DOCUMENT NO.: PM-PXP40HF-0504 REVISION NO.: 4 OPERATION & SERVICE MANUAL MODEL: PXP-40HF (PORTABLE X-RAY UNIT) Product Manual: PXP-40HF Ltd. Poskom Co., CONTENTS PART I. OPERATION MANUAL 1 General description ---------------------------------------------------------------------- 3 2 Operational safety ---------------------------------------------------------------------- 5 3 Working environment ---------------------------------------------------------------------- 6 4 Radiation safety ---------------------------------------------------------------------- 6 5 System configuration ---------------------------------------------------------------------- 7 6 Function of x-ray unit ---------------------------------------------------------------------- 7 7 Specifications --------------------------------------------------------------------- 8 8 Display of each parts --------------------------------------------------------------------- 9 9 Operation of the machine ---------------------------------------------------------------------- 10 10 Operation mode ---------------------------------------------------------------------- 11 11 Remote control function ---------------------------------------------------------------------- 12 12 Technical chart for small animal ---------------------------------------------------------------------- 19 13 Equine chart ---------------------------------------------------------------------- 20 ---------------------------------------------------------------------- 8 TABLES 1 Specifications ILLUSTRATIONS 1 Operation device & display ---------------------------------------------------------------------- 9 2 Dimensions ---------------------------------------------------------------------- 16 3 Labels ---------------------------------------------------------------------- 17 PART II. SERVICE MANUAL 1 Notice ---------------------------------------------------------------------- 21 2 Operation sheet ---------------------------------------------------------------------- 21 3 Block diagram ---------------------------------------------------------------------- 22 4 Operation board and layout ---------------------------------------------------------------------- 23 5 Power board layout ---------------------------------------------------------------------- 24 6 Calibration process ---------------------------------------------------------------------- 25 7 Calibration code and data ---------------------------------------------------------------------- 29 8 Error code and countermeasures ---------------------------------------------------------------------- 30 9 Schematics ---------------------------------------------------------------------- 31 TABLES 1 mA calibration code and data ---------------------------------------------------------------------- 29 2 Filament calibration data ---------------------------------------------------------------------- 29 3 Error code and measures ---------------------------------------------------------------------- 30 2 Product Manual: PXP-40HF Ltd. Poskom Co., PART I. OPERATION 1. GENERAL DESCRIPTION 1.1. OVERVIEW PXP-40HF is one of PXP-HF portable family generators. Likewise of others, the PXP-40HF is most compact, ultra-light weight and powerful HF inverter type of x-ray systems in this portable category. It is designed especially for nursing home care or home care medical market and small medical clinics as well as veterinary practitioner or battle field use. All PXP-HF family x-ray units are the ripple free HF type of generator in producing 40~50% more powerful radiation output than conventional x-ray units in its class. Therefore, PXP-40HF is the perfect x-ray portable unit for an indoor and outdoor medical diagnostic practitioner in the radiographic application where requires an easy of operation and mobility. Features are; -Ultra light weight and compact size -High frequency type of generator -High output 100kV / 35mA -APR pre-set (8) memory PROM -Remote control software -Built in collimator and laser pointer (option) -Auto line compensation -Digital readout reverse switch -Accessories: metal carrying case, hand switch, power cord -Power requirement: 110/220 Volt, 50 / 60 Hz 1.2. CONSOLIDATED MANUAL This consolidated manual consists of operating and service instruction. This operator’s manual provides PXP-40HF operating instructions for X-ray technicians, radiologists and other medical personal trained in the use of X-ray equipment. Service manual provides installation instruction, calibration and routine maintenance for field service personnel. This manual is not designed to replace or substitute for certified training in the radiological or medical field. In reading this manual, the operator should be qualified in the use of equipment of this type. This portable X-ray system is only to be used by licensed practitioners in diagnostic, operative and postoperative procedures. PXP-40HF portable X-ray can be used in variety of diagnostic radiographic systems such as mobile stand or radiographic table integrated with X-ray tube mounting devices. Although many of the features of these portable systems were developed with radiographic application in mind, operation is described in general terms to permit the use of those features in radiographic application 3 Product Manual: PXP-40HF Ltd. Poskom Co., 1.3. SAFTY REQUIREMENT This manual provides guideline for the safe use and operation of the portable system. The operator should be in trained in the use of equipment of this type and should refer to this manual in conjunction with that training. It is the responsibility of the owner to ensure that the system is operated only by properly trained, qualified personnel who have obtained credentials from local, state, and federal authorities where required. Potential hazards exist in the use of medical electronic devices and x-ray systems. All users and operators must understand the safety and emergency procedures, and the operating instructions given in this manual Poskom Co., Ltd. certifies that each system complies with the Radiation Control for Health Safety Act in Title 21, Chapter I, subchapter J of the Code of Federal Regulation in the USA and EN 60601, general requirements for radiation protection in diagnostic X-Ray equipment for IEC 601-1-3 in European Nations. Poskom and distributors assume no responsibility or liability for after-sale operating and safety practices, nor can it be responsible for personal injury or damage resulting form misuse of its portable x-ray systems. Please address a question and comments regarding safety issue to Poskom service organization and/or each distributor in your region. 1.4. CAUTIONS AND WARNING Possible hazards are associated with unsafe operation of this type of portable X-ray equipment. These hazards are described on the following warning or caution signs with the safety precautions which should be taken. CAUTION The X-ray radiation could be dangerous for patients and operators unless following safety regulations are strictly observed. 4 Product Manual: PXP-40HF Ltd. 2. Poskom Co., OPERATIONAL SAFETY PXP-40HF users’ safety, easy of operation and product reliability are our major concern in designing this PXP-HF family of generators. However, it is advisable to observe the following instruction and guideline for your additional safety in operating this portable. A. This product should be operated only by or under the supervision of legally qualified persons. B. PXP-40HF is designed for the radiographic uses and not for fluoroscopy or other associated applications. C. PXP-40HF should be used for the diagnosis, not for the therapy. D. PXP-40HF is specified as ClassⅠtype B equipment under the IEC 601-1,2 standard. THE PORTABLE IS NOT PROTECTED AGAINST INGRESSING A WATER OR LIQUIDS. E. Do not modify the equipment at your discretion and in case any modification is required unavoidably, ask the help of Poskom or its authorized dealer for the service. F. This system has been calibrated for optimal operations. G. If you have any troubles with the equipment, turn off power immediately, and notify to Poskom or its authorized dealer for their service and assistance. H. If you want to connect any devices made by other companies to this equipment, ask Poskom or its authorized dealers for their instructions. 5 Product Manual: PXP-40HF Ltd. Poskom Co., 3. WORKING ENVIRONMENT 3.1 Avoid following places for the normal operation and safe storage. A. Where the equipment is exposed to water vapor. B. Where the equipment is exposed to direct sunlight. C. Where the equipment is exposed to dust. D. Where the equipment is exposed to high humidity. E. Where there is a ventilation problem. F. Where the equipment is exposed to salty atmosphere. G. Where the equipment is exposed to chemicals or gas. 3.2. For sound operation of the machine, it should keep away from the place with strong vibration and maintain proper environment and conditions. A. Operation Environment Temperature range 10°C ~ 40°C, Relative Humidity Range 30% ~ 75% RH B. Optimal Temperature and Humidity Temperature range 17°C ~ 23°C, Relative Humidity Range 40% ~ 60% RH 3.3. For safe storage and transportation, you must keep following range of temperature, humidity and atmosphere. Environment for storage and transportation Temperature range -25°C ~ +60°C Relative Humidity Range 10% ~ 95% RH 4. RADIATION SAFETY CAUTION The ionized radiation could be dangerous for patients and operators unless following safety regulations are strictly observed. A. Users and operators should wear appropriate protecting devices and clothes. B. Stay distance from the radiant sources and all the possible secondary radiation zones. C. Eliminate all unnecessary objects near the exposure zones. D. The distance from the focus to skin should be kept at least 20 cm. E. For the experimental uses, please apply the lowest possible values about kV, mAs and exposure time. F. Be careful not to exceed the limited radiograms in the exposure area. 6 Product Manual: PXP-40HF Ltd. Poskom Co., 5. SYSTEM CONFIGURATION 5.1. PXP-40HF is a radiological device for medical uses. It should be applied for the radiographic diagnosis and operated by qualified practitioners. Users have to comply with safety and health regulations concerning the ionizing protection and the electrical and mechanical safety of the medical devices. 5.2. PXP-40HF is composed of the following parts and devices: They should be firmly fixed and connected with each other for the sound and normal operation. A. Operation Board B. Inverter C. HV Tank including X-ray Tube D. Collimator E. Exposure Switch F. Power Cord 5.3. Supplied outfit and documents A. Aluminum Carrying Case B. Operation Manual C. Service Manual D. Power Plug E. Hand Switch (When you push hand switch in order to make radiography, it should be pressed by two steps: step one is ready and step two is the exposure.) 6. FUNCTION OF X-RAY UNIT 6.1. PXP-40HF is designed and manufactured to gain the best radiographic results and long service life of the x-ray tube. 6.2. kV and mAs setting method A. Select the kV and mAs values using kV, mAs up/down switch. B. APR (Anatomical Programming Radiography): Users can select kV and mAs values and save them. (8 memory) 6.3. Parameter selection by the operator (kV/mA). A. kV: The operator can adjust the kV value; the system automatically sets the maximum value of mA producing the best radiographic results. B. mAs: The operator can adjust the mAs value; the system automatically sets the minimum value of kV producing the best radiographic result. 7 Product Manual: PXP-40HF Ltd. Poskom Co., 7. SPECIFICATIONS [Table 1. Specifications] Output Power Input Power 2.4 kW Voltage 100V-120V, 200V-240V Phase & Frequency Single / 50/60 Hz Current Short time 30A /15A Radiography kV Range in 1kV steps Tube voltage current mAs 40kV ~ 50kV 35mA 0.4 ~ 100 51kV ~ 70kV 30mA 0.4 ~ 64 61kV ~ 70kV 25mA 80 ~ 100 71kV ~ 80kV 30mA 0.4 ~ 32 71kV ~ 80kV 25mA 40 ~80 81kV ~ 90kV 25mA 0.4 ~ 40 81kV ~ 90kV 20mA 50 ~ 80 91kV ~ 100kV 20mA 0.4 ~ 50 91kV ~ 100kV 16mA 64 ~ 80 MAs Range 0.4mAs – 100mAs, 25steps Max. kV Deviation ±7 % Max. mAs Deviation ±10 % Indication kV (error code) /mAs: 7-segment LED X-ray Tube Model Name D-124 TOSHIBA Focal Spot 1.2 mmx1.2 mm Target Angle 16 degree Anode Heat Storage 20 kHU Heat Dissipation 250 HU/sec Total Filtration 2.5 mm Al eq. @ 100kV Tube: 0.8mmAl, Colli.: 0.5mmAl, Add Al Filt.: 1.2mmAl Compensation for the Supply Power Automatic Regulations Collimator with Type Double slit type, Manual operation Laser Pointer Min. x-ray field size ≦5cm x 5cm @1m SID Max. x-ray field size 35cm x 35cm @ 65cm SID Laser Pointer Class : ⅢA Timer Push button illuminator with 30 sec timer Lamp 12V 50W Halogen Dimension Weight 5mW See drawing Fig- (460mmx250mmx200mm) 12.8 kg (26.4 lb.) 8 Product Manual: PXP-40HF Ltd. Poskom Co., 8. DISPLAY OF EACH PARTS Illustraion1. Operation devices and display 3 5 4 13 6 10 8 12 11 1 2 9 No. Description 7 Function 1 kV indicator Display kV value (range: 40 -100kV) 2 mAs indicator Display mAs value (range: 0.4-100mAs) 3 Ready lamp Lighted when you push the hand switch one time for preparation 4 Exposure lamp Alert lamp during x-ray exposure 5 Wait lamp Lighted until the second exposure started 6 kV up/down switch Select kV value by up or down buttons 7 mAs up/down switch Select mAs value by up or down buttons 8 APR Switch (1-8) Memory setting is available for 8 APR data 9 Store APR Data Save the selected APR Data 10 Display reversal switch Help to read LED value of kV, mAs reversed 11 Collimator lamp on Switch for operation of the lamp inside the collimator 12 Laser pointer To adjust exposure focus 13 Error lamp Lighted in case of system problem 9 Product Manual: PXP-40HF Ltd. Poskom Co., 9. OPERATION OF THE MACHINE 9.1. OPERATION PRACTICES A. Wear a lead apron while you make exposures. B. Stay distance at least 2 m from the unit or extend the cord of hand switch as long as possible in order to secure enough space for your safety. C. Use proper field size and technical values for each procedure to minimize x-ray exposure dose and gain the best radiographic result. D. Be careful about the decimal point on the mAs display in order to acquire intended mAs values. E. When you make exposure to the patient on the bed, ask visitors to leave the room first and keep appropriate distance from the patient. F. Pay attention to the maintenance schedule of the device and keep up with it. G. Cumulative radiation dose usually does not exceed recommended maximum levels. However, if you make radiographic exposures using high kV and mAs quite often, the evaluation of the specialist is needed to check whether extra protective devices are necessary for the user or not. WARNING Please check weather the voltage and frequency of the power supply are in accordance with the figures written in the system labels, which attached on the body of the machine. The levels of voltage should move within ±10% of the nominal values. CAUTION The operation of the machine should not be started unless all verifications and connections are fully prepared. 9.2. POSITIONING OF PATIENT A. Place the loaded cassette on the patient’s backside. B. Arrange the SID (Focal Spot to Image Receptor Distance) using a scale located on the side of the collimator. C. Turn on the collimator lamp and laser pointer by pushing collimator/laser on switch. D. Adjust the size of the x-ray beam in accordance with the film size using the x-ray field adjustment knobs. Turn off the collimator and laser pointer after 30 seconds on the timer. CAUTION For the first installation of the machine or operation after long period of non-use, it needs to be preheated to secure long service life of the tube. Following method of pilot test will relieve the damage on the x-ray tube. Operate the machine with low kV values (50kV 5mAs) three times in row and execute with higher values [70kV 5mAs] three times in row again. Then high kV values [90kV 5mAs] will be applied without big troubles or pressures on the machine. 10 Product Manual: PXP-40HF Ltd. Poskom Co., 10. OPERATION MODE 10.1. NORMAL MODE A. Please open the carrying case. B. Connect power plug into the PXP-40HF device. C. Turn on the line switch and the display will be shown up as follows. kV mAs D. Select the kV values using the [6] kV up/down switch. E. Select the mAs values using the [7] mAs up/down switch. F. Positioning the machine at the ready condition by one time pushing of the hand switch. G. When the [3] ready LED lighted, press the hand switch again and make exposure. During the xray exposure, x-ray LED will be lighted on. H. After the exposure is ended, [5] “wait LED” sign will be lighted on and off for the waiting time. 10.2. APR MODE A. Please open the carrying case. B. Connect power plug into the PXP-40HF device. C. Turn on the line switch and the display will be shown up as follows. kV mAs D. Select the [8] APR switch out of 1~8. E. Select the kV values using the [6] kV up/down switch. F. Select the mAs values using the [7] mAs up/down switch. G. Save the selected kV and mAs figures with pushing the [9] “store” button. H. When the [3] ready LED sign appears, press the hand switch again and make exposure. During the x-ray exposure, the [4] X-ray LED will be lighted on. I. After the exposure is ended, [5] “wait LED” will be lighted on and off for the waiting time. NOTE As it was illustrated in the front pages, the exposure switch should be pressed by two steps. However, you can make immediate exposure in case the filament of the tube is hot enough. CAUTION If you want to make exposures several times in row, wait until the [5] wait lamp is lighted off. If the number of consecutive exposure exceeds three times (at higher than 50mAs), wait for 3 minutes in order to prevent overheating of the machine. 11 Product Manual: PXP-40HF Ltd. Poskom Co., 11. REMOTE CONTROL FUCTION & OPERATION 11.1. INTRODUCTION Currently, mAs, kVp and Pre-set memory techniques (Prom memory) can be selected by the operator by depressing push buttons or by scrolling displays on a control panel. Each technique or mode selection depends on an anatomic region or view for radiographic examination. The collimator lamp and laser pointer is turned “on” by the lamp push-button and turned “off” by a 30 second collimator timer run off. Many portable operators and field users have suggested we find a better way to select an exposure technique and parameters along with mAs, kVp and pre-set Prom memory values. Most field operators hold portable X-Ray units with one hand, while holding the exposure hand switch with the other hand. This makes selecting technique factors on the control panel awkward without dropping the portable unit or hand switch. We have modified our X-ray portable software and functions of the Prep. and Exposure hand switch to allow selection of all exposure parameters (mAs & kVp) and control of the collimator lamp and laser beam. The exposure hand switch consists of a two step hand switch. The first (1) stage of the hand switch is called the “Preparation (Prep. or Ready)” stage. The second (2) stage of the hand switch is called the “Exposure (Exp or X-Ray out)“ stage. (See drawing 1.) All functions of the remote control described above are executed by clicking the first stage on the hand switch which is the “Prep.” mode of operation. Each remote control function and technique value selection is described below. (Drawing 1) 1st stage switch = Prep. Switch 2nd stage switch = Exp. Switch Hand switch housing 11.2. REMOTE CONTROL MODE 12 Product Manual: PXP-40HF Ltd. Poskom Co., The kVp and mAs setting, memory selection and collimator lamp and laser pointer illumination functions are controlled remotely by the hand switch by pressing the “Prep.” stage push-button as follows: ATTENTION Click the “Prep.” hand switch three (3) times consecutively. This will allow you to enter in the “remote hand control” menu mode for operation. <TRIPLE CLICK> 11.3. MEMORY SELELCTION When you click the PREP stage hand switch quickly three (3) times, the Pre-set Memory station LED (PXP-20HF: 1-4 / PXP-40HF & 60HF: 1-8) will blink sequentially as well as the kVp and mAs LED readouts. Make a single (1) click with the hand switch when the desired pre-set memory station lamp begins to blink. This will cause the pre-set memory data to be selected and displayed in the control LCD window. NOTE All pre-set memory data should be entered and stored at each memory station (PXP-20HF: 1-4 / PXP-60HF: 1-8), prior to performing the above mode of operation. 11.4. kVp SELELCTION One (1) click of the “Prep” switch will cause the kVp LED readout to blink. You will now be in the kVp selection menu mode. The kVp values increase by one (1) kVp unit per click of the “Prep.” switch. If you depress and hold the prep switch for a few second, the kVp readout will increases rapidly up to the maximum value (PXP-20HF: 90kVp / PXP-40HF & 60HF: 100kVp). The kVp readout will circulate from lowest to highest values as long as you hold and press the button. When the desired kV readout appears on the control display panel, release the prep hand switch and wait for a few seconds. The kVp value will set up automatically. 13 Product Manual: PXP-40HF Ltd. 11.5. Poskom Co., mAs SELECTION mAs selection is similar to the kVp selection mode. Click the “Prep” hand switch once to make the mAs LED readout blink. You will be in the mAs selection menu mode. The mAs value will increase with each click of the “Prep” switch (0.4mAs to the maximum mAs of each portable x-ray unit). If you wish to increase the mAs value quickly, simply hold the “Prep” switch down one stage. (PX-20HF: 50mAs / PXP-40HF & 60HF: 100mAs). The mAs readout will circulate as long as you hold the “Prep” switch. When the desired mAs readout appears on the control display panel, release the prep hand switch and wait for a few seconds. Then mAs value will set automatically. 11.6. COLLIMATOR / LASER BEAM TURNED ON ATTENTION Click the Prep. hand switch rapidly twice. The collimator lamp and laser pointer beam will illuminate for X-ray exposure positioning. <DOUBLE CLICK> With the exposure technique (mAs & kVp) set with your remote hand switch, you are ready to make a radiographic exposure for examination. It is very important to position the right region of interest on a patient’s anatomy. Therefore, the collimator beam must be turned on to confirm the size of region and size of film covered. The laser beam must also be turned on for checking the precise center of the target prior to making a final X-ray exposure. When the Prep switch is rapidly clicked twice, the collimator lamp and laser beam will turn on simultaneously until the lamp timer (30 seconds) runs off. However, it will turn off automatically when x-ray exposure sequence is completed. 11.7. X-RAY EXPOSURE WARNING When an X-ray exposure is made in a room or outdoors, lower radiation will scatter throughout the surrounding area. An authorized operator is expected to take precautions and is highly recommended to ware a lead apron and gloves if necessary for your patient’s and your own protection. After the x-ray exposure technique is selected and collimator light beam size is adjusted with the collimator blade knob, an x-ray exposure can be made by an authorized individual of the medical clinic or hospital. X-RAY EXPOSURE SEQUENCE: A. Press the Prep hand switch (1st stage) and hold B. Press down the 2nd stage hand switch. Exposure will be made automatically by the exposure timer. 14 Product Manual: PXP-40HF Ltd. < 1ST STAGE> Poskom Co., <2ND STAGE> 11.8. REMOTE CONTROL OVERRIDE NOTE TO THE USER All of the before mentioned remote control hand switch functions and operations can also be accomplished via the one-touch control panel. All exposure functions and parameters can be Overridden through the main control panel prior to final exposure. (See user’s manual for directions on how to use the main control panel) 15 Product Manual: PXP-40HF Ltd. Poskom Co., Illustration 2. Dimension (Main Unit & Carrying Case) 1) PXP-40HF 2) CARRYING CASE (ALUMINUM) 16 Product Manual: PXP-40HF Ltd. Poskom Co., Illustration 3. Labels PXP-40HF Portable label sticker and location Warning: This X-ray unit maybe dangerous to patient and operator unless safe exposure factors and operation instruction are observed DIAGNOSTIC X-RAY UNIT MODEL: PXP-40HF SER. NO.: DATE: Input Rating: AC220~240V, 50/60 Hz Rating: X-ray Tube Voltage: 40~100kV X-ray current: 20~35mA Operation condition: Time interval between 3 exposure: 3 min (When the mAs is higher than 50) Filtration: Total filtration: Min 2.5 mmAl Tube: 0.8 mmAl, collimator, 0.5 mmAl, Al Filt.: 1.2mmAl X-ray tube (TOSHIBA), Model: D-124, Serial no.: Focal spot: 1.2mm X 1.2mm POSKOM Room 405, Unitech Ville Bldg., 1141-2, Baeksuk-dong, Ilsan-gu, Goyang, Korea Take adequate Precautions to prevent the possibility of any persons carelessly exposing themselves or others to radiation. High Voltage Tank MODEL: HV-40 SER.NO: XXXXXX Rating: Max. 100kV, 35mA, Max output: 2.4 kVA POSKOM Room 405, Unitech Ville Bldg., 1141-2, Baeksuk-dong, Ilsan-gu, Goyang, Korea Warning: Electric shock hazard do not remove cover Reserve Servicing to qualified personnel. Beam Limiting Device (Collimator) MODEL: PCMAX-100 SER.NO: XXXXXXX Input Rating: 12V, 50W Min. X-ray field size: Below 5cm x 5 cm at SID 100cm Max. X-ray field size: Below 35cm x 35cm at SID 65cm Max. Tube Voltage: 100kV, Inherent filtration: 0.5 mmAl POSKOM Room 405, Unitech Ville Bldg., 1141-2, Baeksuk-dong, Ilsan-gu, Goyang, Korea 17 Product Manual: PXP-40HF Ltd. Poskom Co., DANGER LASER LIGHT BEAM DO NOT STARE INTO BEAM Wavelength: 650 nm Output Power: 5mW Laser Class: III A Product This device complies with 21 CFR CH.I Sub J Regulation Veterinary Use only 18 Product Manual: PXP-40HF Ltd. Poskom Co., 12. TECHNIQUE CHART FOR SMALL ANIMALS 100 cm (40 Inch) SID, GRID: 103 lines / 6:1 ratio Film/Screen: Fuji RX-U/ Rare earth [Table 2. Chart for small animals] Thickness (cm) Skull / Pelvis/ Extrim kVp /(mAs) Thorax kVp / (mAs) Abdomen kVp / (mAs) 2-3 No grid : 50 / (0.4) 4-5 No grid : 54 / (0.4) 6-7 No grid : 54 /(0.5) No grid: 66 / (0.4) No grid : 60 / (0.6) 8-9 No grid : 60 /( 0.6) No grid: 70 / (0.4) No grid : 60 / (0.8) 10-11 66 / (1.6) No grid: 74 / (0.4) No grid : 60 / ( 1.0) 12-13 70 / (1.6) 78 / (0.8) 64 / (2.0) 14-15 72 / (1.6) 80 / (0.8) 68 / (2.5) 16-17 72 / (2.0) 86 / (0.8) 68 / (2.5) 18-19 74 / (2.4) 90 / (0.8) 70 / (3.2) 20-21 76 / (2.4) 90 / (1.2) 74 / (3.2) 22-23 80 / (2.4) 96 / (1.2) 80 / (4.0) NOTE The contents in the table are recommended for starting radiographic techniques. The final radiography of proper image density and resolution depends on many factors. Please follow the next adjustment and common rules if necessary. 1. Add or subtract 2 kVp for 1 cm increase or decrease in thickness of body section. 2. If films are too dark, decrease mAs value on the next lower station. 3. If films are too light, increase mAs value on the next higher station 19 Product Manual: PXP-40HF Ltd. Poskom Co., 13. EQUINE CHART 66 cm (26 Inch) Distance 400 Speed Rare Earth Film / Screen [Table 3. Equine Chart] ANATOMY VIEW High Contrast Mid-Contrast kV mAs kV mAs AP 66 1.2 72 0.8 LAT 66 1.0 72 0.6 P3 62 0.8 - - AP 66 1.2 72 0.8 LAT 66 1.0 72 0.6 AP/FLEX 66 1.2 72 0.8 LAT/OBI 66 1.0 72 0.6 SPLINT BONE LAT 58 0.8 68 0.6 HOCK AP/HIGH 66 1.6 72 1.0 AP/LOW 66 1.2 72 0.8 LAT 66 1.0 72 0.6 LAT - - 78 2.0 PA - - 78 4.0 AP - - 78 2.0 OTHER - - 78 1.2 NAVICULAR FETLOCK KNEE STIFLE ELBOW ALTERNATIVE TECHNIQUES STIFLE LAT 45 cm distance 78 1.2 PA 45 cm distance 78 2.5 AP 65 cm distance 68 2.5 LAT 65 cm distance 68 2.0 FOAL 85 cm distance 90 0.8 300LBS 85 cm distance 100 1.2 500LBS 85 cm distance 100 4.0 SINUS LAT 85 cm distance 88 1.2 SHOULDER LAT 75 cm distance 86 3.2 OBI 75 cm distance 86 4.0 NAVICULAR CHEST 20 Product Manual: PXP-40HF Ltd. Poskom Co., PART II. SERVICE 1. NOTICE 1.1. If the output calibration is needed after periodical inspections or repairs, please observe following rules and methods. CAUTION The ionized radiation is dangerous for the operator if the following safety measures are not strictly observed. 1.2. This manual is designed to ensure correct use and operation of PXP-40HF. Please read all the lines thoroughly before you use this equipment. 1.3. Incorrect use and operation exceeding described conditions in this manual may occur damage of the machine and shorten its life. Particular attention must be paid to all the warnings, cautions and notes incorporated herein. 1.4. This equipment should be used only by the legally qualified persons and practitioners. 1.5. Regarding the AC cable and software, only the one developed and supplied by Poskom should be used. 1.6. No responsibility is taken by Poskom for any infringement of patients or other rights of the third parties which many results from the use of this manual. 1.7. Always keep the manual at hand for your reference. 2. OPERATION SHEET APR SWITCH 1~8 kV UP/DOWN SWITCH 21 Product Manual: PXP-40HF Ltd. Poskom Co., LASER SWITCH COLLIMATOR ON/OFF SWITCH STORE SWITCH mAs UP/DOWN SWITCH 22 Product Manual: PXP-40HF Ltd. Poskom Co., 3. BLOCK DIAGRAM READY HTP24-CTL-001 1 2 X-RAY CON1 3 35312-03 HAND SWITCH 3V/35mA LASER POINTER CONTROL BOARD OP PANEL 1 2 CON6 1 2 CON2 * EXPORT : NORMAL 35312-02 * DOMESTIC : NOT USED LASER & HT CONT. TANK T 2 35312-02 35312-05 CON3 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 THERMAL EP_FB(-) 35312-05 35312-11 CON2 /100V_SEL LAMP_CONT FIL_FB EP_CONT2 FIL_CONT1 FIL_CONT2 IP_FB(+) EP(-) GND IP(+) 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 +5V DGND +12V AGND -12V EP_CONT1 AGND 1 CON4 35312-11 1 2 3 4 5 CON5 35312-05 CON3 HT XFMR T1 TB1 T1 20 1 2 3 575 T2 TB2 CON5 COM D-124S 35312-03 HTP24-PWR-001 FG PWR & DRIVE T2 CON4 FILAMENT DRIVE CB1 1 2 3 4 C1 3 2 +12.2 SHIELD GND SHIELD LINE C2 53258-04 3 FIL XFMR 250V/16A 5 4 3 2 1 250V/20A 53258-05 CON1 COLLIMATOR DRIVECON6 1 2 COLLIMATOR CN1 PLUG AC MALE LAMP SHIELD LINE 53258-02 12V/100W APPROVED BY DESIGNED BY <OrgName> HTP-24 Main Block CHECKED BY DATE Size A3 FSCM NO. DWG NO Rev 00 <Cage Code> Sheet 1 23 of 1 Product Manual: PXP-40HF Ltd. Poskom Co., 4. OPERATION BOARD AND LAYOUT 24 Product Manual: PXP-40HF Ltd. Poskom Co., 5. POWER BOARD LAYOUT 25 Product Manual: PXP-40HF Ltd. Poskom Co., -PREPARATION Following tools and instruments are needed. a. Tools: Philips screwdriver No.1 & 2, Straight slot screwdriver b. Instruments: DVM, oscilloscope (Tektro TDS 3032 and more than Equivalent) 6. CALIBRATION PROCESS 6.1. Line Power Supply -Line switch should be at off position. -Connect power line cord to the power outlet. -Turn on the line switch. -Then the LED on the operation panel illuminates. 6.2. Calibration procedures are composed of three steps. -Tube voltage confirmation and calibration. -Tube current confirmation and calibration. -Filament preheat calibration A. Calibration and Confirmation of Tube Voltage -Turn off the line switch. -Lift up the control panel from the unit, and then the PCB OP board appears. -All DIP switches on the PCB OP board are turned off. (Note: DIP switch is usually located in this location.) -Connect the channel one probe of the oscilloscope to TP5 (IP F/B). -Connect the channel another one probe of the oscilloscope to TP6 (EP F/B). Channel 1 is mA, and 35mA = 7V Channel 2 is kV, and 40kV = 2V -Connect the ground to TP11 (GND). -Turn on the line switch and the display indicates as follows. kV mAs -Set the kV and the mAs at 40kV and 0.4mAs (60mA). Then observe the mA waveform of the oscilloscope channel 1. -If it is not about 9V, adjust mA by VR3 on the OP board. Then observe the kV waveform of the oscilloscope channel 2. -If it is not 2V, adjust kV by VR2 on the OP board. After adjustment, set the tube voltage kV to 80KV by the kV up/down switch. -Set the kV and the mAs at 80kV and 0.4mAs(30mA).Then observe the mAs, kV waveform of the oscilloscope channel 1, 2. 26 Product Manual: PXP-40HF Ltd. Poskom Co., -If it is not about 6V, adjust mA by VR3 on the OP board. -If it is not about 4V, adjust kV by VR2 on the OP board. B. Calibration and Confirmation of Tube Current -Turn off the line switch. -Lift up the control panel from the unit, and then the PCB OP board appears. -All DIP switches on the PCB OP board are turned off. (Note: DIP switch is usually in this position.) -Connect the channel one probe of the oscilloscope to TP5 (IP F/B). -Connect the channel another one probe of the oscilloscope to TP6 (EP F/B). Channel 1 is mA, and 35 mA = 7V Channel 2 is kV, and 40 kV = 2V -Connect the ground to TP11 (GND). -Turn on the line switch and the display indicates as follows. mAs kV -Set the kV and the mAs at 40kV and 0.4mAs (35mA). Then observe the mA waveform of the oscilloscope channel 1. -If it is not 7V, adjust mA by the calibration data on the OP board. -Turn off the line switch, and wait until the display switch the light off. -DIP switch 1 on the PCB OP board is turned on. -Turn on the line switch and the display indicates as follows. -Then push the mAs up switch (see operation sheet). The display indicates as follows. kV Calibration code mAs Calibration data C00 is calibration code of tube current (35mA at 40kV~60kV). 179 is calibration data of tube current (35mA at 40kV~60kV). -Adjust mA by the mAs up/down switch (see operation sheet). -After it is adjusted, push the store switch (see operation sheet). -DIP switch 1 on the PCB OP board is turned off then exposure X-ray. -If it is not 7V, set the calibration data again. -DIP switch 1 on the PCB OP board is turned on. -Then push the kV up switch (see operation sheet). 27 Product Manual: PXP-40HF Ltd. Poskom Co., The display indicates as follows. mAs kV Calibration code Calibration data C01 is calibration code of tube current (40mA at 61kV~70kV). 153 is calibration data of tube current (40mA at 61kV~70kV). -Adjust mA by the mAs up/down switch (see operation sheet). -After it is adjusted, push the store switch (see operation sheet). -DIP switch 1 on the PCB OP board is turned off then exposure X-ray. -If it is not 6V, set the calibration data again. -Table .1 shows the calibration code and the calibration data against an each tube current. C. Filament preheat calibration -This is preheating filament for making tube current. -The overshoot or the undershoot may occur from the tube current if the preheat calibration data or the VR3(preheat gain volume) is set by mistake. -There are two methods to make preheat calibration setting. The calibration data is possible to be changed in accordance with the tube condition. -The VR3(preheat gain volume) adjusts the whole range of tube current. Filament preheat calibration data adjusts each tube current. -Turn off the line switch. -Lift up the control panel from the unit, and then the PCB OP Board appears. -DIP switch 1 on the PCB OP board is turned on. -Turn on the line switch. -Push APR switch ① and then the display indicates as follows. mAs kV Preheat calibration code Preheat calibration data P00 is Filament preheat calibration code (Preheat calibration code of 60mA). 17 is Filament preheat calibration data (Preheat calibration data of 60mA). -Adjust data by the mAs up/down switch (see operation sheet). -After it is adjusted, push the store switch (see operation sheet). -DIP switch 1 on the PCB OP board is turned off then exposure X-ray. If overshoot or undershoot occur in the waveform, set the calibration data again. Then push the kV up switch (see operation sheet). The display indicates as follows. 28 Product Manual: PXP-40HF Ltd. kV Preheat calibration code Poskom Co., mAs Preheat calibration data P01 is Filament preheat calibration code (Preheat calibration code of 40mA). 37 is Filament preheat calibration data (Preheat calibration data of 40mA). -Adjust data by the mAs up/down switch ⑥ (on the control panel). -After it is adjusted, push the Store switch ⑨ (on the control panel). -DIP switch 1 on the PCB OP board is turned off then exposure X-ray. -If overshoot or undershoot occur in the waveform, set the calibration data again. -Table. 2 shows the calibration code and the calibration data against an each tube current. The calibration data is possible to be changed in accordance with the tube condition. 29 Product Manual: PXP-40HF Ltd. Poskom Co., 7. CALIBRATION CODE AND DATA [Table 1. mA Calibration Data] AC voltage Code Data Tube voltage Tube current mAs 220V 220V 220V 220V 220V 220V 220V 220V 220V 110V 110V 110V 110V 110V 110V 110V 110V 110V C00 C01 C02 C03 C04 C05 C06 C07 C08 C09 C10 C11 C12 C13 C14 C15 C16 C17 179 153 128 153 128 128 102 102 82 179 179 153 133 133 102 102 102 82 40kV ~ 60kV 61kV ~ 70kV 61kV ~ 70kV 71kV ~ 80kV 71kV ~ 80kV 81kV ~ 90kV 81kV ~ 90kV 91kV ~ 100kV 91kV ~ 100kV 40kV ~ 60kV 61kV ~ 70kV 61kV ~ 70kV 71kV ~ 80kV 71kV ~ 80kV 81kV ~ 90kV 81kV ~ 90kV 91kV ~ 100kV 91kV ~ 100kV 35mA 30mA 25mA 30mA 25mA 25mA 20mA 20mA 16mA 35mA 30mA 25mA 30mA 25mA 25mA 20mA 20mA 16mA 0.4 ~ 100 0.4 ~ 64 80 ~ 100 0.4 ~ 32 40 ~80 0.4 ~ 40 50 ~ 80 0.4 ~ 50 64 ~ 80 0.4 ~ 100 0.4 ~ 64 80 ~ 100 0.4 ~ 32 40 ~80 0.4 ~ 40 50 ~ 80 0.4 ~ 50 64 ~ 80 [Table 2. Filament Preheat Calibration Code and Data] AC voltage Code Data Tube current 220V 220V 220V 220V 220V 110V 110V 110V 110V 110V P00 P01 P02 P03 P04 P05 P06 P07 P08 P09 17 25 45 70 84 15 38 50 73 89 35mA 30mA 25mA 20mA 16mA 35mA 30mA 25mA 20mA 16mA 30 Product Manual: PXP-40HF Ltd. Poskom Co., 8. ERROR CODE & COUNTERMEASURE [Table 3. Code & Measures] Error Code Err. 07 Err. 08 Err. 10 Err. 11 Err. 12 Err. 14 Err. 15 Err. 16 Err. 17 Err. 19 Err. 21 Content Action When the line switch is turned on, this is inspected. The ready contactor of the hand switch is closed even it is not pushed. When the line switch is turned on, this is inspected. The x-ray contactor of the hand switch is closed even it is not pushed. It is displayed when the FIL FB signal is not detected in the state of standby. It is displayed when the EP FB signal is not detected in the state of standby. It is displayed when the IP FB signal is not detected in the state of standby. It is displayed when the FIL FB signal is not detected in the state of ready. It is displayed when the EP FB signal is low in the state of exposure. It is displayed when the IP FB signal is low in the state of exposure. It is displayed when the IP FB and EP FB signal is high in the state of exposure. It is displayed when the mAs is over in the state of exposure. It is displayed when the connector CON6 on the main board is not insert. 31 Change the hand switch Change the hand switch Replace operation board or Replace HV tank Replace operation board or Replace HV tank Replace operation board or Replace HV tank Replace main board or Replace power board Replace operation board Replace main board or Replace power board Replace main board or replace power board Check the IP FB level and adjust it Replace operation board Check CON3 9. SCHEMATICS TD62304 +5V SEG08_OUT1 (1M-6) LED4 WAIT 2 1 RED LED5 M1 2 LED10 M6 2 LED11 M7 2 LED12 M8 2 LED13 ERROR 2 1 RED 1 GREEN 1 GREEN LED6 M2 2 uD_SR105K 1 GREEN LED7 M3 2 5 9 1 2 4 6 10 DP G F E D C 7 CC CC SEG5 3 8 SEG4 B A 10 9 1 2 4 5 DP G F E D 7 6 C B CC CC A 10 9 1 2 4 6 7 5 DP G F E D C B CC CC uD_SR105K LED3 X-RAY 2 1 YELLOW 1 GREEN A 5 10 9 1 2 4 6 SEG3 3 8 uD_SR105K LED2 READY 2 1 GREEN 1 GREEN DP G F E D C 7 CC CC SEG2 3 8 uD_SR105K 3 8 SEG1 B A 10 9 1 2 4 6 7 5 DP G F E D C B 5 CC CC A A 10 2 9 R28 15 1/4W 1 G 2 1 R27 15 1/4W 1 F 2 2 R26 15 1/4W 1 E 2 4 2 R25 15 1/4W 1 D 2 R24 15 1/4W 1 3 8 Q1 Q2 Q3 Q4 Q5 Q6 Q7 VCC 6 2 R23 15 1/4W 1 DP I1 I2 I3 I4 I5 I6 I7 GND 16 15 14 13 12 11 10 9 3 8 SEG01_OUT SEG02_OUT SEG03_OUT SEG04_OUT SEG05_OUT SEG06_OUT SEG07_OUT 1 2 3 4 5 6 7 8 CC CC U8 (1B-13) (1B-13) (1B-12) (1B-12) (1B-12) (1B-12) (1B-12) C 2 R22 15 1/4W 1 7 R21 15 1/4W 1 (2F-5) (2G-5) (2H-5) (2J-5) (2K-5) (2L-5) (2N-5) (2O-5) B SEG_A SEG_B SEG_C SEG_D SEG_E SEG_F SEG_G SEG_DP uD_SR105K LED8 M4 2 1 GREEN 1 GREEN SEG6 uD_SR105K LED9 M5 2 1 GREEN LED14 REVERSE 2 1 GREEN APPROVED BY DESIGNED BY HTP-24 PORTABLE X-RAY CONTROL BOARD OP PANEL & HT CONT. CHECKED BY DATE Size A3 FSCM NO. <Cage Code> DWG NO Rev 0 HTP24-CTL-001 Sheet 3 of 7 Product Manual: PXP-40HF Ltd. Poskom Co., 1 +5V RA7 2 3 4 5 4.7K CON6 ISO_PWR (1B-10),(7G-13) (1B-10),(5N-13) 2 3 /FAULT IP_FB_IN R29 270 ISO_GND 2 1 35312-0310 2 1 D33 1N4148 PC1 8 2 7 3 6 4 5 (1B-10) HS_READY 1 1 CON1 1 2 3 4 (1B-9) 2 1 35312-0410 2 R30 270 D34 1N4148 HS_X-RAY 1 TLP620-2 +5V D36 D35 CON2 1 1 2 2 1N4148 2 1 1N4148 (1M-7) /LASER 35312-0210 APPROVED BY DESIGNED BY HTP-24 PORTABLE X-RAY CONTROL BOARD OP PANEL & HT CONT. CHECKED BY DATE Size A3 FSCM NO. <Cage Code> DWG NO Rev HTP24-CTL-001 0 Sheet 4 33 of 7 Product Manual: PXP-40HF Ltd. Poskom Co., (7B-13) IP_FB R31 10K 1% (1J-5) IP_FB_ADC R32 +12V 2 10K 1% 1 R33 1 14 1 39K 3 12 4 C62 1N4148 1 -12V 1SC CPI COM +VS -VS FOUT VOUT 5 10 11 BOX332 2 7 13 (1B-10),(4J-11) IP_FB_IN VFC32 MN104 1 1 C22 +IN -IN +12V VR1 10K 2 8 2 D38 + R35 1/2W 200 C21 1 U10 2 1 2 3 + 2 R34 4.7k LM358 - 1N4148 40mA(0 ~ 8V) U9A 4 D37 C24 1 6.8uF/16V tantal BOX103 2 CON3 1 IP_FB(+) 2 3 EP_FB(+) C60 2 39P 1 4 R75 5 100K 1% 35312-0510 (1A-10) (6B-14),(7B-11) /HT_CHECK +12V 2 8 D39 1N4148 100KV(0 ~ -5V) 1 1N4148 C58 2 R76 1K 1K (1J-5) EP_FB_ADC R84 R U9B MN104 1 1 1 2 BOX223 BOX223 1 1 R36 7 4 D40 BOX223 LM358 2 C27 + 6 2 2 2 2 C26 5 100K 1% 1 R37 C25 EP_FB +12V C28 MN104 1 2 -12V C63 VR2 MN104 2 1 -12V 2K 1 R38 10K 1% 3 1 C29 2 C30 2 TP3 MN104 2 MN101 1 TP4 EP_REF 1 +12V C31 1 2 MN101 1 EP_REF IP_CONT U11A LM358 MN104 2 R42 10M 6 U11B C33 MN101 + 7 (6C-5) IP_REF LM358 R44 10K 1% 2 2 2 -12V 8 1 C59 1 1 - 5 2 2 1 R43 10K 1% R40 10K 1% 1 (1F-7) 4 BOX224 (6B-14) 1 1 1 2 2 + 1 1 C32 R41 10M IP_REF 8 3 2 4 R39 10K 1% 1 (1F-7) 2 EP_CONT APPROVED BY DESIGNED BY HTP-24 PORTABLE X-RAY CONTROL BOARD OP PANEL & HT CONT. CHECKED BY DATE Size A3 FSCM NO. <Cage Code> DWG NO Rev 0 HTP24-CTL-001 Sheet 5 34 of 7 Product Manual: PXP-40HF Ltd. Poskom Co., +12V +12V R45 5.6K U12 1 (5J-9),(7B-11) (5F-4) 1 2 1 1 EP_FB EP_REF 2 R46 5.6K 1 2 2 1 2 1 2 C36 3 C34 BOX682 2 BOX102 C1 E1 12 R47 1 910 R50 1 910 CON4 2 1 2 EP_CONT1 8 9 2 3 4 EP_CONT2 1 C37 BOX102 2 R51 6.2K 1% 2 1 VCC -IN1 F.B. R49 680 R48 470K +IN1 5 CT 6 C2 E2 11 10 FIL_CONT1 FIL_CONT2 RT 4 5 6 DT 7 15 16 GND -IN2 +IN2 VR OC 7 8 LAMP_CONT 14 13 FIL_FB 9 10 C38 /100V_SEL R52 47K + 11 1uF/25V TANTAL 2 1 35312-1110 2 U13A 14066 1 1 TL494 (6B-7) 1 2 2 13 R53 2K (1M-6) /HV_ON VR3 2K R54 750 1 R56 10K 1% R55 15K 2 1 3 1 1 2 (1J-5) FIL_FB_ADC 2 2 2 +5V R57 10K 1% 1 -12V 1 2 3 C39 R62 BOX473 470K 1 1 R63 10K +12V 1 2 2 2 R82 10K 2 3 U17 1PN2222 1 1 C42 BOX102 2 R64 5K 1% R81 1 3.3K 1 2 1 R79 5.6K 1 5 6 4 7 15 16 2 R70 470K 2 2 -IN1 VCC C1 E1 8 9 10 R58 1K F.B. 12 1 2 R61 5.6K 1K +IN1 2 C41 MN104 1 2 2 CT C2 E2 11 10 RT DT GND -IN2 +IN2 1 1 1 2 12 1 2 1 R80 2 PN2222 DRV1 1 2 R65 1K VR OC 14 13 2 C40 BOX104 7 1 3 2 2 R66 1K /LAMP_ON (1M-6) 1 TL494 R78 30K (5L-4) IP_REF 1 IP_FB C61 BOX104 2 1 1 R77 5.6K U13C 14066 R67 47K 1 3 2 4 C43 BOX473 2 (6K-11) 1 11 U15 1 + R68 2K APPROVED BY 2 5 FIL_FB U13B 14066 +12V R59 5.6K OP07 6 2 4 8 U14 - 2 R60 4.7K /PREP DESIGNED BY HTP-24 PORTABLE X-RAY (1M-6) CONTROL BOARD OP PANEL & HT CONT. CHECKED BY DATE Size A3 FSCM NO. <Cage Code> DWG NO Rev 0 HTP24-CTL-001 Sheet 6 35 of 7 Product Manual: PXP-40HF Ltd. Poskom Co., +12V +12V TP5 2 +12V C44 1 R85 100k MN104 U16A 1 8 64K 3 (5I-15) 1 2 2 R86 100k + 1 LM393 1 R71 100K 4 IP_FB 2 IP_FB 1 R69 2 C45 BOX473 TP6 (1B-10),(4J-11) /FAULT TD62304AP 14066 1 1 C49 MN104 C50 MN104 2 C51 MN104 2 C48 MN104 2 2 TD62304AP 1 27512 C47 MN104 2 74HC573 4 1 LM393 100K 1 1 - C46 BOX103 R74 + C23 R73 + C35 10u/16V 56K 10u/16V +5V 1 6 2 7 2 1 (5J-9),(6B-14) R72 100K 2 2 EP_FB U16B + 1 5 8 1 EP_FB TP7 +5V 1 +5V H8 H7 H6 H5 H4 H3 H2 H1 H11 H10 H9 H12 1 1 TP8 HOLE 1 1 1 1 1 1 1 1 1 HOLE HOLE HOLE 2 2 HOLE HOLE HOLE HOLE HOLE HOLE HOLE HOLE 1 DGND 1 C53 100uF/50V 1 + 1 C52 MN104 TP9 CON5 1 2 3 4 5 1 +12V TP11 1 1 TP10 AGND 1 2 1 AGND 1 2 C55 MN104 1 C54 + 100uF/50V TP12 C57 MN104 2 C56 + 100uF/50V -12V 1 2 35312-0510 +12V APPROVED BY -12V DESIGNED BY HTP-24 PORTABLE X-RAY CONTROL BOARD OP PANEL & HT CONT. CHECKED BY DATE Size A3 FSCM NO. <Cage Code> DWG NO Rev HTP24-CTL-001 0 Sheet 7 36 of 7 Poskom Co., C9 1500/200V + C10 1500/200V 102/AC250V C17 + R12 NTC10D22 C15 1500/200V BD1 D25XB60 + C16 1500/200V R9 G2 K2 D4 D10LC40U F1 R13 10K 3 L1 1 1 TB1 R5 2W 10 G3A K3A C14 102/1KV R10 2W 10 2 Q8 68K 1W BTA26-600 Q11 3 3 3 Q7 FQL40N5 2 C4 102/1KV G4 K4 Q9 FQL40N5 2 D5 D10LC40U 1 HV TRANS NP TB2 1 2 R11 2W 10 +5V H : 220V L : 110V CN2 1 2 C18 K3 G3 SIG1(+) 100_SEL 100/400V T1 + R14 1W100 R15 2W24K C47 R16 2W 100K K2 G2 C21 222/1KV TP1 +5V 0.5A 5 6 LM7805CT IN 1 + C24 C46 MN104 C23 100/16V 100/16V + Q12 IXIF 16N90Q 1 TC7662A1 PG_S C28 TT22/16V + 3 R18 220 5 3 4 BOX104 C29 C30 BOX102 BOX472 R20 20K Z5 R19 3.9K R22 120 C31 C32 BOX103 BOX102 1N4747 R21 5W 0.2 TP6 HS2 D9 D10LC20U 1 D10 8 7 6 5 1N4937 47/25V 100V_SEL +12.2V C35 + + C34 2200/16V R23 1W680 2200/16V 1 + 5 6 S1 S1A 1 2 1 2 3 4 3 4 K4A G4A 5 6 K1A G1A R27 20 Q15 IRF540 +12.2V D12 1 2 3 4 R28 R25 5.1K Q18 PN2222 Q16 C1815 Q17 PN2907 R30 NO HEAT SINK Z6 1N4937 1W1K 20K + C40 22/25V R32 20 1N4746 CON4 53258-4 Q19 IRF540 R33 Z7 Q20 PN2907 C41 M472/100V D13 1W1K R34 20K R31 1%9.3K R35 3W 0.5/¹«À¯µµ 2 4 3 4 1N4746 +12.2V 100 PC817 3 2 2 C39 10uF/25V 3 4 5 6 M472/100V C37 Q14 PN2222 R24 1/2W470 1 GND R26 1 2 5 6 K1 G1 R41 47K 1 U5 1 2 +12.2V 12 + S4A K2A G2A +5V 6 OUT S4 SIG2(+) TP7 +12.2V 6A +12V 1 + C33 2200/16V(13pie) K4 G4 35312-11 5 U4 78L05 TP5 -12V 20mA 10 + C36 C38 100uF/25V 1 2 3 4 C25 C26 100/16V TT22/16V + U3 PG IN 3 4 5 6 1 2 3 4 5 CON2 35312-5 CON3 1 2 3 4 5 FIL_CONT 6 7 LAMP_CONT 8 9 FIL_FB 10 11 8 1 6 TP4 1 2 7 R17 4.7 8 3 MN104 +5V GND +12.2V GND -12V + + UC3844 1 TG 3 HS1 2 D11 1N4937 C45 HS3 C22 470/25V NP GND OUT 2 R29 27K 3 4 5 6 1 1 1 U2 S2L60 7 3 C2235 1 2 SIG2(-) D7 1N4937 GND TP2 1 2 K3A G3A TP3 +5V D8 C27 3 4 S2A D6 1N4937 C20 47/25V 2 4 U7 3 4 S2 R40 10K PQ32/30 1 C19 M104/100V C48 22/25V 1 2 5 6 100V SELECTION D14 1N4937 Q21 1 2 SIG1(-) L3 SQE20 1/400V S3A S3 FQL40N5 Q10 G4A K4A G2A K2A 10TURNS FET GATE DRIVE CIRCUIT FQL40N5 50T2A C6 PP105/400V C11 102/1KV 3 - C12 G1A K1A + SNUBER 1 C13 + 3 C8 102/AC250V L2 1/2W470K R8 R6 2W 10 3 R7 2 Q6 FQL40N5 D3 D10LC40U 2 1 68K 1W Q5 FQL40N5 PP105/400V C5 G3 102/1KV C7 K3 1 G1 K1 SNUBER 1 5 4 3 2 1 224/AC250V SC-10-D050 Q4 FQL40N5 D2 D10LC40U 2 1 224/AC250V Q3 FQL40N5 2 3 53258-05 CON1 CN1 100V/SW 1 2 1 Product Manual: PXP-40HF Ltd. 1N4937 1 TH 3 C42 101/3KV R37 4.7K 1 R36 5D11 C43 MN104 R38 10K ISO_GND DESIGNED BY HTP24 PWR & DRV 222/AC250V COLIMETER 2 1 3 2 1 APPROVED BY R39 1%2.4K C44 HAND SW PWR 50N60 2 ISO_5V HS4 Q13 t 2 U6 TL431 CON5 CON6 35312-3 53258-2 CHECKED BY DATE Size A3 FSCM NO. DWG NO Rev 00 HTP24-PWR-001 <Cage Code> Sheet 1 37 of 1