37777-7-8811 • KO-08/07-12’ Printed in Germany ebm-papst ebm-papst ebm-papst Mulfingen GmbH & Co. KG St.Georgen GmbH & Co. KG Landshut GmbH Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25 D-74673 Mulfingen D-78112 St.Georgen D-84030 Landshut Phone +49 (0) 7938 / 81-0 Phone +49 (0) 7724 / 81-0 Phone +49 (0) 871/ 707-0 Fax +49 (0) 7938 / 81-110 Fax +49 (0) 7724 / 81-1309 Fax +49 (0) 871 / 707-465 info1@de.ebmpapst.com info2@de.ebmpapst.com info3@de.ebmpapst.com Centrifugal fans and blowers version 07 Centrifugal fans and blowers www.ebmpapst.com The engineer’s choice version 07 Centrifugal fans and blowers 4 – Company profile: ebm-papst – Our key to success General information General information – How to use this catalogue – How to order your ebm-papst product Centrifugal fans from ebm-papst are available with forward or backward curved blades. The AC centrifugal fans, backward curved 13 AC centrifugal fans and blowers, forward curved 91 Table of content EC centrifugal fans, backward curved 221 EC centrifugal fans for clean rooms, backward curved 405 EC centrifugal fans and blowers, forward curved 421 – Centrifugal fans and blowers, forward curved and single inlet – Centrifugal blowers, forward curved and dual inlet EC-SYSTEMS 517 – Options – Switch power supplies – External commutation electronics for rail technology – Temperature sensor / control module – Pressure control / selection module for 3 speeds EC centrifugal, backward – Centrifugal blowers, forward curved and dual inlet housing, while centrifugal fans are shipped without scrolls. EC centrifugal, backward for clean rooms single inlet integrating the external rotor motor into the impeller. "Blowers" refers to devices with scroll AC centrifugal, forward – Centrifugal fans and blowers, forward curved and outstanding feature of the external rotor motors is their compact, flat design, which results from Our complete range of blowers is available in AC and EC technology. AC centrifugal, backward – How to find your ebm-papst product EC centrifugal, forward – Interface converter / RS485 repeater – RS485 terminal box / hand-held control terminal – Speed setting – LISA control software / fan control software – HMS controller Zubehör 549 EC-SYSTEMS – Inlet nozzles – Guard grilles – Connection leads – Capacitors – Terminal boxes – Air filters Quiet movement – Motor protection switch Centrifugal fans with backward curved blades Centrifugal fans and blowers with forward – Star-delta switch / repair switch are used primarily for intake suction and do not curved blades always require a scroll housing. require a scroll housing. They have high Their characteristic features are a low noise Technology hydraulic efficiency. level, relatively small air flow with a high – Technical parameters & scope increase in static pressure, and space-saving – Impellers application. – Motors 571 Technology More power Accessories – Speed setting – Control technology Distributors, agencies and subsidiaries 610 2 3 Contacts is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG Centrifugal fans and blowers 4 – Company profile: ebm-papst – Our key to success General information General information – How to use this catalogue – How to order your ebm-papst product Centrifugal fans from ebm-papst are available with forward or backward curved blades. The AC centrifugal fans, backward curved 13 AC centrifugal fans and blowers, forward curved 91 Table of content EC centrifugal fans, backward curved 221 EC centrifugal fans for clean rooms, backward curved 405 EC centrifugal fans and blowers, forward curved 421 – Centrifugal fans and blowers, forward curved and single inlet – Centrifugal blowers, forward curved and dual inlet EC-SYSTEMS 517 – Options – Switch power supplies – External commutation electronics for rail technology – Temperature sensor / control module – Pressure control / selection module for 3 speeds EC centrifugal, backward – Centrifugal blowers, forward curved and dual inlet housing, while centrifugal fans are shipped without scrolls. EC centrifugal, backward for clean rooms single inlet integrating the external rotor motor into the impeller. "Blowers" refers to devices with scroll AC centrifugal, forward – Centrifugal fans and blowers, forward curved and outstanding feature of the external rotor motors is their compact, flat design, which results from Our complete range of blowers is available in AC and EC technology. AC centrifugal, backward – How to find your ebm-papst product EC centrifugal, forward – Interface converter / RS485 repeater – RS485 terminal box / hand-held control terminal – Speed setting – LISA control software / fan control software – HMS controller Zubehör 549 EC-SYSTEMS – Inlet nozzles – Guard grilles – Connection leads – Capacitors – Terminal boxes – Air filters Quiet movement – Motor protection switch Centrifugal fans with backward curved blades Centrifugal fans and blowers with forward – Star-delta switch / repair switch are used primarily for intake suction and do not curved blades always require a scroll housing. require a scroll housing. They have high Their characteristic features are a low noise Technology hydraulic efficiency. level, relatively small air flow with a high – Technical parameters & scope increase in static pressure, and space-saving – Impellers application. – Motors 571 Technology More power Accessories – Speed setting – Control technology Distributors, agencies and subsidiaries 610 2 3 Contacts is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG Company profile: ebm-papst The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 9,800 people – in Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and our unique range of products based on a quality standard that surpasses every other have made us what we are: world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving to arrive at the perfect application solution for a wide variety of different industries is what determines our daily work. Those who know us know the high standards we apply to our work and know our creed: to be as close to our customers as possible and to simply be the best in terms of innovation and reliability. Our headquarters in Mulfingen 4 General information AC centrifugal, forward AC centrifugal, backward clearance for serial production only after all the Rooted in ebm, PAPST and mvl, the three leading innovators in the desired characteristics have been determined to development and production of motors and fans, ebm-papst has be just right. established itself as the world market leader. Now as ever, our legendary Environmental care is another priority with inventive spirit shines through in products that set standards in many ebm-papst. This is why we have developed segments of industry worldwide. We are proud to say that despite difficult ou product line in EC technology, which makes competition, our performance has always been exemplary and outstand- for very low power consumption. Due to our ing – in business, in our personal relationship with our customers, and of manufacturing philosophy, there is absolute course with respect to technology and engineering. For decades, we have focus on environmental care in production, contributed to the world of air technology and drive engineering with recycling, waste and waste water disposal. EC centrifugal, backward for clean rooms Our history – Our drive EC centrifugal, backward Left: Our location in St. Georgen Right: Our location in Landshut To maintain this advantage in skills and knowledge to get maximum Global Domestic quality and thus the highest degree of customer satisfaction, our In order to be specialist for customised solutions employees around the world put their passion and dedication to work throughout the world, you need strong partners. for you. Global Domestic – i.e. being present all over the EC centrifugal, forward small revolutions and large milestones. individual country – is how we have established Our catalogues just list the results of our incessant efforts in R&D: ourselves in all important markets on this globe products of highest quality and reliability. After all, it is our passion to with our successful subsidiaries. And so you will constantly try something new and improve what we have. In doing so, always find ebm-papst close to home, speaking we take advantage of the latest development methods and state-of- your language, and knowing the demands of the-art technology and invest quite heavily in R&D facilities. Best of all, your markets. Besides, our worldwide produc- though, we rely on excellently trained and skilled engineers and tion alliance serves as a basis for competitive technicians to be at your service in R&D and Sales & Distribution. pricing. Our global services and logistic outlets, EC-SYSTEMS world and being a national company in each Passionately involved in R&D times and just-in-time delivery. our five factories in Germany or one of our eleven international production All our efforts are documented in a comprehen- sites, our products always have the same high level of quality. This quality sive quality management system, both for prod- control is something you can definitely rely on! And this across all levels ucts and services. Being certified as complying of production and throughout all processes: consulting customers, devel- with the tough requirements of the international opment, material selection through to picking certified, choice suppliers standards DIN EN ISO 9001, ISO/TS 16949-2 and on to the production of parts and final delivery. On top of this, our and of standard DIN EN ISO 14001 is just one products have to pass the most rigourous tests under all realistic operat- seal of approval we have received for our ing conditions: continuous stress test, salt spray test, vibration test, or unceasing efforts to provide only the best precision noise measuring, just to mention a few. And the product gets quality products and services. Technology This is our promise without any compromise. Whether produced in one of 5 Contacts Producing and safeguarding high-quality products and services Accessories i.e. IT networking, safeguard short reaction Our key to success Our innovations and technologies keep on turning into new industrial standards. This competitive capability can only be maintained by seeing ventilation as a whole: the interrelationship between, and thus the system of, motor engineering, aerodynamics, and electronics. These are our three core competencies, imminently connected and linked in each of our products. And so we handle air intelligently and quietly and continue to set new standards in drive technology. Our system solutions form the main part of our product range by now. And they will be our main key to success. Production Winding machine Motor engineering, aerodynamics, electronics Finally, intelligence will become the decisive Our drive is well known and famous with specialists: our external-rotor factor on all markets in future. After all, only in motor, which has made us world market leader – quietly, yet powerfully. connection with electronics can drive and air Being versatile as to integration, it is ideally suited to the most diverse flow – as a system solution – have an optimal applications. Based on this principle, we here at ebm-papst have devel- effect in a product or application. Interfaces are oped the widest range of fans and motor types in the world. And for hot avoided, and thus potential faults and failures. or aggressive blower mediums, the internal-rotor motor is the perfect complement. Setting new standards with EC technology Wherever intelligent air handling is required, Still, in drive engineering, certain applications simply require the internal- where energy consumption needs to be reduced rotor motor principle, and they are then realised with our motors specifi- and performance has to be maximised, there cally developed for such cases. Take, for instance, the steering support our EC motors are your reliable answer. They do motor in the automotive field developed as innovation in active steering. not waste financial or natural resources. Instead, they boost high efficiency, continuous Be it axial or centrifugal fans, centrifugal blowers, compact fans or controllability via analogue or digital inputs, tangential blowers: we always design fan blades, impeller blades and long and maintenance-free service life, and ducted housings with the specific application in mind. We strive to robustness. minimise noise and to optimise efficiency. This is the challenge that we have taken up and which we meet – working away powerfully and quietly. 6 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Left: Endurance test room Centre: Shaker Right: Measurement station EC centrifugal, forward Top: Betz manometer Left: Precision noise measurement lab – EC fan units for clean room technology. As the electronics are integrated and the unit is wired up completely and ready to plug in, EC-SYSTEMS there is no need for our customers to waste time and money on laborious wiring work. Without any problems, the ebm-papst EC technology allows you to realise industry providing optimal selection of the networked, bus-linked appliances, to integrate simple or complex controls air-conditioning unit in the car and, combined at low cost and to also realise time and again new, customised and with booster blowers, individual air-condition- complete solutions. Here, ebm-papst excels as competent development ing of each and every passenger seat. – EC gas blowers with commutation and know-how in R & D and production also being well documented in a few control electronics including a processor. hundred national and international patents. And there is also our ability They are developed in such a way as to to listen intently, to pay good attention to our customers and their make the blower premix the required amount demands – in order to come up with new and pioneering ideas, such as: of air with the gas. Aerodynamics with these blowers are adjusted in such a way as to Technology make these blowers ideal for use in very limited space at high back pressure. 7 Contacts partner, with our experience of more than 25 years and our excellent Accessories – Sensitive EC sensor fans for the automotive How to use this catalogue The ebm-papst catalogue combines a technical and a product-specific section. Technical section: General information on how to select and find ebm-papst products for your specific application is found in the chapters "Selection" (p. 10) and "Technical parameters" (p. 572). In case you require technical background information on ebm-papst product groups, simply turn to the chapters "Impellers" (p. 576), "Motors" (p.590) and "Control technology" (p. 594). Product-specific section: The product-specific section is organised according to product diameters, lines, materials and/or design principles. Headline The headline indicates which technology (AC or EC), which design AC centrifugal fans (centrifugal, axial, etc.), and which line (e.g. S-Range) the product belongs backward curved, 3-D, Ø 400 to. Impeller diameter or other features are also indicated. – Material: Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Number of blades: 6 Direction of rotation: Clockwise, seen on rotor Type of protection: IP 54 (acc. to EN 60529) Insulation class: "F" Mounting position: Any Condensate discharges: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings – – – – – – – – Part designation / Type A – axial fan S – axial fan with guard grille W – axial fan with wall ring Type Motor R4E 400 M4E 094-FA F A R4E 400 M4E 094-HA B subject to alterations 1~ 1~ 1~ 1~ Hz rpm W A µF/VDB 50 60 50 60 1355 1480 1370 1460 375 540 480 700 1.75 2.40 2.40 3.15 8.0 /400 8.0 /400 10.0 /450 10.0 /450 Capacitor VAC 230 230 230 230 Max. current draw (1) Nominal data Max. power input (1) 1) Type Speed/rpm (1) part number: Frequency 7 Curve 5 6 Nominal voltage ebm-papst products and serves as 123 4 Electr. connection This key designates and identifies all Perm. amb. temp. R 2 E 190 -AO 26 -05 °C p. 596 f. -40 to +60 -40 to +50 -40 to +80 -40 to +55 A2a) A2a) (1) Nominal data in operating point with maximum load V – axial combination R – centrifugal fan, single inlet G – centrifugal blower, single inlet (with scroll housing) M – motor P – pumps 2 [Pa] [in H O] 2,5 K – centrifugal combination 600 500 2,0 D – centrifugal blower, dual inlet (with scroll housing) 400 2) Number of poles (AC) / number of cores (EC) 2 2 300 1,0 2-, 4-, 6-, 8- and 12-pole (Z = 12) / 1- and 3-core 200 3) Type of motor 1 1 0,5 B A 100 D – 3-phase motor E – single-phase motor with capacitor 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz [CFM] [m3/h] 60 Hz G – EC motor S – shaded-pole motor 56 Q – square shaded-pole motor 4) Impeller diameter in mm 5) Key for mechanical design 6) Key for electrical design 7) Key for mechanical variants 8 n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1350 370 1.75 64 A 2 1380 331 1.58 65 B 1 1370 469 2.37 66 B 2 1390 430 2.17 68 Curves 1,5 B – centrifugal fan, dual inlet What a product page is made up of (reduced scale - 50%) General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward Inlet nozzle (long) e g 141.0 172.0 128.0 50.0 90.0 54476-2-4013 164.0 193.0 148.0 70.0 113.0 54476-2-4013 66 c ±1 22 d ±1 5 EC-SYSTEMS Ø 370 Ø 257 EC centrifugal, backward Free-blowing or at minimal backpressure AC products (from motor size 094) and EC products (AC-fed): In operating point at maximum load 60 All drawings represent the design principle and are not to scale. Dimensions are either given in the product drawing or, with varying dimensions, in the table of dimensions given above the drawing. Accessories g Depth of screw max. 12 mm b Mounting dimensions Ø Technology Ø7 Ø 5 11 55 0 10 57 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Indication of relevant accessories and additional information The pages indicated at the bottom refer to the accessories, e.g. inlet nozzles, guard grilles, wall rings, etc. for this particular product, 28 Contacts Ø404 Ø 124 Ø268 0 Ø 100 -0,4 ,3 M6 45˚ 2 Brass lead tips AC products (up to motor size 074) and EC products (DC-fed): Graphic rendition of products ±0 e Nominal data 11 50 90 5 and options. EC-SYSTEMS 8.8 d protection class, capacitor, product conforming to standards, approvals Accessories R4E 400-AP17 -06 c EMC, leakage current, motor protection, electrical connection, cable exit, as well as additional information (e. g. the connection diagram). Electr. connections p. 596 f. Technology 7.1 b discharge holes, mode of operation, design, bearing, technical equipment, Curves and operating points The diagram gives air performance curves pertaining to the product. Refer to the operating point table to the right for information on speed, power consumption, current draw, sound level or sound pressure level and overall efficiency of the impeller. 9 Contacts R4E 400-AR05 -06 Dimensions EC centrifugal, backward for clean rooms kg system of protection, insulation class, mounting position, condensate EC centrifugal, forward Mass of centrifugal fan Centrifugal fan material, number of blades, direction of air flow, direction of rotation, EC centrifugal, backward for clean rooms AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE AC centrifugal, forward – – – – Depending on the product, information is provided here on the following: EC centrifugal, forward General information Product description How to select your ebm-papst product Solutions for ventilation offered by ebm-papst In the field of ventilation, ebm-papst offers the perfect solution for a vast number of applications. Depending on motor, impeller and control technology, there is almost no limit to the number of possible combinations, thus making sure you can find the best solution for your application. Criteria for selection When selecting a fan for a specific application, these parameters play an important role: – Air flow with given back pressure – Voltage supply, divided into DC and AC voltage (1~, 3~) – Noise generation – Efficiency – Available mounting space Selecting a fan The following diagram shows the range of characteristic curves for the most important fan designs and serves as a helpful tool in preselecting a design on the basis of air flow and back pressure. [Pa] Characteristic curves of the various designs axial fans centrifugal fans, backward curved centrifugal blowers, single inlet centrifugal blowers, dual inlet diagonal fans 1200 1000 800 600 400 200 200 10 500 1000 2000 5000 10000 20000 50000 [m³/h] General information AC centrifugal, forward AC centrifugal, backward How to order your ebm-papst product Have you found the suitable ebm-papst product and would like to order it now? In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone. Checklist EC centrifugal, backward Don't know exactly which ebm-papst product you need to order? In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone. Our specialists in ventilation and drive technology – Part designation / type are always there to help you find the best solution for your specific – Quantity needed application. – Field of application – Impeller diameter make sure your ebm-papst contact has all the necessary information to – Air flow handle your enquiry as efficiently and quickly as possible. – Back pressure EC centrifugal, backward for clean rooms – Ambient conditions (humidity, temperature, climate) Using the questions provided in the checklist here as a guideline, you can – Voltage supply How your ebm-papst product is delivered EC centrifugal, forward In our order confirmation, you will find information on when, how and where to the delivery will be made. We deliver: – Ex works (excluding packaging) – Via freight carrier (we also use postal services for shipments EC-SYSTEMS up to 30 kg) All the other details such as packaging, freight, insurance and customs duty will be settled with your ebm-papst contact prior to the time we issue our order confirmation. Accessories For your nearest sales office, please turn to page 610. Is there anything else you need to know about your ebm-papst product? In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone. We have the answer to your problem and are always glad to be able to be of assistance. make sure your ebm-papst contact has all the necessary information to handle your enquiry as efficiently and quickly as possible. 11 Contacts Technology Using the questions provided in the checklist here as a guideline, you can 12 General information Ø 133 - Ø 355 14 AC centrifugal fans with sheet steel impeller Ø 250 - Ø 280 36 AC centrifugal fans with aluminium impeller Ø 310 - Ø 630 44 13 Contacts Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward AC centrifugal fans with plastic impeller AC centrifugal, forward AC centrifugal, backward AC centrifugal fans backward curved AC centrifugal fans backward curved, Ø 133 Electr. connection B Perm. amb. temp. M2E 052-BF Sound pressure level R2E 133 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 052-BF Power input R2E 133 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Partially cast in aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 240 280 290 345 2700 3200 2800 3300 25 28 24 27 0.11 0.13 0.11 0.13 1.0 /400 1.0 /400 1.0 /400 1.0 /400 53 56 56 60 -25 to +55 -25 to +65 -25 to +45 -25 to +60 A1) A1) subject to alterations 0,6 160 0,4 120 2 2 0,2 80 1 1 40 A 0 50 50 100 100 150 B 150 200 250 [CFM] 300 50 Hz 14 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2680 25 0.11 A 2 2680 25 0.11 B 1 2710 25 0.11 B 2 2700 26 0.12 2 [Pa] 200 0,8 240 [in H O] Curves General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST EC centrifugal, backward Dimensions Inlet nozzle (long) Centrifugal fan kg c R2E 133-BH66 -07 0.7 73.0 09566-2-4013 R2E 133-BH66 -05 0.7 91.0 09566-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – – Ø58 ±0,2 13 53,6 ±0,5 EC centrifugal, forward c ±1 EC-SYSTEMS 27,5 Ø129 Ø87 Ø133 Ø72 Ø92,8 8 15 Brass lead tips Accessories M4 6 3 ±2 41 2 60,6 Depth of screw max. 5 mm Technology 0 00 15 Inlet nozzle p. 550 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 60 AC centrifugal fans backward curved, Ø 133 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 60 280 320 2780 3200 36 34 0.25 0.21 Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R2S 133 M2S 052-CA 1~ 230 1~ 230 A — — 55 58 -25 to +40 -25 to +60 B) subject to alterations 2 [Pa] 200 0,8 240 [in H O] Curves 160 0,6 A 0,4 120 2 0,2 80 1 40 0 50 50 100 100 150 150 200 250 [CFM] 300 50 Hz 16 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2720 38 0.27 A 2 2720 38 0.27 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Inlet nozzle (long) R2S 133-AE17 -05 0.9 09566-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – 91±1 Ø58 ±0,2 EC-SYSTEMS 28,5 Ø129 Ø87 Ø133 Ø72 20 Ø92,8 8 EC centrifugal, forward 13 58 ±0,5 Brass lead tips M4 3 ±2 41 60,6 2 Depth of screw max. 5 mm Technology 0 00 17 Inlet nozzle p. 550 Electr. connections p. 596 f. Contacts 60 Accessories 6 AC centrifugal fans backward curved, Ø 175 Electr. connection B Perm. amb. temp. M2S 052-CA Sound pressure level R2S 175 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 052-CA Power input R2E 175 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: A IP 44, B IP 20 – Insulation class: A "F", B "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 490 570 440 430 2650 3100 2350 2300 50 51 53 51 0.25 0.23 0.33 0.29 1.5 /400 1.5 /400 — — 63 68 61 60 -25 to +50 -25 to +80 -25 to +40 -25 to +55 A1) B) subject to alterations [Pa] [in H2O] Curves 1,25 350 200 0,75 250 1,0 300 150 0,5 2 A 2 100 0,25 B 1 50 100 0 100 1 200 200 300 300 400 500 50 Hz 18 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2600 51 0.25 A 2 2530 53 0.26 B 1 2240 54 0.27 B 2 2120 56 0.28 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: A variable, B axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, B also GOST EC centrifugal, backward Dimensions kg l R2E 175-AR72 -05 0.9 68.5 450.0 09576-2-4013 R2S 175-AB56 -01 0.9 69.0 400.0 09576-2-4013 c ±1 61,5 ±0,5 EC centrifugal, backward for clean rooms c Inlet nozzle (long) Centrifugal fan 14 EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Ø 58 ±0,2 EC-SYSTEMS 90˚ 27,5 Ø 170 Ø125,5 Ø175 Ø72 Ø131 10 20 l 6 Accessories M4 Depth of screw max. 5 mm 2 Technology 42 62 19 Inlet nozzle p. 550 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, Ø 190 Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection M2E 068-BF Power input R2E 190 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 60 570 620 2500 2700 58 75 0.26 0.34 2.0 /400 2.0 /400 62 64 1~ 230 1~ 230 A -25 to +50 -25 to +55 A1) subject to alterations 2 [Pa] [in H O] Curves 1,5 400 1,0 300 A 200 0,5 2 100 1 0 100 100 200 200 300 300 400 500 50 Hz 20 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2490 59 0.26 A 2 2410 61 0.27 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST kg Inlet nozzle (long) R2E 190-AO26 -05 1.2 09576-2-4013 68,5±1 62,7±0,5 14 10 EC centrifugal, forward Ø 58 ±0,2 90˚ EC-SYSTEMS 27 Ø 170 Ø125,5 Ø190 15 Ø92 Ø131 Ø27±0,1 2 0 45 6 M4 Depth of screw max. 5 mm 2 Accessories 44,6 62,8 Technology Brass lead tips 21 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – AC centrifugal fans backward curved, Ø 220 Electr. connection B Perm. amb. temp. M2E 068-CF Sound pressure level R2E 220 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 068-BF Power input R2E 220 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 860 900 885 990 2600 2700 2700 3050 85 90 85 115 0.38 0.40 0.38 0.51 3.0 /400 2.0 /400 2.5 /400 2.5 /400 73 74 72 75 -25 to +40 -25 to +40 -25 to +55 -25 to +55 A1) A1) subject to alterations [Pa] 1,5 400 300 2 1,0 2 200 A 0,5 B 100 1 0 100 200 200 300 400 1 400 600 500 [CFM] 800 [m3/h] 50 Hz 22 60 Hz n [rpm] P1 [W] I [A] A 1 2390 95 0.42 A 2 2490 90 0.40 B 1 2650 96 0.43 B 2 2600 102 0.46 2 2,0 500 [in H O] Curves General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST EC centrifugal, backward Dimensions kg d e R2E 220-AA40 -05 1.3 63.0 15.0 09609-2-4013 R2E 220-AB06 -05 1.5 73.0 25.0 09609-2-4013 71±1 d ±0,5 EC centrifugal, backward for clean rooms Inlet nozzle (long) Centrifugal fan 21 EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Ø 58 ±0,2 22 EC-SYSTEMS 90˚ 27 Ø252 Ø155 Ø220 e Ø 92 Ø159 Ø 27±0,1 2 0 45 6 Accessories M4 Depth of screw max. 5 mm 2 Technology 44 63 23 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, Ø 225 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 850 945 1050 1160 2650 2950 2700 3000 105 145 115 165 0.46 0.64 0.51 0.72 3.0 /450 3.0 /450 3.0 /450 3.0 /450 70 72 72 75 Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R2E 225 M2E 068-DF A R2E 225 M2E 068-DF B 1~ 1~ 1~ 1~ -25 to +60 -25 to +65 -25 to +60 -25 to +30 A1) A1) subject to alterations 2 2,5 [Pa] [in H O] Curves 500 2,0 600 400 1,5 2 300 1,0 2 0,5 200 100 1 1 A 0 200 200 400 400 600 B 600 800 1000 [CFM] 1200 50 Hz 24 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2580 110 0.49 A 2 2560 113 0.50 B 1 2620 135 0.60 B 2 2670 124 0.55 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, B also GOST EC centrifugal, backward Dimensions kg b c g R2E 225-AT51 -05 2.1 63.3 69.0 38.0 96358-2-4013 R2E 225-AX52 -05 2.1 75.3 85.0 50.0 96358-2-4013 c ±1 83 ±0,5 EC centrifugal, backward for clean rooms Inlet nozzle (long) Centrifugal fan 28 EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Ø 58 ±0,2 25 EC-SYSTEMS 90˚ 27 Ø223 Ø146 Ø225 35 Ø 92 Ø153 Ø 27±0,1 2 0 45 6 Depth of screw max. 5 mm 2 Technology b Accessories M4 g 25 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, Ø 225 Electr. connection B Perm. amb. temp. M4E 068-CF Sound pressure level R4E 225 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 068-DF Power input R2E 225 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "F", B "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 1200 1340 655 765 2650 2950 1420 1660 135 200 40 37 0.60 0.88 0.20 0.18 4.0 /450 4.0 /450 1.5 /400 1.0 /400 69 71 59 61 -25 to +60 -25 to +60 -25 to +50 -25 to +80 A1) A1) subject to alterations 2 2,5 [Pa] [in H O] Curves 500 2,0 600 400 1,5 2 A 1,0 300 0,5 200 2 100 1 B 1 0 200 200 400 400 600 600 800 1000 [CFM] 1200 50 Hz 26 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2610 146 0.66 A 2 2650 138 0.61 B 1 1410 41 0.20 B 2 1400 43 0.21 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: A variable, B axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC EC centrifugal, backward Dimensions kg d e R2E 225-BD92 -09 2.1 83.0 35.0 96358-2-4013 R4E 225-AT01 -05 1.8 72.6 25.0 96358-2-4013 99 ±1 d ±0,5 EC centrifugal, backward for clean rooms Inlet nozzle (long) Centrifugal fan 28 EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Ø 58 ±0,2 25 EC-SYSTEMS 90˚ 27 Ø223 Ø146 Ø225 e Ø 92 Ø153 Ø 27±0,1 2 0 45 6 Accessories M4 Depth of screw max. 5 mm 2 Technology 62,6 89,3 27 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, Ø 250 R4E 250 M4E 068-CF C Electr. connection B Perm. amb. temp. M2E 068-DF Sound pressure level R2E 250 1~ 1~ 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 068-EC Power input R2E 250 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "F", B C "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 230 230 50 60 50 60 50 60 1450 1490 1230 1335 810 930 2600 2700 2550 2750 1400 1600 155 215 115 160 43 43 0.70 0.95 0.51 0.71 0.20 0.20 5.0 /400 5.0 /400 4.0 /400 4.0 /400 1.5 /400 1.0 /400 75 76 71 72 61 64 -25 to +70 -25 to +45 -25 to +65 -25 to +45 -25 to +70 -25 to +80 A1) A1) A1) subject to alterations 2 [Pa] [in H O] Curves P1 [W] I [A] A 1 2400 152 0.69 A 2 2400 152 0.69 B 1 2350 137 0.61 B 2 2435 127 0.56 C 1 1385 46 0.21 C 2 1370 47 0.21 2,5 700 n [rpm] 500 2,0 600 400 2 1,5 2 A 1,0 300 B 200 0,5 C 1 1 2 100 1 0 200 200 400 400 600 600 800 1000 [CFM] 1200 50 Hz 28 [m3/h] 60 Hz General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: A B variable, C axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, A C also GOST EC centrifugal, backward Dimensions kg b c d e g k R2E 250-AS47 -26 3.1 84.3 99.0 97.5 42.0 56.0 27.0 96359-2-4013 R2E 250-AV65 -01 2.6 73.3 89.0 83.0 35.0 45.0 27.0 96359-2-4013 R4E 250-AH01 -05 2.2 84.3 99.0 72.6 25.0 56.0 29.0 96359-2-4013 c ±1 d ±0,5 31 EC centrifugal, backward for clean rooms Inlet nozzle (long) Centrifugal fan EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Ø 58 ±0,2 28 EC-SYSTEMS 90˚ k Ø 255 Ø 164,5 Ø 250 e Ø 92 Ø 172 Ø 27±0,1 2 0 45 M4 g 2 Technology b Depth of screw max. 5 mm 29 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips Accessories 6 AC centrifugal fans backward curved, Ø 310 Capacitor Sound pressure level Perm. amb. temp. Electr. connection A Current draw M4E 068-EC Power input R4E 310 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6 Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 60 1830 2070 1400 1600 105 140 0.50 0.62 4.0 /400 4.0 /400 63 66 1~ 230 1~ 230 -25 to +55 -25 to +55 A1) subject to alterations A 2 [Pa] [in H O] Curves 1,0 300 200 0,5 2 100 1 0 250 400 500 800 750 1200 1000 1600 1250 2000 50 Hz 30 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1380 118 0.56 A 2 1360 127 0.60 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Inlet nozzle (long) R4E 310-AT06 -01 3.5 97512-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Depth of screw max. 5 mm 154±1 EC centrifugal, forward 53 58 ±0,2 30 97,5 ±1 M4 27 Ø 300 Ø 192 Ø 92 Ø 203 Ø 318 Ø 27±0,1 42 EC-SYSTEMS 60 Brass lead tips Accessories 6 85 450 ±20 2 Technology 101 132 31 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts 2 AC centrifugal fans backward curved, Ø 330 Capacitor Sound pressure level Perm. amb. temp. Electr. connection A Current draw M4E 074-DF Power input R4E 330 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6 Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 60 1760 2070 1450 1700 95 135 0.44 0.61 4.0 /400 4.0 /400 66 69 1~ 230 1~ 230 -25 to +60 -25 to +40 A1) subject to alterations A 2 [Pa] [in H O] Curves 1,0 300 200 0,5 2 100 1 0 250 400 500 800 750 1200 1000 1600 1250 2000 50 Hz 32 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1420 112 0.52 A 2 1395 128 0.59 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg Inlet nozzle (long) R4E 330-AA06 -05 3.6 51357-2-4013 Depth of screw max. 10 mm 144±1 60 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – 90 ±0,2 5 54 104 ±1 M6 EC-SYSTEMS 37 Ø 350 Ø 224 Ø 75 ±0,1 2 Technology 80 127 33 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips Accessories 85 6 45 0± 20 Ø 102 Ø 237 Ø 360 28 35 AC centrifugal fans backward curved, Ø 355 R6E 355 M6E 074-DF C Electr. connection B Perm. amb. temp. M4E 074 -GA Sound pressure level R4E 355 1~ 1~ 1~ 1~ 1~ 1~ Capacitor A Current draw M4E 074-EI Power input R4E 355 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6 Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 230 230 50 60 50 60 50 60 2365 2740 2740 3190 1875 2050 1410 1630 1400 1630 910 1000 170 250 215 300 65 90 0.78 1.10 1.00 1.32 0.29 0.40 6.0 /400 6.0 /400 7.0 /400 7.0 /400 2.0 /400 2.0 /400 66 70 68 68 61 62 -25 to +55 -25 to +40 -25 to +50 -25 to +30 -25 to +70 -25 to +50 A1) A1) A1) subject to alterations 2 [Pa] [in H O] Curves 1,5 400 A 300 1,0 B 2 2 0,5 200 100 2 1 C 0 500 1000 1 1 1000 [CFM] 1500 2000 3000 50 Hz 34 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1390 190 0.82 A 2 1360 212 0.94 B 1 1390 228 1.06 B 2 1360 259 1.20 C 1 870 73 0.33 C 2 835 77 0.36 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC EC centrifugal, backward Dimensions kg c d e g R4E 355-AF05 -05 4.4 148.5 165.5 117.0 48.0 101.5 51357-2-4013 R4E 355-AG01 -05 4.5 173.0 190.0 129.0 60.0 126.0 51357-2-4013 R6E 355-AB16 -05 4.0 173.0 190.0 104.0 35.0 126.0 51357-2-4013 EC centrifugal, backward for clean rooms b Inlet nozzle (long) Centrifugal fan EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – Depth of screw max. 10 mm c ±1 60 90 ±0,2 d ±1 M6 37 Ø 350 Ø 102 Ø 237 Ø 360 85 6 Accessories 45 0± 20 Ø 75 ±0,1 e Ø 224 28 EC-SYSTEMS 5 54 2 g Technology b 35 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, Ø 250 Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection M2E 068-EC Power input R2E 250 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet steel, coated in black Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 1780 2650 185 0.81 6.0 /400 72 1~ 230 A -25 to +50 A1) subject to alterations 1,5 400 2 A 1,0 300 200 0,5 1 100 0 250 400 500 800 750 1200 1000 1600 50 Hz 36 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2510 220 0.97 A 2 2615 190 0.84 2 [Pa] [in H O] Curves General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg Inlet nozzle (long) R2E 250-AW50 -05 3.1 96359-2-4013 141±1 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – 58 ±0,2 31 97,5 ±0,5 28 Ø EC-SYSTEMS 90˚ 27 Ø 255 Ø164,5 ±2 Ø 250 Ø 92 0 0 45 Ø172 42 Ø 27±0,1 Ø 222 2 6 60 2 M4 92 Technology Depth of screw max. 5 mm 37 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips Accessories 85 AC centrifugal fans backward curved, Ø 270 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 60 2435 2760 2750 3100 280 430 1.23 1.88 10.0 /400 10.0 /400 77 80 Curve Nominal voltage – Material: Impeller: Sheet steel Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R2E 270 M2E 074-GA 1~ 230 1~ 230 A -25 to +60 -25 to +60 A1) subject to alterations 2 [Pa] [in H O] Curves 2,5 700 500 2,0 600 A 400 1,5 2 1,0 300 200 0,5 1 100 0 250 500 600 750 1200 1000 1800 1250 1500 2400 50 Hz 38 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2665 245 1.08 A 2 2690 332 1.47 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Capacitor: FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: CCC kg Inlet nozzle (long) R2E 270-AA01 -05 4.7 96360-2-4013 171±1 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – – 90 ±0,2 35 129 ±0,5 31 Ø EC-SYSTEMS 90˚ 37 Ø 280 Ø182,5 ±2 Ø 270 0 0 45 Ø191 Ø 102 60 Ø 75 ±0,1 Ø 240 5 6 70 2 M6 102 Technology Depth of screw max. 10 mm 39 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips Accessories 85 AC centrifugal fans backward curved, Ø 280 Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection M2D 074-EI Power input R2D 280 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet steel, galvanised Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 50 50 1790 1460 2730 2200 210 160 0.37 0.25 3~ 400 ∆ 3~ 400 Y A B — — 79 75 -25 to +80 -25 to +70 F1a)/F2a) subject to alterations 2 [Pa] [in H O] Curves 2,5 700 500 2,0 600 400 1,5 2 A 300 1,0 2 B 200 1 0,5 1 100 0 250 400 500 800 [CFM] 750 1200 1600 50 Hz 40 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2650 252 0.44 A 2 2550 302 0.53 B 1 1960 187 0.30 B 2 1975 185 0.29 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE kg Inlet nozzle (long) R2D 280-AF10 -09 4.6 96360-2-4013 Depth of screw max. 10 mm 125 ±1 35 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – 90 ±0,2 5 M6 117 ±1 EC-SYSTEMS 37 Ø280 Ø182,5 Ø90 ±0,1 2 Technology 50 81,6 41 Inlet nozzle p. 550 Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips Accessories 85 6 45 0± 20 Ø102 Ø191 Ø281 31 48 AC centrifugal fans backward curved, Ø 280 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 1~ 230 50 2110 2700 225 1.00 7.0 /400 76 -25 to +40 1~ 230 1~ 230 50 60 1435 1685 1420 1635 78 105 0.35 0.42 2.5 /450 2.5 /450 62 67 -25 to +40 -25 to +40 Curve Nominal voltage – Material: Impeller: Sheet steel, coated in black Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "F", B "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R2E 280 M2E 068-EC R4E 280 M4E 068-DF A B A1) A1) subject to alterations 2 [Pa] [in H O] Curves 2,5 700 500 2,0 600 400 1,5 2 A 1,0 300 B 200 1 0,5 2 100 1 0 250 400 42 500 800 750 1200 1000 1600 1250 [CFM] 2000 [m3/h] 50 Hz 60 Hz n [rpm] P1 [W] I [A] A 1 2560 265 1.18 A 2 2390 312 1.38 B 1 1380 88 0.40 B 2 1340 99 0.44 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: A variable, B axial Protection class: I Capacitor: A FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST EC centrifugal, backward Dimensions kg b d e g R2E 280-AE52 -05 3.0 81.6 97.5 42.0 50.0 96360-2-4013 R4E 280-AD08 -05 2.8 111.4 82.5 35.0 80.0 96360-2-4013 125 ±1 d ±0,5 EC centrifugal, backward for clean rooms Inlet nozzle (long) Centrifugal fan 35 EC centrifugal, forward Mass of centrifugal fan AC centrifugal, forward – – – – – – Ø 58 ±0,2 31 EC-SYSTEMS 90˚ 27 Ø 280 Ø 182,5 Ø 92 Ø 191 e Ø 280 Ø 27±0,1 2 0 45 6 Depth of screw max. 5 mm 2 Technology b Accessories M4 g 43 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Brass lead tips AC centrifugal fans backward curved, 3-D, Ø 310 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230/400 230/400 230/400 230/400 50 60 50 60 1710 1990 2120 2450 1430 1650 1400 1600 85 115 110 150 0.52/0.30 0.45/0.26 0.55/0.32 0.52/0.30 Curve Nominal voltage – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 310 (1) M4D 068-EC A R4D 310 (1) M4D 068-EC B subject to alterations 3~ 3~ 3~ 3~ — — — — 62 66 60 63 2 [Pa] [in H O] 1,5 400 350 1,0 300 200 2 2 0,5 150 1 100 1 A 50 0 250 400 500 800 750 1200 B 1000 1600 1250 2000 [CFM] [m3/h] 50 Hz 44 C1)/C2) C1)/C2) (1) 230 VAC ∆ / 400 VAC Y Curves (established with long inlet nozzle) 250 -25 to +75 -25 to +80 -25 to +65 -25 to +55 60 Hz n [rpm] P1 [W] I [A] A 1 1400 107 0.65/0.38 A 2 1400 113 0.69/0.40 B 1 1360 136 0.69/0.40 B 2 1350 141 0.71/0.41 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC EC centrifugal, backward Mass of centrifugal fan AC centrifugal, forward – – – – – Inlet nozzle (long) Inlet nozzle (short) 70.0 31050-2-4013 31051-2-4013 139.0 154.0 101.0 31050-2-4013 31051-2-4013 Centrifugal fan kg b c R4D 310-AR18 -01 3.3 104.0 123.0 R4D 310-AS18 -01 3.4 g EC centrifugal, backward for clean rooms Dimensions c ±1 EC centrifugal, forward Inlet nozzle (long) 48 Ø 58 ± 0,2 2 18 97,5 ±0,5 EC-SYSTEMS 90˚ 27 Ø300 Ø208,1 Ø211 Ø92 Ø220 Ø318 Ø27± 0,1 55,5 42 6 450 Accessories Brass lead tips M4 2 g Depth of screw max. 5 mm 45 Inlet nozzle p. 550 Guard grille p. 553 Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology b AC centrifugal fans backward curved, 3-D, Ø 310 Electr. connection B Perm. amb. temp. M4E 068-EC Sound pressure level R4E 310 1~ 1~ 1~ 1~ Capacitor A Current draw M4E 068-EC Power input R4E 310 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "B", B "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 1690 1950 2130 2380 1410 1650 1370 1530 95 125 120 160 0.46 0.56 0.54 0.71 4.0 /400 4.0 /400 4.0 /400 4.0 /400 62 66 59 62 -25 to +70 -25 to +65 -25 to +85 -25 to +50 A1) A1) subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 1,5 400 350 250 1,0 300 2 2 200 A 0,5 150 1 100 1 B 50 0 250 400 500 800 750 1200 1000 1600 1250 2000 50 Hz 46 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1370 114 0.55 A 2 1360 118 0.57 B 1 1310 140 0.63 B 2 1320 140 0.63 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC EC centrifugal, backward Mass of centrifugal fan AC centrifugal, forward – – – – – Inlet nozzle (long) Inlet nozzle (short) 70.0 31050-2-4013 31051-2-4013 139.0 154.0 101.0 31050-2-4013 31051-2-4013 Centrifugal fan kg b c R4E 310-AR06 -01 3.3 104.0 123.0 R4E 310-AS06 -01 3.4 g EC centrifugal, backward for clean rooms Dimensions c ±1 EC centrifugal, forward Inlet nozzle (long) 48 Ø 58 ± 0,2 2 18 97,5 ±0,5 EC-SYSTEMS 90˚ 27 Ø300 Ø208,1 Ø211 Ø92 Ø220 Ø318 Ø27± 0,1 55,5 42 6 450 Accessories Brass lead tips M4 2 g Depth of screw max. 5 mm 47 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology b AC centrifugal fans backward curved, 3-D, Ø 310 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 1110 1320 1400 1640 950 1120 920 1070 45 55 48 60 0.21 0.25 0.22 0.27 1.5 /450 1.5 /450 1.5 /450 1.5 /450 51 55 50 53 Curve Nominal voltage – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6E 310 M6E 068-EC A R6E 310 M6E 068-EC B 1~ 1~ 1~ 1~ -25 to +75 -25 to +80 -25 to +75 -25 to +75 A1) A1) subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 0,5 150 2 2 0,25 100 1 50 1 A 0 250 200 400 500 600 800 B 750 1000 1200 [CFM] 1400 50 Hz 48 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 950 46 0.21 A 2 925 50 0.23 B 1 885 53 0.24 B 2 900 51 0.23 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC EC centrifugal, backward Mass of centrifugal fan AC centrifugal, forward – – – – – Inlet nozzle (long) Inlet nozzle (short) 70.0 31050-2-4013 31051-2-4013 139.0 154.0 101.0 31050-2-4013 31051-2-4013 Centrifugal fan kg b c R6E 310-AI04 -01 3.3 104.0 123.0 R6E 310-AJ04 -01 3.4 g EC centrifugal, backward for clean rooms Dimensions c ±1 EC centrifugal, forward Inlet nozzle (long) 48 Ø 58 ± 0,2 2 18 97,5 ±0,5 EC-SYSTEMS 90˚ 27 Ø300 Ø208,1 Ø211 Ø92 Ø220 Ø318 Ø27± 0,1 55,5 42 6 450 Accessories Brass lead tips M4 2 g Depth of screw max. 5 mm 49 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology b AC centrifugal fans backward curved, 3-D, Ø 355 R4E 355 M4E 074-GA C Electr. connection B Perm. amb. temp. M4E 074-EI Sound pressure level R4E 355 3~ 3~ 1~ 1~ 1~ Capacitor A Current draw M4D 074-EI Power input R4D 355 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 400 Y 400 Y 230 230 230 50 60 50 60 50 2580 2930 2580 2940 3160 1400 1600 1400 1600 1420 170 235 180 260 245 0.52 0.50 0.80 1.14 1.12 — — 6.0 /450 6.0 /450 8.0 /400 65 69 66 69 66 -25 to +70 -25 to +65 -25 to +60 -25 to +35 -25 to +50 D2) A1) A1) subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 500 1,5 1,0 2 2 C 200 0,5 B A 1 100 0 500 500 1000 1000 1500 1 1500 2000 2500 [CFM] 3000 50 Hz 50 [m3/h] 60 Hz P1 [W] I [A] A 1 1375 205 0.63 A 2 1360 227 0.70 B 1 1350 209 0.93 B 2 1330 229 1.02 C 1 1395 273 1.25 C 2 1375 295 1.35 400 300 n [rpm] General information B C TOP wired internally AC centrifugal, backward Motor protection: A design with thermal overload protector, Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg R4D 355-AH11 -05 4.7 R4E 355-AK05 -05 R4E 355-AL02 -05 Dimensions b c d Inlet nozzle (long) Inlet nozzle (short) 96.0 35560-2-4013 35561-2-4013 96.0 35560-2-4013 35561-2-4013 60.0 120.5 35560-2-4013 35561-2-4013 e g 146.5 167.0 117.0 48.0 4.7 146.5 167.0 117.0 48.0 5.3 171.0 190.0 129.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal fan AC centrifugal, forward – – – – – 60 22 ,5 37 Ø 240 Ø 236,4 Ø360 Ø250 Ø 102 Ø75 ±0,1 ±2 0 85 6 Accessories 45 0 90 ±0,2 M6 70 e Ø 350 d ±1 44 5 Depth of screw max. 10 mm EC-SYSTEMS c ±1 EC centrifugal, forward Inlet nozzle (long) 2 Brass lead tips g 51 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology b AC centrifugal fans backward curved, 3-D, Ø 355 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 230 230 230 230 50 60 50 60 1700 1890 1930 1940 910 1000 870 890 65 85 70 90 0.29 0.37 0.31 0.40 2.0 /400 2.0 /400 2.0 /400 2.0 /400 54 57 52 53 Curve Nominal voltage – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6E 355 M6E 074-DF A R6E 355 M6E 074-DF B 1~ 1~ 1~ 1~ -25 to +90 -25 to +75 -25 to +85 -25 to +60 A1) A1) subject to alterations [Pa] 0,6 160 A 0,4 120 2 80 2 0,2 B 1 1 40 0 250 400 500 800 750 1200 1000 1600 50 Hz 52 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 860 71 0.32 A 2 850 73 0.33 B 1 785 80 0.35 B 2 805 78 0.34 2 0,8 200 [in H O] Curves (established with long inlet nozzle) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: GOST EC centrifugal, backward Mass of centrifugal fan AC centrifugal, forward – – – – – Inlet nozzle (long) Inlet nozzle (short) 96.0 35560-2-4013 35561-2-4013 171.0 190.0 120.5 35560-2-4013 35561-2-4013 Centrifugal fan kg b c R6E 355-AD16 -05 3.5 146.5 167.0 R6E 355-AE16 -05 4.1 g EC centrifugal, backward for clean rooms Dimensions 60 22 37 Ø 350 Ø 240 Ø 236,4 Ø360 Ø250 Ø 102 Ø75 ±0,1 ±2 0 Accessories 85 6 45 0 70 35 90 ±0,2 M6 ,5 104 ±1 44 5 Depth of screw max. 10 mm EC-SYSTEMS c ±1 EC centrifugal, forward Inlet nozzle (long) 2 Brass lead tips g 53 Inlet nozzle p. 550 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology b AC centrifugal fans backward curved, 3-D, Ø 400 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) °C p. 596 f. 1~ 230 50 3150 1300 270 1.20 8.0 /400 68 -25 to +45 1~ 230 1~ 230 50 60 2225 2455 910 1000 117 160 0.52 0.70 3.0 /450 3.0 /450 62 64 -25 to +55 -25 to +40 Curve Nominal voltage – Material: Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "F", B "B" – Mounting position: A any, B shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: A none, B rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4E 400 M4E 074-EI R6E 400 A M6E 074-EI B A1) A1) subject to alterations 2 [Pa] [in H O] Curves 1,5 400 300 1,0 2 A 200 B 0,5 2 100 1 1 0 500 500 1000 1000 1500 1500 2000 2500 [CFM] 3000 50 Hz 54 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1240 292 1.30 A 2 1250 287 1.27 B 1 880 125 0.56 B 2 880 125 0.56 General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, B also GOST kg Inlet nozzle (long) R4E 400-AB23 -05 5.2 54476-2-4013 R6E 400-AA04 -05 5.2 54476-2-4013 66 22 117 ±1 37 Ø 370 Ø 257 Ø404 Ø268 Ø 102 ±2 0 Accessories 85 6 45 0 Ø75 ±0,1 48 90 ±0,2 M6 50 90 5 Depth of screw max. 10 mm EC-SYSTEMS 162 ±1 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – 2 Brass lead tips 91 55 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Technology 142 AC centrifugal fans backward curved, 3-D, Ø 400 M4E 094-HA B subject to alterations Electr. connection R4E 400 1~ 1~ 1~ 1~ Perm. amb. temp. A Capacitor M4E 094-FA Max. current draw (1) R4E 400 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB °C p. 596 f. 230 230 230 230 50 60 50 60 1355 1480 1370 1460 375 540 480 700 1.75 2.40 2.40 3.15 8.0 /400 8.0 /400 10.0 /450 10.0 /450 -40 to +60 -40 to +50 -40 to +80 -40 to +55 2 [Pa] [in H O] 2,5 2,0 600 400 2 1,5 2 1,0 300 200 1 1 0,5 B A 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 56 A2a) (1) Nominal data in operating point with maximum load Curves 500 A2a) [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1350 370 1.75 64 A 2 1380 331 1.58 65 B 1 1370 469 2.37 66 B 2 1390 430 2.17 68 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE kg R4E 400-AR05 -06 7.1 R4E 400-AP17 -06 8.8 b c EC centrifugal, backward d Inlet nozzle (long) e g 141.0 172.0 128.0 50.0 90.0 54476-2-4013 164.0 193.0 148.0 70.0 113.0 54476-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Dimensions EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 55 4x90˚ 0 10 57 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, Ø 400 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB °C p. 596 f. 400 ∆ 400 Y 400 ∆ 400 Y 50 50 60 60 1415 1235 1610 1220 515 385 750 515 1.41 0.70 1.44 0.93 Curve Nominal voltage – Material: Impeller: Sheet aluminium, riveted Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 400 M4D 094-HA A B C D subject to alterations 3~ 3~ 3~ 3~ — — — — -40 to +60 -40 to +80 -40 to +60 -40 to +40 (1) Nominal data in operating point with maximum load 2 [Pa] [in H O] Curves 2,0 600 500 1,5 400 C 2 2 300 A 1,0 B D 200 1 0,5 1 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 58 F1a)/F2a) [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1415 490 1.40 63 A 2 1415 500 1.41 65 B 1 1240 380 0.67 70 B 2 1320 281 0.52 66 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE kg Inlet nozzle (long) R4D 400-AD22 -06 8.7 54476-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 55 4x90˚ 0 10 59 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, Ø 400 M6E 094-FA B subject to alterations Electr. connection R6E 400 1~ 1~ 1~ 1~ Perm. amb. temp. A Capacitor M4E 094-HA Max. current draw (1) R4E 400 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, riveted Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB °C p. 596 f. 230 230 230 230 50 60 50 60 1370 1500 895 990 480 695 155 220 2.40 3.18 0.68 0.97 10.0 /400 10.0 /450 5.0 /450 5.0 /450 -40 to +70 -40 to +55 -40 to +95 -40 to +85 2 [Pa] [in H O] 2,0 600 A 1,5 400 2 1,0 300 B 200 1 0,5 2 100 1 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 60 A2a) (1) Nominal data in operating point with maximum load Curves 500 A2a) [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1380 464 2.36 68 A 2 1380 462 2.36 65 B 1 900 149 0.65 56 B 2 910 143 0.65 54 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE EC centrifugal, backward Dimensions Inlet nozzle (long) kg d e R4E 400-AN09 -06 8.7 148.0 70.0 54476-2-4013 R6E 400-AK06 -06 8.7 128.0 50.0 54476-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 55 4x90˚ 0 10 61 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 450 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 1350 0.74 2.60/1.50 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 450 (2) M4D 110-GF subject to alterations A (1) Nominal data in operating point with maximum load — -40 to +80 (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] 400 2 1,5 6 9 300 1,0 12 8 1 0,5 11 4 100 7 10 0 1000 1000 2000 2000 80/140 V 62 3000 100/180 V 3000 4000 130/230 V 5000 [CFM] [m3/h] 230/400 V P1 [kW] I [A] LwA [dB(A)] 1 1370 0.65 2.35/1.35 75 A 2 1350 0.73 2.50/1.45 70 A 3 1380 0.61 2.25/1.30 76 A 4 1155 0.47 2.40/1.40 70 A 5 1115 0.51 2.60/1.50 65 A 6 1180 0.45 2.25/1.30 72 A 7 1055 0.37 2.45/1.40 68 A 8 955 0.38 2.60/1.50 61 A 9 1100 0.32 2.25/1.30 70 A 10 830 0.26 2.25/1.30 61 A 11 780 0.27 2.25/1.30 56 A 12 850 0.25 2.15/1.25 63 5 200 n [rpm] A 3 2,0 500 [in H O] Curves A D1)/D2) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4D 450-AK01 -01 12.5 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63045-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 63 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 450 subject to alterations Capacitor Perm. amb. temp. Electr. connection M4E 110-GF Max. current draw (1) R4E 450 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A µF/VDB °C p. 596 f. 50 1250 0.68 3.00 1~ 230 A 14.0 /400 -40 to +70 (1) Nominal data in operating point with maximum load 2 A 2,0 [Pa] [in H O] Curves 500 3 1,5 400 2 1,0 200 9 5 0,5 1 12 8 100 4 11 7 10 0 1000 1000 2000 2000 3000 105 V 3000 4000 130 V 5000 160 V [CFM] [m3/h] 230 V n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1300 0.65 2.80 74 A 2 1265 0.68 3.00 69 A 3 1320 0.62 2.68 75 A 4 970 0.43 2.80 65 A 5 900 0.43 2.90 60 A 6 1040 0.41 2.71 69 A 7 720 0.29 2.40 61 A 8 670 0.29 2.49 53 A 9 790 0.29 2.41 62 A 10 545 0.19 2.00 50 A 11 510 0.19 2.00 47 A 12 580 0.19 2.00 54 6 300 64 A2a) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4E 450-AK01 -01 12.5 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63045-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 65 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 450 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 930 0.29 1.30/0.75 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 450 (2) M6D 110-EF subject to alterations A (1) Nominal data in operating point with maximum load — -40 to +85 (2) 230 VAC ∆ / 400 VAC Y [Pa] 2 1,0 250 [in H O] Curves A 3 0,75 200 6 2 150 0,5 100 12 8 1 0,25 11 4 7 50 10 0 500 1000 1000 80/140 V 66 1500 2000 2000 3000 100/180 V 2500 4000 130/230 V [CFM] [m3/h] 230/400 V n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 950 0.25 1.12/0.65 66 A 2 940 0.28 1.15/0.66 63 A 3 950 0.26 1.12/0.65 65 A 4 830 0.18 0.92/0.53 61 A 5 805 0.20 1.00/0.58 58 A 6 825 0.18 0.94/0.54 60 A 7 735 0.15 0.94/0.54 58 A 8 705 0.16 1.01/0.58 54 A 9 730 0.15 0.95/0.55 58 A 10 615 0.11 0.90/0.52 52 A 11 580 0.11 0.94/0.54 48 A 12 610 0.11 0.90/0.52 52 9 5 D1)/D2) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6D 450-AN01 -01 10.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63045-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 67 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 450 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 50 930 0.30 1.42 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6E 450 M6E 110-EF 1~ 230 A subject to alterations 8.0 /450 -40 to +70 (1) Nominal data in operating point with maximum load 2 A 1,0 [Pa] [in H O] Curves 250 3 6 200 0,75 2 9 n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 945 0.27 1.30 65 A 2 935 0.29 1.38 61 A 3 945 0.27 1.28 67 A 4 865 0.21 1.30 62 A 5 840 0.22 1.40 59 A 6 880 0.19 1.20 64 A 7 740 0.17 1.41 58 A 8 665 0.18 1.50 53 A 9 775 0.16 1.39 61 A 10 520 0.12 1.30 48 A 11 465 0.12 1.38 44 A 12 565 0.12 1.30 52 5 0,5 150 8 12 100 1 0,25 4 11 50 7 10 0 500 1000 1000 1500 2000 105 V 68 A2a) 2000 3000 130 V 2500 4000 160 V [CFM] [m3/h] 230 V General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6E 450-AN01 -01 10.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63045-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 69 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, Ø 450 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB °C p. 596 f. 3~ 400 ∆ 3~ 400 Y 1~ 230 50 50 50 1380 1130 1290 665 470 640 1.55 0.82 3.10 — -40 to +50 — -40 to +55 10.0 /400 -40 to +50 1~ 230 1~ 230 50 60 905 1010 320 425 1.56 1.86 10.0 /400 -40 to +40 10.0 /450 -40 to +55 Curve Nominal voltage – Material: Impeller: Sheet aluminium, riveted Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 450 M4D 094-HA R4E 450 M4E 094-HA R6E 450 A B C M6E 094-HA D subject to alterations 2 [in H O] 2,0 [Pa] A2a) A2a) (1) Nominal data in operating point with maximum load Curves 500 F1a)/F2a) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1390 610 1.52 70 A 2 1380 650 1.53 69 B 1 1130 470 0.82 64 B 2 1260 350 0.65 68 C 1 1310 602 2.97 69 C 2 1310 596 2.92 68 D 1 910 305 1.50 61 D 2 905 310 1.53 58 A C 2 2 2 1,5 400 B 300 1,0 D 1 2 1 1 0,5 200 1 100 0 500 1000 70 1000 1500 2000 2000 3000 2500 4000 [CFM] [m3/h] General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE EC centrifugal, backward Dimensions kg c g R4D 450-AD22 -06 9.3 175.0 204.0 120.0 54478-2-4013 R4E 450-AB09 -06 9.3 175.0 204.0 120.0 54478-2-4013 R6E 450-AB06 -06 9.6 215.0 244.0 160.0 54478-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward b Inlet nozzle (long) Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 55 4x90˚ 0 10 71 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 500 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 1375 1.43 5.20/3.00 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 500(2) M4D 138-HF A subject to alterations (1) Nominal data in operating point with maximum load — -40 to +80 (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves A 2,5 700 600 2,0 2 1,5 400 6 300 5 1 1,0 9 8 200 4 0,5 12 7 11 100 10 0 1000 1000 2000 2000 3000 80/140 V 72 3000 4000 5000 100/180 V 4000 6000 7000 130/230 V [CFM] [m3/h] 230/400 V n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1380 1.36 4.99/2.88 81 A 2 1375 1.42 5.13/2.96 79 A 3 1375 1.43 5.20/3.00 77 A 4 1150 0.97 5.25/3.03 76 A 5 1125 1.00 5.42/3.13 74 A 6 1140 0.97 5.28/3.05 73 A 7 970 0.73 5.18/2.99 71 A 8 945 0.74 5.30/3.06 69 A 9 970 0.73 5.16/2.98 68 A 10 775 0.49 4.66/2.69 64 A 11 755 0.49 4.73/2.73 63 A 12 775 0.49 4.68/2.70 62 3 500 D1)/D2) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4D 500-AT03 -01 26.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63072-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 18 mm 73 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts Technology Brass lead tips AC centrifugal fans backward curved, 3-D, Ø 500 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 910 0.48 1.90/1.10 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 500(2) M6D 110-GF A subject to alterations (1) Nominal data in operating point with maximum load — -40 to +80 (2) 230 VAC ∆ / 400 VAC Y [Pa] 2 1,0 250 [in H O] Curves A 3 2 0,75 200 5 9 0,5 1 8 100 12 4 11 0,25 7 50 10 0 1000 1000 2000 2000 80/140 V 74 3000 100/180 V 3000 4000 130/230 V 5000 [CFM] [m3/h] 230/400 V n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 915 0.45 1.73/1.00 68 A 2 910 0.47 1.77/1.02 65 A 3 915 0.44 1.69/0.98 66 A 4 760 0.31 1.66/0.96 62 A 5 745 0.32 1.72/1.00 60 A 6 770 0.30 1.60/0.93 61 A 7 650 0.23 1.59/0.92 57 A 8 630 0.24 1.64/0.95 55 A 9 665 0.23 1.57/0.90 57 A 10 530 0.16 1.43/0.82 52 A 11 510 0.16 1.45/0.84 49 A 12 545 0.16 1.41/0.81 52 6 150 D1)/D2) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6D 500-AK03 -01 13.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63072-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 75 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 500 subject to alterations Perm. amb. temp. Electr. connection A Capacitor M6E 110-GF Max. current draw (1) R6E 500 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A µF/VDB °C p. 596 f. 50 910 0.51 2.34 1~ 230 12.0 /450 -40 to +60 (1) Nominal data in operating point with maximum load 2 [Pa] [in H O] Curves A 300 3 1,00 250 0,75 2 200 0,50 100 4 0,25 9 8 7 12 11 10 0 1000 2000 2000 105 V 76 3000 4000 4000 6000 130 V 160 V [CFM] [m3/h] 230 V P1 [kW] I [A] LwA [dB(A)] 1 915 0.49 2.24 70 A 2 910 0.51 2.33 67 A 3 915 0.48 2.22 68 A 4 720 0.37 2.55 62 A 5 690 0.38 2.64 60 A 6 730 0.37 2.50 61 A 7 515 0.27 2.35 52 A 8 485 0.27 2.37 49 A 9 510 0.27 2.34 52 A 10 370 0.17 1.94 46 A 11 355 0.17 1.94 44 A 12 375 0.17 1.94 45 1 5 n [rpm] A 6 150 50 A2a) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6E 500-AK01 -01 13.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63072-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 77 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, Ø 500 subject to alterations Capacitor Perm. amb. temp. Electr. connection M6E 094-HA Max. current draw (1) R6E 500 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, riveted Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB °C p. 596 f. 50 60 820 850 385 475 1.82 2.10 1~ 230 1~ 230 A 10.0 /400 -40 to +40 10.0 /450 -40 to +40 (1) Nominal data in operating point with maximum load 2 1,25 [Pa] [in H O] Curves 1,00 300 0,75 2 0,50 200 1 0,25 100 A 0 1000 1000 78 A2a) 2000 2000 3000 3000 4000 [CFM] 5000 [m3/h] 50 Hz 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 845 360 1.72 62 A 2 830 376 1.79 57 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – R6E 500-AB05 -06 11.1 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 54480-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 55 4x90˚ 0 10 79 Inlet nozzle p. 550 Guard grille p. 553 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 560 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 1365 2.38 8.66/5.00 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 560 (2) M4D 138-LA A subject to alterations (1) Nominal data in operating point with maximum load — -40 to +60 (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves A 3,0 800 2,5 700 3 500 2,0 600 2 6 1,5 400 300 5 1,0 9 1 200 8 4 0,5 12 100 10 0 2000 4000 3000 6000 80/140 V 80 7 11 6000 9000 100/180 V [CFM] 12000 130/230 V [m3/h] 230/400 V D1)/D2) n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1380 2.14 8.33/4.81 84 A 2 1370 2.33 8.66/5.00 82 A 3 1365 2.34 8.66/5.00 81 A 4 1140 1.53 8.31/4.80 77 A 5 1110 1.62 8.75/5.05 76 A 6 1105 1.62 8.73/5.04 75 A 7 955 1.13 8.11/4.68 74 A 8 920 1.17 8.42/4.86 73 A 9 915 1.17 8.38/4.84 71 A 10 765 0.77 7.31/4.22 70 A 11 735 0.78 7.45/4.30 67 A 12 730 0.78 7.47/4.31 65 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4D 560-AQ03 -01 28.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63071-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 18 mm 81 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts Technology Brass lead tips AC centrifugal fans backward curved, 3-D, Ø 560 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 885 0.78 2.95/1.70 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 560 (2) M6D 110-IA A subject to alterations (1) Nominal data in operating point with maximum load — -40 to +55 (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves A 1,25 350 300 250 1,0 3 200 0,75 2 150 6 0,5 1 9 5 100 8 0,25 12 4 7 11 50 10 0 1000 1000 2000 2000 3000 80/140 V 82 3000 4000 5000 100/180 V 4000 6000 7000 130/230 V [CFM] 8000 [m3/h] 230/400 V D1)/D2) n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 905 0.68 2.71/1.56 71 A 2 890 0.76 2.87/1.65 69 A 3 890 0.76 2.85/1.64 69 A 4 665 0.48 2.85/1.64 68 A 5 610 0.49 2.89/1.67 58 A 6 605 0.49 2.88/1.66 59 A 7 595 0.32 2.31/1.34 65 A 8 560 0.33 2.40/1.39 58 A 9 565 0.33 2.39/1.38 57 A 10 480 0.21 1.99/1.15 54 A 11 450 0.21 2.03/1.17 50 A 12 450 0.18 2.03/1.17 50 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6D 560-AH05 -01 15.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63071-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 12 mm Brass lead tips Mounting dimensions Ø Technology Ø7 5 Ø 11 Ø 130 4x90˚ 0 10 83 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts 28 AC centrifugal fans backward curved, 3-D, Ø 630 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 1300 4.25 13.10/7.55 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 630 (2) M4D 138-LA subject to alterations A (1) Nominal data in operating point with maximum load — -40 to +60 (2) 230 VAC ∆ / 400 VAC Y [Pa] 2 4,0 1000 [in H O] Curves A 3 3,0 800 2 2,0 600 6 400 1 5 1,0 9 200 8 12 4 7 11 10 0 2500 5000 4000 80/140 V 84 7500 8000 12000 100/180 V 10000 16000 130/230 V [CFM] [m3/h] 230/400 V D1)/D2) n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1325 3.93 12.33/7.12 84 A 2 1300 4.21 13.01/7.51 82 A 3 1340 3.55 11.19/6.46 86 A 4 960 2.30 12.85/7.42 76 A 5 930 2.36 13.10/7.55 74 A 6 1005 2.19 12.13/7.01 78 A 7 745 1.50 11.32/6.53 70 A 8 725 1.54 11.49/6.63 69 A 9 785 1.46 11.03/6.37 71 A 10 575 0.94 9.47/5.47 63 A 11 550 0.94 9.54/5.51 61 A 12 610 0.93 9.34/5.39 64 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4D 630-AQ03 -01 29.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63070-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 18 mm 85 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts Technology Brass lead tips AC centrifugal fans backward curved, 3-D, Ø 630 subject to alterations Perm. amb. temp. Electr. connection A Capacitor M4D 138-NA Max. current draw (1) R4D 630 (2) Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 1170 3.31 10.74/6.20 (1) Nominal data in operating point with maximum load — -40 to +35 (2) 230 VAC ∆ / 400 VAC Y [Pa] 2 4,0 1000 [in H O] Curves A 3,0 800 3 2,0 600 2 400 6 1 1,0 9 5 200 12 8 11 4 7 10 0 2000 4000 4000 80/140 V 86 6000 8000 100/180 V [CFM] 8000 12000 130/230 V 16000 [m3/h] 230/400 V D1)/D2) n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1170 3.11 10.09/5.83 81 A 2 1145 3.21 10.30/5.95 79 A 3 1200 2.84 9.18/5.30 83 A 4 785 1.42 8.06/4.65 70 A 5 760 1.42 8.09/4.67 68 A 6 830 1.35 7.65/4.41 72 A 7 640 0.93 6.77/3.91 65 A 8 625 0.93 6.78/3.92 63 A 9 685 0.89 6.52/3.76 66 A 10 520 0.59 5.57/3.22 59 A 11 510 0.59 5.56/3.21 58 A 12 550 0.57 5.40/3.12 60 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R4D 630-AW01 -01 31.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63070-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 18 mm 87 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts Technology Brass lead tips AC centrifugal fans backward curved, 3-D, Ø 630 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB °C p. 596 f. 3~ 230/400 50 880 1.31 4.85/2.80 Curve Nominal voltage – Material: Impeller: Sheet aluminium, welded Rotor: Cast in aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 630 (2) M6D 138-HF subject to alterations A (1) Nominal data in operating point with maximum load — -40 to +60 (2) 230 VAC ∆ / 400 VAC Y [Pa] 2 2,0 500 [in H O] Curves A 1,5 400 3 2 1,0 300 1 6 200 5 9 0,5 4 8 100 12 7 11 10 0 2000 2000 4000 80/140 V 88 4000 6000 100/180 V 8000 6000 [CFM] 10000 [m3/h] 130/230 V 230/400 V D1)/D2) n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 885 1.28 4.85/2.80 73 A 2 885 1.30 4.82/2.79 73 A 3 890 1.23 4.65/2.69 73 A 4 675 0.82 4.72/2.72 67 A 5 675 0.82 4.75/2.74 67 A 6 690 0.80 4.59/2.65 67 A 7 540 0.57 4.37/2.52 60 A 8 535 0.56 4.35/2.51 60 A 9 560 0.57 4.27/2.46 61 A 10 420 0.36 3.72/2.15 54 A 11 415 0.36 3.74/2.16 54 A 12 430 0.36 3.70/2.14 54 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – R6D 630-AT03 -01 27.0 Inlet nozzle (long) EC centrifugal, backward for clean rooms kg 63070-2-4013 Accessories EC-SYSTEMS EC centrifugal, forward Centrifugal fan Depth of screw max. 18 mm 89 Inlet nozzle p. 550 Guard grille p. 553 Electr. connections p. 596 f. Contacts Technology Brass lead tips 90 General information Ø 085 - Ø 400 92 AC centrifugal blowers with plastic housing, dual inlet Ø 140 - Ø 160 158 AC centrifugal blowers, dual inlet Ø 097 - Ø 250 178 91 Contacts Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward AC centrifugal fans and blowers, single inlet AC centrifugal, forward AC centrifugal, backward AC centrifugal fans and blowers forward curved AC centrifugal fan and blower single inlet, Ø 085 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection A Current draw M2E 042-CA Power input *2E 085 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 80 95 2350 2800 32 30 0.15 0.14 1.0 /400 1.0 /400 53 57 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 -25 to +60 -25 to +70 subject to alterations 2 [Pa] [in H O] Curves 0,6 160 0,4 120 80 2 0,2 A 40 1 0 10 20 20 30 40 40 60 50 80 50 Hz 92 [CFM] [m3/h] 60 Hz A 1 2430 32 0.15 A 2 2590 30 0.14 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Capacitor: FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Centrifugal blower with flange kg R2E 085-AA01 -05 0.7 G2E 085-AA01 -01 0.9 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – – 68 ±1 57±1 Brass lead tips M4 47±0 20 EC centrifugal, forward Depth of screw max. 4 mm 2 Ø85 Ø67 Ø59 Ø17 ±0,1 ,1 Ø30 6 EC-SYSTEMS 300 ±20 Accessories 60,2 3 84 20˚ 54,5 Technology 116,5 3x1 34,5 68 58 42 M4 80 300 93 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 71,5 117,5 4,5 5,5 76 66 56 Ø65-1 42 AC centrifugal fan and blower single inlet, Ø 097 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M2E 042-CA Power input *2E 097 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 100 110 2050 2300 35 37 0.16 0.17 1.5 /400 1.5 /400 55 58 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +40 -25 to +55 subject to alterations [Pa] 2 0,8 200 [in H O] Curves 0,6 160 0,4 120 2 80 0,2 A 40 1 0 20 20 94 40 40 60 60 80 [CFM] 100 [m3/h] 50 Hz 60 Hz A 1 2120 35 0.16 A 2 2335 33 0.15 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Capacitor: FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Centrifugal blower without flange kg R2E 097-AD01 -05 0.6 G2E 097-HD01 -02 1.1 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – – 41,5 ±1 55,9 ±1 M4 Brass lead tips Depth of screw max. 4 mm EC centrifugal, forward 2 47±0 20 Ø97 Ø79 Ø59 Ø17±0,1 ,1 Ø32 6 EC-SYSTEMS 300 ±20 40 143 75 120˚ 3 56,5˚ Technology Ø80 3 137 75 46 3x 24 1 Accessories 18 1 53 96 6 60 300 95 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 1 AC centrifugal fan and blower single inlet, Ø 108 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection A Current draw M2E 052-BF Power input *2E 108 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 160 160 1850 1850 30 35 0.14 0.16 1.0 /400 1.0 /400 56 56 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 -25 to +85 -25 to +80 subject to alterations 2 [Pa] [in H O] Curves 1,2 320 0,8 240 A 160 0,4 2 80 1 0 20 40 40 60 80 80 120 100 160 50 Hz 96 [CFM] [m3/h] 60 Hz A 1 2070 34 0.16 A 2 2470 31 0.15 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Centrifugal blower with flange kg R2E 108-AG63 -05 0.6 G2E 108-AG63 -01 1.3 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 63 ±1 54 ±1 M4 58 ±0 15 EC centrifugal, forward Brass lead tips Depth of screw max. 5 mm Ø108 Ø84 Ø72 ,1 Ø55 6 EC-SYSTEMS 300 ±20 52 159 79 4 Accessories 8 M4 50 83 66 115 97 76 71 Ø87-1 Technology 168 118 300 97 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Air filter p. 563 Electr. connections p. 596 f. Contacts 82 AC centrifugal fan and blower single inlet, Ø 120 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection A Current draw M2E 068-BF Power input *2E 120 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 255 265 2350 2450 80 100 0.35 0.44 2.0 /450 2.0 /450 61 62 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 -25 to +55 -25 to +60 subject to alterations 2 [Pa] [in H O] Curves 1,5 400 1,0 300 2 200 0,5 A 100 1 0 25 40 50 80 75 120 100 160 125 200 [CFM] 240 50 Hz 98 [m3/h] 60 Hz A 1 2460 77 0.34 A 2 2665 69 0.31 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST Centrifugal fan kg Centrifugal blower with flange kg R2E 120-AR77 -05 1.2 G2E 120-AR77 -01 1.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 83 ±1 63 ±1 Brass lead tips M4 58 ±0 15 EC centrifugal, forward Depth of screw max. 5 mm 2 Ø120 Ø96 Ø92 Ø27±0,1 ,1 Ø55 6 EC-SYSTEMS 450 ±20 62 178 82 4 Accessories 7 M4 50 83 68 115 100 76 86 Ø100 -1 Technology 184 132 450 99 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts 98 AC centrifugal fans and blowers single inlet, Ø 120 Perm. amb. temp. Electr. connection B Min. back pressure M2E 068-BF Sound pressure level *2E 120 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 052-BF Power input *2E 120 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: A "F", B "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 190 185 275 255 2050 2000 2200 2050 57 66 83 100 0.25 0.29 0.37 0.45 1.5 /400 1.5 /400 2.0 /450 2.0 /450 63 63 64 63 0 0 0 0 n [rpm] P1 [W] I [A] -25 to +55 -25 to +55 -25 to +70 -25 to +60 subject to alterations 2 [Pa] [in H O] Curves 1,5 400 1,0 300 B 200 2 A 0,5 2 100 1 0 25 40 50 80 75 120 1 100 160 125 200 150 240 50 Hz 100 [CFM] [m3/h] 60 Hz A 1 2200 54 0.24 A 2 2410 51 0.23 B 1 2335 80 0.36 B 2 2580 72 0.32 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: B CCC Dimensions Centrifugal blower with flange kg A B C D F G I — — — 59.0 — 60.0 94.0 98.0 82.0 77.0 b c Centrifugal blower without flange 1.0 42.0 48.0 G2E 120-TD76 -01 — 1.3 — 1.2 62.0 85.0 — G2E 120-CR21 -01 1.9 110.0 kg R2E 120-BD76 -09 R2E 120-AR21 -05 6.0 99.0 c ±1 Depth of screw max. 5 mm 2 M4 Brass lead tips EC centrifugal, forward 63 ±1 58 ±0 15 Ø55 EC-SYSTEMS Ø120 Ø96 Ø92 Ø27±0,1 ,1 6 450 ±20 b A B Accessories 170,5 87 ˚ 4x90 3 45˚ Technology Ø95 180 101 71 C D 67 G F 110 6 85 I 450 101 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts Centrifugal fan EC centrifugal, backward for clean rooms Dimensions EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan AC centrifugal, forward – – – – – AC centrifugal fan and blower single inlet, Ø 133 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M2E 068-BF Power input *2E 133 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 245 235 2150 2100 88 110 0.39 0.49 2.0 /450 2.0 /450 65 65 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +60 -25 to +50 subject to alterations 2 [Pa] [in H O] Curves 1,5 400 A 1,0 300 2 0,5 200 100 1 0 25 40 50 80 75 120 100 160 125 200 150 240 50 Hz 102 [CFM] [m3/h] 60 Hz A 1 2290 83 0.37 A 2 2530 73 0.33 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg Centrifugal blower with flange kg R2E 133-AN77 -01 1.3 G2E 133-DN77 -01 1.9 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 68,5 ±1 63 ±1 M4 Brass lead tips EC centrifugal, forward Depth of screw max. 5 mm 2 58 ±0 15 Ø55 Ø133 Ø108 Ø92 Ø27±0,1 ,1 EC-SYSTEMS 6 450 ±20 46 170,5 59 Accessories ˚ 4x90 45˚ Technology 140 103 Inlet nozzle p. 552 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts 81 6 85 450 Ø112 180 3 101 71 67 87 AC centrifugal fan and blower single inlet, Ø 140 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M2E 052-CA Power input *2E 140 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 240 225 1350 1300 63 70 0.29 0.31 1.5 /400 1.5 /400 55 53 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +45 -25 to +35 subject to alterations 2 [Pa] [in H O] Curves 1,5 400 A 1,0 300 200 0,5 2 100 1 0 25 40 50 80 75 120 100 160 125 200 150 240 50 Hz 104 [CFM] [m3/h] 60 Hz A 1 1460 62 0.29 A 2 1930 56 0.26 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Centrifugal fan kg Centrifugal blower with flange kg R2E 140-BI52 -05 1.4 G2E 140-DI52 -01 1.9 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – 45 ±1 58,8 ±1 M4 Brass lead tips EC centrifugal, forward Depth of screw max. 5 mm 58 ±0 20 Ø55 Ø140 Ø121.9 Ø92 ,1 6 EC-SYSTEMS 450 ±20 37,4 216 62 Accessories 4x90 137,6 71 ˚ 45˚ 242 3 Ø125,5 67 95 Technology 158 6 85 450 105 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 62 AC centrifugal fan and blower single inlet, Ø 140 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 370 335 1400 1500 105 115 0.46 0.51 2.0 /450 2.0 /450 59 57 0 50 Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *2E 140 M2E 068-BF A 1~ 230 1~ 230 -25 to +40 -25 to +45 subject to alterations 2 [Pa] [in H O] Curves 1,2 320 2 0,8 240 A 160 0,4 1 80 0 40 80 80 120 160 160 240 200 320 50 Hz 106 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1700 98 0.43 A 2 2100 89 0.40 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST Centrifugal fan kg Centrifugal blower with flange kg R2E 140-AE77 -05 1.2 G2E 140-AE77 -01 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 72 ±1 63 ±1 Brass lead tips M4 58 ±0 15 EC centrifugal, forward Depth of screw max. 5 mm 2 Ø55 Ø140 Ø121 Ø92 Ø27±0,1 ,1 6 EC-SYSTEMS 450 ±20 59 227 M4 5 Accessories 6,3 103 92 120 105 130 115 94 158 Technology 248 107 Ø118 -1 450 107 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts 100 AC centrifugal fans and blowers single inlet, Ø 140 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 385 305 485 480 1650 1700 2400 2350 135 145 160 205 0.60 0.64 0.70 0.90 2.0 /400 2.0 /400 4.0 /400 4.0 /400 63 60 72 71 0 100 0 0 Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *2E 140 M2E 068-CF A *2E 140 M2E 068-DF B 1~ 1~ 1~ 1~ -25 to +55 -25 to +40 -25 to +70 -25 to +45 subject to alterations 2 [Pa] [in H O] Curves 500 1,5 400 B 2 1,0 300 2 200 0,5 A 100 1 0 50 100 100 150 200 1 200 300 250 [CFM] 400 [m3/h] 50 Hz 108 60 Hz n [rpm] P1 [W] I [A] A 1 1900 128 0.57 A 2 2200 117 0.52 B 1 2485 148 0.65 B 2 2630 128 0.57 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST Centrifugal fan kg d e Centrifugal blower with flange kg R2E 140-AL40 -05 1.7 73.0 25.0 G2E 140-AL40 -01 3.0 R2E 140-AI28 -05 2.1 83.0 35.0 G2E 140-AI28 -01 3.4 EC centrifugal, backward for clean rooms Dimensions EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan AC centrifugal, forward – – – – – 72 ±1 Depth of screw max. 5 mm 2 Brass lead tips M4 58 ±0 e EC centrifugal, forward d ±1 Ø55 EC-SYSTEMS Ø140 Ø121 Ø92 Ø27±0,1 ,1 6 450 ±20 59 227 M4 Accessories 6,3 103 5 92 120 105 130 115 94 158 Technology 248 107 Ø118 -1 450 109 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts 100 AC centrifugal blowers single inlet, Ø 140 Perm. amb. temp. Electr. connection B Min. back pressure M2E 068-CF Sound pressure level G2E 140 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 068-BF Power input G2E 140 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Heat-resistant plastic Impeller: A heat-resistant plastic, B galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 370 315 445 390 1650 1700 2000 2150 105 115 137 155 0.46 0.51 0.60 0.68 2.0 /400 2.0 /400 3.0 /400 3.0 /400 59 57 65 64 0 50 0 130 -25 to +55 -25 to +40 -25 to +65 -25 to +50 subject to alterations 2 [Pa] [in H O] Curves 500 400 1,5 B A 300 1,0 2 2 200 0,5 1 100 1 0 50 100 100 150 200 200 [CFM] 300 [m3/h] 50 Hz 110 60 Hz n [rpm] P1 [W] I [A] A 1 1910 98 0.43 A 2 2280 86 0.38 B 1 2220 123 0.54 B 2 2470 105 0.46 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST kg G2E 140-NS38 -01 1.6 G2E 140-NL33 -01 1.6 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – EC centrifugal, forward 237 113 111 Ø101 100 95 EC-SYSTEMS 6 450 ±20 5 Accessories Brass lead tips Technology 3 111 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts 22 ±0,3 Ø125,5 248 261 ±1 267 ±1 85 AC centrifugal fan and blower single inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection A Current draw M2E 068-CA Power input *2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 470 380 1550 1750 140 155 0.62 0.68 3.0 /450 3.0 /450 60 58 0 100 1~ 230 1~ 230 -25 to +50 -25 to +40 subject to alterations [Pa] 2 2,0 500 [in H O] Curves A 1,5 400 1,0 300 2 0,5 200 100 1 0 50 100 100 150 200 200 300 250 400 50 Hz 112 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1835 136 0.60 A 2 2070 126 0.56 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST Centrifugal fan kg Centrifugal blower with flange kg R2E 146-AW07 -05 1.4 G2E 146-DW07 -01 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 72±1 68 ±1 Brass lead tips M4 58 ±0 20 EC centrifugal, forward Depth of screw max. 5 mm 2 Ø146 Ø127 Ø92 Ø27 ±0,1 ,1 Ø55 6 EC-SYSTEMS 450 ±20 62 227 M4 5 Accessories 6,3 101 92 120 105 130 115 94 158 Technology 248 107 Ø125,5 -1 450 113 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts 104 AC centrifugal fans and blowers single inlet, Ø 160 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 600 570 410 445 2100 2100 1300 1400 240 280 67 90 1.05 1.23 0.30 0.40 6.0 /400 6.0 /400 2.0 /450 2.0 /450 72 71 65 67 0 50 0 0 Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *2E 160 M2E 068-EC A *4E 160 M4E 068-CF B 1~ 1~ 1~ 1~ -25 to +50 -25 to +40 -25 to +65 -25 to +65 subject to alterations 2,5 700 400 A 2 1,5 500 2,0 600 1,0 300 200 0,5 B 2 100 1 1 0 100 100 200 200 300 300 400 [CFM] 500 [m3/h] 50 Hz 114 60 Hz n [rpm] P1 [W] I [A] A 1 2210 223 0.98 A 2 2525 172 0.76 B 1 1350 63 0.28 B 2 1395 58 0.26 2 [Pa] [in H O] Curves A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: A variable, B lateral Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal fan kg d e Centrifugal blower with flange kg R2E 160-AY47 -01 2.6 91.0 42.0 G2E 160-AY47 -01 3.9 R4E 160-AB01 -01 1.7 72.0 25.0 G4E 160-AB01 -01 2.9 EC centrifugal, backward for clean rooms Dimensions EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan AC centrifugal, forward – – – – – 72±1 Depth of screw max. 5 mm 2 Brass lead tips M4 58 ±0 e EC centrifugal, forward d ±1 Ø55 6 EC-SYSTEMS Ø160 Ø131 Ø92 Ø27 ±0,1 ,1 450 ±20 62 227 M4 Accessories 6,3 103 5 92 120 105 130 115 94 175 Technology 248 107 Ø130 -1 450 115 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts 100 AC centrifugal fan and blower single inlet, Ø 180 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 760 630 575 594 1950 2150 1250 1300 400 415 110 145 1.75 1.82 0.49 0.64 8.0 /400 8.0 /400 3.0 /450 3.0 /450 73 71 65 65 0 250 0 0 Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: A coated in black, B partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor G2E 180 M2E 074-EI A *4E 180 M4E 068-DF B 1~ 1~ 1~ 1~ -25 to +40 -25 to +40 -25 to +55 -25 to +45 subject to alterations [Pa] [in H2O] Curves 3,0 800 A 600 2,0 2 400 1,0 1 B 200 2 1 100 0 100 200 200 300 300 400 500 400 600 700 50 Hz 116 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2290 335 1.47 A 2 2600 255 1.12 B 1 1300 105 0.47 B 2 1385 92 0.41 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg e Centrifugal blower with flange kg — — 48.0 G2E 180-EH03 -01 5.6 R4E 180-AB01 -05 1.7 35.0 G4E 180-AB01 -01 3.7 89 ±1 Depth of screw max. 5 mm 2 M4 Brass lead tips EC centrifugal, forward 82 ±1 58 ±0 e Ø55 EC-SYSTEMS Ø180 Ø149 Ø92 Ø27±0,1 ,1 6 450 ±20 75 261 Accessories 7 M4 5 194 Technology 281 450 123 Motor protruding by 15 mm! Ø150-1 A 120 110 140 120 125 110 86 105 117 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Air filter p. 563 Electr. connections p. 596 f. Contacts Centrifugal fan EC centrifugal, backward for clean rooms Dimensions EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan AC centrifugal, forward – – – – – AC centrifugal fan and blower single inlet, Ø 180 subject to alterations Perm. amb. temp. Electr. connection B Min. back pressure M4D 074-DF Sound pressure level G4D 180 (1)(2) 3~ 3~ 3~ 3~ Capacitor A Current draw M4D 074-DF Power input *4D 180 (2) Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230/400 230/400 230/400 230/400 50 60 50 60 1010 1090 1110 1180 1330 1440 1290 1370 175 240 195 265 0.68/0.39 0.74/0.43 0.69/0.40 0.81/0.47 (1) data collected via exhaust duct (step diffuser, 1 m length) — — — — 2 [Pa] [in H O] 1,25 1,0 250 B 2 0,75 200 150 0,5 2 A 100 0,25 1 50 1 0 200 200 118 400 400 600 800 600 [CFM] 1000 [m3/h] 50 Hz 60 Hz 0 0 0 0 -25 to +60 -25 to +55 -25 to +60 -25 to +45 n [rpm] P1 [W] I [A] (2) 230 VAC ∆ / 400 VAC Y Curves 300 67 69 69 70 A 1 1360 160 0.62/0.36 A 2 1410 120 0.46/0.27 B 1 1360 163 0.58/0.33 B 2 1420 105 0.38/0.22 C1)/C2) C1)/C2) General information AC centrifugal, backward Motor protection: Without thermal protection Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal blower with flange (large) kg EC centrifugal, backward Dimensions Centrifugal fan kg Centrifugal blower with flange (small) R4D 180-AF20 -05 3.2 G4D 180-FF20 -01 — 6.4 188.0 168.0 134.0 — — — G4D 180-GF20 -01 6.4 278.0 258.0 224.0 180.0 C D E S EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 90.0 120,5 ±1 90 ±0,2 Depth of screw max. 10 mm EC centrifugal, forward 104 ±1 5 37 Ø180 Ø149 Ø102 35 6 EC-SYSTEMS 60 0± 20 Ø75 ±0,1 M6 92 Brass lead tips 183 129 296 90 Accessories 7 163 133 E ˚ 60 5˚ Technology 332 6x Ø149 -1 192 136 600 3,2 155 119 Inlet nozzle p. 552 Guard grille p. 554 Terminal box p. 562 Electr. connections p. 596 f. Contacts Hole with large flange only C D S B AC centrifugal fan and blower single inlet, Ø 180 subject to alterations Perm. amb. temp. Electr. connection B Min. back pressure M4E 074-DF Sound pressure level G4E 180 (1) 1~ 1~ 1~ 1~ Capacitor A Current draw M4E 074-DF Power input *4E 180 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 965 935 1030 910 1220 1200 1130 1170 160 197 180 200 0.71 0.87 0.80 0.88 4.0 /400 4.0 /400 4.0 /400 4.0 /400 66 65 66 64 0 0 0 50 (1) data collected via exhaust duct (step diffuser, length 1 m) 2 [Pa] [in H O] Curves 1,0 300 250 0,75 B 200 150 2 0,5 2 A 0,25 100 50 1 0 200 200 400 400 600 1 [CFM] 800 [m3/h] 50 Hz 120 -25 to +60 -25 to +40 -25 to +45 -25 to +35 60 Hz n [rpm] P1 [W] I [A] A 1 1280 142 0.63 A 2 1375 112 0.50 B 1 1210 160 0.71 B 2 1340 123 0.55 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal blower with flange (large) kg EC centrifugal, backward Dimensions Centrifugal fan kg Centrifugal blower with flange (small) R4E 180-AS11 -05 3.2 G4E 180-FS11 -01 — 6.4 188.0 168.0 134.0 — — — G4E 180-GS11 -01 6.4 278.0 258.0 224.0 180.0 C D E S EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 90.0 120,5 ±1 90 ±0,2 Depth of screw max. 10 mm EC centrifugal, forward 104 ±1 5 37 Ø180 Ø149 Ø102 35 6 EC-SYSTEMS 60 0± 20 Ø75 ±0,1 M6 92 Brass lead tips 183 129 296 90 7 163 133 Accessories Hole with large flange only E C D S ˚ 60 5˚ Technology 332 6x 192 Ø149 -1 600 136 3,2 155 121 Inlet nozzle p. 552 Guard grille p. 554 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts B AC centrifugal fan and blower single inlet, Ø 200 subject to alterations W A 230/400 230/400 230/400 230/400 50 60 50 60 1375 1360 1665 1220 1350 1530 1300 1550 285 360 360 340 1.00/0.58 1.13/0.65 1.14/0.66 1.07/0.62 (1) data collected via exhaust duct (step diffuser, 1 m length) Electr. connection rpm Perm. amb. temp. B m3/h Min. back pressure M4D 074-EI Hz Sound pressure level G4D 200 (1)(2) 3~ 3~ 3~ 3~ VAC Capacitor A Current draw M4D 074-EI Power input *4D 200 (2) Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings µF/VDB dB(A) Pa °C p. 596 f. 69 69 71 69 0 100 0 250 — — — — (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves 1,5 400 350 B 250 1,0 300 200 2 2 0,5 150 100 A 50 1 1 0 200 400 400 600 800 800 [CFM] 1200 [m3/h] 50 Hz 122 60 Hz -25 to +45 -25 to +45 -25 to +45 -25 to +40 n [rpm] P1 [W] I [A] A 1 1375 255 0.90/0.52 A 2 1415 192 0.68/0.39 B 1 1315 330 1.05/0.61 B 2 1385 230 0.74/0.43 C1)/C2) C1)/C2) General information AC centrifugal, backward Motor protection: Without thermal protection Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal blower with flange (large) kg EC centrifugal, backward Dimensions Centrifugal fan kg Centrifugal blower with flange (small) R4D 200-AL12 -05 3.7 G4D 200-BL12 -01 — 7.0 200.0 180.0 146.0 — — — G4D 200-CL12 -01 7.0 304.0 284.0 250.0 180.0 C D E S EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 90.0 129 ± 1 90 ± 0,2 Depth of screw max. 10 mm EC centrifugal, forward 117± 1 5 37 Ø202 Ø176 Ø102 48 6 EC-SYSTEMS 60 0± 20 Ø75 ± 0,1 M6 102 Brass lead tips 196,5 142,5 327 90 146 Accessories Hole with large flange only 7 176,5 E C D S ˚ 60 5˚ Technology 370 6x 213 Ø 175 600 151 3,2 160,5 123 Inlet nozzle p. 552 Terminal box p. 562 Electr. connections p. 596 f. Contacts B AC centrifugal fans and blowers single inlet, Ø 200 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1370 1315 1540 1300 1300 1480 1240 1430 280 350 330 370 1.25 1.55 1.45 1.62 8.0 /400 8.0 /400 8.0 /400 8.0 /400 69 69 70 68 0 100 0 170 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *4E 200 M4E 074-EI A G4E 200 (1) M4E 074-EI B subject to alterations 1~ 1~ 1~ 1~ (1) data collected via exhaust duct (step diffuser, length 1 m) 2 [Pa] [in H O] Curves 1,5 400 350 B 1,0 300 250 200 2 2 0,5 150 A 100 50 1 1 0 200 400 400 600 800 800 1200 [CFM] [m3/h] 50 Hz 124 -25 to +40 -25 to +40 -25 to +50 -25 to +40 60 Hz n [rpm] P1 [W] I [A] A 1 1350 258 1.15 A 2 1400 214 0.96 B 1 1285 303 1.33 B 2 1370 242 1.07 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Axial Protection class: I Capacitor: FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: CCC, B also GOST Centrifugal blower with flange (large) kg EC centrifugal, backward Dimensions Centrifugal fan kg Centrifugal blower with flange (small) R4E 200-AL03 -05 3.7 G4E 200-BL03 -01 — 7.0 200.0 180.0 146.0 — — — G4E 200-CL03 -01 7.0 304.0 284.0 250.0 180.0 C D E S EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – – 90.0 129 ± 1 90 ± 0,2 Depth of screw max. 10 mm EC centrifugal, forward 117± 1 5 37 Ø202 Ø176 Ø102 48 6 EC-SYSTEMS 60 0± 20 Ø75 ± 0,1 M6 102 Brass lead tips 196,5 142,5 327 90 146 Accessories Hole with large flange only 7 176,5 E C D S ˚ 60 5˚ Technology 370 6x 213 Ø 175 600 151 3,2 160,5 125 Inlet nozzle p. 552 Capacitor p. 560 f. Terminal box p. 562 Electr. connections p. 596 f. Contacts B AC centrifugal fan and blower single inlet, Ø 225 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 400 Y 400 Y 400 Y 400 Y 50 60 50 60 1350 1500 1310 1520 380 540 460 515 0.75 0.94 0.85 0.90 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *4D 225 M4D 094-FA A G4D 225 (2) M4D 094-FA B subject to alterations 3~ 3~ 3~ 3~ (1) Nominal data in operating point with maximum load — — — — 0 50 0 200 -40 to +90 -40 to +55 -40 to +75 -40 to +60 1,0 300 2 2 200 0,5 A 100 1 0 250 400 500 800 1 750 1200 1000 1600 50 Hz 126 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1380 325 0.69 71 A 2 1420 228 0.60 67 B 1 1345 388 0.76 74 B 2 1400 271 0.64 69 2 [Pa] [in H O] 1,5 B D2) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 400 D2) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Options: B 400 VAC ∆/Y for two speed steps available on request kg EC centrifugal, backward Centrifugal fan kg R4D 225-AK10 -06 6.5 G4D 225-FK10 -03 — 9.5 200.0 180.0 146.0 — — — G4D 225-GK10 -03 9.7 304.0 284.0 250.0 180.0 C D E S 90.0 137,5 ±2 128 ±2 225 ±2 Ø124 Ø195 ±1 50 60 0 Ø100 +0,5 15 Ø1 EC centrifugal, forward 5,5 Centrifugal blower with flange (large) Dimensions Centrifugal blower with flange (small) EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 45˚ M6 Depth of screw max. 12 mm EC-SYSTEMS 102 Brass lead tips 196,5 142,5 327 90 Accessories 158 E ˚ 60 6x 5˚ 370 0 60 Technology 7 176,5 151 Ø194 242 3,2 166,5 5,5 127 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts Hole with large flange only C D S B AC centrifugal fan and blower single inlet, Ø 225 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1330 1500 1260 1470 395 500 485 510 1.98 2.30 2.30 2.30 6.0 /450 6.0 /450 6.0 /450 6.0 /450 0 100 0 200 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *4E 225 M4E 094-FA A G4E 225 (2) M4E 094-FA B subject to alterations 1~ 1~ 1~ 1~ (1) Nominal data in operating point with maximum load -40 to +70 -40 to +50 -40 to +55 -40 to +45 1,0 300 2 2 200 0,5 A 1 100 0 250 400 500 800 1 750 1200 1000 1600 50 Hz 128 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1365 339 1.75 67 A 2 1415 255 1.46 70 B 1 1320 401 2.00 74 B 2 1395 292 1.57 69 2 [Pa] [in H O] 1,5 B A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 400 A2a) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE kg EC centrifugal, backward Centrifugal fan kg R4E 225-BK05 -03 6.6 G4E 225-DK05 -03 — 9.6 200.0 180.0 146.0 — — — G4E 225-EK05 -03 9.8 304.0 284.0 250.0 180.0 C D E S 90.0 137,5 ±2 128 ±2 225 ±2 Ø124 Ø195 ±1 50 60 0 Ø100 +0,5 15 Ø1 EC centrifugal, forward 5,5 Centrifugal blower with flange (large) Dimensions Centrifugal blower with flange (small) EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – 45˚ M6 Depth of screw max. 12 mm EC-SYSTEMS 102 Brass lead tips 196,5 142,5 327 90 Accessories 158 E ˚ 60 6x 5˚ 370 0 60 Technology 7 176,5 151 Ø194 242 3,2 166,5 5,5 129 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Hole with large flange only C D S B AC centrifugal fan and blower single inlet, Ø 250 B subject to alterations Electr. connection M4D 094-HA Perm. amb. temp. G4D 250 (2) 3~ 3~ 3~ 3~ Min. back pressure A Capacitor M4D 094-HA Max. current draw (1) *4D 250 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 400 Y 400 Y 400 Y 400 Y 50 60 50 60 1350 1560 1280 1560 590 710 800 700 1.17 1.26 1.46 1.24 (1) Nominal data in operating point with maximum load — — — — 0 150 0 300 -40 to +80 -40 to +60 -40 to +50 -40 to +55 2 [Pa] [in H O] 2,0 1,5 400 B 300 2 1,0 2 200 A 1 0,5 1 100 0 250 400 500 750 1000 1000 1600 1250 [CFM] 2200 50 Hz 130 [m3/h] 60 Hz D2) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 D2) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1390 444 0.99 72 A 2 1430 312 0.87 70 B 1 1330 654 1.13 76 B 2 1410 386 0.94 71 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Options: 400 VAC ∆/Y for two speed steps available on request kg EC centrifugal, backward Centrifugal fan kg R4D 250-AC10 -03 9.7 G4D 250-DC10 -03 — 13.1 218.0 190.0 167.0 — — — G4D 250-EC10 -03 13.5 313.0 285.0 262.0 180.0 293.0 C D E S U 90.0 198.0 175,5 ±2 148 ±2 Ø240±2 Ø124 Ø192 ±1 70 60 0 Ø100 +0.5 15 Ø1 EC centrifugal, forward 5,5 Centrifugal blower with flange (large) Dimensions Centrifugal blower with flange (small) EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – – 45˚ EC-SYSTEMS M6 Depth of screw max. 12 mm Brass lead tips 227 206 176 387 90 7 207 194 Accessories Hole with large flange only E C U D S 0˚ 0 60 Technology 392 6x6 275 173 Ø200 B 3,2 205,5 5,5 131 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts 140 AC centrifugal fan and blower single inlet, Ø 250 B subject to alterations Electr. connection M4E 094-HA Perm. amb. temp. G4E 250(2) 1~ 1~ 1~ 1~ Min. back pressure A Capacitor M4E 094-HA Max. current draw (1) *4E 250 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1310 1470 1150 1400 570 690 760 730 2.48 3.05 3.80 3.30 10.0 /450 10.0 /450 10.0 /450 10.0 /450 0 100 0 220 (1) Nominal data in operating point with maximum load -40 to +70 -40 to +55 -40 to +45 -40 to +55 2 [Pa] [in H O] 2,0 1,5 400 300 2 1,0 2 B 200 0,5 1 1 A 100 0 250 400 500 750 1000 1000 1600 1250 [CFM] 2200 50 Hz 132 [m3/h] 60 Hz A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 A2a) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1370 448 2.25 70 A 2 1420 325 1.85 68 B 1 1310 560 2.73 73 B 2 1390 395 2.05 69 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE kg EC centrifugal, backward Centrifugal fan kg R4E 250-BA09 -03 9.3 G4E 250-DA09 -03 — 12.7 218.0 190.0 167.0 — — — G4E 250-EA09 -03 13.1 313.0 285.0 262.0 180.0 293.0 C D E S U 90.0 198.0 175,5 ±2 148 ±2 Ø240±2 Ø124 Ø192 ±1 70 60 0 Ø100 +0.5 15 Ø1 EC centrifugal, forward 5,5 Centrifugal blower with flange (large) Dimensions Centrifugal blower with flange (small) EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – 45˚ EC-SYSTEMS M6 Depth of screw max. 12 mm Brass lead tips 227 206 176 387 90 7 207 194 Accessories Hole with large flange only E C U D S 0˚ 0 60 Technology 392 6x6 275 173 Ø200 B 3,2 205,5 5,5 133 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 140 AC centrifugal fan and blowers single inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 850 900 780 760 220 295 255 305 1.00 1.30 1.15 1.35 6.0 /450 6.0 /500 6.0 /450 6.0 /500 0 0 0 0 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor *6E 250 M6E 094-FA A G6E 250 (2) M6E 094-FA B subject to alterations 1~ 1~ 1~ 1~ (1) Nominal data in operating point with maximum load -40 to +80 -40 to +80 -40 to +80 -40 to +70 0,5 150 2 2 100 0,25 A 1 1 50 0 250 400 500 800 750 1200 1000 1600 50 Hz 134 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 900 180 0.82 63 A 2 930 156 0.74 61 B 1 855 215 0.96 65 B 2 910 173 0.79 62 2 [Pa] [in H O] 0,75 B A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 200 A2a) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE kg EC centrifugal, backward Centrifugal fan kg R6E 250-AK05 -03 7.0 G6E 250-DK05 -03 — 10.5 218.0 190.0 167.0 — — — G6E 250-EK05 -03 10.9 313.0 285.0 262.0 180.0 293.0 C D E S U 90.0 198.0 175,5 ±2 128 ±2 Ø240±2 Ø124 Ø192 ±1 50 60 0 Ø100 +0.5 15 Ø1 EC centrifugal, forward 5,5 Centrifugal blower with flange (large) Dimensions Centrifugal blower with flange (small) EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – 45˚ EC-SYSTEMS M6 Depth of screw max. 12 mm Brass lead tips 227 206 176 387 90 7 207 194 Accessories Hole with large flange only E C U D S 0˚ 0 60 Technology 392 6x6 275 173 Ø200 B 3,2 205,5 5,5 135 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 140 AC centrifugal fans single inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 1400 0.75 2.77/1.60 B 1~ 230 1270 0.64 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 250 (2) M4D 110-GF R4E 250 M4E 110-GF subject to alterations 50 (1) Nominal data in operating point with maximum load 2.80 — 12.0 /450 0 -25 to +80 D1)/D2) 0 -25 to +80 A2a) (2) 230 VAC ∆ / 400 VAC Y 2 1,4 [Pa] 300 2 2 1,2 350 [in H O] Curves 1,0 A 250 B 1 0,4 0,6 100 50 0,2 150 0,8 1 200 0 250 400 136 500 800 750 1200 1000 1600 1250 2000 [CFM] [m3/h] n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 1430 0.53 2.48/1.43 77 A 2 1460 0.32 2.23/1.29 70 B 1 1370 0.49 2.14 76 B 2 1430 0.33 1.49 70 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R4D 250-CG01 -01 R4E 250-CG01 -01 Inlet nozzle Flange 12.0 25010-2-4013 94250-2-4017 12.0 25010-2-4013 94250-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 150 4x90˚ 30˚ Ø 130 147 28 137 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 30 ˚ 158 170 184 Technology 203 30 ˚ 30˚ ˚ 30 198 18 30˚ 30˚ 0 10 30˚ 213 5 138 Ø 65 ˚ 11 30˚ 25˚ 230 Ø 267 247 287 Ø7 AC centrifugal fans single inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection Type Motor R6D 250 (2) M6D 110-EF R6E 250 M6E 094-FA subject to alterations Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 930 0.27 1.25/0.72 B 1~ 230 800 0.26 50 (1) Nominal data in operating point with maximum load 1.16 — 0 -25 to +95 D1)/D2) 6.0 /450 0 -25 to +90 A2a) (2) 230 VAC ∆ / 400 VAC Y [Pa] [in H2O] Curves A 160 0,6 B 2 2 0,4 120 80 0,2 11 40 B A 200 0 200 138 400 400 600 none VAC Curve Nominal data B Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: A cast in aluminium, B coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: A on rotor and stator sides, – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 600 800 1000 800 1200 1400 [CFM] [m3/h] n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 945 0.23 1.18/0.68 68 A 2 965 0.17 1.11/0.64 63 B 1 875 0.22 1.00 67 B 2 930 0.17 0.81 62 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: A VDE (acc. to EN 60034) EC centrifugal, backward Dimensions Centrifugal fan kg l R6D 250-CE01 -01 9.5 R6E 250-CA08 -01 7.0 Inlet nozzle Flange 800.0 25010-2-4013 94250-2-4017 600.0 25010-2-4013 94250-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 150 Mounting dimensions B A 55 Ø 130 4x90˚ 4x90˚ 30˚ 28 28 139 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 30 ˚ 158 170 184 Technology 203 30 ˚ 0 10 30˚ 5 Ø 147 11 ˚ 30 198 Ø 18 30˚ 30˚ 0 10 30˚ 213 5 138 Ø 65 ˚ 11 30˚ 25˚ 230 Ø7 Ø 267 247 287 Ø7 AC centrifugal fan and blower single inlet, Ø 280 subject to alterations Capacitor Min. back pressure Perm. amb. temp. Electr. connection M4E 094-HA Max. current draw (1) *4E 280 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 50 60 1100 1350 1080 990 5.30 4.70 12.0 /400 12.0 /450 100 400 1~ 230 1~ 230 A -40 to +60 -40 to +55 (1) Nominal data in operating point with maximum load 3,0 800 600 2,0 A 2 400 1,0 1 200 200 400 400 600 800 800 1200 1000 1600 1200 2000 50 Hz 140 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1250 845 4.20 73 A 2 1380 555 3.02 73 2 [Pa] [in H O] Curves 0 A2a) General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Centrifugal fan kg Centrifugal blower with flange (small) kg R4E 280-CC21 -01 10.2 G4E 280-CA21 -01 14.0 5,5 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – – – – 149,5 ±2 148 ±2 EC centrifugal, forward Ø280±2 Ø124 Ø234 ±1 60 0 Ø100 +0.5 15 Ø1 70 45˚ EC-SYSTEMS M6 Depth of screw max. 12 mm Brass lead tips 200 176 149 412 100 Accessories M6 0 60 Technology 444 10 280 348 322 316 200 180 190 175 Ø236 315 5x6 0˚ 172 3,5 141 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 114 AC centrifugal fans single inlet, Ø 280 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 1330 1.32 4.75/2.75 B 1~ 230 1230 1.05 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 280 (2) M4D 110-IA R4E 280 M4E 110-IA subject to alterations 50 (1) Nominal data in operating point with maximum load 4.75 — 16.0 /450 0 -25 to +65 D1)/D2) 100 -25 to +50 A2a) (2) 230 VAC ∆ / 400 VAC Y 1390 0.87 3.79/2.19 77 2 1440 0.51 3.29/1.90 72 B 1 1340 0.82 3.59 76 B 2 1425 0.54 2.34 72 2 [Pa] 1 2,0 1,6 B 1 200 0,8 100 0,4 1,2 1 300 0 500 500 142 LpA [dB(A)] A A 400 I [A] A 2 500 P1 [kW] [in H O] 600 n [rpm] 2,4 Curves 1000 1000 1500 [CFM] 1500 2000 2500 3000 [m3/h] General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R4D 280-CI03 -01 R4E 280-CI01 -01 Inlet nozzle Flange 14.5 28010-2-4013 10280-2-4017 14.5 28010-2-4013 10280-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 180 4x90˚ 30˚ Ø 130 152 28 143 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts ˚ 30 148 161 172 ˚ 30 183 Technology 205 30 ˚ 30˚ 13 30˚ 30˚ 0 10 30˚ 200 5 162 Ø 65 ˚ 11 30˚ 25˚ 218 Ø 254 236 266 Ø7 AC centrifugal fans single inlet, Ø 280 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection Type Motor R6D 280 (2) M6D 110-EF R6E 280 M6E 094-HA subject to alterations Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 870 0.45 1.56/0.90 B 1~ 230 795 0.42 50 (1) Nominal data in operating point with maximum load 1.95 — 12.0 /450 0 -25 to +70 D1)/D2) 0 -25 to +55 A2a) (2) 230 VAC ∆ / 400 VAC Y 2 1,25 [Pa] [in H O] Curves 2 2 A 0,75 200 1,0 300 250 B 1 150 0,5 1 0,25 100 50 0 400 400 144 800 800 none VAC Curve Nominal data B Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: A cast in aluminium, B coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: A on rotor and stator sides, – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 1200 1200 1600 2000 [CFM] [m3/h] n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 930 0.29 1.30/0.75 66 A 2 960 0.18 1.16/0.67 61 B 1 890 0.34 1.60 66 B 2 940 0.27 1.37 61 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: A VDE (acc. to EN 60034) EC centrifugal, backward Dimensions Centrifugal fan kg l R6D 280-CE01 -01 10.0 R6E 280-CC05 -01 9.5 Inlet nozzle Flange 800.0 28010-2-4013 10280-2-4017 600.0 28010-2-4013 10280-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 180 Mounting dimensions B A 55 Ø 130 4x90˚ 4x90˚ 30˚ 28 28 145 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts ˚ 30 148 161 172 Technology 205 30 ˚ 0 10 30˚ 5 Ø 152 11 ˚ 30 183 Ø 13 30˚ 30˚ 0 10 30˚ 200 5 162 Ø 65 ˚ 11 30˚ 25˚ 218 Ø7 Ø 254 236 266 Ø7 AC centrifugal fan single inlet, Ø 310 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. 3~ 230/400 50 1310 2.18 6.75/3.90 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 310 (2) M4D 138-HF subject to alterations A (1) Nominal data in operating point with maximum load — 0 -25 to +55 (2) 230 VAC ∆ / 400 VAC Y A 2 [Pa] [in H O] Curves 600 300 1,2 200 0,8 400 1,6 500 2,0 2 0,4 1 100 0 500 1000 146 1000 1500 2000 2000 3000 2500 4000 [CFM] [m3/h] D1)/D2) n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 1330 1.96 6.29/3.63 82 A 2 1410 1.12 4.43/2.56 77 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R4D 310-CK03 -01 24.5 Inlet nozzle Flange 31010-2-4013 38310-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 18 mm Scroll housing used: 30 ˚ 65 ˚ 18 186 30˚ 30˚ 176 30 30˚ 30˚ 200 147 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts 214 229 246 ˚ 30 ˚ 30˚ 264 Technology 30˚ 25˚ 283 249 325 303 349 184 AC centrifugal fans single inlet, Ø 310 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 840 0.76 2.50/1.45 B 1~ 230 800 0.77 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 310 (2) M6D 110-GF R6E 310 M6E 110-IA subject to alterations 50 (1) Nominal data in operating point with maximum load 3.37 — 16.0 /400 50 -25 to +50 D1)/D2) 0 -25 to +65 A2a) (2) 230 VAC ∆ / 400 VAC Y 1 870 0.65 2.25/1.30 72 2 930 0.40 1.75/1.01 67 B 1 900 0.58 2.81 70 B 2 950 0.42 2.32 65 2 [Pa] LpA [dB(A)] A 250 1,0 200 0,8 2 1 0,6 A B 100 0,4 50 0,2 1 0 250 500 148 I [A] A 2 150 P1 [kW] [in H O] 300 n [rpm] 1,2 Curves 500 1000 1000 750 1500 1250 2000 1500 2500 1750 [CFM] 3000 [m3/h] General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R6D 310-CG03 -01 R6E 310-CI01 -01 Inlet nozzle Flange 12.5 31010-2-4013 10310-2-4017 15.0 31010-2-4013 10310-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 184 4x90˚ 30˚ Ø 130 186 28 149 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts ˚ 30 200 214 229 ˚ 30 246 Technology 249 30 ˚ 30˚ 18 30˚ 30˚ 0 10 30˚ 264 5 176 Ø 65 ˚ 11 30˚ 25˚ 283 Ø 325 303 349 Ø7 AC centrifugal fan single inlet, Ø 355 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. 3~ 230/400 50 1300 4.36 13.75/7.95 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 355 (2) M4D 138-LA subject to alterations A (1) Nominal data in operating point with maximum load — 0 -25 to +70 (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves A 2 600 2,4 500 2,0 700 2,8 800 0,8 1,2 200 100 0,4 300 1,6 1 400 0 1000 1000 150 2000 2000 3000 3000 4000 5000 4000 6000 7000 [CFM] [m3/h] D1)/D2) n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 1370 3.20 10.58/6.11 86 A 2 1430 1.89 7.52/4.34 80 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R4D 355-CM03 -01 28.0 Inlet nozzle Flange 35510-2-4013 38355-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 18 mm Scroll housing used: 30 ˚ 65 ˚ 18 207 30˚ 30˚ 196 30 30˚ 30˚ 222 151 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts 238 256 274 ˚ 30 ˚ 30˚ 294 Technology 30˚ 25˚ 315 280 362 338 389 203 AC centrifugal fans single inlet, Ø 355 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 865 0.90 3.05/1.77 B 1~ 230 830 0.83 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: On rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 355 (2) M6D 110-IA R6E 355 M6E 110-IA subject to alterations 50 (1) Nominal data in operating point with maximum load 3.90 — 16.0 /400 250 -25 to +50 D1)/D2) 175 -25 to +55 A2a) (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves 400 2 2 1,2 1 300 A 200 0,8 B 100 0,4 1 0 500 1000 152 1000 1500 2000 2000 3000 2500 4000 [CFM] [m3/h] n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 890 0.78 2.82/1.63 70 A 2 920 0.59 2.44/1.41 68 B 1 830 0.83 3.90 70 B 2 890 0.61 2.90 67 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Diagonal Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R6D 355-CI05 -01 R6E 355-CI01 -01 Inlet nozzle Flange 15.5 35510-2-4013 10355-2-4017 15.5 35510-2-4013 10355-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 12 mm Scroll housing used: Mounting dimensions 203 4x90˚ 30˚ Ø 130 207 28 153 Inlet nozzle p. 552 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts ˚ 30 222 238 256 ˚ 30 274 Technology 280 30 ˚ 30˚ 18 30˚ 30˚ 0 10 30˚ 294 5 196 Ø 65 ˚ 11 30˚ 25˚ 315 Ø 362 338 389 Ø7 AC centrifugal fan single inlet, Ø 400 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. 3~ 230/400 50 1210 4.92 14.70/8.50 Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R4D 400 (2) M4D 138-NA subject to alterations A (1) Nominal data in operating point with maximum load — 550 (3) -25 to +35 (2) 230 VAC ∆ / 400 VAC Y (3) without voltage control 4,0 800 3,2 2 1000 600 2,4 [Pa] [in H O] Curves A 2 400 1,6 200 0,8 1 0 1000 2000 2000 3000 4000 4000 6000 5000 8000 [CFM] [m3/h] ohne Spannungssteuerung einsetzbar 154 D1)/D2) n [rpm] P1 [kW] I [A] LpA [dB(A)] A 1 1210 4.92 14.70/8.50 87 A 2 1300 3.70 11.19/6.46 86 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R4D 400-CO01 -01 32.5 Inlet nozzle Flange 40010-2-4013 38400-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 18 mm Scroll housing used: 30 ˚ 65 ˚ 20 233 30˚ 30˚ 220 30 30˚ 30˚ 250 155 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts 268 288 308 ˚ 30 ˚ 30˚ 331 Technology 30˚ 25˚ 355 316 408 380 437 228 AC centrifugal fans single inlet, Ø 400 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 596 f. A 3~ 230/400 50 840 2.40 8.47/4.90 — 0 -25 to +75 D1)/D2) B 3~ 230/400 50 615 0.89 3.46/2.00 — 100 -25 to +65 D1)/D2) Curve Nominal voltage – Material: Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: A IP 20, B IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Any – Condensate discharge holes: A none, B on rotor and stator sides – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R6D 400 (2) M6D 138-LA R8D 400 (2) M8D 138-HF subject to alterations (1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves 500 1,6 300 1,2 A 2 0,8 1 200 B 1 0,4 100 0 500 1000 156 1000 2000 1500 2000 3000 2500 4000 3000 5000 3500 [CFM] 6000 [m3/h] P1 [kW] I [A] LpA [dB(A)] A 1 890 1.86 7.10/4.10 80 A 2 940 1.16 5.51/3.18 74 B 1 615 0.89 3.46/2.00 71 B 2 675 0.60 2.74/1.58 67 2 400 n [rpm] General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Lateral Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Centrifugal fan kg R6D 400-CM05 -01 R8D 400-CK05 -01 Inlet nozzle Flange 29.0 40010-2-4013 38400-2-4017 26.0 40010-2-4013 38400-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – – – – – Brass lead tips View Z Accessories Housing width Depth of screw max. 18 mm Scroll housing used: 30 ˚ 65 ˚ 20 233 30˚ 30˚ 220 30 30˚ 30˚ 250 157 Inlet nozzle p. 552 Electr. connections p. 596 f. Contacts 268 288 308 ˚ 30 ˚ 30˚ 331 Technology 30˚ 25˚ 355 316 408 380 437 228 AC centrifugal blowers dual inlet, Ø 140 Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 470 430 1150 1050 130 130 0.58 0.58 2.0 /400 2.0 /400 58 56 0 0 n [rpm] P1 [W] I [A] LpA [dB(A)] 1~ 230 1~ 230 -25 to +50 -25 to +40 Electr. connection Capacitor A Current draw M2E 068-CF Power input D2E 140 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PP plastic, white Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, standard external-rotor motor anti-vibration mounted on one side – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves 1,5 400 300 p4 Ste 1,0 2 4 p3 Ste 200 0,5 6 1 Ste p2 100 ep St 8 3 1 5 7 0 100 100 200 200 300 300 400 500 50 Hz 158 [CFM] [m3/h] 60 Hz A 1 1675 118 0.51 56 A 2 2235 100 0.43 59 A 3 1385 93 0.41 52 A 4 2020 80 0.36 56 A 5 1000 73 0.33 46 A 6 1540 68 0.31 49 A 7 690 56 0.26 36 A 8 1015 55 0.25 38 General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE D2E 140-HR97 -07 2.3 EC centrifugal, backward for clean rooms kg View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 159 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 520 375 1350 1400 120 125 0.53 0.55 3.0 /400 3.0 /400 51 53 50 100 1~ 230 1~ 230 A -25 to +55 -25 to +40 Electr. connection Current draw M2E 068-CA Power input D2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PA plastic, red-brown Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, standard external-rotor motor anti-vibration mounted via support plate – Bearings: Maintenance-free ball bearings — subject to alterations 2 [Pa] A 1,2 300 [in H O] Curves 2 250 0,8 p4 Ste 200 4 150 p3 Ste 1 6 0,4 100 p Ste 2 3 Ste 8 50 p1 5 7 0 100 100 160 200 200 300 300 400 [CFM] 500 [m3/h] 50 Hz 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1635 113 0.49 55 A 2 2115 104 0.45 58 A 3 1210 72 0.36 48 A 4 1740 66 0.35 53 A 5 925 58 0.31 40 A 6 1355 55 0.30 47 A 7 660 48 0.27 31 A 8 960 46 0.26 38 General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE D2E 146-KA45 -01 2.5 EC centrifugal, backward for clean rooms kg View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 161 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 665 390 1250 1950 160 170 0.70 0.75 4.0 /400 4.0 /400 53 58 0 200 1~ 230 1~ 230 A -25 to +50 -25 to +40 Electr. connection Current draw M2E 068-CF Power input D2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PA plastic, red-brown Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, standard external-rotor motor anti-vibration mounted via support plate – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves 400 Ste p4 300 St ep ep St 0,8 2 4 Ste p1 150 6 1 0,4 100 3 50 8 5 7 0 100 100 200 200 300 300 400 500 [CFM] 600 50 Hz 162 I [A] LpA [dB(A)] A 1 1675 151 0.66 59 A 2 2185 136 0.60 62 A 3 1230 101 0.50 50 A 4 1800 92 0.47 55 A 5 950 85 0.43 43 A 6 1440 80 0.42 49 A 7 660 71 0.37 31 A 8 960 68 0.36 38 2 3 250 200 P1 [W] 1,2 350 n [rpm] [m3/h] 60 Hz General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE D2E 146-KB27 -01 2.7 EC centrifugal, backward for clean rooms kg View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 163 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 630 415 1100 1600 150 160 0.66 0.71 4.0 /400 4.0 /400 51 55 0 150 1~ 230 1~ 230 A -25 to +50 -25 to +45 Electr. connection Current draw M2E 068-CF Power input D2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PP plastic, white Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Counter-clockwise, seen on plug – Type of protection: IP 20 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, EW motor – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves 1,5 400 300 1,0 2 St 200 4 ep 4 p3 0,5 Ste 6 100 1 p Ste St 2 8 ep 3 1 5 7 0 100 100 200 200 300 300 400 500 50 Hz 164 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1490 143 0.62 51 A 2 2005 133 0.59 55 A 3 1110 98 0.49 47 A 4 1635 92 0.47 49 A 5 890 81 0.42 37 A 6 1315 77 0.42 43 A 7 680 69 0.38 31 A 8 990 67 0.37 35 General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE, CCC, GOST D2E 146-HR93 -03 3.0 EC centrifugal, backward for clean rooms kg View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 165 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 755 580 1350 1750 195 215 0.86 0.94 5.0 /400 5.0 /400 57 54 0 150 1~ 230 1~ 230 A -25 to +55 -25 to +40 Electr. connection Current draw M2E 068-DF Power input D2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PP plastic, white Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Counter-clockwise, seen on plug – Type of protection: IP 20 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, EW motor – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves Step 4 400 Ste 1,5 p3 1,0 4 Step 200 2 Step 0,5 1 1 6 100 8 3 5 7 0 100 200 200 300 400 400 600 50 Hz 166 [CFM] [m3/h] 60 Hz P1 [W] I [A] LpA [dB(A)] A 1 1790 185 0.81 56 A 2 2290 164 0.72 59 A 3 1210 125 0.60 45 A 4 1820 112 0.57 52 A 5 910 106 0.52 38 A 6 1415 100 0.50 45 A 7 710 94 0.47 30 A 8 1055 91 0.46 38 2 300 n [rpm] General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE, GOST 3.5 View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 167 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward D2E 146-HS97 -03 kg EC centrifugal, backward for clean rooms Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 1060 875 1850 2100 355 400 1.55 1.75 8.0 /450 8.0 /450 66 63 0 200 1~ 230 1~ 230 A -25 to +50 -25 to +55 Electr. connection Current draw M2E 068-EC Power input D2E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Counter-clockwise, seen on plug – Type of protection: IP 20 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, EW motor – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves 500 Step 4 Step 3 400 1,5 St ep 1 2 4 1,0 300 6 200 0,5 1 8 3 100 5 7 0 150 200 300 400 450 600 [CFM] 800 [m3/h] 50 Hz 168 60 Hz P1 [W] I [A] LpA [dB(A)] A 1 2075 328 1.42 66 A 2 2430 269 1.17 61 A 3 1770 268 1.20 61 A 4 2230 222 1.04 62 A 5 1375 225 1.03 54 A 6 1885 197 0.94 57 A 7 1000 192 0.88 45 A 8 1415 180 0.84 49 Ste p2 n [rpm] General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: VDE D2E 146-HT67 -02 3.6 EC centrifugal, backward for clean rooms kg View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 1 2 red 3 grey black blue green/yellow 6 PE 5 1 2 3 N 4 Speed increase 4 5 6 L1 169 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 6 Electrical connection: When changing speeds, switch must break the circuit Technology Accessories 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 160 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 400 1170 110 0.49 2.5 /400 53 100 1~ 230 A -25 to +55 Electr. connection Current draw M2E 068-BF Power input D2E 160 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, standard external-rotor motor anti-vibration mounted on one side – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] [in H O] Curves 1,5 400 300 1,0 2 St 200 ep 3 Ste p2 0,5 4 Step 1 1 6 100 3 8 5 7 0 50 100 100 150 200 200 300 250 400 50 Hz 170 [CFM] [m3/h] 60 Hz P1 [W] I [A] LpA [dB(A)] A 1 1210 108 0.47 51 A 2 1735 102 0.44 55 A 3 910 74 0.35 43 A 4 1345 71 0.34 48 A 5 765 64 0.31 38 A 6 1135 61 0.30 44 A 7 555 50 0.26 30 A 8 835 49 0.25 36 Ste p4 n [rpm] General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: CCC, GOST D2E 160-FI01 -01 2.5 EC centrifugal, backward for clean rooms kg 1 2 3 4 5 6 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 3 2 1 red grey black blue green/yellow 6 5 4 Electrical connection: When changing speeds, switch must break the circuit 6 PE 5 1 2 3 N 4 Speed increase L1 171 Connection lead p. 558 Capacitor p. 560 f. Contacts View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 Technology Accessories 5x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 160 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 550 1400 180 0.80 4.0 /400 59 150 1~ 230 A -25 to +40 Electr. connection Current draw M2E 068-CF Power input D2E 160 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 4-step blower with integrated terminal box, standard external-rotor motor anti-vibration mounted on one side – Bearings: Maintenance-free ball bearings — subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves Ste 1,5 2 300 St 3 1,0 ep 200 St ep 4 2 0,5 1 Ste 100 6 p1 3 8 5 7 0 100 100 200 200 300 300 400 500 50 Hz 172 [CFM] [m3/h] 60 Hz P1 [W] I [A] LpA [dB(A)] A 1 1400 180 0.80 59 A 2 1920 162 0.70 60 A 3 1010 120 0.56 48 A 4 1450 113 0.53 52 A 5 770 96 0.46 40 A 6 1115 93 0.45 44 A 7 500 76 0.38 28 A 8 740 75 0.37 34 p4 400 n [rpm] General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-2-31, CE Approvals: CCC, GOST D2E 160-FK11 -02 3.0 EC centrifugal, backward for clean rooms kg 1 2 3 4 5 6 = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 (max.) N Protective earth white 3 2 1 red grey black blue green/yellow 6 5 4 Electrical connection: When changing speeds, switch must break the circuit 6 PE 5 1 2 3 N 4 Speed increase L1 173 Connection lead p. 558 Capacitor p. 560 f. Contacts View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 926 682-3 6 x plug pin: AMP 926 886-1 Technology Accessories 5x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) EC-SYSTEMS EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 60 565 510 780 710 65 68 0.29 0.30 2.0 /400 2.0 /400 46 42 0 0 n [rpm] P1 [W] I [A] LpA [dB(A)] 1~ 230 1~ 230 A -25 to +50 -25 to +40 Electr. connection Current draw M4E 068-CF Power input D4E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller: PA plastic, black Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Counter-clockwise, seen on cable exit – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 5-step blower with integrated terminal box, EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings — subject to alterations A 2 [Pa] 120 [in H O] Curves Step 5 100 0,4 Step 4 Ste p3 2 St ep 2 80 0,3 4 6 0,2 60 1 ep St 1 40 0,1 8 20 3 5 10 7 9 0 100 100 174 200 200 300 300 400 [CFM] 500 [m3/h] 50 Hz 60 Hz A 1 1080 58 0.25 45 A 2 1345 43 0.19 46 A 3 695 52 0.23 33 A 4 1210 39 0.18 43 A 5 560 48 0.22 26 A 6 1080 40 0.19 39 A 7 450 20 0.16 21 A 8 735 20 0.16 29 A 9 315 13 0.13 17 A 10 475 13 0.13 20 General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-1, CE D4E 146-LV19 -14 2.5 EC centrifugal, backward for clean rooms kg EC centrifugal, forward Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – Accessories X EC-SYSTEMS 4x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) = = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 Step 5 (max.) N Protective earth 7 8 9 9 8 1 2 3 4 5 PE N Speed increase 6 4 5 1 2 L1 3 175 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 8 9 Electrical connection: When changing speeds, switch must break the circuit Technology View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 927 231-3 7 x plug pin: AMP 926 886-1 AC centrifugal blowers dual inlet, Ø 146 Capacitor Sound pressure level Min. back pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 50 1180 750 85 0.38 2.5 /450 47 0 n [rpm] P1 [W] I [A] LpA [dB(A)] 1~ 230 A -25 to +50 Electr. connection Current draw M4E 068-DF Power input K4E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black Impeller / motor suspension: PA plastic, black Rotor: Partially cast in aluminium Terminal box: PP plastic, black – Direction of rotation: Counter-clockwise, seen on cable exit – Type of protection: IP 44 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: 5-step dual blower with integrated terminal box, standard external-rotor motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings — subject to alterations 2 [Pa] 100 A 0,4 120 [in H O] Curves Ste p5 2 0,3 80 1 1050 76 0.33 45 A 2 1240 65 0.28 46 A 3 810 59 0.27 39 A 4 1060 51 0.24 41 A 5 570 47 0.22 29 A 6 820 43 0.21 35 A 7 400 13 0.15 25 A 8 580 13 0.15 28 A 9 330 10 0.13 25 A 10 480 10 0.13 26 p e St A 4 60 4 p3 0,2 Ste 1 ep St 40 2 6 e St 3 0,1 p1 20 8 5 10 9 0 200 200 176 7 400 400 600 800 600 [CFM] 1000 [m3/h] 50 Hz 60 Hz General information AC centrifugal, backward Motor protection: TOP wired internally Connection leads: Via plug Protection class: I Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in Product conforming to standards: EN 60335-1, CE Approvals: CCC K4E 146-AB73 -21 4.0 EC centrifugal, backward for clean rooms kg EC-SYSTEMS EC centrifugal, forward Dual centrifugal blower with flange EC centrifugal, backward Mass of dual centrifugal blower AC centrifugal, forward – – – – – – X = = = = = = = Step 1 (min.) Step 2 Step 3 Step 4 Step 5 (max.) N Protective earth 3 2 1 9 8 1 2 3 4 5 PE N Speed increase 4 6 5 9 8 L1 7 177 Guard grille p. 556 Connection lead p. 558 Capacitor p. 560 f. Contacts 1 2 3 4 5 8 9 Electrical connection: When changing speeds, switch must break the circuit Technology View X AMP Universal Mate-N-Lok coded plug system Connector shell: AMP 927 231-3 7 x plug pin: AMP 926 886-1 Accessories 8x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus thickness of mounting material) AC centrifugal blowers dual inlet, Ø 097 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 230 230 50 60 50 60 50 60 180 170 300 280 435 410 1550 1450 1350 1250 1950 1850 28 32 50 55 87 100 0.13 0.15 0.23 0.25 0.39 0.45 1.0 /400 1.0 /400 1.5 /400 1.5 /400 2.0 /400 2.0 /400 46 44 50 48 58 57 0 0 0 0 0 0 n [rpm] P1 [W] I [A] Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings Nominal data Type Motor D2E 097 M2E 052-BF A D2E 097 M2E 052-BF B D2E 097 M2E 052-CA C 1~ 1~ 1~ 1~ 1~ 1~ -25 to +85 -25 to +80 -25 to +70 -25 to +55 -25 to +40 -25 to +35 subject to alterations 2 [Pa] [in H O] Curves 200 C 0,75 250 1,0 300 150 0,5 2 100 2 2 0,25 B 50 1 A 1 0 50 100 1 100 150 200 200 [CFM] 300 400 50 Hz 178 [m3/h] 60 Hz A 1 1670 27 0.13 A 2 2080 25 0.12 B 1 1490 48 0.22 B 2 2000 44 0.20 C 1 2150 83 0.37 C 2 2475 73 0.33 A1) A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: C CCC, GOST EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – Centrifugal blower with flange kg D2E 097-CH85 -02 D2E 097-CH85 -48 1.5 140.0 128.0 D2E 097-BK66 -02 D2E 097-BK66 -48 D2E 097-BI56 -02 D2E 097-BI56 -48 A B C D E H I K 78.0 66.0 46.0 80.0 108.0 144.0 1.5 180.0 168.0 100.0 88.0 67.0 1.5 180.0 168.0 100.0 88.0 67.0 L M N O P 76.0 137.0 62.0 96.0 51.0 79.5 146.0 162.0 86.0 165.0 68.0 114.0 62.5 79.5 146.0 162.0 86.0 165.0 68.0 114.0 62.5 EC centrifugal, backward for clean rooms Dimensions Centrifugal blower without flange A B L 1 5,5 E N ØH M P EC-SYSTEMS O C D EC centrifugal, forward K Accessories I Technology Brass lead tips 179 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 200 AC centrifugal blowers dual inlet, Ø 133 Perm. amb. temp. Electr. connection B Min. back pressure M2E 068-DF Sound pressure level D2E 133 1~ 1~ 1~ 1~ Capacitor A Current draw M2E 068-CF Power input D2E 133 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: A Counter-clockwise, B clockwise seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 700 500 685 510 1700 2100 1500 1800 175 190 190 200 0.77 0.84 0.84 0.88 4.0 /400 4.0 /400 3.0 /450 3.0 /450 58 58 59 56 50 200 0 100 -25 to +40 -25 to +40 -25 to +45 -25 to +40 subject to alterations 2 [Pa] [in H O] Curves 500 1,5 400 300 2 2 1,0 A B 1 0,5 200 100 1 0 100 200 200 300 400 [CFM] 600 50 Hz 180 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2135 160 0.70 A 2 2450 138 0.61 B 1 1885 180 0.80 B 2 2640 130 0.58 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, B also GOST EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – Centrifugal blower with flange kg D2E 133-CI33 -56 D2E 133-CI33 -22 3.3 206.0 190.0 142.0 126.0 102.0 168.0 400.0 204.0 D2E 133-AM47 -01 D2E 133-AM47 -23 3.5 254.0 238.0 108.0 A B C D 92.0 E I J K 69.0 215.0 300.0 171.5 L M N P 97.0 213.0 93.5 67.5 88.0 180.0 79.0 66.0 EC centrifugal, backward for clean rooms Dimensions Centrifugal blower without flange A B L 1 5,5 E N M Ø112 P EC-SYSTEMS 145 C D EC centrifugal, forward K Accessories I Technology Brass lead tips 181 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts J AC centrifugal blowers dual inlet, Ø 133 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M2E 068-DF Power input D2E 133 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 810 600 1150 1550 190 195 0.84 0.85 3.0 /450 3.0 /450 56 55 0 100 1~ 230 1~ 230 A -25 to +40 -25 to +40 subject to alterations 2 [Pa] [in H O] Curves 500 1,5 400 2 1,0 300 A 0,5 200 100 1 0 100 200 200 300 400 400 [CFM] 600 800 50 Hz 182 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1700 180 0.80 A 2 2480 138 0.61 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg D2E 133-DM47 -01 D2E 133-DM47 -23 4.4 EC centrifugal, backward for clean rooms Centrifugal blower with flange 270 254 97 1 EC-SYSTEMS 98 213 145 Ø112 67,5 5,5 102 142 126 EC centrifugal, forward 204 232 Accessories 300 Technology Brass lead tips 183 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 133 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M4E 068-BF Power input D4E 133 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: PA plastic Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 510 540 1180 1240 70 80 0.32 0.35 2.0 /400 2.0 /400 52 54 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +40 -25 to +40 subject to alterations 2 [Pa] [in H O] Curves 140 100 0,4 120 80 2 60 0,2 A 40 1 20 0 100 100 200 200 300 300 400 500 50 Hz 184 [CFM] [m3/h] 60 Hz A 1 1240 66 0.30 A 2 1380 63 0.29 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg D4E 133-AH01 -55 D4E 133-AH01 -58 2.6 EC centrifugal, backward for clean rooms Centrifugal blower with flange 254 238 88 1 5,5 76 Ø112 180 66 EC-SYSTEMS 145 69 108 92 EC centrifugal, forward 171,5 215 Accessories 300 Technology Brass lead tips 185 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 133 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 670 675 760 790 1080 1100 1230 1280 73 83 75 95 0.33 0.37 0.34 0.43 2.0 /400 2.0 /400 2.0 /450 2.0 /450 52 52 55 56 0 0 0 0 n [rpm] P1 [W] I [A] Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: PA plastic Rotor: Partially cast in aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings Nominal data Type Motor D4E 133 M4E 068-BF A D4E 133 M4E 068-CF B 1~ 1~ 1~ 1~ -25 to +40 -25 to +40 -25 to +70 -25 to +60 subject to alterations 2 [Pa] [in H O] Curves 0,6 160 0,4 120 80 2 0,2 2 A B 40 1 0 100 200 200 300 400 1 400 [CFM] 600 [m3/h] 50 Hz 186 60 Hz A 1 1150 69 0.31 A 2 1300 65 0.30 B 1 1280 67 0.30 B 2 1370 58 0.27 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE kg D4E 133-DH01 -J2 D4E 133-DH01 -J4 3.3 D4E 133-DL01 -H9 D4E 133-DL01 -J5 3.8 EC centrifugal, backward for clean rooms Centrifugal blower with flange 270 254 97 1 EC-SYSTEMS 98 213 145 Ø112 67,5 5,5 102 142 126 EC centrifugal, forward 204 232 Accessories 300 Technology Brass lead tips 187 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – AC centrifugal blowers dual inlet, Ø 146 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 935 690 970 690 1650 2100 2050 2550 245 270 300 330 1.08 1.20 1.31 1.45 6.0 /400 6.0 /400 8.0 /400 8.0/400 60 62 63 68 100 250 200 400 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings Nominal data Type Motor D2E 146 M2E 068-EC A D2E 146 M2E 068-EC B 1~ 1~ 1~ 1~ -25 to +40 -25 to +40 -25 to +40 -25 to +35 subject to alterations 2 2,5 [Pa] [in H O] Curves 500 2,0 600 400 B 2 1,5 2 300 1 1,0 A 1 0,5 200 100 0 100 200 200 300 400 400 600 500 800 600 [CFM] 1000 [m3/h] 50 Hz 188 60 Hz n [rpm] P1 [W] I [A] A 1 1935 230 1.02 A 2 2560 167 0.74 B 1 2300 262 1.15 B 2 2600 206 0.91 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST kg D2E 146-AP43 -02 D2E 146-AP43 -22 4.2 D2E 146-AP47 -02 D2E 146-AP47 -22 4.2 EC centrifugal, backward for clean rooms Centrifugal blower with flange 270 254 97 1 98 Ø117 219 69 EC-SYSTEMS 145 5,5 102 142 126 EC centrifugal, forward 206 232 Accessories 350 Technology Brass lead tips 189 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 146 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M4E 068-CF Power input D4E 146 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 835 765 1000 950 100 116 0.44 0.51 2.0 /450 2.0 /450 55 53 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +50 -25 to +50 subject to alterations 0,6 160 120 0,4 2 A 0,2 80 40 1 0 100 200 200 300 400 400 [CFM] 600 800 50 Hz 190 A 1 1180 88 0.39 A 2 1390 65 0.29 2 [Pa] [in H O] Curves [m3/h] 60 Hz A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg D4E 146-AA07 -02 D4E 146-AA07 -22 3.5 EC centrifugal, backward for clean rooms Centrifugal blower with flange 270 254 97 1 98 Ø117 219 69 EC-SYSTEMS 145 5,5 102 142 126 EC centrifugal, forward 206 232 Accessories 350 Technology Brass lead tips 191 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 160 Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection M4E 068-DF Power input D4E 160 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor mounted via brackets on one side – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 60 780 820 1200 1200 117 140 0.51 0.62 3.0 /450 3.0 /450 58 58 0 0 n [rpm] P1 [W] I [A] 1~ 230 1~ 230 A -25 to +55 -25 to +40 subject to alterations 2 [Pa] 200 0,8 240 [in H O] Curves 0,6 160 2 120 0,4 A 0,2 80 40 1 0 100 200 200 300 400 400 [CFM] 600 [m3/h] 50 Hz 192 60 Hz A 1 1230 114 0.50 A 2 1360 93 0.41 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC kg D4E 160-DA01 -02 D4E 160-DA01 -22 4.3 EC centrifugal, backward for clean rooms Centrifugal blower with flange 214 198 103 1 5,5 100,5 Ø130 242 87 EC-SYSTEMS 175 105 145 129 EC centrifugal, forward 226 176 Accessories 400 Technology Brass lead tips 193 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 160 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 50 1195 1850 410 1.80 10.0 /400 64 200 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 20 – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D2E 160 M2E 074-FA 1~ 230 A -25 to +40 subject to alterations 2 2,5 [Pa] [in H O] Curves 600 500 2,0 2 A 1,5 400 1 1,0 300 0,5 200 100 0 150 200 300 400 450 600 800 600 1000 [CFM] 1200 50 Hz 194 [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 2265 380 1.67 A 2 2520 338 1.50 A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, GOST Centrifugal blower with flange kg D2E 160-AB01 -06 — 5.7 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – EC centrifugal, forward 225 276 Technology Brass lead tips 195 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 1300 Accessories 100,5 Ø130 241 87 EC-SYSTEMS 107 17 5 102 AC centrifugal blowers dual inlet, Ø 160 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1240 1250 1310 1410 1300 1350 1350 1450 180 245 185 270 0.79 1.07 0.81 1.18 5.0 /400 5.0 /400 6.0 /400 6.0 /400 63 64 64 67 0 10 0 0 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D4E 160 M4E 068-EC A D4E 160 M4E 068-GA B 1~ 1~ 1~ 1~ -25 to +65 -25 to +30 -25 to +70 -25 to +40 subject to alterations [Pa] 2 1,0 250 [in H O] Curves 0,75 200 150 0,5 2 100 0,25 A 50 11 B 0 200 400 400 600 800 800 1200 50 Hz 196 [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] A 1 1355 153 0.67 A 2 1445 100 0.43 B 1 1400 154 0.68 B 2 1460 103 0.46 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: B CCC, GOST Options: With flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – – Centrifugal blower with flange kg I D4E 160-EG06 -05 — 4.5 232.0 D4E 160-FH12 -05 — 5.9 276.0 EC centrifugal, backward for clean rooms Dimensions Centrifugal blower without flange EC centrifugal, forward 225 I Technology Brass lead tips 197 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 400 Accessories 100,5 Ø130 241 87 EC-SYSTEMS 107 17 5 102 AC centrifugal blowers dual inlet, Ø 180 subject to alterations Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection A Current draw M4D 068-GA Power input D4D 180 (1)(2) Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 3~ 230/400 50 3~ 230/400 60 1880 1860 1050 1030 (1) data collected via exhaust duct (step diffuser, 1 m length) 290 0.92/0.53 360 1.04/0.60 — — 2 [Pa] [in H O] 1,25 200 A 0,75 250 1,00 300 2 0,50 150 0,25 100 50 1 0 200 400 198 400 600 800 800 1200 1000 1600 1200 [CFM] 2000 [m3/h] 50 Hz 60 Hz 0 0 -25 to +55 -25 to +30 n [rpm] P1 [W] I [A] (2) 230 VAC ∆ / 400 VAC Y Curves 350 62 62 A 1 1100 260 0.83/0.48 A 2 1275 175 0.56/0.32 C1)/C2) General information AC centrifugal, backward Motor protection: Without thermal protection Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Radial blower with flange (large) kg — D4D 180-CB01 -02 9.5 EC centrifugal, backward for clean rooms Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – 7 133 EC centrifugal, forward 309 255 180 296 136 224 180 Accessories 2 19 600 Brass lead tips 255 Technology 3,2 199 Guard grille p. 555 Electr. connections p. 596 f. Contacts 333 ˚ Ø149 60 EC-SYSTEMS 289 6x 278 258 5˚ AC centrifugal blowers dual inlet, Ø 180 Electr. connection subject to alterations Perm. amb. temp. B Min. back pressure M4E 068-LA Sound pressure level D4E 180 (1) 1~ 1~ 1~ 1~ Capacitor A Current draw M4E 068-LA Power input D4E 180 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1900 2040 2110 2125 1300 1360 1250 1280 360 460 380 495 1.58 2.02 1.68 2.16 10.0 /400 10.0 /400 10.0 /400 10.0 /400 65 66 64 64 0 0 0 0 n [rpm] P1 [W] I [A] (1) data collected via exhaust duct (step diffuser, length 1 m) 2 [Pa] [in H O] Curves 1,25 350 300 200 1,00 B 0,75 250 2 2 0,50 150 A 0,25 100 50 1 0 200 400 200 -25 to +65 -25 to +40 -25 to +60 -25 to +35 400 600 800 800 1200 1000 1600 1 1200 [CFM] 2000 [m3/h] 50 Hz 60 Hz A 1 1350 310 1.36 A 2 1400 240 1.07 B 1 1300 360 1.60 B 2 1385 270 1.20 A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC, A also GOST EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4E 180-BA02 -02 — 11.0 188.0 168.0 134.0 — D4E 180-CA02 -02 10.8 278.0 258.0 224.0 180.0 D 296 B S 90.0 309 255 180 Hole with large flange only 7 133 E EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – E S 136 Accessories 2 19 600 Brass lead tips 255 Technology 3,2 Ø 149 333 ˚ 201 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 60 EC-SYSTEMS 289 6x C D 5˚ AC centrifugal blowers dual inlet, Ø 200 Frequency Air flow Speed/rpm Power input Current draw Capacitor Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 3~ 230/400 50 2550 1080 480 1.54/0.89 1~ 230 1~ 230 2380 2050 1100 1250 490 525 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D4D 200 (1)(2) M4D 068-LA D4E 200 (1) A M4E 068-LA B subject to alterations 50 60 (1) data collected via exhaust duct (step diffuser, 1 m length) 2.15 2.30 — 10.0 /400 10.0 /400 2 [Pa] [in H O] 1,5 350 300 B 1,0 250 2 200 2 0,5 150 A 100 1 50 1 0 250 400 500 800 750 1200 1000 1600 1250 2000 [CFM] 2400 50 Hz 202 [m3/h] 60 Hz 0 -25 to +30 60 60 50 150 -25 to +40 -25 to +40 (2) 230 VAC ∆ / 400 VAC Y Curves 400 63 n [rpm] P1 [W] I [A] A 1 1125 425 1.36/0.79 A 2 1260 310 1.00/0.58 B 1 1185 445 1.95 B 2 1300 350 1.55 C1)/C2) A1) General information AC centrifugal, backward Motor protection: A without TOP, B TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal blower with flange (large) kg — D4D 200-CA01 -02 12.0 — D4E 200-CA02 -02 11.9 EC centrifugal, backward for clean rooms Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – 7 146 EC centrifugal, forward 341 287 180 327 151 250 180 Accessories 3 21 600 Brass lead tips 287 Technology 3,2 203 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 371 ˚ Ø 167 60 EC-SYSTEMS 321 6x 304 284 5˚ AC centrifugal blowers dual inlet, Ø 225 m3/h rpm W A D4D 225(1)(2) M4D 074-LA subject to alterations A 3~ 230/400 50 3~ 230/400 60 2980 2430 1000 1050 (1) data collected via exhaust duct (step diffuser, 1 m length) 680 1.99/1.15 700 2.17/1.25 Electr. connection Current draw Hz Perm. amb. temp. Power input Motor Min. back pressure Speed/rpm Type Sound pressure level Air flow Nominal data Capacitor Frequency VAC Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings µF/VDB dB(A) Pa °C p. 596 f. 64 62 0 100 — — (2) 230 VAC ∆ / 400 VAC Y 2 [Pa] [in H O] Curves 500 1,5 400 A 300 1,0 2 0,5 200 100 1 0 500 500 1000 1000 1500 1500 2000 2500 [CFM] 3000 50 Hz 204 [m3/h] 60 Hz -25 to +45 -25 to +35 n [rpm] P1 [W] I [A] A 1 1110 600 1.75/1.02 A 2 1300 385 1.13/0.66 C1)/C2) General information AC centrifugal, backward Motor protection: Without thermal protection Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, CE Approvals: CCC Centrifugal blower with flange (large) kg — D4D 225-CC01 -02 12.5 EC centrifugal, backward for clean rooms Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – 7 158 EC centrifugal, forward 341 287 180 327 Accessories 151 600 Brass lead tips 287 Technology 2 24 205 Guard grille p. 555 Electr. connections p. 596 f. Contacts 3,2 Ø194 370 ˚ 250 180 60 EC-SYSTEMS 321 6x 304 284 5˚ AC centrifugal blowers dual inlet, Ø 225 subject to alterations Electr. connection C Perm. amb. temp. M6E 068-LA Min. back pressure D6E 225 (1) B Sound pressure level M4E 074-LA Capacitor D4E 225 (1) A Current draw M4E 074-LA Power input D4E 225 Speed/rpm Motor Air flow Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Partially cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit) – Type of protection: A B IP 22, C IP 54 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f. 1~ 230 50 2600 1100 700 3.05 25.0 /400 67 20 -25 to +40 1~ 230 50 2650 1150 650 2.84 25.0 /400 65 100 -25 to +40 1~ 230 1~ 230 50 60 2680 2480 800 900 365 410 1.60 1.80 10.0 /450 10.0 /450 59 59 20 80 -25 to +40 -25 to +40 (1) data collected via exhaust duct (step diffuser, length 1 m) 2 [Pa] [in H O] Curves 350 300 1,0 250 2 2 B A 200 150 2 1 0,5 C 100 1 1 50 0 500 500 206 1000 1000 1500 1500 2000 [CFM] 2500 [m3/h] 50 Hz 60 Hz n [rpm] P1 [W] I [A] A 1 1200 660 2.88 A 2 1370 480 2.13 B 1 1170 680 2.98 B 2 1300 550 2.44 C 1 850 330 1.45 C 2 940 245 1.08 A1) A1) A1) General information AC centrifugal, backward Motor protection: TOP wired internally Cable exit: Variable Protection class: I Capacitor: A B FPU (P2) acc. to IEC 252 Product conforming to standards: EN 60335-1, CE Approvals: A B CCC, B GOST EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4E 225-BC01 -02 — 12.1 341.0 321.0 200.0 180.0 146.0 287.0 287.0 — D4E 225-CC01 -02 12.4 341.0 321.0 304.0 284.0 250.0 287.0 287.0 180.0 — D6E 225-FB07 -02 12.5 387.0 367.0 304.0 284.0 250.0 333.0 333.0 180.0 B 327 B C D E F I S 90.0 A F 180 Hole with large flange only 7 158 C EC centrifugal, backward for clean rooms A EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – – E S 151 Accessories 2 24 600 Brass lead tips I Technology 3,2 Ø194 370 ˚ 207 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 60 EC-SYSTEMS B 6x C D 5˚ AC centrifugal blowers dual inlet, Ø 225 B subject to alterations Electr. connection M4D 094-LA Perm. amb. temp. D4D 225 (2) 3~ 3~ 3~ 3~ Min. back pressure A Capacitor M4D 094-LA Max. current draw (1) D4D 225 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 400 Y 400 Y 400 Y 400 Y 50 60 50 60 1300 1350 1230 1360 950 1320 1140 1280 1.82 2.40 2.10 2.30 (1) Nominal data in operating point with maximum load — — — — 0 0 0 150 -40 to +85 -40 to +40 -40 to +70 -40 to +50 2 [Pa] [in H O] 1,5 400 B 300 2 1,0 2 200 1 0,5 1 100 A 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 208 [CFM] [m3/h] 60 Hz D1) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 D1) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1360 717 1.50 69 A 2 1420 454 1.18 63 B 1 1320 877 1.70 72 B 2 1390 589 1.31 65 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: A GOST Options: 400 VAC ∆/Y for two speed steps available on request, mounting brackets on request EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4D 225-FH02 -01 — 15.6 200.0 180.0 146.0 — D4D 225-GH02 -01 15.6 304.0 284.0 250.0 180.0 D 327 E B 90.0 387 333 180 Hole with large flange only 7 158 S EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – – E S 151 Accessories 2 24 600 Brass lead tips 333 Technology 3,2 Ø194 370 ˚ 209 Guard grille p. 555 Electr. connections p. 596 f. Contacts 60 EC-SYSTEMS 367 6x C D 5˚ AC centrifugal blowers dual inlet, Ø 225 B subject to alterations Electr. connection M4E 094-LA Perm. amb. temp. D4E 225 (2) 1~ 1~ 1~ 1~ Min. back pressure A Capacitor M4E 094-LA Max. current draw (1) D4E 225 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1230 1410 1230 1370 1060 1085 1060 1120 5.38 5.24 5.38 5.40 10.0 /450 10.0 /500 10.0 /450 10.0 /500 0 200 100 250 (1) Nominal data in operating point with maximum load -40 to +55 -40 to +45 -40 to +55 -40 to +45 2 [Pa] [in H O] 1,5 400 300 2 2 1,0 B 200 A 1 0,5 1 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 210 [CFM] [m3/h] 60 Hz A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 A2a) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1330 802 4.16 69 A 2 1410 530 3.08 63 B 1 1270 947 4.81 71 B 2 1380 652 3.52 65 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: A GOST Options: Mounting brackets on request EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4E 225-EH01 -01 — 16.7 200.0 180.0 146.0 — D4E 225-DH01 -01 16.7 304.0 284.0 250.0 180.0 D 327 E B 90.0 387 333 180 Hole with large flange only 7 158 S EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – – E S 151 Accessories 2 24 600 Brass lead tips 333 Technology 3,2 Ø194 370 ˚ 211 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 60 EC-SYSTEMS 367 6x C D 5˚ AC centrifugal blowers dual inlet, Ø 240 subject to alterations Min. back pressure Perm. amb. temp. Electr. connection A Capacitor M4E 094-IF Max. current draw (1) D4E 240 Max. power input (1) Motor Speed/rpm (1) Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 50 60 1300 1310 1020 1320 4.45 5.75 25.0 /400 25.0 /400 0 50 1~ 230 1~ 230 -40 to +50 -40 to +55 (1) Nominal data in operating point with maximum load 2 A 2,0 [Pa] [in H O] Curves 500 1,5 400 2 1,0 300 200 0,5 1 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 212 A2a) [CFM] [m3/h] 60 Hz n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1345 849 3.80 73 A 2 1390 692 3.10 70 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Options: Mounting brackets on request kg D4E 240-BA01 -01 — 15.3 EC centrifugal, backward for clean rooms Centrifugal blower with flange (large) 90 200 180 Accessories 151 600 Brass lead tips 287 Technology 2 24 Ø209 370 0˚ 2 3x1 EC-SYSTEMS 321 5˚ 146 7 158 EC centrifugal, forward 341 287 180 327 213 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts Centrifugal blower with flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward – – – – – AC centrifugal blowers dual inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 400 Y 400 Y 400 Y 400 Y 50 60 50 60 1240 1410 1200 1410 1140 1210 1270 1270 2.10 2.20 2.30 2.20 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D4D 250 M4D 094-LA A D4D 250 (2) M4D 094-LA B subject to alterations 3~ 3~ 3~ 3~ (1) Nominal data in operating point with maximum load — — — — 0 250 50 350 -40 to +60 -40 to +45 -40 to +45 -40 to +45 2 [Pa] [in H O] 2,0 1,5 400 2 2 B 300 1,0 A 1 1 0,5 200 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 214 [CFM] [m3/h] 60 Hz D1) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 D1) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1320 875 1.73 71 A 2 1410 481 1.21 65 B 1 1280 1001 1.89 72 B 2 1370 675 1.43 69 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Options: 400 VAC ∆/Y for two speed steps available on request, mounting brackets on request EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4D 250-BA02 -01 — 16.7 218.0 190.0 167.0 — D4D 250-CA02 -01 16.7 313.0 285.0 262.0 180.0 293.0 D 387 E B U 90.0 198.0 349 328 298 180 Hole with large flange only 7 194 S EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – E Accessories Ø 200 600 298 Technology Brass lead tips 215 Guard grille p. 555 Electr. connections p. 596 f. Contacts 173 27 5 3,2 S C U D 392 0˚ EC-SYSTEMS 329 6x6 AC centrifugal blowers dual inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 1210 1460 1200 1400 1240 1230 1250 1285 6.00 5.54 6.00 5.90 14.0 /500 14.0 /500 14.0 /500 14.0 /500 0 300 100 350 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D4E 250 M4E 094-LA A D4E 250 (2) M4E 094-LA B subject to alterations 1~ 1~ 1~ 1~ (1) Nominal data in operating point with maximum load -40 to +40 -40 to +45 -40 to +40 -40 to +40 2 [Pa] [in H O] 2,0 1,5 400 B 2 2 300 1,0 A 200 1 0,5 1 100 0 500 1000 1000 1500 2000 2000 3000 2500 4000 50 Hz 216 [CFM] [m3/h] 60 Hz A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 500 A2a) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 1320 975 4.74 71 A 2 1400 665 3.50 65 B 1 1270 1100 5.31 72 B 2 1370 788 3.94 69 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: B GOST Options: Mounting brackets on request EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D4E 250-BA01 -01 — 16.3 218.0 190.0 167.0 — D4E 250-CA01 -01 16.3 313.0 285.0 262.0 180.0 293.0 D 387 E B U 90.0 198.0 349 328 298 180 Hole with large flange only 7 194 S EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – – E Accessories Ø 200 600 298 Technology Brass lead tips 217 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 173 27 5 3,2 S C U D 392 0˚ EC-SYSTEMS 329 6x6 AC centrifugal blowers dual inlet, Ø 250 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Min. back pressure Perm. amb. temp. Electr. connection VAC Hz rpm W A µF/VDB Pa °C p. 596 f. 230 230 230 230 50 60 50 60 800 770 680 580 400 480 470 500 1.85 2.15 2.20 2.30 10.0 /400 10.0 /450 10.0 /400 10.0 /450 0 0 0 0 Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Cast in aluminium – Direction of rotation: Counter-clockwise, seen on rotor (on cable exit) – Type of protection: IP 20 (acc. to EN 60527) – Insulation class: "F" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: EW motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D6E 250 M6E 094-HA A D6E 250 (2) M6E 094-HA B subject to alterations 1~ 1~ 1~ 1~ (1) Nominal data in operating point with maximum load -40 to +80 -40 to +80 -40 to +70 -40 to +55 2 [Pa] [in H O] 1,0 200 0,75 B 2 2 0,5 150 A 100 1 0,25 1 50 0 400 400 800 800 1200 1200 1600 2000 1600 2400 2800 50 Hz 218 [CFM] [m3/h] 60 Hz A2a) (2) Data collected via exhaust duct (step diffuser, 1 m length) Curves 250 A2a) n [rpm] P1 [W] I [A] LpA [dB(A)] A 1 890 318 1.51 59 A 2 940 244 1.25 53 B 1 830 375 1.74 65 B 2 900 304 1.45 57 General information AC centrifugal, backward Motor protection: Design with thermal overload protector Cable exit: Axial Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Options: Mounting brackets on request EC centrifugal, backward Dimensions Centrifugal blower with flange Centrifugal blower with flange (large) kg D6E 250-BA01 -01 — 14.4 218.0 190.0 167.0 — D6E 250-CA01 -01 14.4 313.0 285.0 262.0 180.0 293.0 D 387 E B U 90.0 198.0 349 328 298 180 Hole with large flange only 7 194 S EC centrifugal, backward for clean rooms C EC centrifugal, forward Mass of centrifugal blower AC centrifugal, forward – – – – – E Accessories Ø 200 600 298 Technology Brass lead tips 219 Guard grille p. 555 Capacitor p. 560 f. Electr. connections p. 596 f. Contacts 173 27 5 3,2 S C U D 392 0˚ EC-SYSTEMS 329 6x6 220 General information 222 EC centrifugal fans with sheet steel impeller, 24 / 48 VDC Ø 250 - Ø 280 240 EC centrifugal fans with aluminium impeller, 24 / 48 VDC Ø 310 - Ø 400 246 EC centrifugal fans with plastic impeller, line-fed Ø 133 - Ø 250 262 EC centrifugal fans with sheet steel impeller, line-fed Ø 250 - Ø 280 296 EC centrifugal fans with aluminium impeller, line-fed Ø 310 - Ø 630 316 AC centrifugal, backward Ø 120 - Ø 250 221 Contacts Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward EC centrifugal fans with plastic impeller, 24 / 48 VDC AC centrifugal, forward EC centrifugal fans backward curved EC centrifugal fans backward curved, Ø 120 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 250 4060 26 1.20 62 -25 to +50 G) A 48 36-57 250 4060 26 0.60 62 -25 to +50 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 120 M1G 045-BE R1G 120 M1G 045-BE subject to alterations [Pa] Curves A 1,5 400 4' 300 P1 [W] LpA [dB(A)] tL [%] A 1’ 4520 36 65 — A 2’ 4500 36 64 27 A 3’ 4540 36 61 45 A 4’ 4750 32 64 39 A 1 4060 26 62 — A 2 4000 26 61 27 A 3 4050 26 58 45 A 4 4200 23 61 39 A 5 3270 14 56 — A 6 3250 14 55 27 A 7 3280 14 53 45 A 8 3400 13 56 39 1,0 4 3' UR 200 3 0,5 8 UN 7 100 2' 2 6 5 0 25 40 222 n [rpm] 50 80 75 120 100 160 1 125 200 240 1' [CFM] General information • Tach output • Reverse polarity and locked-rotor protection AC centrifugal, backward Technical features: Control input 0-10 VDC / PWM Cable exit: Axial Protection class: I Product conforming to standard: EN 60950-1 Approvals: A (48 VDC) CCC 0.5 96120-2-4013 R1G 120-AD11 -02 0.5 96120-2-4013 54 ±1 45,3 ±0,5 18 Depth of screw max. 4 mm M4 47 16 EC centrifugal, forward R1G 120-AD13 -02 15 Inlet nozzle (long) 0, kg ± Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward – • – – – – 17 EC-SYSTEMS 6 60 300 ±20 Ø146 Ø96 -1 Ø 59 Ø 98 Ø 120 Brass lead tips 4x90˚ Technology Accessories 2 223 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 26 40,5 EC centrifugal fans backward curved, Ø 133 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 360 3900 28 1.30 63 -25 to +60 G) A 48 36-57 360 3900 28 0.70 63 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 133 M1G 055-BD R1G 133 M1G 055-BD subject to alterations 2 [Pa] [in H O] Curves A 500 1,5 400 UR 4' UN 300 4 1,0 3' 200 7 0,5 12 2' 2 11 100 6 10 9 0 50 100 100 224 5 150 200 1 200 300 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 4450 39 74 — A 2’ 4250 44 60 45 A 3’ 4270 44 59 56 A 4’ 4380 41 61 44 A 1 3900 28 63 — A 2 3770 31 58 45 A 3 3770 31 56 56 A 4 3850 29 58 44 A 5 3500 20 59 — A 6 3380 23 55 45 A 7 3400 23 53 56 A 8 3450 21 55 44 A 9 2970 13 55 — A 10 2860 15 51 45 A 11 2880 15 49 56 A 12 2930 14 51 44 8 3 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R1G 133-AA17 -02 0.7 09566-2-4013 R1G 133-AA65 -02 0.7 09566-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC 91±1 Ø 58 ±0,15 13 8 EC centrifugal, forward 55,3 ±0,6 EC-SYSTEMS 29 Ø129 6 85 450 +20 M4 Depth of screw max. 6 mm Accessories 2 Technology 41 60,6 225 Inlet nozzle p. 550 Electr. connection p. 600 Contacts Ø 87 Ø133 Ø72 Ø92,8 Brass lead tips EC centrifugal fans backward curved, Ø 175 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 565 3100 34 1.60 65 -25 to +60 G) A 48 36-57 565 3100 34 1.00 65 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 175 M1G 055-BD R1G 175 M1G 055-BD subject to alterations A 2 [Pa] [in H O] Curves 1,5 400 4' UR 300 4 1,0 UN 3' 3 200 8 0,5 7 2' 12 2 100 11 6 10 9 0 100 100 226 5 200 200 300 1 1' 300 400 500 [CFM] 600 [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 3390 46 67 — A 2’ 3200 51 60 49 A 3’ 3170 51 58 58 A 4’ 3300 51 66 39 A 1 3100 34 65 — A 2 2910 39 58 49 A 3 2880 39 56 58 A 4 3010 37 64 39 A 5 2520 20 60 — A 6 2430 22 54 51 A 7 2390 23 51 58 A 8 2470 21 60 39 A 9 2050 12 56 — A 10 1950 13 50 51 A 11 1920 13 56 58 A 12 1990 12 53 40 General information Centrifugal fan kg Inlet nozzle (long) R1G 175-AB63 -02 0.7 09576-2-4013 R1G 175-AB41 -02 0.7 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with VDE, CCC 69 ±1 14 58 ±0,15 EC centrifugal, forward 55,3 ±1 29 6 EC-SYSTEMS Ø125,5 Ø175 Ø131 Ø72 Ø170 10 Brass lead tips M4 85 450 ±20 Depth of screw max. 6 mm Accessories 2 Technology 62 227 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 42 EC centrifugal fan backward curved, Ø 175 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M1G 055-CF Power input R1G 175 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black, with cooling holes – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-52 695 4000 75 1.75 72 -25 to +40 G) subject to alterations 2 A 2,5 [Pa] [in H O] Curves 2,0 500 4' 4 1,5 400 UN 3' 8 3 1,0 300 200 7 2' 0,5 2 6 100 5 0 100 100 228 200 200 300 1 300 400 500 1' [CFM] 600 700 [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 4250 88 73 — A 2’ 4130 93 71 39 A 3’ 4050 96 67 55 A 4’ 4130 93 72 43 A 1 4000 75 72 — A 2 3920 80 69 39 A 3 3880 83 66 55 A 4 3920 80 71 43 A 5 3290 42 67 — A 6 3250 45 64 39 A 7 3160 47 62 55 A 8 3250 46 66 43 600 U52V n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R1G 175-AF29 -04 1.0 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: CCC 69 ±1 14 58 ±0,15 EC centrifugal, forward 67 ±1 29 6 EC-SYSTEMS Ø125,5 Ø175 Ø131 Ø72 Ø170 10 Brass lead tips M4 85 450 ±20 Depth of screw max. 6 mm Accessories 2 Technology 62 229 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 42 EC centrifugal fans backward curved, Ø 190 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 620 2950 51 2.30 68 -25 to +40 G) A 48 36-57 620 2950 51 1.20 68 -25 to +40 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: A (24 VDC) IP 20, A (48 VDC) IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 190 M1G 055-CF R1G 190 M1G 055-CF subject to alterations 2 [Pa] 500 A 2,0 600 [in H O] Curves 4' 1,5 400 UR 4 300 3' 1,0 UN 3 8 200 2' 0,5 7 2 100 6 0 100 100 230 5 300 200 200 300 400 500 1 600 1' 400 700 [CFM] [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 3300 71 70 — A 2’ 3200 75 66 45 A 3’ 3160 77 63 53 A 4’ 3290 72 67 42 A 1 2950 51 68 — A 2 2870 54 63 45 A 3 2830 56 60 53 A 4 2940 51 63 42 A 5 2390 28 62 — A 6 2340 30 58 45 A 7 2320 31 54 53 A 8 2390 28 58 42 General information Centrifugal fan kg Inlet nozzle (long) R1G 190-AB27 -02 1.0 09576-2-4013 R1G 190-AB25 -02 1.0 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC 68,5 ±1 Ø58 ±0,15 14 EC centrifugal, forward 67 ±0,6 EC-SYSTEMS 29 Ø125,5 max. Ø190 min. Ø131 Ø72 Ø170 10 Brass lead tips 6 85 M4 2 Depth of screw max. 6 mm Accessories min. 44,3 Technology max. 62,8 231 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 450 +20 EC centrifugal fans backward curved, Ø 190 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 560 3250 80 3.70 68 -25 to +60 G) A 48 36-57 545 3200 71 1.65 68 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 190 M1G 074-BF R1G 190 M1G 074-BF subject to alterations A 2 [Pa] [in H O] Curves (established at 24 VDC) 2,5 700 600 4' 2,0 500 UR n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 3580 106 71 — A 2’ 3590 105 66 41 A 3’ 3630 103 65 45 A 4’ 3770 97 69 33 A 1 3250 80 68 — A 2 3275 80 64 42 A 3 3300 79 63 45 A 4 3400 74 66 34 A 5 2700 47 65 — A 6 2710 47 59 41 A 7 2740 45 58 44 A 8 2795 42 61 33 A 9 1910 19 60 — A 10 1910 20 51 39 A 11 1940 19 49 43 A 12 1985 18 52 33 4 3' 1,5 400 3 UN 8 300 1,0 2' 2 7 200 6 0,5 12 11 100 10 0 50 100 232 100 9 200 150 200 300 5 250 400 1 300 500 1' [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) R1G 190-AC37 -52 1.3 09576-2-4013 R1G 190-AC11 -52 1.3 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC 68,5 ±1 Ø58 ±0,15 14 EC centrifugal, forward 65 ±1 EC-SYSTEMS 32,7 Ø125,5 max. Ø190 min. Ø131 Ø92 Ø170 10 Brass lead tips 6 85 M4 2 Depth of screw max. 6 mm Accessories min. 44,6 Technology max. 62,8 233 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 450 +20 EC centrifugal fans backward curved, Ø 220 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 1055 3150 106 5.00 76 -25 to +60 G) A 48 36-57 1015 3100 100 2.40 73 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 220 M1G 074-BF R1G 220 M1G 074-BF subject to alterations A 2 [Pa] [in H O] Curves (established at 24 VDC) 3,0 800 700 500 2,0 600 UR 4' 4 3' 300 1,0 3 8 2' 200 2 7 6 100 0 200 200 234 400 400 600 5 800 600 1000 1 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 3400 128 78 — A 2’ 3200 132 69 53 A 3’ 3050 135 67 55 A 4’ 3000 137 71 46 A 1 3150 106 76 — A 2 3010 110 68 53 A 3 2870 112 65 55 A 4 2800 113 69 46 A 5 2470 50 70 — A 6 2360 54 63 53 A 7 2300 57 59 55 A 8 2250 59 63 46 UN 400 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R1G 220-AB35 -52 1.4 09609-2-4013 R1G 220-AB73 -52 1.4 09609-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC 71±1 Ø58 ±0,15 21 EC centrifugal, forward 65 ±1 EC-SYSTEMS 32,7 Ø252 Ø155 min. Ø160,7 Ø92 max. Ø220,9 22 Brass lead tips 6 85 M4 2 Depth of screw max. 6 mm Accessories min. 44 Technology max. 64 235 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 450 +20 EC centrifugal fans backward curved, Ø 225 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 1125 2600 100 4.60 67 -25 to +60 G) A 48 36-57 1130 2700 95 2.20 67 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 225 M1G 074-BF R1G 225 M1G 074-BF subject to alterations A 2 [Pa] [in H O] Curves (established at 48 VDC) 700 500 2,0 600 4' 4 300 8 3' 1,0 UN 3 200 7 2' 2 6 100 5 0 200 200 236 400 400 600 800 1 1' 600 [CFM] 1000 [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 2780 112 69 — A 2’ 2610 116 64 48 A 3’ 2570 117 62 57 A 4’ 2780 112 66 42 A 1 2700 95 67 — A 2 2450 93 63 48 A 3 2400 94 60 57 A 4 2610 91 64 42 A 5 2230 59 63 — A 6 2150 63 58 48 A 7 2100 64 56 57 A 8 2230 58 58 42 UR 400 n [rpm] General information kg Inlet nozzle (long) R1G 225-AF07 -52 1.5 96358-2-4013 R1G 225-AF11 -52 1.5 96358-2-4013 99±1 65±1 Ø58±0,15 28 EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC M4 2 EC-SYSTEMS Depth of screw max. 6 mm Accessories max. 89,4 Technology min. 62 237 Inlet nozzle p. 550 Electr. connection p. 600 Contacts 450 +20 32,7 Ø146 Ø92 min. Ø153 max. Ø225,3 6 85 Ø223 25 Brass lead tips EC centrifugal fans backward curved, Ø 250 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 1140 2540 93 4.30 73 -25 to +60 G) A 48 36-57 1200 2600 105 2.55 72 -25 to +60 G) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 250 M1G 074-CF R1G 250 M1G 074-CF subject to alterations A 2 [Pa] [in H O] Curves (established at 48 VDC) 700 500 2,0 600 400 4 3' 300 8 3 1,0 UN 200 7 2' 2 6 100 0 200 200 238 5 600 400 400 600 800 1000 1 1' [CFM] 1200 [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 2870 134 75 — A 2’ 2610 139 68 55 A 3’ 2530 140 63 58 A 4’ 2650 138 66 48 A 1 2600 105 72 — A 2 2440 114 66 55 A 3 2360 116 62 58 A 4 2490 112 64 48 A 5 2190 59 68 — A 6 2020 67 62 55 A 7 2020 70 57 58 A 8 2070 66 59 48 UR 4' n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R1G 250-AQ21 -52 2.0 96359-2-4013 R1G 250-AQ37 -52 2.0 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC EC-SYSTEMS 31 Ø255 Ø164,5 max. Ø250,2 Ø92 min. Ø172 6 85 58 ±0,15 28 75 ±1 Brass lead tips EC centrifugal, forward 31 89 ±1 M4 450+20 Depth of screw max. 6 mm Accessories 2 Technology max. 74,3 239 Inlet nozzle p. 550 Electr. connection p. 600 Contacts min. 44,5 EC centrifugal fan backward curved, Ø 250 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 1580 2645 135 2.80 72 -25 to +60 G) Curve Nominal voltage – Material: Impeller: Sheet steel Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 250 M3G 084-CA A subject to alterations A 2 [Pa] [in H O] Curves 800 3,0 UR 2,5 700 600 4' 500 2,0 UN 4 1,5 400 3' 3 1,0 300 8 2' 200 7 0,5 2 100 6 12 0 11 10 200 400 240 9 5 400 800 1' 1 600 800 1200 1000 1600 [CFM] [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 3055 207 75 — A 2’ 2990 256 70 45 A 3’ 2970 274 68 60 A 4’ 2980 270 71 55 A 1 2645 135 72 — A 2 2600 166 67 45 A 3 2580 182 64 60 A 4 2590 177 66 55 A 5 1900 56 66 — A 6 1875 69 59 45 A 7 1870 73 56 60 A 8 1870 72 58 55 A 9 835 9 48 — A 10 830 10 44 45 A 11 830 11 43 60 A 12 830 10 35 55 General information Inlet nozzle (long) R3G 250-AD62 -30 3.0 96359-2-4013 Depth of screw 12-14 mm 106,5 ±1,8 77 ±1 EC centrifugal, forward kg 31 ±0 90 ,1 5 EC-SYSTEMS 34 Ø255 Ø164,5 Ø102 Ø172 Ø252 28 0 +2 0 60 85 M5 8 Accessories 2 Technology Core-end sleeves min. 55,7 max. 85,2 241 Inlet nozzle p. 550 Electr. connection p. 600 Contacts Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC EC centrifugal fans backward curved, Ø 280 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 1750 1710 95 4.60 71 -25 to +60 G) A 48 36-57 1750 1710 95 2.30 71 -25 to +60 G) Curve Nominal voltage – Material: Impeller: Sheet steel Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 280 M1G 074-CF R1G 280 M1G 074-CF subject to alterations A 2 [Pa] [in H O] Curves 500 P1 [W] LpA [dB(A)] tL [%] A 1’ 1840 118 72 — A 2’ 1650 127 64 55 A 3’ 1670 126 62 55 A 4’ 1950 114 67 31 A 1 1710 95 71 — A 2 1550 100 63 55 A 3 1560 100 59 55 A 4 1810 91 64 31 A 5 1470 60 67 — A 6 1360 68 60 55 A 7 1370 67 55 55 A 8 1530 56 59 31 1,5 400 n [rpm] 4' UR 300 1,0 4 3' UN 8 200 3 0,5 7 2' 100 2 6 5 0 200 400 242 400 600 800 800 1200 1 1000 1600 1' [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) R1G 280-AE45 -52 2.8 96360-2-4013 R1G 280-AE47 -52 2.8 96360-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC EC-SYSTEMS 31 Ø280 Ø182,5 max. Ø281,5 Ø92 min. Ø190,2 6 85 58 ±0,15 31 75 ±1 Brass lead tips EC centrifugal, forward 35 125 ±1 M4 450 +20 Accessories Depth of screw max. 6 mm Technology 2 243 Inlet nozzle p. 550 Electr. connection p. 600 Contacts min. 79,7 max. 112,5 EC centrifugal fan backward curved, Ø 280 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-CA Power input R3G 280 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet steel Rotor: Coated in black – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 2020 1965 123 2.60 70 -25 to +60 G) subject to alterations 2 [Pa] 1,5 400 UN 300 1,0 3 200 8 2 0,5 7 100 6 12 11 10 5 9 400 244 tL [%] 1’ 2265 187 72 — 2’ 2185 243 68 53 A 3’ 2165 258 65 60 A 4’ 2230 213 69 50 A 1 1965 123 70 — A 2 1905 160 65 53 A 3 1885 171 61 60 A 4 1940 140 66 50 A 5 1390 46 63 — A 6 1365 61 58 53 A 7 1360 65 53 60 A 8 1380 53 55 50 A 9 800 12 53 — A 10 790 15 48 53 A 11 785 15 42 60 A 12 795 13 41 50 2' 200 LpA [dB(A)] 3' 4 0 P1 [W] A UR 4' n [rpm] A A 2,0 500 [in H O] Curves 400 600 800 800 1200 1000 1600 1 1200 2000 1' [CFM] [m3/h] General information Inlet nozzle (long) R3G 280-AC66 -30 3.3 96360-2-4013 Depth of screw 12-14 mm 121±1,8 77±1 EC centrifugal, forward kg 35 5 ,1 ±0 90 EC-SYSTEMS 34 Ø280 Ø182,5 Ø191 Ø102 0 Ø281 31 +2 0 60 85 M5 8 2 Accessories min. 79,7 max. 112,5 Technology Core-end sleeves 245 Inlet nozzle p. 550 Electr. connection p. 600 Contacts Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA EC centrifugal fans backward curved, 3-D, Ø 310 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 A 24 16-28 1910 1600 90 4.20 64 -25 to +45 G) A 48 36-57 1910 1600 90 2.20 64 -25 to +45 G) Curve Nominal voltage – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R1G 310 M1G 074-CF R1G 310 M1G 074-CF subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 500 300 1,0 4' UR 4 3' 200 8 UN 3 0,5 7 2' 100 2 6 0 200 400 246 400 600 800 800 1200 5 1000 1600 1 1' 1200 2000 [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 1720 113 66 — A 2’ 1540 122 60 62 A 3’ 1490 124 59 67 A 4’ 1560 121 63 50 A 1 1600 90 64 — A 2 1430 96 58 62 A 3 1390 99 58 67 A 4 1450 96 61 50 A 5 1150 69 60 — A 6 1260 65 55 62 A 7 1230 67 54 67 A 8 1270 65 58 50 1,5 400 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R1G 310-AD19 -52 2.6 31050-2-4013 31051-2-4013 R1G 310-AD33 -52 2.6 31050-2-4013 31051-2-4013 Inlet nozzle (long) 120 ±1 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, A (48 VDC) with CCC Depth of screw max. 6 mm EC centrifugal, forward 48 18 5 ,1 ±0 31 EC-SYSTEMS 58 M4 Ø300 Ø211 Ø208,1 max. Ø318,5 min. Ø220 Ø92 Brass lead tips 55,5 35 75 ±1 6 4x90˚ 85 2 Technology max. 110,5 247 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts min. 69,5 Accessories 600 +20 EC centrifugal fan backward curved, 3-D, Ø 310 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M1G 074-CF Power input R1G 310 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-52 2100 1800 120 3.00 67 -25 to +40 G) subject to alterations 2 [Pa] 1,5 400 4' 300 1,0 4 8 UN 3' 200 U52 V 3 0,5 7 100 2 2' 6 5 0 400 400 248 800 800 1200 1600 1 1200 2000 1' [CFM] [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 1895 130 67 — A 2’ 1720 140 64 59 A 3’ 1610 147 60 67 A 4’ 1635 146 65 48 A 1 1800 120 67 — A 2 1610 118 62 59 A 3 1530 122 58 67 A 4 1570 120 63 48 A 5 1570 74 63 — A 6 1430 80 58 59 A 7 1350 82 54 67 A 8 1400 80 60 48 A 2,0 500 [in H O] Curves (established with long inlet nozzle) General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R1G 310-AD17 -11 2.6 31050-2-4013 31051-2-4013 Inlet nozzle (long) 120 ±1 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC Depth of screw max. 6 mm EC centrifugal, forward 48 18 5 ,1 ±0 31 EC-SYSTEMS 58 M4 Ø300 Ø211 Ø208,1 max. Ø318,5 min. Ø220 Ø92 Brass lead tips 55,5 35 75 ±1 6 4x90˚ 85 2 Technology max. 110,5 249 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts min. 69,5 Accessories 700 +20 EC centrifugal fan backward curved, 3-D, Ø 310 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-FA Power input R3G 310 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 2230 2000 190 4.00 71 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 3,0 800 2,5 700 4' 600 UR 500 2,0 UN 4 1,0 300 8 2' 200 2 0,5 7 100 12 6 11 10 9 0 600 250 5 400 1 800 1200 1' [CFM] 1200 1800 2400 [m3/h] LpA [dB(A)] tL [%] 1’ 2395 271 74 — A 2’ 2345 325 71 47 A 3’ 2320 362 70 60 A 4’ 2330 350 74 54 A 1 2070 178 71 — A 2 2035 211 67 47 A 3 2015 234 65 60 A 4 2025 227 70 54 A 5 1445 66 61 — A 6 1430 79 59 47 A 7 1420 88 57 60 A 8 1420 85 62 54 A 9 930 23 50 — A 10 925 26 48 47 A 11 920 29 47 60 A 12 920 28 51 54 3' 3 P1 [W] A 1,5 400 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 310-AN12 -30 4.2 31050-2-4013 31051-2-4013 Inlet nozzle (long) EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 251 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 310 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-FA Power input R3G 310 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 2620 1930 208 4.35 69 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 600 2,4 700 4' UR UN 1,8 500 3' 4 400 3 1,2 300 2' 200 0,6 8 100 6 12 11 10 5 9 0 400 800 1000 252 1200 2000 1 1600 1' 2000 3000 [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 2230 317 72 — A 2’ 2190 373 69 50 A 3’ 2150 415 66 66 A 4’ 2175 390 67 63 A 1 1930 208 69 — A 2 1900 248 65 50 A 3 1870 274 62 66 A 4 1890 257 61 63 A 5 1290 69 59 — A 6 1280 80 57 50 A 7 1270 90 55 66 A 8 1280 85 54 63 A 9 660 14 47 — A 10 660 15 46 50 A 11 655 17 44 66 A 12 655 16 44 63 2 7 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 310-AL09 -30 4.4 31050-2-4013 31051-2-4013 Inlet nozzle (long) EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 253 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts Technology Accessories Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 355 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-FA Power input R3G 355 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 2790 1560 178 3.70 69 -25 to +60 G) subject to alterations A 2 [Pa] 2,5 [in H O] Curves (established with long inlet nozzle) 600 4' UR 2,0 500 400 1,5 4 3' UN 300 P1 [W] LpA [dB(A)] tL [%] A 1’ 1800 272 73 — A 2’ 1740 333 67 53 A 3’ 1725 355 67 65 A 4’ 1770 307 70 49 A 1 1560 178 69 — A 2 1515 220 63 53 A 3 1500 236 63 65 A 4 1530 208 65 49 A 5 1088 64 60 — A 6 1065 79 56 53 A 7 1055 85 54 65 A 8 1070 75 56 49 A 9 470 9 44 — A 10 450 10 42 53 A 11 450 11 40 65 A 12 455 10 40 49 1,0 3 n [rpm] 2' 200 8 2 0,5 7 100 6 12 0 11 10 9 500 1000 254 1 5 1000 1' 1500 2000 2000 3000 [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 355-AM08 -30 4.6 35560-2-4013 35561-2-4013 Inlet nozzle (long) EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 255 Inlet nozzle p. 550 Electr. connection p. 600 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 355 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 3030 1410 168 3.50 66 -25 to +60 G) Curve Nominal voltage – Material: Impeller: Sheet aluminium, laser-welded Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 355 M3G 084-FA A subject to alterations 2 [Pa] 4' 1,5 400 UR 300 1,0 3 UN 2' 8 2 0,5 7 100 6 12 11 10 500 1000 256 1 5 9 0 P1 [W] LpA [dB(A)] tL [%] 1’ 1630 257 70 — A 2’ 1575 317 64 62 A 3’ 1570 321 63 66 A 4’ 1610 270 67 47 A 1 1410 168 66 — A 2 1370 207 60 62 A 3 1365 212 59 66 A 4 1400 177 63 47 A 5 1065 75 58 — A 6 1045 93 55 62 A 7 1040 96 55 66 A 8 1060 79 56 47 A 9 485 11 37 — A 10 480 12 35 62 A 11 480 13 34 66 A 12 480 11 35 47 3' 4 200 n [rpm] A A 2,0 500 [in H O] Curves (established with long inlet nozzle) 1000 1500 2000 3000 1' 2000 [CFM] 4000 [m3/h] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 355-AN18 -30 4.8 35560-2-4013 35561-2-4013 Inlet nozzle (long) EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 257 Inlet nozzle p. 550 Electr. connection p. 600 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 400 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-FA Power input R3G 400 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 3000 1290 200 4.20 65 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 1,5 400 4 3' UN 300 1,0 3 200 8 0,5 2' 7 2 100 12 6 11 10 0 1000 258 1 5 9 500 1000 1500 2000 3000 1' 2000 [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 1480 307 69 — A 2’ 1450 340 68 44 A 3’ 1440 353 62 68 A 4’ 1480 309 67 55 A 1 1290 200 65 — A 2 1270 224 64 44 A 3 1260 234 59 68 A 4 1285 204 62 55 A 5 850 59 56 — A 6 840 67 54 44 A 7 835 71 51 68 A 8 850 62 53 55 A 9 435 11 43 — A 10 435 12 41 44 A 11 430 13 38 68 A 12 435 12 39 55 4' UR n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 400-AD20 -30 5.0 54476-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 259 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 400 Sound pressure level Perm. amb. temp. Electr. connection A Current draw M3G 084-FA Power input R3G 400 Speed/rpm Motor Air flow Type Voltage range Nominal data Nominal voltage Curve – Material: Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VDC VDC m3/h rpm W A dB(A) °C p. 600 48 36-57 3300 1160 192 3.90 63 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 500 4' 1,5 400 UR 4 1,0 3 0,5 2 7 100 6 12 11 10 5 9 0 500 1000 260 1000 1 2000 1500 2000 3000 1' [CFM] [m3/h] tL [%] 1’ 1325 287 69 — 2’ 1300 340 66 43 A 3’ 1300 335 64 62 A 4’ 1345 268 68 53 A 1 1160 192 63 — A 2 1140 227 62 43 A 3 1140 210 59 62 A 4 1170 177 63 53 A 5 795 62 57 — A 6 784 74 56 43 A 7 780 69 56 62 A 8 795 59 56 53 A 9 500 15 49 — A 10 500 19 48 43 A 11 500 21 48 62 A 12 505 18 49 53 200 2' LpA [dB(A)] A UN 8 P1 [W] A 3' 300 n [rpm] General information Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Over-temperature protected motor • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection • Tach output – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC R3G 400-AC13 -30 kg 5.3 Inlet nozzle (long) EC centrifugal, backward for clean rooms Centrifugal fan 54476-2-4013 EC-SYSTEMS EC centrifugal, forward Depth of screw 12-14 mm 261 Inlet nozzle p. 550 Guard grille p. 553 Electr. connection p. 600 Contacts Technology Accessories Core-end sleeves EC centrifugal fan backward curved, Ø 133 Electr. connection A Perm. amb. temp. M3G 055-BD Max. current draw(1) R3G 133 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 601 50/60 4350 50 0.80 -25 to +60 H1) 1~ 115 (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 4 8 1,0 300 3 12 200 0,5 6 2 15 10 14 13 0 50 100 262 100 9 150 200 5 200 300 400 1 250 [CFM] [m3/h] tL [%] 4350 37 0.55 75 — 4310 41 0.60 74 39 A 3 4260 46 0.70 61 61 A 4 4340 41 0.60 60 45 A 5 4150 34 0.60 78 — A 6 4090 36 0.60 69 31 A 7 4010 39 0.60 58 52 A 8 4080 34 0.60 58 47 A 9 3390 20 0.40 67 — A 10 3350 22 0.40 58 30 A 11 3300 23 0.40 53 53 A 12 3350 22 0.40 53 46 A 13 2370 10 0.20 52 — A 14 2360 11 0.20 49 30 A 15 2350 11 0.20 45 56 A 16 2370 11 0.20 44 46 7 16 LpA [dB(A)] 2 11 100 I [A] 1 1,5 400 P1 [W] A A 500 n [rpm] A 2 [Pa] [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 133-AE17 -02 1.0 09566-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 263 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 133 Electr. connection A Perm. amb. temp. M3G 055-BD Max. current draw(1) R3G 133 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 601 50/60 4480 52 0.40 -25 to +60 H1) 1~ 230 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 4 8 1,0 300 3 12 200 0,5 6 2 15 10 14 13 0 50 100 264 100 9 150 200 5 200 300 400 1 250 [CFM] [m3/h] tL [%] 4480 43 0.30 75 — 4450 46 0.35 74 31 A 3 4390 49 0.40 61 51 A 4 4460 45 0.35 60 46 A 5 4150 34 0.30 78 — A 6 4090 36 0.30 69 31 A 7 4010 39 0.30 58 52 A 8 4080 34 0.30 58 47 A 9 3390 20 0.20 67 — A 10 3350 22 0.20 58 30 A 11 3300 23 0.20 53 53 A 12 3350 22 0.20 53 46 A 13 2370 10 0.10 52 — A 14 2360 11 0.10 49 30 A 15 2350 11 0.10 45 56 A 16 2370 11 0.10 44 46 7 16 LpA [dB(A)] 2 11 100 I [A] 1 1,5 400 P1 [W] A A 500 n [rpm] A 2 [Pa] [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 133-AE07 -02 1.0 09566-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 265 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 175 Perm. amb. temp. Electr. connection M3G 055-CF Max. current draw(1) R3G 175 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 601 50/60 3970 90 1.30 -25 to +60 H1) 1~ 115 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] 500 A 2,0 600 [in H O] Curves 1,5 400 P1 [W] I [A] LpA [dB(A)] tL [%] A 1 3970 72 1.10 72 — A 2 3870 81 1.20 67 45 A 3 3810 85 1.20 66 57 A 4 3790 88 1.30 65 52 A 5 3180 38 0.60 65 — A 6 3110 45 0.70 61 39 A 7 3120 46 0.70 58 53 A 8 3110 47 0.70 56 51 A 9 2270 17 0.30 59 — A 10 2240 20 0.35 54 38 A 11 2240 20 0.35 50 51 A 12 2240 21 0.35 50 50 A 13 1310 6 0.10 45 — A 14 1295 7 0.10 40 40 A 15 1285 7 0.10 37 53 A 16 1290 7 0.10 35 54 4 300 1,0 3 8 200 0,5 7 2 12 6 100 11 16 10 15 14 13 0 9 100 100 266 n [rpm] 200 200 300 1 5 300 400 500 400 600 700 [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) R3G 175-AF25 -02 1.2 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 267 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 175 Frequency Speed/rpm Max. power input(1) Max. current draw(1) Perm. amb. temp. Electr. connection VAC Hz rpm W A °C p. 601 50/60 4460 120 1.00 -25 to +60 H1) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 175 M3G 055-CF 1~ 230 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 2,5 500 2,0 600 4 1,5 400 8 3 1,0 300 7 12 2 200 0,5 11 10 15 14 13 0 100 200 268 9 5 400 300 200 400 600 1 [CFM] 800 [m3/h] I [A] LpA [dB(A)] tL [%] 1 4460 100 0.75 76 — A 2 4350 112 0.80 69 57 A 3 4300 115 0.85 66 68 A 4 4260 118 0.85 68 60 A 5 3800 65 0.50 71 — A 6 3730 72 0.55 65 56 A 7 3710 76 0.55 74 66 A 8 3710 78 0.60 64 60 A 9 3110 37 0.30 66 — A 10 3070 42 0.30 60 51 A 11 3060 44 0.35 58 61 A 12 3040 45 0.35 59 58 A 13 2170 17 0.15 59 — A 14 2150 18 0.15 54 40 A 15 2150 18 0.15 50 51 A 16 2130 19 0.15 50 48 6 16 100 P1 [W] A A 700 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 175-AF19 -02 1.2 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 269 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 190 Perm. amb. temp. Electr. connection M3G 055-CF Max. current draw(1) R3G 190 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 601 50/60 3370 87 1.40 -25 to +60 H1) 1~ 115 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] 500 A 2,0 600 [in H O] Curves 1,5 400 4 300 1,0 3 8 200 7 0,5 2 12 100 11 16 6 10 15 14 13 0 100 100 270 200 9 200 300 5 300 400 500 400 600 700 1 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 3370 76 1.10 70 — A 2 3250 81 1.20 64 44 A 3 3220 84 1.20 63 55 A 4 3190 85 1.30 60 55 A 5 2715 42 0.70 64 — A 6 2690 46 0.70 63 43 A 7 2670 48 0.80 58 54 A 8 2655 49 0.80 56 56 A 9 2310 27 0.40 61 — A 10 2285 29 0.50 56 42 A 11 2265 31 0.50 55 52 A 12 2260 32 0.50 52 53 A 13 1780 15 0.20 58 — A 14 1760 16 0.30 52 35 A 15 1750 17 0.30 48 43 A 16 1745 17 0.30 45 44 General information Centrifugal fan kg Inlet nozzle (long) R3G 190-AB15 -02 1.3 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 271 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 190 Frequency Speed/rpm Max. power input(1) Max. current draw(1) Perm. amb. temp. Electr. connection VAC Hz rpm W A °C p. 601 50/60 3570 105 0.90 -25 to +60 H1) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 190 M3G 055-CF 1~ 230 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 1,5 400 4 1,0 300 200 12 7 0,5 2 11 16 6 10 15 14 13 0 100 100 272 300 9 5 300 200 200 I [A] LpA [dB(A)] tL [%] 1 3570 90 0.65 72 — A 2 3490 96 0.70 66 47 A 3 3440 101 0.75 64 57 A 4 3410 102 0.75 62 59 A 5 2950 51 0.40 65 — A 6 2880 55 0.40 62 44 A 7 2860 58 0.45 60 55 A 8 2840 60 0.45 57 58 A 9 2510 33 0.25 62 — A 10 2480 36 0.30 58 43 A 11 2470 39 0.30 57 53 A 12 2450 40 0.30 54 56 A 13 1940 18 0.15 57 — A 14 1920 19 0.15 54 37 A 15 1900 20 0.15 51 46 A 16 1890 22 0.15 47 48 3 8 100 P1 [W] A A 600 n [rpm] 400 500 1 400 600 700 [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) R3G 190-AB23 -02 1.3 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 273 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 190 Perm. amb. temp. Electr. connection M3G 074-BF Max. current draw(1) R3G 190 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 3960 170 2.50 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 2,5 700 4 500 2,0 600 8 3 1,5 400 12 7 1,0 300 200 11 2 0,5 16 100 6 15 10 14 13 0 100 200 274 9 5 300 200 400 1 400 600 [CFM] 800 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 3960 146 1.80 73 — A 2 3940 149 1.90 71 32 A 3 3900 156 2.00 68 48 A 4 4000 147 1.90 69 43 A 5 3430 94 1.20 70 — A 6 3370 95 1.30 66 31 A 7 3310 99 1.30 64 47 A 8 3420 95 1.30 64 41 A 9 2830 58 0.80 64 — A 10 2790 59 0.80 62 28 A 11 2720 58 0.80 58 45 A 12 2830 57 0.80 60 39 A 13 1960 24 0.40 58 — A 14 1950 25 0.40 56 23 A 15 1910 25 0.40 50 37 A 16 1940 24 0.40 50 31 A 800 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 190-AF60 -01 1.8 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 275 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 190 Perm. amb. temp. Electr. connection M3G 074-BF Max. current draw(1) R3G 190 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 4050 156 1.15 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 3,0 700 4 500 2,0 600 8 3 400 12 1,0 11 200 2 16 6 15 10 14 13 0 100 200 276 I [A] LpA [dB(A)] tL [%] 1 4050 149 1.10 74 — A 2 4040 156 1.10 72 35 A 3 4010 155 1.10 69 52 A 4 4090 142 1.00 69 43 A 5 3490 101 0.70 70 — A 6 3460 104 0.70 68 33 A 7 3250 103 0.70 65 51 A 8 3535 96 0.70 65 41 A 9 2925 62 0.50 66 — A 10 2915 63 0.50 64 33 A 11 2900 63 0.50 60 52 A 12 2930 60 0.50 61 42 A 13 2040 27 0.20 59 — A 14 2050 27 0.20 56 33 A 15 2040 27 0.20 51 51 A 16 2060 26 0.20 51 39 7 300 100 P1 [W] A A 800 n [rpm] 200 9 300 400 600 5 400 1 [CFM] 800 [m3/h] General information Centrifugal fan kg Inlet nozzle (long) R3G 190-AF50 -01 1.8 09576-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 277 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 220 Frequency Speed/rpm Max. power input(1) Max. current draw(1) Perm. amb. temp. Electr. connection VAC Hz rpm W A °C p. 601 50/60 2620 75 1.10 -25 to +60 H1) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 220 M3G 055-CF 1~ 115 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations A 2 [Pa] [in H O] Curves 1,5 1,0 4 200 8 0,5 2 11 16 6 10 15 14 13 0 200 278 9 200 5 400 400 600 800 1 600 [CFM] 1000 [m3/h] LpA [dB(A)] tL [%] 1 2620 55 0.80 69 — 2 2480 64 1.00 67 55 A 3 2370 71 1.00 59 63 A 4 2450 66 1.00 63 47 A 5 2340 40 0.60 67 — A 6 2260 48 0.70 64 53 A 7 2200 53 0.80 57 62 A 8 2250 51 0.80 59 47 A 9 1890 22 0.40 64 — A 10 1820 27 0.40 60 48 A 11 1790 30 0.50 52 60 A 12 1820 28 0.40 55 45 A 13 1180 8 0.20 56 — A 14 1150 9 0.20 52 34 A 15 1130 10 0.20 42 44 A 16 1150 10 0.20 43 33 7 100 I [A] A 3 12 P1 [W] A 400 300 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 220-AD21 -02 1.4 09609-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 279 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 220 Frequency Speed/rpm Max. power input(1) Max. current draw(1) Perm. amb. temp. Electr. connection VAC Hz rpm W A °C p. 601 50/60 3030 105 0.80 -25 to +60 H1) Curve Nominal voltage – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Nominal data Type Motor R3G 220 M3G 055-CF 1~ 230 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] 400 1,5 4 8 300 0,5 6 16 10 15 14 13 0 200 280 9 200 5 400 400 600 800 1 600 [CFM] 1000 [m3/h] tL [%] 3030 80 0.60 71 — 2880 93 0.70 68 57 A 3 2750 102 0.75 62 64 A 4 2800 99 0.75 66 48 A 5 2660 54 0.40 69 — A 6 2540 64 0.50 66 56 A 7 2450 73 0.55 59 64 A 8 2500 70 0.55 63 48 A 9 2150 30 0.25 65 — A 10 2070 36 0.30 62 54 A 11 2010 41 0.30 55 62 A 12 2060 39 0.30 57 48 A 13 1340 10 0.10 58 — A 14 1310 12 0.10 55 38 A 15 1280 13 0.10 48 48 A 16 1300 13 0.10 45 36 2 100 LpA [dB(A)] 2 7 11 I [A] 1 1,0 200 P1 [W] A 3 12 n [rpm] A A 2,0 500 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 220-AD17 -02 1.4 09609-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 281 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 220 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 220 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 3590 160 2.50 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 3,0 2,5 700 600 500 2,0 4 8 3 300 7 1,0 200 0,5 11 10 100 15 14 13 200 282 9 200 0 400 400 600 800 5 1 600 [CFM] 1000 [m3/h] tL [%] 3590 158 2.00 74 — 2 3360 164 2.10 70 47 A 3 3260 160 2.00 66 58 A 4 3330 164 2.10 71 47 A 5 3110 106 1.40 72 — A 6 2890 110 1.40 66 45 A 7 2810 108 1.40 62 54 A 8 2870 114 1.50 66 44 A 9 2510 62 0.90 68 — A 10 2350 60 0.80 62 43 A 11 2280 60 0.80 56 52 A 12 2330 61 0.90 60 44 A 13 1590 21 0.30 60 — A 14 1520 23 0.30 52 31 A 15 1470 21 0.30 46 42 A 16 1500 21 0.30 50 34 6 16 LpA [dB(A)] 1 12 2 I [A] A 1,5 400 P1 [W] A A 800 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 220-AE70 -01 2.2 09609-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 283 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 220 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 220 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 3560 170 1.20 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 3,0 800 700 600 2,0 500 4 8 3 400 7 300 12 1,0 10 16 100 15 14 13 200 284 9 200 0 400 400 600 800 1 5 600 [CFM] 1000 [m3/h] I [A] LpA [dB(A)] tL [%] 1 3560 151 1.10 76 — 2 3400 172 1.20 70 51 A 3 3320 166 1.20 67 53 A 4 3440 173 1.20 71 44 A 5 3080 103 0.80 71 — A 6 3010 120 0.90 67 49 A 7 3000 123 0.90 63 53 A 8 3035 117 0.90 67 43 A 9 2500 62 0.50 67 — A 10 2435 66 0.50 63 46 A 11 2430 69 0.50 58 52 A 12 2455 71 0.50 61 41 A 13 1625 23 0.20 60 — A 14 1595 24 0.20 54 49 A 15 1595 26 0.20 48 52 A 16 1605 24 0.20 51 45 11 6 P1 [W] A 2 200 n [rpm] A A 2 [Pa] [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 220-AE50 -01 2.2 09609-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 285 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 225 Electr. connection A Perm. amb. temp. M3G 055-CF Max. current draw(1) R3G 225 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 601 50/60 2500 95 0.75 -25 to +60 H1) 1~ 230 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] 1,5 400 8 1,0 3 200 7 12 0,5 6 16 100 15 10 14 13 200 0 200 286 9 400 400 600 800 5 600 1000 1 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 2500 80 0.60 69 — 2 2380 88 0.65 62 60 A 3 2290 94 0.70 57 61 A 4 2410 84 0.65 62 45 A 5 2190 56 0.45 66 — A 6 2110 61 0.45 60 61 A 7 2050 66 0.50 54 61 A 8 2140 60 0.45 60 45 A 9 1830 34 0.25 62 — A 10 1790 38 0.30 57 60 A 11 1750 41 0.30 51 61 A 12 1810 36 0.30 54 44 A 13 1350 16 0.15 56 — A 14 1320 17 0.15 50 50 A 15 1290 19 0.15 45 53 A 16 1330 16 0.15 45 39 11 2 P1 [W] A 4 300 n [rpm] A A 2,0 500 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 225-AE11 -02 1.5 96358-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm 287 Inlet nozzle p. 550 Electr. connection p. 601 Contacts Technology Brass lead tips EC centrifugal fan backward curved, Ø 225 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 225 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2850 160 2.20 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 4 1,5 400 3 8 300 1,0 7 12 200 11 0,5 2 6 16 100 10 15 14 13 200 0 200 288 9 400 400 600 800 5 600 1 [CFM] 1000 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2850 131 1.70 70 — A 2 2800 149 1.90 67 50 A 3 2760 155 2.00 62 59 A 4 2845 136 1.70 66 45 A 5 2460 84 1.10 67 — A 6 2420 95 1.30 63 50 A 7 2410 102 1.30 59 58 A 8 2460 91 1.20 63 44 A 9 2020 51 0.70 63 — A 10 1990 58 0.80 61 46 A 11 1980 60 0.80 54 56 A 12 2010 52 0.70 57 42 A 13 1350 20 0.30 56 — A 14 1340 21 0.30 52 37 A 15 1340 23 0.40 44 45 A 16 1350 21 0.30 35 32 A 600 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 225-AH71 -01 2.3 96358-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 289 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 225 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 225 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 3010 165 1.20 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 3,0 800 700 600 2,0 8 400 3 300 7 1,0 12 11 200 2 16 6 15 100 10 14 200 290 13 400 200 0 400 600 9 800 5 600 1 [CFM] 1000 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] 1 3010 139 1.00 71 — A 2 2930 153 1.10 67 43 A 3 2900 162 1.20 63 52 A 4 2970 148 1.10 68 39 A 5 2640 97 0.70 68 — A 6 2600 105 0.80 64 44 A 7 2570 116 0.90 60 57 A 8 2605 100 0.80 65 43 A 9 2190 59 0.50 65 — A 10 2150 67 0.50 61 46 A 11 2135 71 0.60 55 56 A 12 2160 62 0.50 59 44 A 13 1540 27 0.20 61 — A 14 1530 29 0.20 53 43 A 15 1520 31 0.30 47 55 A 16 1530 28 0.20 50 42 4 500 n [rpm] A A 2 [Pa] [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 225-AH54 -01 2.3 96358-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 291 Inlet nozzle p. 550 Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 250 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 250 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2630 145 1.90 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] 2,5 [in H O] Curves 2,0 500 4 1,5 400 8 3 300 1,0 7 12 200 11 0,5 100 6 15 10 14 13 0 200 200 292 9 400 400 600 5 1 600 800 1000 [CFM] 1200 [m3/h] I [A] LpA [dB(A)] tL [%] 1 2630 106 1.40 70 — A 2 2540 127 1.60 66 57 A 3 2480 140 1.80 61 60 A 4 2560 125 1.60 67 47 A 5 2315 72 1.00 68 — A 6 2240 90 1.20 63 54 A 7 2200 99 1.40 59 60 A 8 2260 87 1.20 63 46 A 9 1900 43 0.70 66 — A 10 1870 55 0.80 60 51 A 11 1835 60 0.90 53 58 A 12 1860 53 0.80 58 43 A 13 1290 18 0.30 58 — A 14 1275 21 0.40 52 40 A 15 1250 22 0.40 44 49 A 16 1270 19 0.30 48 37 2 16 P1 [W] A A 600 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AH74 -01 2.5 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 293 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 250 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 250 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: PA plastic 6.6, fibreglass-reinforced Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 7 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2760 160 1.20 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 700 500 2,0 600 4 400 8 3 300 7 1,0 12 11 200 2 6 16 100 15 10 14 13 0 200 200 294 9 400 400 600 5 600 800 1000 1 [CFM] 1200 [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2760 123 0.90 71 — A 2 2660 148 1.10 66 54 A 3 2600 162 1.20 62 57 A 4 2680 147 1.10 68 42 A 5 2460 88 0.70 68 — A 6 2380 106 0.80 63 53 A 7 2340 116 0.90 59 57 A 8 2400 105 0.80 65 42 A 9 2000 53 0.40 65 — A 10 1960 62 0.50 60 54 A 11 1940 69 0.50 55 58 A 12 1965 61 0.50 59 42 A 13 1380 22 0.20 58 — A 14 1360 25 0.20 52 50 A 15 1350 28 0.25 47 57 A 16 1360 25 0.20 50 43 General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AH52 -01 2.5 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Core-end sleeves 295 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Accessories EC-SYSTEMS Depth of screw 8-10 mm EC centrifugal fan backward curved, Ø 250 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw(1) R3G 250 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2490 125 1.80 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations n [rpm] 2 [Pa] 4 1,5 400 3 8 1,0 300 7 12 200 11 0,5 2 6 100 16 10 15 14 13 0 200 296 9 200 400 400 600 1 5 600 800 1000 [CFM] 1200 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2490 97 1.30 72 — A 2 2380 119 1.60 66 62 A 3 2330 123 1.60 60 64 A 4 2410 110 1.40 67 47 A 5 2110 60 0.80 71 — A 6 2040 78 1.00 63 58 A 7 2010 79 1.10 58 64 A 8 2070 71 1.00 64 45 A 9 1700 35 0.50 66 — A 10 1660 44 0.60 58 56 A 11 1650 47 0.70 52 59 A 12 1670 39 0.60 58 43 A 13 1040 11 0.20 57 — A 14 1030 14 0.20 50 40 A 15 1030 15 0.20 41 46 A 16 1040 13 0.20 44 31 A 2,0 500 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AL75 -01 2.9 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 297 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 250 Electr. connection A Perm. amb. temp. M3G 074-CF Max. current draw(1) R3G 250 Max. power input(1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2800 175 1.30 -25 to +60 J1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 700 600 500 2,0 4 8 400 3 1,0 12 11 200 2 6 16 100 10 15 14 0 200 298 13 400 200 400 600 800 9 600 5 1000 1200 1 800 1400 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2800 142 1.10 74 — A 2 2650 164 1.25 69 53 A 3 2570 164 1.25 63 59 A 4 2720 154 1.20 72 44 A 5 2550 104 0.80 71 — A 6 2470 124 1.00 66 53 A 7 2440 134 1.00 61 58 A 8 2510 123 0.90 69 44 A 9 2080 62 0.50 67 — A 10 2025 74 0.60 62 54 A 11 2020 78 0.60 56 60 A 12 2050 70 0.60 62 43 A 13 1370 24 0.20 59 — A 14 1340 27 0.20 53 51 A 15 1330 28 0.20 46 57 A 16 1340 25 0.20 51 44 7 300 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AL54 -01 2.9 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 299 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 250 Electr. connection A Perm. amb. temp. M3G 074-CF Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2570 170 2.20 -25 to +60 J1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations [Pa] 2 4 400 1,5 300 1,0 2 200 11 0,5 16 10 15 14 0 200 300 13 400 200 400 600 9 5 600 800 1000 800 1200 1400 1 [CFM] [m3/h] LpA [dB(A)] tL [%] 2570 147 1.90 73 — 2 2440 167 2.10 66 62 A 3 2420 166 2.10 62 63 A 4 2580 147 1.90 69 44 A 5 2220 106 1.30 71 — A 6 2100 108 1.40 64 60 A 7 2090 110 1.50 60 58 A 8 2220 93 1.20 65 45 A 9 1820 59 0.80 69 — A 10 1730 67 0.90 60 54 A 11 1720 66 0.90 54 55 A 12 1810 59 0.80 60 39 A 13 1220 23 0.30 62 — A 14 1180 27 0.40 52 43 A 15 1180 25 0.40 44 46 A 16 1210 23 0.30 48 30 6 100 I [A] 1 7 12 P1 [W] A 3 8 n [rpm] A A 2,0 500 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AM70 -01 3.0 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 301 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 250 Electr. connection A Perm. amb. temp. M3G 074-CF Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2510 178 1.40 -25 to +60 J1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 4 400 3 8 300 1,0 2 200 11 6 16 100 10 15 14 0 200 302 13 400 200 400 600 800 9 600 5 1000 1200 1 [CFM] 1400 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2510 140 1.00 73 — A 2 2450 166 1.20 66 53 A 3 2440 172 1.20 62 56 A 4 2520 143 1.00 68 41 A 5 2170 99 0.75 69 — A 6 2140 112 0.90 64 52 A 7 2130 115 0.90 59 54 A 8 2170 95 0.80 63 40 A 9 1770 55 0.40 66 — A 10 1750 67 0.50 58 52 A 11 1750 67 0.50 54 53 A 12 1765 59 0.50 59 39 A 13 1230 26 0.20 59 — A 14 1240 27 0.30 51 50 A 15 1220 29 0.30 45 56 A 16 1240 27 0.30 48 43 7 12 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AM50 -01 3.0 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 303 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 250 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 3240 350 4.20 -25 to +60 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] 3,0 800 4 2,0 600 3 400 1,0 2 200 1 0 250 400 304 500 800 750 1200 1000 1600 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 3240 267 3.30 77 — A 2 3160 339 4.10 73 54 A 3 3165 350 4.20 71 58 A 4 3210 314 3.80 73 52 A 4,0 1000 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AK29 -81 4.5 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 305 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 250 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 3580 485 3.00 -25 to +60 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] A 4,0 1000 [in H O] Curves 4 3,0 800 3 600 2,0 8 7 400 2 1,0 12 6 11 200 10 5 9 0 250 400 306 500 800 750 1200 1000 1600 1 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 3580 380 2.30 80 — A 2 3460 465 3.00 77 53 A 3 3460 485 3.00 74 58 A 4 3520 440 2.40 76 50 A 5 2830 193 1.20 75 — A 6 2830 245 1.50 70 53 A 7 2830 260 1.60 69 58 A 8 2830 225 1.40 69 50 A 9 2000 80 0.50 68 — A 10 2000 100 0.60 62 53 A 11 2000 106 0.70 59 58 A 12 2000 94 0.60 60 50 General information Centrifugal fan kg Inlet nozzle (long) R3G 250-AK41 -71 4.5 96359-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 307 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 280 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 1750 145 1.90 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 1,25 300 250 1,00 4 8 3 0,75 200 7 150 0,50 100 0,25 6 50 15 10 14 13 0 200 400 308 400 9 600 800 5 800 1200 1 1000 1600 [CFM] [m3/h] LpA [dB(A)] tL [%] 1 1750 107 1.40 70 — 2 1710 123 1.60 63 51 A 3 1675 138 1.80 59 67 A 4 1720 119 1.50 60 53 A 5 1550 73 1.00 66 — A 6 1530 89 1.20 61 49 A 7 1500 99 1.30 56 66 A 8 1540 86 1.10 57 52 A 9 1280 45 0.60 62 — A 10 1250 51 0.70 55 45 A 11 1230 58 0.80 51 62 A 12 1260 50 0.70 52 49 A 13 880 18 0.30 57 — A 14 870 21 0.30 51 36 A 15 870 23 0.40 46 51 A 16 880 20 0.30 40 39 2 16 I [A] A 12 11 P1 [W] A A 350 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 280-AA75 -01 3.2 96360-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 309 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 280 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 2000 170 1.30 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 1,5 300 1,0 8 3 200 7 0,5 12 2 16 6 15 10 14 13 0 250 400 310 9 500 800 5 1000 750 1200 1600 1 [CFM] 2000 [m /h] 3 I [A] LpA [dB(A)] tL [%] 1 2000 145 1.10 72 — A 2 1920 168 1.20 67 48 A 3 1790 170 1.20 61 60 A 4 1930 161 1.10 62 50 A 5 1680 89 0.70 69 — A 6 1660 113 0.90 64 46 A 7 1625 123 1.00 57 61 A 8 1660 104 0.80 58 50 A 9 1380 55 0.50 65 — A 10 1350 61 0.50 60 49 A 11 1340 72 0.60 53 60 A 12 1360 61 0.50 53 50 A 13 980 24 0.20 58 — A 14 970 28 0.30 54 47 A 15 960 32 0.30 48 60 A 16 970 27 0.30 44 51 11 100 P1 [W] A 400 4 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) R3G 280-AA52 -01 3.2 96360-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 311 Inlet nozzle p. 550 f. Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 280 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2420 350 4.20 -25 to +60 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations A 2 [Pa] [in H O] Curves 2,5 3,0 800 2,0 600 1,5 3 1,0 400 4 200 0,5 2 1 0 250 400 312 500 800 750 1200 1000 1600 1250 2000 1500 2400 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2420 270 3.30 77 — A 2 2360 324 3.90 73 50 A 3 2320 350 4.20 69 60 A 4 2395 298 3.70 71 48 General information Centrifugal fan kg Inlet nozzle (long) R3G 280-AF23 -81 5.0 96360-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 313 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, Ø 280 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet steel, galvanised Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 11 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2600 455 2.80 -25 to +40 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 3,0 800 2,5 4 2,0 600 8 7 1,0 400 1,5 3 2 200 12 6 0,5 11 10 9 0 250 400 314 500 800 750 1200 1000 1600 5 1250 2000 1500 2400 1 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2760 355 2.20 80 — A 2 2670 400 2.50 77 48 A 3 2660 425 2.60 73 60 A 4 2740 386 2.30 75 45 A 5 2050 150 1.00 74 — A 6 2050 206 1.10 71 48 A 7 2050 232 1.40 67 60 A 8 2050 196 1.20 67 45 A 9 1460 65 0.40 67 — A 10 1460 80 0.50 64 48 A 11 1460 88 0.60 58 60 A 12 1460 70 0.50 57 45 General information Centrifugal fan kg Inlet nozzle (long) R3G 280-AF35 -71 5.0 96360-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA; CCC, GOST are applied for Accessories EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 315 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) R3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 1700 160 2.10 -25 to +60 J1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 1,5 1,0 8 3 200 7 12 0,5 11 100 16 2 6 15 10 14 13 0 250 400 316 9 500 800 5 750 1200 1000 1600 1 [CFM] 2000 [m /h] 3 I [A] LpA [dB(A)] tL [%] 1 1700 111 1.50 65 — A 2 1640 133 1.70 62 64 A 3 1600 152 1.90 58 75 A 4 1630 140 1.80 60 55 A 5 1530 80 1.10 62 — A 6 1480 98 1.30 60 63 A 7 1450 110 1.50 55 75 A 8 1470 103 1.40 58 58 A 9 1270 50 0.70 58 — A 10 1240 61 0.80 55 57 A 11 1220 68 0.90 52 73 A 12 1230 64 0.90 53 54 A 13 920 22 0.40 49 — A 14 900 26 0.40 46 49 A 15 890 30 0.50 43 64 A 16 900 28 0.40 45 48 400 300 P1 [W] A A 4 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 310-AO75 -01 3.1 31050-2-4013 31051-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA, CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Inlet nozzle (long) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 317 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) R3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 1925 173 1.30 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves (established with long inlet nozzle) 400 1,5 4 8 300 1,0 3 7 12 200 0,5 11 16 6 15 10 14 13 0 250 400 318 500 750 800 1000 1200 9 1250 1600 5 1500 2000 1 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1925 150 1.10 67 — A 2 1840 174 1.20 65 61 A 3 1700 172 1.20 59 71 A 4 1790 174 1.20 62 55 A 5 1670 100 0.80 64 — A 6 1615 128 1.00 61 60 A 7 1590 139 1.00 55 71 A 8 1610 134 1.00 60 53 A 9 1400 60 0.50 59 — A 10 1360 76 0.60 57 60 A 11 1340 85 0.70 54 73 A 12 1355 81 0.70 56 54 A 13 1030 28 0.30 51 — A 14 1010 35 0.30 49 59 A 15 990 40 0.30 45 72 A 16 1000 38 0.30 47 53 2 100 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 310-AO52 -01 3.1 31050-2-4013 31051-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Inlet nozzle (long) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 319 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fan backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) R3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, laser-welded Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 603 50/60 1770 175 1.30 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves (established with long inlet nozzle) 1,5 400 1,0 8 0,5 7 2 12 100 11 6 10 9 0 250 500 600 320 750 1200 1 1500 5 1000 1800 1250 2400 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1770 170 1.25 65 — A 2 1570 170 1.30 60 59 A 3 1510 167 1.30 58 65 A 4 1630 169 1.20 62 49 A 5 1300 73 0.60 56 — A 6 1270 88 0.70 54 59 A 7 1250 100 0.80 54 65 A 8 1280 84 0.70 56 48 A 9 930 29 0.30 48 — A 10 910 37 0.30 45 56 A 11 900 40 0.35 45 67 A 12 910 34 0.30 46 47 3 200 P1 [W] A 4 300 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) R3G 310-AP52 -01 3.2 31050-2-4013 31051-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Inlet nozzle (long) EC centrifugal, forward Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Accessories EC-SYSTEMS Depth of screw 8-10 mm 321 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 603 Contacts Technology Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2300 350 4.20 -25 to +60 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) A 3,5 1000 4 2,0 600 2,5 3,0 800 1,5 400 3 1,0 2 0,5 200 1 0 500 500 322 1000 1000 1500 1500 2000 2500 [CFM] 3000 [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2300 262 3.30 75 — A 2 2190 338 4.10 69 64 A 3 2180 350 4.20 71 67 A 4 2260 307 3.70 70 52 General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 310-AJ23 -81 4.4 31050-2-4013 31051-2-4013 K3G 310-AJ23 -82 7.3 K3G 310-AJ23 -81 7.0 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support bracket Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 192,4±3 143,9 2,5 440±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 350±1 5 tes! minu 6,4±0,2 8 85 1000±50 420±0,5 323 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2590 505 3.10 -25 to +60 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 800 3,0 4 2,5 3 2 11 1,0 6 200 10 0,5 16 15 14 9 13 0 500 500 324 LpA [dB(A)] tL [%] 1 2590 380 2.30 78 — 2 2500 470 2.80 74 63 A 3 2470 505 3.00 73 67 A 4 2530 460 2.70 74 52 A 5 2320 274 1.60 75 — A 6 2320 370 2.20 71 63 A 7 2320 410 2.40 71 67 A 8 2320 362 2.10 71 52 A 9 1810 137 0.90 69 — A 10 1810 175 1.10 65 63 A 11 1810 198 1.20 64 67 A 12 1810 180 1.10 64 52 A 13 1110 42 0.30 55 — A 14 1110 54 0.40 52 63 A 15 1110 57 0.40 52 67 A 16 1110 54 0.40 52 52 12 1,5 400 7 I [A] A 8 2,0 600 P1 [W] A 3,5 1000 n [rpm] 1000 1000 1500 5 1 1500 2000 2500 [CFM] 3000 [m3/h] General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 310-AJ40 -71 4.4 31050-2-4013 31051-2-4013 K3G 310-AJ40 -72 7.3 K3G 310-AJ40 -71 7.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 192,4±3 143,9 2,5 440±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 350±1 5 tes! minu 6,4±0,2 8 85 1000±50 420±0,5 325 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2080 350 4.20 -25 to +60 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2,5 700 600 2,0 4 500 1,5 400 3 1,0 300 2 0,5 200 100 1 0 500 500 326 1000 1500 1000 1500 2000 2500 [CFM] 3000 [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2080 274 3.40 71 — A 2 1980 338 4.10 68 63 A 3 1950 350 4.20 66 67 A 4 2035 301 3.70 69 52 A 2 [Pa] [in H O] Curves (established with long inlet nozzle) General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 310-AI01 -81 4.5 31050-2-4013 31051-2-4013 K3G 310-AI01 -82 7.6 K3G 310-AI01 -81 7.1 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 223,5±3 175 2,5 440±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 350±1 5 tes! minu 6,4±0,2 8 85 1000±50 420±0,5 327 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 310 Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 2300 480 3.10 -25 to +60 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 500 400 2,8 2,4 4 2,0 600 3 8 1,6 700 300 1,2 7 12 2 0,8 11 200 6 16 15 0,4 100 10 14 0 500 328 1000 1500 1 [CFM] 5 9 13 1000 500 1500 2000 2500 3000 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2300 370 2.35 75 — A 2 2215 445 2.85 71 62 A 3 2170 480 3.10 68 67 A 4 2220 448 2.85 70 56 A 5 1900 210 1.30 69 — A 6 1900 284 1.70 66 62 A 7 1900 312 1.80 63 67 A 8 1900 278 1.70 66 56 A 9 1560 124 0.80 63 — A 10 1560 158 1.00 61 62 A 11 1560 175 1.10 57 67 A 12 1560 158 1.00 61 56 A 13 1200 57 0.40 56 — A 14 1200 73 0.50 54 62 A 15 1200 80 0.50 53 67 A 16 1200 70 0.50 53 56 A 800 n [rpm] General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 310-AI39 -71 4.5 31050-2-4013 31051-2-4013 K3G 310-AI39 -72 7.6 K3G 310-AI39 -71 7.1 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 223,5±3 175 2,5 440±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 350±1 5 tes! minu 6,4±0,2 8 85 1000±50 420±0,5 329 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 355 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1730 355 4.10 -25 to +60 K1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 2,5 700 500 2,0 600 4 1,5 400 3 1,0 300 200 0,5 2 100 1 0 500 500 330 1000 1000 1500 1500 2000 2500 2000 3000 3500 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1730 278 3.20 74 — A 2 1675 338 3.90 69 58 A 3 1650 355 4.20 66 70 A 4 1700 310 3.60 68 60 General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AM36 -81 5.7 35560-2-4013 35561-2-4013 K3G 355-AM36 -82 9.2 K3G 355-AM36 -81 8.8 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 2,5 496±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 5 tes! minu 6,4±0,2 8 85 1000±50 476±0,5 331 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts 233,5±3 185 380±1 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 355 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1970 500 3.15 -25 to +60 K1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 400 300 2,4 2,0 500 4 8 7 12 0,8 2 200 0,4 100 16 10 15 14 0 500 500 332 1000 9 13 1000 1500 5 1500 2000 2500 2000 3000 3500 1 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1970 390 2.50 77 — A 2 1920 469 2.95 73 56 A 3 1880 500 3.15 69 70 A 4 1925 476 3.00 71 62 A 5 1580 200 1.20 71 — A 6 1580 260 1.50 67 56 A 7 1580 290 1.70 64 70 A 8 1580 265 1.60 64 62 A 9 1280 110 0.70 65 — A 10 1280 144 0.90 61 56 A 11 1280 157 1.00 58 70 A 12 1280 132 0.80 59 62 A 13 910 44 0.30 55 — A 14 910 57 0.40 52 56 A 15 910 62 0.40 49 70 A 16 910 48 0.40 50 62 11 6 P1 [W] A 3 1,6 600 1,2 700 2,8 800 n [rpm] General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AM29 -71 5.7 35560-2-4013 35561-2-4013 K3G 355-AM29 -72 9.2 K3G 355-AM29 -71 8.8 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 2,5 496±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 5 tes! minu 6,4±0,2 8 85 1000±50 476±0,5 333 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts 233,5±3 185 380±1 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 355 Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1630 350 4.20 -25 to +60 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 2,5 700 500 2,0 600 4 1,5 400 300 1,0 3 200 0,5 2 100 1 0 500 500 334 1000 1000 1500 1500 2000 2500 2000 3000 3500 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1630 283 3.50 72 — A 2 1580 344 4.00 68 58 A 3 1570 350 4.20 64 68 A 4 1605 319 3.90 67 57 General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AN37 -81 5.8 35560-2-4013 35561-2-4013 K3G 355-AN37 -82 10.0 K3G 355-AN37 -81 9.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 2,5 496±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 5 tes! minu 6,4±0,2 8 85 1000±50 476±0,5 335 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts 257,5±3 209 380±1 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 355 Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1770 450 2.90 -25 to +60 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2,5 600 2,0 500 4 8 400 1,5 3 7 12 300 1,0 11 16 200 2 15 6 0,5 10 14 100 0 500 500 336 1000 13 1500 1000 1500 2000 2500 9 5 2000 3000 3500 1 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] 1 1770 362 2.30 73 — A 2 1720 434 2.75 68 58 A 3 1710 450 2.90 64 68 A 4 1745 412 2.60 67 57 A 5 1620 270 1.60 73 — A 6 1620 360 2.10 67 58 A 7 1620 375 2.20 63 68 A 8 1620 335 2.00 65 57 A 9 1400 182 1.10 67 — A 10 1400 235 1.40 64 58 A 11 1400 247 1.50 59 68 A 12 1400 218 1.30 62 57 A 13 1200 120 0.80 62 — A 14 1200 152 1.00 59 58 A 15 1200 160 1.00 56 68 A 16 1200 140 0.90 57 57 A 700 n [rpm] A 2 [Pa] [in H O] Curves (established with long inlet nozzle) General information kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AN04 -71 5.8 35560-2-4013 35561-2-4013 K3G 355-AN04 -72 10.0 K3G 355-AN04 -71 9.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 2,5 496±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 5 tes! minu 6,4±0,2 8 85 1000±50 476±0,5 337 Inlet nozzle p. 550 f. Electr. connection p. 605 Contacts 257,5±3 209 380±1 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 355 Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 2035 0.74 3.34 -25 to +60 L1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2,5 700 4 500 2,0 600 n [rpm] P1 [kW] I [A] LwA [dB(A)] tL [%] A 1 2035 0.57 2.60 84 — A 2 2035 0.69 3.10 81 52 A 3 2035 0.74 3.30 78 64 A 4 2035 0.70 3.10 82 61 A 5 1585 0.28 1.30 76 — A 6 1580 0.32 1.50 73 52 A 7 1580 0.34 1.60 71 71 A 8 1580 0.33 1.50 73 68 A 9 1150 0.12 0.60 67 — A 10 1145 0.14 0.70 64 54 A 11 1140 0.15 0.70 63 74 A 12 1145 0.14 0.60 64 72 A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 3 400 1,5 8 300 7 1,0 2 12 200 6 0,5 11 100 10 0 500 1000 338 9 1500 1000 2000 5 2000 3000 1 2500 4000 [CFM] [m3/h] General information Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AI52 -11 7.3 35560-2-4013 35561-2-4013 K3G 355-AI52 -12 15.8 K3G 355-AI52 -11 18.6 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal module with support bracket Mass of centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Technology Accessories Depth of screw 12-16 mm 339 Inlet nozzle p. 550 f. Electr. connection p. 607 Contacts Cable gland EC-SYSTEMS EC centrifugal, forward Inlet nozzle (long) EC centrifugal fans and modules backward curved, 3-D, Ø 355 Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 2215 0.94 3.00 -25 to +60 L2) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations 3,0 600 3 2,0 8 400 7 2 1,0 12 200 6 11 10 9 0 500 1000 340 1000 1500 2000 5 2000 3000 2500 4000 1 [CFM] [m3/h] P1 [kW] I [A] LwA [dB(A)] tL [%] 1 2205 0.70 2.50 87 — A 2 2215 0.88 2.80 83 48 A 3 2215 0.94 3.00 80 59 A 4 2215 0.85 2.70 85 53 A 5 1825 0.38 1.50 82 — A 6 1805 0.47 1.70 77 52 A 7 1790 0.49 1.80 73 65 A 8 1800 0.46 1.90 77 58 A 9 1335 0.17 0.70 72 — A 10 1315 0.20 0.80 68 57 A 11 1315 0.21 0.90 65 69 A 12 1310 0.19 0.80 67 60 800 4 n [rpm] A A 2 [Pa] [in H O] Curves (established with long inlet nozzle) General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AI62 -06 7.3 35560-2-4013 35561-2-4013 K3G 355-AI62 -07 15.8 K3G 355-AI62 -06 18.6 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal module with support bracket Mass of centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Technology Accessories Depth of screw 12-16 mm 341 Inlet nozzle p. 550 f. Electr. connection p. 607 Contacts Cable gland EC-SYSTEMS EC centrifugal, forward Inlet nozzle (long) EC centrifugal fans and modules backward curved, 3-D, Ø 355 Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 2215 0.94 1.50 -25 to +60 L2) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 3,0 600 3 2,0 8 400 7 2 1,0 12 200 6 11 10 9 0 500 1000 342 1000 1500 2000 5 2000 3000 2500 4000 1 [CFM] [m3/h] P1 [kW] I [A] LwA [dB(A)] tL [%] 1 2205 0.70 1.30 87 — A 2 2215 0.88 1.40 83 48 A 3 2215 0.94 1.50 80 59 A 4 2215 0.85 1.40 85 53 A 5 1825 0.38 0.70 82 — A 6 1805 0.47 0.90 77 52 A 7 1790 0.49 0.90 73 65 A 8 1800 0.46 0.90 77 58 A 9 1335 0.17 0.40 72 — A 10 1315 0.20 0.40 68 57 A 11 1315 0.21 0.40 65 69 A 12 1310 0.19 0.40 67 60 800 4 n [rpm] A A 2 [Pa] [in H O] Curves (established with long inlet nozzle) General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 355-AI56 -01 7.3 35560-2-4013 35561-2-4013 K3G 355-AI56 -02 15.8 K3G 355-AI56 -01 18.6 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal module with support bracket Mass of centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Technology Accessories Depth of screw 12-16 mm 343 Inlet nozzle p. 550 f. Electr. connection p. 607 Contacts Cable gland EC-SYSTEMS EC centrifugal, forward Inlet nozzle (long) EC centrifugal fans and modules backward curved, 3-D, Ø 400 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1460 350 4.20 -25 to +60 K1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations A 2 [Pa] [in H O] Curves 600 2,4 500 2,0 700 2,8 800 400 1,6 4 1,2 200 0,8 100 0,4 3 300 2 0 500 500 344 1000 1000 1500 1 2000 1500 2000 2500 3000 3500 [CFM] [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1460 299 3.60 73 — A 2 1415 346 4.10 66 58 A 3 1415 350 4.20 62 70 A 4 1465 298 3.60 66 60 General information AC centrifugal, backward AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AD42 -81 6.1 54476-2-4013 K3G 400-AD42 -82 10.7 K3G 400-AD42 -81 9.9 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 246,4±3 197,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 345 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1460 360 2.20 -25 to +60 K1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 500 2,0 600 4 n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1460 302 1.85 72 — A 2 1425 344 2.10 67 48 A 3 1420 360 2.20 63 67 A 4 1460 309 1.90 67 55 A 5 1270 195 1.20 68 — A 6 1270 235 1.40 64 53 A 7 1270 250 1.50 61 67 A 8 1270 205 1.30 63 54 A 9 900 74 0.50 60 — A 10 900 90 0.60 56 53 A 11 900 90 0.60 52 67 A 12 900 77 0.50 44 54 1,5 400 8 3 300 1,0 7 200 12 2 6 0,5 11 100 10 5 9 0 500 500 346 1000 1500 1000 1500 2000 2500 3000 1 2000 3500 [CFM] [m3/h] General information AC centrifugal, backward AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AD32 -71 6.1 54476-2-4013 K3G 400-AD32 -72 10.7 K3G 400-AD32 -71 9.9 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, CCC; VDE, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 246,4±3 197,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 347 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1320 325 3.90 -25 to +60 K1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 1,5 400 4 300 1,0 3 200 0,5 2 100 0 500 500 348 1000 1000 1500 1500 2000 2500 2000 3000 3500 1 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1320 275 3.40 72 — A 2 1275 317 3.80 66 60 A 3 1285 325 3.90 63 70 A 4 1320 285 3.50 66 57 A 600 n [rpm] General information AC centrifugal, backward AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AC42 -81 6.2 54476-2-4013 K3G 400-AC42 -82 11.0 K3G 400-AC42 -81 10.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 269,4±3 220,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 349 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Electr. connection A Perm. amb. temp. M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1365 355 2.20 -25 to +60 K1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] 400 1,5 4 300 1,0 3 7 2 0,5 12 100 11 6 10 500 500 350 1000 1000 1500 1500 2000 1 5 9 0 2500 2000 3000 3500 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] 1 1365 306 1.90 72 — A 2 1335 339 2.05 70 48 A 3 1320 355 2.20 65 64 A 4 1350 324 2.00 68 54 A 5 1080 152 0.95 67 — A 6 1080 180 1.10 63 48 A 7 1080 195 1.20 60 64 A 8 1080 165 1.00 61 54 A 9 790 59 0.35 60 — A 10 790 70 0.45 56 48 A 11 790 76 0.45 52 64 A 12 790 65 0.40 53 54 8 200 n [rpm] A A 2,0 500 [in H O] Curves General information AC centrifugal, backward AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AC28 -71 6.2 54476-2-4013 K3G 400-AC28 -72 11.0 K3G 400-AC28 -71 10.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 269,4±3 220,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 351 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1400 380 4.50 -25 to +40 K1) 1~ 100-130 A (1) Nominal data in operating point with maximum load and 115 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 4 1,5 400 3 1,0 300 2 0,5 200 100 1 0 500 500 352 1000 1000 1500 1500 2000 2500 2000 3000 3500 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1400 328 3.90 74 — A 2 1360 381 4.50 68 59 A 3 1365 380 4.50 65 68 A 4 1420 317 3.80 69 55 A 600 n [rpm] General information AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AC15 -81 6.2 54476-2-4013 K3G 400-AC15 -82 11.0 K3G 400-AC15 -81 10.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal module with support bracket Mass of centrifugal fan AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 269,4±3 220,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 353 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 1410 410 2.50 -25 to +40 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 4 P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1410 359 2.20 74 — A 2 1370 401 2.45 69 51 A 3 1375 410 2.50 66 64 A 4 1420 352 2.15 71 54 A 5 1110 161 1.00 68 — A 6 1110 120 0.80 63 51 A 7 1110 194 1.20 59 64 A 8 1110 151 1.00 61 54 A 9 800 69 0.50 60 — A 10 800 80 0.50 56 51 A 11 800 78 0.50 52 64 A 12 800 55 0.40 53 54 A 600 n [rpm] 1,5 400 3 300 1,0 8 7 200 2 0,5 12 6 11 100 10 5 9 0 500 500 354 1000 1000 1500 1500 2000 2500 2000 3000 3500 1 [CFM] [m3/h] General information AC centrifugal, backward AC centrifugal, forward kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AC32 -71 6.2 54476-2-4013 K3G 400-AC32 -72 11.0 K3G 400-AC32 -71 10.0 EC centrifugal, backward for clean rooms Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 269,4±3 220,9 2,5 560±2 ! ! ION s min! 5 teur ges! time ensa e ses! cond volta us harg ereu des gero r disc dang arge Dan acito ions dech Cap Tens de ps Tem NT Technology TE ING AT RN WA 409±1 5 tes! minu 6,4±0,2 8 85 1000±50 520±0,5 355 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts 48,5 Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 400 Electr. connection A Perm. amb. temp. M3G 112-EA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1720 0.76 3.40 -25 to +60 L1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 2,5 4 500 2,0 600 3 8 7 1,0 300 2 12 200 6 0,5 11 100 10 9 0 500 1000 356 1000 1500 2000 5 2000 3000 2500 4000 1 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1720 0.60 2.70 84 — A 2 1725 0.72 3.20 80 51 A 3 1720 0.76 3.40 75 62 A 4 1725 0.68 3.00 79 59 A 5 1455 0.35 1.60 79 — A 6 1430 0.39 1.80 74 54 A 7 1425 0.40 1.80 71 69 A 8 1435 0.37 1.70 73 62 A 9 1045 0.15 0.70 68 — A 10 1030 0.16 0.70 65 60 A 11 1030 0.16 0.80 63 74 A 12 1040 0.15 0.70 64 67 1,5 400 P1 [kW] A A 700 n [rpm] General information AC centrifugal, backward Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AM56 -11 7.7 54476-2-4013 K3G 400-AM56 -12 16.2 K3G 400-AM56 -11 19.0 EC centrifugal, backward for clean rooms kg EC-SYSTEMS EC centrifugal, forward Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 357 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 400 Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1755 0.77 2.60 -25 to +60 L2) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations 2 [Pa] [in H O] Curves 2,5 4 500 2,0 600 8 3 7 300 1,0 12 2 200 6 0,5 11 10 100 9 0 500 1000 358 1000 1500 2000 2000 3000 5 2500 4000 1 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1755 0.63 2.20 84 — A 2 1760 0.75 2.50 80 51 A 3 1760 0.77 2.60 75 62 A 4 1760 0.72 2.40 79 56 A 5 1510 0.40 1.60 80 — A 6 1470 0.42 1.60 74 54 A 7 1465 0.43 1.60 72 69 A 8 1485 0.41 1.60 74 65 A 9 1100 0.17 0.80 70 — A 10 1090 0.18 0.80 65 62 A 11 1085 0.18 0.80 64 78 A 12 1095 0.18 0.80 66 71 1,5 400 P1 [kW] A A 700 n [rpm] General information AC centrifugal, backward Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AM61 -06 7.7 54476-2-4013 K3G 400-AM61 -07 16.2 K3G 400-AM61 -06 19.0 EC centrifugal, backward for clean rooms kg EC-SYSTEMS EC centrifugal, forward Centrifugal fan EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 359 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 400 Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1755 0.77 1.30 -25 to +60 L2) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 2 [Pa] [in H O] Curves 2,5 4 500 2,0 600 8 3 7 300 1,0 12 2 200 6 0,5 11 10 100 9 0 500 1000 360 1000 1500 2000 2000 3000 5 2500 4000 1 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1755 0.63 1.10 84 — A 2 1760 0.75 1.30 80 51 A 3 1760 0.77 1.30 75 62 A 4 1760 0.72 1.20 79 56 A 5 1510 0.40 0.80 80 — A 6 1470 0.42 0.80 74 54 A 7 1465 0.43 0.80 72 69 A 8 1485 0.41 0.80 74 65 A 9 1100 0.17 0.40 70 — A 10 1090 0.18 0.40 65 62 A 11 1085 0.18 0.40 64 78 A 12 1095 0.18 0.40 66 71 1,5 400 P1 [kW] A A 700 n [rpm] General information AC centrifugal, backward AC centrifugal, forward Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg R3G 400-AM55 -01 7.7 54476-2-4013 K3G 400-AM55 -02 16.2 K3G 400-AM55 -01 19.0 EC centrifugal, backward EC-SYSTEMS EC centrifugal, forward Centrifugal fan EC centrifugal, backward for clean rooms Mass of centrifugal module with support bracket Mass of centrifugal fan • • • • • Mass of centrifugal module with support plate – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 361 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 450 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1365 0.64 2.90 -25 to +60 L1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] 1,5 3 300 7 2 200 0,5 12 6 11 100 10 0 1000 362 9 2000 1000 2000 3000 1 5 3000 4000 5000 [CFM] 6000 [m3/h] I [A] LwA [dB(A)] tL [%] 1 1365 0.48 2.20 80 — 2 1345 0.60 2.70 75 57 A 3 1330 0.64 2.90 71 66 A 4 1340 0.62 2.80 73 60 A 5 1065 0.23 1.10 74 — A 6 1065 0.29 1.40 68 58 A 7 1055 0.32 1.50 66 66 A 8 1060 0.30 1.40 67 61 A 9 760 0.10 0.50 65 — A 10 760 0.12 0.60 59 57 A 11 760 0.13 0.60 58 68 A 12 760 0.12 0.60 59 63 1,0 8 P1 [kW] A 4 400 n [rpm] A A 2,0 500 [in H O] Curves 12.1 AC centrifugal, forward AC centrifugal, backward General information R3G 450-AG33 -11 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63045-2-4013 K3G 450-AG33 -12 22.2 K3G 450-AG33 -11 26.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC-SYSTEMS EC centrifugal, forward Centrifugal fan • • • • • Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 363 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 450 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1560 1.01 3.20 -25 to +60 L2) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations 2 [Pa] 2,5 [in H O] Curves 4 2,0 500 3 8 1,5 300 1,0 2 12 200 6 0,5 11 10 100 9 0 1000 1000 364 2000 3000 4000 1 5 3000 2000 5000 [CFM] 6000 [m3/h] I [A] LwA [dB(A)] tL [%] 1 1560 0.69 2.30 83 — A 2 1555 0.91 2.90 78 58 A 3 1555 1.01 3.20 74 67 A 4 1560 0.96 3.10 77 60 A 5 1345 0.43 1.60 80 — A 6 1315 0.53 2.00 73 60 A 7 1300 0.58 2.00 70 71 A 8 1315 0.54 1.90 72 62 A 9 985 0.19 0.80 71 — A 10 970 0.22 0.90 65 62 A 11 965 0.25 1.00 62 75 A 12 970 0.23 0.90 64 67 400 7 P1 [kW] A A 600 n [rpm] 12.1 AC centrifugal, forward AC centrifugal, backward General information R3G 450-AG38 -06 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63045-2-4013 K3G 450-AG38 -07 22.2 K3G 450-AG38 -06 26.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC-SYSTEMS EC centrifugal, forward Centrifugal fan • • • • • Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 365 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 450 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1560 1.01 1.60 -25 to +60 L2) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 2 [Pa] 2,5 [in H O] Curves 4 2,0 500 3 8 1,5 300 1,0 2 12 200 6 0,5 11 10 100 9 0 1000 1000 366 2000 3000 4000 1 5 3000 2000 5000 [CFM] 6000 [m3/h] I [A] LwA [dB(A)] tL [%] 1 1560 0.69 1.10 83 — A 2 1555 0.91 1.50 78 58 A 3 1555 1.01 1.60 74 67 A 4 1560 0.96 1.50 77 60 A 5 1345 0.43 0.80 80 — A 6 1315 0.53 1.00 73 60 A 7 1300 0.58 1.00 70 71 A 8 1315 0.54 1.00 72 62 A 9 985 0.19 0.40 71 — A 10 970 0.22 0.50 65 62 A 11 965 0.25 0.50 62 75 A 12 970 0.23 0.50 64 67 400 7 P1 [kW] A A 600 n [rpm] 12.1 AC centrifugal, forward AC centrifugal, backward General information R3G 450-AG33 -01 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63045-2-4013 K3G 450-AG33 -02 22.2 K3G 450-AG33 -01 26.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC-SYSTEMS EC centrifugal, forward Centrifugal fan • • • • • Mass of centrifugal module with support plate Mass of centrifugal fan Mass of centrifugal module with support bracket – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for Depth of screw 12-16 mm 367 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 450 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 2165 2.63 9.80 -25 to +50 M) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations A 2 [Pa] [in H O] Curves 1200 n [rpm] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 2165 1.85 6.60 83 — A 2 2165 2.33 8.70 81 51 A 3 2165 2.59 9.80 78 68 A 4 2165 2.57 9.80 79 64 A 5 1900 1.25 4.30 79 — A 6 1900 1.59 5.90 77 52 A 7 1900 1.74 6.60 75 68 A 8 1900 1.74 6.60 75 64 A 9 1600 0.75 2.60 71 — A 10 1600 0.95 3.50 72 52 A 11 1600 1.04 3.90 70 68 A 12 1600 1.04 3.90 71 64 1000 4,0 4 8 3 3,0 800 7 600 2,0 12 11 2 400 1,0 6 10 200 0 1000 2000 368 2000 9 4000 3000 4000 6000 5 5000 8000 1 [CFM] [m3/h] 21.0 AC centrifugal, backward General information R3G 450-AT14 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63045-2-4013 K3G 450-AT14 -20 36.5 K3G 450-AT14 -13 38.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 369 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 450 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 2165 2.63 4.90 -25 to +50 M) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations A 2 [Pa] [in H O] Curves 1200 n [rpm] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 2165 1.85 3.30 83 — A 2 2165 2.33 4.40 81 51 A 3 2165 2.59 4.90 78 68 A 4 2165 2.57 4.90 79 64 A 5 1900 1.25 2.20 79 — A 6 1900 1.59 3.00 77 52 A 7 1900 1.74 3.30 75 68 A 8 1900 1.74 3.30 75 64 A 9 1600 0.75 1.30 71 — A 10 1600 0.95 1.80 72 52 A 11 1600 1.04 2.00 70 68 A 12 1600 1.04 2.00 71 64 1000 4,0 4 8 3 3,0 800 7 600 2,0 12 11 2 400 1,0 6 10 200 0 1000 2000 370 2000 9 4000 3000 4000 6000 5 5000 8000 1 [CFM] [m3/h] 21.0 AC centrifugal, backward General information R3G 450-AT09 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63045-2-4013 K3G 450-AT09 -10 36.5 K3G 450-AT09 -03 38.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 371 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fan backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 605 50/60 810 265 1.60 -25 to +40 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] 200 0,75 0,50 3 100 2 0,25 12 11 6 50 10 9 0 1000 1000 372 2000 3000 1 5 3000 2000 4000 5000 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 810 211 1.30 72 — 2 765 244 1.50 63 56 A 3 750 265 1.60 59 61 A 4 780 232 1.40 61 49 A 5 645 100 0.70 65 14 A 6 635 130 0.80 58 57 A 7 625 137 0.90 55 63 A 8 650 115 0.80 58 50 A 9 465 42 0.30 56 14 A 10 475 58 0.40 51 59 A 11 475 64 0.40 48 66 A 12 485 52 0.40 52 49 8 7 P1 [W] A 4 150 n [rpm] A A 1,00 250 [in H O] Curves General information Centrifugal fan kg Inlet nozzle (long) R3G 500-AR34 -71 8.8 63072-2-4013 EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 373 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 605 Contacts Technology Accessories Core-end sleeves EC centrifugal fans and modules backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1125 0.71 3.20 -25 to +60 L1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 300 1,25 350 200 8 0,75 250 1,00 3 2 0,50 12 6 100 0,25 11 10 50 9 0 1000 1000 374 2000 2000 3000 5 3000 4000 5000 1 4000 6000 7000 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1125 0.54 2.40 81 — A 2 1110 0.66 3.00 74 59 A 3 1100 0.71 3.20 70 69 A 4 1110 0.69 3.10 70 66 A 5 920 0.29 1.30 75 — A 6 905 0.35 1.60 69 64 A 7 900 0.37 1.60 68 75 A 8 900 0.36 1.60 68 75 A 9 665 0.12 0.60 66 — A 10 650 0.12 0.70 60 65 A 11 650 0.13 0.70 58 78 A 12 655 0.14 0.70 57 82 7 150 P1 [kW] A A 4 n [rpm] General information AC centrifugal, backward AC centrifugal, forward Centrifugal module with support plate kg 63072-2-4013 K3G 500-AF32 -12 24.3 K3G 500-AF32 -11 28.0 EC centrifugal, backward EC-SYSTEMS EC centrifugal, forward kg Depth of screw 12-16 mm Cable gland Accessories 13.5 Centrifugal module w. support bracket Technology R3G 500-AF32 -11 Inlet nozzle (long) 375 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts kg Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC centrifugal, backward for clean rooms Mass of centrifugal module with support bracket Mass of centrifugal fan Centrifugal fan • • • • • Mass of centrifugal module with support plate – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC centrifugal fans and modules backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1160 0.82 2.90 -25 to +60 L2) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations 2 [Pa] [in H O] Curves 1,5 3 1,0 8 7 200 2 12 0,5 6 11 100 10 0 1000 1000 376 2000 9 3000 2000 3000 4000 5000 5 4000 6000 7000 1 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1160 0.57 2.10 83 — A 2 1160 0.74 2.60 75 58 A 3 1160 0.82 2.90 72 69 A 4 1160 0.76 2.70 71 66 A 5 1005 0.36 1.50 78 — A 6 980 0.43 1.70 71 63 A 7 970 0.45 1.80 68 76 A 8 980 0.43 1.70 67 70 A 9 735 0.15 0.70 69 — A 10 725 0.18 0.80 62 69 A 11 720 0.20 0.90 60 82 A 12 720 0.19 0.80 59 76 400 300 P1 [kW] A A 4 n [rpm] General information AC centrifugal, backward AC centrifugal, forward Centrifugal module with support plate kg 63072-2-4013 K3G 500-AF39 -07 24.3 K3G 500-AF39 -06 28.0 EC centrifugal, backward EC-SYSTEMS EC centrifugal, forward kg Depth of screw 12-16 mm Cable gland Accessories 13.5 Centrifugal module w. support bracket Technology R3G 500-AF39 -06 Inlet nozzle (long) 377 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC centrifugal, backward for clean rooms Mass of centrifugal module with support bracket Mass of centrifugal fan Centrifugal fan • • • • • Mass of centrifugal module with support plate – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC centrifugal fans and modules backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 1160 0.82 1.50 -25 to +60 L2) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 2 [Pa] [in H O] Curves 1,5 3 1,0 8 7 200 2 12 0,5 6 11 100 10 0 1000 1000 378 2000 9 3000 2000 3000 4000 5000 5 4000 6000 7000 1 [CFM] [m3/h] I [A] LwA [dB(A)] tL [%] 1 1160 0.57 1.10 83 — A 2 1160 0.74 1.30 75 58 A 3 1160 0.82 1.50 72 69 A 4 1160 0.76 1.40 71 66 A 5 1005 0.36 0.70 78 — A 6 980 0.43 0.90 71 63 A 7 970 0.45 0.90 68 76 A 8 980 0.43 0.80 67 70 A 9 735 0.15 0.40 69 — A 10 725 0.18 0.40 62 69 A 11 720 0.20 0.40 60 82 A 12 720 0.19 0.40 59 76 400 300 P1 [kW] A A 4 n [rpm] General information AC centrifugal, backward AC centrifugal, forward Centrifugal module with support plate kg 63072-2-4013 K3G 500-AF34 -02 24.3 K3G 500-AF34 -01 28.0 EC centrifugal, backward EC-SYSTEMS EC centrifugal, forward kg Depth of screw 12-16 mm Cable gland Accessories 13.5 Centrifugal module w. support bracket Technology R3G 500-AF34 -01 Inlet nozzle (long) 379 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start EC centrifugal, backward for clean rooms Mass of centrifugal module with support bracket Mass of centrifugal fan Centrifugal fan • • • • • Mass of centrifugal module with support plate – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC centrifugal fans and modules backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1700 2.80 8.50 -25 to +50 M) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations [Pa] Curves 4,0 1000 A 3,0 3 8 600 2,0 7 2 400 6 12 1,0 11 200 10 9 0 1000 2000 380 2000 4000 3000 4000 6000 5 5000 8000 1 6000 10000 [CFM] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1700 1.85 5.80 82 — A 2 1700 2.50 7.80 79 57 A 3 1700 2.65 8.20 78 65 A 4 1700 2.40 7.20 77 58 A 5 1500 1.30 4.20 78 — A 6 1500 1.70 5.20 75 60 A 7 1500 1.75 5.40 74 65 A 8 1500 1.65 5.20 74 61 A 9 1100 0.57 2.20 69 — A 10 1100 0.70 2.60 67 56 A 11 1100 0.75 2.60 66 63 A 12 1100 0.70 2.60 65 56 4 800 n [rpm] 22.0 AC centrifugal, backward General information R3G 500-AG10 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63072-2-4013 K3G 500-AG10 -20 38.5 K3G 500-AG10 -13 41.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 381 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 500 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 500 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1700 2.70 4.30 -25 to +60 M) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations [Pa] Curves 4,0 1000 A 3,0 3 8 600 2,0 7 2 400 6 12 1,0 11 200 10 9 0 1000 2000 382 2000 4000 3000 4000 6000 5 5000 8000 1 6000 10000 [CFM] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1700 1.85 2.90 82 — A 2 1700 2.50 3.90 79 57 A 3 1700 2.65 4.10 78 65 A 4 1700 2.40 3.60 77 58 A 5 1500 1.30 2.10 78 — A 6 1500 1.70 2.60 75 60 A 7 1500 1.75 2.70 74 65 A 8 1500 1.65 2.60 74 61 A 9 1100 0.57 1.10 69 — A 10 1100 0.70 1.30 67 56 A 11 1100 0.75 1.30 66 63 A 12 1100 0.70 1.30 65 56 4 800 n [rpm] 22.0 AC centrifugal, backward General information R3G 500-AG06 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63072-2-4013 K3G 500-AG06 -10 38.5 K3G 500-AG06 -03 41.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 383 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fan backward curved, 3-D, Ø 560 Electr. connection A Perm. amb. temp. M3G 112-GA Max. current draw (1) *3G 560 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 945 0.79 3.50 -25 to +60 L1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 1,25 300 4 200 8 0,75 250 1,00 3 0,50 100 6 12 0,25 11 50 10 9 0 1000 2000 384 2000 5 4000 3000 4000 6000 1 [CFM] 8000 [m3/h] I [A] LwA [dB(A)] tL [%] 1 945 0.47 2.20 74 — A 2 945 0.69 3.10 71 70 A 3 945 0.79 3.50 70 74 A 4 945 0.71 3.20 71 66 A 5 760 0.24 1.20 69 46 A 6 735 0.31 1.40 67 77 A 7 725 0.34 1.60 68 81 A 8 740 0.31 1.40 64 64 A 9 520 0.09 0.50 72 50 A 10 505 0.11 0.60 60 82 A 11 500 0.12 0.60 54 85 A 12 505 0.11 0.60 54 71 2 7 150 P1 [kW] A A 350 n [rpm] General information Mass of centrifugal fan EC centrifugal, backward for clean rooms EC centrifugal, forward 63071-2-4013 EC-SYSTEMS 13.9 Depth of screw 12-16 mm Cable gland Accessories R3G 560-AK32 -11 Inlet nozzle (long) Technology kg 385 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Centrifugal fan AC centrifugal, backward Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • EC centrifugal, backward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC centrifugal fans and modules backward curved, 3-D, Ø 560 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 560 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1350 2.30 7.00 -25 to +55 M) 3~ 200-240 A (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations A 2 [Pa] [in H O] Curves 3,0 800 2,5 600 400 3 7 1,5 500 2,0 8 12 300 1,0 2 6 11 200 0,5 10 100 9 0 2000 3000 386 5 4000 6000 1 6000 9000 [CFM] 12000 [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1350 1.33 4.40 78 — A 2 1350 1.90 5.80 77 60 A 3 1350 2.15 6.80 74 68 A 4 1350 2.10 4.40 74 63 A 5 1200 0.90 3.20 75 — A 6 1200 1.30 4.20 73 60 A 7 1200 1.55 5.00 71 68 A 8 1200 1.43 4.60 71 62 A 9 910 0.45 1.80 67 — A 10 910 0.60 2.20 65 60 A 11 910 0.70 2.40 64 65 A 12 910 0.65 2.40 64 63 4 700 n [rpm] 23.5 AC centrifugal, backward General information R3G 560-AG11 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63071-2-4013 K3G 560-AG11 -20 45.5 K3G 560-AG11 -13 48.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 387 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 560 Perm. amb. temp. Electr. connection M3G 150-FF Max. current draw (1) *3G 560 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1350 2.30 3.60 -25 to +60 M) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations A 2 [Pa] [in H O] Curves 3,0 800 2,5 600 400 3 7 1,5 500 2,0 8 12 300 1,0 2 6 11 200 0,5 10 100 9 0 2000 3000 388 5 4000 6000 1 6000 9000 [CFM] 12000 [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1350 1.33 2.20 78 — A 2 1350 1.90 2.90 77 60 A 3 1350 2.15 3.40 74 68 A 4 1350 2.10 2.20 74 63 A 5 1200 0.90 1.60 75 — A 6 1200 1.30 2.10 73 60 A 7 1200 1.55 2.50 71 68 A 8 1200 1.43 2.30 71 62 A 9 910 0.45 0.90 67 — A 10 910 0.60 1.10 65 60 A 11 910 0.70 1.20 64 65 A 12 910 0.65 1.20 64 63 4 700 n [rpm] 23.5 AC centrifugal, backward General information R3G 560-AG07 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63071-2-4013 K3G 560-AG07 -10 45.5 K3G 560-AG07 -03 48.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 389 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 560 Electr. connection A Perm. amb. temp. M3G 150-IF Max. current draw (1) *3G 560 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1510 2.90 9.20 -25 to +45 M) 3~ 200-240 (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations 2 4,0 [Pa] A 3,5 1000 [in H O] Curves 4 2,5 3,0 800 600 2,0 7 1,5 400 2 1,0 12 6 11 0,5 200 10 9 0 2000 4000 390 4000 1 5 6000 8000 8000 12000 [CFM] [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1510 1.90 6.00 81 — A 2 1510 2.47 7.60 80 52 A 3 1510 3.05 9.20 77 67 A 4 1510 2.85 8.80 76 64 A 5 1200 0.90 3.20 75 — A 6 1200 1.30 4.20 73 60 A 7 1200 1.55 5.00 71 68 A 8 1200 1.43 4.60 71 62 A 9 910 0.45 1.80 67 — A 10 910 0.60 2.20 65 60 A 11 910 0.70 2.40 64 65 A 12 910 0.65 2.40 64 63 3 8 n [rpm] 27.5 AC centrifugal, backward General information R3G 560-AH07 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63071-2-4013 K3G 560-AH07 -20 49.5 K3G 560-AH07 -13 52.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 391 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 560 Electr. connection A Perm. amb. temp. M3G 150-IF Max. current draw (1) *3G 560 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 9 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1510 3.10 4.90 -25 to +60 M) 3~ 380-480 (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 2 4,0 [Pa] A 3,5 1000 [in H O] Curves 4 2,5 3,0 800 600 2,0 7 1,5 400 2 1,0 12 6 11 0,5 200 10 9 0 2000 4000 392 4000 1 5 6000 8000 8000 12000 [CFM] [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1510 1.90 3.00 81 — A 2 1510 2.47 3.80 80 52 A 3 1510 3.05 4.60 77 67 A 4 1510 2.85 4.40 76 64 A 5 1200 0.90 1.60 75 — A 6 1200 1.30 2.10 73 60 A 7 1200 1.55 2.50 71 68 A 8 1200 1.43 2.30 71 62 A 9 910 0.45 0.90 67 — A 10 910 0.60 1.10 65 60 A 11 910 0.70 1.20 64 65 A 12 910 0.65 1.20 64 63 3 8 n [rpm] 27.5 AC centrifugal, backward General information R3G 560-AH02 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63071-2-4013 K3G 560-AH02 -10 49.5 K3G 560-AH02 -03 52.5 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 393 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fan backward curved, 3-D, Ø 630 Perm. amb. temp. Electr. connection M3G 112-GA Max. current draw (1) *3G 630 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 607 50/60 685 0.53 1.00 -25 to +60 L2) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations 2 [Pa] 4 0,75 200 3 150 0,50 8 7 100 2 0,25 12 6 11 50 10 9 0 1000 2000 394 2000 3000 4000 4000 6000 5 5000 8000 1 [CFM] [m3/h] n [rpm] P1 [kW] I [A] LwA [dB(A)] tL [%] A 1 685 0.38 0.70 73 — A 2 685 0.47 0.90 67 57 A 3 685 0.53 1.00 65 68 A 4 685 0.48 0.90 64 61 A 5 560 0.21 0.40 67 — A 6 545 0.23 0.50 61 61 A 7 540 0.26 0.50 59 71 A 8 550 0.24 0.50 58 65 A 9 390 0.08 0.20 56 — A 10 385 0.09 0.20 52 63 A 11 380 0.10 0.30 51 75 A 12 390 0.10 0.30 49 66 A 1,00 250 [in H O] Curves General information Mass of centrifugal fan EC centrifugal, backward for clean rooms EC centrifugal, forward 63070-2-4013 EC-SYSTEMS 14.7 Depth of screw 12-16 mm Cable gland Accessories R3G 630-AF36 -01 Inlet nozzle (long) Technology kg 395 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 607 Contacts Centrifugal fan AC centrifugal, backward Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • EC centrifugal, backward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, CCC, GOST are applied for EC centrifugal fans and modules backward curved, 3-D, Ø 630 Electr. connection A Perm. amb. temp. M3G 150-FF Max. current draw (1) *3G 630 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1000 1.70 5.30 -25 to +60 M) 3~ 200-240 (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations A 2 [Pa] [in H O] Curves 900 3,0 2,5 400 4 1,5 500 2,0 600 3 1,0 300 8 200 2 0,5 7 100 6 0 2000 4000 396 5 6000 4000 8000 1 8000 12000 10000 16000 [CFM] [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1000 1.10 3.60 74 — A 2 1000 1.40 4.60 71 54 A 3 1000 1.65 5.00 70 66 A 4 1000 1.70 5.20 70 64 A 5 770 0.50 2.00 66 — A 6 770 0.65 2.40 64 54 A 7 770 0.73 2.80 64 66 A 8 770 0.77 2.80 64 64 800 700 n [rpm] 24.5 AC centrifugal, backward General information R3G 630-AA12 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63070-2-4013 K3G 630-AA12 -20 47.5 K3G 630-AA12 -13 52.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 397 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 630 Electr. connection A Perm. amb. temp. M3G 150-FF Max. current draw (1) *3G 630 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1000 1.70 2.80 -25 to +60 M) 3~ 380-480 (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations A 2 [Pa] [in H O] Curves 900 3,0 2,5 400 4 1,5 500 2,0 600 3 1,0 300 8 200 2 0,5 7 100 6 0 2000 4000 398 5 6000 4000 8000 1 8000 12000 10000 16000 [CFM] [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1000 1.10 1.80 74 — A 2 1000 1.40 2.30 71 54 A 3 1000 1.65 2.50 70 66 A 4 1000 1.70 2.60 70 64 A 5 770 0.50 1.00 66 — A 6 770 0.65 1.20 64 54 A 7 770 0.73 1.40 64 66 A 8 770 0.77 1.40 64 64 800 700 n [rpm] 24.5 AC centrifugal, backward General information R3G 630-AA08 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63070-2-4013 K3G 630-AA08 -10 47.5 K3G 630-AA08 -03 52.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 399 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 630 Electr. connection A Perm. amb. temp. M3G 150-IF Max. current draw (1) *3G 630 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1200 2.80 8.40 -25 to +45 M) 3~ 200-240 (1) Nominal data in operating point with maximum load and 200 VAC subject to alterations A 2 [Pa] [in H O] Curves 900 3,0 2,5 600 2,0 8 7 12 1,0 300 2 11 200 6 0,5 10 100 9 0 2000 4000 400 4000 6000 8000 5 8000 12000 1 10000 16000 [CFM] [m3/h] LwA [dB(A)] tL [%] 1 1200 1.95 5.90 88 — 2 1200 2.44 7.40 83 52 A 3 1200 2.70 8.20 82 64 A 4 1200 2.80 8.40 82 64 A 5 1050 1.29 4.00 85 — A 6 1050 1.61 4.80 80 52 A 7 1050 1.78 5.40 79 64 A 8 1050 1.83 5.60 79 64 A 9 900 0.81 2.40 82 — A 10 900 1.01 3.00 77 52 A 11 900 1.12 3.40 75 64 A 12 900 1.15 3.40 75 64 3 1,5 400 I [A] A 4 500 P1 [kW] A 800 700 n [rpm] 28.5 AC centrifugal, backward General information R3G 630-AB10 -13 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63070-2-4013 K3G 630-AB10 -20 51.5 K3G 630-AB10 -13 56.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 401 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland EC centrifugal fans and modules backward curved, 3-D, Ø 630 Electr. connection A Perm. amb. temp. M3G 150-IF Max. current draw (1) *3G 630 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support bracket: Steel, coated in black Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 608 50/60 1200 2.80 4.20 -25 to +55 M) 3~ 380-480 (1) Nominal data in operating point with maximum load and 400 VAC subject to alterations A 2 [Pa] [in H O] Curves 900 3,0 2,5 600 2,0 8 7 12 1,0 300 2 11 200 6 0,5 10 100 9 0 2000 4000 402 4000 6000 8000 5 8000 12000 1 10000 16000 [CFM] [m3/h] LwA [dB(A)] tL [%] 1 1200 1.95 3.00 88 — 2 1200 2.44 3.70 83 52 A 3 1200 2.70 4.10 82 64 A 4 1200 2.80 4.20 82 64 A 5 1050 1.29 2.00 85 — A 6 1050 1.61 2.40 80 52 A 7 1050 1.78 2.70 79 64 A 8 1050 1.83 2.80 79 64 A 9 900 0.81 1.20 82 — A 10 900 1.01 1.50 77 52 A 11 900 1.12 1.70 75 64 A 12 900 1.15 1.70 75 64 3 1,5 400 I [A] A 4 500 P1 [kW] A 800 700 n [rpm] 28.5 AC centrifugal, backward General information R3G 630-AB06 -03 Inlet nozzle (long) Centrifugal module w. support bracket kg Centrifugal module with support plate kg 63070-2-4013 K3G 630-AB06 -10 51.5 K3G 630-AB06 -03 56.0 EC centrifugal, backward EC centrifugal, backward for clean rooms kg Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Mass of centrifugal module with support bracket – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST EC-SYSTEMS EC centrifugal, forward Depth of screw 20-25 mm 403 Inlet nozzle p. 550 f. Guard grille p. 553 Electr. connection p. 608 Contacts Technology Accessories Cable gland 404 Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Ø 310 - Ø 450 Technology EC centrifugal fans with aluminium impeller, line-fed 405 AC centrifugal, forward 406 Contacts AC centrifugal, backward General information EC centrifugal fans for clean rooms backward curved EC centrifugal fans and modules backward curved, 3-D, Ø 310, RS485, ebmBUS Perm. amb. temp. Electr. connection M3G 084-DF Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 2340 370 1.70 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 3,0 800 700 2,5 2,0 500 3 400 1,5 8 7 300 1,0 200 11 0,5 6 16 100 10 15 14 9 13 0 250 400 406 500 800 750 1200 1000 1600 1 [CFM] 5 1250 2000 2400 [m3/h] I [A] LpA [dB(A)] tL [%] 1 2340 265 1.20 74 — A 2 2270 335 1.50 71 63 A 3 2240 370 1.70 70 66 A 4 2290 335 1.50 70 48 A 5 1910 160 0.70 69 — A 6 1910 205 0.90 67 63 A 7 1910 240 1.00 66 66 A 8 1910 205 0.90 66 48 A 9 1410 80 0.40 61 — A 10 1410 98 0.40 59 63 A 11 1410 112 0.50 58 66 A 12 1410 103 0.50 57 48 A 13 910 40 0.20 50 — A 14 910 42 0.20 47 63 A 15 910 46 0.20 47 66 A 16 910 44 0.20 48 48 2 12 P1 [W] A 4 600 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module with support plate kg R3G 310-AJ38 -61 4.3 31050-2-4013 31051-2-4013 K3G 310-AJ38 -61 7.1 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) View Y View X (1) (2) N RSB in alarm mode = 0 V in alarm mode = +15 V RSA +15V(1) 0 V(2) 407 Inlet nozzle p. 550 f. Guard grille p. 553 Connection lead p. 559 Electr. connection p. 606 Contacts Technology Accessories PE L EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 310, RS485, ebmBUS Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 2200 455 2.00 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2,5 600 500 2,0 4 3 8 1,5 400 7 300 I [A] LpA [dB(A)] tL [%] 1 2200 345 1.50 73 — 2 2150 430 1.90 70 60 A 3 2130 455 2.00 68 64 A 4 2170 420 1.80 69 54 A 5 1800 200 0.90 68 — A 6 1800 265 1.20 65 60 A 7 1800 285 1.20 63 64 A 8 1800 260 1.10 64 54 A 9 1400 90 0.40 61 — A 10 1400 118 0.50 59 60 A 11 1400 128 0.60 57 64 A 12 1400 113 0.50 58 54 A 13 1000 33 0.10 52 — A 14 1000 44 0.20 48 60 A 15 1000 47 0.20 48 64 A 16 1000 41 0.20 49 54 1,0 2 12 200 6 0,5 11 16 100 10 15 14 13 0 500 500 408 P1 [W] A A 700 n [rpm] A 2 [Pa] [in H O] Curves (established with long inlet nozzle) 1000 9 1000 1500 2000 5 1500 2500 1 [CFM] 3000 [m3/h] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module with support plate kg R3G 310-AL28 -61 5.4 31050-2-4013 31051-2-4013 K3G 310-AL28 -61 8.2 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for Inlet nozzle (long) View Y View X (1) (2) N RSB in alarm mode = 0 V in alarm mode = +15 V RSA +15V(1) 0 V(2) 409 Inlet nozzle p. 550 f. Guard grille p. 553 Connection lead p. 559 Electr. connection p. 606 Contacts Technology Accessories PE L EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 355, RS485, ebmBUS Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 1840 430 1.90 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2,5 700 600 500 2,0 4 3 8 1,5 400 7 300 1,0 12 2 11 200 6 0,5 16 100 10 15 14 0 500 410 13 1000 500 1000 1500 1500 2000 1 5 9 2500 [CFM] 3000 [m3/h] n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1840 335 1.50 75 — A 2 1790 405 1.80 70 56 A 3 1770 430 1.90 66 70 A 4 1820 365 1.60 67 58 A 5 1540 200 0.90 70 — A 6 1540 256 1.10 66 56 A 7 1540 277 1.20 63 70 A 8 1540 235 1.00 63 58 A 9 1260 115 0.50 64 — A 10 1260 150 0.70 60 56 A 11 1260 159 0.70 56 70 A 12 1260 125 0.50 57 58 A 13 890 55 0.20 55 — A 14 890 67 0.30 52 56 A 15 890 70 0.30 49 70 A 16 890 59 0.30 49 58 A 2 [Pa] [in H O] Curves (established with long inlet nozzle) General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module with support plate kg R3G 355-AM14 -61 5.4 35560-2-4013 35561-2-4013 K3G 355-AM14 -61 8.7 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA; CCC, GOST are applied for Inlet nozzle (long) View X (1) (2) N RSB RSA +15V(1) 0 V(2) 411 Inlet nozzle p. 550 f. Connection lead p. 559 Electr. connection p. 606 Contacts Technology PE L in alarm mode = 0 V in alarm mode = +15 V Accessories View Y EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 355, RS485, ebmBUS Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 1710 395 1.80 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves (established with long inlet nozzle) 2,0 500 4 1,5 8 1,0 300 12 0,5 16 6 15 10 100 14 13 0 500 500 412 1000 1000 1500 2000 9 1500 2500 1 5 2000 3000 3500 [CFM] [m3/h] tL [%] 1710 305 1.30 72 — 2 1660 375 1.60 67 58 A 3 1650 395 1.80 64 68 A 4 1670 365 1.60 66 57 A 5 1400 166 0.70 65 — A 6 1400 225 1.00 63 58 A 7 1400 245 1.10 60 68 A 8 1400 216 0.90 61 57 A 9 1200 105 0.50 60 — A 10 1200 150 0.70 58 58 A 11 1200 172 0.80 56 68 A 12 1200 136 0.60 57 57 A 13 1000 60 0.30 55 — A 14 1000 82 0.40 53 58 A 15 1000 90 0.40 51 68 A 16 1000 80 0.40 53 57 2 11 LpA [dB(A)] 1 7 200 I [A] A 400 3 P1 [W] A A 600 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Inlet nozzle (short) Centrifugal module with support plate kg R3G 355-AN31 -61 5.5 35560-2-4013 35561-2-4013 K3G 355-AN31 -61 8.9 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: VDE, UL, CSA; CCC, GOST are applied for Inlet nozzle (long) View X (1) (2) N RSB RSA +15V(1) 0 V(2) 413 Inlet nozzle p. 550 f. Connection lead p. 559 Electr. connection p. 606 Contacts Technology PE L in alarm mode = 0 V in alarm mode = +15 V Accessories View Y EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 400, RS485 ebmBUS Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 1470 370 1.65 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 2 [Pa] [in H O] Curves 2,0 500 4 1,5 3 1,0 300 7 200 12 0,5 2 11 6 100 10 9 0 500 500 414 1000 1000 1500 5 1500 2000 2500 3000 1 2000 3500 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1470 323 1.45 73 — A 2 1430 362 1.60 69 53 A 3 1420 370 1.65 64 68 A 4 1470 319 1.40 66 52 A 5 1300 210 0.90 71 — A 6 1300 255 1.10 65 53 A 7 1300 270 1.20 61 68 A 8 1300 230 1.00 64 52 A 9 910 90 0.40 61 — A 10 910 100 0.40 57 53 A 11 910 108 0.50 53 68 A 12 910 92 0.40 51 52 400 8 P1 [W] A A 600 n [rpm] General information Centrifugal fan kg Inlet nozzle (long) Centrifugal module with support plate kg R3G 400-AD27 -61 5.8 54476-2-4013 K3G 400-AD27 -61 9.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for View X (1) (2) N RSB RSA +15V(1) 0 V(2) Connection lead p. 559 Electr. connection p. 606 415 Inlet nozzle p. 550 f. Guard grille p. 553 Contacts Technology PE L in alarm mode = 0 V in alarm mode = +15 V Accessories View Y EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 400, RS485 ebmBUS Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) *3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Sheet aluminium, spacer profiles: Aluminium Impeller: Sheet aluminium, joined by tabs Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A °C p. 606 50/60 1420 380 1.70 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations 500 2,0 600 4 n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1420 327 1.45 73 — A 2 1395 355 1.55 71 40 A 3 1370 380 1.70 66 64 A 4 1415 333 1.45 69 54 A 5 1120 187 0.80 68 — A 6 1120 207 0.90 65 40 A 7 1120 225 1.00 60 64 A 8 1120 173 0.80 61 54 A 9 800 85 0.40 60 — A 10 800 92 0.40 58 40 A 11 800 97 0.40 53 64 A 12 800 85 0.40 54 54 A 2 [Pa] [in H O] Curves 1,5 400 3 300 1,0 8 7 200 0,5 12 2 11 100 6 10 500 500 416 1000 1000 1500 1500 2000 1 5 9 0 2500 2000 3000 3500 [CFM] [m3/h] General information Centrifugal fan kg Inlet nozzle (long) Centrifugal module with support plate kg R3G 400-AC30 -61 5.9 54476-2-4013 K3G 400-AC30 -61 9.9 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal module with support plate AC centrifugal, forward AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; VDE, CCC, GOST are applied for View X (1) (2) N RSB RSA +15V(1) 0 V(2) Connection lead p. 559 Electr. connection p. 606 417 Inlet nozzle p. 550 f. Guard grille p. 553 Contacts Technology PE L in alarm mode = 0 V in alarm mode = +15 V Accessories View Y EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm EC centrifugal fans and modules backward curved, 3-D, Ø 450, RS485, ebmBUS Perm. amb. temp. Electr. connection M3G 112-EA Max. current draw (1) *3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Support plate: Galvanised sheet steel, spacer profiles: Aluminium Impeller: Sheet aluminium, laser-welded Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Number of blades: 6 – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 20 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A °C p. 606 50/60 1225 0.50 2.20 -25 to +40 K2) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC subject to alterations A 2 [Pa] [in H O] Curves 400 4 P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1225 0.35 1.50 68 — A 2 1225 0.49 2.10 64 65 A 3 1225 0.50 2.20 64 67 A 4 1225 0.47 2.10 63 62 A 5 1000 0.19 0.80 63 — A 6 1000 0.26 1.20 59 65 A 7 1000 0.28 1.20 59 67 A 8 1000 0.26 1.10 57 62 A 9 700 0.07 0.30 55 — A 10 700 0.09 0.40 49 65 A 11 700 0.10 0.40 49 67 A 12 700 0.09 0.40 48 62 3 1,2 300 n [rpm] 8 7 0,8 200 2 6 100 0,4 12 11 10 5 9 0 1000 1000 418 2000 2000 3000 1 3000 4000 5000 [CFM] [m3/h] General information 11.5 Centrifugal module with support plate kg 63045-2-4013 K3G 450-AO51 -01 25.4 AC centrifugal, forward EC centrifugal, backward for clean rooms R3G 450-AO51 -01 Inlet nozzle (long) Depth of screw 12-16 mm View X (1) (2) PE L 15 N RSB RSA +15V(1) 0 V(2) Connection lead p. 559 Electr. connection p. 606 630-1 500-1 Technology 8xØ11 Ø284,5 4xØ9 15 580±0,5 419 Inlet nozzle p. 550 f. Guard grille p. 553 Contacts 360 120 2,5 30 353,5 294,5 in alarm mode = 0 V in alarm mode = +15 V Accessories View Y EC-SYSTEMS EC centrifugal, forward kg EC centrifugal, backward Mass of centrifugal module with support plate Mass of centrifugal fan Centrifugal fan AC centrifugal, backward – Technical features: • Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA) • PFC (active) • Over-temperature protected electronics / motor • RS485 ebmBUS – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Electrical connection: Via connection lead with plug (accessory) – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, VDE, CCC, GOST are applied for 420 General information 422 EC centrifugal fans and blowers, single inlet, line-fed Ø 108 - Ø 450 438 EC centrifugal blowers, dual inlet, 24 / 48 VDC Ø 133 - Ø 160 502 EC centrifugal blowers, dual inlet, line-fed Ø 146 - Ø 180 510 AC centrifugal, backward Ø 085 - Ø 160 421 Contacts Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward EC centrifugal fans and blowers, single inlet, 24 / 48 VDC AC centrifugal, forward EC centrifugal fans and blowers forward curved EC centrifugal fans and blowers single inlet, Ø 085 M1G 045-BE A 48 rpm W A dB(A) 16-28 95 2850 14 0.64 57 36-57 95 2850 14 0.32 57 Electr. connection *1G 085 m3/h Perm. amb. temp. 24 VDC Min. back pressure A Sound pressure level M1G 045-BE Current draw *1G 085 Power input Motor Speed/rpm Type Air flow Nominal data Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 240 UR 4' 0,8 200 4 0,6 UN 3' 0,4 3 80 8 0,2 2' 2 7 40 6 1 5 0 10 20 20 422 30 40 40 60 50 80 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 3180 19 59 — A 2’ 3300 16 57 28 A 3’ 3500 15 57 32 A 4’ 3800 12 57 37 A 1 2850 14 57 — A 2 3000 12 55 28 A 3 3180 11 55 32 A 4 3400 9 54 37 A 5 1890 5 46 — A 6 1970 4 44 25 A 7 2070 4 44 30 A 8 2170 3 42 33 160 120 n [rpm] General information AC centrifugal, backward • Tach output • Reverse polarity and locked-rotor protection Centrifugal fan kg Centrifugal blower with flange kg R1G 085-AB05 -01 0.5 G1G 085-AB05 -01 0.8 R1G 085-AB07 -01 0.5 G1G 085-AB07 -01 0.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – Technical features: • Control input 0-10 VDC / PWM – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (48 VDC) CCC Depth of screw max. 4 mm 68 ±1 EC centrifugal, forward 45,4 ±1 EC-SYSTEMS Ø34 6 Ø67 Ø85 Ø59 M4 60 300±20 42 47±0,15 Brass lead tips 76 117,5 3 56 20˚ 127,5 Technology M4 71,5 84 Ø65 -1 39 68 3x1 42 6 60 80 300 423 Inlet nozzle p. 552 Guard grille p. 554 Electr. connection p. 600 Contacts 58 34,5 4,5 5,5 Accessories 60,2 66 EC centrifugal fans and blowers single inlet, Ø 097 M1G 045-BE A 48 rpm W A dB(A) 16-28 95 2650 16 0.75 59 36-57 95 2650 16 0.38 59 Electr. connection *1G 097 m3/h Perm. amb. temp. 24 VDC Min. back pressure A Sound pressure level M1G 045-BE Current draw *1G 097 Power input Motor Speed/rpm Type Air flow Nominal data Voltage range VDC Curve Nominal voltage – Material: Housing: Hot-dip galvanised sheet steel Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 4' 280 1,0 UR 4 200 0,8 240 3' 0,6 160 UN 3 0,4 120 80 8 0,2 2' 7 2 40 6 1 5 0 10 20 424 20 40 30 40 60 50 80 1' 60 100 [CFM] [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 2920 22 62 — A 2’ 3030 21 61 41 A 3’ 3300 17 59 48 A 4’ 3700 13 58 48 A 1 2650 16 59 — A 2 2730 15 58 41 A 3 2960 13 56 48 A 4 3290 10 55 48 A 5 1615 4 45 — A 6 1650 4 45 38 A 7 1745 4 43 46 A 8 1880 3 42 47 General information AC centrifugal, backward • Tach output • Reverse polarity and locked-rotor protection Centrifugal fan kg Centrifugal blower without flange kg R1G 097-AA05 -01 0.5 G1G 097-AA05 -01 0.8 R1G 097-AA07 -01 0.5 G1G 097-AA07 -01 0.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward – Technical features: • Control input 0-10 VDC / PWM – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (48 VDC) CCC Depth of screw max. 4 mm 33 ±1 EC centrifugal, forward 49,4 ±1 EC-SYSTEMS Ø34 Ø59 6 Ø77,5 Ø97 M4 60 300±20 25 47±0,15 Brass lead tips Accessories 143 75 18 24 3 ,5˚ 137 3x1 60 20˚ Ø96 Ø80 6 Technology 75 46 56 3 300 425 Inlet nozzle p. 552 Guard grille p. 554 Electr. connection p. 600 Contacts 40 EC centrifugal fans and blowers single inlet, Ø 108 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 108 M1G 055-BD A 24 16-28 200 3000 42 2.00 65 *1G 108 M1G 055-BD A 48 36-57 200 3000 42 1.00 65 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 1,5 400 3' 1,0 UN 8 0,5 7 2' 100 2 6 5 0 20 40 426 40 60 80 80 120 100 140 1 120 180 1' [CFM] [m3/h] tL [%] 1’ 3230 55 67 — 2’ 3410 52 66 33 A 3’ 3800 43 65 41 A 4’ 4100 35 64 33 A 1 3000 42 65 — A 2 3140 40 64 33 A 3 3420 32 63 41 A 4 3690 26 63 33 A 5 2300 20 61 — A 6 2380 17 58 33 A 7 2550 14 55 41 A 8 2720 11 55 33 3 200 LpA [dB(A)] A 4 300 P1 [W] A 4' UR n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R1G 108-AB17 -02 0.7 G1G 108-AB17 -02 1.4 R1G 108-AB41 -02 0.7 G1G 108-AB41 -02 1.4 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC Depth of screw max. 6 mm 63 ±1 EC centrifugal, forward 55 ±1 EC-SYSTEMS Ø58 6 Ø84 Ø108 Ø72 M4 85 450±20 52 58 ±0,15 Brass lead tips 159 115 97 118 6 Technology 183 50 66 76 Ø87-1 M4 85 71 450±20 82 427 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 600 Contacts 83 8 Accessories 79 EC centrifugal fans and blowers single inlet, Ø 120 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 120 M1G 055-BD A 24 16-28 255 2200 40 1.90 62 *1G 120 M1G 055-BD A 48 36-57 255 2200 40 0.95 62 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves UR 400 1,5 4 1,0 UN 3' 200 3 8 0,5 7 2' 100 2 6 5 0 50 40 428 80 1 150 100 120 160 200 240 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 2410 50 63 — A 2’ 2620 47 62 58 A 3’ 2870 44 61 60 A 4’ 3200 36 62 55 A 1 2200 40 62 — A 2 2410 36 60 59 A 3 2600 32 58 62 A 4 2880 25 58 55 A 5 1870 24 55 — A 6 1990 21 54 58 A 7 2100 18 53 61 A 8 2310 14 54 54 4' 300 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R1G 120-AB67 -02 0.8 G1G 120-AB67 -02 1.6 R1G 120-AB71 -02 0.8 G1G 120-AB71 -02 1.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC Depth of screw max. 6 mm 83 ±1 EC centrifugal, forward 55±1 EC-SYSTEMS Ø58 6 Ø97 Ø120 Ø72 M4 85 450±20 62 58 ±0,15 Brass lead tips 178 115 190 98 50 68 76 Technology 132 Ø100 -1 82 M4 86 6 85 98 450 ±20 429 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 600 Contacts 83 7 Accessories 82 100 EC centrifugal fans and blowers single inlet, Ø 133 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 133 M1G 055-BD A 24 16-28 225 2000 40 2.20 64 *1G 133 M1G 055-BD A 48 36-57 225 2000 45 1.10 64 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Hot-dip galvanised sheet steel Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 4' 1,5 400 4 UR 3' UN 300 1,0 3 8 200 7 2' 0,5 2 6 100 5 0 40 40 430 80 80 120 1 1' 120 160 200 [CFM] 240 [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 2170 57 66 — A 2’ 2410 51 66 47 A 3’ 2750 44 64 49 A 4’ 3200 36 66 32 A 1 2000 45 64 — A 2 2230 40 64 49 A 3 2540 35 62 51 A 4 2920 27 63 33 A 5 1750 28 60 — A 6 1910 24 59 50 A 7 2120 20 58 53 A 8 2370 15 59 35 General information Centrifugal fan kg Centrifugal blower without flange kg R1G 133-AE19 -02 0.7 G1G 133-DE19 -02 1.3 R1G 133-AE03 -02 0.7 G1G 133-DE03 -02 1.3 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Lateral – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC Depth of screw max. 6 mm 66 ±1 EC centrifugal, forward 55±1 EC-SYSTEMS Ø58 6 Ø108 Ø133 Ø72 M4 85 450±20 46 58 ±0,15 Brass lead tips 171 59 Accessories 87 101 Technology Ø112 180 45˚ 3 71 4x90˚ 431 Inlet nozzle p. 552 Electr. connection p. 600 Contacts 81 6 85 450±20 140 EC centrifugal fans and blowers single inlet, Ø 140 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 140 M1G 055-CF A 24 16-28 400 1750 54 2.50 63 *1G 140 M1G 055-CF A 48 36-57 410 1750 54 1.30 63 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 22 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 1,5 300 1,0 3' UR 3 200 8 7 0,5 2' 2 100 6 0 50 100 432 100 5 200 150 200 300 1 400 1' 250 [CFM] [m3/h] LpA [dB(A)] tL [%] 1’ 1850 65 64 — A 2’ 2020 61 61 50 A 3’ 2200 57 59 54 A 4’ 2550 43 60 40 A 1 1750 54 63 — A 2 1900 50 59 51 A 3 2030 45 58 54 A 4 2310 32 58 40 A 5 1500 34 60 — A 6 1580 29 56 50 A 7 1670 25 54 53 A 8 1880 19 53 41 4 UN P1 [W] A 400 4' n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R1G 140-AV17 -02 1.0 G1G 140-AV17 -02 2.3 R1G 140-AV21 -02 1.0 G1G 140-AV21 -02 2.3 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: A (48 VDC) CCC Depth of screw max. 6 mm 72 ±1 EC centrifugal, forward 68,2 ±1 EC-SYSTEMS Ø58 6 Ø121 Ø140 Ø72 M4 85 450±20 59 58 ±0,15 Brass lead tips max. 227,8 Accessories 6,6 103 158 107 M4 6 Technology 450±20 max. 262,6 92 105 94 Ø118-1 85 100 ±1 433 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 600 Contacts 120 130 115 EC centrifugal fans and blowers single inlet, Ø 146 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 146 M1G 074-BF A 24 16-28 470 2200 100 5.00 68 *1G 146 M1G 074-BF A 48 36-57 465 2150 100 2.60 67 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 A 3,0 [Pa] [in H O] Curves (established at 24 VDC) 2,5 700 4' 600 400 2,0 UN 3 8 300 1,0 2 12 6 0,5 11 10 100 50 100 434 100 150 200 200 300 1 5 9 0 LpA [dB(A)] tL [%] 1’ 2400 140 70 — A 2’ 2650 130 67 45 A 3’ 3000 110 66 49 A 4’ 3300 100 67 45 A 1 2200 100 68 — A 2 2445 90 65 46 A 3 2750 84 64 49 A 4 3025 77 65 45 A 5 1890 68 63 — A 6 2075 57 60 46 A 7 2250 48 61 49 A 8 2335 41 61 45 A 9 1520 37 59 — A 10 1670 32 55 46 A 11 1815 27 55 49 A 12 1920 23 55 45 2' 7 200 P1 [W] A 3' 1,5 500 UR 4 n [rpm] 250 400 1' 300 500 [CFM] [m3/h] General information Centrifugal fan kg Centrifugal blower with flange kg R1G 146-AA07 -52 1.4 G1G 146-BA07 -52 2.8 R1G 146-AA11 -52 1.4 G1G 146-BA11 -52 2.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA, CCC (centrifugal blower only) EC centrifugal, forward Depth of screw max. 6 mm 72 ±1 65 ±1 EC-SYSTEMS 6 32,7 Ø92 min. Ø119,5 max. Ø146,5 58 ± 0, 15 M4 85 450 +20 max. 62,5 Brass lead tips 450 +20 Accessories 158 108 M4 6 Technology 6,3 103 max. 262,6 Ø125,5-1 max. 227,8 92 94 105 85 100 ±1 435 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 600 Contacts 120 130 115 EC centrifugal fans and blowers single inlet, Ø 160 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) *1G 160 M1G 074-BF A 24 16-28 505 1750 105 5.80 67 *1G 160 M1G 074-BF A 48 36-57 505 1750 105 2.90 67 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 900 3,0 4' UR 600 2,0 4 500 3' UN 400 3 8 7 300 1,0 2' 2 200 6 100 5 0 100 100 436 200 200 300 400 1 300 500 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 1890 134 68 — A 2’ 2200 118 67 52 A 3’ 2500 110 67 57 A 4’ 2900 102 69 52 A 1 1750 105 67 — A 2 2030 95 66 52 A 3 2270 90 65 57 A 4 2550 81 67 44 A 5 1580 72 62 — A 6 1810 66 62 52 A 7 2000 58 62 57 A 8 2200 48 63 54 800 700 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R1G 160-AH29 -52 1.4 G1G 160-BH29 -52 2.8 R1G 160-AH39 -52 1.4 G1G 160-BH39 -52 2.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Axial – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA EC centrifugal, forward Depth of screw max. 6 mm 72 ±1 65 ±1 EC-SYSTEMS 6 32,7 Ø92 min. Ø136 max. Ø160,5 58 ± 0, 15 M4 85 450 +20 max. 62 Brass lead tips max. 227,8 130 175 108 M4 6 Technology max. 262,6 450 +20 Ø130 -1 Accessories 6,3 103 92 94 105 85 100 ±1 437 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 600 Contacts 120 115 EC centrifugal fan and blowers single inlet, Ø 108 Max. current draw (1) Motor Hz rpm W A *3G 108 M3G 055-BD 50/60 2960 60 0.90 subject to alterations 1~ 115 A Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 115 VAC A 2 [Pa] [in H O] Curves n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2960 60 0.90 64 — A 2 3100 53 0.80 62 42 A 3 3370 42 0.60 60 44 A 4 3560 34 0.50 59 32 A 5 2570 38 0.55 61 — A 6 2660 34 0.50 60 42 A 7 2820 25 0.40 57 44 A 8 2920 19 0.30 55 32 A 9 2150 23 0.35 56 — A 10 2200 20 0.30 55 42 A 11 2320 16 0.25 52 44 A 12 2390 12 0.20 50 32 A 13 1400 9 0.20 46 — A 14 1425 8 0.20 44 42 A 15 1490 7 0.20 40 44 A 16 1530 6 0.20 40 32 1,5 400 4 300 1,0 3 8 200 7 0,5 12 11 2 100 6 16 10 15 14 9 13 0 25 40 438 50 80 75 120 5 100 160 1 150 125 200 240 [CFM] [m3/h] General information Centrifugal fan kg Centrifugal blower with flange R3G 108-AB15 -02 1.0 G3G 108-BB15 -02 EC centrifugal, backward kg EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for 1.7 EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 183 168,5 71 450+20 439 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 6 85 Technology Ø118 M4 82 110,5 Accessories 8 79 50 76 159 Ø87-1 83 66 115 97 EC centrifugal fan and blowers single inlet, Ø 108 Max. current draw (1) Motor Hz rpm W A *3G 108 M3G 055-BD 50/60 2800 50 0.38 subject to alterations 1~ 230 A Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 230 VAC A 2 [Pa] [in H O] Curves 300 1,0 4 200 0,5 11 100 2 6 16 10 15 14 9 13 0 25 40 440 50 80 75 120 5 100 160 1 125 200 150 240 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 2800 50 0.38 64 — A 2 2950 44 0.35 62 42 A 3 3120 33 0.25 60 44 A 4 3260 25 0.20 59 32 A 5 2570 38 0.30 61 — A 6 2660 34 0.25 60 42 A 7 2820 25 0.20 57 44 A 8 2920 19 0.15 55 32 A 9 2150 23 0.20 56 — A 10 2200 20 0.15 55 42 A 11 2320 16 0.15 52 44 A 12 2390 12 0.10 50 32 A 13 1400 9 0.10 46 — A 14 1425 8 0.10 44 42 A 15 1490 7 0.10 40 44 A 16 1530 6 0.10 40 32 7 12 P1 [W] A 3 8 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 108-AB01 -02 1.0 G3G 108-BB01 -02 1.7 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 183 168,5 71 450+20 441 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 6 85 Technology Ø118 M4 82 110,5 Accessories 8 79 50 76 159 Ø87-1 83 66 115 97 EC centrifugal fan and blowers single inlet, Ø 120 Max. current draw (1) Motor Hz rpm W A *3G 120 M3G 055-BD 50/60 2320 46 0.70 1~ 115 A subject to alterations Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 115 VAC A 2 [Pa] [in H O] Curves 300 1,0 4 8 3 200 7 0,5 12 11 2 100 16 10 14 9 13 0 25 40 442 50 80 75 120 100 160 5 1 125 200 150 240 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2320 46 0.70 61 — A 2 2490 40 0.60 59 52 A 3 2640 33 0.50 58 58 A 4 2880 24 0.40 57 51 A 5 2060 34 0.50 59 — A 6 2190 29 0.45 57 50 A 7 2295 24 0.40 55 54 A 8 2445 18 0.30 54 52 A 9 1830 24 0.40 54 — A 10 1920 20 0.30 52 50 A 11 2010 17 0.30 51 54 A 12 2115 13 0.20 51 52 A 13 1430 13 0.20 48 — A 14 1500 12 0.20 45 50 A 15 1580 10 0.20 44 54 A 16 1640 8 0.20 44 52 6 15 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 120-AB13 -02 1.1 G3G 120-BB13 -02 1.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 115 100 Accessories 7 82 Ø132 82 82 86 450 +20 6 85 M4 Technology 190 Ø100-1 98 50 110 443 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 83 68 76 178 EC centrifugal fan and blowers single inlet, Ø 120 Max. current draw (1) Motor Hz rpm W A *3G 120 M3G 055-BD 50/60 2200 41 0.30 1~ 230 A subject to alterations Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 230 VAC A 2 [Pa] [in H O] Curves 1,0 300 4 8 200 7 0,5 11 100 16 2 10 14 9 13 0 25 40 444 50 80 75 120 100 160 5 1 125 200 150 240 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 2200 41 0.30 62 — A 2 2320 34 0.25 59 51 A 3 2440 28 0.20 57 55 A 4 2600 20 0.15 57 49 A 5 2060 34 0.25 59 — A 6 2190 29 0.20 57 50 A 7 2295 24 0.20 55 54 A 8 2445 18 0.15 54 52 A 9 1830 24 0.20 54 — A 10 1920 20 0.15 52 50 A 11 2010 17 0.15 51 54 A 12 2115 13 0.10 51 52 A 13 1430 13 0.10 48 — A 14 1500 12 0.10 45 50 A 15 1580 10 0.10 44 54 A 16 1640 8 0.10 44 52 6 15 P1 [W] A 3 12 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 120-AB03 -02 1.1 G3G 120-BB03 -02 1.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 115 100 Accessories 7 82 Ø132 82 82 86 450 +20 6 85 M4 Technology 190 Ø100-1 98 50 110 445 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 83 68 76 178 EC centrifugal fan and blowers single inlet, Ø 133 Max. current draw (1) Motor Hz rpm W A *3G 133 M3G 055-BD 50/60 2000 42 0.60 1~ 115 A subject to alterations Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Hot-dip galvanised sheet steel Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 115 VAC A 2 [Pa] [in H O] Curves 300 1,0 4 3 200 8 7 0,5 12 11 100 2 10 15 14 9 13 0 25 40 446 50 80 75 120 5 100 160 1 125 200 150 240 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2000 42 0.60 64 — A 2 2140 37 0.55 62 42 A 3 2310 30 0.45 60 52 A 4 2460 23 0.35 58 51 A 5 1780 30 0.45 60 — A 6 1870 26 0.40 59 45 A 7 1995 21 0.30 56 53 A 8 2120 17 0.25 56 51 A 9 1495 18 0.30 55 — A 10 1570 16 0.25 54 45 A 11 1640 13 0.20 51 53 A 12 1730 10 0.20 50 51 A 13 1100 9 0.20 49 — A 14 1140 8 0.20 47 45 A 15 1200 7 0.20 44 53 A 16 1250 6 0.20 41 51 6 16 n [rpm] General information Centrifugal fan kg Centrifugal blower without flange kg R3G 133-AD11 -02 1.0 G3G 133-DD11 -02 1.5 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 171 59 Accessories 87 4x90° 180 Ø112-1 71 45° Ø14 Technology 450 +20 79 447 Inlet nozzle p. 552 Electr. connection p. 601 Contacts 92,5 Ø3 6 85 0 EC centrifugal fan and blowers single inlet, Ø 133 Max. current draw (1) Motor Hz rpm W A *3G 133 M3G 055-BD 50/60 1925 38 0.30 1~ 230 A subject to alterations Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Hot-dip galvanised sheet steel Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 230 VAC A 2 [Pa] [in H O] Curves 1,0 300 4 200 8 0,5 12 11 100 2 10 15 14 9 13 0 25 40 448 50 80 75 120 5 100 160 200 1 125 150 240 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1925 38 0.30 63 — A 2 2070 34 0.25 62 45 A 3 2210 27 0.20 60 53 A 4 2330 21 0.15 59 51 A 5 1780 30 0.25 60 — A 6 1870 26 0.20 59 45 A 7 1995 21 0.15 56 53 A 8 2120 17 0.15 56 51 A 9 1495 18 0.15 55 — A 10 1570 16 0.15 54 45 A 11 1640 13 0.10 51 53 A 12 1730 10 0.10 50 51 A 13 1100 9 0.10 49 — A 14 1140 8 0.10 47 45 A 15 1200 7 0.10 44 53 A 16 1250 6 0.10 41 51 6 16 P1 [W] A 3 7 n [rpm] General information Centrifugal fan kg Centrifugal blower without flange kg R3G 133-AD05 -02 1.0 G3G 133-DD05 -02 1.5 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips 171 59 Accessories 87 4x90° 180 Ø112-1 71 45° Ø14 Technology 450 +20 79 449 Inlet nozzle p. 552 Electr. connection p. 601 Contacts 92,5 Ø3 6 85 0 EC centrifugal fan and blowers single inlet, Ø 140 Max. current draw (1) Motor Hz rpm W A *3G 140 M3G 055-CF 50/60 1790 70 1.00 subject to alterations 1~ 115 A Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 115 VAC 2 A 1,25 [Pa] [in H O] Curves 300 1,00 3 0,75 0,50 12 0,25 11 6 16 10 15 14 13 100 0 100 450 9 200 1 5 200 300 300 400 500 [CFM] [m3/h] LpA [dB(A)] tL [%] 1 1790 70 1.00 63 — 2 1900 63 1.00 61 46 A 3 2040 53 0.80 60 61 A 4 2250 36 0.50 58 55 A 5 1410 33 0.60 58 — A 6 1500 30 0.55 56 46 A 7 1600 25 0.45 54 56 A 8 1790 18 0.30 53 48 A 9 1060 14 0.35 51 — A 10 1105 13 0.30 50 46 A 11 1210 11 0.25 47 56 A 12 1355 8 0.20 47 48 A 13 705 4 0.20 40 — A 14 750 4 0.20 39 46 A 15 800 3 0.20 38 56 A 16 895 3 0.20 37 48 7 100 I [A] A 8 2 P1 [W] A 4 200 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 140-AV19 -02 1.3 G3G 140-AV19 -02 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips max. 227,8 6,6 Accessories 103 107 M4 Technology 247 Ø158 6 85 450 +20 max. 262,6 92 94 Ø118-1 100±1 16 451 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 120 105 130 115 EC centrifugal fan and blowers single inlet, Ø 140 Max. current draw (1) Motor Hz rpm W A *3G 140 M3G 055-CF 50/60 1800 66 0.50 subject to alterations 1~ 230 A Electr. connection Max. power input (1) Type Perm. amb. temp. Speed/rpm Nominal data Min. back pressure Frequency VAC Curve Nominal voltage – Material: Housing: Die-cast aluminium Impeller: Hot-dip galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 601 -25 to +60 H1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 A 1,25 [Pa] [in H O] Curves 300 1,00 4 200 0,75 3 0,50 2 0,25 11 6 16 10 15 14 13 100 0 100 452 9 200 1 5 200 300 300 400 500 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1800 66 0.50 63 — A 2 1860 58 0.40 62 46 A 3 1970 49 0.35 60 56 A 4 2170 33 0.25 58 48 A 5 1410 33 0.30 58 — A 6 1500 30 0.25 56 46 A 7 1600 25 0.25 54 56 A 8 1790 18 0.15 53 48 A 9 1060 14 0.15 51 — A 10 1105 13 0.15 50 46 A 11 1210 11 0.15 47 56 A 12 1355 8 0.10 47 48 A 13 705 4 0.10 40 — A 14 750 4 0.10 39 46 A 15 800 3 0.10 38 56 A 16 895 3 0.10 37 48 7 12 P1 [W] A 8 100 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 140-AV03 -02 1.3 G3G 140-AV03 -02 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Locked-rotor protection • Output 10 VDC max. 1.1 mA – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips max. 227,8 6,6 Accessories 103 107 M4 Technology 247 Ø158 6 85 450 +20 max. 262,6 92 94 Ø118-1 100±1 16 453 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 601 Contacts 120 105 130 115 EC centrifugal fan and blowers single inlet, constant air flow, Ø 140 subject to alterations rpm W A 50/60 1340 70 1.00 1~ 115 Electr. connection Hz Perm. amb. temp. A VAC Min. back pressure M3G 055-CF Max. current draw (1) *3G 140 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: PP plastic Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 602 -25 to +60 H2) 0 (1) Nominal data in operating point with maximum load and 115 VAC [Pa] Curves A 1,5 400 1 2 3 200 4 0,5 100 7 10 0 50 100 454 9 8 12 11 100 150 200 200 300 250 400 [CFM] I [A] LpA [dB(A)] tL [%] 1 2390 29 0.40 59 37 A 2 2450 55 0.80 60 50 A 3 2460 67 1.00 60 57 A 4 1920 17 0.30 54 38 A 5 1960 30 0.70 55 54 A 6 2130 55 0.80 60 55 A 7 1300 9 0.20 46 36 A 8 1550 22 0.30 51 48 A 9 1760 40 0.60 58 48 A 10 440 3 0.10 33 — A 11 880 9 0.15 45 — A 12 1340 25 0.40 55 — 6 5 P1 [W] A 1,0 300 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 140-AW21 -12 1.3 G3G 140-AW21 -12 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • Input for set value Lin 0-10 VDC / PWM • Tach output • Locked-rotor protection (1.7 V 50 m3/h, 10 V 300 m3/h) – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for – Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586) EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips max. 227,8 6,6 Accessories 103 107 M4 Technology 247 Ø158 6 85 450 +20 max. 262,6 92 94 Ø118-1 100±1 16 455 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 602 Contacts 120 105 130 115 EC centrifugal fan and blowers single inlet, constant air flow, Ø 140 subject to alterations rpm W A 50/60 1380 70 0.60 1~ 230 Electr. connection Hz Perm. amb. temp. A VAC Min. back pressure M3G 055-CF Max. current draw (1) *3G 140 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: PP plastic Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 602 -25 to +60 H2) 0 (1) Nominal data in operating point with maximum load and 230 VAC [Pa] Curves A 1,5 400 300 1 2 200 0,5 100 10 0 50 100 456 9 8 7 12 11 100 150 200 200 300 250 400 [CFM] I [A] LpA [dB(A)] tL [%] 1 2380 33 0.25 59 37 A 2 2495 51 0.45 60 50 A 3 2400 67 0.55 60 57 A 4 2030 22 0.20 54 38 A 5 2000 34 0.30 55 54 A 6 2110 61 0.50 60 55 A 7 1325 12 0.10 46 36 A 8 1460 21 0.20 51 48 A 9 1755 43 0.35 58 48 A 10 480 3 0.05 33 — A 11 890 11 0.10 45 — A 12 1380 31 0.25 55 — 6 5 4 P1 [W] A 1,0 3 n [rpm] General information Centrifugal fan kg Centrifugal blower with flange kg R3G 140-AW05 -12 1.3 G3G 140-AW05 -12 2.6 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • Input for set value Lin 0-10 VDC / PWM • Tach output • Locked-rotor protection (1.7 V 50 m3/h, 10 V 300 m3/h) – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, CE – Approvals: GOST; VDE, UL, CSA, CCC are applied for – Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586) EC-SYSTEMS EC centrifugal, forward Depth of screw max. 6 mm Brass lead tips max. 227,8 6,6 Accessories 103 107 M4 Technology 247 Ø158 6 85 450 +20 max. 262,6 92 94 Ø118-1 100±1 16 457 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 602 Contacts 120 105 130 115 EC centrifugal fan and blowers single inlet, Ø 146 subject to alterations rpm W A 50/60 2430 170 2.20 1~ 100-130 A Electr. connection Hz Perm. amb. temp. VAC Min. back pressure M3G 074-CF Max. current draw (1) *3G 146 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 115 VAC A 2 [Pa] [in H O] Curves 600 2,0 500 4 3 8 400 1,5 7 300 12 1,0 2 0,5 6 16 15 100 10 14 13 0 100 100 458 9 200 200 300 400 5 300 500 1 [CFM] 600 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2430 168 2.10 71 — A 2 2720 167 2.10 70 40 A 3 3040 159 2.00 68 55 A 4 3230 119 1.50 67 50 A 5 2120 110 1.40 67 — A 6 2390 109 1.40 66 40 A 7 2700 109 1.40 65 56 A 8 2800 77 1.00 63 49 A 9 1770 66 0.90 63 — A 10 1980 66 0.90 62 39 A 11 2230 65 0.90 60 53 A 12 2330 48 0.70 59 44 A 13 1250 26 0.40 54 — A 14 1390 26 0.40 52 32 A 15 1520 24 0.40 51 43 A 16 1560 19 0.30 50 32 11 200 n [rpm] General information Centrifugal blower with flange kg R3G 146-AB72 -01 2.0 G3G 146-AB72 -01 3.5 AC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm M4 117±1,5 114±1,5 84,5±1 EC centrifugal, forward M4 M4 45˚ 0 +2 EC-SYSTEMS max. 62,5 Ø5 Ø9 8 Ø1 0 25 min. Ø119,5 max. Ø146,5 4x90˚ Ø92 Ø133±0,3 max. Ø115,3 EC centrifugal, backward for clean rooms kg EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan Centrifugal fan 45 AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for 0 8 85 94 max. 262,6 58 Ø125,5 -1 Ø1 108 M4 45 85 0 +2 100±1 0 Technology Accessories 103 92 120 105 max. 227,8 Ø6,3 130 115 Core-end sleeves 8 459 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 603 Contacts 132,5±1,5 EC centrifugal fan and blowers single inlet, Ø 146 subject to alterations rpm W A 50/60 2520 175 1.30 1~ 200-277 A Electr. connection Hz Perm. amb. temp. VAC Min. back pressure M3G 074-CF Max. current draw (1) *3G 146 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 230 VAC A 2 [Pa] [in H O] Curves 600 n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2520 175 1.30 71 — A 2 2840 172 1.20 70 43 A 3 3030 144 1.10 68 60 A 4 3210 105 0.80 67 51 A 5 2430 172 1.30 71 — A 6 2545 138 1.10 68 42 A 7 2655 105 0.80 65 60 A 8 2770 78 0.60 63 50 A 9 2080 108 0.80 67 — A 10 2160 84 0.70 64 41 A 11 2240 70 0.60 66 52 A 12 2310 50 0.40 59 51 A 13 1540 48 0.40 59 — A 14 1580 39 0.30 56 34 A 15 1610 29 0.25 52 41 A 16 1640 22 0.20 51 40 500 2,0 4 3 8 1,5 400 7 300 12 1,0 11 2 200 6 16 0,5 15 10 100 14 13 0 100 100 460 9 300 200 200 300 400 500 5 1 [CFM] 600 [m3/h] General information Centrifugal blower with flange kg R3G 146-AB54 -01 2.0 G3G 146-AB54 -01 3.5 AC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm M4 117±1,5 114±1,5 84,5±1 EC centrifugal, forward M4 M4 45˚ 0 +2 EC-SYSTEMS max. 62,5 Ø5 Ø9 8 Ø1 0 25 min. Ø119,5 max. Ø146,5 4x90˚ Ø92 Ø133±0,3 max. Ø115,3 EC centrifugal, backward for clean rooms kg EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan Centrifugal fan 45 AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for 0 8 85 94 max. 262,6 58 Ø125,5 -1 Ø1 108 M4 45 85 0 +2 100±1 0 Technology Accessories 103 92 120 105 max. 227,8 Ø6,3 130 115 Core-end sleeves 8 461 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 603 Contacts 132,5±1,5 EC centrifugal fan and blowers single inlet, Ø 160 W A 50/60 2100 170 2.20 Electr. connection rpm Perm. amb. temp. Hz 1~ 100-130 A subject to alterations VAC Min. back pressure M3G 074-CF Max. current draw (1) *3G 160 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 115 VAC A 2 [Pa] [in H O] Curves 600 2,0 4 500 400 1,5 300 1,0 7 12 200 0,5 11 2 100 16 6 15 10 14 13 0 100 100 462 9 200 200 300 400 5 300 500 1 [CFM] 600 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2100 166 2.10 69 — A 2 2230 167 2.10 68 41 A 3 2550 164 2.10 69 58 A 4 2640 104 1.40 67 49 A 5 1810 106 1.40 64 — A 6 1930 105 1.40 64 38 A 7 2160 102 1.30 65 55 A 8 2230 62 0.90 62 43 A 9 1510 64 0.90 60 — A 10 1600 64 0.90 60 36 A 11 1780 61 0.90 60 49 A 12 1830 41 0.60 58 39 A 13 1020 25 0.40 51 — A 14 1080 24 0.40 50 29 A 15 1150 22 0.30 50 37 A 16 1170 16 0.30 47 25 3 8 n [rpm] General information Centrifugal blower with flange kg R3G 160-AC70 -01 2.0 G3G 160-AC70 -01 3.5 EC centrifugal, forward M4 M4 45˚ EC-SYSTEMS max. 61,7 Ø5 Ø9 8 Ø1 0 25 min. Ø136 max. Ø160,5 4x90˚ Ø92 Ø133±0,3 max. Ø115,3 AC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm M4 114±1,5 111±1,5 81,5±1 45 EC centrifugal, backward for clean rooms kg EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan Centrifugal fan 0 +2 AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for 0 8 85 94 max. 262,6 75 Ø130-1 Ø1 108 M4 45 85 0 +2 100±1 0 Technology Accessories 103 92 120 105 max. 227,8 Ø6,3 130 115 Core-end sleeves 8 463 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 603 Contacts 132,5±1,5 EC centrifugal fan and blowers single inlet, Ø 160 W A 50/60 2150 175 1.30 Electr. connection rpm Perm. amb. temp. Hz 1~ 200-277 A subject to alterations VAC Min. back pressure M3G 074-CF Max. current draw (1) *3G 160 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 230 VAC A 2 [Pa] [in H O] Curves 500 2,0 600 4 400 1,5 8 3 300 1,0 7 0,5 11 2 16 100 6 15 10 14 0 100 464 13 200 100 200 300 9 300 400 500 5 1 [CFM] 600 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 2150 170 1.25 70 — A 2 2320 172 1.30 70 39 A 3 2450 139 1.10 68 41 A 4 2540 91 0.70 67 46 A 5 2070 153 1.10 69 — A 6 2090 138 1.00 67 40 A 7 2150 101 0.80 65 56 A 8 2205 68 0.60 63 45 A 9 1700 91 0.70 63 — A 10 1730 80 0.60 62 37 A 11 1760 60 0.50 59 49 A 12 1795 41 0.30 58 37 A 13 1190 37 0.30 54 — A 14 1200 33 0.30 53 29 A 15 1220 27 0.25 51 35 A 16 1240 20 0.20 48 27 12 200 n [rpm] General information Centrifugal blower with flange kg R3G 160-AC50 -01 2.0 G3G 160-AC50 -01 3.5 EC centrifugal, forward M4 M4 45˚ EC-SYSTEMS max. 61,7 Ø5 Ø9 8 Ø1 0 25 min. Ø136 max. Ø160,5 4x90˚ Ø92 Ø133±0,3 max. Ø115,3 AC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm M4 114±1,5 111±1,5 81,5±1 45 EC centrifugal, backward for clean rooms kg EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan Centrifugal fan 0 +2 AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for 0 8 85 94 max. 262,6 75 Ø130-1 Ø1 108 M4 45 85 0 +2 100±1 0 Technology Accessories 103 92 120 105 max. 227,8 Ø6,3 130 115 Core-end sleeves 8 465 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 603 Contacts 132,5±1,5 EC centrifugal fan and blowers single inlet, constant air flow, Ø 160 subject to alterations rpm W A 50/60 1340 175 1.30 1~ 230 A Electr. connection Hz Perm. amb. temp. VAC Min. back pressure M3G 074-BF Max. current draw (1) *3G 160 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage Curve – Material: Housing: Die-cast aluminium Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 604 -25 to +60 J2) 0 (1) Nominal data in operating point with maximum load and 230 VAC [Pa] Curves A 3,0 800 600 2 3 400 4 1,0 200 8 7 11 10 0 50 100 466 100 150 200 9 12 200 300 250 400 [CFM] I [A] LpA [dB(A)] tL [%] 1 2910 110 0.90 68 44 A 2 2930 142 1.10 69 52 A 3 2780 175 1.30 71 63 A 4 2380 68 0.60 63 47 A 5 2360 88 0.70 65 58 A 6 2450 132 0.95 67 62 A 7 1690 35 0.30 57 49 A 8 1760 51 0.40 60 56 A 9 2020 94 0.70 63 50 A 10 610 9 0.10 40 — A 11 950 22 0.25 51 — A 12 1340 51 0.40 58 — 6 5 P1 [W] A 2,0 1 n [rpm] kg R3G 160-AD52 -01 2.0 G3G 160-AD52 -01 3.5 Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm M4 EC centrifugal, forward Ø5 Ø9 8 Ø1 0 25 max. 61,7 45˚ EC-SYSTEMS 45 M4 M4 min. Ø136 max. Ø160,5 4x90˚ Ø92 Ø133±0,3 max. Ø115,3 114±1,5 111±1,5 81,5±1 AC centrifugal, backward General information Centrifugal blower with flange EC centrifugal, backward for clean rooms kg EC centrifugal, backward Mass of centrifugal blower Mass of centrifugal fan Centrifugal fan 0 +2 • Over-temperature protected electronics / motor AC centrifugal, forward – Technical features: • PFC (passive) • Input for set value Lin 0-10 VDC / PWM • Output 10 VDC max. 1.1 mA • Tach output (1.7 V 50 m3/h, 10 V 300 m3/h) – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for – Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586) 0 8 85 94 max. 262,6 75 Ø130-1 Ø1 108 M4 45 85 0 +2 100±1 0 Technology Accessories 103 92 120 105 max. 227,8 Ø6,3 130 115 Core-end sleeves 8 467 Inlet nozzle p. 552 Guard grille p. 554 Air filter p. 563 Electr. connection p. 604 Contacts 132,5±1,5 EC centrifugal fan and blowers single inlet, Ø 180 W A 50/60 1320 175 2.20 Electr. connection rpm Perm. amb. temp. Hz 1~ 100-130 A subject to alterations VAC Min. back pressure M3G 074-CF Max. current draw (1) *3G 180 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 115 VAC 2 300 1,00 4 200 0,75 3 0,50 8 0,25 12 2 11 6 16 15 10 14 9 13 0 100 200 468 300 200 400 5 400 600 1 500 800 600 1000 [CFM] [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] 1 1320 171 2.10 67 — A 2 1370 151 1.90 65 57 A 3 1460 115 1.50 61 69 A 4 1570 69 0.90 59 59 A 5 990 69 0.90 59 — A 6 1030 65 0.90 57 54 A 7 1080 48 0.70 54 64 A 8 1130 29 0.40 51 57 A 9 770 35 0.50 52 — A 10 790 30 0.40 50 49 A 11 810 23 0.30 46 55 A 12 840 15 0.20 42 40 A 13 560 16 0.20 44 — A 14 560 13 0.20 40 38 A 15 580 11 0.20 36 41 A 16 590 8 0.10 33 24 7 100 n [rpm] A A 1,25 [Pa] [in H O] Curves General information Centrifugal fan kg Centrifugal blower without flange kg R3G 180-AU73 -01 2.0 G3G 180-EU73 -01 4.0 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm 179,5 129 285 136 Ø149-1 2 Ø19 0 8 469 Inlet nozzle p. 552 Guard grille p. 554 Electr. connection p. 603 Contacts 45 85 0 +2 Technology 332 6 Ø3,2 5° ° 0 x6 Accessories 123 134 Core-end sleeves EC centrifugal fan and blowers single inlet, Ø 180 subject to alterations Min. back pressure Perm. amb. temp. Electr. connection M3G 074-CF Max. current draw (1) *3G 180 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A Pa °C p. 603 50/60 1320 162 1.20 150 -25 to +60 J1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC n [rpm] A 2 [Pa] [in H O] Curves 200 4 0,75 250 1,0 300 3 150 8 100 7 0,25 6 12 11 50 10 16 15 14 13 0 200 470 5 9 200 400 400 600 800 600 [CFM] 1000 [m3/h] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1420 118 1.90 62 59 A 3 1445 106 1.50 61 69 A 4 1530 65 1.00 59 56 A 5 975 65 1.00 58 — A 6 995 56 0.90 56 54 A 7 1025 42 0.70 53 60 A 8 1065 26 0.45 49 45 A 9 745 31 0.50 52 — A 10 755 28 0.45 49 47 A 11 775 21 0.35 45 49 A 12 805 15 0.25 42 34 A 13 515 33 0.25 41 — A 14 520 12 0.20 39 33 A 15 535 10 0.20 35 34 A 16 560 8 0.15 32 20 0,5 2 P1 [W] General information Centrifugal fan kg Centrifugal blower without flange kg R3G 180-AU60 -01 2.0 G3G 180-EU60 -01 4.0 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw) Depth of screw 8-10 mm 179,5 129 285 136 Ø149-1 2 Ø19 0 8 471 Inlet nozzle p. 552 Guard grille p. 554 Electr. connection p. 603 Contacts 45 85 0 +2 Technology 332 6 Ø3,2 5° ° 0 x6 Accessories 123 134 Core-end sleeves EC centrifugal fan and blowers single inlet, Ø 180 Perm. amb. temp. Electr. connection VAC Hz rpm W A Pa °C p. 605 50/60 1970 335 3.90 200 -25 to +60 K1) 1~ 100-130 A subject to alterations Min. back pressure M3G 084-DF Max. current draw (1) *3G 180 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 115 VAC n [rpm] 2 [Pa] 2,5 [in H O] Curves 4 2,0 500 3 1,5 400 300 8 1,0 7 12 2 11 200 0,5 6 10 100 0 472 400 200 200 400 600 600 800 1000 800 1200 1400 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1970 335 3.90 76 52 A 3 2100 265 3.15 72 62 A 4 2205 195 2.35 70 56 A 5 — — — — — A 6 1700 213 2.45 71 52 A 7 1700 140 1.65 65 62 A 8 1700 90 1.10 63 56 A 600 P1 [W] A 9 — — — — — A 10 1500 147 1.70 68 52 A 11 1500 96 1.15 62 62 A 12 1500 61 0.75 59 46 General information Centrifugal fan kg Centrifugal blower without flange kg R3G 180-AA01 -81 3.9 G3G 180-AA01 -81 6.0 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 285 195 5° ° 0 x6 Accessories 123 134 129 Ø3,2 Core-end sleeves Technology Ø149 -1 332 6 2 136 0 +2 0 60 Ø19 85 Guard grille p. 554 Electr. connection p. 605 Contacts 8 473 Inlet nozzle p. 552 EC centrifugal fan and blowers single inlet, Ø 180 Perm. amb. temp. Electr. connection VAC Hz rpm W A Pa °C p. 605 50/60 2450 510 3.15 300 -25 to +60 K1) 1~ 200-277 A subject to alterations Min. back pressure M3G 084-FA Max. current draw (1) *3G 180 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 230 VAC n [rpm] 2 A 3 2,0 600 2,5 4 8 1,5 400 7 1,0 2 200 12 6 0,5 11 10 9 250 0 200 474 400 5 750 500 600 800 1000 1200 [CFM] 1400 [m3/h] I [A] LpA [dB(A)] tL [%] 1 — — — — — A 2 2450 510 3.15 79 47 A 3 2570 361 2.25 75 58 A 4 2690 223 1.45 73 45 A 5 2000 395 2.50 77 — A 6 2000 295 1.90 73 47 A 7 2000 185 1.20 68 58 A 8 2000 100 0.60 64 45 A 9 1400 135 0.90 67 — A 10 1400 100 0.60 64 47 A 11 1400 65 0.40 59 58 A 12 1400 35 0.20 55 45 3,0 800 P1 [W] A 3,5 [Pa] [in H O] Curves General information Centrifugal fan kg Centrifugal blower without flange kg R3G 180-AD43 -71 4.7 G3G 180-AD43 -71 6.8 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 285 195 5° ° 0 x6 Accessories 123 134 129 Ø3,2 Core-end sleeves Technology Ø149 -1 332 6 2 136 0 +2 0 60 Ø19 85 Guard grille p. 554 Electr. connection p. 605 Contacts 8 475 Inlet nozzle p. 552 EC centrifugal fan and blowers single inlet, Ø 200 subject to alterations Perm. amb. temp. Electr. connection A Min. back pressure M3G 084-FA Max. current draw (1) *3G 200 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A Pa °C p. 605 50/60 1720 350 4.20 150 -25 to +60 K1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC n [rpm] 2 2,4 [Pa] 500 A 2,0 600 [in H O] Curves 400 1,6 4 1,2 200 0,8 3 300 100 0,4 2 250 0 200 476 400 500 600 800 750 1000 1200 [CFM] 1400 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1720 350 4.10 73 49 A 3 1780 277 3.40 71 58 A 4 1945 152 2.10 69 50 General information Centrifugal fan kg Centrifugal blower without flange kg R3G 200-AL36 -81 5.2 G3G 200-AL36 -81 7.4 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 318 5° ° 60 371 3 Ø21 +2 0 60 0 152 85 8 477 Inlet nozzle p. 552 Electr. connection p. 605 Contacts Ø175 -1 6x Accessories 146 136 Technology 208 142,5 Ø3,2 Core-end sleeves EC centrifugal fan and blowers single inlet, Ø 200 subject to alterations Perm. amb. temp. Electr. connection A Min. back pressure M3G 084-FA Max. current draw (1) *3G 200 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A Pa °C p. 605 50/60 1890 510 3.10 150 -25 to +60 K1) 1~ 200-277 (1) Nominal data in operating point with maximum load and 230 VAC n [rpm] 300 2 2,4 8 3 7 0,8 12 200 11 6 2 16 0,4 100 15 10 14 9 13 250 0 200 478 I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1890 490 3.00 76 46 A 3 1960 403 2.40 74 57 A 4 2050 322 2.00 73 58 A 5 1800 510 3.10 77 — A 6 1800 420 2.50 75 46 A 7 1800 320 1.90 71 57 A 8 1800 220 1.30 69 58 A 9 1400 240 1.50 71 — A 10 1400 200 1.20 68 46 A 11 1400 145 0.90 65 57 A 12 1400 103 0.70 63 58 A 13 1000 87 0.60 63 — A 14 1000 72 0.50 60 46 A 15 1000 55 0.40 57 57 A 16 1000 38 0.30 53 58 4 2,0 [Pa] 400 P1 [W] 1,6 500 A 1,2 600 [in H O] Curves 400 500 600 800 750 1000 1200 5 [CFM] 1400 [m3/h] General information Centrifugal fan kg Centrifugal blower without flange kg R3G 200-AL29 -71 5.2 G3G 200-AL29 -71 7.4 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 318 5° ° 60 371 3 Ø21 +2 0 60 0 152 85 8 479 Inlet nozzle p. 552 Electr. connection p. 605 Contacts Ø175 -1 6x Accessories 146 136 Technology 208 142,5 Ø3,2 Core-end sleeves EC centrifugal fan and blowers single inlet, Ø 225 subject to alterations Perm. amb. temp. Electr. connection A Min. back pressure M3G 084-FA Max. current draw (1) *3G 225 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A Pa °C p. 605 50/60 1500 350 4.30 150 -25 to +60 K1) 1~ 100-130 (1) Nominal data in operating point with maximum load and 115 VAC n [rpm] 2 2,4 [Pa] 500 A 2,0 600 [in H O] Curves 1,6 4 400 1,2 200 0,8 3 300 0,4 2 100 250 0 200 480 400 500 600 800 750 1000 1200 [CFM] 1400 [m3/h] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1500 350 4.30 72 48 A 3 1620 300 3.60 69 60 A 4 1775 205 2.70 68 56 General information Centrifugal fan kg Centrifugal blower without flange kg R3G 225-AL36 -81 5.3 G3G 225-AL36 -81 7.5 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 318 146 5° ° 0 x6 Accessories 148 136 208 142,5 Ø3,2 Core-end sleeves 152 0 +2 Technology 371 2 Ø24 0 60 85 8 481 Inlet nozzle p. 552 Electr. connection p. 605 Contacts Ø194 -1 6 EC centrifugal fan and blowers single inlet, Ø 225 Perm. amb. temp. Electr. connection VAC Hz rpm W A Pa °C p. 605 50/60 1815 545 3.50 300 -25 to +60 K1) 1~ 200-277 A subject to alterations Min. back pressure M3G 084-FA Max. current draw (1) *3G 225 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 230 VAC n [rpm] 2 2,4 [Pa] 400 4 2,0 500 A 3 1,6 600 [in H O] Curves 1,2 2 12 0,8 11 10 16 0,4 0 14 250 400 482 tL [%] 1 — — — — — A 2 1815 545 3.50 75 53 A 3 1900 456 2.90 74 60 A 4 1995 363 2.35 73 59 A 5 1610 592 3.85 76 — A 6 1610 381 2.45 71 53 A 7 1610 278 1.80 69 60 A 8 1610 191 1.25 66 59 A 9 1300 312 2.05 72 — A 10 1300 200 1.30 66 53 A 11 1300 146 0.95 63 60 A 12 1300 101 0.65 61 59 A 13 1000 142 0.95 65 — A 14 1000 91 0.60 59 53 A 15 1000 67 0.45 56 60 A 16 1000 46 0.30 54 59 15 100 LpA [dB(A)] A 6 200 I [A] 8 7 300 P1 [W] 500 800 13 750 1200 9 1000 1600 5 [CFM] [m3/h] General information Centrifugal fan kg Centrifugal blower without flange kg R3G 225-AD29 -71 5.3 G3G 225-AD29 -71 7.5 EC centrifugal, backward EC centrifugal, backward for clean rooms Mass of centrifugal fan Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, CCC, GOST are applied for EC-SYSTEMS EC centrifugal, forward Depth of screw 8-10 mm 318 146 5° ° 0 x6 Accessories 148 136 208 142,5 Ø3,2 Core-end sleeves 152 0 +2 Technology 371 2 Ø24 0 60 85 8 483 Inlet nozzle p. 552 Electr. connection p. 605 Contacts Ø194 -1 6 EC centrifugal fan single inlet, Ø 250 subject to alterations Min. back pressure Perm. amb. temp. Electr. connection M3G 084-FA Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 – Insulation class: "B" – Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm W A Pa °C p. 605 50/60 1230 450 2.90 180 -25 to +45 K1) 1~ 200-277 A (1) Nominal data in operating point with maximum load and 230 VAC n [rpm] A 2 [Pa] [in H O] Curves 400 1,4 350 4 1,2 300 200 0,8 250 1,0 7 2 12 100 0,6 10 15 0,2 16 50 6 0,4 150 11 14 0 250 400 484 500 800 750 1200 1000 1600 1250 2000 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1230 450 2.90 72 50 A 3 1370 338 2.20 70 60 A 4 1460 266 1.70 68 56 A 5 — — — — — A 6 1160 357 2.30 71 50 A 7 1270 269 1.70 67 60 A 8 1320 195 1.30 66 56 A 9 — — — — — A 10 900 166 1.10 64 50 A 11 960 118 0.80 60 60 A 12 990 87 0.60 58 56 A 13 — — — — — A 14 600 54 0.40 53 50 A 15 630 37 0.30 48 60 A 16 640 31 0.20 46 56 3 8 P1 [W] General information Centrifugal fan kg Inlet nozzle Flange R3G 250-AQ28 -71 5.6 25010-2-4013 10011-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Alarm relay • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 61800-5-1, CE – Approvals: UL, CSA, GOST; CCC is applied for Depth of screw 8-10 mm Core-end sleeves Scroll housing used: 138 18 147 30˚ 30˚ 30˚ 158 485 Inlet nozzle p. 552 Electr. connection p. 605 Contacts 170 184 ˚ 30 30 ˚ 30˚ 213 Technology 30 ˚ 65 ˚ 25˚ 230 30˚ 30˚ 247 203 267 287 150 198 View Z Accessories Housing width EC centrifugal fan single inlet, Ø 250 subject to alterations rpm kW A 50/60 1320 0.76 3.30 1~ 200-277 Electr. connection Hz Perm. amb. temp. A VAC Min. back pressure M3G 112-EA Max. current draw (1) R3G 250 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 607 -25 to +60 L1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 4 1,4 [Pa] 300 A 1,2 350 [in H O] Curves 250 1,0 200 0,8 8 3 7 0,6 2 150 12 6 100 0,4 11 10 50 0,2 16 15 14 9 13 0 250 400 486 500 800 750 1200 1000 1600 5 1250 2000 1 [CFM] 2400 [m3/h] n [rpm] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1320 0.76 3.30 81 — A 2 1380 0.61 2.70 78 46 A 3 1410 0.51 2.30 76 50 A 4 1450 0.39 1.70 73 53 A 5 1190 0.55 2.40 78 — A 6 1220 0.43 1.90 75 46 A 7 1250 0.36 1.60 73 50 A 8 1280 0.28 1.20 69 53 A 9 910 0.25 1.10 71 — A 10 930 0.20 0.90 67 46 A 11 940 0.16 0.70 65 50 A 12 950 0.13 0.60 61 53 A 13 610 0.09 0.40 59 — A 14 610 0.07 0.40 55 46 A 15 620 0.06 0.30 53 50 A 16 630 0.05 0.30 49 53 General information AC centrifugal, backward Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • Centrifugal fan kg Inlet nozzle Flange R3G 250-AS51 -11 7.6 25010-2-4013 10025-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 610800-5-1) – Product conforming to standard: CE – Approvals: UL, CSA, GOST, CCC are applied for Housing width Depth of screw 12-16 mm Scroll housing used: 138 18 147 30˚ 30˚ 30˚ 158 487 Inlet nozzle p. 552 Electr. connection p. 607 Contacts 170 184 ˚ 30 30 ˚ 30˚ 213 Technology 30 ˚ 65 ˚ 25˚ 230 30˚ 30˚ 247 203 267 287 150 198 View Z Accessories Cable gland EC centrifugal fan single inlet, Ø 280 kW A 50/60 1130 0.75 3.30 Electr. connection rpm Perm. amb. temp. Hz 1~ 200-277 A subject to alterations VAC Min. back pressure M3G 112-GA Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 607 -25 to +50 L1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 [Pa] A 2,0 500 [in H O] Curves 400 1,6 4 300 1,2 8 3 0,8 12 2 6 100 0,4 11 10 16 15 14 13 0 400 488 800 5 1 1500 [CFM] 9 1000 500 1200 1600 2000 2400 [m3/h] P1 [kW] I [A] LpA [dB(A)] tL [%] A 1 1130 0.75 3.30 78 — A 2 1170 0.60 2.70 75 53 A 3 1210 0.53 2.30 73 54 A 4 1250 0.32 1.40 69 51 A 5 1020 0.56 2.50 76 — A 6 1050 0.44 2.00 72 53 A 7 1070 0.37 1.60 70 54 A 8 1110 0.23 1.00 65 51 A 9 780 0.25 1.10 69 — A 10 790 0.20 0.90 65 53 A 11 800 0.17 0.80 63 54 A 12 820 0.11 0.50 58 51 A 13 520 0.09 0.40 58 — A 14 530 0.08 0.40 54 53 A 15 530 0.07 0.30 51 54 A 16 550 0.05 0.30 46 51 7 200 n [rpm] General information AC centrifugal, backward Line undervoltage detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, forward • • • • • Centrifugal fan kg Inlet nozzle Flange R3G 280-AN32 -11 9.4 28010-2-4013 10026-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward – Technical features: • Slave output 0-10 V max. 3 mA • PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Control input 0-10 VDC / PWM • RS485 ebmBUS • Input for sensor 0-10 V or 4-20 mA • Alarm relay – EMC: Interference emission acc. to EN 61000-6-4 (industrial environment) Interference immunity acc. to EN 61000-6-2 (industrial environment) Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 610800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST, CCC are applied for Housing width Depth of screw 12-16 mm Scroll housing used: 162 13 152 30˚ 30 30˚ 30˚ 148 489 Inlet nozzle p. 552 Electr. connection p. 607 Contacts 161 172 ˚ 30 ˚ 30˚ 200 Technology 30 ˚ 65 ˚ 25˚ 218 30˚ 30˚ 236 205 254 266 180 183 View Z Accessories Cable gland EC centrifugal fan single inlet, Ø 280 kW A 50/60 1300 1.10 2.00 Electr. connection rpm Perm. amb. temp. Hz 3~ 380-480 A subject to alterations VAC Min. back pressure M3G 112-GA Max. current draw (1) R3G 280 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 607 -25 to +50 L2) 0 (1) Nominal data in operating point with maximum load and 400 VAC A 2 [Pa] [in H O] Curves 700 2,8 800 400 3 1,2 12 200 0,8 2 16 10 0,4 100 6 11 15 14 400 490 13 1000 500 0 800 1200 1600 5 9 1 1500 2000 2400 [CFM] 2800 3200 [m3/h] I [A] LpA [dB(A)] tL [%] 1 1300 1.10 2.00 82 — A 2 1370 0.94 1.80 79 55 A 3 1420 0.81 1.50 77 59 A 4 1540 0.53 1.00 73 57 A 5 1200 0.87 1.60 79 — A 6 1260 0.73 1.40 76 55 A 7 1310 0.62 1.20 75 59 A 8 1400 0.40 0.80 71 57 A 9 970 0.46 0.90 74 — A 10 990 0.36 0.80 70 55 A 11 1010 0.30 0.60 68 59 A 12 1050 0.19 0.50 63 57 A 13 660 0.16 0.40 64 — A 14 680 0.13 0.30 60 55 A 15 680 0.11 0.30 58 59 A 16 710 0.08 0.20 53 57 7 300 P1 [kW] A 8 2,0 500 1,6 600 2,4 4 n [rpm] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay Centrifugal fan kg Inlet nozzle Flange R3G 280-AN32 -01 9.4 28010-2-4013 10026-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 610800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST, CCC are applied for Housing width Depth of screw 12-16 mm Scroll housing used: 162 13 152 30˚ 30 30˚ 30˚ 148 491 Inlet nozzle p. 552 Electr. connection p. 607 Contacts 161 172 ˚ 30 ˚ 30˚ 200 Technology 30 ˚ 65 ˚ 25˚ 218 30˚ 30˚ 236 205 254 266 180 183 View Z Accessories Cable gland EC centrifugal fan single inlet, Ø 310 subject to alterations Perm. amb. temp. Electr. connection A Min. back pressure M3G 150-FF Max. current draw (1) R3G 310 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A Pa °C p. 608 50/60 1500 2.97 4.60 200 -25 to +45 M) 3~ 380-480 (1) Nominal data in operating point with maximum load and 400 VAC n [rpm] A 2 [Pa] [in H O] Curves 4 800 2,4 300 200 3 7 11 6 100 0,4 15 10 14 0 500 1000 492 1000 2000 1500 2000 3000 2500 4000 3000 5000 [CFM] [m3/h] tL [%] 1 — — — — — 2 1500 2.97 4.60 88 47 A 3 1600 2.34 3.70 85 57 A 4 1730 1.37 2.10 82 56 A 5 — — — — — A 6 1350 2.19 3.30 85 47 A 7 1440 1.71 2.60 82 57 A 8 1540 0.96 1.60 79 56 A 9 — — — — — A 10 1080 1.12 1.80 80 47 A 11 1120 0.82 1.40 76 57 A 12 1170 0.47 1.00 72 56 A 13 — — — — — A 14 730 0.37 0.90 69 47 A 15 750 0.27 0.70 65 57 A 16 780 0.16 0.50 60 56 2 16 LpA [dB(A)] A 12 0,8 400 1,6 500 1,2 600 2,0 2,8 8 700 I [A] A 3,2 900 P1 [kW] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg R3G 310-AU07 -03 19.4 Inlet nozzle Flange 31010-2-4013 10050-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan Centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST Depth of screw 20-25 mm Scroll housing used: 176 18 186 30˚ 30 30˚ 30˚ 200 493 Inlet nozzle p. 552 Electr. connection p. 608 Contacts 214 229 ˚ 30 ˚ 30˚ 264 Technology 65 ˚ 25˚ 283 30˚ 30 ˚ 303 249 325 349 184 30˚ View Z Accessories Housing width 246 Cable gland EC centrifugal fan single inlet, Ø 355 Perm. amb. temp. Electr. connection VAC Hz rpm kW A Pa °C p. 608 50/60 1180 2.60 4.00 300 -25 to +35 M) 3~ 380-480 A subject to alterations Min. back pressure M3G 150-FF Max. current draw (1) R3G 355 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 400 VAC n [rpm] A 2 [Pa] [in H O] Curves 700 3 400 2,4 7 2,0 500 8 1,6 600 I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1180 2.60 4.00 84 54 A 3 1280 1.95 3.00 80 64 A 4 1350 1.52 2.30 79 64 A 5 — — — — — A 6 1050 1.91 2.90 82 54 A 7 1130 1.36 2.00 77 64 A 8 1190 1.02 1.60 75 64 A 9 — — — — — A 10 840 0.97 1.70 76 54 A 11 890 0.66 1.30 71 64 A 12 920 0.49 1.00 68 64 A 13 — — — — — A 14 580 0.31 0.70 65 54 A 15 600 0.22 0.60 59 64 A 16 610 0.17 0.50 56 64 4 2,8 800 3,2 900 P1 [kW] 300 1,2 12 11 2 200 0,8 6 16 0,4 100 10 15 14 0 500 1000 494 1000 2000 1500 2000 3000 2500 4000 3000 5000 3500 [CFM] 6000 [m3/h] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg R3G 355-AR08 -03 19.9 Inlet nozzle Flange 35510-2-4013 10051-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan Centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST Depth of screw 20-25 mm Scroll housing used: 196 18 207 30˚ 30 30˚ 30˚ 222 495 Inlet nozzle p. 552 Electr. connection p. 608 Contacts 238 256 ˚ 30 ˚ 30˚ 294 Technology 65 ˚ 25˚ 315 30˚ 30 ˚ 338 280 362 389 203 30˚ View Z Accessories Housing width 274 Cable gland EC centrifugal fan single inlet, Ø 400 subject to alterations Min. back pressure Perm. amb. temp. Electr. connection M3G 150-IF Max. current draw (1) R3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings VAC Hz rpm kW A Pa °C p. 608 50/60 930 2.13 3.30 200 -25 to +45 M) 3~ 380-480 A (1) Nominal data in operating point with maximum load and 400 VAC n [rpm] 2 2,4 [Pa] 400 4 2,0 500 A 1,6 600 [in H O] Curves 1,2 7 0,8 11 2 16 6 15 10 0,4 100 14 0 500 1000 496 LpA [dB(A)] tL [%] 1 — — — — — A 2 930 2.13 3.30 83 54 A 3 980 1.68 2.60 80 63 A 4 1040 0.93 1.60 74 61 A 5 — — — — — A 6 830 1.49 2.40 80 54 A 7 830 1.01 1.60 75 63 A 8 830 0.46 0.80 67 61 A 9 — — — — — A 10 700 0.91 1.40 76 54 A 11 700 0.62 1.00 71 63 A 12 700 0.28 0.50 63 61 A 13 — — — — — A 14 550 0.44 0.70 69 54 A 15 550 0.30 0.50 65 63 A 16 550 0.14 0.20 56 61 3 12 200 I [A] A 8 300 P1 [kW] 1000 2000 1500 2000 3000 2500 4000 3000 5000 3500 6000 4000 7000 [CFM] [m3/h] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg R3G 400-AR04 -03 25.5 Inlet nozzle Flange 40010-2-4013 10052-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan Centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST Depth of screw 20-25 mm Scroll housing used: 220 20 233 30˚ 30 30˚ 30˚ 250 497 Inlet nozzle p. 552 Electr. connection p. 608 Contacts 268 288 ˚ 30 ˚ 30˚ 331 Technology 65 ˚ 25˚ 355 30˚ 30 ˚ 380 316 408 437 228 30˚ View Z Accessories Housing width 308 Cable gland EC centrifugal fan single inlet, Ø 400 Perm. amb. temp. Electr. connection VAC Hz rpm kW A Pa °C p. 608 50/60 1120 3.080 4.60 300 -25 to +55 M) 3~ 380-480 A subject to alterations Min. back pressure M3G 150-NA Max. current draw (1) R3G 400 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 400 VAC n [rpm] A 2 [Pa] [in H O] Curves 800 600 2,8 2,4 700 4 8 2,0 7 1,6 400 300 1,2 12 2 11 0,8 200 16 10 15 0,4 100 6 14 1000 0 1000 498 2000 2000 3000 3000 4000 5000 4000 6000 7000 [CFM] 8000 [m3/h] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 1120 3.08 4.60 87 49 A 3 1160 2.60 3.90 85 57 A 4 1220 1.53 2.30 79 58 A 5 — — — — — A 6 1000 2.16 3.20 84 49 A 7 1020 1.81 2.70 82 57 A 8 1060 1.02 1.70 75 58 A 9 — — — — — A 10 780 1.05 1.70 78 49 A 11 790 0.87 1.50 75 57 A 12 820 0.51 1.10 68 58 A 13 — — — — — A 14 520 0.35 0.80 67 49 A 15 530 0.31 0.70 64 57 A 16 550 0.19 0.50 57 58 3 500 P1 [kW] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg R3G 400-AT01 -03 30.0 Inlet nozzle Flange 40010-2-4013 10052-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan Centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST Depth of screw 20-25 mm Scroll housing used: 220 20 233 30˚ 30 30˚ 30˚ 250 499 Inlet nozzle p. 552 Electr. connection p. 608 Contacts 268 288 ˚ 30 ˚ 30˚ 331 Technology 65 ˚ 25˚ 355 30˚ 30 ˚ 380 316 408 437 228 30˚ View Z Accessories Housing width 308 Cable gland EC centrifugal fan single inlet, Ø 450 Perm. amb. temp. Electr. connection VAC Hz rpm kW A Pa °C p. 608 50/60 890 2.65 4.50 300 -25 to +50 M) 3~ 380-480 A subject to alterations Min. back pressure M3G 150-NA Max. current draw (1) R3G 450 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Impeller: Galvanised sheet steel Rotor: Coated in black Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings (1) Nominal data in operating point with maximum load and 400 VAC n [rpm] A 2 [Pa] [in H O] Curves 500 4 2,4 600 2,0 700 2,8 800 8 1,6 400 3 300 1,2 7 2 11 0,8 200 10 0,4 100 16 15 14 0 1000 2000 500 2000 3000 4000 4000 6000 5000 8000 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] A 1 — — — — — A 2 890 2.65 4.50 82 60 A 3 920 2.26 3.50 80 66 A 4 970 1.80 2.80 76 70 A 5 — — — — — A 6 790 1.82 3.20 79 60 A 7 810 1.58 2.80 76 66 A 8 840 1.17 2.20 74 70 A 9 — — — — — A 10 610 0.83 1.60 71 60 A 11 620 0.73 1.50 68 66 A 12 630 0.54 1.10 66 70 A 13 — — — — — A 14 410 0.27 0.70 60 60 A 15 420 0.23 0.60 57 66 A 16 420 0.18 0.50 54 70 12 6 P1 [kW] General information Line undervoltage / phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start kg R3G 450-AR03 -03 31.5 Inlet nozzle Flange 45010-2-4013 10053-2-4017 View with flange EC-SYSTEMS EC centrifugal, forward View without flange EC centrifugal, backward for clean rooms Mass of centrifugal fan Centrifugal fan AC centrifugal, backward • • • • • AC centrifugal, forward Slave output 0-10 V max. 3 mA Output 20 VDC (±20 %) max. 50 mA Output 10 VDC (+10 %) max. 10 mA RS485 ebmBUS Alarm relay EC centrifugal, backward – Technical features: • • PFC (passive) • • Integrated PID controller • • Control input 0-10 VDC / PWM • • Input for sensor 0-10 V or 4-20 mA • – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Connection leads: Via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standard: CE – Approvals: VDE, UL, CSA, GOST Depth of screw 20-25 mm Scroll housing used: 247 22 262 30˚ 30 30˚ 30˚ 281 501 Inlet nozzle p. 552 Electr. connection p. 608 Contacts 301 323 ˚ 30 ˚ 30˚ 371 Technology 65 ˚ 25˚ 398 30˚ 30 ˚ 427 355 458 491 255 30˚ View Z Accessories Housing width 346 Cable gland EC centrifugal blowers dual inlet, Ø 133 Voltage range Air flow Speed/rpm Power input Current draw Sound pressure level Min. back pressure Perm. amb. temp. Electr. connection VDC VDC m3/h rpm W A dB(A) Pa °C p. 600 A 24 16-28 700 1780 105 5.60 62 50 -25 to +60 G) A 48 36-57 700 1780 105 2.80 62 50 -25 to +60 G) Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Nominal data Type Motor D1G 133 M1G 074-BF D1G 133 M1G 074-BF subject to alterations n [rpm] 2 [Pa] 500 A 2,0 600 [in H O] Curves 4' UN UR 300 1,0 4 3' 8 200 3 0,5 7 2' 2 100 6 0 100 200 502 200 5 400 300 400 600 1 [CFM] 800 [m3/h] LpA [dB(A)] tL [%] A 1’ — — — — A 2’ 2050 121 63 49 A 3’ 2490 106 62 41 A 4’ 2820 100 62 37 A 1 1780 105 62 — A 2 1900 97 61 49 A 3 2310 86 59 41 A 4 2630 80 60 37 A 5 1500 73 59 — A 6 1720 67 57 49 A 7 2020 58 56 41 A 8 2230 49 56 37 1,5 400 P1 [W] General information kg D1G 133-AB29 -52 3.3 D1G 133-AB39 -52 3.3 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA; A (48 VDC) with CCC 215 EC centrifugal, forward 170,5 14 5 79 6 EC-SYSTEMS 85 180 Ø112 65,5 71 87 Accessories 190 Technology Brass lead tips 503 Guard grille p. 555 Electr. connection p. 600 Contacts 300 +20 EC centrifugal blowers dual inlet, Ø 133 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) D1G 133 M1G 074-CF A 24 16-28 1020 1580 118 6.00 64 D1G 133 M1G 074-CF A 48 36-57 1020 1580 118 3.00 64 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 1,5 400 300 1,0 4 3' 8 200 3 0,5 7 2' 100 2 6 5 0 200 200 504 400 400 600 800 1 600 1000 1' [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 1700 145 65 — A 2’ 1930 133 62 38 A 3’ 2290 122 59 41 A 4’ 2700 99 61 32 A 1 1580 118 64 — A 2 1790 107 61 38 A 3 2100 95 57 41 A 4 2410 73 58 32 A 5 1400 78 60 — A 6 1580 70 56 38 A 7 1760 56 53 41 A 8 2000 44 53 32 UR 4' UN n [rpm] General information kg D1G 133-DC13 -52 3.4 D1G 133-DC17 -52 3.4 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA 232 EC centrifugal, forward max. 204 EC-SYSTEMS 67,5 93,5 85 max. 214 Ø112 104 96 14 5 6 Accessories 190 Technology Brass lead tips 505 Guard grille p. 555 Electr. connection p. 600 Contacts 300 +20 EC centrifugal blowers dual inlet, Ø 146 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) D1G 146 M1G 074-CF A 24 16-28 1000 1350 105 5.10 61 D1G 146 M1G 074-CF A 48 36-57 1000 1350 105 2.60 61 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations A 2 [Pa] [in H O] Curves 1,5 4' 1,0 300 4 UN 3' 200 3 0,5 8 7 2' 2 100 6 5 0 200 200 506 400 400 600 800 1' 1 600 1000 [CFM] [m3/h] P1 [W] LpA [dB(A)] tL [%] A 1’ 1460 129 63 — A 2’ 1680 119 60 53 A 3’ 1890 111 58 61 A 4’ 2240 95 59 55 A 1 1350 105 61 — A 2 1570 95 58 53 A 3 1750 88 56 61 A 4 2010 70 57 55 A 5 1210 70 56 — A 6 1360 60 54 53 A 7 1460 53 52 61 A 8 1670 42 51 55 400 UR n [rpm] General information kg D1G 146-AA19 -52 3.5 D1G 146-AA33 -52 3.5 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA 232 max. 104,5 EC-SYSTEMS 219 14 5 98 6 69 96 Ø117-0,5 85 EC centrifugal, forward max. 206 Accessories 180 Technology Brass lead tips 507 Guard grille p. 555 Electr. connection p. 600 Contacts 350 +20 EC centrifugal blowers dual inlet, Ø 160 Power input Current draw Sound pressure level Motor VDC m3/h rpm W A dB(A) D1G 160 M1G 074-CF A 24 16-28 980 1250 112 5.60 60 D1G 160 M1G 074-CF A 48 36-57 980 1250 112 2.90 60 Electr. connection Speed/rpm Type Perm. amb. temp. Air flow Nominal data Min. back pressure Voltage range VDC Curve Nominal voltage – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Coated in black – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 42 – Insulation class: "B" – Mounting position: Any – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Design: Standard external-rotor motor anti-vibration mounted on both sides – Bearings: Maintenance-free ball bearings Pa °C p. 600 0 -25 to +60 G) 0 -25 to +60 G) subject to alterations 2 [Pa] A 2,0 500 [in H O] Curves 1,5 400 4' UR UN 300 1,0 4 3' 8 200 3 0,5 7 2' 100 6 2 5 0 200 200 508 400 400 600 800 1 1' 600 [CFM] 1000 [m3/h] n [rpm] P1 [W] LpA [dB(A)] tL [%] A 1’ 1330 142 63 — A 2’ 1520 128 61 64 A 3’ 1790 115 59 66 A 4’ 2090 105 60 60 A 1 1250 112 60 — A 2 1420 102 59 64 A 3 1660 92 58 66 A 4 1900 80 58 60 A 5 1100 75 58 — A 6 1250 69 56 64 A 7 1420 58 54 66 A 8 1580 47 53 60 General information kg D1G 160-DA19 -52 3.6 D1G 160-DA33 -52 3.6 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Tach output • Control input 0-10 VDC / PWM • Reverse polarity and locked-rotor protection – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 – Cable exit: Variable – Protection class: I – Product conforming to standard: EN 60950-1 – Approvals: UL, CSA EC centrifugal, forward max. 226 102 5 17 max. 242 EC-SYSTEMS 6 100,5 85 Ø Brass lead tips Ø130 ±0,5 87 max. 107 max. 176,5 509 Guard grille p. 555 Electr. connection p. 600 Contacts Technology Accessories 400 +20 EC centrifugal blowers dual inlet, Ø 146 W A 50/60 1740 171 1.30 Electr. connection rpm Perm. amb. temp. Hz 1~ 200-277 A subject to alterations VAC Min. back pressure M3G 074-CF Max. current draw (1) D3G 146 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 [Pa] [in H O] Curves 1,5 1,0 3 8 200 7 0,5 2 12 6 100 11 10 0 100 200 510 9 400 300 200 400 600 5 500 800 600 1000 1 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1740 171 1.30 67 — A 2 1960 169 1.20 65 49 A 3 2150 165 1.20 65 56 A 4 2410 166 1.20 66 55 A 5 1460 103 0.70 62 — A 6 1650 102 0.80 60 46 A 7 1820 104 0.80 60 53 A 8 2020 102 0.70 61 52 A 9 1090 47 0.40 55 — A 10 1220 46 0.40 56 41 A 11 1330 46 0.40 52 47 A 12 1480 46 0.40 53 44 400 300 P1 [W] A A 4 n [rpm] General information kg D3G 146-AH50 -01 4.0 EC centrifugal, backward for clean rooms Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for max. 206 219 232 EC centrifugal, forward max. 104,5 50 27 96 Ø5 5 98 EC-SYSTEMS Ø117-0,5 350+20 511 Guard grille p. 555 Electr. connection p. 603 Contacts Technology Accessories Core-end sleeves EC centrifugal blowers dual inlet, Ø 160 subject to alterations rpm W A 50/60 1390 154 1.20 1~ 200-277 A Electr. connection Hz Perm. amb. temp. VAC Min. back pressure M3G 074-CF Max. current draw (1) D3G 160 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 0,75 200 3 160 120 7 80 2 0,25 12 11 6 40 10 9 0 100 200 512 300 200 400 400 600 500 800 5 600 1000 1 [CFM] [m3/h] I [A] LpA [dB(A)] tL [%] 1 1390 154 1.20 64 — 2 1440 129 1.00 61 53 A 3 1540 93 0.70 57 60 A 4 1590 63 0.50 56 47 A 5 1180 96 0.70 59 — A 6 1220 79 0.60 56 52 A 7 1270 54 0.40 52 57 A 8 1310 37 0.30 51 44 A 9 860 40 0.30 51 — A 10 890 34 0.30 47 45 A 11 910 24 0.20 43 45 A 12 930 18 0.20 42 31 0,5 8 P1 [W] A 240 4 n [rpm] A A 1,0 [Pa] [in H O] Curves General information EC centrifugal, backward for clean rooms EC centrifugal, forward EC-SYSTEMS 4.9 Core-end sleeves Accessories D3G 160-BF60 -01 Technology kg 513 Guard grille p. 555 Electr. connection p. 603 Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for EC centrifugal blowers dual inlet, Ø 180 W A 50/60 1090 165 1.22 Electr. connection rpm Perm. amb. temp. Hz 1~ 200-277 A subject to alterations VAC Min. back pressure M3G 074-CF Max. current draw (1) D3G 180 Max. power input (1) Motor Speed/rpm Type Frequency Nominal data Nominal voltage range Curve – Material: Housing: Galvanised sheet steel Impeller: Galvanised sheet steel Rotor: Galvanised Electronics enclosure: Die-cast aluminium – Direction of rotation: Clockwise, seen on rotor – Type of protection: IP 44 – Insulation class: "B" – Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request – Condensate discharges: None – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C p. 603 -25 to +60 J1) 0 (1) Nominal data in operating point with maximum load and 230 VAC 2 [Pa] 4 0,75 200 3 150 0,50 8 n [rpm] P1 [W] I [A] LpA [dB(A)] tL [%] A 1 1090 165 1.22 64 — A 2 1200 155 1.15 62 54 A 3 1310 113 0.85 59 62 A 4 1400 74 0.55 56 53 A 5 925 101 0.75 60 — A 6 1015 95 0.70 58 51 A 7 1090 67 0.50 54 61 A 8 1145 45 0.35 51 48 A 9 690 43 0.35 52 — A 10 760 42 0.30 50 47 A 11 805 31 0.25 46 51 A 12 840 21 0.20 43 39 A 13 455 15 0.15 40 — A 14 500 15 0.15 38 36 A 15 525 12 0.10 34 35 A 16 545 9 0.10 32 23 A 1,00 250 [in H O] Curves 7 100 12 0,25 2 11 50 6 16 10 15 14 13 0 250 400 514 9 500 800 1 [CFM] 5 750 1200 1600 [m3/h] General information 7.0 EC centrifugal, backward for clean rooms D3G 180-AB62 -01 309 255 180 296 7 133 EC centrifugal, forward kg 136 90 EC-SYSTEMS 1 600 Core-end sleeves Accessories 3,2 92 255 Technology 333 ˚ Ø 149 60 134 289 6x 188 168 5˚ 515 Guard grille p. 555 Electr. connection p. 603 Contacts Centrifugal blower without flange EC centrifugal, backward Mass of centrifugal blower AC centrifugal, forward AC centrifugal, backward – Technical features: • Output 10 VDC max. 1.1 mA • PFC (passive) • Tach output • Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 Harmonics acc. to DIN EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 60950-1 – Cable exit: Variable – Protection class: I – Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE – Approvals: UL, CSA; CCC, GOST are applied for 516 General information Switch power supplies 522 External commutation electronics for rail technology 526 Accessories: Temperature sensor / control module, pressure control, selection module, interface converter, ... 528 HMS controller 546 AC centrifugal, backward 518 517 Contacts Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Options AC centrifugal, forward EC-SYSTEMS EC-SYSTEMS Options EC fan PWM and Lin 0-10 VDC red Linear input: < 1 VDC 1 VDC 10 VDC 24 / 48 VDC blue Control input Lin yellow 0-10 VDC EC fans 24 / 48 VDC with integrated commutation electronics -> n=0 -> nmin -> nmax PWM PWM input: < 10% PWM -> n=0 10% PWM -> nmin 100% PWM -> nmax white Tach output Power supply 230 VAC / 48 VDC EC fan 48 VDC PWM and Lin 0-10 VDC Linear input: < 1 VDC 1 VDC 10 VDC red 230 VAC, 50 / 60 Hz blue yellow Optional board (built-in): 3 speed steps Control input Lin 0-10 VDC or selector switch Constant air flow PC with interface converter (RS485) RS485 / ebmBUS Commutation electronics 650 W 110 VDC PC with interface converter (RS485) Actual value 0-10 VDC (e.g. pressure, temperature, air flow, air speed, moisture, CO2) Control input Lin 0-10 VDC Potentiometer for set values Tach output Alarm Controller enabling 10-100 VDC 10-253 VAC 518 -> n=0 -> nmin -> nmax PWM input: < 10% PWM -> n=0 10% PWM -> nmin 100% PWM -> nmax white Selector switch EC fans 48 VDC with integrated commutation electronics EC fan EC fans with external commutation electronics 650 W, 110 VDC (rail technology) General information EC fans (motor size 055) with integrated commutation electronics 1~ 115 VAC or 230 VAC 50/60 Hz mains operation AC centrifugal, backward EC fan with integrated electronics AC centrifugal, forward EC fans (motor size 074) with integrated commutation electronics 1~ 100 -130 VAC or 200 -277 VAC 50/60 Hz mains operation Mains operation, 50 / 60 Hz PC with interface converter (RS485) EC centrifugal, backward Control input 0-10 VDC / PWM Actual value input 0-10 VDC Supply for potentiometer 10 V Tach output EC fans (motor size 084) with integrated commutation electronics 1~ 100 -130 VAC or 200 -277 VAC 50/60 Hz mains operation EC centrifugal, forward EC fan with integrated electronics EC centrifugal, backward for clean rooms Slave output Mains operation, 50 / 60 Hz EC-SYSTEMS PC with interface converter (RS485) Control input 0-10 VDC / PWM Actual value input 0-10 VDC Supply for potentiometer 10 V Accessories Alarm 519 Contacts Technology Slave output EC-SYSTEMS Options EC fan with integrated electronics EC fans (motor size 084, ebmBUS) with integrated commutation electronics 1~ 200-277 VAC, 50/60 Hz mains operation Mains operation, 50 / 60 Hz PC with interface converter (RS485) on/off and alarm output 15 V EC fan with integrated electronics Mains operation, 50 / 60 Hz PC with interface converter (RS485) Control input 0-10 VDC / PWM Actual value input 0-10 VDC Actual value input 4-20 mA Supply for external sensor 20 V Supply for potentiometer 10 V Alarm Slave output 520 EC fans (motor size 112/150) with integrated commutation electronics 1~ 200-277 VAC or 3~ 200-240 / 380-480 VAC 50/60 Hz mains operation General information Electronics EC fan EC-SYSTEMS: Networked EC fans with interface converter and repeater AC centrifugal, backward Interface converter and repeater Control software part no. 25711-2-0199 integrated electronics max. 31 addresses Power supply 150 W – Individual control and monitoring of max. 7,905 fans Repeater part no. 25708-1-0174 EC centrifugal, backward Features of control software LISA 5.1 AC centrifugal, forward Interface converter part no. 21487-1-0174 – Group-oriented arrangement of the fans – Level 2: Overview display for 255 groups max. 31 addresses integrated electronics EC centrifugal, backward for clean rooms – Level 1: Overview display for 10 floors – Level 3: Overview display for 31 fans within a group – Broadcast command for a group or all fans – Speed, temperature or pressure control EC centrifugal, forward – Alarm signal integrated electronics Repeater Technology Accessories EC-SYSTEMS max. 31 addresses 521 Contacts Customer PC with LISA 5.1 control software Switch power supply with PFC, basic version 48 VDC, 150 W / 300 W Output voltage Output P1 max. Rated output current Mass Type Frequency Nominal data Nominal voltage – General remarks: Switch power supply with an output power of 150 W / 300 W to supply 48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is available on request. – Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof, open-circuit proof and protected against overheating. An integrated EMC filter guarantees RFI suppression of the unit according to EN 61000-3-2. – Material: Housing made of stainless steel – Protection class: I – Type of protection: IP 20 (acc. to EN 60529) VAC Hz VDC W A kg a b c d e f Dimensions CNW015-AB06 -01 1~ 115 50/60 48 150 3.10 0.7 187 176 167 50 110 1 CNW015-AB02 -01 1~ 230 50/60 48 150 3.10 0.7 187 176 167 50 110 1 CNW030-AC06 -01 1~ 100-120 50/60 48 300 6.25 1.3 272 260 251 66 112 2 CNW030-AC02 -01 1~ 200-277 50/60 48 300 6.25 1.3 272 260 251 66 112 2 subject to alterations f d – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 – Product conforming to standards: EN 50178, CE – Approvals: UL/CSA (File No. E 181381) e 80 108 522 10 a c b 5 blue red EC centrifugal, backward for clean rooms red EC centrifugal, forward PE EC-SYSTEMS N Accessories L Technology +48 GND +48 GND V V blue EC centrifugal, backward Line side Motor side AC centrifugal, forward AC centrifugal, backward Blower 2 exhaust air 523 Contacts Blower 1 exhaust air General information Switch power supply with PFC, RS485 and ebmBUS 48 VDC, 150 W / 300 W Output voltage Output P1 max. Rated output current Mass Type Frequency Nominal data Nominal voltage – General remarks: Switch power supply with an output power of 150 W / 300 W to supply 48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is available on request. – Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof, open-circuit proof and protected against overheating. An integrated EMC filter guarantees RFI suppression of the unit according to EN 61000-3-2. – Material: Housing made of stainless steel – Protection class: I – Type of protection: IP 20 (acc. to EN 60529) VAC Hz VDC W A kg Dimensions a b c d e f CNW015-AB06 -05 1~ 115 50/60 48 150 3.10 0.7 187 176 167 50 110 1 CNW015-AB02 -05 1~ 230 50/60 48 150 3.10 0.7 187 176 167 50 110 1 CNW030-AC06 -05 1~ 100-120 50/60 48 300 6.25 1.3 272 260 251 66 112 2 CNW030-AC02 -05 1~ 200-277 50/60 48 300 6.25 1.3 272 260 251 66 112 2 subject to alterations f d – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-1 – Product conforming to standards: EN 50178, CE – Approvals: UL/CSA (File No. E 181381) – Technical features: Control board for RS485, ebmBUS and LISA functions e 80 108 524 10 a c b 5 N PE red +48 GND +48 GND V V blue EC centrifugal, backward RS485 EC centrifugal, backward for clean rooms L Tach PWM EC centrifugal, forward Motor side EC-SYSTEMS Line side Accessories white Technology yellow RS485 AC centrifugal, forward RS485 Interface converter AC centrifugal, backward Blower 525 Contacts To next switch power supply ~ RS232 2 x RJ45: PIN 5 - RS B PIN 6 - RS A General information External commutation electronics for rail technology, 110 VDC, 650 W Nominal voltage Power input P1 max. Current draw Perm. amb. temp. Mass – General remarks: For EC motors / fans with three cores and without integrated commutation electronics – Function: Commutation unit for three-core ebm EC motors up to a power input of 650 W. Various basic functions are integrated: open loop speed control, closed loop speed control, even an RS485 interface. In combination with sensors, all control tasks as required in air technology can be executed. – Protection class: I – Type of protection: IP 20 (acc. to DIN EN 60529) – NB: Connected fans have to be designed for rated voltage of 127 VDC! Type VDC W A °C kg CEG 485-HB50 -01 110 650 Nominal data 5.9 -25 to +40 2.0 subject to alterations 68 2,2 169 1,5 190 64 63 1,5 40 146,5 526 193 5,5 63 179,5 – EMC / EMI: Acc. to EN 50155 and EN 50121 – Legislation: Low voltage directive 73/23/EEC, VDE 0160/EN 50178 – Design: • motor output protected against short circuit phase to phase and conditionally phase to earth • 0-10 V input (Ri: 100 k) • 0-10 V input (Ri: 100 k) for connection of external actual value input • RS485 interface (ebmBUS) • Floating alarm contact 250 VAC / 5A, during alarm, relay is released (low-active) • Wide voltage input for external controller enabling via RESET function • Tach output • LED for operation and alarm mode green: unit on red: alarm • Setting of minimum and maximum values via potentiometer • Operational modes (to be set via DIP switch): Open loop speed control Closed loop speed control Controlling external parameters • Direction of motor rotation reversible – Connectors for external electronics: KL1 2-pole connector; centreline 7.5; Co. Wago part no.: 231-202/026-000 KL2A 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000 KL2B 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000 KL3A 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000 KL3B 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000 KL4 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000 KL5A 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000 KL5B 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000 KL6 3-pole connector; centreline 7.5; Co. Wago part no.: 731-603 General information AC centrifugal, backward An GND NO COM KL2A KL3A EN + H+ H1 H2 EN - KL4 H- H- H3 U KL5A Connector Connection Assignment / function Connector Connection Assignment / function PE1 Ground connection KL3A PE2 Ground connection KL1 KL2A KL2B KL3B Relay contact for alarm, make for failure Relay contact for alarm NC Relay contact for alarm, break for failure COM Relay contact for alarm EN + Enable input via RESET function EN - Enable input via RESET function H1 Hall-sensor 1 - 110 VDC RS A Interface connection RS A RS B Interface connection RS B RS A Interface connection RS A RS B Interface connection RS B H2 Hall-sensor 2 An, Tacho Tach output, open collector H3 Hall-sensor 3 GND Reference KL2 (for KL2 only) +18 V +18 V (non-stabilised, +20 %, 20 mA) to supply Sensor 1 external sensors Input for external sensor, Ri = 100 k GND +10 V W KL6 COM 110 VDC KL5A V NO + KL4 AC centrifugal, forward Tacho COM EC centrifugal, backward RS B NC PE2 EC centrifugal, backward for clean rooms KL1 RS A GND TW H+ PTC EC centrifugal, forward RS B GND 0-10 V Shielding connection EC-SYSTEMS RS A 1 +10 V Shielding connection KL5B H+ Power supply for hall-sensors (+) H+ Power supply for hall-sensors (+) Reference KL2 (for KL2 only) TW / PTC Thermal switch or PTC connection H- Power supply for hall-sensors (-) 0-10 V +10 V (stabilised +/- 3 %, 25 mA) Input for set value 0 - 10 V, Ri = 100 k H- Power supply for hall-sensors (-) GND Reference KL2 (for KL2 only) U Motor winding U V Motor winding V W Motor winding W KL6 Accessories - Sensor KL5B Technology + +18 V KL3B 527 Contacts KL2B PE1 Output current Output impedance Temperature measuring range Mass 50005-1-0174 Output voltage Part no. Current draw Nominal data Nominal voltage Temperature sensor VDC mA VDC mA k °C kg 15-30 10 0-10 1.0 1.1 -20 to +80 0.02 subject to alterations 3 +0,2 1±0,1 2,5 – Electr. connection: Ø4,9 red 15-30 VDC 8 3,3 Ø7 +0,5 Ø3,5 84,7 yellow 0-10 VDC output 45 37,5 38,5 Output + – (yellow) (red) (blue) Core-end sleeve 450 +20 6,9 5 13 6,5 blue 6 85 Temperature sensor – Output voltage depending on temperature: U/V 10 0 -20 Tolerance ±3 K 528 80 Temp. °C Output current Output impedance Temperature control range Mass VDC mA k °C kg 50002-1-0174 18-60 10 2-10 0.1 6.8 +30 to +55 0.02 50003-1-0174 18-60 10 0-10 0.1 6.8 +10 to +45 0.02 General information EC centrifugal, backward Output voltage mA Part no. EC centrifugal, backward for clean rooms Current draw VDC Nominal data subject to alterations 3 +0,2 Ø4,9 red 18-60 VDC 84,7 yellow 2-10 VDC or 0-10 VDC output 45 37,5 red Maximum ripple ± 3.5 % yellow Control input 0 - 10 VDC Counter 47 K Isink max. 10 mA 6,5 5 Core-end sleeve EC-SYSTEMS (yellow) (red) (blue) 680 Tach output, pulses per revolution Speed display 450 +20 38,5 47 V blue blue GND 6 85 Fans Accessories Connection – Control function: Both designs have "cooling" as control function U/V U/V 10 10 2 1 0 30 55 50002-1-0174 Temp. °C 0 6 10 45 Temp. °C 50003-1-0174 Technology Temperature control module Tolerance ±3 K 529 Contacts Output + – white Alarm 6,9 13 Controller 47 K 1±0,1 2,5 – Electr. connection: 8 3,3 Ø7 +0,5 Ø3,5 EC centrifugal, forward Nominal voltage AC centrifugal, forward AC centrifugal, backward Temperature control module Pressure control with integrated pressure sensor Pressure control range Perm. amb. temp. CCC 000-AC04 -01 Nominal voltage, alternative Type Frequency Nominal data Nominal voltage range – Functions: Integrated PID controller, day/night/linear set point preset, integrated set point potentiometer for day and night, external set point preset via potentiometer – Pressure sensor: 0-500 Pa, bursting strength 200 mbar, for non-aggressive gaseous media – Type of protection: IP 55 – Inlet nozzles: Suitable inlet nozzles to determine airflow, see page 551 VAC Hz VDC Pa °C 50/60 20 @ 50 mA 50-500 -25 to +60 1~ 100-277 subject to alterations 35,5 89,5 167 1,5 10,5 162 195 95±0,2 115 pressure controller 100-277 VAC pressure range IP55 50/60 Hz 0-500 Pa 10 125 43 180±0,4 Ø 5,5 7,5 530 General information AC centrifugal, backward Fan Set value potentiometer Selector switch Day Linear Night Alarm ST8 GND Night GND Day GND +10 V 0-10 V PWM GND OUT Tach GND PE Protective earth ST3 L Mains 50/60 Hz, phase N Mains 50/60 Hz, neutral PE Protective earth L 20 V IN EC centrifugal, backward for clean rooms Connector Connection Assignment / function DC voltage supply (optional), GND Tach Tach output from fan Mains 50/60 Hz, phase OUT Control voltage for fan, 0-10 V N Mains 50/60 Hz, neutral GND GND NC Relay contact for alarm, break for failure +10 V Set value potentiometer, COM Relay contact for alarm NC Relay contact for alarm, break for failure 0-10 V PWM Set value potentiometer COM Relay contact for alarm GND Set value potentiometer Day Selector switch terminal GND Selector switch terminal Night Selector switch terminal GND Selector switch terminal ST4 EC centrifugal, forward with reverse polarity protection GND supply 10 V (-10 %), 10 mA EC-SYSTEMS ST7 Assignment / function Accessories ST2 ST4 Technology ST1 ST3 Line terminals Control terminals Connector Connection 20 V IN COM ST8 EC centrifugal, backward ST7 NC COM NC N L ST2 531 Contacts ST1 PE N L PE AC centrifugal, forward Mains Selection module for 3 speeds – General remarks: Using an external selector switch, one of three preset speeds can be chosen. Presetting is done via one integrated potentiometer each. – Material: Plastics – Type of protection: IP 20 Type CBC 000-AE04 -01 subject to alterations 90 24 50 532 EC centrifugal, backward Connection selector switch +10 V Day Night AC centrifugal, forward GND EC centrifugal, backward for clean rooms 0-10 V output blue EC centrifugal, forward yellow EC-SYSTEMS +10 V Accessories Selector switch red Technology Fan AC centrifugal, backward Connection fan 533 Contacts – Electr. connection: Party General information Interface converter RS232 - RS485 21487-1-0174 1~ 230 VAC / VDC mA 12-24 150 Mass (incl. PS) VAC Current draw at no-load operation Part no. Supply voltage Nominal data Nominal voltage power supply – General remarks: This interface converter permits bi-directional connection of RS232 devices (laptop or PC) with ebmBUS devices (electronic commutation units with RS485 interface) – Safety: Electrical insulation between the RS232 and RS485 side is provided – Material: Plastic housing for standard rail mounting according to DIN EN 50022-35 – Status display: Via LEDs green: supply voltage OK red: data exchange kg 0.4 subject to alterations RS485 M L+ 105 22 RS232 75 534 – Mode of operation: RS485 2-wire mode with echo and automatic control – Galvanic insulation: Min. 1kV insulation voltage between RS232 and RS485 interfaces and between power supply and interfaces – ESD immunity: Up to 15 kV (acc. to IEC 801-2, Stage 4) – Delivery scope: • Interface converter • Plug-in supply unit (230 VAC / 12 VDC, 500 mA) • Adaptor leads with 2 x 9-pole SUB-D sockets • Adaptor leads with 9-pole SUB-D socket • Screw terminal RS485 General information Interface converter RS232 - RS485 Nominal data Part no. kg 21495-2-0174 0.1 EC centrifugal, backward for clean rooms Mass EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – General remarks: This interface converter permits bi-directional connection of RS232 devices (laptop / PDA) with ebmBUS devices (electronic commutation units with RS485 interface) Power supplied by RS232 of the laptop / PDA. – Material: Plastic housing – Status display: Via LEDs PWR: Power supply TXD: Data transfer (send) RXD: Data transfer (receive) TX+ TX- GND RX+ RX- 19 subject to alterations 74 RS485 RS422 EC centrifugal, forward TRX+ TRX- – Mode of operation: RS485 2-wire mode with echo and automatic control – Delivery scope: Interface converter, English-language operating manual – Electrical terminals: Screw terminal, TRX+ = RSA, TRX– = RSB RXD TXD EC-SYSTEMS PWR 535 Contacts Technology Accessories 37 RS485 repeater Perm. operating temp. Perm. storage temp. Mass 25708-1-0174 Power input Part no. Frequency Nominal data Supply voltage – General remarks: The physical RS485 repeater is used for the connection of two segments on an RS485 basis. It can split a segment with network bus wires that are too long, or with too many nodes into two smaller, standardised units. A maximum of 31 nodes can be connected to the repeater. – Installation: The repeater housing is mounted on the wall or in the cable duct with two screws (Ø 4 mm) or with cable ties. – Material: Housing made of galvanised sheet steel – Type of protection: IP 20 according to DIN EN 60529 VAC Hz VA °C °C kg 50/60 <3 1~ 200-277 0 to +50 -20 to +70 0.3 subject to alterations – – – – – Wieland Bamberg screw terminal Bus2 Bus1 Mating connector GST 18/3 Bus2 Bus1 50 38 Type of transceiver: 2 x ANSI standard RS485 transceiver Galvanic insulation: Operating insulation 500 V between both channels Network connection: Screw terminals Mains connection: Wieland connector GST 18/3 (part of delivery) Pin configuration of network: 8765432 1 8765432 1 A A B B BUS1 BUS2 Pin No. Assignment / function 1-4 not assigned 5 Connection RS485, line B 6 Connection RS485, line B 7, 8 not assigned (each looped through within BUS1 and BUS2) 190 200 12 3 4 5 6 7 8 3 LED 30 Ø4 .3 Supply connection 536 12 3 4 5 6 7 8 General information RS485 terminal box with lead connections for centrifugal fans with EC motor size 084 (ebmBUS, RS485) EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – General remarks: RS485 terminal box with • 2x RJ45 socket for ebmBUS • ebmBUS lead with Molex Mini-Fit female connector to connect to motor • 3-pole 4-pin unit connector with AMP Mate-N-Lock female connector to connect to motor • Mode of operation display (LED2 green) and alarm display (LED1 red) – Delivery scope: • Terminal box • Supply line (800 mm) • ebmBUS line (800 mm) – Material: ABS (fire rating V0 according to UL) EC centrifugal, backward for clean rooms Part no. 54002-4-1040 subject to alterations 61.6 45.4 111 99 green/yellow PE black 2 N black 1 L – Pin configuration of ebmBUS lead: Colour Assignment / function yellow RS A white RS B red Operation: +15 V Alarm: blue Operation: 0V 0 V Alarm: +15 V Mounting dimensions Assignment / function 5 RS B 6 RS A Technology 4 88 99 58 Pin No. Accessories – Pin configuration of RJ45 sockets: 61 537 Contacts 87 73 61 Assignment / function EC-SYSTEMS 57 Colour EC centrifugal, forward – Pin configuration of supply lead: Hand-held control terminal Perm. amb. temp. Perm. storage temp. Mass CBC 000-AB06 -01 Supply voltage Type Frequency Nominal data Nominal voltage range power supply – General remarks: Terminal to control networked fans and to set their parameters; RS485 (ebmBUS) – Type of protection: IP 20 (acc. to DIN EN 60529) – Protection class: III – Display: Plain text LCD, 2x8 characters – Accumulator and charging electronics: 2 x round cell R6 DIN 40863 NiMH 1,500 mAh, operating time approx. 40 hrs, standby time approx. 100 days, charging time max. 4 hrs. – Parts included in delivery: Hand-held control terminal, power supply and accumulator unit, BUS cable, 2 x round cell R6 NiMH 1,500 mAh VAC Hz VDC °C °C kg 50/60 12 1~ 100-240 subject to alterations 95 68 538 44 0 to +45 -20 to +65 0.4 Contacts 539 Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward General information Speed setting with housing Resistance Perm. amb. temp. Mass VDC mA k °C kg 10 1.1 0-10 Lin 50 0.10 Supply voltage Max. current draw – Material: Housing made of plastic – Type of protection: IP 54 – Design: The speed setting can be operated with the entire range of ebm-papst EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal that allows infinitely variable open loop speed control. The control also permits fan speed measurement using a multimeter equipped with a frequency meter (for which a tach output is given from the fan). – Cable inputs: 4 x M16 or M20 – Mounting holes: Suitable for 4 mm mounts Nominal data Type CLC 000-AE04 -01 subject to alterations – Speed measurement: Connect a frequency meter to the connection points (labelled + and -) on the PCB board. The fan outputs 1 pulse per revolution, so that the measured frequency can be converted into rpm using the following equation: rpm = frequency (Hz) x 60 – Comment: • A single controller can be used to control multiple fans with the same speed setting. • The connection to the controller is made using four screw connections or one Molex connection (adaptor lead available). • If the tach cable is required, this device can only be connected to a fan. Note that in rare operating cases, it is possible that permanent connection of the tach cable can cause a slight decrease in the maximum speed. 58 26 65 65 50 50 25 + meter connection – meter connection 540 EC centrifugal, backward Fan 1 AC centrifugal, forward Tacho EC centrifugal, backward for clean rooms GND EC centrifugal, forward blue white white Control EC-SYSTEMS red yellow blue Accessories blue red Technology Fan 2 white yellow +10 V Control GND Tacho AC centrifugal, backward +10 V 541 Contacts red yellow – Electr. connection: General information Speed setting without housing Resistance Perm. amb. temp. Mass VDC mA k °C kg 10 1.1 0-10 Lin 50 0.05 Supply voltage Max. current draw – Design: The speed setting can be operated with the entire range of ebm-papst EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal that allows infinitely variable open loop speed control. The control also permits fan speed measurement using a multimeter equipped with a frequency meter (for which a tach output is given from the fan). – Mounting hole: 10 mm Nominal data Type CLC 000-AD04 -01 subject to alterations 36 28 12 22 50 36 28 4 x Ø3,5 + meter connection – meter connection 542 – Speed measurement: Connect a frequency meter to the connection points (labelled + and -) on the PCB board. The fan outputs 1 pulse per revolution, so that the measured frequency can be converted into rpm using the following equation: rpm = frequency (Hz) x 60 – Comment: • A single controller can be used to control multiple fans with the same speed setting. • The connection to the controller is made using four screw connections or one Molex connection (adaptor lead available). • If the tach cable is required, this device can only be connected to a fan. Note that in rare operating cases, it is possible that permanent connection of the tach cable can cause a slight decrease in the maximum speed. EC centrifugal, backward Fan 1 AC centrifugal, forward Tacho EC centrifugal, backward for clean rooms GND EC centrifugal, forward blue white white Control EC-SYSTEMS red yellow blue Accessories blue red Technology Fan 2 white yellow +10 V Control GND Tacho AC centrifugal, backward +10 V 543 Contacts red yellow – Electr. connection: General information LISA Control software for EC-SYSTEMS – Version: LISA 5.1 – Features: • Individual control and monitoring of max. 7,905 fans • Group-oriented arrangement of the fans • Level 1: Overview display for 10 floors • Level 2: Overview display for 255 groups within a floor • Level 3: Overview display for 31 fans within a group • Broadcast command for one group or all fans • Speed, temperature or pressure control • Error message Part no. 25711-2-0199 subject to alterations – Suitable for: EC motors and electronics with ebmBUS – System requirements: Windows 2000 / XP 544 General information Fan Control Control software & accessories for Pocket PCs / PDAs EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Version: Fan Control 1.00 – Features: • Managing up to 31 fans • Setting pre-set values and indicating actual values • Setting parameters for PID control • Setting fan address • Setting mode of operation (heating/cooling) • Alarm diagnosis • Language selection for user interface Graphic setting Accessories Fan address Technology Mode of operation 545 Contacts Set and actual values – Delivery scope: Installation-CD, interface converter (RS232-RS485), BUS cable, installation instruction and detailed manual (PDF). The Pocket PC / PDA and compatible serial communication cables are not included in the scope of delivery. – Suitable for: EC motors and electronics with ebmBUS – System requirements: Pocket PC / PDA with Windows Mobile 5.0, RS232 interface, and serial communication cable. – Compatible Pocket PCs / PDAs: (as of 2006-09-14) • Hewlett-Packard rx1950 • Hewlett-Packard hx2190 • Fujitsu-Siemens Pocket Loox C550 • Dell Axim x51v (624 MHz) Refer to our website at www.ebmpapst.com/downloads for a continuously updated list of approved Pocket PCs / PDAs along with the suitable serial communication cables. EC centrifugal, forward subject to alterations EC-SYSTEMS 21500-1-0174 EC centrifugal, backward for clean rooms Part no. HMS controller Supply voltage Power input(1), max. Power input (2), max. Current draw(1), max. Perm. amb. temp. Mass – General remarks: The HMS controller is governed by a microprocessor and is specifically designed for Heat Management Systems (= HMS). This controller allows for an almost limitless programming variety as regards customer-specific fan speed / temperature profiles. Moreover, this controller offers a multitude of the most diverse alarm configurations. Our HMS controller has been specially designed and adjusted to the product range of ebm-papst in Mulfingen. Thus, any size of our fans or blowers can be used. The most diverse of applications needing temperature-dependent control are possible. Among these are applications in telecommunication and the IT industry, in refrigeration and air-conditioning as well as in specific industrial plants and systems. VDC W W A °C kg 16-57 10 130 Nominal data Type CCC 000-AA05 -03 70 160 75.5 7.25 subject to alterations 546 0.175 -40 to +70 0.15 (1) without fans (2) per fan at nominal voltage 100 81 – Features: • 4 fan speed / temperature characteristics that can be programmed independent of each other • 2 programmable no-frost relays for connection of 115 / 230 VAC heating devices • 5 programmable alarm relays (with time lag): – Temperature alarm (over- / under-temperature) – Fan good / bad alarm programming – Temperature sensor alarm – Programmable depending on signal inputs • 4 programmable status outputs (with time lag): – With "open collector" design to connect optical or acoustic displays / alarms – Each fan speed can be set individually • 4 signal inputs for external switch • Connection of two independent temperature sensors (NTCs) possible • RS232 interface galvanic insulated • Selective protection of each fan • programming via Windows software (terminal program version 15 ff.: part no. 25710-2-0199) – Requirements: • Supply voltage of HMS controller: 16-57 VDC • Fans with standard interface – 24 / 48 VDC fan voltage – PWM / linear control input (0-10 V) – Open collector tach output • NTC with R25 = 33 k (EPCOS type M 891/33k/J) • System requirements: Windows 2000 / XP – Safety: According to EN 50178 – EMC / EMI: Interference immunity EN 61000, interference emission EN 50081-1 General information + * / 250 V PWM Hall F2 3,15 A + Heater 2 N F7 10 A Fan 3 Alarm 3 Alarm 2 K3 K4 + K6 Fan 4 + K7 Status Alarm contact 1 2 3 4 1 2 3 4 NTC 1 NTC 2 1 1 * Hall DTR TD GND RTS 1 1 time lag fuse ê ê PWM Hall F5 3,15 A RD 1 PWM F4 3,15 A Alarm 5 Alarm 4 K5 Hall F3 3,15 A * / 250 V N Alarm 1 PWM 2 4 3 5 7 * / 250 V * / 250 V * / 250 V * / 250 V RS-232 electrically insulated designation 9-pole Sub-D 0-57 V / 10 mA EC centrifugal, backward for clean rooms N Fan 2 EC centrifugal, forward K2 - EC-SYSTEMS F6 10 A Accessories H2 * / 250 V AC centrifugal, forward Fan 1 EC centrifugal, backward F1 3,15 A Heater 1 Technology H1 547 Contacts K1 AC centrifugal, backward - + 16 - 57 VDC L1 548 Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Guard grilles 553 Lead connections, capacitors 558 Terminal boxes, air filters 562 Speed setting, motor protection switch, third-party accessories 564 549 AC centrifugal, backward 550 AC centrifugal, forward Inlet nozzles Contacts General information Accessories Inlet nozzles o – Material: Galvanised sheet steel Vers. 2 Øk Vers. 1 45˚ 118 r1 Vers. 3 5 6x6 t 0˚ 5 242 R14 2,8 Øs Øu 4x90˚ 24 3 4, Øm Øn r3 r2 q 7 5,5 6x6 0˚ Inlet nozzles for backward curved centrifugal fans Part no. Size(1) 96120-2-4013 120 09566-2-4013 133 Vers. k m (P) 1 146.0 94.4 (P) 1 129.0 87.0 09576-2-4013 175 / 190 (P) 1 170.0 09609-2-4013 220 (P) 2 96358-2-4013 225 (P) 1 96359-2-4013 250 (P/S) 96360-2-4013 97512-2-4013 31050-2-4013 310 o q r1 — 18.0 0.80 — 13.0 1.00 125.5 — 14.0 252.0 155.0 — 223.0 146.0 — 1 255.0 164.5 270 / 280 (S) 1 280.0 310 (P) 3 300.0 (A) 1 (2) n r2 r3 s t u 16.0 — 8.0 — — 134.0 4x4.5 126.0 — 118.0 4x4.5 1.25 10.0 103.0 — — 158.0 4x4.5 146.0 21.0 0.80 28.0 1.50 22.0 — — — — 199.0 25.0 — — 210.0 4x4.5 — 31.0 196.0 1.50 28.0 — — 240.0 4x4.5 221.0 182.5 — 192.0 — 35.0 1.50 31.0 — — 260.0 4x4.5 245.0 53.0 1.00 30.0 60.0 — — — 257.0 300.0 211.0 208.1 48.0 1.25 18.0 55.5 35.0 4x4.5 256.0 280.0 31051-2-4013 310 (A) 1 300.0 211.0 209.2 27.5 1.25 10.0 32.0 20.0 280.0 4x4.5 236.0 51357-2-4013 330 / 355 (P) 1 350.0 224.0 — 60.0 1.50 54.0 28.0 — 325.0 4x4.5 284.0 35560-2-4013 355 (A) 1 350.0 240.0 236.4 60.0 1.50 22.5 70.0 44.0 325.0 4x4.5 296.0 325.0 (2) 35561-2-4013 355 (A) 1 350.0 240.0 238.0 30.0 1.50 11.0 35.0 22.0 54476-2-4013 400 (A) 1 370.0 257.0 — 66.0 1.50 22.0 50.0 90.0 345.0 54478-2-4013 450 (A) 1 413.0 287.0 — 71.0 1.50 25.0 55.0 63045-2-4013 450 (A) 1 450.0 289.0 284.5 75.0 1.50 28.0 87.0 49.0 425.0 6x9 360.0 54480-2-4013 500 (A) 1 520.0 323.0 — 79.0 1.50 28.0 65.0 115.0 430.0 6x9 408.0 63072-2-4013 500 (A) 1 470.0 342.0 337.0 75.0 2.00 28.0 87.0 55.0 445.0 6x9 412.0 63071-2-4013 560 (A) 1 515.0 385.0 380.0 82.0 2.00 30.0 95.0 60.0 490.0 6x9 461.0 63070-2-4013 630 (A) 1 634.0 433.0 427.0 98.5 2.00 37.0 14.0 72.0 600.0 6x10.5 525.0 subject to alterations 550 (1) size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium (2) short inlet nozzle 100.0 390.0 4x4.5 267.0 4x4.5 322.0 6x9 362.0 k-value For additional information, refer to p. 550 — 96400-2-4013 250 68 96359-2-4013 — 96410-2-4013 280 80 96360-2-4013 31100-2-4013 31080-2-4013 310 120 31050-2-4013 31110-2-4013 31090-2-4013 310 103 31051-2-4013 35600-2-4013 35580-2-4013 355 155 35560-2-4013 35610-2-4013 35590-2-4013 355 138 35561-2-4013 54515-2-4013 54500-2-4013 400 183 54476-2-4013 54514-2-4013 54510-2-4013 450 217 54478-2-4013 64015-2-4013 64005-2-4013 450 214 63045-2-4013 54518-2-4013 54516-2-4013 500 265 54480-2-4013 64025-2-4013 64002-2-4013 500 283 63072-2-4013 64030-2-4013 64001-2-4013 560 350 63071-2-4013 64040-2-4013 64000-2-4013 630 480 63070-2-4013 General information AC centrifugal, backward EC centrifugal, backward for clean rooms Size EC centrifugal, forward Part no. with 4 nozzles (Piezometer ring) EC-SYSTEMS Part no. with 1 nozzle EC centrifugal, backward Inlet nozzles with measuring device to determine air flow for backward curved centrifugal fans Technology Accessories subject to alterations 551 Contacts D 0,5xD Air flow measurement: The differential pressure approach compares the static pressure before the inlet nozzle with the static pressure inside the inlet nozzle. Air flow can be calculated on the basis of the differential pressure (difference in pressure of the static pressures) in keeping with the following equation: V in [m3/h] and pW in [Pa] V = k . pW If constant air flow control is used, then the nozzle pressure has to be kept constant: pW = V2 : k2 k takes into account the specific nozzle characteristics. 1 or 4 pressure measuring points are spaced along the circumference of the inlet nozzle. Connection on the customer side is accomplished via a premounted T tube connector. This tube connector is suited for pneumatic hoses with an internal diameter of 4 mm. AC centrifugal, forward Inlet nozzles with pressure-measuring point for air flow measurement Inlet nozzles – Material: Galvanised sheet steel Vers. 1 Vers. 2 106 Vers. 3 45˚ 95 0˚ f 6x6 19 4 4x90˚ (2 87 Øu Øb Øa c c 5 4, r 192 ) e d 6x6 e 5,5 0˚ Inlet nozzles for forward curved centrifugal fans Part no. Size Vers. 09560-2-4013 076 / 085 (1) 1 92.0 63.4 09563-2-4013 097 (1) 1 116.0 80.0 09566-2-4013 108 1 129.0 87.0 118.0 09569-2-4013 120 1 142.0 100.0 09572-2-4013 133 1 150.0 112.0 09576-2-4013 140 / 146 1 170.0 (2) a b c d e f r u 84.0 6.0 3x4.2 0.80 6.8 — 108.0 10.0 3x4.5 0.80 10.0 — 13.0 4x4.5 1.00 8.0 — 132.0 9.0 4x4.5 1.00 8.0 — 142.0 12.0 4x4.5 1.00 10.0 — 125.5 158.0 14.0 4x4.5 1.25 10.0 — 09588-2-4013 160 1 185.0 130.0 175.0 17.0 4x4.5 0.75 12.0 — 09597-2-4013 180 3 210.0 149.0 — 28.0 — 1.25 25.0 — 09605-2-4013 200 / 225 2 230.0 175.0 213.0 24.0 6x5.5 1.25 20.0 203.0 25010-2-4013 250 (3) 1 300.0 193.0 285.0 51.5 6x7 1.50 27.3 — 28010-2-4013 280 (3) 1 336.0 228.0 315.0 58.5 6x7 1.50 36.5 296.0 31010-2-4013 310 (3) 1 374.0 257.0 350.0 62.5 6x9 1.50 39.5 327.0 35510-2-4013 355 (3) 1 413.0 289.0 390.0 71.5 6x9 1.50 43.5 372.0 40010-2-4013 400 (3) 1 456.0 325.0 430.0 79.5 6x9 1.50 45.5 414.0 45010-2-4013 450 (3) 1 530.0 365.0 510.0 91.5 6x9 1.50 49.5 459.0 subject to alterations 552 (1) 3 drilled holes staggered by 120° (2) only for 09588-2-1013 (3) 6 drilled holes staggered by 60° General information Guard grille Vers. 2 4x 90 AC centrifugal, backward – Material: Steel wire, plastic coated, silver-metallic gloss ˚ a Ød 20˚ 3x1 Ød AC centrifugal, forward a e e b b Size Vers. a b d e 78130-2-4039 310 1 280.0 4.5 230.0 2.8 78132-2-4039 400 1 345.0 4.5 310.0 2.8 78136-2-4039 450 2 425.0 8.5 350.0 3.8 78139-2-4039 500 2 445.0 8.5 410.0 3.8 78137-2-4039 560 2 490.0 8.5 430.0 3.8 78138-2-4039 630 2 600.0 8.5 490.0 3.8 EC centrifugal, backward for clean rooms Part no. EC centrifugal, backward Guard grille for backward curved centrifugal fans (according to EN 294) Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 553 Contacts Vers. 1 Guard grille – Material: Welded grille made of galvanised steel, frame made of tinned sheet iron 0.4 mm thick a 11 4,5 c Ø100 b (4) Size 160 Guard grilles for centrifugal blowers with single inlet Part no. Size 09489-2-4039 076 / 085 (3) 90.0 74.0 84.0 09490-2-4039 108 126.0 110.0 118.0 09494-2-4039 120 140.0 124.0 132.0 09492-2-4039 140 / 146 168.0 152.0 158.0 09503-2-4039 160 (4) 183.0 170.0 175.0 09493-2-4039 180 (5) 205.0 189.0 194.0 subject to alterations a b (3) 3 drilled holes staggered by 120° c (5) not suitable for G2E180-EH03-01 – Material: Steel wire a c max. e 2 d b Guard grilles for centrifugal blowers with single inlet Part no. Size a b c d e Coating 09603-2-4039 98214-2-4039 076 / 085 101.0 6.0 79.0 4.3 8.0 plastic coated, silver-metallic gloss 108 120.0 3.5 88.0 4.3 8.0 plastic coated, silver-metallic gloss 25028-2-4039 140 / 146 162.0 8.5 139.0 4.3 8.0 galvanised, chromatised in blue 17729-2-4039 160 175.0 3.5 139.0 4.6 7.0 galvanised, chromatised in blue 09526-2-4039 180 (6) 194.0 39.5 164.0 4.3 8.0 phosphated, plastic coated in RAL no. 9005 subject to alterations 554 (6) only suitable for G2E180-EH03-01 General information Guard grille AC centrifugal, forward 3x1 20˚ max. 8 a AC centrifugal, backward – Material: Steel wire b 2 4,3 c a b c 83319-2-4039 097 (1) 96.0 3.5 71.0 phosphated, plastic coated in RAL no. 9005 09485-2-4039 097 (2) 114.0 3.5 88.0 phosphated, plastic coated in RAL no. 9005 09500-2-4039 133 / 146 145.0 4.0 122.0 phosphated, plastic coated in RAL no. 9005 31003-2-4039 180 192.0 9.5 174.0 phosphated, plastic coated in RAL no. 9005 95644-2-4039 200 250.0 5.0 206.0 plastic coated, silver-metallic gloss (1) for D2E097-CH (2) for D2E097-B* – Material: Phosphated steel wire, plastic coated, silver-metallic gloss b EC-SYSTEMS 3x1 2 0˚ max. 8 a subject to alterations Coating EC centrifugal, backward for clean rooms Size EC centrifugal, forward Part no. EC centrifugal, backward Guard grilles for centrifugal blowers with dual inlet d e c 35000-2-4039 160 62226-2-4039 180 62227-2-4039 a b c d e 182.0 12.0 144.0 2.4 4.5 192.0 9.0 173.0 3.0 5.2 200 213.0 9.0 190.0 3.0 5.2 62228-2-4039 225 / 240 242.0 9.0 222.0 3.0 5.2 25825-2-4039 250 275.0 9.0 255.0 3.0 5.2 Technology Size subject to alterations 555 Contacts Part no. Accessories Guard grilles for centrifugal blowers with dual inlet (versions with EW motor) Guard grille 133 – Material: PA plastic 6.6 GV25 V0, black – Special feature: Triangular, raised contour – Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D4E146-LV 13 31 Guard grilles for blowers with dual inlet with plastic housing (cable exit side of blower) Part no. 34265-2-2929 subject to alterations 133 – Material: PA plastic 6.6 GV25 V0, black – Special feature: Outer two rings are closed – Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D4E146-LV; K4E146-AB 13 31 Guard grilles for blowers with dual inlet with plastic housing (side of blower opposite cable exit) Part no. 38182-2-2929 subject to alterations 556 General information Guard grille a AC centrifugal, backward – Material: Phosphated steel wire, plastic coated in RAL no. 9005, black 0˚ 6x6 c AC centrifugal, forward b max. 8 a b c 09513-2-4039 200 250.0 227.0 6.0 09518-2-4039 250 295.0 265.0 7.0 09532-2-4039 300 380.0 323.0 9.0 EC centrifugal, backward for clean rooms Size Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 557 Contacts Part no. EC centrifugal, backward Guard grilles (e.g. for axial fans) Connection leads AMP Universal Mate-N-Lok, suitable for: Connector shell AMP 926 682-3 Plug pin AMP 926 886-1 Jacketed cable, internal leads H03VV-F6G0.5 black Brass lead tips 6 85 – Suitable for: D2E140-HR; D2E146-KA; D2E146-KB; D2E146-HR; D2E146-HS; D2E146-HT; D2E160-FI; D2E160-FK – Plug assignment: 1 = Step 1 (white) 2 = Step 2 (red) 3 = Step 3 (grey) 4 = Step 4 (black) 5= N (blue) 6 = PE (green/yellow) a Lead connections for centrifugal blowers Part no. a 21956-4-1040 300.0 21957-4-1040 450.0 21958-4-1040 650.0 21959-4-1040 1000.0 subject to alterations AMP Universal Mate-N-Lok suitable for: Connector shell AMP 927 231-3 Plug pin AMP 926 886-1 Jacketed cable, internal leads H03VV-F6G0.5 black Brass lead tips 6 85 a Lead connections for centrifugal blowers Part no. a 21810-4-1012 450.0 21811-4-1012 1050.0 21812-4-1012 1300.0 21813-4-1012 1600.0 21814-4-1012 2300.0 subject to alterations 558 – Suitable for: D4E146-LV; K4E146-AB – Plug assignment: 1 = Step 1 (white) 2 = Step 2 (red) 3 = Step 3 (grey) 4 = Step 4 (orange) 5 = Step 5 (black) 8 = N (blue) 9 = PE (green/ yellow) General information Connection leads AMP Mate-N-Lok female connector AC centrifugal, backward – Plug assignment: 1 = N (black 2) 2 = L (black 1) 3 = PE (green / yellow) AC centrifugal, forward Core-end sleeves 8 85 800 EC centrifugal, backward Line lead for EC centrifugal fans (clean room technology) Part no. 22243-4-1029 Core-end sleeves – Plug assignment: 1 = RSB (white) 2 = RSA (yellow) 3 = +15 V (red) 4 = 0V (blue) EC centrifugal, forward Molex Mini-Fit female connector EC centrifugal, backward for clean rooms subject to alterations 8 85 EC-SYSTEMS 800 Control line for EC centrifugal fans (clean room technology) Part no. 22242-4-1029 559 Contacts Technology Accessories subject to alterations Capacitors b c ±10 7 ±1 Øa M8 10 MKP motor capacitors (without fuse) Part no. Capacity a b (max.) c 02100-4-7320 1.0 µF 25-28 58.0 235.0 99282-4-7320 1.5 µF 25-28 58.0 235.0 99283-4-7320 2.0 µF 25-28 58.0 235.0 02103-4-7320 2.5 µF 25-28 70.0 235.0 68462-4-7320 3.0 µF 25-28 70.0 235.0 99284-4-7320 4.0 µF 28-32 58.0 235.0 02101-4-7320 5.0 µF 30-36 70.0 235.0 99285-4-7320 6.0 µF 30-36 70.0 235.0 66788-4-7320 7.0 µF 30-36 72.0 100.0 99286-4-7320 8.0 µF 35-40 72.0 235.0 99287-4-7320 10.0 µF 35-40 72.0 200.0 66786-4-7320 12.0 µF 40.0 72.0 100.0 30457-4-7320 14.0 µF 40-45 92.0 150.0 50090-4-7320 16.0 µF 35-40 95.0 100.0 90034-4-7320 20.0 µF 40.0 95.0 235.0 90025-4-7320 25.0 µF 40.0 120.0 235.0 subject to alterations 560 – Material: Housing made of Thermoplast – Connection lead: Multi-lead PVC cable 0.5 mm2 with brass lead tips – Approval: VDE according to DIN EN 60252 (VDE 0560/8) – Calculated life time: 400 V; -25 to +85°C; 30,000 hrs; class A 450 V; -25 to +85°C; 10,000 hrs; class B General information – Material: Plastic cap, aluminium cup – Designation: FPU or P2 according to IEC 252 (non-flammable, non-explosive, circuit-breaking) – Approval: VDE according to DIN EN 60252 (VDE 0560/8) – Calculated life time: 420 V; -25 to +85°C; 30,000 hrs; class A 470 V; -25 to +85°C; 10,000 hrs; class B 500 V; -25 to +85°C; 3,000 hrs; class C Øa M8 Ø a + 3,5 b 7 ±1 35 +5 235 +10 -5 a b (max.) c (max.) 02151-4-7320 1.0 µF 25-30 77.0 92.0 02155-4-7320 1.5 µF 25.0 77.0 92.0 02156-4-7320 2.0 µF 25.0 77.0 92.0 02159-4-7320 2.5 µF 30.0 71.0 92.0 02160-4-7320 3.0 µF 30.0 71.0 92.0 02161-4-7320 4.0 µF 25-30 104.0 135.0 02162-4-7320 5.0 µF 25-30 104.0 113.0 02163-4-7320 6.0 µF 30.0 101.0 110.0 02164-4-7320 7.0 µF 30-35 101.0 110.0 02165-4-7320 8.0 µF 30-35 102.0 111.0 02166-4-7320 10.0 µF 35.0 96.0 110.0 02167-4-7320 12.0 µF 35.0 96.0 110.0 90026-4-7320 14.0 µF 40.0 130.0 139.0 02168-4-7320 16.0 µF 40.0 96.0 130.0 02169-4-7320 20.0 µF 40.0 116.0 130.0 02170-4-7320 25.0 µF 40-45 116.0 130.0 EC centrifugal, backward for clean rooms Capacity EC centrifugal, forward Part no. EC centrifugal, backward MKP motor capacitors FPU or P2 (with fuse) AC centrifugal, backward c 10 AC centrifugal, forward Capacitors EC-SYSTEMS Accessories Technology – Pull-off protector: The housing expands by max. 9 mm. The protector responds to overload by the generated excess pressure snapping off the internal lead in a predetermined breaking point. – Mounting: c is the overall dimension of the capacitor which has to be taken into account when mounting the part. The capacitor design, however, depends on the manufacturer. The expansion (9 mm) is either added to dimension b, or it is already integrated in the capacitor. 561 Contacts max. 9 mm subject to alterations Terminal box = 91,5 b 58 12 29 94 Øa c 56 = 3 18 27,5 Terminal box Part no. AC motor a b c 64442-1-7612 64444-1-7612 068 (4 poles) 22.0 5.0 4.3 068 (7 poles) 22.0 5.0 4.3 64443-1-7612 074 (4 poles) 12x14.5 10.5 5.5 64445-1-7612 074 (7 poles) 12x14.5 10.5 5.5 subject to alterations 562 – Material: ABS – Description: Two-piece terminal box for AC motors of size 068 or 074, terminal strip with 4- or 7-pole. Suitable for installation of capacitor with 10 µF max. – Type of protection: IP 54 General information Air filter c b AC centrifugal, backward – Material: Steel wire / sheet steel, plastic coated in RAL no. 9005, black – Filter: Viledon filter type R: PSB / 29 OS (according to DIN 24185) Separation capacity: < 86 % Efficiency: < 20 % Dust binding capacity: 650 g/m2 e AC centrifugal, forward d a 95777-1-5171 108 / 120 95778-1-5171 140 / 146 / 160 95347-1-5171 180 a b c d 142.0 66.0 83.0 118-132 145.0 95779-1-5171 185.0 74.0 91.0 158-175 185.0 95780-1-5171 210.0 74.0 91.0 194.0 e 185.0 Spare filter 95780-1-5171 EC centrifugal, backward for clean rooms Size Technology Accessories EC-SYSTEMS EC centrifugal, forward subject to alterations 563 Contacts Part no. EC centrifugal, backward Air filters for centrifugal blowers (with die-cast aluminium housing) Speed setting, 3-phase (with 5 steps) for wall assembly Current draw Mass Type Frequency Nominal data Nominal voltage – Technical features: Input for TOP – Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC – Type of protection: IP 20 (with vertical installation) VAC Hz A kg TCD 020-AA01 -05 3~ 400 50/60 2.0 9.5 TCD 040-AA01 -05 3~ 400 50/60 4.0 13.9 TCD 070-AA01 -05 3~ 400 50/60 7.0 19.7 subject to alterations 166 189 4xØ5,5 185 266 189 224 309 304 564 General information Speed setting, single-phase (with 5 steps) for wall assembly Hz A kg TCE 021-AA01 -05 1~ 230 50/60 2.1 3.6 TCE 040-AA01 -05 1~ 230 50/60 4.0 4.8 TCE 075-AA01 -05 1~ 230 50/60 7.5 6.5 EC centrifugal, backward Mass VAC EC centrifugal, backward for clean rooms Current draw Type Frequency Nominal data Nominal voltage AC centrifugal, forward AC centrifugal, backward – Technical features: Input for TOP – Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC – Type of protection: IP 40 subject to alterations EC-SYSTEMS Accessories 147 167 86 4xØ7 EC centrifugal, forward 144 200 565 Contacts Technology 154 204 Motor protection switch, 3-phase for assembly inside a cabinet Current draw Mass Type Frequency Nominal data Nominal voltage – Technical features: Input for TOP VAC Hz A kg Auxiliary contactor TPD 250-AB01 -01 3~ 400 50/60 25.0 0.3 without auxiliary contactor TPD 250-AB01 -02 3~ 400 50/60 25.0 0.3 with break contact TPD 250-AB01 -03 3~ 400 50/60 25.0 0.3 with make contact subject to alterations 68 – Electr. connection: 7 566 54,5 66,5 General information Motor protection switch, single-phase for assembly inside a cabinet Current draw Mass VAC Hz A kg Auxiliary contactor TPE 100-AB01 -01 3~ 230 50/60 10.0 0.3 without auxiliary contactor TPE 100-AB01 -02 3~ 230 50/60 10.0 0.3 with break contact TPE 100-AB01 -03 3~ 230 50/60 10.0 0.3 with make contact EC centrifugal, backward for clean rooms Frequency Type Nominal voltage Nominal data EC centrifugal, backward AC centrifugal, forward AC centrifugal, backward – Technical features: Input for TOP subject to alterations 52,5 EC-SYSTEMS 45 Technology Accessories 70 78 567 Contacts 103 46 EC centrifugal, forward – Electr. connection: Motor-protection switch, single phase and three-phase for wall assembly Current draw Mass Type Frequency Nominal data Nominal voltage – Technical features: Input for TOP – Type of protection: IP 55 VAC Hz A kg Auxiliary contactor TPD 250-AA01 -01 3~ 400 50/60 25.0 0.6 without auxiliary contactor TPD 250-AA01 -02 3~ 400 50/60 25.0 0.6 with break contact TPD 250-AA01 -03 3~ 400 50/60 25.0 0.6 with make contact TPE 100-AA01 -01 1~ 230 50/60 10.0 0.6 without auxiliary contactor TPE 100-AA01 -02 1~ 230 50/60 10.0 0.6 with break contact TPE 100-AA01 -03 1~ 230 50/60 10.0 0.6 with make contact subject to alterations 92 80 141 79 38 568 – Electr. connection, three-phase: – Electr. connection, single-phase: 20 General information Star-delta switch / repair switch Third-party accessories from Möller Electric GmbH AC centrifugal, forward AC centrifugal, backward More information: www.moeller.net for wall installation Designation Installation T0-4-8410/I1 Wall installation T0-4-8410/E Cabinet installation EC centrifugal, backward Star-delta switch (available from Möller Electric GmbH) EC centrifugal, backward for clean rooms subject to alterations EC centrifugal, forward More information: www.moeller.net EC-SYSTEMS for wall installation Repair switch, lockable (available from Möller Electric GmbH) Designation Installation T0-2-8900/I1/SVB-SW Wall installation T0-2-8900/EA/SVB-SW Cabinet installation 569 Contacts Technology Accessories subject to alterations 570 Technology Accessories EC-SYSTEMS EC centrifugal, forward EC centrifugal, backward for clean rooms EC centrifugal, backward Impellers 576 Motors 590 Control technology 594 571 AC centrifugal, backward 572 AC centrifugal, forward Technical parameters & scope Contacts General information Technology Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors: are listed on the product-specific data sheet. – The service life of the insulation system – The service life of the bearing system Type of protection The service life of the insulation system mainly depends on voltage level, The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation. The service life of the bearing system depends mainly on the thermal load Insulation class on the bearing. The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for any mounting position possible. As an option, sleeve bearings can be Mounting position used, which is indicated on the product-specific data sheet wherever The mounting position is specified in the product-specific data sheets. applicable. The service life L10 of the ball bearings can be taken as approx. 40,000 Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions. product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account your specific operating conditions. Mode of operation The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection Information on motor protection and thermal protection is provided in the Protection class product-specific data sheets. The protection class is specified in the product-specific data sheets. Depending on motor type and field of application, the following protective features are realised: – Thermal overload protection (TOP), either in-circuit or external – PTC with electronic diagnostics – Impedance protection – Thermal overload protection (TOP) with electronic diagnostics – Current limitation via electronics If an external TOP is connected, the customer has to make sure to connect a conventional trigger device for switching it off. All fans with 1~ AC voltage are equipped with a TOP that is connected in the winding circuit. Products without fitted TOP and without protection against improper use, a motor protection complying with the valid standards has to be installed. 572 General information AC centrifugal, backward AC centrifugal, forward Legal and normative directives All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application. Vibration test Standards Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets. – Vibration test in operation according to DIN IEC 68, parts 2-4 EMC Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final – Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC properties. Testing the balancing quality is carried out in compliance with Leakage current – Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific – Standard balancing quality level G 6.3 data sheets. Should you require a higher balancing quality level for your specific The measurement takes place according to Fig. D.1 according to application, please let us know and specify this when ordering your IEC 60990, Fig. 4. EC-SYSTEMS Balancing quality product. In case you require a specific approval for your ebm-papst product Should you have questions about chemo-physical strain, please direct (VDE, UL, GOST, CCC, CSA, etc.) please let us know. them to your ebm-papst contact. Most of our products can be supplied with the relevant approval. Accessories Approvals Chemo-physical strain / performance parameters Information on existing approvals is provided in the product-specific Fields of application, industries and applications data sheets. Our products are used in various industries and applications: Ventilation, air-conditioning and refrigeration technology, clean room Air performance measurements technology, automotive and rail technology, medical and laboratory tech- All air performance measurements are carried out on inlet-side chamber nology, electronics, computer and office technology, telecommunications, test rigs in conformity with the requirements of DIN 24163 and ISO 5801. household appliances, heating, machines and plants, drive engineering. The fans being tested are installed on the measuring chamber at free air Our products are not designed for use in the aviation and aerospace intake and discharge (installation type A according to DIN 24163 Part 1) industry! and are operated at nominal voltage (for AC, also at nominal frequency) Technology sheets. EC centrifugal, forward Information on EMC standards is provided in the product-specific data Shock load without additional attachments such as the guard grille. As required by the standard, the air performance curves correspond to an air density of 1.2 kg/m3. 573 Contacts – Vibration test at standstill according to DIN IEC 68, parts 2-4 EC centrifugal, backward Mechanical strain / performance parameters EC centrifugal, backward for clean rooms Left: Endurance test room Middle: Shock test Right: Chamber test rig Room for precision noise measuring Measurement conditions for air and noise measurement ebm-papst products are measured under the following conditions: – Axial and centrifugal fans with direction of air flow "V", without guard grille and in the wall ring – Backward curved centrifugal fans, free-running and with inlet nozzle – Forward curved single and dual inlet centrifugal fans with housing Noise measurements All noise measurements are carried out in low-reflective test rooms with reverberant floor. Thus the ebm-papst acoustic test chambers meet the requirements of precision class 1 according to DIN EN ISO 3745. For noise measurement, the fans being tested are placed in a reverberant wall and operated at nominal voltage (for AC, also at nominal frequency) without additional attachments such as the guard grille. Sound pressure level and sound level All noise levels are measured in conformity to DIN 45635 and ISO 3744/3745 according to precision class 2 and specified A-weighted. When the sound pressure level (Lp) is measured, the microphone is on the intake side of the fan being tested, usually at a distance of 1 m on the fan axis. To measure the sound level (Lw), 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested D from the sound pressure level by adding 7 dB. 1,5d (see graphic). The sound level measured can be roughly calculated Measurement configuration according to DIN 45635 T38: 10 measuring points d≥D h Measurement area S = 6d2 + 7d (h + 1.5d) 3d h = 1.5d to 4.5d 2d 574 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward 15 Adding multiple noise sources with the same level [dB] Curves The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A). 10 EC centrifugal, backward for clean rooms sheet, the sound pressure level of a fan is approximately 75 dB(A). 1 2 5 8 10 15 20 25 EC centrifugal, forward Example: 8 A3G800 axial fans are on a condenser. According to the data 9 sheet. This is shown in the diagram opposite. 5 be determined in advance based on the noise values specified in the data 0 of approx. 3 dB. The noise characteristics of multiple identical fans can Increase in sound pressure / sound power level Adding 2 noise sources with the same volume results in a level increase 3 Adding two noise sources with different levels [dB] Number of sources of sound with identical level be read in the diagram as approx. 1.5 dB. This means that the overall sound level of the unit can be expected to be 76.5 dB(A). 2 EC-SYSTEMS a ventilation unit. The level difference is 4 dB. The level increase can now 0 4 8 12 16 20 24 [dB] 0 Inverse square laws [dB] Difference in level with two sources of sound Accessories 75 dB(A) at the operating point and an axial fan A3G710 with 71 dB(A) in 1,5 Example: There is an axial fan A3G800 with a sound pressure level of 1 diagram opposite. 0 based on the sound levels given in the data sheet. This is shown in the Increase in sound pressure / sound power level The acoustic performance of two different fans can be predetermined The sound level is independent of the distance from the noise source. -10 Conversely, the sound pressure level decreases as distance from the noise source increases. The diagram to the right shows the level decrease reduction of 26 dB for the 20 m distance. -20 -26 Technology a distance of 20 m. In the diagram to the right, you can now read a 1 Distance 2 5 10 20 50 100 [m] 575 Contacts the operating point. Now, you want to measure the noise characteristics at -30 Example: An axial fan A3G800 has a sound pressure level of 75 db(A) at -40 the noise source under far-field conditions. Decrease in sound pressure level expressed in terms of an output measurement at a distance of 1 m from Impellers Impellers made by ebm-papst Like pumps and compressors, fans and blowers belong to the category of aerodynamic and fluid work machines. A fan consists of an impeller, a drive motor and a housing for suspension and for guiding the air flow. The blades spaced along the circumference of the impeller are designed in such a way as to cause the flowing work medium to change direction, thus passing on pressure and speed energy. ebm-papst construction designs Application-specific selection parameters Depending on the geometrical shape of the impeller, there are different When selecting an application-specific fan or blower, the main parameters construction designs, with their names taken from the main flow to be taken into account are these: direction in the impeller. – Air flow at given back pressure – Constructional design The most important designs are: – Speed/rpm – Axial fans – Impeller diameter – Centrifugal fans with backward curved blades – Ambient conditions governing suction and exhaust side – Single or dual inlet centrifugal blowers with forward curved blades – Diagonal (mixed flow) fans (a cross between axial and centrifugal fans) Relevant fields of application of the various construction designs The different ebm-papst fan and blower designs correspond to the different fields of application: – Small back pressures: axial fans – High back pressures: centrifugal fans with backward curved blades and single or dual inlet centrifugal blowers – Threshold between axial and centrifugal fans: diagonal fans [Pa] Characteristic curves of the various designs axial fans centrifugal fans, backward curved centrifugal blowers, single inlet centrifugal blowers, dual inlet diagonal fans 1200 1000 800 600 400 200 200 576 500 1000 2000 5000 10000 20000 50000 [m³/h] General information AC centrifugal, backward AC centrifugal, forward Axial fans Operating range EC centrifugal, backward Noise / efficiency curve [%] [Pa] – Maximum efficiency – Minimal noise [dB(A)] To the right of the "saddle" (right part of the air performance curve): To the left of the "saddle" (left part of the air performance curve): EC centrifugal, backward for clean rooms – Stall area – Drop in efficiency – Soaring noise The optimum operating range of the fan is shaded in green in the curve given here. optimum operating range EC centrifugal, forward 0 stall area 0 [m³/h] Direction of air flow EC-SYSTEMS The direction of air flow is given as follows: Accessories Direction of air flow "V" Direction of air flow "A" Technology "A" 577 Contacts "V" Effects when mounted in wall ring or in the aperture Curve [Pa] performance in the operating range. [%] Mounting the fan in a wall ring can significantly increase the air 1 1 Wall ring 2 Aperture 2 1 0 2 0 [m³/h] Effects with axial position in the wall ring Curve [Pa] [%] Axial position in the wall ring influences air performance and efficiency. 1 Projecting on inlet side x/D=7% 2 Flush on inlet side x/D=0% 3 2 Immersed on inlet side x / D = -7 % 1 x x 3 x D D D 1 2 0 3 0 [m³/h] 578 General information AC centrifugal, backward AC centrifugal, forward Effects with guard grilles EC centrifugal, backward Curve [Pa] [%] Mounting a guard grille reduces the air performance of the axial fan. With guard grille 1 2 1 EC centrifugal, forward 0 2 EC centrifugal, backward for clean rooms Without guard grille 2 0 [m³/h] V in [m3/h] For the guard grilles used at ebm-papst, the correction factor GG can be used depending on the impeller diameter D from the table to the right. Correction factor GG 130 10000 143 6600 180 2550 200 1650 250 650 300 300 315 240 350 150 400 90 450 55 500 35 560 20 630 11 710 6 800 3 910 1.5 990 0.9 EC-SYSTEMS ∆pGG = GG . 10-8 . V2 Diameter D Accessories following equation: Technology The pressure drop in Pa can be roughly calculated according to the 579 Contacts 1 Effects of obstructions on the suction or exhaust side Curve Disturbances or obstructions on the suction or pressure side reduce [Pa] the air performance of the axial fan. 1 Obstructions on the inlet side 1 x/D= 2 x / D = 35 % 3 x / D = 18 % 4 x/D= 9% 5 x/D= 5% D X 2 3 4 0 5 0 [m³/h] 1 x/D= 2 x / D = 35 % 3 x / D = 18 % 4 x/D= 9% 5 x/D= 5% X D [Pa] Obstructions on the exhaust side 2 4 3 1 0 5 0 [m³/h] 580 General information AC centrifugal, backward AC centrifugal, forward Centrifugal fans with backward curved blades Operating range EC centrifugal, backward Noise / efficiency curve [%] [Pa] – Maximum efficiency – Minimal noise [dB(A)] Middle part of air performance curve: To the right and the left of the middle part of the air performance curve: EC centrifugal, backward for clean rooms – Reduced efficiency – Increasing noise The optimum operating range of the fan is shaded in green in the curve given here. EC centrifugal, forward 0 optimum operating range 0 [m³/h] Effects of nozzle gap dimension Curve s / D = 0.4 % 2 s / D = 1.0 % 3 s / D = 1.4 % [%] [Pa] 3 2 1 3 2 1 Accessories 1 0 D S influences the air performance and efficiency of the centrifugal fan. EC-SYSTEMS The centrifugal air gap between the inlet nozzle and impeller cover plate 0 581 Contacts Technology [m³/h] Effects of overlapping dimension Curve [%] influences the air performance and efficiency of a centrifugal fan. [Pa] The axial overlap between the inlet nozzle and impeller cover plate 1 2 X 1 x / D = 0.6 % 2 x/D= 0 % 3 x / D = -0.8 % 3 1 2 0 D 3 0 [m³/h] Effects of installation space Curve When mounting our product in a rectangular box, air performance 0,99 1,00 might be reduced. 0,95 0,94 0,93 0,92 Correction factor for air flow D D 0,5xD H 0,96 0,97 0,98 B 1,4 1,6 1,8 Hydraulic diameter dh/D dh = Hydraulic diameter Formula: dh = 2 x B x H / (B + H) B = Width of box H = Height of box D = Outer diameter of the fan 582 2,0 2,2 2,4 2,6 2,8 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward Air flow measurement for inlet nozzles with pressure-measuring point The differential pressure approach compares the static pressure before EC centrifugal, backward for clean rooms the inlet nozzle with the static pressure inside the inlet nozzle. EC centrifugal, forward D 0,5xD Air flow can be calculated on the basis of the differential pressure (difference in pressure of the static pressures) in keeping with the W V in [m3/h] and ∆pW in [Pa] EC-SYSTEMS following equation: V = k . ∆p If constant air flow control is used, then the nozzle pressure has to be kept constant: ∆pW = V2 : k2 k takes into account the specific nozzle characteristics. One or four pressure measuring points are spaced along the Accessories circumference of the inlet nozzle. Connection on the customer side is accomplished via a premounted T tube connector. This tube connector 583 Contacts Technology is suited for pneumatic hoses with an internal diameter of 4 mm. Single and dual inlet centrifugal blowers with forward curved blades The forward curved centrifugal impeller must always be operated inside a scroll housing. A dual inlet centrifugal blower shows the same behaviour as two single inlet blowers operated in parallel: with size, speed and pressure being identical, double the air flow is achieved. Operating range Noise / efficiency curve [%] [Pa] – Maximum efficiency – Minimal noise – higher performance density than with the backward curved centrifugal fan To the right and the left of the middle part of the air performance curve: – Reduced efficiency – Increasing noise The optimum operating range of the fan is shaded in green in the curve given here. 0 optimum operating range 0 [m³/h] Dimensioning of the scroll The dimensions of a typical scroll can be calculated with the following formulae, subject to the impeller diameter D: A = 1.062 · D J B = 0.992 · D B A K C = 0.922 · D 45˚ 45˚ H 26˚ C 45˚ 45˚ 45˚ 45˚ F D E G R D = 0.853 · D E = 0.784 · D F = 0.715 · D G = 0.646 · D H = 0.612 · D J = 0.720 · D K = 0.689 · D R = 0.073 · D Adjusting the dimensions to diminished mounting spaces is possible. 584 [dB(A)] Middle part of air performance curve: General information AC centrifugal, backward AC centrifugal, forward Effects of step diffusers EC centrifugal, backward Curve without step diffuser 2 with step diffuser 1 2 EC centrifugal, backward for clean rooms 1 [Pa] increases air performance and efficiency of the centrifugal blower. [%] A diffuser mounted on the exhaust side with connected exhaust tunnel 1 EC centrifugal, forward 0 2 0 [m³/h] Effects of obstructions on the intake side Curve x / D = 30 % 3 x / D = 23 % 4 x / D = 15 % 5 x / D = 7.5 % Accessories x/D= 2 X 5 4 3 2 1 0 0 [m³/h] Technology X 1 585 Contacts D [Pa] centrifugal blower. EC-SYSTEMS Obstructions on the air intake side reduce the air performance of the Effects caused by obstructions on the inlet side for constant air flow EC centrifugal blowers Constant air flow is attained with unimpaired inflow only. An obstructed (e. g. asymmetrical or partially blocked) air flow can have a significant effect on the curve behaviour and cause large deviations from a constant air flow curve. Examples of obstructed inflows X Instructions for designing a sufficiently unobstructed inflow: – The distance x between the blower intake and neighbouring walls or obstructions should be at least 25 % of the impeller diameter. – Inflows with angular momentum or asymmetrical rotation should be avoided. – The inflow can be made more uniform using resistances such as those from filters or grilles. On request, we offer calibrated blower designs that incorporate a specific installation situation. 586 General information AC centrifugal, backward AC centrifugal, forward Diagonal fans (axial design) Noise / efficiency curve EC centrifugal, backward Operating range [%] [Pa] performance curve): – Maximum efficiency [dB(A)] Directly to the right of the "saddle" (right part of the air – Minimal noise EC centrifugal, backward for clean rooms To the left of the "saddle" (left part of the air performance curve): – Stall area – Drop in efficiency – Soaring noise The saddle of the diagonal / mixed flow fan is slightly higher than that of the axial fan. This means that the technical ratings in the optimal optimum operating range EC centrifugal, forward The optimum operating range of the fan is shaded in green in the stall area 0 operating range are better than those of the axial fan. 0 [m³/h] curve given here. Mounting information EC-SYSTEMS The conical housing (part of delivery) makes sure the necessary gap dimension is kept. Effects The effects of the diagonal / mixed flow fan are similar to those listed 587 Contacts Technology Accessories for the axial fan (p. 577-580). Dimensioning / change in speed A change in speed influences: 140 – Air flow V 120 [%] Influence of speed n 160 Curve V~n 1.4n 1.3n 100 1.2n n 80 – Static pressure increase pfa 1.1n ∆pfa ~ n2 0.9n 60 – Requirement of energy P1 0.8n 0.7n 40 P1 ~ n3 0 20 0.6n 0 20 40 60 80 100 120 140 [%] Influence of the speed n on the sound level Lw [dB] Curve 20 When the speed changes, the approximate sound level can be determined using the diagram to the right and the following formula: Lw - Lw = 50 dB . log (n : n ) n1 = Changed speed n2 = Starting speed 0 Lw1 = Sound level after speed change Lw2 = Sound level before speed change 10 1 -10 2 -20 1 modification in sound pressure level 2 0,5 1 factor of speed change 588 1,5 2 2,5 3 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward 1.2D 120 – Air flow V 1.1D 100 D3 – Static pressure increase ∆pfa D 80 ∆pfa ~ D2 EC centrifugal, backward for clean rooms A change in impeller diameter influences: V~ 160 1.3D 140 Influence of impeller diameter D [%] Curve 0.9D 60 – Requirement of energy P1 0.8D 0.7D 40 P1 ~ D5 0 20 0.6D 20 40 60 80 100 120 140 EC centrifugal, forward 0 [%] V~b 140 160 EC-SYSTEMS – Air flow V 120 A change in width of the air discharge influences, in approximation: 100 Influence of width of air discharge b (only for centrifugal impellers) [%] Curve 1.1b b Accessories 60 40 0.7b 0.9b 0.6b 0.8b 1.3b 1.2b 1.4b 20 20 40 60 80 100 120 140 [%] Technology 0 589 Contacts P1 ~ b 0 ∆pfa = const – Requirement of energy P1 80 – Static pressure increase ∆pfa Motors Motors made by ebm-papst In AC and EC technology, ebm-papst relies on the proven external-rotor motor principle, with the rotor turning around the stator within. Advantages of the ebm-papst external-rotor principle are: – Space saving design due to integrated bearings and direct installation inside the impeller – lower load and more precise balancing of the bearing due to the fixed connection of all rotating elements – Prolonged service life due to the motor-impeller unit placed right within the air flow The ebm-papst motors achieve very good results in efficiency and acoustic behaviour when used in EC technology. Features AC motors Shaded-pole motor Single-phase capacitor motor 1~ AC voltage connector Yes Yes 3~ AC voltage connector No No DC voltage connector No No EC motors 3-phase motor Single-core motor 3-core motor Yes Yes Yes No Yes No Yes Yes Electronics (see p. 598) Electronics (see p. 598) Limited use (Steinmetz circuit) Design of circuit diagram - Stator - Steinmetz circuit Rotor principle Squirrel cage Squirrel cage Squirrel cage Magnetic rotor Magnetic rotor Efficiency Low Medium Good Excellent Excellent Continuous speed setting integrated No No No Yes Yes Medium Good Excellent Medium Excellent Noise behaviour 590 General information AC centrifugal, backward AC centrifugal, forward AC motors (induction motors) are based in their function on the principle Shaded-pole motor of the asynchronous rotation of the stator rotating field and rotor. Each pole of the motor is divided electro-magnetically into a main EC centrifugal, backward AC motors and auxiliary pole (split) via a cage winding in order to generate a Torque curves of the motor types starting torque. symmetrical external or internal rotor designs. 2 EC centrifugal, backward for clean rooms [Ncm] At ebm-papst, shaded-pole motors are available as 2 or 4-pole 1 3 MK 4 EC centrifugal, forward M Sa 5 M St Advantages: – Extremely robust motor design due to cast squirrel cage rotor and stable bearing system – Cost-efficient motor 5 – System characteristic MSt – Starting torque MSa – Saddle torque MK – Breakdown torque – Extremely easy to connect EC-SYSTEMS Key: 1 – EC motor 2 – 3-phase motor 3 – Single-phase motor 4 – Shaded-pole motor – Long service life Start-up current Accessories The start-up current of our AC motors is maximally 4x higher 591 Contacts Technology than the nominal current given. Single-phase capacitor motor 3-phase motor Two cores (main winding MW and auxiliary winding AW) generate the The three motor cores are offset by 120° and generate a circular rotating rotating field of the single-phase capacitor motor via a capacitor field when connected to the 3-phase mains. connected in series to form an auxiliary winding. c ≈ 70 µF/kW (230 VAC ∆) Star Delta Steinmetz circuit Advantages: Advantages: – Extremely robust motor design due to cast squirrel cage rotor and stable bearing system – Extremely robust motor design due to cast squirrel cage rotor and stable bearing system – Very good vibration and noise behaviour – Diverse options for setting speed – Efficiency between 40 % and 80 % (depending on the motor size) – Efficiency between 30 % and 75 % (depending on motor size) – Long service life – Long service life – Good vibration and noise behaviour [Ncm] Torque curves of 3-phase motors 1 3 2 Key: 1 – Delta 2 – Star 592 3 – Steinmetz circuit General information AC centrifugal, backward AC centrifugal, forward EC motors Single-core motor EC centrifugal, backward EC motors are based in their function on the principle of the synchronous rotation of stator rotating field and rotor. Electronics [Ncm] Torque curves of the motor types EC centrifugal, backward for clean rooms 2 1 3 Advantages: – Integrated speed setting – Efficiency between 50 % and 80 % (depending on the motor size) 4 M St EC centrifugal, forward – Long service life M Sa 5 3-core motor EC-SYSTEMS Electronics Accessories 5 – System characteristic MSt – Starting torque MSa – Saddle torque MK – Breakdown torque Advantages: – Integrated speed setting – Good efficiency between 60 % and 90 % (depending on the motor size) – Long service life – Very good vibration and noise behaviour even in controlled operation – Can be used as drive motor Technology Key: 1 – EC motor 2 – 3-phase motor 3 – Single-phase motor 4 – Shaded-pole motor 593 Contacts MK Control technology Open and closed loop control using ebm-papst technology Depending on the field of application, fan speed has to be adjusted. In AC technology, the speed setting option can result in an increase in installation expenditure and, typically, a less favourable noise performance and an increase in power input. Here, ebm-papst EC technology is a more eco-friendly and cost-efficient alternative. The EC motor with integrated commutation electronics offers high efficiency across the entire speed range and optimal acoustic performance at minimal installation expenditure. Speed stepping Phase-angle control Phase-angle control with sine filter Frequency inverter Frequency inverter with sine filter integrated integrated with switch power supply external EC commutating electronics Transformer AC Series resistance Features Installation + – + – – – – ++ – – Noise behaviour + ++ – –– – – + ++ + + Power input –– – – – – + + ++ + + Service life + + – – + – + + + + + = positive + + = very positive Power input of controlled motors [dBA] [W] Acoustic performance of controlled motors – = negative – – = very negative 70 1500 60 50 1000 40 500 30 0 1000 2000 2000 4000 3000 4000 6000 5000 8000 Key: ebm-papst EC controls Frequency inverter with sine filter Phase-angle control without sine filter Phase-angle control with sine filter Transformer 594 6000 [CFM] 10000 [m³/h] 0 1000 2000 2000 4000 3000 4000 6000 5000 8000 Key: ebm-papst EC controls Frequency inverter with sine filter Phase-angle control without sine filter Phase-angle control with sine filter Transformer 6000 [CFM] 10000 [m³/h] General information AC centrifugal, backward AC centrifugal, forward Speed setting helps to optimise power input When selecting a voltage controller, note that the nominal current in the and the flow noise as requested. partial load range can be up to 20 % (depending on the controller) above EC centrifugal, backward Speed setting with AC motors the specified maximum current. Series resistance AW R1 0 – Speed setting via change in motor voltage ASM 1~ – Cost-efficient R2 1 2 L1 EC centrifugal, backward for clean rooms – Fixed speed steps C MW – Small capacities 3 Note: Capacitors or chokes reduce the loss capacity. N PE L1 4 Tr – Fixed speed steps AW 3 EC centrifugal, forward Transformer C 2 – Speed setting via change in motor voltage ASM 1~ 1 MW N EC-SYSTEMS PE Phase-angle control – Continuous speed setting C AW – Speed setting via change in motor voltage ASM 1~ – Cost-efficient – Acoustic performance and warming has to be reviewed Accessories in the application N PE Frequency inverter with sine filter T1 T3 T5 – Speed setting via change in frequency of rotating field + L3 U U V V W T2 T4 T6 W – High efficiency Technology L1 L2 – Continuous speed setting ASM 3~ Note: An all-pole sine filter (phase-phase and phase-earth) has to be used. PE 595 Contacts L1 MW Tr Electrical connections AC Fans, 1 speed (3~ 230 VAC power line) Fans (1~ 230 VAC power line) A1) Single-phase capacitor motor N PE L C U2 Z U1 U1 = blue U2 = black Z = brown = green/ yellow TOP with connection for external TOP N PE C TOP U2 Z U1 U1 = blue U2 = black Z = brown = green/ yellow A2b) Single-phase capacitor motor with connection for external TOP C U1 Z U2 L N PE Fans with terminal box 596 Shaded pole motor C1) Delta connection (3~ 230 VAC power system) L PE N without TOP L N = blue = brown = green/ yellow L1 PE L2 U1 V1 U2 V2 U1 U2 V1 V2 W1 W2 L3 W1 W2 TOP A2a) Single-phase capacitor motor L B) with TOP wired internally with TOP wired internally TOP TOP U1 = blue U2 = black Z = brown = green/ yellow = = = = = = = black green blue white brown yellow green/ yellow D1) Delta connection (3~ 230 VAC power line) with TOP L1 PE L2 U1 V1 U2 V2 L3 W1 W2 TOP U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow Direction of rotation is reversed by swapping two line phases. General information AC centrifugal, backward AC centrifugal, forward C2) Star connection (3~ 400 VAC power system) E1) Delta connection (high speed) U1 V1 W1 U2 V2 W2 = = = = = = = black green blue white brown yellow green/ yellow D2) Star connection (3~ 400 VAC power line) with TOP PE L1 L1 PE L2 U1 V1 U2 V2 U1 U2 V1 V2 W1 W2 L3 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow F1a) Delta connection (high speed) U1 V1 W1 U2 V2 W2 L3 TOP U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow Direction of rotation is reversed by swapping two line phases. L1 PE V1 U2 V2 L2 U1 U2 V1 V2 W1 W2 L3 U1 V1 W1 U2 V2 W2 = = = = = = = black green blue white brown yellow green/ yellow = = = = = = = black green blue white brown yellow green/ yellow = = = = = = = black green blue white brown yellow green/ yellow with TOP L2 U1 L1 F2a) Star connection (low speed) with TOP L2 PE EC centrifugal, backward for clean rooms U1 U2 V1 V2 W1 W2 L3 EC centrifugal, forward L2 L3 TOP W1 W2 U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow F1b) Delta connection (high speed) L2 U1 V1 W1 U2 V2 W2 L3 TOP U1 U2 V1 V2 W1 W2 with TOP U1 V1 W1 W2 U2 V2 TOP TOP Fans with terminal box L1 F2b) Star connection (low speed) with TOP L1 L2 L3 PE EC-SYSTEMS L1 without TOP PE U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow U1 V1 W1 W2 U2 V2 TOP TOP L1 L2 L3 Fans with terminal box PE U1 U2 V1 V2 W1 W2 Accessories PE E2) Star connection (low speed) without TOP Technology without TOP EC centrifugal, backward Fans, 2 speeds via ∆/Y-switch (3~ 400 VAC power line) Direction of rotation is reversed by swapping two line phases. 597 Contacts Fans, 1 speed (3~ 400 VAC power line) Speed setting with EC motors The speed of EC motors is set via commutation electronics. Via electronic circuits and depending on the rotor position, this commutation switches the motor currents on and off. Principle of AC-fed commutation electronics Interface Control unit Principle of DC-fed commutation electronics Power unit Interface Control unit Power unit EMC filter 0-10 VDC 0-10 VDC PWM PWM DC/DC transformer EMC filter Commutations unit Rectifier Feedback Commutations unit Feedback Link electrolytic capacitor Inverter stage CAN LON Drive CAN LON Inverter stage Drive RS485 RS485 (with electrically isolated interface) Integrated commutation electronics – Compact unit – Easy to install AC – Low installation expenditure – Can be operated all over the world Note: Motors with 12-72 VDC supply voltage have to be fed via electrically isolated supply unit. DC Integrated commutation electronics with switch power supply – Protective extra-low voltage 24 / 48 VDC AC Note: Switch power supply is not included but has to be ordered as accessory. 598 DC General information AC centrifugal, backward – minimal extra costs for additional functions (open / closed loop control) – Optional BUS interface EC centrifugal, backward AC centrifugal, forward – Low-noise operation across the entire speed range The motor restarts automatically after the following failures have EC centrifugal, backward for clean rooms – Speed setting via linear set value (0-10 VDC) or PWM signal recognised by the electronics, and the motor is switched off. been diagnosed: – Line failure – Phase failure – Line under-voltage – DC link voltage too high or too low – Locked rotor With the following types of failures, there is no automatic restart. EC centrifugal, forward – High efficiency throughout the entire speed range With AC-fed EC motors, certain faults in modes of operation are Here, hardware or software reset is required: – Motor temperature too high – Temperature of cooling element or ambient temperature of electronics too high – Hall failure EC-SYSTEMS – Integrated EMC filter recognised by the electronics, and the motor is automatically restarted. Hardware reset Switching off the fan and restarting it after one minute results in hardware reset. Software reset Software reset is via ebmBUS and LISA software, hand-held control Accessories – Open and closed loop control as well as monitoring of the motor With DC-fed EC motors, certain faults in modes of operation are terminal, or PDA with Fan Control Software. Technology – Input for analogue and digital signals Types of alarms and reactions with EC motors 599 Contacts Typical features of the ebm-papst commutation electronics: Electrical connections EC G) EC motors (nominal voltage 24 / 48 VDC) Notes on various control possibilities and their applications Maximum ripple ±3.5% red 33 K 4.7 K Lin/PWM control input 0-10 VDC / PWM yellow Counter Controller U PWM white 10 K 12 V Tach output pulses per revolution Isink max. 10 mA 680 Alarm Speed display 12 V 47 V Temperature control module Speed setting Speed setting with potentiometer PWM 1 - 10 kHz 50002-1-0174 50003-1-0174 Full speed GND blue Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 1.4 V start up at > 1.4 V Customer circuit Connection Fan + GND Tach 0-10 V PWM Line 1 red blue white yellow Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % 1 Tach GND blue GND white 2 pulses / revolution (M1G045 / M1G055) 0-10 V / PWM yellow 600 Tach output: 3 pulses / revolution (M1G074/M3G084) Control input (Impedance 100 k) General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward H1) EC motors (size 055, line-fed) Notes on various control possibilities and their applications Umin = 15 V L brown N blue Mains 50/60 Hz + - EC centrifugal, backward for clean rooms Imax = 10 mA PE green/yellow + Voltage output +10 V max. 1.1 mA U - 10 K red 12 V Lin/PWM control input 0-10 VDC / PWM Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 start up at > 1.4 V Counter Controller white 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 Alarm start up at > 1.4 V Speed display Customer circuit Isink max. 10 mA 680 47 V Connection Fan N PE +10 V 0-10 V PWM GND Tach Line 2 L Line 1 EC-SYSTEMS Full speed brown blue green/yellow red yellow blue white Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L brown Mains 50/60 Hz, phase 2 +10 V N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Voltage output +10 V max. 1.1 mA Control input (Impedance 100 k) PE green/yel Protective earth GND blue GND Tach white Tach output: 1 pulse per revolution red Accessories PWM 1 - 10 kHz Speed setting with variable resistance 1 F Technology Speed setting GND blue Tach output 1 pulse per revolution EC centrifugal, forward yellow 601 Contacts PWM H2) EC motors (size 055, line-fed and constant air flow) Notes on various control possibilities and their applications Umin = 15 V Imax = 10 mA L brown N blue Mains 50/60 Hz + - PE green/yellow + Voltage output +10 V max. 1.1 mA U PWM - 10 K red Lin/PWM input for set value 0-10 VDC / PWM 12 V yellow Air flow setting PWM 1 - 10 kHz Air flow setting with variable resistance Max. air flow Air flow setting 1 V - 10 V 100% PWM -> Vmax 17% PWM -> Vmin < 15% PWM -> V= 0m3/h start up at > 1.4 V Counter GND blue Tach output 1 pulse per revolution Controller white 10 V -> Vmax 1.7 V -> Vmin < 1.5 V -> V= 0m3/h Alarm start up at > 1.4 V Speed display Customer circuit 1 F Isink max. 10 mA 680 47 V Connection N PE +10 V 0-10 V PWM GND Tach Line 2 L Line 1 Fan brown blue green/yellow red yellow blue white Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L brown Mains 50/60 Hz, phase 2 +10 V N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Voltage output +10 V max. 1.1 mA Input for set value (impedance 100 k) PE green/yel Protective earth GND blue GND Tach white Tach output: 1 pulse per revolution 602 red General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward J1) EC motors (size 074, line-fed) Notes on various control possibilities and their applications Umin = 15 V L black N blue Mains 50/60 Hz + - EC centrifugal, backward for clean rooms Imax = 10 mA PE green/yellow + Voltage output +10 V max. 1.1 mA U - 10 K red 12 V Lin/PWM control input 0-10 VDC / PWM Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 start up at > 1.4 V Counter Controller white 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 Alarm start up at > 1.4 V Speed display Customer circuit Isink max. 10 mA 680 47 V Connection Fan N PE +10 V 0-10 V PWM GND Tach Line 2 L Line 1 EC-SYSTEMS Full speed black blue green/yellow red yellow blue white Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L black Mains 50/60 Hz, phase 2 +10 V N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Voltage output +10 V max. 1.1 mA Control input (Impedance 100 k) PE green/yel Protective earth GND blue GND Tach white Tach output: 1 pulse per revolution red Accessories PWM 1 - 10 kHz Speed setting with variable resistance 1 F Technology Speed setting GND blue Tach output 1 pulse per revolution EC centrifugal, forward yellow 603 Contacts PWM J2) EC motors (size 074, line-fed and constant air flow) Notes on various control possibilities and their applications L black N blue Mains 50/60 Hz 10 K + - PE green/yellow + Voltage output +10 V max. 1.1 mA U PWM - 10 K red Lin/PWM input for set value 0-10 VDC / PWM 12 V yellow Speed setting PWM 1 - 10 kHz Air flow setting with variable resistance Max. air flow Air flow setting 1 V - 10 V Counter GND blue Tach output 1 pulse per revolution Controller white 100% PWM -> V=max approx. 17% PWM -> V=min < 15% PWM -> V=0 10 V -> V=max approx. 1.7 V -> V=min < 1.5 V -> V=0 Alarm start up at > 1.4 V start up at > 1.4 V Speed display Customer circuit 1 F Isink max. 10 mA 680 47 V Connection GND Tach green/yellow 0-10 V PWM blue +10 V N black Line 2 PE L Line 1 Fan red yellow blue white Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L black Mains 50/60 Hz, phase 2 +10 V N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Voltage output +10 V max. 1.1 mA Input for set value (impedance 100 k) PE green/yel Protective earth GND blue GND Tach white Tach output: 1 pulse per revolution 604 red General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward K1) EC motors (size 084, line-fed) Notes on various control possibilities and their applications Umin = 15 V Mains 50/60 Hz U - 10 K + - NC white1 COM white2 Voltage output red +10 V max. 1.1 mA + PWM L black N blue PE green/yellow 12 V EC centrifugal, backward for clean rooms Imax = 10 mA Alarm relay: Break for failure (2 A, 250 VAC, AC1) 1 F GND blue Speed setting with variable resistance Full speed Speed setting 1 V - 10 V 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 1.4 V Customer circuit Connection +10 V 0-10 V PWM GND green/yellow white1 COM blue Line 2 NC N black PE L Line 1 Fan white2 red yellow blue Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L black Mains 50/60 Hz, phase 2 +10 V N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Voltage output +10 V max. 1.1 mA Control input (Impedance 100 k) PE green/yel Protective earth GND GND NC white1 Alarm relay, break for failure COM white2 Alarm relay, COMMON red blue Accessories start up at > 1.4 V EC-SYSTEMS 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 Technology PWM 1 - 10 kHz 605 Contacts Speed setting EC centrifugal, forward Lin/PWM control input yellow 0-10 VDC / PWM K2) EC motors (size 084/112 with ebmBUS, mains-powered) Connector Connection Assignment / function KL1 606 0V +15 V RS A RS B KL2 L N PE KL1 Connector Connection Assignment / function PE Protective earth RS B RS485 interface for ebmBUS; RS B N Mains 50/60 Hz, neutral RS A RS485 interface for ebmBUS; RS A L Mains 50/60 Hz, phase +15 V Operation: +15 V (50 mA); Alarm: 0 V 0V Operation: 0 V; Alarm: +15 V (50 mA) KL2 General information AC centrifugal, backward AC centrifugal, forward Connector Connection Assignment / function Connector Connection Assignment / function PE PE Protective earth KL3 KL1 N Mains 50/60 Hz, neutral L Master output 0-10 V max. 3 mA GND Mains 50/60 Hz, phase GND 0-10 V / PWM Control / Actual value input (Impedance 100 k) NC Alarm relay, break for failure +10 V COM Alarm relay, COMMON (2A, 250 VAC, AC1) NO Alarm relay, make for failure Supply for external potentiometer, 10 VDC (+10 %) @ 10 mA +20 V Supply for external sensor, 4-20 mA Control / Actual value input 20 VDC (±20 %) @ 50 mA GND GND RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A EC centrifugal, forward 0-10 V / PWM Control / Actual value input PE L3 Connector Connection Assignment / function Connector Connection Assignment / function PE PE Protective earth KL3 KL1 L3 Mains; L3 L2 Mains; L2 GND 0-10 V / PWM Control / Actual value input (Impedance 100 k) L1 Mains; L1 +10 V NC Alarm relay, break for failure COM Alarm relay, COMMON (2A, 250 VAC, AC1) NO Alarm relay, make for failure Master output 0-10 V max. 3 mA GND Supply for external potentiometer, 10 VDC (+10 %) @ 10 mA +20 V Supply for external sensor, 4-20 mA Control / Actual value input 20 VDC (±20 %) @ 50 mA 0-10 V / PWM Control / Actual value input GND GND RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A Technology KL2 OUT Accessories L1 L2 KL1 NC COM NO OUT GND +10 V 0-10 V PWM +20 V KL2 4-20 mA GND 0-10 V PWM RS B RS A RS B RS A KL3 EC-SYSTEMS L2) EC motors (size 112, three-phase mains-powered) 607 Contacts KL2 OUT EC centrifugal, backward for clean rooms L N PE KL1 NC COM NO OUT GND +10 V 0-10 V PWM +20 V KL2 4-20 mA GND 0-10 V PWM RS B RS A RS B RS A KL3 EC centrifugal, backward L1) EC motors (size 112, single-phase mains-powered) M) EC motors (size 150, three-phase mains-powered) PE L3 L1 L2 KL1 NC COM NO OUT GND +10 V 0-10 V PWM +20 V KL2 4-20 mA GND 0-10 V PWM RS B RS A RS B RS A KL3 Connector Connection Assignment / function Connector Connection Assignment / function PE PE Protective earth KL3 KL1 L3 Mains; L3 L2 Mains; L2 GND 0-10 V / PWM Control / Actual value input (Impedance 100 k) L1 Mains; L1 +10 V NC Alarm relay, break for failure COM Alarm relay, COMMON (2A, 250 VAC, AC1) NO Alarm relay, make for failure KL2 OUT Master output 0-10 V max. 3 mA GND Supply for external potentiometer, 10 VDC (+10 %) @ 10 mA +20 V Supply for external sensor, 4-20 mA Control / Actual value input 20 VDC (±20 %) @ 50 mA 0-10 V / PWM Control / Actual value input 608 GND GND RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A Technology Accessories EC-SYSTEMS PE L3 L2 L1 NC COM Slave Mains 50/60 Hz EC centrifugal, forward PE L3 L2 L1 NC COM NO OUT GND 0-10 V PWM +10 V +20 V Master Mains 50/60 Hz EC centrifugal, backward for clean rooms EC centrifugal, backward Alarm relay 609 Contacts PE L3 L2 L1 NC COM NO OUT GND 0-10 V PWM +10 V +20 V 4-20 mA 0-10 V PWM GND RS B RS A RS B RS A Pressure sensor NO OUT GND 0-10 V PWM +10 V +20 V 4-20 mA 0-10 V PWM GND RS B RS A RS B RS A PC with interface converter (RS485) 4-20 mA 0-10 V PWM GND RS B RS A RS B RS A Connection diagram: Condensing pressure control with master-slave fans Mains 50/60 Hz Slave AC centrifugal, forward AC centrifugal, backward General information fan agent compact fan agent Distributors, agencies and subsidiaries motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 79 38 / 81-0 Fax +49 (0) 79 38 / 81-110 info1@de.ebmpapst.com Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 (0) 77 24 / 81-0 Fax +49 (0) 77 24 / 81-13 09 info2@de.ebmpapst.com Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 (0) 8 71 / 707-0 Fax +49 (0) 8 71 / 707-465 info3@de.ebmpapst.com www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com Contacts Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 (0) 30 / 94 41 49 62 Fax +49 (0) 30 / 94 41 49 63 Jens.Duchow@de.ebmpapst.com Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 (0) 29 25 / 80 04 07 Fax +49 (0) 29 25 / 80 04 08 Hans-Joachim.Pundt@de.ebmpapst.com Frankfurt Dipl.-Ing. Christian Kleffmann Dr. Hermann-Krause Straße 23 D-63452 Hanau Phone +49 (0) 61 81 / 18 98 12 Fax +49 (0) 61 81 / 18 98 13 Christian.Kleffmann@de.ebmpapst.com Halle Dipl.-Ing. (TU) Michael Hanning Lerchenweg 4 D-06120 Lieskau Phone +49 (0) 3 45 / 5 51 24 56 Fax +49 (0) 3 45 / 5 51 24 57 Michael.Hanning@de.ebmpapst.com Hamburg Ingenieurbüro Breuell GmbH Dirk Kahl Elektroingenieur Grützmühlenweg 40 D-22339 Hamburg Phone +49 (0) 40 / 53 80 92 10 Fax +49 (0) 40 / 53 80 92 84 Dirk.Kahl@de.ebmpapst.com Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 38 D-35075 Gladenbach Phone +49 (0) 64 62 / 40 71 10 Fax +49 (0) 64 62 / 40 71 11 Ralph.Brueck@de.ebmpapst.com 610 Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 (0) 26 57 / 16 96 Fax +49 (0) 26 57 / 16 76 Winfried.Schaefer@de.ebmpapst.com Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Steinbergweg 6 D-82285 Hattenhofen Phone +49 (0) 81 45 / 80 92 25 Fax +49 (0) 81 45 / 80 92 26 Jens.Peter@de.ebmpapst.com Nuremberg Friedrich Klein Adlerstraße 49/1 D-73540 Heubach Phone +49 (0) 71 73 / 49 83 Fax +49 (0) 71 73 / 80 53 Friedrich.Klein@de.ebmpapst.com Offenburg Dipl.-Ing (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 (0) 78 02 / 98 22 52 Fax +49 (0) 78 02 / 98 22 53 Ralf.Braun@de.ebmpapst.com Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Mühlhaldenweg 13 D-73207 Plochingen Phone +49 (0) 71 53 / 92 89 80 Fax +49 (0) 71 53 / 92 89 81 Rudi.Weinmann@de.ebmpapst.com Ulm Günter Wilhelm Allgäuer Straße 7 D-89269 Vöhringen Phone +49 (0) 73 06 / 92 46 08 Fax +49 (0) 73 06 / 92 46 48 Guenter.Wilhelm@de.ebmpapst.com Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 (0) 61 06 / 84 10 Fax +49 (0) 61 06 / 84 11 11 info@red-elektromechanik.de www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 (0) 40 / 53 80 92 20 Fax +49 (0) 40 / 53 80 92 84 info@breuell.de Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 (0) 81 04 / 8 97 0 Fax +49 (0) 81 04 / 8 97 90 info@schweiger-gmbh.de www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 (0) 40 / 53 80 92 20 Fax +49 (0) 40 / 53 80 92 84 ebm@breuell.de South HDS Ventilatoren Vertriebs GmbH Glaswiesenstraße 1 D-74677 Dörzbach Phone +49 (0) 79 37 / 80 29 68 Fax +49 (0) 79 37 / 80 25 78 info@hds-gmbh.net General information AC centrifugal, backward Croatia ebm-papst Industries Kft. Mátyás u. 1/A H-2220 Vecsés Phone +36 / 29 / 55 01 90 Fax +36 / 29 / 55 01 94 office@hu.ebmpapst.com www.ebmpapst.hu Cyprus MATERO LTD 37, St. Kyriakides Avenue P.O. Box 51744 CY-3080 Limassol Phone +357 / 25 / 87 00 30 Fax +357 / 25 / 38 13 66 matero@cytanet.com.cy www.matero.com.cy Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 / 9 / 88 70 22 0 Fax +358 / 9 / 88 70 22 13 mailbox@ebmpapst.fi www.ebmpapst.fi France ebm-papst SARL ZI Nord - rue A. Mohler BP 62 F-67212 Obernai-Cedex Phone +33 / 820 326 266 Fax +33 / 3 / 88 67 38 83 info@ebmpapst.fr www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 / 210 / 951 37 05 Fax +30 / 210 / 951 34 90 contact@helcoma.gr www.helcoma.gr EC centrifugal, backward for clean rooms Ireland ebm-papst Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 / 57 86 / 643 43 Fax +353 / 57 86 / 643 46 sales@ie.ebmpapst.com www.ebmpapst.ie EC centrifugal, forward Estonia ebm-papst Oy Eesti Filiaal Kadaka tee 3 EST-10621 Tallinn Phone +372 / 655 / 6978 Fax +372 / 655 / 6979 EC centrifugal, backward AC centrifugal, forward Bulgaria ebm-papst Romania S.R.L. Str. Tirnavei Nr. 20 RO-500327 Brasov Phone +40 / 268 / 312 805 Fax +40 / 268 / 312 805 dudasludovic@xnet.ro Iceland RJ Engineers Stangarhyl 1A IS-110 Reykjavik Phone +354 / 567 80 30 Fax +354 / 567 80 15 rj@rj.is www.rj.is Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 / 03 31 / 83 62 01 Fax +39 / 03 31 / 82 15 10 info@it.ebmpapst.com www.ebmpapst.it EC-SYSTEMS Belgium VIBO Benelux B. V. Sales office Belgium-Luxembourg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 / 16 / 39 62 00 Fax +32 / 16 / 39 62 20 info@vibobenelux.com www.vibobenelux.com Denmark Jenk A/S Vallensbækvej 21 DK-2605 Brøndby Phone +45 / 43 / 63 11 11 Fax +45 / 43 / 63 05 05 jenk@jenk.dk www.jenk.dk Macedonia ebm-papst Industries Kft. Mátyás u. 1/A H-2220 Vecsés Phone +36 / 29 / 55 01 90 Fax +36 / 29 / 55 01 94 office@hu.ebmpapst.com www.ebmpapst.hu Accessories Belarus ebm-papst Bel AgmbH Prospekt Nesavisimosti 11/2 Zimmer 325, 512 BY-220050 Minsk Phone +375 / 17 / 209 95 61 Fax +375 / 17 / 209 95 61 info@by.ebmpapst.com Hungary ebm-papst Industries Kft. Mátyás u. 1/A H-2220 Vecsés Phone +36 / 29 / 55 01 90 Fax +36 / 29 / 55 01 94 office@hu.ebmpapst.com www.ebmpapst.hu Netherlands VIBO Benelux B. V. Engelseweg 127 Postbus 230 NL-5705 AC Helmond Phone +31 / 4 92 / 50 29 00 Fax +31 / 4 92 / 50 29 50 verkoop@vibobenelux.com www.vibobenelux.com Technology Austria ebm-papst Motoren & Ventilatoren GmbH Westbahnstraße 5 A-4490 St. Florian Phone +43 / 72 24 / 66 01 10 Fax +43 / 72 24 / 66 01 120 info@at.ebmpapst.com www.ebmpapst.at Czech Republic / Slovakia ebm-papst CZ s.r.o. Krátká 379 CZ-66461 Rajhradice u Brna Phone +420 / 5 / 47 23 26 16 Fax +420 / 5 / 47 23 26 22 info@ebmpapst.cz www.ebmpapst.cz 611 Contacts Europe fan agent compact fan agent Distributors, agencies and subsidiaries motor specialist motor agent Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 / 22 / 76 33 40 Fax +47 / 22 / 61 91 73 mailbox@ziehl-ebm.no www.ziehl-ebm.no Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236Warszawa Phone +48 / 22 / 675 78 19 Fax +48 / 22 / 676 95 87 office@ebmpapst.pl www.ebmpapst.pl Portugal ebm-papst (Portugal), Lda Av. Marechal Gomes da Costa, 35 e Rua Conselheiro Emidio Navarro P-1800-255 Lisboa Phone +351 / 21 / 839 48 80 Fax +351 / 21 / 839 47 59 info@pt.ebmpapst.com Romania ebm-papst Romania S.R.L. Str. Tirnavei Nr. 20 RO-500327 Brasov Phone +40 / 268 / 312 805 Fax +40 / 268 / 312 805 dudasludovic@xnet.ro Russia ebm-papst Ural GmbH Rosa Luxembourg Strasse 59 RU-620026 Jekaterinburg Phone +7 / 343 / 378 31 75 Fax +7 / 343 / 378 31 89 Konstantin.Molokov@ru.ebmpapst.com www.ebmpapst.ur.ru 612 ebm-papst Rus GmbH Nizhegorodskaya 32, str. 15 office 420 RU-109029 Moskau Phone +7 / 495 / 671 53 93 Fax +7 / 495 / 671 53 95 info@ebmpapst.ru www.ebmpapst.ru ebm-papst Rus Saint-Petersburg´s Filial Zastavskaya 7 RU-196084 Sankt-Petersburg Phone +7 / 812 / 449 96 07 Fax +7 / 812 / 449 96 07 spb@ru.ebmpapst.com Serbia & Montenegro ebm-papst Industries Kft. Mátyás u. 1/A H-2220 Vecsés Phone +36 / 29 / 55 01 90 Fax +36 / 29 / 55 01 94 office@hu.ebmpapst.com www.ebmpapst.hu Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 / 91 / 678 08 94 Fax +34 / 91 / 678 15 30 ventas@ebmpapst.es Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 / 8 / 761 94 00 Fax +46 / 8 / 36 23 06 info@ebmpapst.se www.ebmpapst.se Switzerland ebm-papst AG Rütisbergstraße 1 CH-8156 Oberhasli Phone +41 / 44 / 732 20 70 Fax +41 / 44 / 732 20 77 verkauf@ebmpapst.ch www.ebmpapst.ch Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 / 2 32 / 32 82 090 -91 Fax +90 / 2 32 / 32 80 270 akantel@akantel.com.tr www.akantel.com.tr Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 47 UA-03067 Kiev Phone +38 / 044 / 206 30 91 Fax +38 / 044 / 206 30 91 mail@ebmpapst.ua www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 / 12 45 / 46 85 55 Fax +44 / 12 45 / 46 63 36 sales@uk.ebmpapst.com www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane, East Ilsley GB-Berkshire RG20 7LG Phone +44 / 87 07 / 66 51 70 Fax +44 / 87 07 / 66 51 80 A&Dsales@uk.ebmpapst.com www.ebmpapst-ad.com General information AC centrifugal, backward AC centrifugal, forward ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 / 313 / 406 80 80 Fax +1 / 313 / 406 80 81 automotive@us.ebmpapst.com www.ebmpapst-automotive.us EC centrifugal, backward South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 / 11 / 794 34 34 Fax +27 / 11 / 794 50 20 info@za.ebmpapst.com www.ebmpapst.co.za EC centrifugal, backward for clean rooms Brasil ebm-papst Motores Ventiladores Ltda. Rua Francisco D´Amico, 155 Bairro Pirajussara BR-06785-290 Taboão da Serra-SP Phone +55 /11 / 41 38 50 90 Fax +55 /11 / 41 38 50 86 vendas@br.ebmpapst.com www.ebmpapst.com.br Africa EC centrifugal, forward Argentinia ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 / 11 46 57 61 35 Fax +54 / 11 46 57 20 92 ventas@ar.ebmpapst.com USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 / 860 / 674 15 15 Fax +1 / 860 / 674 85 36 sales@us.ebmpapst.com www.ebmpapst.us EC-SYSTEMS Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 / 905 / 420 / 35 33 Fax +1 / 905 / 420 / 37 72 sales@ca.ebmpapst.com www.ebmpapst.ca Technology Accessories Mexico ebm Industrial S.de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 / 55 / 50 91 44 44 Fax +52 / 55 / 50 91 44 43 sales@mx.ebmpapst.com www.ebmpapst.com.mx 613 Contacts America fan agent compact fan agent Distributors, agencies and subsidiaries motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 / 21 / 50 46 01 83 Fax +86 / 21 / 50 46 11 19 sales@cn.ebmpapst.com Hong Kong ebm-papst Ventilator (Shanghai) Co., Ltd. Hong Kong Representative Office Unit Nos. 13, 9/F, Technology Park 18 On Lai Street, Sha Tin, N.T. HK-Hong Kong P.R. of China Phone +852 / 21 45 / 86 78 Fax +852 / 21 45 / 76 78 chenghong@cn.ebmpapst.com India ebm NADI International Pvt Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 / 44 / 25 37 25 56 Fax +91 / 44 / 25 37 11 49 ebmnadi@md2.vsnl.net.in www.ebmnadi.com Indonesia ebm-papst Indonesia Representative Office Jalan Puri Kencana, Blok K7/3T RI-Jakarta 11610 Phone +62 / 21 / 582 / 31 18 Fax +62 / 21 / 582 / 31 17 sonny.sanjaya@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 / 3 / 910 03 00 Fax +972 / 3 / 579 66 79 polak@polak.co.il 614 Japan ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 / 45 / 470 / 57 51 Fax +81 / 45 / 470 / 57 52 info@jp.ebmpapst.com www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 / 2 / 36 62 / 13 24 Fax +82 / 2 / 36 62 / 13 26 info@kr.ebmpapst.com www.ebmpapst.co.kr Thailand ebm-papst Thailand Co. Ltd. Representative Office 99/349 Chaeng Wattana Road, Laksi Bangkok 10210, Thailand Phone +66 / 2 / 576 / 15 24-5 Fax +66 / 2 / 576 / 15 42 salesdept@th.ebmpapst.com United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 / 4 / 886 08 26 Fax +971 / 4 / 886 08 27 info@ae.ebmpapst.com Australia Australia ebm-papst Australia Pty Ltd. 2 Silverton Close AUS-Laverton North, Victoria, 3026 Phone +61 / 3 / 83 25 64 00 Fax +61 / 3 / 83 25 64 64 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst Australia Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 / 9 / 837 18 84 Fax +64 / 9 / 837 18 99 sales@ebmpapst.com.au www.ebmpapst.com.au Malaysia ebm-papst Malaysia Representative Office Block F1, 9A-4, Jalan PJU 1/42 Dataran Prima MAL-47301 Petaling Jaya Phone +60 / 3 / 78 06 54 40 Fax +60 / 3 / 78 06 54 41 john.bulder@my.ebmpapst.com Singapore ebm-papst SEA Pte. Ltd. 23 Ubi Road 4, #05-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 / 68 42 84 38 Fax +65 / 68 42 84 39 salesdept@sg.ebmpapst.com Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 / 7 / 557 42 68 Fax +886 / 7 / 557 27 88 eteco@ms22.hinet.net 615 fan agent compact fan agent Distributors, agencies and subsidiaries motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 / 21 / 50 46 01 83 Fax +86 / 21 / 50 46 11 19 sales@cn.ebmpapst.com Hong Kong ebm-papst Ventilator (Shanghai) Co., Ltd. Hong Kong Representative Office Unit Nos. 13, 9/F, Technology Park 18 On Lai Street, Sha Tin, N.T. HK-Hong Kong P.R. of China Phone +852 / 21 45 / 86 78 Fax +852 / 21 45 / 76 78 chenghong@cn.ebmpapst.com India ebm NADI International Pvt Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 / 44 / 25 37 25 56 Fax +91 / 44 / 25 37 11 49 ebmnadi@md2.vsnl.net.in www.ebmnadi.com Indonesia ebm-papst Indonesia Representative Office Jalan Puri Kencana, Blok K7/3T RI-Jakarta 11610 Phone +62 / 21 / 582 / 31 18 Fax +62 / 21 / 582 / 31 17 sonny.sanjaya@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 / 3 / 910 03 00 Fax +972 / 3 / 579 66 79 polak@polak.co.il 614 Japan ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 / 45 / 470 / 57 51 Fax +81 / 45 / 470 / 57 52 info@jp.ebmpapst.com www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 / 2 / 36 62 / 13 24 Fax +82 / 2 / 36 62 / 13 26 info@kr.ebmpapst.com www.ebmpapst.co.kr Thailand ebm-papst Thailand Co. Ltd. Representative Office 99/349 Chaeng Wattana Road, Laksi Bangkok 10210, Thailand Phone +66 / 2 / 576 / 15 24-5 Fax +66 / 2 / 576 / 15 42 salesdept@th.ebmpapst.com United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 / 4 / 886 08 26 Fax +971 / 4 / 886 08 27 info@ae.ebmpapst.com Australia Australia ebm-papst Australia Pty Ltd. 2 Silverton Close AUS-Laverton North, Victoria, 3026 Phone +61 / 3 / 83 25 64 00 Fax +61 / 3 / 83 25 64 64 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst Australia Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 / 9 / 837 18 84 Fax +64 / 9 / 837 18 99 sales@ebmpapst.com.au www.ebmpapst.com.au Malaysia ebm-papst Malaysia Representative Office Block F1, 9A-4, Jalan PJU 1/42 Dataran Prima MAL-47301 Petaling Jaya Phone +60 / 3 / 78 06 54 40 Fax +60 / 3 / 78 06 54 41 john.bulder@my.ebmpapst.com Singapore ebm-papst SEA Pte. Ltd. 23 Ubi Road 4, #05-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 / 68 42 84 38 Fax +65 / 68 42 84 39 salesdept@sg.ebmpapst.com Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 / 7 / 557 42 68 Fax +886 / 7 / 557 27 88 eteco@ms22.hinet.net 615 37777-7-8811 • KO-08/07-12’ Printed in Germany ebm-papst ebm-papst ebm-papst Mulfingen GmbH & Co. KG St.Georgen GmbH & Co. KG Landshut GmbH Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25 D-74673 Mulfingen D-78112 St.Georgen D-84030 Landshut Phone +49 (0) 7938 / 81-0 Phone +49 (0) 7724 / 81-0 Phone +49 (0) 871/ 707-0 Fax +49 (0) 7938 / 81-110 Fax +49 (0) 7724 / 81-1309 Fax +49 (0) 871 / 707-465 info1@de.ebmpapst.com info2@de.ebmpapst.com info3@de.ebmpapst.com Centrifugal fans and blowers version 07 Centrifugal fans and blowers www.ebmpapst.com The engineer’s choice version 07