UVM VFC NEUTRAL TERMINAL BLOCK RESET RELAY SMOKE DETECTOR TRANSFORMER THERMOSTAT UNDER VOLTAGE MONITOR VOLT FREE CONTACT FIELD WIRING DISCONNECT TAB - 1/4" SPLICE-CLOSED END ___ + CONTROL & INTERCONN. DETAILS FOR FML AHU W/O SYSTEMIZER NOTES 1. POWER SUPPLY, REFER TO UNIT NAMEPLATE. 2. ANY WIRE REPLACEMENT SHOULD BE OF THE 900C OR ITS EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY. NOTE: ATB# 1,4 & 5 OF COND. UNIT TO BE CONNECTED TO ATB# 1,4 & 5 OF A.H.U ACCORDINGLY. 3. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP. IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE HEATER MUST BE ON FOR 12 HOURS BEFORE OPERATING THE SYSTEM. OPTIONS 1. UVM OPTION L1 L2 L3 L1 L2 L3 A. UNIT ON & OFF INDICATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN COMPRESSOR DAMAGE. 4. HPS OPTION 3. VOLT FREE CONTACT OPTIONS B. COMP ON/OFF & TRIP & [UNIT] TRIP INDICATION OPTION FOR BQ & FML UNITS UVM 4. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY END USER WITH RATING AS RECOMMENDED BY COOLINE. 5. TO ATB TO ATB * ATB 3 IS APPLICABLE FOR PDS OPTION UNITS ONLY. 6. REMOVE JUMPER FOR AI OPTION. ROUTE AI WIRES FROM AHU. (REMOVE JP1) 2. SMOKE DETECTOR OPTION NOTE: Refer to unit control box (inside panel) for exact wiring diagram. 17 TYPICAL SCHEMATIC WIRING DIAGRAM (Dual compressor units - Cool only) LEGEND CONNECTION APPLICABLE FOR 1PH FAN MOTOR ONLY LOW AMBIENT OPTION WITH 2 SPEED FM LOW AMBIENT OPTION WITH 1 SPEED FM CRANKCASE HTR CONNECTION AHU AI AR ATB CAP CC CB C. HTR COMP FM FMC FR HPS HVTB JP L1 L2 L3 LPS LUG N AIR HANDLING UNIT ANTI ICE THERMOSTAT AUXILIARY RELAY AUXILIARY TERMINAL BLOCK CAPACITOR COMPRESSOR CONTACTOR CIRCUIT BREAKER CRANKCASE HEATER COMPRESSOR FAN MOTOR (CONDENSER) FAN MOTOR CONTACTOR FAULT RELAY HIGH PRESSURE SWITCH HIGH VOLTAGE TERMINAL BLOCK JUMPER LINE 1 LINE 2 LINE 3 LOW PRESSURE SWITCH LUG GROUND NEUTRAL NTB RR SD TRANS T'STAT UVM VFC NEUTRAL TERMINAL BLOCK RESET RELAY SMOKE DETECTOR TRANSFORMER THERMOSTAT UNDER VOLTAGE MONITOR VOLT FREE CONTACT FIELD WIRING DISCONNECT TAB - 1/4" SPLICE-CLOSED END ___ + NOTES 1. POWER SUPPLY, REFER TO UNIT NAMEPLATE. OPTIONS 1. UVM OPTION L1 L2 3. VOLT FREE CONTACT OPTIONS L3 A. UNIT ON & OFF INDICATION 4. HPS OPTION B. COMP ON, OFF & TRIP [&] UNIT TRIP INDICATION OPTION 2. ANY WIRE REPLACEMENT SHOULD BE OF THE 900C OR ITS EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY. 3. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP. IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE HEATER MUST BE ON FOR 12 HOURS BEFORE OPERATING THE SYSTEM. UVM TO ATB FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN COMPRESSOR DAMAGE. TO ATB (REMOVE JP1) 4. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY END USER WITH RATING AS RECOMMENDED BY COOLINE. 2. SMOKE DETECTOR OPTION 5. * ATB 3 & 5 IS APPLICABLE FOR PDS OPTION UNITS ONLY. 6. USE DISCONNECT TAB OR SPLICE ONLY WHERE EVER REQUIRED FOR EXTENSION OF ORIGINAL WIRE. 7. REMOVE JUMPER FOR AI OPTION. ROUTE AI WIRES FROM AHU. NOTE: Refer to unit control box (inside panel) for exact wiring diagram. 18 TYPICAL SCHEMATIC WIRING DIAGRAM (Heat pump units) LEGEND NTB N LUG HVTB L1 L2 L3 CC JP5 37A N 36B 37B T1A T2A T3A 36A 37A CAP2 35B CAP1 35A COMP FM2 FM1 N L1 ATB1 TRANS CB 16 15 1 1 24 VAC [UVM] 1A JP1 [SD] 1B 17 JP2 JP11 LOW AMBIENT OPTION TO CC T1A TO CC TO JP5 T2A 37B TO JP5 37A 17 21 8 41A CAP2 37B JP4 22 R-V 9 CAP1 JP3 20 "7"CONN. NOT REQ'D FOR CS/FL/FML (FCU)-AHU 36B 7 17 CC 35B 20 37A LPS 22A 6 FCS SEE NOTE-5 [AI] 26A 25A JP12 36A SEE HPS OPTION BELOW 35A 5 TO BQ & FML UNITS 24V CIRCUIT FM1 FM2 CRANKCASE HTR CONNECTION L1 COMP C.HTR L2 NAME OPEN (PSIG) CLOSE (PSIG) NOTE: ATB# 1,6,8,9,T3A & 37A OF COND. UNIT LPS 25 ± 5 50 ± 5 TO BE CONNECTED TO ATB# 1,6,8,9,T3A & 37A HPS 450 ± 10 360 ± 15 OF A.H.U ACCORDINGLY. PLS REMOVE JP5 FCS 190 ± 15 290 ± 10 OPTIONS 3. VOLT FREE CONTACT OPTIONS FOR BQ & FML UNITS L2 L3 ATB1 15 ATB2 17 AR1 ATB1 9 41A ATB2 17 FR-2 FR FR-2 UVM 45 AR1-1 46 AR1-1 47 43 44 FR-1 TO ATB 1 55 TO ATB 1A UNIT ON (REMOVE JP1) UNIT OFF UNIT/COMP-TRIP 54 CCA-2A L1 4. HPS OPTION B. COMP ON, OFF & TRIP [&] UNIT TRIP INDICATION OPTION FOR BQ & FML UNITS CCA-2B A. UNIT ON & OFF INDICATION 56 57 COMP-ON COMP-OFF COMP-TRIP 2.SMOKE DETECTOR OPTION L1 1A 1B ATB2 ATB2 + HPS 25A 1. POWER SUPPLY, REFER TO UNIT NAMEPLATE. 2. ANY WIRE REPLACEMENT SHOULD BE OF THE 900C OR ITS EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY. 3. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP. IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE HEATER MUST BE ON FOR 12 HOURS BEFORE OPERATING THE SYSTEM. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN COMPRESSOR DAMAGE. 4. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY END USER WITH RATING AS RECOMMENDED BY COOLINE. 5. REMOVE JUMPER FOR AI OPTION. ROUTE AI WIRES FROM AHU. 6. USE DISCONNECT TAB OR SPLICE ONLY WHERE EVER REQUIRED FOR EXTENSION OF ORIGINAL WIRE. ATB2 DCT-2 ATB2 N REMOVE JP4 DCT-1 REMOVE JP2 58 23A NEUTRAL TERMINAL BLOCK RESET RELAY SMOKE DETECTOR TRANSFORMER THERMOSTAT UNDER VOLTAGE MONITOR VOLT FREE CONTACT FIELD WIRING DISCONNECT TAB - 1/4" SPLICE-CLOSED END DEFROST CONTROL OPTION FOR BQ UNIT ONLY DCT VFC-FROM CUSTOMER'S SMOKE DETECTOR TO LPS NTB RR SD TRANS T'STAT UVM VFC NOTES SET POINTS 1. UVM OPTION AIR HANDLING UNIT ANTI ICE THERMOSTAT AUXILIARY RELAY AUXILIARY TERMINAL BLOCK CAPACITOR COMPRESSOR CONTACTOR CIRCUIT BREAKER CRANKCASE HEATER COMPRESSOR FAN MOTOR (CONDENSER) FAN MOTOR CONTACTOR FAULT RELAY HIGH PRESSURE SWITCH HIGH VOLTAGE TERMINAL BLOCK JUMPER LINE 1 LINE 2 LINE 3 LOW PRESSURE SWITCH LUG GROUND NEUTRAL ___ USE FOR OPTION-3B ONLY CONTROL & INTERCONN. DETAILS FOR FML AHU W/O SYSTEMIZER AHU AI AR ATB CAP CC CB C. HTR COMP FM FMC FR HPS HVTB JP L1 L2 L3 LPS LUG N ATB2 DCT-3 ATB2 37A N REMOVE JP5 REMOVE JP3 NOTE: Refer to unit control box (inside panel) for exact wiring diagram. 19 INSTALLATION & START-UP INSTRUCTIONS SAFETY CONSIDERATIONS Improper installation, service, maintenance or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Check with your nearest COOLINE dealer/sales office for information or assistance. For detailed instructions/informations, please refer to corresponding IOM manual. Warning: Before installation or servicing the system, always turn off main power supply. Electrical shock can cause personal injury or death. INSTALLATION STEP-1: Check equipment and job site Unpack unit and move to final location taking care not to damage the unit. Remove screws holding the unit to wooden pallet and after removing wooden pallet, refix the screws. STEP- 2: Installation on a solid, level mounting pad For proper drainage, the condensing unit must be raised off the mounting pad. If conditions require the unit be attached to the pad, tie down bolts should be used. When installing, allow sufficient space for airflow clearance, wiring, refrigerant piping and service. Double the service access when multiple units are installed at one location. On rooftop applications, locate unit at least 6" (152 mm) above roof surface. Place unit above a load-bearing wall, isolate unit and piping set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. STEP-3: Piping connections Outdoor units should be connected to indoor units using field-supplied piping of refrigerant grade and correct size. The liquid and suction line diameters can be determined from the physical data table. For piping requirements beyond 25 ft (7.62m), obtain information from your nearest COOLINE dealer/sales office. If either refrigerant piping or indoor coil is exposed to atmospheric conditions, it must be dehydrated to 500 microns to eliminate moisture contamination in the system. It is advisable to size piping according to recommended ASHRAE methods. Install piping according to refrigeration standard practice. Run refrigerant pipes as directly as possible, avoiding unnecessary turns and bends. Install refrigerant pipes carefully to prevent damaging the suction pipe insulation and vibration transmission to the structure. Outdoor unit connected to factory matched indoor unit Outdoor unit contains correct system refrigerant charge for operation with matched indoor unit as given on cooling capacity table and when connected with up to 25 ft (7.62 m) of field-supplied piping. Check refrigerant charge for maximum efficiency. Sweat connection Use refrigerant grade piping. Service valves are closed from factory when shipped and ready for brazing. After wrapping the service valve with a wet cloth, the piping set can be brazed to service valve using either silver rod or silfos rod brazing material. When brazing completed, refrigerant piping and indoor coil are now ready for leak testing. This check should also include all field and factory brazed joints. 20 ELECTRICAL STEP 1: INSTALLATION A) Please ensure power supply to the unit is as per unit nameplate (Volts/Ph/Hz) requirements. Caution: Operation of the unit on improper power supply will result in damage to the unit. Note: Use copper wires of proper rating for all field wiring. Warning: Before servicing or installation of the unit, always TURN OFF all power to the unit. There may be more than one disconnect switch. Ensure all of them are turned off. Electrical shock can cause personal injury or death. B) Ground & power wires Connect power wires to terminal block per wiring diagram. Connect ground wire to the ground lug inside the control box. C) Control wiring between outdoor & indoor unit Use 16 gauge color-coded wire between the indoor and outdoor units (control wiring). STEP 2: START-UP 1) Energize crankcase heater for a minimum of 12 hours prior to the system start-up. To energize crankcase heater only, set thermostat to "off" position and close electrical disconnect switch to the outdoor unit. 2) Fully open liquid/suction service valves. 3) Close electrical disconnect switch to energize the system. 4) Set room thermostat to desired temperature. SYSTEM DESIGN THE COOLINE CONDENSING UNIT SYSTEM HAS BEEN DESIGNED BASED ON THE FOLLOWING: • Intended for outdoor installation with free air intake and discharge. • Minimum outdoor operating air temperature during cooling without low ambient operation option is 55 F. • Maximum outdoor operating air temperature during cooling is 130 F. • For reliable operation, unit should be level on horizontal plane. • Maximum elevation of indoor unit above or below the outdoor unit is: indoor unit above = 50 feet, indoor unit below =150 feet. • For interconnecting refrigerant pipe lengths greater than 25 feet, check with your local COOLINE sales office. • Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of 0 0 connector provided. 21 PARTS LIST (Single compressor units) MODEL NUMBER COMPRESSOR CL030B CL030L CL036B CL036L CL042L CL048L CL060L 800-674-94 800-684-14 800-684-13 800-684-09 800-684-09 800-672-52 800-643-01 FAN MOTOR 800-545-72 800-545-72 800-545-72 800-545-72 800-555-26 800-555-26 800-555-26 FAN MOTOR CAPACITOR 800-572-83 800-353-15 800-576-04 800-353-15 800-353-15 800-353-15 800-353-15 CONDENSER FAN 800-224-26 800-224-26 800-224-26 800-224-26 800-225-02 800-225-02 800-225-02 COMPRESSOR CONTACTOR 800-097-00 800-095-00 800-097-00 800-095-00 800-095-00 800-095-00 800-095-00 TRANSFORMER (24V) 800-012-30 800-012-30 800-012-30 800-012-30 800-012-30 800-012-30 800-012-30 LOW PRESSURE SWITCH 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 MODEL NUMBER COMPRESSOR CL075L CL090L CL100L CL120L CL150L 800-674-78 800-674-81 800-674-67 800-674-19 800-674-12 FAN MOTOR 800-555-26 800-555-26 800-555-26 800-555-26 800-545-67 FAN MOTOR CAPACITOR 800-353-15 800-353-15 800-353-15 800-353-15 800-572-20 CONDENSER FAN 800-225-02 800-225-02 800-225-02 800-225-02 800-224-23 COMPRESSOR CONTACTOR 800-095-00 800-095-00 800-095-00 800-097-00 800-736-22 TRANSFORMER (24V) 800-012-00 800-012-00 800-012-00 800-012-00 800-012-14 LOW PRESSURE SWITCH 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 HIGH PRESSURE SWITCH (OPTIONAL) 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 Dual compressor units MODEL NUMBER COMPRESSOR, Hermetic COMPRESSOR, Scroll CL075L CL090L CL100L CL120L CL150L CL180L CL220L 800-684-08 800-684-09 800-672-52 N.A. N.A. N.A. N.A. CL240L N.A. N.A. N.A. N.A. 800-674-25 800-674-78 800-674-67 800-674-38 800-674-19 800-555-06 FAN MOTOR 800-555-26 800-555-26 800-555-26 800-555-26 800-545-67 800-545-68 800-545-68 FAN MOTOR CAPACITOR 800-353-15 800-353-15 800-353-15 800-353-15 800-572-20 N.A. N.A. N.A. CONDENSER FAN 800-225-02 800-225-02 800-225-02 800-225-02 800-224-23 800-224-23 800-224-23 800-224-28 COMP. CONTACTOR, Hermetic 800-095-00 800-095-00 800-095-00 800-095-00 800-095-00 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 800-095-01 800-736-22 800-098-61 TRANSFORMER (24V) 800-012-14 800-012-14 800-012-14 800-012-14 800-012-14 800-012-14 800-012-14 800-012-30 LOW PRESSURE SWITCH 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 HIGH PRESSURE SWITCH (OPTIONAL) 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 COMP. CONTACTOR, Scroll MODEL NUMBER CL300L CL360L COMPRESSOR, Scroll 800-674-72 800-674-72 COMP. CONTACTOR, Scroll 800-098-61 800-098-61 FAN MOTOR 800-555-06 800-555-06 FAN MOTOR CONTACTOR 800-098-51 800-098-51 CONDENSER FAN 800-224-28 800-224-28 TRANSFORMER (24V) 800-012-30 800-012-30 LOW PRESSURE SWITCH 800-557-00 800-557-00 HIGH PRESSURE SWITCH (OPTIONAL) 800-558-00 800-558-00 22