NCR SelfServ™ 22e ATM Site Preparation
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
The product described in this document is a licensed product of NCR
Corporation.
NCR and NCR SelfServ are trademarks of NCR Corporation. Other product
names mentioned in this publication may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged.
Where creation of derivative works, modifications or copies of this NCR
copyrighted documentation is permitted under the terms and conditions of an
agreement you have with NCR, NCR's copyright notice must be included.
It is the policy of NCR Corporation (NCR) to improve products as new
technology, components, software, and firmware become available. NCR,
therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed
by NCR in all parts of the world. In some instances, photographs are of
equipment prototypes. Therefore, before using this document, consult with
your NCR representative or NCR office for information that is applicable and
current.
NCR Proprietary Information ‐ not to be disclosed or reproduced without
written consent.
© 2010, 2012, 2013
by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.
All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Contents
Introduction
Audience ...............................................................................................1 ‐ 1
About This Document ...........................................................................1 ‐ 1
NCR Site Preparation Services Contact Information.............................1 ‐ 1
Revision Record ....................................................................................1 ‐ 1
i
Power Requirements
AC Power Requirements....................................................................... 6 ‐ 1
Input Voltage ........................................................................................ 6 ‐ 1
Grounding............................................................................................. 6 ‐ 1
Transient Protection............................................................................. 6 ‐ 1
Transient Protection Products......................................................... 6 ‐ 1
Customer Responsibilities
Notice ...................................................................................................2 ‐ 1
Site Compliance ....................................................................................2 ‐ 1
Customer Actions .................................................................................2 ‐ 1
Standards Compliance
Radio Frequency Interference ..............................................................3 ‐ 1
FCC Radio Frequency Interference Statement ................................3 ‐ 1
Canadian Class A Device Declaration...............................................3 ‐ 1
Safety ....................................................................................................3 ‐ 1
Safety Directive................................................................................3 ‐ 1
Harmonised Safety Standard...........................................................3 ‐ 1
Electromagnetic Compatibility (EMC)...................................................3 ‐ 1
Immunity Standards ........................................................................3 ‐ 1
EMC Directives.................................................................................3 ‐ 1
Emission Standards..........................................................................3 ‐ 1
Additional Requirements for 220V ‐ 240V Units .............................3 ‐ 1
Accessibility ..........................................................................................3 ‐ 1
Highest Operable Point ...................................................................3 ‐ 1
Product Overview
General Description ..............................................................................4 ‐ 1
Options ............................................................................................4 ‐ 1
Acoustics...............................................................................................4 ‐ 1
Heat Dissipation....................................................................................4 ‐ 1
Product Identification...........................................................................4 ‐ 1
Site Requirements
Positioning the ATM .............................................................................5 ‐ 1
Power Disconnect Device ................................................................5 ‐ 1
Floor......................................................................................................5 ‐ 1
Doorways and Corridors .......................................................................5 ‐ 1
Ambient Lighting...................................................................................5 ‐ 1
Task Lighting .........................................................................................5 ‐ 1
Barometric Pressure .............................................................................5 ‐ 1
Temperature and Humidity ..................................................................5 ‐ 1
Normal Operating Range (Interior Environment)............................5 ‐ 1
Storage Range (Up To Three Months) .............................................5 ‐ 1
Transit Range (Up To One Week) ....................................................5 ‐ 1
Extreme Power On Range (Up To One Hour) ..................................5 ‐ 1
Cable Requirements
Cable Preparation................................................................................. 7 ‐ 1
Data Line Transient Protection............................................................. 7 ‐ 1
Transient Protection Products......................................................... 7 ‐ 1
High Order Communications Standard Cable (RS‐232) ........................ 7 ‐ 1
RS‐232 Cable (9 pin) ............................................................................. 7 ‐ 1
Alarm Interface Cables ......................................................................... 7 ‐ 2
Basic Alarm Cable ............................................................................ 7 ‐ 2
Enhanced Alarm Cable .................................................................... 7 ‐ 2
Ethernet Standard Cable ...................................................................... 7 ‐ 3
Power Cable.......................................................................................... 7 ‐ 3
Decals
Decals ................................................................................................... 8 ‐ 1
Card Reader .......................................................................................... 8 ‐ 1
Decal Dimensions ............................................................................ 8 ‐ 1
Suggested Designs........................................................................... 8 ‐ 1
Receipt Exit ........................................................................................... 8 ‐ 1
Decal Dimensions ............................................................................ 8 ‐ 1
Suggested Designs........................................................................... 8 ‐ 1
Cash Exit ............................................................................................... 8 ‐ 2
Decal Dimensions ............................................................................ 8 ‐ 2
Suggested Designs........................................................................... 8 ‐ 2
Advert ................................................................................................... 8 ‐ 2
Without Camera Lens...................................................................... 8 ‐ 2
With Camera Lens ........................................................................... 8 ‐ 2
With Consumer Awareness Mirrors ................................................ 8 ‐ 2
With Camera Lens and Consumer Awareness Mirrors.................... 8 ‐ 2
Decal Placement ................................................................................... 8 ‐ 2
Variant Details ‐ CEN, Front Access
Package Dimensions ............................................................................. 9 ‐ 1
ATM Dimensions................................................................................... 9 ‐ 1
With Standard Top Box ................................................................... 9 ‐ 1
With Extended Top Box................................................................... 9 ‐ 1
Weight and Floor Loading .................................................................... 9 ‐ 1
Security Bolts........................................................................................ 9 ‐ 2
Bolt Holes ............................................................................................. 9 ‐ 2
Cable Entry ........................................................................................... 9 ‐ 2
Facia Items............................................................................................ 9 ‐ 3
Topmost Viewable Facia Item ......................................................... 9 ‐ 3
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
Heights and Depths ......................................................................... 9 ‐ 3
Distance for Voice Guidance ........................................................... 9 ‐ 3
Servicing Areas ‐ Optimum................................................................... 9 ‐ 4
Servicing Areas ‐ Minimum .................................................................. 9 ‐ 4
Clearances ‐ Corridor............................................................................ 9 ‐ 4
Surrounds and Enclosures .................................................................... 9 ‐ 4
Variant Details ‐ CEN, Rear Access
Package Dimensions........................................................................... 10 ‐ 1
ATM Dimensions ................................................................................ 10 ‐ 1
Weight and Floor Loading .................................................................. 10 ‐ 1
Security Bolts...................................................................................... 10 ‐ 2
Bolt Holes ........................................................................................... 10 ‐ 2
Cable Entry ......................................................................................... 10 ‐ 2
Facia Items ......................................................................................... 10 ‐ 3
Topmost Viewable Facia Item ....................................................... 10 ‐ 3
Heights and Depths ....................................................................... 10 ‐ 3
Distance for Voice Guidance ......................................................... 10 ‐ 3
Servicing Areas ‐ Optimum................................................................. 10 ‐ 4
Servicing Areas ‐ Minimum ................................................................ 10 ‐ 4
Clearances ‐ Corridor.......................................................................... 10 ‐ 4
Surrounds and Enclosures .................................................................. 10 ‐ 4
Variant Details ‐ UL, Front Access
Package Dimensions........................................................................... 11 ‐ 1
ATM Dimensions ................................................................................ 11 ‐ 1
UL 291 24 Hours Level 1................................................................ 11 ‐ 1
UL 291 Business Hours .................................................................. 11 ‐ 1
Weight and Floor Loading .................................................................. 11 ‐ 1
Security Bolts...................................................................................... 11 ‐ 2
Bolt Holes ........................................................................................... 11 ‐ 2
UL 291 24 Hours Level 1................................................................ 11 ‐ 2
UL 291 Business Hours .................................................................. 11 ‐ 2
Cable Entry ......................................................................................... 11 ‐ 2
Facia Items ......................................................................................... 11 ‐ 3
Topmost Viewable Facia Item ....................................................... 11 ‐ 3
Heights and Depths ....................................................................... 11 ‐ 3
Distance for Voice Guidance ......................................................... 11 ‐ 3
Servicing Areas ‐ Optimum................................................................. 11 ‐ 4
UL 291 24 Hours Level 1................................................................ 11 ‐ 4
UL 291 Business Hours .................................................................. 11 ‐ 4
Servicing Areas ‐ Minimum ................................................................ 11 ‐ 5
UL 291 24 Hours Level 1................................................................ 11 ‐ 5
UL 291 Business Hours .................................................................. 11 ‐ 5
Clearances ‐ Corridor.......................................................................... 11 ‐ 6
Packaged ATM............................................................................... 11 ‐ 6
Unpackaged ATM .......................................................................... 11 ‐ 6
Surrounds and Enclosures .................................................................. 11 ‐ 6
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Contents
ii
Variant Details ‐ UL, Rear Access
Package Dimensions ...........................................................................12 ‐ 1
ATM Dimension ..................................................................................12 ‐ 1
Weight and Floor Loading...................................................................12 ‐ 1
Security Bolts ......................................................................................12 ‐ 2
Bolt Holes............................................................................................12 ‐ 2
Cable Entry..........................................................................................12 ‐ 2
Facia Items..........................................................................................12 ‐ 3
Topmost Viewable Facia Item .......................................................12 ‐ 3
Heights and Depths .......................................................................12 ‐ 3
Distance for Voice Guidance .........................................................12 ‐ 3
Servicing Areas ‐ Optimum .................................................................12 ‐ 4
Servicing Areas ‐ Minimum.................................................................12 ‐ 4
Clearances ‐ Corridor ..........................................................................12 ‐ 4
Surrounds and Enclosures ..................................................................12 ‐ 4
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Introduction
1‐1
AUDIENCE
NCR SITE PREPARATION SERVICES CONTACT INFORMATION
This document is intended for architects and those responsible for preparing a
site prior to the arrival of the ATM.
For more information from NCR’s Site Preparation Services group on the
availability of power protection, data line transient suppressors, uninterruptible
power supply products, warranty or configuration assistance, call the
appropriate number below:
ABOUT THIS DOCUMENT
This site preparation document is designed to be read on wide aspect ratio
screens. Each section has been structured to fit the maximum amount of
information on the minimum number of pages yet still be readable when
printed on A3 size paper. Printing on smaller paper sizes may reduce readability
but will make handling easier.
Region
Telephone
USA and Canada
Europe, Middle East and Africa
Caribbean and Latin America
Asia Pacific
+1 800 257 0458
+97 1501405904 or 919-228-2412 (US)
+55 21 2540 0058
+91 93-80291285
REVISION RECORD
Date
Revision
March 2010
September 2010
December 2010
April 2012
A
B
C
D
September 2012
E
March 2013
F
July 2013
G
The document is organised into sections covering the following topics:












Introduction ‐ this section
Customer Responsibilities
Standards Compliance
Product Overview
Site Requirements
Power Requirements
Cable Requirements
Decals
Variant Details ‐ CEN, Front Access
Variant Details ‐ CEN, Rear Access
Variant Details ‐ UL, Front Access
Variant Details ‐ UL, Rear Access
Pages Reason for Change
All
Various
28
23, 24, 26
28
Various
New Publication
Added rear access variant, and CEN 1 security enclosure
Added wheelchair access
Added Contactless Card Reader
Removed wheelchair access
Added rear access CEN Grade 1
Updated front access pallet to three skids
All New A3 landscape format.
Added all requirements from NCR SelfServ™ 22, 22e, 25,
26, 28, 31, 36 Site Preparation Requirements, B006-6669.
9-2, 10-2, Updated security bolts specifications.
11-2, 12-2
Title Updated logos
3-1 Moved Immunity Standards from Safety to EMC
6-1 Updated Grounding
9-3, 10-3, Updated barcode shelf depth, was 44mm now 0 mm.
11-3, 12-3
Each page has two or three columns laid out as follows:
Publication name
Column 1
Copyright
Section number Page number
Section name
Column 2
Column 3
Publication ID
Where left and right side are stated the ATM is viewed from the front (facia
side) of the ATM. All plan views are top down unless otherwise stated.
Unless otherwise stated all dimensions are rounded to the nearest millimetre
and equivalent decimal of an inch.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Customer Responsibilities
NOTICE
SITE COMPLIANCE
This is a contractual document. It contains important warnings and confers
important legal rights and obligations. You are advised to read it carefully.
It is the responsibility of you, the customer, to assure that all installation
preparations are complete and in compliance with all specifications and
requirements of NCR and all applicable national, state, or local codes,
regulations and laws.
This equipment must be installed and used in strict accordance with the
manufacturer’s instructions. However, there is no guarantee that interference
to radio communications will not occur in a particular commercial installation. If
this equipment does cause interference, which can be determined by turning
the equipment off and on, the user is encouraged to consult an NCR service
representative immediately.
CAUTION
2‐1
NCR Corporation is not responsible for any radio or television
interference caused by unauthorized modifications of this
equipment or the substitution or attachment of connecting cables
and equipment other than those specified by NCR. Such
unauthorized modifications, substitutions, or attachments may
void the user’s authority to operate the equipment. The correction
of interference caused by such unauthorized modifications,
substitutions, or attachments will be the responsibility of the user.
This document contains the information necessary for the preparation of a site
conforming to NCR specifications. It is very important that the site complies
with the requirements specified in this document, because, once the
equipment has been installed, deficiencies in site preparation or the problems
caused by these deficiencies are much more difficult to detect and correct.
Further, failure to comply with these requirements or to take proper steps to
protect equipment against risks identified in this document may cause serious
damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical
wiring and mechanical systems must also comply with all relevant codes, laws
and regulations.
CUSTOMER ACTIONS
The customer must do or provide the following:



It is important that the site be prepared by a customer or his agent who is fully
conversant with the special requirements of electronic equipment. The
responsibility for ensuring that the site is prepared in compliance with this
document remains with the customer.

For information and guidance purposes only, a list is provided, in general terms,
of those matters for which the customer is responsible. This list is not intended
to be comprehensive, and in no way modifies, alters, or limits the responsibility
of the customer for all aspects of adequate site preparation.

NCR staff will be available to answer questions relating to the contents of this
document but, except where:
a. the customer has been notified that a full or partial consultancy service
is available and/or that NCR will be willing to undertake a preliminary or
final site survey and
b. the customer shall have entered into a formal contract with NCR for
provision of the same
no comment, suggestion or advice offered or not offered about preparation of
the site nor any inspection of the site whether before or after preparation is to
be taken as approval of the location of the site and equipment or of its
preparation and NCR will not be liable in respect of any comment, suggestion or
advice given by its staff or in respect of any failure to give advice.






When required by NCR, provide the NCR customer service
representative with appropriate drawings that indicate:
 Location of the equipment
 Site wiring (power and signal, paths and lengths)
 Location of other equipment capable of generating electrical noise,
electromagnetic interference, heat, etc.
Make building alterations necessary to meet wiring and other site
requirements.
Provide and install all communications cables, wall jacks, special
connectors, and associated hardware.
Provide and install necessary power distribution boxes, conduits,
grounds, lightning protection, and associated hardware.
Make sure all applicable codes, regulations and laws (including, but not
limited to, electrical, building, safety, and health) are met.
Provide and install auxiliary power or other equipment as required.
Provide storage or service areas as required.
Make sure the environmental requirements of the system/unit are met.
Provide floor coverings and environmental systems that limit or control
static electricity build‐up and discharge.
Install the product at a height which meets the accessibility regulations
of the relevant country.
Early SelfServ 22e ATMs do not have a power disconnect device (e.g.
on/off switch). If the ATM does not have the power switch, as shown in
Power Disconnect Device in the Running H/F 2 section, then an easily
accessible, switchable, mains socket is required to allow safe isolation
from the power supply, resetting and power cycling of the ATM.
Finally, only the customer can know the full extent of damage which may be
caused to his business by reason of failure of the equipment which is to be
installed. For this reason it is the customer’s responsibility to ascertain the
extent of any such possible damage to his existing or planned business, and to
effect, full insurance in respect of it.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Standards Compliance
RADIO FREQUENCY INTERFERENCE
3‐1
ELECTROMAGNETIC COMPATIBILITY (EMC)
ACCESSIBILITY
FCC Radio Frequency Interference Statement
Immunity Standards
It is the responsibility of the owning institution to ensure that the heights from
the floor level to the facia items comply with any local regulations.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the Federal Communications
Commission (FCC) Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case you, the customer, will be required to correct the
interference at your own expense.
The ATM complies with the following requirements for radiated and conducted
immunity:
Highest Operable Point

As per the requirements of EN55024, the ATM complies with the requirements
of the following normative Immunity Standard:




Canadian Class A Device Declaration
This digital apparatus does not exceed the Class A limits for radio noise
emissions from digital apparatus set out in the Radio Interference Regulations
of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant
les limites applicables aux appareils numériques de la classe A prescrites dans le
Réglement sur le brouillage radioélectrique édicté par le ministère des
Communications du Canada.
SAFETY




EN 61000‐4‐2 Electrostatic Discharge
EN 61000‐4‐3 Radiated RF
EN 61000‐4‐4 Electrical Fast Transient/Burst
EN 61000‐4‐5 Surge
EN 61000‐4‐6 Conducted RF
EN 61000‐4‐8 Power Frequency Magnetic Field
EN 61000‐4‐11 Voltage Dips/Short Interruption.
The highest operable point is the height of the of the highest consumer
interface element when the ATM is in use. The top FDK of the 15.0 inch display
is considered to be the highest operable point of this ATM. Providing that the
software application is designed to NCR guidelines, this point also applies for
the touch screen variant.
EMC Directives
This equipment has been found to comply with the essential requirements of
EMC Directive 2004/108/EC, by testing to harmonized standard, EN55022and
EN55024. The equipment complies with the limits for a Class A digital device,
pursuant to EN55022.
The ATM complies with the following Electromagnetic Compatibility (EMC)
directives and standards for IT equipment:

Safety Directive
EN 55024 (1998)/+A1: 2001, A2: 2003

2004/108/EC ‘EMC Directive’
93/68/EEC ‘CE Marking Directive’.
Low Voltage Directive (LVD) 2006/95/EC.
Emission Standards
Harmonised Safety Standard

EN 60950‐1: ‘Information Technology Equipment ‐ Safety’.
The ATM complies with the following requirements for radiated and conducted
emissions:






EN 55022 (1998) Class A
FCC 47CFR Part 15. Class A
CISPR 22 Class A
AS/NZS 3548 Class A
GB 9254 Class A
CNS 13438 Class A.
Additional Requirements for 220V ‐ 240V Units
The ATM complies with the following requirements for conducted emissions:


EN 61000‐3‐2: 2000, Mains harmonics, Class A
EN 61000‐3‐3: 1995/+A1: 2001, Mains flicker.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Product Overview
GENERAL DESCRIPTION
The NCR SelfServ 22e is a free‐standing, interior ATM available in both front and
rear access variants.
4‐1
ACOUSTICS
For most variants the acoustics sound power does not exceed:


65 dB(A) when idle
68 dB(A) when operating.
PRODUCT IDENTIFICATION
The illustration below is typical of the layout of the product identification label
which is fixed inside the ATM.
NCR SelfServ ™ 22e
HEAT DISSIPATION
The NCR SelfServ product range is a flexible hardware platform. NCR
recommends that actual power measurements are taken and used to establish
the heat dissipation for specific hardware configurations. These measurements
should include any custom or third party features.
Where specific measurements are not available then, as a guide, 760 KJ/hour
can be used as an indicative heating load. This figure is based on an ATM in idle
mode, with a medium to high feature functionality configuration.
Heat dissipation figures are largely unaffected by transactional rates.
Class: XXXX
NCR Global Solutions Ltd.
Tracer: XX - XX
Vãc:
Made in UK
XX - XXXXXXXX
Hz: 50/60
XXX - XXXv
BANK EQUIPMENT
CLASSIFIED BY UNDERWRITERS
LABORATORIES INC. AS TO
ELECTRICAL FIRE, SHOCK AND
CASUALTY HAZARDS ONLY.
IN ACCORDANCE WITH UL60950-1
583R
Manufactured: Xxxxxx XXXX
Model: XXXX
Serial:
A: X.X
LR32207
C
US
ACN 000 003 592
Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le
ministère des Communications du Canada
Unless specified, all dimensions apply to both front and rear access ATMs.
Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J
Options
Access


Front
Rear
Security Enclosure




CEN Grade L
CEN Grade 1
UL 291 24 Hours Level 1
UL 291 Business Hours (front access only)
The product is identified by a class and a 4 digit model number. The serial
number is unique to each ATM. The tracer number is used to identify where the
ATM was built.
Please quote all of the serial and tracer numbers, including the prefix, when
making reference to the ATM.
Electrical rating information is also shown on the product label.
Top Box


Standard Top Box
Extended Top Box (front access CEN Grade L, CEN Grade 1 only)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Site Requirements
5‐1
POSITIONING THE ATM
DOORWAYS AND CORRIDORS
The SelfServ 22e is only suitable for installation in an interior environment. The
ATM must be positioned away from heat sources or any air conditioning
equipment.
Bright lights and windows behind the user may degrade camera performance.
Position the ATM away from direct sunlight.
Allow sufficient room for installation and servicing requirements.
BAROMETRIC PRESSURE
Make sure that doorways and corridors leading to your point of installation are
wide enough to allow the package to pass through, or make arrangements to
unpack the ATM and remove it from the palette in an area with sufficient
access then move it to the installation site.
Make sure that any corridors can support the weight of the ATM, including all
packaging and the pallet.
Corridor sizes and ATM weights can be found in the Variant Details section for
your ATM.
Power Disconnect Device

Operating/Transit Limits: 105 kPa (15.2 lb.F/in.) to 70 kPa (10.2 lb.F/in.)
Equivalent Altitude: Up to a maximum of 3000 m (9842.52 ft)
TEMPERATURE AND HUMIDITY
Continuous operating at or near the range limits, or in a location where the
temperature and humidity change beyond the specification, should be avoided.
Normal Operating Range (Interior Environment)
AMBIENT LIGHTING
CAUTION

Early SelfServ 22e ATMs do not have a power disconnect device
(e.g. on/off switch). If the ATM does not have the power switch
shown below then an easily accessible, switchable, mains socket is
required to allow safe isolation from the power supply, resetting
and power cycling of the ATM.

If the ATM is fitted with a camera, it is strongly recommended that there is a
minimum of 50 LUX lighting at floor level within the area illustrated below.


Temperature: 10oC to 40oC (50oF to 104oF)
Relative Humidity: 20% to 80%
Dew Point Temperature Restriction: 26oC (79oF) maximum
Storage Range (Up To Three Months)


Temperature: ‐10oC to 50oC (14oF to 122oF)
Relative Humidity: 10% to 90%
Transit Range (Up To One Week)


Temperature: ‐40oC to 60oC (‐40oF to 140oF)
Relative Humidity: 5% to 95%
Note: If an uninterruptible power supply (UPS) is fitted to the ATM, the
temperature during transit should not drop below ‐15oC (15oF).
1000 mm
(39.37 in.)
Extreme Power On Range (Up To One Hour)

Power Switch

1550 mm
(61.02 in.)
FLOOR
The ATM must be installed on a level, even, concrete or other noncombustible
surface. In locations where the floor may be uneven, it is recommended that a
steel plate is used under the ATM.
An antistatic floor covering should be used and must be of a type that will not
generate dust or fluff.
Temperature: 0oC to 45oC (32oF to 113oF)
Relative Humidity: 10% to 95%
TASK LIGHTING
A minimum of 200 lux is required for task lighting.
The ATM must be installed on a floor capable of supporting the maximum
weight including media. Only the maximum weight should be considered as
additional options may be added after installation. Floor loading is calculated by
dividing the maximum weight of the ATM by the surface area of the ATM base
in contact with the floor.
Service areas, ATM weights and floor loading can be found in the Variant Details
section for your ATM.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Power Requirements
AC POWER REQUIREMENTS
The maximum current requirements are:


10A at 120V
6.3A at 230V.
The maximum inrush current is 100A.
NCR does not recommend running an ATM with deposit devices without an
Uninterruptible Power Supply (UPS). Without a UPS, there is the potential for
customer’s cash to be retained in the device if there is a power failure.
INPUT VOLTAGE
The ATM can operate from the following input mains voltages:


90V to 136V at 50/60Hz
180V to 264V at 50/60Hz.
GROUNDING
6‐1
TRANSIENT PROTECTION
In the process of power distribution, transient electrical energy (including, but
not limited to, lightning strikes, intermittent short circuits, and switching
transients) can be introduced on to power lines. Such transient energy can be
very damaging to electronic hardware and can also cause data corruption.
Under these circumstances, NCR recommends the use of AC power transient
suppressors and data (communication) line transient suppressors. Such
protective devices are intended to guard against power and data line transients
that can result in hardware damage and various system or program errors.






Dissipate energy to match the appropriate application categories as
defined by ANSI/IEEE Standard C62.41, Guide on Surge Voltages in Low‐
Voltage AC Power Circuits.
Be of the voltage limiting (clipping), or tracking filter type. The
suppressor must not ‘clamp’ the voltage to zero, and must self‐recover
after the passage of the transient. The suppressor may be of the hybrid
type construction that makes use of various technologies in order to
meet speed and dissipation requirements.
Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive
indication of its failure such as a blown fuse or tripped breaker
Be listed by the accepted safety organization for the country involved
(e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local,
state, and national electrical codes and regulations.
Location Category
The normal and safe operation of this ATM is dependant on the above. Only
qualified personnel that meet local certification standards should be permitted
to ensure compliance.
Note that the building ground point can also affect data integrity. For additional
information refer to Data Line Transient Protection in the Cable Requirements
section.
NCR Site Preparation Services Contact Information is listed in the Introduction
section.
When power transient suppression is required, the suppressors used should
meet the following minimum requirements:
The ATM power requirements will normally permit it to operate within existing
wiring configurations and from existing mains outlets provided that:
the branch circuit of the distribution panel supporting the ATM is not
also used to support equipment with heavy inductive loads such as air
conditioners or AC motors.
other branch circuits on the same distribution panel do not support
such equipment.
the installation meets or exceeds the regulatory and local guidelines
with regard to electrical safety and all conductor sizing.
NCR provides a full range of both AC power and data line transient surge
suppressors to protect your ATM. For more information, please call NCR Site
Preparation Services for more information.
Improvement of any deficiencies in power quality is a customer responsibility.
Malfunction and/or component failure as a result of power quality problems
are/is not covered by NCR Corporation Maintenance Agreement. NCR accepts
no liability for any such occurrence nor for its consequences.
The ATM operates from a single phase, 3 wire supply: live, neutral and ground.

Transient Protection Products
Comparable to IEC
No 664 Category
B = Major feeders, short branch
circuits, and load centres
III
C = Service Entrance and run to
load centre
IV
Transient
Waveform
Amplitudes
Volts = 1.2 x 50  s
Current = 8 x 20  s
and
0.5  Rise - 100 kHz
Ringwave
Volts = 1.2 x 50  s
Current = 8 x 20  s
6kV
3kA
6kV
500A
10kV or more
10kA or more
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Cable Requirements
CABLE PREPARATION
NCR supply a power cable for the ATM. Other external cables are not supplied.
Specifications for these cables are given in this section.
7‐1
HIGH ORDER COMMUNICATIONS STANDARD CABLE (RS‐232)
The interconnecting cable to the remote modem should not exceed 12.2 m
(40.0 ft) in length and must conform to the following specification:
It is the customer’s responsibility to have any required external cables installed
and to make sure that all cable preparations comply with NCR specifications as
well as with all national, state or local telephone and telegraph regulations and
laws.
4
1, 2, 5, 6
RS‐232 CABLE (9 PIN)
The ATM can have up to two RS‐232 (9 pin) outlets. The cable for each outlet
should not exceed 12.24 m (40.16 ft) and must conform to the following
specification:
4
1, 2
3
3
When producing cables allow for 2.9 m (9.5 ft) of cable within the ATM.
DATA LINE TRANSIENT PROTECTION
Voltage transients, line noise, surges, sags, impulses, and spikes may be
experienced routinely or sporadically. When such phenomena occur the use of
protective devices may be required to ensure proper operation of the
equipment.
It is the responsibility of the customer to install and connect a data line
transient suppression system to correct or prevent any deficiencies. Such
systems must meet the following minimum requirements:


Be of the self‐recovering voltage limiting type. Exhibit a ‘short circuit’
mode upon its failure to ensure a positive indication of its failure. Insert
minimum inductive and capacity loading at the operating frequency. Be
installed in accordance with all applicable local, state, and national
electrical codes and regulations.
Protect the data port from damage in the presence of a data line
transient event as defined in IEC Standard 1000‐4‐5 (formerly IEC 801‐
5).
Transient Protection Products
NCR provides a full range of both AC power and data line transient surge
suppressors to protect your ATM. For more information, please call NCR Site
Preparation Services for more information.
NCR Site Preparation Services Contact Information is listed in the Introduction
section.
1. Connector, 9 way (NCR part no. 006-0010488).
2. Terminal wire, female (NCR part no. 009-0002640).
3. Cable, shielded multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
1. Connector, 25 Way (NCR part no. 006-0005897)
2. Terminal, wire, male (NCR part no. 009-0002642)
3. Cable, multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1
2
3
4
5
6
7
8
9
Chassis GND
TD.V
RD.V
RQS.V
RFS.V
DSR.V
SIG.GND
DCD
RXD
TXD
DTR
S-GND
DSR
R TS
CTS
RI
RLSD.V
Not used
Remove a 40 mm (1.6 in.) section of the outer sleeve, 2.5 m (8.2 ft.) from the
ATM end of the cable.
Not used
Not used
Not used
Take care not to cut through the cable shielding.
Not used
Not used
40 mm
(1.6 in.)
TSET.V
Not used
RSET.V
WCA.V
Not used
DTR.V
Not used
2.5 m
(8.2 ft.)
CI.V
Not used
EXT SET.V
WIN.V
Remove a 40 mm (1.6 in.) section of the outer sleeve, 2.5 m (8.2 ft.) from the
ATM end of the cable.
Take care not to cut through the cable shielding.
40 mm
(1.6 in.)
2.5 m
(8.2 ft.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Cable Requirements
ALARM INTERFACE CABLES
7‐2
Basic Alarm Cable
The ATM may optionally be configured to provide an alarm interface which
enables the ATM to be connected to an external local alarm system. The
interface may take the form of one of two options; a basic alarm system or an
enhanced alarm system.
Enhanced Alarm Cable
1, 2, 5, 6
1, 2, 5, 6
4
4
3
3
A stabilised, non‐interruptible power supply must be provided through the
external alarm system. The alarm interface cable wiring must conform to the
following specification:



12V +/‐ 2V dc
200mA maximum
Ripple, 5% maximum.
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Chassis GND
Not used
Not used
Not used
Not used
Not used
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Vibration/Heat Common
Not used
+12V
Not used
Not used
Not used
Not used
Not used
Not used
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
Vibration/Heat N.O.
Vibration/Heat N.C
Not used
+12V Return
Chassis GND
Not used
Test Transmitter A
Not used
Tamper Alarm N.O.
Tamper Alarm N.C
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Composite Attack Common
Not used
+12V
Not used
Not used
Not used
Test Transmitter B
Not used
Tamper Alarm Common
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
Composite Attack N.O.
Composite Attack N.C
Not used
+12V Return
* Optional
* Optional
Remove a 40 mm (1.6 in.) section of the outer sleeve, 200 mm (7.9 in.) from the
ATM end of the cable.
Remove a 40 mm (1.6 in.) section of the outer sleeve, 200 mm (7.9 in.) from the
ATM end of the cable.
Take care not to cut through the cable shielding.
Take care not to cut through the cable shielding.
40 mm
(1.6 in.)
200 mm
(7.9 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
40 mm
(1.6 in.)
200 mm
(7.9 in.)
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Cable Requirements
ETHERNET STANDARD CABLE
The ethernet standard cable must be fully shielded, 8 pin, category 5 compliant
and must not exceed 97 m (318.20 ft) in length.
7‐3
POWER CABLE
The ATM is supplied either as a 120V or a 220‐240V unit. 120V ATMs are
supplied with a power cable fitted with a NEMA type 5‐15P power source
connector. 220‐240V ATMs are supplied with an unterminated power cable.
Information about suitable power connectors is supplied with the accessories.
The power cable supplied is 3 m (9.84 ft) in length. If it is necessary to increase
this length to meet site requirements, then the extension must satisfy local or
country regulations.
WARNING This equipment must be earthed.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Decals
DECALS
This section provides specifications for the decals which you may wish to fit to
the front of your ATM.
The SelfServ 22e decal recesses are positioned over the arrow‐shaped Media
Entry and Exit Indicators (MEEIs), which illuminate to indicate the position of
the receipt, cash, and card slots. Decals should be made from a clear material,
that allows the light from the MEEIs to shine through, with white text or icons
that contrast against the dark background colour of the facia.
8‐1
CARD READER
RECEIPT EXIT
Decal Dimensions
Decal Dimensions
The card reader decal should be of the following dimensions.
The receipt exit decal should be of the following dimensions.
The shaded grey must be left clear to avoid obscuring the MEEI.
The shaded grey must be left clear to avoid obscuring the MEEI.
64.5 mm
(2.53 in.)
68 mm
(2.67 in.)
Decals can also, if required, be used as paint masks if the facia is to be Colour
Customised ‐ to avoid the MEEIs being painted over.
99.5 mm
(3.92 in.)
Diameter
Decals should be a maximum of 0.5 mm (0.02 in.) thick, and it is recommended
that they be made from transparent textured polycarbonate with 3M 467 High
Performance MP adhesive.
21.5 mm
(0.84 in.)
Icons or text on the decals should provide good contrast of at least 70%
between foreground (text/icon) and background.
Where text is used, a sans serif typeface, such as Tiresias, is recommended.
20 mm
(0.78 in.)
12 mm
(0.47 in.)
57 mm
(2.24 in.)
30 mm
(1.81 in.)
20 mm
(0.78 in.)
43mm
(1.69 in.)
9 mm
(0.35 in.)
19 mm
(0.75 in.)
9 mm
(0.35 in.)
Suggested Designs
12 mm
(0.47 in.)
30 mm
(1.18 in.)
Receipt
Suggested Designs
Card
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Decals
8‐2
CASH EXIT
ADVERT
DECAL PLACEMENT
The following illustrations show dimensions for an advert decal that can be
placed on the front of the product in the advert decal recess.
Decal Dimensions
The cash exit decal should be of the following dimensions.
Advert
Without Camera Lens
The shaded grey must be left clear to avoid obscuring the MEEI.
415 mm
(16.34 in.)
30 mm
(1.81 in.)
12 mm
(0.47 in.)
8 mm
(0.31 in.)
Radius in
4 corners
50 mm
(1.96 in.)
21.5 mm
(0.84 in.)
Receipt Exit
20 mm
(0.78 in.)
Card Reader
With Camera Lens
64.5 mm
(2.53 in.)
11 mm
(0.34 in.)
Cash Exit
415 mm
(16.34 in.)
8 mm
(0.31 in.)
Radius in
4 corners
50 mm
(1.96 in.)
Suggested Designs
31 mm
(1.22 in.)
Diameter
1 mm
(0.04 in.)
Cash
With Consumer Awareness Mirrors
314 mm
(12.36 in.)
8 mm
(0.31 in.)
Radius in
4 corners
50 mm
(1.96 in.)
With Camera Lens and Consumer Awareness Mirrors
314 mm
(12.36 in.)
8 mm
(0.31 in.)
Radius in
4 corners
50 mm
(1.96 in.)
31 mm
(1.22 in.)
Diameter
1 mm
(0.04 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Front Access
PACKAGE DIMENSIONS
9‐1
ATM DIMENSIONS
With Extended Top Box
With Standard Top Box
450 mm
(17.70 in.)
450 mm
(17.70 in.)
784 mm
(30.87 in.)
1612 mm
(63.46 in.)
815 mm
(32.09 in.)
with
barcode
reader
784 mm
(30.87 in.)
240 mm
(9.45 in.)
815 mm
(32.09 in.)
with
barcode
reader
80 mm
(3.15 in.)
3 places
900 mm
(35.43 in.)
720 mm
(28.35 in.)
261 mm
(10.30 in.)
240 mm
(9.45 in.)
899 mm
(35.39 in.)
1412 mm
(55.60 in.)
1179 mm
(46.42 in.)
1412 mm
(55.60 in.)
874 mm
(34.40 in.)
723 mm
(28.46 in.)
1668 mm
(65.67 in.)
110 mm
(4.33 in.)
110 mm
(4.33 in.)
240 mm
(9.45 in.)
674 mm
(26.50 in.)
674 mm
(26.50 in.)
80 mm
(3.15 in.)
3 places
WEIGHT AND FLOOR LOADING
CEN Grade L or CEN Grade 1
900 mm
(35.43 in.)
720 mm
(28.35 in.)
240 mm
(9.45 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
Maximum weight
Floor loading
520 kg
(1146.6 lb.)
1714 kg/m2
(351.1 lb./ft2)
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Front Access
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of
the bolt holes, using bolts with anchor washers as specified below. Bolts and
anchor washers are to be supplied by the owning organisation.
9‐2
BOLT HOLES
CABLE ENTRY
The ATM should be bolted to the floor or plinth, through all the holes marked
‘A’, using four bolts with anchor washers.
Make sure that the floor or plinth is capable of withstanding the loading
imposed by the anchor points for these bolts.
450 mm
(17.72 in.)
If an adjustable plinth is used, it must be bolted to the floor to the same
specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a
concrete floor is:


Bolts
 Type ‐ either resin anchor or shield anchor bolts
 Size ‐ M16 (5/8 in.)
 Minimum Length ‐ 150 mm (5.9 in.)
 Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
 Type ‐ flat, steel (as per DIN7349 or equivalent)
 Size ‐ M16 (5/8 in.)
 Outer diameter ‐ no greater than 40 mm (1.58 in.)
 Minimum thickness ‐ 6 mm (0.2 in.).
Note: Early UL 24hrs Level 1 installations used M12 (1/2 in.) bolts. If moving
the terminal to a new site then M16 (5/8 in.) bolts must be used to
meet the latest UL 24hrs Level 1 standard.
70 mm
(2.76 in.)
40 mm
(1.57 in.)
270 mm
(10.63 in.)
A
A
40 mm
(1.57 in.)
674 mm
(26.54 in.)
315 mm
(12.40 in.)
300 mm
(11.81 in.)
30 mm
(1.18 in.)
B
A
A
96 mm
(3.78 in.)
104 mm
(4.09 in.)
75 mm
(2.95 in.)
75 mm
(2.95 in.)
300 mm
(11.81 in.)
Hole A (Bolt Holes)
Hole B (Security Alarm Sensor Hole)
43.0 mm
(1.69 in.)
20.0 mm
(0.79 in.)
30 mm
(1.18 in.)
30 mm
(1.18 in.)
26.0 mm
(1.02 in.)
10 mm
(0.39 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Front Access
FACIA ITEMS
9‐3
Heights and Depths
Distance for Voice Guidance
Height
from base
of the ATM
Depth
from front
of cosmetic
door
1312 mm
(21.70 in.)
180 mm
(7.09 in.)
1220 mm
(48.00 in.)
143 mm
(5.63 in.)
Card Reader
2
181 mm
(7.13 in.)
Card Reader
1002 mm
(39.45 in.)
51 mm
(2.01 in.)
Contactless Card Reader
(on Facia)
4
262 mm
(10.31 in.)
Receipt
959 mm
(37.80 in.)
57 mm
(2.24 in.)
Audio Jack Plug
4
179 mm
(7.05 in.)
935 mm
(36.81 in.)
90 mm
(3.54 in.)
Cash Exit/Entry
6
173 mm
(6.81 in.)
897 mm
(35.31 in.)
0 mm
(0.00 in.)
Barcode Reader (shelf)
8
174 mm
(6.85 in.)
864 mm
(34.02 in.)
0 mm
(0.00 in.)
Receipt Exit
9
141 mm
(5.55 in.)
0 mm
(0.00 in.)
11
Contactless Card Reader (on Facia)
796 mm
(33.34 in.)
330 mm
(12.99 in.)
Cash Exit/Entry
792 mm
(31.18 in.)
21 mm
(0.82 in.)
Facia Item
Touchscreen Display
381 mm (15.0 in.)
5
JKL
Display
381 mm (15.0 in.)
S
5
JKL
PIN Pad
Top FDK
Number 5 key
Audio Jack Plug
Topmost Viewable Facia Item
Barcode Reader (shelf)
The following illustration shows the projected angle from the front of the ATM
facia to the topmost viewable facia item.
S
Centre of shelf
11 12 1
10
2
3
9
8
4
7 6 5
Facia Item
S
Display - Top left-hand FDK
381 mm (15.0 in.)
Top FDK
Distance from
No. 5 Key
52o
Touchscreen Display
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Front Access
9‐4
SERVICING AREAS ‐ OPTIMUM
SERVICING AREAS ‐ MINIMUM
The optimum servicing area provides the best access to the ATM for all
servicing and operation tasks.
CLEARANCES ‐ CORRIDOR
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing
area.
If the optimum area is not available, then refer to Servicing Areas ‐ Minimum.
However note that installing the ATM in the minimum servicing area may
increase the servicing and/or upgrading time over an ATM installed using the
optimum area.
Always leave as much space as possible around the ATM to facilitate safe
operation and servicing.
Wherever possible the ATM should be installed within the optimum servicing
area. Installing the ATM in the minimum servicing area may increase the
servicing and/or upgrading time.
The dimensions shown assume the ATM is being moved using equipment that
does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
If the minimum area is not available then consult your local service
representative. Every site is different and you may still be able to install the
ATM but with further increases to servicing and/or upgrading time.
A
B
If you install in the minimum area then note that doors can open, and devices
rack out, beyond the area shown. Always leave as much space as possible
around the ATM to facilitate safe operation and servicing.
B
500 mm
(19.68 in.)
450 mm
(17.72 in.)
526 mm
(20.71 in.)
265 mm
(10.43 in.)
500 mm
(19.68 in.)
38 mm
(1.50 in.)
38 mm
(1.50 in.)
38 mm
(1.50 in.)
712 mm
(28.03 in.)
208 mm
(8.19 in.)
C
38 mm
(1.50 in.)
712 mm
(28.03 in.)
Front of
Security
Enclosure
(with door
open)
Dispenser
2042 mm
(80.39 in.)
303 mm
(11.93 in.)
450 mm
(17.72 in.)
Front of
Security
Enclosure
(with door
open)
Packaged ATM
246 mm
(9.68 in.)
55 mm
(2.16 in.)
1612 mm
(63.46 in.)
900 mm
(35.43 in.)
1330 mm
(52.36 in.)
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
pallet, carton and lid
pallet and carton or
pallet without carton
735 mm
(28.94 in.)
841 mm
(33.00 in.)
1166 mm
(45.91 in.)
732 mm
(28.82 in.)
839 mm
(33.03 in.)
1165 mm
(45.87 in.)
With barcode reader
Without barcode reader
462 mm
(18.19 in.)
619 mm
(24.37 in.)
943 mm
(37.13 in.)
462 mm
(18.19 in.)
609 mm
(23.98 in.)
916 mm
(36.06 in.)
Unpackaged ATM
999 mm
(39.33 in.)
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
1450 mm
(57.09 in.)
SURROUNDS AND ENCLOSURES
CAUTION
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
Any surround or enclosure that sits on top of the ATM must be self
supporting.
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Rear Access
PACKAGE DIMENSIONS
10 ‐ 1
ATM DIMENSIONS
WEIGHT AND FLOOR LOADING
CEN Grade L or CEN Grade 1
Maximum weight
Floor loading
1616 mm
(63.62 in.)
560 kg
(1234.8 lb.)
1557 kg/m2
(318.6 lb./ft2)
947 mm
(37.28 in.)
978 mm
(38.50 in.)
with
barcode
reader
599 mm
(23.58 in.)
1405 mm
(55.31 in.)
361 mm
(14.21 in.)
801 mm
(31.54 in.)
1440 mm
(56.69 in.)
1412 mm
(55.60 in.)
874 mm
(34.41 in.)
1827 mm
(71.93 in.)
806 mm
(31.73 in.)
450 mm
(17.70 in.)
599 mm
(23.58 in.)
115 mm
(4.53 in.)
800 mm
(31.50 in.)
63 mm
(2.48 in.)
1405 mm
(55.31 in.)
801 mm
(31.54 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Rear Access
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of
the bolt holes, using bolts with anchor washers as specified below. Bolts and
anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading
imposed by the anchor points for these bolts.
10 ‐ 2
BOLT HOLES
CABLE ENTRY
The ATM should be bolted to the floor or plinth, through all the holes marked
‘A’, using four bolts with anchor washers.
33.0 mm
(1.23 in.)
100 mm
(3.94 in.)
132.5 mm 132.5 mm
(5.22 in.) (5.22 in.)
230 mm
(9.05 in.)
441.5 mm
(17.38 in.)
If an adjustable plinth is used, it must be bolted to the floor to the same
specification as the ATM.
A
The minimum specification for bolts and washers to secure the ATM to a
concrete floor is:


Bolts
 Type ‐ either resin anchor or shield anchor bolts
 Size ‐ M16 (5/8 in.)
 Minimum Length ‐ 150 mm (5.9 in.)
 Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
 Type ‐ flat, steel (as per DIN7349 or equivalent)
 Size ‐ M16 (5/8 in.)
 Outer diameter ‐ no greater than 40 mm (1.58 in.)
 Minimum thickness ‐ 6 mm (0.2 in.).
Note: Early UL 24hrs Level 1 installations used M12 (1/2 in.) bolts. If moving
the terminal to a new site then M16 (5/8 in.) bolts must be used to
meet the latest UL 24hrs Level 1 standard.
325.5 mm
(12.81 in.)
A
B
800 mm
(31.50 in.)
410 mm
(16.14 in.)
82.5 mm
(3.25 in.)
265 mm
(10.43 in.)
102.5 mm
(24.04 in.)
A
160 mm
(6.23 in.)
A
450 mm
(17.72 in.)
Hole A (Bolt Hole)
Hole B (Security Alarm Sensor Hole)
43 mm
(1.69 in.)
65 mm
(2.56 in.)
21 mm
(0.83 in.)
40 mm
(1.57 in.)
26 mm
(1.02 in.)
25 mm
(0.98 in.)
40 mm
(1.57 in.)
28 mm
(1.10 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Rear Access
FACIA ITEMS
10 ‐ 3
Heights and Depths
Distance for Voice Guidance
Height
from base
of the ATM
Depth
from front
of cosmetic
door
1312 mm
(21.70 in.)
180 mm
(7.09 in.)
1220 mm
(48.00 in.)
143 mm
(5.63 in.)
Card Reader
2
181 mm
(7.13 in.)
Card Reader
1002 mm
(39.45 in.)
51 mm
(2.01 in.)
Contactless Card Reader
(on Facia)
4
262 mm
(10.31 in.)
Receipt
959 mm
(37.80 in.)
57 mm
(2.24 in.)
Audio Jack Plug
4
179 mm
(7.05 in.)
935 mm
(36.81 in.)
90 mm
(3.54 in.)
Cash Exit/Entry
6
173 mm
(6.81 in.)
897 mm
(35.31 in.)
0 mm
(0.00 in.)
Barcode Reader (shelf)
8
174 mm
(6.85 in.)
864 mm
(34.02 in.)
0 mm
(0.00 in.)
Receipt Exit
9
141 mm
(5.55 in.)
0 mm
(0.00 in.)
11
Contactless Card Reader (on Facia)
796 mm
(33.34 in.)
330 mm
(12.99 in.)
Cash Exit/Entry
792 mm
(31.18 in.)
21 mm
(0.82 in.)
Facia Item
Touchscreen Display
381 mm (15.0 in.)
5
JKL
Display
381 mm (15.0 in.)
S
5
JKL
PIN Pad
Top FDK
Number 5 key
Audio Jack Plug
Topmost Viewable Facia Item
Barcode Reader (shelf)
The following illustration shows the projected angle from the front of the ATM
facia to the topmost viewable facia item.
S
Centre of shelf
11 12 1
10
2
3
9
8
4
7 6 5
Facia Item
S
Display - Top left-hand FDK
381 mm (15.0 in.)
Top FDK
Distance from
No. 5 Key
52o
Touchscreen Display
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ CEN, Rear Access
10 ‐ 4
SERVICING AREAS ‐ OPTIMUM
SERVICING AREAS ‐ MINIMUM
The optimum servicing area provides the best access to the ATM for all
servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing
area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum.
However note that installing the ATM in the minimum servicing area may
increase the servicing and/or upgrading time over an ATM installed using the
optimum area.
Always leave as much space as possible around the ATM to facilitate safe
operation and servicing.
CLEARANCES ‐ CORRIDOR
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing
area. Installing the ATM in the minimum servicing area may increase the
servicing and/or upgrading time.
The dimensions shown assume the ATM is being moved using equipment that
does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
If the minimum area is not available then consult your local service
representative. Every site is different and you may still be able to install the
ATM but with further increases to servicing and/or upgrading time.
A
B
If you install in the minimum area then note that doors can open, and devices
rack out, beyond the area shown. Always leave as much space as possible
around the ATM to facilitate safe operation and servicing.
B
1070 mm
(42.13 in.)
C
1500 mm
(59.05 in.)
Packaged ATM
900 mm
(35.43 in.)
Rear of
Security
Enclosure
(with door
open)
800 mm
(31.50 in.)
3630 mm
(142.90 in.)
800 mm
(31.50 in.)
500 mm
(19.68 in.)
Rear of
Security
Enclosure
(with door
open)
310 mm
(12.20 in.)
310 mm
(12.20 in.)
360 mm
(14.17 in.)
360 mm
(14.17 in.)
38 mm
(1.50 in.)
38 mm
(1.50 in.)
500 mm
(19.68 in.)
Front of
Security
Enclosure
(no cosmetic
panel)
2600 mm
(102.4 in.)
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
pallet and carton
pallet without
carton
818 mm
(32.20 in.)
1091 mm
(42.95 in.)
1662 mm
(65.43 in.)
813 mm
(32.01 in.)
1080 mm
(42.52 in.)
1642 mm
(64.65 in.)
813 mm
(32.01 in.)
1075 mm
(42.32 in.)
1629 mm
(64.13 in.)
Unpackaged ATM
Front of
Security
Enclosure
(no cosmetic
panel)
900 mm
(35.43 in.)
A
pallet, carton and lid
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
CEN Grade L or CEN Grade 1
with barcode reader
CEN Grade L or CEN Grade 1
without barcode reader
462 mm
(18.19 in.)
677 mm
(26.657 in.)
1089 mm
(42.87 in.)
462 mm
(18.19 in.)
665 mm
(26.18 in.)
1060 mm
(41.73 in.)
1330 mm
(52.36 in.)
1070 mm
(42.13 in.)
SURROUNDS AND ENCLOSURES
CAUTION
1450 mm
(57.09 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
Any surround or enclosure that sits on top of the ATM must be self
supporting.
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
PACKAGE DIMENSIONS
11 ‐ 1
ATM DIMENSIONS
UL 291 Business Hours
450 mm
(17.70 in.)
UL 291 24 Hours Level 1
450 mm
(17.70 in.)
754 mm
(29.68 in.)
1612 mm
(63.46 in.)
785 mm
(30.91 in.)
with
barcode
reader
764 mm
(30.08 in.)
240 mm
(9.45 in.)
795 mm
(31.30 in.)
with
barcode
reader
80 mm
(3.15 in.)
3 places
231 mm
(9.09 in.)
900 mm
(35.43 in.)
720 mm
(28.35 in.)
241 mm
(9.49 in.)
240 mm
(9.45 in.)
899 mm
(35.39 in.)
1412 mm
(55.60 in.)
874 mm
(34.40 in.)
1412 mm
(55.60 in.)
874 mm
(34.40 in.)
723 mm
(28.46 in.)
1668 mm
(65.67 in.)
84 mm
(3.31 in.)
84 mm
(3.31 in.)
240 mm
(9.45 in.)
670 mm
(26.40 in.)
680 mm
(26.80 in.)
80 mm
(3.15 in.)
3 places
WEIGHT AND FLOOR LOADING
900 mm
(35.43 in.)
720 mm
(28.35 in.)
Maximum weight
240 mm
(9.45 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
Floor loading
UL 291
24 Hours Level 1
UL 291 Business Hours
440 kg
(970.2 lb.)
1438 kg/m2
(294.5 lb./ft2)
270 kg
(595.4 lb.)
896 kg/m2
(183.4 lb./ft2)
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of
the bolt holes, using bolts with anchor washers as specified below. Bolts and
anchor washers are to be supplied by the owning organisation.
11 ‐ 2
BOLT HOLES
CABLE ENTRY
The ATM should be bolted to the floor or plinth, through all the holes marked
‘A’, using four bolts with anchor washers.
UL 291 24 Hours Level 1
Make sure that the floor or plinth is capable of withstanding the loading
imposed by the anchor points for these bolts.
450 mm
(17.72 in.)
If an adjustable plinth is used, it must be bolted to the floor to the same
specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a
concrete floor is:


Bolts
 Type ‐ either resin anchor or shield anchor bolts
 Size ‐ M16 (5/8 in.)
 Size ‐ M12 (1/2 in.) (UL 291 Business Hours only)
 Minimum Length ‐ 150 mm (5.9 in.)
 Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
 Type ‐ flat, steel (as per DIN7349 or equivalent)
 Size ‐ M16 (5/8 in.)
 Outer diameter ‐ no greater than 40 mm (1.58 in.)
 Minimum thickness ‐ 6 mm (0.2 in.).
Note: Early UL 24hrs Level 1 installations used M12 (1/2 in.) bolts. If moving
the terminal to a new site then M16 (5/8 in.) bolts must be used to
meet the latest UL 24hrs Level 1 standard.
70 mm
(2.76 in.)
40 mm
(1.57 in.)
250 mm
(9.84 in.)
A
40 mm
(1.57 in.)
A
680 mm
(26.77 in.)
315 mm
(12.40 in.)
300 mm
(11.81 in.)
30 mm
(1.18 in.)
Security Alarm
Sensor Hole
A
130 mm
(5.12 in.)
75 mm
(2.95 in.)
A
96 mm
(3.78 in.)
300 mm
(11.81 in.)
75 mm
(2.95 in.)
370 mm
(14.6 in.)
40 mm
(1.57 in.)
UL 291 Business Hours
40 mm
(1.57 in.)
195 mm
(7.68 in.)
A
A
670 mm
(26.40 in.)
400 mm
(15.7 in.)
A
75 mm
(2.95 in.)
A
450 mm
(17.70 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
FACIA ITEMS
11 ‐ 3
Heights and Depths
Distance for Voice Guidance
Height
from base
of the ATM
Depth
from front
of cosmetic
door
1312 mm
(21.70 in.)
180 mm
(7.09 in.)
1220 mm
(48.00 in.)
143 mm
(5.63 in.)
Card Reader
2
181 mm
(7.13 in.)
Card Reader
1002 mm
(39.45 in.)
51 mm
(2.01 in.)
Contactless Card Reader
(on Facia)
4
262 mm
(10.31 in.)
Receipt
959 mm
(37.80 in.)
57 mm
(2.24 in.)
Audio Jack Plug
4
179 mm
(7.05 in.)
935 mm
(36.81 in.)
90 mm
(3.54 in.)
Cash Exit/Entry
6
173 mm
(6.81 in.)
897 mm
(35.31 in.)
0 mm
(0.00 in.)
Barcode Reader (shelf)
8
174 mm
(6.85 in.)
864 mm
(34.02 in.)
0 mm
(0.00 in.)
Receipt Exit
9
141 mm
(5.55 in.)
0 mm
(0.00 in.)
11
Contactless Card Reader (on Facia)
796 mm
(33.34 in.)
330 mm
(12.99 in.)
Cash Exit/Entry
792 mm
(31.18 in.)
21 mm
(0.82 in.)
Facia Item
Touchscreen Display
381 mm (15.0 in.)
5
JKL
Display
381 mm (15.0 in.)
S
5
JKL
PIN Pad
Top FDK
Number 5 key
Audio Jack Plug
Topmost Viewable Facia Item
Barcode Reader (shelf)
The following illustration shows the projected angle from the front of the ATM
facia to the topmost viewable facia item.
S
Centre of shelf
11 12 1
10
2
3
9
8
4
7 6 5
Facia Item
S
Display - Top left-hand FDK
381 mm (15.0 in.)
Top FDK
Distance from
No. 5 Key
52o
Touchscreen Display
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
SERVICING AREAS ‐ OPTIMUM
11 ‐ 4
UL 291 Business Hours
UL 291 24 Hours Level 1
The optimum servicing area provides the best access to the ATM for all
servicing and operation tasks.
500 mm
(19.68 in.)
450 mm
(17.72 in.)
500 mm
(19.68 in.)
500 mm
(19.68 in.)
450 mm
(17.72 in.)
500 mm
(19.68 in.)
Wherever possible, the ATM should be installed within the optimum servicing
area.
If the optimum area is not available, then refer to Servicing Areas ‐ Minimum.
However, note that installing the ATM in the minimum servicing area may
increase the servicing and/or upgrading time over an ATM installed using the
optimum area.
38 mm
(1.50 in.)
718 mm
(28.27 in.)
Always leave as much space as possible around the ATM to facilitate safe
operation and servicing.
38 mm
(1.50 in.)
708 mm
(27.87 in.)
Front of
Security
Enclosure
(with door
open)
Front of
Security
Enclosure
(with door
open)
2038 mm
(80.24 in.)
2048 mm
(80.63 in.)
1330 mm
(52.36 in.)
1330 mm
(52.36 in.)
1450 mm
(57.09 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
1450 mm
(57.09 in.)
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
SERVICING AREAS ‐ MINIMUM
11 ‐ 5
UL 291 24 Hours Level 1
This is the minimum area required for operating and servicing the ATM.
38 mm
(1.50 in.)
If the minimum area is not available, then consult your local service
representative. Every site is different and you may still be able to install the
ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices
rack out, beyond the area shown. Always leave as much space as possible
around the ATM to facilitate safe operation and servicing.
Baseline for dimensions is either the front or the rear of the security enclosure
with the security enclosure door open as indicated by the dotted line.
526 mm
(20.71 in.)
265 mm
(10.43 in.)
Wherever possible, the ATM should be installed within the optimum servicing
area. Installing the ATM in the minimum servicing area may increase the
servicing and/or upgrading time.
UL 291 Business Hours
162 mm
(6.38 in.)
265 mm
(10.43 in.)
38 mm
(1.50 in.)
526 mm
(20.71 in.)
38 mm
(1.50 in.)
38 mm
(1.50 in.)
38 mm
(1.50 in.)
718 mm
(28.27 in.)
303 mm
(11.93 in.)
450 mm
(17.72 in.)
Front of
Security
Enclosure
(with door
open)
38 mm
(1.50 in.)
200 mm
(7.84 in.)
29 mm
(1.14 in.)
162 mm
(6.38 in.)
708 mm
(27.87 in.)
1618 mm
(63.70 in.)
900 mm
(35.43 in.)
303 mm
(11.93 in.)
450 mm
(17.72 in.)
Front of
Security
Enclosure
(with door
open)
200 mm
(7.84 in.)
84 mm
(3.31 in.)
1608 mm
(63.31 in.)
900 mm
(35.43 in.)
953 mm
(37.52 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
953 mm
(37.52 in.)
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Front Access
11 ‐ 6
CLEARANCES ‐ CORRIDOR
SURROUNDS AND ENCLOSURES
The dimensions shown assume the ATM is being moved using equipment that
does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
CAUTION
Any surround or enclosure that sits on top of the ATM must be self
supporting.
B
A
B
C
Packaged ATM
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
pallet, carton and lid
pallet and carton or
pallet without carton
735 mm
(28.94 in.)
841 mm
(33.00 in.)
1166 mm
(45.91 in.)
732 mm
(28.82 in.)
839 mm
(33.03 in.)
1165 mm
(45.87 in.)
Unpackaged ATM
UL 291 24 Hours Level 1
UL 291 Business Hours
With
Without
With
Without
barcode reader barcode reader barcode reader barcode reader
A
Doorway or straight
corridor
B
Corridor with corner
C
Rotation about centre
462 mm
(18.19 in.)
612 mm
(24.09 in.)
926 mm
(36.46 in.)
462 mm
(18.19 in.)
602 mm
(23.70 in.)
899 mm
(35.39 in.)
462 mm
(18.19 in.)
609 mm
(23.98 in.)
917 mm
(36.10 in.)
462 mm
(18.19 in.)
599 mm
(23.98 in.)
890 mm
(35.04 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Rear Access
PACKAGE DIMENSIONS
12 ‐ 1
ATM DIMENSION
WEIGHT AND FLOOR LOADING
UL 291 24 Hours Level 1
Maximum weight
Floor loading
1616 mm
(63.62 in.)
475 kg
(1047.4 lb.)
1319 kg/m2
(270.2 lb./ft2)
921 mm
(36.26 in.)
952 mm
(37.48 in.)
with
barcode
reader
599 mm
(23.58 in.)
361 mm
(14.21 in.)
1405 mm
(55.31 in.)
801 mm
(31.54 in.)
1440 mm
(56.69 in.)
1412 mm
(55.60 in.)
874 mm
(34.41 in.)
1827 mm
(71.93 in.)
806 mm
(31.73 in.)
450 mm
(17.70 in.)
599 mm
(23.58 in.)
115 mm
(4.53 in.)
800 mm
(31.50 in.)
37 mm
(1.46 in.)
1405 mm
(55.31 in.)
801 mm
(31.54 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Rear Access
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of
the bolt holes, using bolts with anchor washers as specified below. Bolts and
anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading
imposed by the anchor points for these bolts.
If an adjustable plinth is used, it must be bolted to the floor to the same
specification as the ATM.
12 ‐ 2
BOLT HOLES
CABLE ENTRY
The ATM should be bolted to the floor or plinth, through all the holes marked
‘A’, using four bolts with anchor washers.
33.0 mm
(1.23 in.)
230 mm
(9.05 in.)
82.5 mm
(3.25 in.)
441.5 mm
(17.38 in.)
The minimum specification for bolts and washers to secure the ATM to a
concrete floor is:


Bolts
 Type ‐ either resin anchor or shield anchor bolts
 Size ‐ M16 (5/8 in.)
 Minimum Length ‐ 150 mm (5.9 in.)
 Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
 Type ‐ flat, steel (as per DIN7349 or equivalent)
 Size ‐ M16 (5/8 in.)
 Outer diameter ‐ no greater than 40 mm (1.58 in.)
 Minimum thickness ‐ 6 mm (0.2 in.).
Note: Early UL 24hrs Level 1 installations used M12 (1/2 in.) bolts. If moving
the terminal to a new site then M16 (5/8 in.) bolts must be used to
meet the latest UL 24hrs Level 1 standard.
76 mm
(2.99 in.)
102.5 mm
(24.04 in.)
265 mm
(10.43 in.)
A
A
60 mm
(2.36 in.)
410 mm
(16.14 in.)
325.5 mm
(12.81 in.)
800 mm
(31.50 in.)
Security Alarm
Sensor Hole
204 mm
(8.03 in.)
160 mm
(6.23 in.)
A
A
450 mm
(17.72 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Rear Access
FACIA ITEMS
12 ‐ 3
Heights and Depths
Distance for Voice Guidance
Height
from base
of the ATM
Depth
from front
of cosmetic
door
1312 mm
(21.70 in.)
180 mm
(7.09 in.)
1220 mm
(48.00 in.)
143 mm
(5.63 in.)
Card Reader
2
181 mm
(7.13 in.)
Card Reader
1002 mm
(39.45 in.)
51 mm
(2.01 in.)
Contactless Card Reader
(on Facia)
4
262 mm
(10.31 in.)
Receipt
959 mm
(37.80 in.)
57 mm
(2.24 in.)
Audio Jack Plug
4
179 mm
(7.05 in.)
935 mm
(36.81 in.)
90 mm
(3.54 in.)
Cash Exit/Entry
6
173 mm
(6.81 in.)
897 mm
(35.31 in.)
0 mm
(0.00 in.)
Barcode Reader (shelf)
8
174 mm
(6.85 in.)
864 mm
(34.02 in.)
0 mm
(0.00 in.)
Receipt Exit
9
141 mm
(5.55 in.)
0 mm
(0.00 in.)
11
Contactless Card Reader (on Facia)
796 mm
(33.34 in.)
330 mm
(12.99 in.)
Cash Exit/Entry
792 mm
(31.18 in.)
21 mm
(0.82 in.)
Facia Item
Touchscreen Display
381 mm (15.0 in.)
5
JKL
Display
381 mm (15.0 in.)
S
5
JKL
PIN Pad
Top FDK
Number 5 key
Audio Jack Plug
Topmost Viewable Facia Item
Barcode Reader (shelf)
The following illustration shows the projected angle from the front of the ATM
facia to the topmost viewable facia item.
S
Centre of shelf
11 12 1
10
2
3
9
8
4
7 6 5
Facia Item
S
Display - Top left-hand FDK
381 mm (15.0 in.)
Top FDK
Distance from
No. 5 Key
52o
Touchscreen Display
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
B006‐6902‐G000
NCR SelfServ™ 22e ATM Site Preparation
Variant Details ‐ UL, Rear Access
12 ‐ 4
SERVICING AREAS ‐ OPTIMUM
SERVICING AREAS ‐ MINIMUM
The optimum servicing area provides the best access to the ATM for all
servicing and operation tasks.
Wherever possible the, ATM should be installed within the optimum servicing
area.
If the optimum area is not available, then refer to Servicing Areas ‐ Minimum.
However, note that installing the ATM in the minimum servicing area may
increase the servicing and/or upgrading time over an ATM installed using the
optimum area.
Always leave as much space as possible around the ATM to facilitate safe
operation and servicing.
CLEARANCES ‐ CORRIDOR
This is the minimum area required for operating and servicing the ATM.
Wherever possible, the ATM should be installed within the optimum servicing
area. Installing the ATM in the minimum servicing area may increase the
servicing and/or upgrading time.
The dimensions shown assume the ATM is being moved using equipment that
does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
If the minimum area is not available then consult your local service
representative. Every site is different and you may still be able to install the
ATM but with further increases to servicing and/or upgrading time.
A
B
If you install in the minimum area then note that doors can open, and devices
rack out, beyond the area shown. Always leave as much space as possible
around the ATM to facilitate safe operation and servicing.
B
1070 mm
(42.13 in.)
C
900 mm
(35.43 in.)
1500 mm
(59.05 in.)
Rear of
Security
Enclosure
(with door
open)
800 mm
(31.50 in.)
3630 mm
(142.90 in.)
800 mm
(31.50 in.)
Rear of
Security
Enclosure
(with door
open)
310 mm
(12.20 in.)
310 mm
(12.20 in.)
360 mm
(14.17 in.)
360 mm
(14.17 in.)
38 mm
(1.50 in.)
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
pallet, carton and lid
pallet and carton
pallet without
carton
818 mm
(32.20 in.)
1091 mm
(42.95 in.)
1662 mm
(65.43 in.)
813 mm
(32.01 in.)
1080 mm
(42.52 in.)
1642 mm
(64.65 in.)
813 mm
(32.01 in.)
1075 mm
(42.32 in.)
1629 mm
(64.13 in.)
Unpackaged ATM
Front of
Security
Enclosure
(no cosmetic
panel)
1330 mm
(52.36 in.)
2600 mm
(102.4 in.)
38 mm
(1.50 in.)
500 mm
(19.68 in.)
500 mm
(19.68 in.)
Packaged ATM
Front of
Security
Enclosure
(no cosmetic
panel)
900 mm
(35.43 in.)
1070 mm
(42.13 in.)
A
Doorway or straight corridor
B
Corridor with corner
C
Rotation about centre
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
UL 291 24 Hours Level 1
without barcode reader
462 mm
(18.19 in.)
667 mm
(26.26 in.)
1065 mm
(41.93 in.)
462 mm
(18.19 in.)
656 mm
(25.83 in.)
1037 mm
(40.83 in.)
SURROUNDS AND ENCLOSURES
CAUTION
1450 mm
(57.09 in.)
UL 291 24 Hours Level 1
with barcode reader
Any surround or enclosure that sits on top of the ATM must be self
supporting.
B006‐6902‐G000