SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss VESSEL DESIGN DATA AND WEIGHT CALCULATION CODE ASME SEC. VIII, DIV. 1 LATEST P DESIGN PRESSURE T DESIGN TEMPERATURE 250 E WELD JOINT EFFCIENCY 0.85 CA CORROSION ALLOWANCE 6.0 / F.V Barg Deg. C 1.5 mm MATERIAL OF CONSTRUCTION SHELL SA 515 GR. 70 SKIRT IS : 2062 GR. A CONSTRUCTION DETAILS D SHELL ID H Overall Column Height h SKIRT HEIGHT 1.5 Met 30.4 Met 5 Met OTHER INFORMATION Liquid Hold up : 1500 mm from Bottom T.L. Type of dished end : 2 : 1, Ellipsoidal Insulation : Yes (HOT) 100 mm. Internals : 30 Trays (Valve Type) Complete column is divided into 6 section as shown in the sketch below Sr. No II III IV V VI 1 Mean Diameter LEVELS units mm I 1536 1512 1512 1510 1510 1508 Total 2 Height mm 5000 5000 5000 5000 5000 5390 3 Shell/Dish Kg 2750 2240 2240 1860 1860 1655 4 Body Flange Kg 0 0 0 0 0 0 5 Nozzles Kg 100 160 160 160 160 160 6 Trays /Packing Kg 0 400 700 600 700 600 7 Liquid Hold up Kg 0 3530 910 780 910 780 8 Water Total Kg 0 9200 8830 8830 8830 9200 9 Insulation/Attachme Kg 500 300 300 300 300 300 10 Erection Weight Kg 2850 2400 2400 2020 2020 1815 13505.00 11 Operating Weight Kg 3350 6630 4310 3700 3930 3495 25415.00 12 Testing Weight Kg 2850 12000 11930 11450 11550 11615 61395.00 13 Shut Down weight kg 3350 3400 2920 3020 2715 18505.00 3100 Calculation is based on a Erection Weight : 3 + 4 +5 Kg 13505.00 b Operating Weight : 3 + 4 +5+6+7+9 Kg 25415.00 c Test weight : 3 + 4 + 5 +6+8 Kg 61395.00 d Shut Down weight : 3 + 4 + 5 + 6 +9 Kg 18505.00 1 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss WIND MOMENT CALCULATION CODE IS : 875 Do Vessel Outside Diameter In Insulation Thickness 1.512 Met De Effective Vessel diameter = ( De + 2. In) Site Near Mumbai Vb Basic Wind speed (From IS : 875 for site near Mumbai) K1 Risk Factor K2 Terrain Height Factor 0.1 Met 1.712 Met 40 ,m/s 1 Level - I 1 Level - II 1 Level - III 1 Level - IV 1 Level - V 1 Level - VI 1 K3 Topography Factor 1.0 Vz Design Wind speed ; ( Vb . K1. K2 . K3 ) m/Sec Pz Wind Pressure ; ( 0.6. Vz2 ) / 9.81 Kg / m2 H Height of each section Met Af Cross section area subjected to wind load m2 Fx Wind Load ; ( Pz . Af ) hi Height from base to plane under consideration hx Height from base to C.G of respective section V Total Shear load Mb met met Fx Moment at the base Fx . Hx 5091.39 Kg. 77363.7282 Kg.met Mb Mt LEVELS 559271.675 lb.ft Mb - hi . [ V -( 0.5. Pz. De . hi ) ] Vz Pz m/sec Kg/m2 Kg.met De H Af Fx hi hx met m2 Kg met met Fx. Hx Mt Mt Kg. Met lb. Ft VI 40.00 97.86 1.712 5.39 9.23 903.01 25.00 27.695 25008.9881 2433.6242299694 V 40.00 97.86 1.712 5.00 8.56 837.68 20.00 22.500 18847.7064 9042.8866152905 65372.11 IV 40.00 97.86 1.712 5.00 8.56 837.68 15.00 17.500 14659.3272 19840.528205505 143429.56 III 40.00 97.86 1.712 5.00 8.56 837.68 10.00 12.500 10470.948 34826.549000612 251765.30 II 40.00 97.86 1.712 5.00 8.56 837.68 5.00 7.500 6282.56881 54000.949000612 390379.34 I 40.00 97.86 1.712 5.00 8.56 837.68 0.00 2.500 2094.1896 77363.728205505 559271.67 V 5091.39 Mb 17592.96 77363.7282 2 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss SEISMIC MOMENT CALCULATION FIND OUT BASE SHEAR ; ( Vh ) (As per procedure given in IS:1893-2002) SITE MUMBAI, INDIA ZONE III Z ZONE FACTOR I IMPORTANCE FACTOR (Table - 6 - IS:1893-2002) 1 R RESPONSE REDUCTION FACTOR (Table - 7 - IS:1893-2002) 4 Sa/g AVERAGE RESPONSE ACCELERATION CO-EFFICIENT 0.16 2.5 Cl. 6.4.5 - IS:1893 - 2002, Soil - Medium soil sites Ah DESIGN HORIZONTAL ACCELERATION SPECTRUM Ah (Z x I ) / ( R x (Sa/g)) Wo Total Weight of vessel , Operating 0.016 25415.00 lb 56014.66 lb Vh Horizontal Seismic Force ; ( Ah . Wo ) H Overall Height of vessel D Uniform column Diameter t Thickness of shell 0.2362205 in ht (2/3).H 597.48971 feet T Period of Vibration = 0.0000265 . ( H/ D)2 . (Wo. D / ht ) 0.5 Ft 896.23 lb 99.6792 feet 5.61536 feet 0.2070943 Sec Lesser of followings 0.07 . T. Vh 12.992353 lb 0.25*Vh 224.05864 lb Ft Governing 12.992353 lb F Lateral Force applied at C.G of vessel ; ( Vh - Ft ) 883.24 lb Mb' Overturning Moment at base ; ( Ft . H) + 2/3 . (F. H) 59988.985 lb. Ft Comparing Mb & Mb' -- Governing Moment is effective due to wind. Use Mb for further calculation. 3 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN COMBINED STRESS ANALYSIS COMBINED STRESS ANALYSIS TO BE CARRIED OUT FOR FOLLOWING CONDITION A ERECTION CONDITION B OPERATING CONDITION C TESTING CONDITON STRESS SHALL BE CALCULATED INDUCED DUE TO A B C DEAD WEIGHT INTERNAL PRESSURE WIND OR SEISMIC EFFECT xt xc Longitudinal stress, Tension ( Pi . D / 4 t ) + (48. Mt / pi . D2. t ) - ( Wh/ Pi. D. t) Longitudinal stress, Compression ( - ) ( Pe. D / 4 t ) - (48. Mt / pi . D2. t ) - ( Wh/ Pi. D. t) LOADING CONDTION : ERECTION LEVELS Weight of each Section VI lb 4000.26 Shear Load Wh lb 4000.26 Mt D t (New) xt Allowable Limit S1E1 Allowable Limit Factor B lb.ft 17592.96 in 59.53 in 0.236 PSI 230.62 PSI 17000 PSI -411.76 PSI -11000.00 xc V 4452.08 8452.34 65372.11 59.53 0.236 1002.10 17000 -1384.84 -11000.00 IV 4452.08 12904.42 143429.56 59.53 0.236 2326.36 17000 -2910.70 -11000.00 III 5289.6 18194.02 251765.30 59.53 0.236 4184.44 17000 -5008.31 -11000.00 II 5289.6 23483.62 390379.34 59.53 0.315 4946.48 17000 -5744.02 -11000.00 I 6281.4 29765.02 559271.67 59.53 0.472 4768.24 17000 -5442.15 -11799.97 NOTE EFFECT DUE TO INTERNAL AND EXTERNAL PRESSURE TO BE IGNORED DURING ERECTION STAGE ALLOWABLE STRESS CALCULATED AT AMBIENT CONDITION WELD EFFICIENTY : 0.85 LOADING CONDTION : SHUTDOWN LEVELS Weight of each Section lb lb lb.ft in in VI 5983.86 5983.86 17592.96 59.53 0.177 V 6656.08 12639.94 65372.11 59.53 0.177 IV 6435.68 19075.62 143429.56 59.53 III 7493.60 26569.22 251765.30 II 6832.40 33401.62 I 7383.40 40785.02 NOTE Shear Load Wh Allowable Limit S1E1 xc Allowable Limit Factor B PSI PSI PSI PSI 247.61 17000 -608.89 -11000.00 1209.72 17000 -1972.87 -11000.00 0.177 2915.52 17000 -4067.24 -11000.00 59.53 0.177 5326.43 17000 -6930.57 -11000.00 390379.34 59.53 0.256 5880.69 17000 -7276.84 -11000.00 559271.67 59.53 0.413 5306.84 17000 -6362.18 -11799.97 Mt D t (Corroded) xt EFFECT DUE TO INTERNAL AND EXTERNAL PRESSURE TO BE IGNORED DURING ERECTION STAGE ALLOWABLE STRESS CALCULATED AT AMBIENT CONDITION WELD EFFICIENTY : 0.85 LOADING CONDTION : OPERATING LEVELS Weight of each Section lb lb lb.ft in in VI 7702.98 7702.98 17592.96 59.53 0.177 V 8661.72 16364.70 65372.11 59.53 0.177 IV 8154.80 24519.50 143429.56 59.53 III 9499.24 34018.74 251765.30 II 14612.52 48631.26 I 7383.40 56014.66 NOTE Shear Load Wh Allowable Limit S1E1 xc Allowable Limit Factor B PSI PSI PSI PSI 699.71 14875 -744.79 -11000.00 1601.28 14875 -2169.31 -11000.00 0.177 3255.18 14875 -4315.58 -11000.00 59.53 0.177 5605.54 14875 -7239.46 -11000.00 390379.34 59.53 0.256 5911.32 14875 -7653.28 -11000.00 559271.67 59.53 0.413 5325.81 14875 -6595.21 -11799.97 D t (New) xt Allowable Limit S1E1 xc Allowable Limit Factor B PSI PSI Mt D t (Corroded) xt ALLOWABLE STRESS CALCULATED AT DESIGN TEMPERATURE. WELD EFFICIENTY : 0.85 LOADING CONDTION : TEST LEVELS Weight of each Section lb lb lb.ft in in PSI PSI VI 25599.46 25599.46 17592.96 59.53 0.236 342.55 14875 -258.41 -11000.00 V 25456.20 51055.66 65372.11 59.53 0.236 669.98 14875 37.52 -11000.00 IV 25235.80 76291.46 143429.56 59.53 0.236 1555.17 14875 891.22 -11000.00 III 26293.72 102585.18 251765.30 59.53 0.236 2969.20 14875 2273.74 -11000.00 II 26448.00 129033.18 390379.34 59.53 0.315 3699.38 14875 3154.16 -11000.00 I 6281.40 135314.58 559271.67 59.53 0.472 3952.59 14875 3573.36 -11799.97 NOTE Shear Load Wh Mt ALLOWABLE STRESS CALCULATED AT DESIGN TEMPERATURE. WELD EFFICIENTY : 0.85 HYDROSTATIC TEST PRESSURE IS 1.5 TIMES DESIGN PRESSURE + EFFECT DUE TO STATIC HEAD SUCH BIG COLUMN HYDROTESTD IN HORIZONTAL CONDITION IN WORKSHOP EXTERNAL PRESSURE WILL BE ZERO IN ABOVE CALCULATION CONCLUSION STRESSES INDUCED DURING DIFFERENT CONDITIONS ARE WELL WITHIN IN ALLOWABLE LIMITED AND HENCE PROVIDE THICKNESS ARE ADEQUATE 4 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss ANCHOR BOLT CALCULATION - EQUIVALENT AREA METHOD REFER TABLE 3.33 FOR NO. OF BOLTS SHELL O/D N 8 Nos RECOMMENDED MAXIMUM NO.OF ANCHOR BOLTS 12 Nos. NO. OF BOLTS ASSUMED MATERIAL OF CONSTRUCITON FOR ANCHOR BOLTS Fs Fc n Mb Wb d r w 59.45 in RECOMMENDED MINIMUM NO.OF ANCHOR BOLTS ALLOWABLE TENSILE STRESS FOR ANCHOR BOTLS, (REFER TABLE 3.34) ALLOWABLE COMPRESSIVE STRESS FOR CONCRETE, (REFER TABLE 3.35) RATIO OF MODULUS OF ELASTICITY OF STEEL TO CONCRETE (REFER TABLE 3.35) OVERTURNING MOMENT DUE TO WIND WEIGHT OF VESSEL AT BASE - TEST WEIGHT OUTSIDE DIAMETER OF SKIRT OUTSIDE RADIUS OF SKIRT WIDTH OF BASE PLATE 12 Nos. SA36 19000 PSI 1000 PSI 12 559271.67 135314.58 64.00 32.00 5.00 lb.ft lb in in in APPROXIMATE VALUE OF ' K ' K [ 1 / ( 1 + (Fs / n.Fc))] 0.387 CO-EFFICIENT FROM CHART Cc 1.64 Ct 2.33 J 0.783 Z 0.427 TENSILE LOAD IN STEEL ; ( T ) T (Mb - Wb - Z.d )/ J.d 8459.65 lb REQUIRED ROOT AREA ; (Ab) Ab ( T. pi . d / Fs . r . Ct ) ROOT AREA OF ONE BOLT : Ab / N Ra PROVIDED ROOT AREA 1.200 in2 0.1000 in2 0.302 in2 SELECTED BOLT DIAMETER : 0.75" HENCE OK STRESS IN EQUIVALENT STEEL BAND ; ( ts ) ts ( N. Ra ) / ( pi. d ) 0.0180 in EQUIVALENT TENSILE STRESS IN ANCHOR BOLT ; ( fs ) fs T / (ts . r . Ct ) 6293.7 PSI COMPRESSIVE LOAD IN CONCRETE ; ( C ) C T + Wb 143774.23 lb EQUIVALENT COMPRESSIVE STRESS IN CONCRETE ; ( fc ) fc C / ([ (w - ts )+n. ts].r.Cc ) 527.02 lb RECHECKING ' K ' USING ACTUAL' fs' and ' fc' K [ 1 / ( 1 + (fs / n.fc))] 0.501 lb SINCE THIS VALUE OF ' K ' IS DIFFERENT THAN THAT WAS ASSUMED. HENCE RECALCULATE 5 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss ANCHOR BOLT CALCULATION - EQUIVALENT AREA METHOD TRIAL - 2 APPROXIMATE VALUE OF ' K ' w WIDTH OF BASE PLATE K RATIO OF MODULUS OF ELASTICITY OF STEEL TO CONCRETE (REFER TABLE 3.35) CO-EFFICIENT FROM CHART n 5.50 in 0.300 12 Cc 1.51 Ct 2.442 J 0.781 Z 0.438 TENSILE LOAD IN STEEL ; ( T ) T (Mb - Wb - Z.d )/ J.d 8481.3 lb REQUIRED ROOT AREA ; (Ab) Ab ( T. pi . d / Fs . r . Ct ) ROOT AREA OF ONE BOLT : Ab / N Ra PROVIDED ROOT AREA 1.148 in2 0.0957 in2 0.302 in2 SELECTED BOLT DIAMETER : 0.75" HENCE OK STRESS IN EQUIVALENT STEEL BAND ; ( ts ) ts ( N. Ra ) / ( pi. d ) 0.0180 in EQUIVALENT TENSILE STRESS IN ANCHOR BOLT ; ( fs ) fs T / (ts . r . Ct ) 6020.4 PSI COMPRESSIVE LOAD IN CONCRETE ; ( C ) C T + Wb 143795.88 lb EQUIVALENT COMPRESSIVE STRESS IN CONCRETE ; ( fc ) fc C / ([ (w - ts )+n. ts].r.Cc ) 522.24 lb RECHECKING ' K ' USING ACTUAL' fs' and ' fc' K [ 1 / ( 1 + (fs / n.fc))] 0.510 lb NOW CALCULATED VALUE OF 'K' IS VERY CLOSE TO ASSUMED VALUE AND SIZING IS ADEQUATE SUMMARY db SIZE OF BOLT DIAMTER N NO. OF BOLTS w WIDTH OF BASE PLATE MOC OF SELECTED BOLTS 0.75 in 8 Nos. 5.50 in SA36 6 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss DESIGN OF ANCHOR CHAIR SELECTED TYPE OF ANCHOR CHAIR - TYPE -3 R tsk OUTSIDE RADIUS OF SKIRT SHELL SKIRT SHELL THICKNESS 30.000 in 0.472 in a 2 in c 1.5 in e c - (db/2) h 1.125 in 12 in l a+c tc COMPRESSION PLATE THICKNESS 1.00 in tb BASE RING THICKNESS 1.00 in w Width of Base Ring b SPACING BETWEEN TWO GUSSETS 3.5 in 5.5 in 2.500 in A COMPRESSION PLATE WIDTH tg GUSSETS THICKNESS 4.5000 in 0.5 in 64 in d BOLT CIRCLE DIAMETER N NO.OF ANCHOR BOLTS db DIAMTER OF BOLT HOLE IN BASE PLATE bs SPACING BETWEEN ANCHOR CHAIR 21.63 in Fs ALLOWABLE TENSILE STRESS FOR ANCHOR BOTLS, (REFER TABLE 3.34) 19000 PSI Ra PROVIDED ROOT AREA 0.302 in2 8 Nos. 1.75 in 7 OF 8 SUVIDYA INSTITUTE OF TECHNOLOGY Mumbai : 400055 SAMPLE DESIGN CALCULATION - SKIRT SUPPORT DESIGN OF VERTICAL COLUMN REFERENCE Pressure Vessel Design Manual by Dennis R. Moss DESIGN OF ANCHOR CHAIR BASE PLATE DESIGN - TYPE 3 CHECKING THICKNESS BETWEEN TWO GUSSETS MAXIMUM ANCHOR BOLT FORCE ; (P) P Fs . Ra 5738 lb BENDING MOMENT ; (Mo) Mo P. b / 8 1793.125 lb. in REQUIRED THICKNESS ; ( tb) tb [ ( 6 . Mo) / ( (w-db).Fs) ]0.5 0.389 in CHECKING THICKNESS BETWEEN TWO ANCHOR CHAIR RATIO l / bs 0.162 BENDING MOMENT PER UNIT LENGTH - REFER TABLE 3.36 Mx 0.00379. fc. b2 My -0.465. fc. l Mo GREATER OF Mx or My 12.37 lb. in -2974.83 lb.in 2 -2974.835 lb.in REQUIRED THICKNESS ; ( tb) tb [ ( 6 . Mo) / Fs ]0.5 0.969 in tb GREATER OF ABOVE 0.969 in PROVIDED BASE PLATE THICKNESS ; ( tb ) 1.00 in COMPRESSION PLATE THICKNESS CHECK - TYPE 3 MINIMUM THICKNESS OF TOP PLATE ; tc tc [ ( P / Fs. e )(0.375.b - 0.22 db) ]0.5 0.385 in PROVIDED TOP COMPRESSION PLATE THICKNESS ; (tc) 1.00 in GUSSET PLATE THICKNESS CHECK - TYPE -3 REQUIRED GUSSET THICKNESS ; ( tg ) tg P / ( 18000. l) > 3/8 " 0.0911 in PROVIDED GUSSET PLATE THICKNESS ; (tg) 0.50 in SKIRT SHELL THICKNESS CHECK - TYPE 3 Z 1 0.000732 [(1.77 . A. h2)/ (R. tsk)0.5] [(tb / tsk)2] + 1 424.00 PSI S SINCE S < 25000 PSI, HENCE PROVIDED SHELL THICKNESS IS ADEQUATE 8 OF 8