Uploaded by petuskhi leo

blowers

advertisement
37777-7-8811 • KO-08/07-12’
Printed in Germany
ebm-papst
ebm-papst
ebm-papst
Mulfingen GmbH & Co. KG
St.Georgen GmbH & Co. KG
Landshut GmbH
Bachmühle 2
Hermann-Papst-Straße 1
Hofmark-Aich-Straße 25
D-74673 Mulfingen
D-78112 St.Georgen
D-84030 Landshut
Phone +49 (0) 7938 / 81-0
Phone +49 (0) 7724 / 81-0
Phone +49 (0) 871/ 707-0
Fax +49 (0) 7938 / 81-110
Fax +49 (0) 7724 / 81-1309
Fax +49 (0) 871 / 707-465
info1@de.ebmpapst.com
info2@de.ebmpapst.com
info3@de.ebmpapst.com
Centrifugal fans and blowers
version 07
Centrifugal fans and blowers
www.ebmpapst.com
The engineer’s choice
version 07
Centrifugal fans and blowers
4
– Company profile: ebm-papst
– Our key to success
General
information
General information
– How to use this catalogue
– How to order your ebm-papst product
Centrifugal fans from ebm-papst are available with forward or backward curved blades. The
AC centrifugal fans, backward curved
13
AC centrifugal fans and blowers, forward curved
91
Table of content
EC centrifugal fans, backward curved
221
EC centrifugal fans for clean rooms, backward curved
405
EC centrifugal fans and blowers, forward curved
421
– Centrifugal fans and blowers, forward curved and
single inlet
– Centrifugal blowers, forward curved and dual inlet
EC-SYSTEMS
517
– Options
– Switch power supplies
– External commutation electronics for rail technology
– Temperature sensor / control module
– Pressure control / selection module for 3 speeds
EC centrifugal,
backward
– Centrifugal blowers, forward curved and dual inlet
housing, while centrifugal fans are shipped without scrolls.
EC centrifugal, backward for clean rooms
single inlet
integrating the external rotor motor into the impeller. "Blowers" refers to devices with scroll
AC centrifugal,
forward
– Centrifugal fans and blowers, forward curved and
outstanding feature of the external rotor motors is their compact, flat design, which results from
Our complete range of blowers is available in AC and EC technology.
AC centrifugal,
backward
– How to find your ebm-papst product
EC centrifugal,
forward
– Interface converter / RS485 repeater
– RS485 terminal box / hand-held control terminal
– Speed setting
– LISA control software / fan control software
– HMS controller
Zubehör
549
EC-SYSTEMS
– Inlet nozzles
– Guard grilles
– Connection leads
– Capacitors
– Terminal boxes
– Air filters
Quiet movement
– Motor protection switch
Centrifugal fans with backward curved blades
Centrifugal fans and blowers with forward
– Star-delta switch / repair switch
are used primarily for intake suction and do not
curved blades always require a scroll housing.
require a scroll housing. They have high
Their characteristic features are a low noise
Technology
hydraulic efficiency.
level, relatively small air flow with a high
– Technical parameters & scope
increase in static pressure, and space-saving
– Impellers
application.
– Motors
571
Technology
More power
Accessories
– Speed setting
– Control technology
Distributors, agencies and subsidiaries
610
2
3
Contacts
is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG
Centrifugal fans and blowers
4
– Company profile: ebm-papst
– Our key to success
General
information
General information
– How to use this catalogue
– How to order your ebm-papst product
Centrifugal fans from ebm-papst are available with forward or backward curved blades. The
AC centrifugal fans, backward curved
13
AC centrifugal fans and blowers, forward curved
91
Table of content
EC centrifugal fans, backward curved
221
EC centrifugal fans for clean rooms, backward curved
405
EC centrifugal fans and blowers, forward curved
421
– Centrifugal fans and blowers, forward curved and
single inlet
– Centrifugal blowers, forward curved and dual inlet
EC-SYSTEMS
517
– Options
– Switch power supplies
– External commutation electronics for rail technology
– Temperature sensor / control module
– Pressure control / selection module for 3 speeds
EC centrifugal,
backward
– Centrifugal blowers, forward curved and dual inlet
housing, while centrifugal fans are shipped without scrolls.
EC centrifugal, backward for clean rooms
single inlet
integrating the external rotor motor into the impeller. "Blowers" refers to devices with scroll
AC centrifugal,
forward
– Centrifugal fans and blowers, forward curved and
outstanding feature of the external rotor motors is their compact, flat design, which results from
Our complete range of blowers is available in AC and EC technology.
AC centrifugal,
backward
– How to find your ebm-papst product
EC centrifugal,
forward
– Interface converter / RS485 repeater
– RS485 terminal box / hand-held control terminal
– Speed setting
– LISA control software / fan control software
– HMS controller
Zubehör
549
EC-SYSTEMS
– Inlet nozzles
– Guard grilles
– Connection leads
– Capacitors
– Terminal boxes
– Air filters
Quiet movement
– Motor protection switch
Centrifugal fans with backward curved blades
Centrifugal fans and blowers with forward
– Star-delta switch / repair switch
are used primarily for intake suction and do not
curved blades always require a scroll housing.
require a scroll housing. They have high
Their characteristic features are a low noise
Technology
hydraulic efficiency.
level, relatively small air flow with a high
– Technical parameters & scope
increase in static pressure, and space-saving
– Impellers
application.
– Motors
571
Technology
More power
Accessories
– Speed setting
– Control technology
Distributors, agencies and subsidiaries
610
2
3
Contacts
is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG
Company profile: ebm-papst
The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 9,800 people – in
Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and
our unique range of products based on a quality standard that surpasses every other have made us what we are:
world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving
to arrive at the perfect application solution for a wide variety of different industries is what determines our daily
work. Those who know us know the high standards we apply to our work and know our creed: to be as close
to our customers as possible and to simply be the best in terms of innovation and reliability.
Our headquarters in Mulfingen
4
General
information
AC centrifugal,
forward
AC centrifugal,
backward
clearance for serial production only after all the
Rooted in ebm, PAPST and mvl, the three leading innovators in the
desired characteristics have been determined to
development and production of motors and fans, ebm-papst has
be just right.
established itself as the world market leader. Now as ever, our legendary
Environmental care is another priority with
inventive spirit shines through in products that set standards in many
ebm-papst. This is why we have developed
segments of industry worldwide. We are proud to say that despite difficult
ou product line in EC technology, which makes
competition, our performance has always been exemplary and outstand-
for very low power consumption. Due to our
ing – in business, in our personal relationship with our customers, and of
manufacturing philosophy, there is absolute
course with respect to technology and engineering. For decades, we have
focus on environmental care in production,
contributed to the world of air technology and drive engineering with
recycling, waste and waste water disposal.
EC centrifugal, backward for clean rooms
Our history – Our drive
EC centrifugal,
backward
Left:
Our location in St. Georgen
Right:
Our location in Landshut
To maintain this advantage in skills and knowledge to get maximum
Global Domestic
quality and thus the highest degree of customer satisfaction, our
In order to be specialist for customised solutions
employees around the world put their passion and dedication to work
throughout the world, you need strong partners.
for you.
Global Domestic – i.e. being present all over the
EC centrifugal,
forward
small revolutions and large milestones.
individual country – is how we have established
Our catalogues just list the results of our incessant efforts in R&D:
ourselves in all important markets on this globe
products of highest quality and reliability. After all, it is our passion to
with our successful subsidiaries. And so you will
constantly try something new and improve what we have. In doing so,
always find ebm-papst close to home, speaking
we take advantage of the latest development methods and state-of-
your language, and knowing the demands of
the-art technology and invest quite heavily in R&D facilities. Best of all,
your markets. Besides, our worldwide produc-
though, we rely on excellently trained and skilled engineers and
tion alliance serves as a basis for competitive
technicians to be at your service in R&D and Sales & Distribution.
pricing. Our global services and logistic outlets,
EC-SYSTEMS
world and being a national company in each
Passionately involved in R&D
times and just-in-time delivery.
our five factories in Germany or one of our eleven international production
All our efforts are documented in a comprehen-
sites, our products always have the same high level of quality. This quality
sive quality management system, both for prod-
control is something you can definitely rely on! And this across all levels
ucts and services. Being certified as complying
of production and throughout all processes: consulting customers, devel-
with the tough requirements of the international
opment, material selection through to picking certified, choice suppliers
standards DIN EN ISO 9001, ISO/TS 16949-2
and on to the production of parts and final delivery. On top of this, our
and of standard DIN EN ISO 14001 is just one
products have to pass the most rigourous tests under all realistic operat-
seal of approval we have received for our
ing conditions: continuous stress test, salt spray test, vibration test, or
unceasing efforts to provide only the best
precision noise measuring, just to mention a few. And the product gets
quality products and services.
Technology
This is our promise without any compromise. Whether produced in one of
5
Contacts
Producing and safeguarding high-quality products and services
Accessories
i.e. IT networking, safeguard short reaction
Our key to success
Our innovations and technologies keep on turning into new industrial standards. This competitive capability can
only be maintained by seeing ventilation as a whole: the interrelationship between, and thus the system of, motor
engineering, aerodynamics, and electronics. These are our three core competencies, imminently connected and
linked in each of our products. And so we handle air intelligently and quietly and continue to set new standards in
drive technology. Our system solutions form the main part of our product range by now. And they will be our main
key to success.
Production
Winding machine
Motor engineering, aerodynamics, electronics
Finally, intelligence will become the decisive
Our drive is well known and famous with specialists: our external-rotor
factor on all markets in future. After all, only in
motor, which has made us world market leader – quietly, yet powerfully.
connection with electronics can drive and air
Being versatile as to integration, it is ideally suited to the most diverse
flow – as a system solution – have an optimal
applications. Based on this principle, we here at ebm-papst have devel-
effect in a product or application. Interfaces are
oped the widest range of fans and motor types in the world. And for hot
avoided, and thus potential faults and failures.
or aggressive blower mediums, the internal-rotor motor is the perfect
complement.
Setting new standards with EC technology
Wherever intelligent air handling is required,
Still, in drive engineering, certain applications simply require the internal-
where energy consumption needs to be reduced
rotor motor principle, and they are then realised with our motors specifi-
and performance has to be maximised, there
cally developed for such cases. Take, for instance, the steering support
our EC motors are your reliable answer. They do
motor in the automotive field developed as innovation in active steering.
not waste financial or natural resources.
Instead, they boost high efficiency, continuous
Be it axial or centrifugal fans, centrifugal blowers, compact fans or
controllability via analogue or digital inputs,
tangential blowers: we always design fan blades, impeller blades and
long and maintenance-free service life, and
ducted housings with the specific application in mind. We strive to
robustness.
minimise noise and to optimise efficiency. This is the challenge that
we have taken up and which we meet – working away powerfully
and quietly.
6
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Left: Endurance test room
Centre: Shaker
Right: Measurement station
EC centrifugal,
forward
Top: Betz manometer
Left: Precision noise measurement lab
– EC fan units for clean room technology.
As the electronics are integrated and the unit
is wired up completely and ready to plug in,
EC-SYSTEMS
there is no need for our customers to waste
time and money on laborious wiring work.
Without any problems, the ebm-papst EC technology allows you to realise
industry providing optimal selection of the
networked, bus-linked appliances, to integrate simple or complex controls
air-conditioning unit in the car and, combined
at low cost and to also realise time and again new, customised and
with booster blowers, individual air-condition-
complete solutions. Here, ebm-papst excels as competent development
ing of each and every passenger seat.
– EC gas blowers with commutation and
know-how in R & D and production also being well documented in a few
control electronics including a processor.
hundred national and international patents. And there is also our ability
They are developed in such a way as to
to listen intently, to pay good attention to our customers and their
make the blower premix the required amount
demands – in order to come up with new and pioneering ideas, such as:
of air with the gas. Aerodynamics with these
blowers are adjusted in such a way as to
Technology
make these blowers ideal for use in very
limited space at high back pressure.
7
Contacts
partner, with our experience of more than 25 years and our excellent
Accessories
– Sensitive EC sensor fans for the automotive
How to use this catalogue
The ebm-papst catalogue combines a technical and a product-specific section.
Technical section: General information on how to select and find ebm-papst products for your specific
application is found in the chapters "Selection" (p. 10) and "Technical parameters" (p. 572).
In case you require technical background information on ebm-papst product groups, simply turn to
the chapters "Impellers" (p. 576), "Motors" (p.590) and "Control technology" (p. 594).
Product-specific section: The product-specific section is organised according to product diameters,
lines, materials and/or design principles.
Headline
The headline indicates which technology (AC or EC), which design
AC centrifugal fans
(centrifugal, axial, etc.), and which line (e.g. S-Range) the product belongs
backward curved, 3-D, Ø 400
to. Impeller diameter or other features are also indicated.
– Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Number of blades: 6
Direction of rotation: Clockwise, seen on rotor
Type of protection: IP 54 (acc. to EN 60529)
Insulation class: "F"
Mounting position: Any
Condensate discharges: None
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
–
–
–
–
–
–
–
–
Part designation / Type
A – axial fan
S – axial fan with guard grille
W – axial fan with wall ring
Type
Motor
R4E 400
M4E 094-FA
F
A
R4E 400
M4E 094-HA
B
subject to alterations
1~
1~
1~
1~
Hz
rpm
W
A
µF/VDB
50
60
50
60
1355
1480
1370
1460
375
540
480
700
1.75
2.40
2.40
3.15
8.0 /400
8.0 /400
10.0 /450
10.0 /450
Capacitor
VAC
230
230
230
230
Max. current
draw (1)
Nominal data
Max. power
input (1)
1) Type
Speed/rpm (1)
part number:
Frequency
7
Curve
5 6
Nominal voltage
ebm-papst products and serves as
123 4
Electr. connection
This key designates and identifies all
Perm. amb. temp.
R 2 E 190 -AO 26 -05
°C
p. 596 f.
-40 to +60
-40 to +50
-40 to +80
-40 to +55
A2a)
A2a)
(1) Nominal data in operating point with maximum load
V – axial combination
R – centrifugal fan, single inlet
G – centrifugal blower, single inlet (with scroll housing)
M – motor
P – pumps
2
[Pa]
[in H O]
2,5
K – centrifugal combination
600
500
2,0
D – centrifugal blower, dual inlet (with scroll housing)
400
2) Number of poles (AC) / number of cores (EC)
2
2
300
1,0
2-, 4-, 6-, 8- and 12-pole (Z = 12) / 1- and 3-core
200
3) Type of motor
1
1
0,5
B
A
100
D – 3-phase motor
E – single-phase motor with capacitor
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
[CFM]
[m3/h]
60 Hz
G – EC motor
S – shaded-pole motor
56
Q – square shaded-pole motor
4) Impeller diameter in mm
5) Key for mechanical design
6) Key for electrical design
7) Key for mechanical variants
8
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1350
370
1.75
64
A
2
1380
331
1.58
65
B
1
1370
469
2.37
66
B
2
1390
430
2.17
68
Curves
1,5
B – centrifugal fan, dual inlet
What a product page is made up of (reduced scale - 50%)
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
Inlet nozzle
(long)
e
g
141.0 172.0 128.0
50.0
90.0
54476-2-4013
164.0 193.0 148.0
70.0 113.0
54476-2-4013
66
c ±1
22
d ±1
5
EC-SYSTEMS
Ø 370
Ø 257
EC centrifugal,
backward
Free-blowing or at minimal backpressure
AC products (from motor size 094) and EC products (AC-fed):
In operating point at maximum load
60
All drawings represent the design principle and are not to scale.
Dimensions are either given in the product drawing or, with varying
dimensions, in the table of dimensions given above the drawing.
Accessories
g
Depth of screw
max. 12 mm
b
Mounting dimensions
Ø
Technology
Ø7
Ø
5
11
55
0
10
57
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Indication of relevant accessories and additional information
The pages indicated at the bottom refer to the accessories, e.g. inlet
nozzles, guard grilles, wall rings, etc. for this particular product,
28
Contacts
Ø404
Ø 124
Ø268
0
Ø 100 -0,4
,3
M6
45˚
2
Brass lead tips
AC products (up to motor size 074) and EC products (DC-fed):
Graphic rendition of products
±0
e
Nominal data
11
50
90
5
and options.
EC-SYSTEMS
8.8
d
protection class, capacitor, product conforming to standards, approvals
Accessories
R4E 400-AP17 -06
c
EMC, leakage current, motor protection, electrical connection, cable exit,
as well as additional information (e. g. the connection diagram).
Electr. connections
p. 596 f.
Technology
7.1
b
discharge holes, mode of operation, design, bearing, technical equipment,
Curves and operating points
The diagram gives air performance curves pertaining to the product.
Refer to the operating point table to the right for information on speed,
power consumption, current draw, sound level or sound pressure level
and overall efficiency of the impeller.
9
Contacts
R4E 400-AR05 -06
Dimensions
EC centrifugal, backward for clean rooms
kg
system of protection, insulation class, mounting position, condensate
EC centrifugal,
forward
Mass of
centrifugal fan
Centrifugal fan
material, number of blades, direction of air flow, direction of rotation,
EC centrifugal, backward for clean rooms
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
AC centrifugal,
forward
–
–
–
–
Depending on the product, information is provided here on the following:
EC centrifugal,
forward
General
information
Product description
How to select your ebm-papst product
Solutions for ventilation offered by ebm-papst
In the field of ventilation, ebm-papst offers the perfect solution for a vast number of applications. Depending on motor,
impeller and control technology, there is almost no limit to the number of possible combinations, thus making sure you can
find the best solution for your application.
Criteria for selection
When selecting a fan for a specific application, these parameters play an
important role:
– Air flow with given back pressure
– Voltage supply, divided into DC and AC voltage (1~, 3~)
– Noise generation
– Efficiency
– Available mounting space
Selecting a fan
The following diagram shows the range of characteristic curves for the
most important fan designs and serves as a helpful tool in preselecting
a design on the basis of air flow and back pressure.
[Pa]
Characteristic curves of the various designs
axial fans
centrifugal fans, backward curved
centrifugal blowers, single inlet
centrifugal blowers, dual inlet
diagonal fans
1200
1000
800
600
400
200
200
10
500
1000
2000
5000
10000
20000
50000
[m³/h]
General
information
AC centrifugal,
forward
AC centrifugal,
backward
How to order your ebm-papst product
Have you found the suitable ebm-papst product and would like to order it now?
In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone.
Checklist
EC centrifugal,
backward
Don't know exactly which ebm-papst product you need to order?
In this case, simply contact your nearest ebm-papst sales office by
E-mail, fax or phone. Our specialists in ventilation and drive technology
– Part designation / type
are always there to help you find the best solution for your specific
– Quantity needed
application.
– Field of application
– Impeller diameter
make sure your ebm-papst contact has all the necessary information to
– Air flow
handle your enquiry as efficiently and quickly as possible.
– Back pressure
EC centrifugal, backward for clean rooms
– Ambient conditions (humidity, temperature, climate)
Using the questions provided in the checklist here as a guideline, you can
– Voltage supply
How your ebm-papst product is delivered
EC centrifugal,
forward
In our order confirmation, you will find information on when, how and
where to the delivery will be made.
We deliver:
– Ex works (excluding packaging)
– Via freight carrier (we also use postal services for shipments
EC-SYSTEMS
up to 30 kg)
All the other details such as packaging, freight, insurance and customs
duty will be settled with your ebm-papst contact prior to the time we
issue our order confirmation.
Accessories
For your nearest sales office, please turn to page 610.
Is there anything else you need to know about your
ebm-papst product?
In this case, simply contact your nearest ebm-papst sales office by
E-mail, fax or phone. We have the answer to your problem and are
always glad to be able to be of assistance.
make sure your ebm-papst contact has all the necessary information to
handle your enquiry as efficiently and quickly as possible.
11
Contacts
Technology
Using the questions provided in the checklist here as a guideline, you can
12
General
information
Ø 133 - Ø 355
14
AC centrifugal fans with sheet steel impeller
Ø 250 - Ø 280
36
AC centrifugal fans with aluminium impeller
Ø 310 - Ø 630
44
13
Contacts
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
AC centrifugal fans with plastic impeller
AC centrifugal,
forward
AC centrifugal,
backward
AC centrifugal fans backward curved
AC centrifugal fans
backward curved, Ø 133
Electr. connection
B
Perm. amb. temp.
M2E 052-BF
Sound pressure level
R2E 133
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 052-BF
Power input
R2E 133
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Partially cast in aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
240
280
290
345
2700
3200
2800
3300
25
28
24
27
0.11
0.13
0.11
0.13
1.0 /400
1.0 /400
1.0 /400
1.0 /400
53
56
56
60
-25 to +55
-25 to +65
-25 to +45
-25 to +60
A1)
A1)
subject to alterations
0,6
160
0,4
120
2
2
0,2
80
1
1
40
A
0
50
50
100
100
150
B
150
200
250
[CFM]
300
50 Hz
14
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2680
25
0.11
A
2
2680
25
0.11
B
1
2710
25
0.11
B
2
2700
26
0.12
2
[Pa]
200
0,8
240
[in H O]
Curves
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
EC centrifugal,
backward
Dimensions
Inlet nozzle
(long)
Centrifugal fan
kg
c
R2E 133-BH66 -07
0.7
73.0
09566-2-4013
R2E 133-BH66 -05
0.7
91.0
09566-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø58 ±0,2
13
53,6 ±0,5
EC centrifugal,
forward
c ±1
EC-SYSTEMS
27,5
Ø129
Ø87
Ø133
Ø72
Ø92,8
8
15
Brass lead tips
Accessories
M4
6
3
±2
41
2
60,6
Depth of screw
max. 5 mm
Technology
0
00
15
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
60
AC centrifugal fans
backward curved, Ø 133
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
60
280
320
2780
3200
36
34
0.25
0.21
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R2S 133
M2S 052-CA
1~ 230
1~ 230
A
—
—
55
58
-25 to +40
-25 to +60
B)
subject to alterations
2
[Pa]
200
0,8
240
[in H O]
Curves
160
0,6
A
0,4
120
2
0,2
80
1
40
0
50
50
100
100
150
150
200
250
[CFM]
300
50 Hz
16
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2720
38
0.27
A
2
2720
38
0.27
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Inlet nozzle
(long)
R2S 133-AE17 -05
0.9
09566-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
91±1
Ø58 ±0,2
EC-SYSTEMS
28,5
Ø129
Ø87
Ø133
Ø72
20
Ø92,8
8
EC centrifugal,
forward
13
58 ±0,5
Brass lead tips
M4
3
±2
41
60,6
2
Depth of screw
max. 5 mm
Technology
0
00
17
Inlet nozzle
p. 550
Electr. connections
p. 596 f.
Contacts
60
Accessories
6
AC centrifugal fans
backward curved, Ø 175
Electr. connection
B
Perm. amb. temp.
M2S 052-CA
Sound pressure level
R2S 175
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 052-CA
Power input
R2E 175
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: A IP 44, B IP 20
– Insulation class: A "F", B "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
490
570
440
430
2650
3100
2350
2300
50
51
53
51
0.25
0.23
0.33
0.29
1.5 /400
1.5 /400
—
—
63
68
61
60
-25 to +50
-25 to +80
-25 to +40
-25 to +55
A1)
B)
subject to alterations
[Pa]
[in H2O]
Curves
1,25
350
200
0,75
250
1,0
300
150
0,5
2
A
2
100
0,25
B
1
50
100
0
100
1
200
200
300
300
400
500
50 Hz
18
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2600
51
0.25
A
2
2530
53
0.26
B
1
2240
54
0.27
B
2
2120
56
0.28
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: A variable, B axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, B also GOST
EC centrifugal,
backward
Dimensions
kg
l
R2E 175-AR72 -05
0.9
68.5 450.0
09576-2-4013
R2S 175-AB56 -01
0.9
69.0 400.0
09576-2-4013
c ±1
61,5 ±0,5
EC centrifugal, backward for clean rooms
c
Inlet nozzle
(long)
Centrifugal fan
14
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø 58 ±0,2
EC-SYSTEMS
90˚
27,5
Ø 170
Ø125,5
Ø175
Ø72
Ø131
10
20
l
6
Accessories
M4
Depth of screw
max. 5 mm
2
Technology
42
62
19
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, Ø 190
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
M2E 068-BF
Power input
R2E 190
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
60
570
620
2500
2700
58
75
0.26
0.34
2.0 /400
2.0 /400
62
64
1~ 230
1~ 230
A
-25 to +50
-25 to +55
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
1,0
300
A
200
0,5
2
100
1
0
100
100
200
200
300
300
400
500
50 Hz
20
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2490
59
0.26
A
2
2410
61
0.27
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
kg
Inlet nozzle
(long)
R2E 190-AO26 -05
1.2
09576-2-4013
68,5±1
62,7±0,5
14
10
EC centrifugal,
forward
Ø 58 ±0,2
90˚
EC-SYSTEMS
27
Ø 170
Ø125,5
Ø190
15
Ø92
Ø131
Ø27±0,1
2
0
45
6
M4
Depth of screw
max. 5 mm
2
Accessories
44,6
62,8
Technology
Brass lead tips
21
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal fans
backward curved, Ø 220
Electr. connection
B
Perm. amb. temp.
M2E 068-CF
Sound pressure level
R2E 220
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 068-BF
Power input
R2E 220
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
860
900
885
990
2600
2700
2700
3050
85
90
85
115
0.38
0.40
0.38
0.51
3.0 /400
2.0 /400
2.5 /400
2.5 /400
73
74
72
75
-25 to +40
-25 to +40
-25 to +55
-25 to +55
A1)
A1)
subject to alterations
[Pa]
1,5
400
300
2
1,0
2
200
A
0,5
B
100
1
0
100
200
200
300
400
1
400
600
500
[CFM]
800
[m3/h]
50 Hz
22
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2390
95
0.42
A
2
2490
90
0.40
B
1
2650
96
0.43
B
2
2600
102
0.46
2
2,0
500
[in H O]
Curves
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
EC centrifugal,
backward
Dimensions
kg
d
e
R2E 220-AA40 -05
1.3
63.0
15.0
09609-2-4013
R2E 220-AB06 -05
1.5
73.0
25.0
09609-2-4013
71±1
d ±0,5
EC centrifugal, backward for clean rooms
Inlet nozzle
(long)
Centrifugal fan
21
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø 58 ±0,2
22
EC-SYSTEMS
90˚
27
Ø252
Ø155
Ø220
e
Ø 92
Ø159
Ø 27±0,1
2
0
45
6
Accessories
M4
Depth of screw
max. 5 mm
2
Technology
44
63
23
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, Ø 225
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
850
945
1050
1160
2650
2950
2700
3000
105
145
115
165
0.46
0.64
0.51
0.72
3.0 /450
3.0 /450
3.0 /450
3.0 /450
70
72
72
75
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R2E 225
M2E 068-DF
A
R2E 225
M2E 068-DF
B
1~
1~
1~
1~
-25 to +60
-25 to +65
-25 to +60
-25 to +30
A1)
A1)
subject to alterations
2
2,5
[Pa]
[in H O]
Curves
500
2,0
600
400
1,5
2
300
1,0
2
0,5
200
100
1
1
A
0
200
200
400
400
600
B
600
800
1000
[CFM]
1200
50 Hz
24
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2580
110
0.49
A
2
2560
113
0.50
B
1
2620
135
0.60
B
2
2670
124
0.55
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, B also GOST
EC centrifugal,
backward
Dimensions
kg
b
c
g
R2E 225-AT51 -05
2.1
63.3
69.0
38.0
96358-2-4013
R2E 225-AX52 -05
2.1
75.3
85.0
50.0
96358-2-4013
c ±1
83 ±0,5
EC centrifugal, backward for clean rooms
Inlet nozzle
(long)
Centrifugal fan
28
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø 58 ±0,2
25
EC-SYSTEMS
90˚
27
Ø223
Ø146
Ø225
35
Ø 92
Ø153
Ø 27±0,1
2
0
45
6
Depth of screw
max. 5 mm
2
Technology
b
Accessories
M4
g
25
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, Ø 225
Electr. connection
B
Perm. amb. temp.
M4E 068-CF
Sound pressure level
R4E 225
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 068-DF
Power input
R2E 225
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "F", B "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
1200
1340
655
765
2650
2950
1420
1660
135
200
40
37
0.60
0.88
0.20
0.18
4.0 /450
4.0 /450
1.5 /400
1.0 /400
69
71
59
61
-25 to +60
-25 to +60
-25 to +50
-25 to +80
A1)
A1)
subject to alterations
2
2,5
[Pa]
[in H O]
Curves
500
2,0
600
400
1,5
2
A
1,0
300
0,5
200
2
100
1
B
1
0
200
200
400
400
600
600
800
1000
[CFM]
1200
50 Hz
26
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2610
146
0.66
A
2
2650
138
0.61
B
1
1410
41
0.20
B
2
1400
43
0.21
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: A variable, B axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
EC centrifugal,
backward
Dimensions
kg
d
e
R2E 225-BD92 -09
2.1
83.0
35.0
96358-2-4013
R4E 225-AT01 -05
1.8
72.6
25.0
96358-2-4013
99 ±1
d ±0,5
EC centrifugal, backward for clean rooms
Inlet nozzle
(long)
Centrifugal fan
28
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø 58 ±0,2
25
EC-SYSTEMS
90˚
27
Ø223
Ø146
Ø225
e
Ø 92
Ø153
Ø 27±0,1
2
0
45
6
Accessories
M4
Depth of screw
max. 5 mm
2
Technology
62,6
89,3
27
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, Ø 250
R4E 250
M4E 068-CF
C
Electr. connection
B
Perm. amb. temp.
M2E 068-DF
Sound pressure level
R2E 250
1~
1~
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 068-EC
Power input
R2E 250
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "F", B C "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
230
230
50
60
50
60
50
60
1450
1490
1230
1335
810
930
2600
2700
2550
2750
1400
1600
155
215
115
160
43
43
0.70
0.95
0.51
0.71
0.20
0.20
5.0 /400
5.0 /400
4.0 /400
4.0 /400
1.5 /400
1.0 /400
75
76
71
72
61
64
-25 to +70
-25 to +45
-25 to +65
-25 to +45
-25 to +70
-25 to +80
A1)
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
P1
[W]
I
[A]
A
1
2400
152
0.69
A
2
2400
152
0.69
B
1
2350
137
0.61
B
2
2435
127
0.56
C
1
1385
46
0.21
C
2
1370
47
0.21
2,5
700
n
[rpm]
500
2,0
600
400
2
1,5
2
A
1,0
300
B
200
0,5
C
1
1
2
100
1
0
200
200
400
400
600
600
800
1000
[CFM]
1200
50 Hz
28
[m3/h]
60 Hz
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: A B variable, C axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, A C also GOST
EC centrifugal,
backward
Dimensions
kg
b
c
d
e
g
k
R2E 250-AS47 -26
3.1
84.3
99.0
97.5
42.0
56.0
27.0
96359-2-4013
R2E 250-AV65 -01
2.6
73.3
89.0
83.0
35.0
45.0
27.0
96359-2-4013
R4E 250-AH01 -05
2.2
84.3
99.0
72.6
25.0
56.0
29.0
96359-2-4013
c ±1
d ±0,5
31
EC centrifugal, backward for clean rooms
Inlet nozzle
(long)
Centrifugal fan
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Ø 58 ±0,2
28
EC-SYSTEMS
90˚
k
Ø 255
Ø 164,5
Ø 250
e
Ø 92
Ø 172
Ø 27±0,1
2
0
45
M4
g
2
Technology
b
Depth of screw
max. 5 mm
29
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
Accessories
6
AC centrifugal fans
backward curved, Ø 310
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M4E 068-EC
Power input
R4E 310
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
60
1830
2070
1400
1600
105
140
0.50
0.62
4.0 /400
4.0 /400
63
66
1~ 230
1~ 230
-25 to +55
-25 to +55
A1)
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,0
300
200
0,5
2
100
1
0
250
400
500
800
750
1200
1000
1600
1250
2000
50 Hz
30
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1380
118
0.56
A
2
1360
127
0.60
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Inlet nozzle
(long)
R4E 310-AT06 -01
3.5
97512-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Depth of screw
max. 5 mm
154±1
EC centrifugal,
forward
53
58 ±0,2
30
97,5 ±1
M4
27
Ø 300
Ø 192
Ø 92
Ø 203
Ø 318
Ø 27±0,1
42
EC-SYSTEMS
60
Brass lead tips
Accessories
6
85
450 ±20
2
Technology
101
132
31
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
2
AC centrifugal fans
backward curved, Ø 330
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M4E 074-DF
Power input
R4E 330
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
60
1760
2070
1450
1700
95
135
0.44
0.61
4.0 /400
4.0 /400
66
69
1~ 230
1~ 230
-25 to +60
-25 to +40
A1)
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,0
300
200
0,5
2
100
1
0
250
400
500
800
750
1200
1000
1600
1250
2000
50 Hz
32
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1420
112
0.52
A
2
1395
128
0.59
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
Inlet nozzle
(long)
R4E 330-AA06 -05
3.6
51357-2-4013
Depth of screw
max. 10 mm
144±1
60
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
90 ±0,2
5
54
104 ±1
M6
EC-SYSTEMS
37
Ø 350
Ø 224
Ø 75 ±0,1
2
Technology
80
127
33
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
Accessories
85
6
45
0±
20
Ø 102
Ø 237
Ø 360
28
35
AC centrifugal fans
backward curved, Ø 355
R6E 355
M6E 074-DF
C
Electr. connection
B
Perm. amb. temp.
M4E 074 -GA
Sound pressure level
R4E 355
1~
1~
1~
1~
1~
1~
Capacitor
A
Current draw
M4E 074-EI
Power input
R4E 355
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
230
230
50
60
50
60
50
60
2365
2740
2740
3190
1875
2050
1410
1630
1400
1630
910
1000
170
250
215
300
65
90
0.78
1.10
1.00
1.32
0.29
0.40
6.0 /400
6.0 /400
7.0 /400
7.0 /400
2.0 /400
2.0 /400
66
70
68
68
61
62
-25 to +55
-25 to +40
-25 to +50
-25 to +30
-25 to +70
-25 to +50
A1)
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
A
300
1,0
B
2
2
0,5
200
100
2
1
C
0
500
1000
1
1
1000
[CFM]
1500
2000
3000
50 Hz
34
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1390
190
0.82
A
2
1360
212
0.94
B
1
1390
228
1.06
B
2
1360
259
1.20
C
1
870
73
0.33
C
2
835
77
0.36
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
EC centrifugal,
backward
Dimensions
kg
c
d
e
g
R4E 355-AF05 -05
4.4
148.5 165.5 117.0
48.0 101.5
51357-2-4013
R4E 355-AG01 -05
4.5
173.0 190.0 129.0
60.0 126.0
51357-2-4013
R6E 355-AB16 -05
4.0
173.0 190.0 104.0
35.0 126.0
51357-2-4013
EC centrifugal, backward for clean rooms
b
Inlet nozzle
(long)
Centrifugal fan
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Depth of screw
max. 10 mm
c ±1
60
90 ±0,2
d ±1
M6
37
Ø 350
Ø 102
Ø 237
Ø 360
85
6
Accessories
45
0±
20
Ø 75 ±0,1
e
Ø 224
28
EC-SYSTEMS
5
54
2
g
Technology
b
35
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, Ø 250
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
M2E 068-EC
Power input
R2E 250
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
1780
2650
185
0.81
6.0 /400
72
1~ 230
A
-25 to +50
A1)
subject to alterations
1,5
400
2
A
1,0
300
200
0,5
1
100
0
250
400
500
800
750
1200
1000
1600
50 Hz
36
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2510
220
0.97
A
2
2615
190
0.84
2
[Pa]
[in H O]
Curves
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
Inlet nozzle
(long)
R2E 250-AW50 -05
3.1
96359-2-4013
141±1
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
58 ±0,2
31
97,5 ±0,5
28
Ø
EC-SYSTEMS
90˚
27
Ø 255
Ø164,5
±2
Ø 250
Ø 92
0
0
45
Ø172
42
Ø 27±0,1
Ø 222
2
6
60
2
M4
92
Technology
Depth of screw
max. 5 mm
37
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
Accessories
85
AC centrifugal fans
backward curved, Ø 270
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
60
2435
2760
2750
3100
280
430
1.23
1.88
10.0 /400
10.0 /400
77
80
Curve
Nominal voltage
– Material: Impeller: Sheet steel
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R2E 270
M2E 074-GA
1~ 230
1~ 230
A
-25 to +60
-25 to +60
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
700
500
2,0
600
A
400
1,5
2
1,0
300
200
0,5
1
100
0
250
500
600
750
1200
1000
1800
1250
1500
2400
50 Hz
38
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2665
245
1.08
A
2
2690
332
1.47
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Capacitor: FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
Inlet nozzle
(long)
R2E 270-AA01 -05
4.7
96360-2-4013
171±1
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
–
90 ±0,2
35
129 ±0,5
31
Ø
EC-SYSTEMS
90˚
37
Ø 280
Ø182,5
±2
Ø 270
0
0
45
Ø191
Ø 102
60
Ø 75 ±0,1
Ø 240
5
6
70
2
M6
102
Technology
Depth of screw
max. 10 mm
39
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
Accessories
85
AC centrifugal fans
backward curved, Ø 280
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
M2D 074-EI
Power input
R2D 280
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
50
50
1790
1460
2730
2200
210
160
0.37
0.25
3~ 400 ∆
3~ 400 Y
A
B
—
—
79
75
-25 to +80
-25 to +70
F1a)/F2a)
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
700
500
2,0
600
400
1,5
2
A
300
1,0
2
B
200
1
0,5
1
100
0
250
400
500
800
[CFM]
750
1200
1600
50 Hz
40
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2650
252
0.44
A
2
2550
302
0.53
B
1
1960
187
0.30
B
2
1975
185
0.29
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
kg
Inlet nozzle
(long)
R2D 280-AF10 -09
4.6
96360-2-4013
Depth of screw
max. 10 mm
125 ±1
35
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
90 ±0,2
5
M6
117 ±1
EC-SYSTEMS
37
Ø280
Ø182,5
Ø90 ±0,1
2
Technology
50
81,6
41
Inlet nozzle
p. 550
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
Accessories
85
6
45
0±
20
Ø102
Ø191
Ø281
31
48
AC centrifugal fans
backward curved, Ø 280
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
1~ 230
50
2110
2700
225
1.00
7.0 /400
76
-25 to +40
1~ 230
1~ 230
50
60
1435
1685
1420
1635
78
105
0.35
0.42
2.5 /450
2.5 /450
62
67
-25 to +40
-25 to +40
Curve
Nominal voltage
– Material: Impeller: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "F", B "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R2E 280
M2E 068-EC
R4E 280
M4E 068-DF
A
B
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
700
500
2,0
600
400
1,5
2
A
1,0
300
B
200
1
0,5
2
100
1
0
250
400
42
500
800
750
1200
1000
1600
1250
[CFM]
2000
[m3/h]
50 Hz
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2560
265
1.18
A
2
2390
312
1.38
B
1
1380
88
0.40
B
2
1340
99
0.44
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: A variable, B axial
Protection class: I
Capacitor: A FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
EC centrifugal,
backward
Dimensions
kg
b
d
e
g
R2E 280-AE52 -05
3.0
81.6
97.5
42.0
50.0
96360-2-4013
R4E 280-AD08 -05
2.8
111.4
82.5
35.0
80.0
96360-2-4013
125 ±1
d ±0,5
EC centrifugal, backward for clean rooms
Inlet nozzle
(long)
Centrifugal fan
35
EC centrifugal,
forward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
–
Ø 58 ±0,2
31
EC-SYSTEMS
90˚
27
Ø 280
Ø 182,5
Ø 92
Ø 191
e
Ø 280
Ø 27±0,1
2
0
45
6
Depth of screw
max. 5 mm
2
Technology
b
Accessories
M4
g
43
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Brass lead tips
AC centrifugal fans
backward curved, 3-D, Ø 310
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230/400
230/400
230/400
230/400
50
60
50
60
1710
1990
2120
2450
1430
1650
1400
1600
85
115
110
150
0.52/0.30
0.45/0.26
0.55/0.32
0.52/0.30
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 310 (1)
M4D 068-EC
A
R4D 310 (1)
M4D 068-EC
B
subject to alterations
3~
3~
3~
3~
—
—
—
—
62
66
60
63
2
[Pa]
[in H O]
1,5
400
350
1,0
300
200
2
2
0,5
150
1
100
1
A
50
0
250
400
500
800
750
1200
B
1000
1600
1250
2000
[CFM]
[m3/h]
50 Hz
44
C1)/C2)
C1)/C2)
(1) 230 VAC ∆ / 400 VAC Y
Curves (established with long inlet nozzle)
250
-25 to +75
-25 to +80
-25 to +65
-25 to +55
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1400
107
0.65/0.38
A
2
1400
113
0.69/0.40
B
1
1360
136
0.69/0.40
B
2
1350
141
0.71/0.41
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
EC centrifugal,
backward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Inlet nozzle
(long)
Inlet nozzle
(short)
70.0
31050-2-4013
31051-2-4013
139.0 154.0 101.0
31050-2-4013
31051-2-4013
Centrifugal fan
kg
b
c
R4D 310-AR18 -01
3.3
104.0 123.0
R4D 310-AS18 -01
3.4
g
EC centrifugal, backward for clean rooms
Dimensions
c ±1
EC centrifugal,
forward
Inlet nozzle (long)
48
Ø 58 ± 0,2
2
18
97,5 ±0,5
EC-SYSTEMS
90˚
27
Ø300
Ø208,1
Ø211
Ø92
Ø220
Ø318
Ø27± 0,1
55,5
42
6
450
Accessories
Brass lead tips
M4
2
g
Depth of screw
max. 5 mm
45
Inlet nozzle
p. 550
Guard grille
p. 553
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
b
AC centrifugal fans
backward curved, 3-D, Ø 310
Electr. connection
B
Perm. amb. temp.
M4E 068-EC
Sound pressure level
R4E 310
1~
1~
1~
1~
Capacitor
A
Current draw
M4E 068-EC
Power input
R4E 310
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "B", B "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
1690
1950
2130
2380
1410
1650
1370
1530
95
125
120
160
0.46
0.56
0.54
0.71
4.0 /400
4.0 /400
4.0 /400
4.0 /400
62
66
59
62
-25 to +70
-25 to +65
-25 to +85
-25 to +50
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
1,5
400
350
250
1,0
300
2 2
200
A
0,5
150
1
100
1
B
50
0
250
400
500
800
750
1200
1000
1600
1250
2000
50 Hz
46
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1370
114
0.55
A
2
1360
118
0.57
B
1
1310
140
0.63
B
2
1320
140
0.63
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
EC centrifugal,
backward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Inlet nozzle
(long)
Inlet nozzle
(short)
70.0
31050-2-4013
31051-2-4013
139.0 154.0 101.0
31050-2-4013
31051-2-4013
Centrifugal fan
kg
b
c
R4E 310-AR06 -01
3.3
104.0 123.0
R4E 310-AS06 -01
3.4
g
EC centrifugal, backward for clean rooms
Dimensions
c ±1
EC centrifugal,
forward
Inlet nozzle (long)
48
Ø 58 ± 0,2
2
18
97,5 ±0,5
EC-SYSTEMS
90˚
27
Ø300
Ø208,1
Ø211
Ø92
Ø220
Ø318
Ø27± 0,1
55,5
42
6
450
Accessories
Brass lead tips
M4
2
g
Depth of screw
max. 5 mm
47
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
b
AC centrifugal fans
backward curved, 3-D, Ø 310
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
1110
1320
1400
1640
950
1120
920
1070
45
55
48
60
0.21
0.25
0.22
0.27
1.5 /450
1.5 /450
1.5 /450
1.5 /450
51
55
50
53
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6E 310
M6E 068-EC
A
R6E 310
M6E 068-EC
B
1~
1~
1~
1~
-25 to +75
-25 to +80
-25 to +75
-25 to +75
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
0,5
150
2
2
0,25
100
1
50
1
A
0
250
200
400
500
600
800
B
750
1000
1200
[CFM]
1400
50 Hz
48
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
950
46
0.21
A
2
925
50
0.23
B
1
885
53
0.24
B
2
900
51
0.23
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
EC centrifugal,
backward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Inlet nozzle
(long)
Inlet nozzle
(short)
70.0
31050-2-4013
31051-2-4013
139.0 154.0 101.0
31050-2-4013
31051-2-4013
Centrifugal fan
kg
b
c
R6E 310-AI04 -01
3.3
104.0 123.0
R6E 310-AJ04 -01
3.4
g
EC centrifugal, backward for clean rooms
Dimensions
c ±1
EC centrifugal,
forward
Inlet nozzle (long)
48
Ø 58 ± 0,2
2
18
97,5 ±0,5
EC-SYSTEMS
90˚
27
Ø300
Ø208,1
Ø211
Ø92
Ø220
Ø318
Ø27± 0,1
55,5
42
6
450
Accessories
Brass lead tips
M4
2
g
Depth of screw
max. 5 mm
49
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
b
AC centrifugal fans
backward curved, 3-D, Ø 355
R4E 355
M4E 074-GA
C
Electr. connection
B
Perm. amb. temp.
M4E 074-EI
Sound pressure level
R4E 355
3~
3~
1~
1~
1~
Capacitor
A
Current draw
M4D 074-EI
Power input
R4D 355
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
400 Y
400 Y
230
230
230
50
60
50
60
50
2580
2930
2580
2940
3160
1400
1600
1400
1600
1420
170
235
180
260
245
0.52
0.50
0.80
1.14
1.12
—
—
6.0 /450
6.0 /450
8.0 /400
65
69
66
69
66
-25 to +70
-25 to +65
-25 to +60
-25 to +35
-25 to +50
D2)
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
500
1,5
1,0
2
2
C
200
0,5
B A
1
100
0
500
500
1000
1000
1500
1
1500
2000
2500
[CFM]
3000
50 Hz
50
[m3/h]
60 Hz
P1
[W]
I
[A]
A
1
1375
205
0.63
A
2
1360
227
0.70
B
1
1350
209
0.93
B
2
1330
229
1.02
C
1
1395
273
1.25
C
2
1375
295
1.35
400
300
n
[rpm]
General
information
B
C
TOP wired internally
AC centrifugal,
backward
Motor protection: A design with thermal overload protector,
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
R4D 355-AH11 -05
4.7
R4E 355-AK05 -05
R4E 355-AL02 -05
Dimensions
b
c
d
Inlet nozzle
(long)
Inlet nozzle
(short)
96.0
35560-2-4013
35561-2-4013
96.0
35560-2-4013
35561-2-4013
60.0 120.5
35560-2-4013
35561-2-4013
e
g
146.5 167.0 117.0
48.0
4.7
146.5 167.0 117.0
48.0
5.3
171.0 190.0 129.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
60
22
,5
37
Ø 240
Ø 236,4
Ø360
Ø250
Ø 102
Ø75 ±0,1
±2
0
85
6
Accessories
45
0
90 ±0,2
M6
70
e
Ø 350
d ±1
44
5
Depth of screw
max. 10 mm
EC-SYSTEMS
c ±1
EC centrifugal,
forward
Inlet nozzle (long)
2
Brass lead tips
g
51
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
b
AC centrifugal fans
backward curved, 3-D, Ø 355
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
230
230
230
230
50
60
50
60
1700
1890
1930
1940
910
1000
870
890
65
85
70
90
0.29
0.37
0.31
0.40
2.0 /400
2.0 /400
2.0 /400
2.0 /400
54
57
52
53
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6E 355
M6E 074-DF
A
R6E 355
M6E 074-DF
B
1~
1~
1~
1~
-25 to +90
-25 to +75
-25 to +85
-25 to +60
A1)
A1)
subject to alterations
[Pa]
0,6
160
A
0,4
120
2
80
2
0,2
B
1
1
40
0
250
400
500
800
750
1200
1000
1600
50 Hz
52
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
860
71
0.32
A
2
850
73
0.33
B
1
785
80
0.35
B
2
805
78
0.34
2
0,8
200
[in H O]
Curves (established with long inlet nozzle)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: GOST
EC centrifugal,
backward
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Inlet nozzle
(long)
Inlet nozzle
(short)
96.0
35560-2-4013
35561-2-4013
171.0 190.0 120.5
35560-2-4013
35561-2-4013
Centrifugal fan
kg
b
c
R6E 355-AD16 -05
3.5
146.5 167.0
R6E 355-AE16 -05
4.1
g
EC centrifugal, backward for clean rooms
Dimensions
60
22
37
Ø 350
Ø 240
Ø 236,4
Ø360
Ø250
Ø 102
Ø75 ±0,1
±2
0
Accessories
85
6
45
0
70
35
90 ±0,2
M6
,5
104 ±1
44
5
Depth of screw
max. 10 mm
EC-SYSTEMS
c ±1
EC centrifugal,
forward
Inlet nozzle (long)
2
Brass lead tips
g
53
Inlet nozzle
p. 550
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
b
AC centrifugal fans
backward curved, 3-D, Ø 400
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
°C
p. 596 f.
1~ 230
50
3150
1300
270
1.20
8.0 /400
68
-25 to +45
1~ 230
1~ 230
50
60
2225
2455
910
1000
117
160
0.52
0.70
3.0 /450
3.0 /450
62
64
-25 to +55
-25 to +40
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "F", B "B"
– Mounting position: A any, B shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: A none, B rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4E 400
M4E 074-EI
R6E 400
A
M6E 074-EI
B
A1)
A1)
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
300
1,0
2
A
200
B
0,5
2
100
1
1
0
500
500
1000
1000
1500
1500
2000
2500
[CFM]
3000
50 Hz
54
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1240
292
1.30
A
2
1250
287
1.27
B
1
880
125
0.56
B
2
880
125
0.56
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, B also GOST
kg
Inlet nozzle
(long)
R4E 400-AB23 -05
5.2
54476-2-4013
R6E 400-AA04 -05
5.2
54476-2-4013
66
22
117 ±1
37
Ø 370
Ø 257
Ø404
Ø268
Ø 102
±2
0
Accessories
85
6
45
0
Ø75 ±0,1
48
90 ±0,2
M6
50
90
5
Depth of screw
max. 10 mm
EC-SYSTEMS
162 ±1
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
2
Brass lead tips
91
55
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Technology
142
AC centrifugal fans
backward curved, 3-D, Ø 400
M4E 094-HA
B
subject to alterations
Electr. connection
R4E 400
1~
1~
1~
1~
Perm. amb. temp.
A
Capacitor
M4E 094-FA
Max. current
draw (1)
R4E 400
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
°C
p. 596 f.
230
230
230
230
50
60
50
60
1355
1480
1370
1460
375
540
480
700
1.75
2.40
2.40
3.15
8.0 /400
8.0 /400
10.0 /450
10.0 /450
-40 to +60
-40 to +50
-40 to +80
-40 to +55
2
[Pa]
[in H O]
2,5
2,0
600
400
2
1,5
2
1,0
300
200
1
1
0,5
B
A
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
56
A2a)
(1) Nominal data in operating point with maximum load
Curves
500
A2a)
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1350
370
1.75
64
A
2
1380
331
1.58
65
B
1
1370
469
2.37
66
B
2
1390
430
2.17
68
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
kg
R4E 400-AR05 -06
7.1
R4E 400-AP17 -06
8.8
b
c
EC centrifugal,
backward
d
Inlet nozzle
(long)
e
g
141.0 172.0 128.0
50.0
90.0
54476-2-4013
164.0 193.0 148.0
70.0 113.0
54476-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Dimensions
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
55
4x90˚
0
10
57
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, Ø 400
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
°C
p. 596 f.
400 ∆
400 Y
400 ∆
400 Y
50
50
60
60
1415
1235
1610
1220
515
385
750
515
1.41
0.70
1.44
0.93
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, riveted
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 400
M4D 094-HA
A
B
C
D
subject to alterations
3~
3~
3~
3~
—
—
—
—
-40 to +60
-40 to +80
-40 to +60
-40 to +40
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
Curves
2,0
600
500
1,5
400
C
2
2
300
A
1,0
B
D
200
1
0,5
1
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
58
F1a)/F2a)
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1415
490
1.40
63
A
2
1415
500
1.41
65
B
1
1240
380
0.67
70
B
2
1320
281
0.52
66
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
kg
Inlet nozzle
(long)
R4D 400-AD22 -06
8.7
54476-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
55
4x90˚
0
10
59
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, Ø 400
M6E 094-FA
B
subject to alterations
Electr. connection
R6E 400
1~
1~
1~
1~
Perm. amb. temp.
A
Capacitor
M4E 094-HA
Max. current
draw (1)
R4E 400
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, riveted
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
°C
p. 596 f.
230
230
230
230
50
60
50
60
1370
1500
895
990
480
695
155
220
2.40
3.18
0.68
0.97
10.0 /400
10.0 /450
5.0 /450
5.0 /450
-40 to +70
-40 to +55
-40 to +95
-40 to +85
2
[Pa]
[in H O]
2,0
600
A
1,5
400
2
1,0
300
B
200
1
0,5
2
100
1
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
60
A2a)
(1) Nominal data in operating point with maximum load
Curves
500
A2a)
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1380
464
2.36
68
A
2
1380
462
2.36
65
B
1
900
149
0.65
56
B
2
910
143
0.65
54
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
EC centrifugal,
backward
Dimensions
Inlet nozzle
(long)
kg
d
e
R4E 400-AN09 -06
8.7
148.0
70.0
54476-2-4013
R6E 400-AK06 -06
8.7
128.0
50.0
54476-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
55
4x90˚
0
10
61
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
1350
0.74 2.60/1.50
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 450 (2)
M4D 110-GF
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
-40 to +80
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
400
2
1,5
6
9
300
1,0
12
8
1
0,5
11
4
100
7
10
0
1000
1000
2000
2000
80/140 V
62
3000
100/180 V
3000
4000
130/230 V
5000
[CFM]
[m3/h]
230/400 V
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1370
0.65
2.35/1.35
75
A
2
1350
0.73
2.50/1.45
70
A
3
1380
0.61
2.25/1.30
76
A
4
1155
0.47
2.40/1.40
70
A
5
1115
0.51
2.60/1.50
65
A
6
1180
0.45
2.25/1.30
72
A
7
1055
0.37
2.45/1.40
68
A
8
955
0.38
2.60/1.50
61
A
9
1100
0.32
2.25/1.30
70
A
10
830
0.26
2.25/1.30
61
A
11
780
0.27
2.25/1.30
56
A
12
850
0.25
2.15/1.25
63
5
200
n
[rpm]
A
3
2,0
500
[in H O]
Curves
A
D1)/D2)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4D 450-AK01 -01
12.5
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63045-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
63
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 450
subject to alterations
Capacitor
Perm. amb. temp.
Electr. connection
M4E 110-GF
Max. current
draw (1)
R4E 450
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
50
1250
0.68
3.00
1~ 230
A
14.0 /400 -40 to +70
(1) Nominal data in operating point with maximum load
2
A
2,0
[Pa]
[in H O]
Curves
500
3
1,5
400
2
1,0
200
9
5
0,5
1
12
8
100
4
11
7
10
0
1000
1000
2000
2000
3000
105 V
3000
4000
130 V
5000
160 V
[CFM]
[m3/h]
230 V
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1300
0.65
2.80
74
A
2
1265
0.68
3.00
69
A
3
1320
0.62
2.68
75
A
4
970
0.43
2.80
65
A
5
900
0.43
2.90
60
A
6
1040
0.41
2.71
69
A
7
720
0.29
2.40
61
A
8
670
0.29
2.49
53
A
9
790
0.29
2.41
62
A
10
545
0.19
2.00
50
A
11
510
0.19
2.00
47
A
12
580
0.19
2.00
54
6
300
64
A2a)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4E 450-AK01 -01
12.5
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63045-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
65
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
930
0.29 1.30/0.75
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 450 (2)
M6D 110-EF
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
-40 to +85
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
2
1,0
250
[in H O]
Curves
A
3
0,75
200
6
2
150
0,5
100
12
8
1
0,25
11
4
7
50
10
0
500
1000
1000
80/140 V
66
1500
2000
2000
3000
100/180 V
2500
4000
130/230 V
[CFM]
[m3/h]
230/400 V
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
950
0.25
1.12/0.65
66
A
2
940
0.28
1.15/0.66
63
A
3
950
0.26
1.12/0.65
65
A
4
830
0.18
0.92/0.53
61
A
5
805
0.20
1.00/0.58
58
A
6
825
0.18
0.94/0.54
60
A
7
735
0.15
0.94/0.54
58
A
8
705
0.16
1.01/0.58
54
A
9
730
0.15
0.95/0.55
58
A
10
615
0.11
0.90/0.52
52
A
11
580
0.11
0.94/0.54
48
A
12
610
0.11
0.90/0.52
52
9
5
D1)/D2)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6D 450-AN01 -01
10.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63045-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
67
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
50
930
0.30
1.42
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6E 450
M6E 110-EF
1~ 230
A
subject to alterations
8.0 /450 -40 to +70
(1) Nominal data in operating point with maximum load
2
A
1,0
[Pa]
[in H O]
Curves
250
3
6
200
0,75
2
9
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
945
0.27
1.30
65
A
2
935
0.29
1.38
61
A
3
945
0.27
1.28
67
A
4
865
0.21
1.30
62
A
5
840
0.22
1.40
59
A
6
880
0.19
1.20
64
A
7
740
0.17
1.41
58
A
8
665
0.18
1.50
53
A
9
775
0.16
1.39
61
A
10
520
0.12
1.30
48
A
11
465
0.12
1.38
44
A
12
565
0.12
1.30
52
5
0,5
150
8
12
100
1
0,25
4
11
50
7
10
0
500
1000
1000
1500
2000
105 V
68
A2a)
2000
3000
130 V
2500
4000
160 V
[CFM]
[m3/h]
230 V
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6E 450-AN01 -01
10.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63045-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
69
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, Ø 450
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
°C
p. 596 f.
3~ 400 ∆
3~ 400 Y
1~ 230
50
50
50
1380
1130
1290
665
470
640
1.55
0.82
3.10
—
-40 to +50
—
-40 to +55
10.0 /400 -40 to +50
1~ 230
1~ 230
50
60
905
1010
320
425
1.56
1.86
10.0 /400 -40 to +40
10.0 /450 -40 to +55
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, riveted
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 450
M4D 094-HA
R4E 450
M4E 094-HA
R6E 450
A
B
C
M6E 094-HA
D
subject to alterations
2
[in H O]
2,0
[Pa]
A2a)
A2a)
(1) Nominal data in operating point with maximum load
Curves
500
F1a)/F2a)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1390
610
1.52
70
A
2
1380
650
1.53
69
B
1
1130
470
0.82
64
B
2
1260
350
0.65
68
C
1
1310
602
2.97
69
C
2
1310
596
2.92
68
D
1
910
305
1.50
61
D
2
905
310
1.53
58
A
C
2
2
2
1,5
400
B
300
1,0
D
1
2
1
1
0,5
200
1
100
0
500
1000
70
1000
1500
2000
2000
3000
2500
4000
[CFM]
[m3/h]
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
EC centrifugal,
backward
Dimensions
kg
c
g
R4D 450-AD22 -06
9.3
175.0 204.0 120.0
54478-2-4013
R4E 450-AB09 -06
9.3
175.0 204.0 120.0
54478-2-4013
R6E 450-AB06 -06
9.6
215.0 244.0 160.0
54478-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
b
Inlet nozzle
(long)
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
55
4x90˚
0
10
71
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 500
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
1375
1.43 5.20/3.00
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 500(2)
M4D 138-HF
A
subject to alterations
(1) Nominal data in operating point with maximum load
—
-40 to +80
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
A
2,5
700
600
2,0
2
1,5
400
6
300
5
1
1,0
9
8
200
4
0,5
12
7
11
100
10
0
1000
1000
2000
2000
3000
80/140 V
72
3000
4000
5000
100/180 V
4000
6000
7000
130/230 V
[CFM]
[m3/h]
230/400 V
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1380
1.36
4.99/2.88
81
A
2
1375
1.42
5.13/2.96
79
A
3
1375
1.43
5.20/3.00
77
A
4
1150
0.97
5.25/3.03
76
A
5
1125
1.00
5.42/3.13
74
A
6
1140
0.97
5.28/3.05
73
A
7
970
0.73
5.18/2.99
71
A
8
945
0.74
5.30/3.06
69
A
9
970
0.73
5.16/2.98
68
A
10
775
0.49
4.66/2.69
64
A
11
755
0.49
4.73/2.73
63
A
12
775
0.49
4.68/2.70
62
3
500
D1)/D2)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4D 500-AT03 -01
26.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63072-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 18 mm
73
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
Technology
Brass lead tips
AC centrifugal fans
backward curved, 3-D, Ø 500
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
910
0.48 1.90/1.10
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 500(2)
M6D 110-GF
A
subject to alterations
(1) Nominal data in operating point with maximum load
—
-40 to +80
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
2
1,0
250
[in H O]
Curves
A
3
2
0,75
200
5
9
0,5
1
8
100
12
4
11
0,25
7
50
10
0
1000
1000
2000
2000
80/140 V
74
3000
100/180 V
3000
4000
130/230 V
5000
[CFM]
[m3/h]
230/400 V
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
915
0.45
1.73/1.00
68
A
2
910
0.47
1.77/1.02
65
A
3
915
0.44
1.69/0.98
66
A
4
760
0.31
1.66/0.96
62
A
5
745
0.32
1.72/1.00
60
A
6
770
0.30
1.60/0.93
61
A
7
650
0.23
1.59/0.92
57
A
8
630
0.24
1.64/0.95
55
A
9
665
0.23
1.57/0.90
57
A
10
530
0.16
1.43/0.82
52
A
11
510
0.16
1.45/0.84
49
A
12
545
0.16
1.41/0.81
52
6
150
D1)/D2)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6D 500-AK03 -01
13.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63072-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
75
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 500
subject to alterations
Perm. amb. temp.
Electr. connection
A
Capacitor
M6E 110-GF
Max. current
draw (1)
R6E 500
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
50
910
0.51
2.34
1~ 230
12.0 /450 -40 to +60
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
Curves
A
300
3
1,00
250
0,75
2
200
0,50
100
4
0,25
9
8
7
12
11
10
0
1000
2000
2000
105 V
76
3000
4000
4000
6000
130 V
160 V
[CFM]
[m3/h]
230 V
P1
[kW]
I
[A]
LwA
[dB(A)]
1
915
0.49
2.24
70
A
2
910
0.51
2.33
67
A
3
915
0.48
2.22
68
A
4
720
0.37
2.55
62
A
5
690
0.38
2.64
60
A
6
730
0.37
2.50
61
A
7
515
0.27
2.35
52
A
8
485
0.27
2.37
49
A
9
510
0.27
2.34
52
A
10
370
0.17
1.94
46
A
11
355
0.17
1.94
44
A
12
375
0.17
1.94
45
1
5
n
[rpm]
A
6
150
50
A2a)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6E 500-AK01 -01
13.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63072-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
77
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, Ø 500
subject to alterations
Capacitor
Perm. amb. temp.
Electr. connection
M6E 094-HA
Max. current
draw (1)
R6E 500
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, riveted
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
°C
p. 596 f.
50
60
820
850
385
475
1.82
2.10
1~ 230
1~ 230
A
10.0 /400 -40 to +40
10.0 /450 -40 to +40
(1) Nominal data in operating point with maximum load
2
1,25
[Pa]
[in H O]
Curves
1,00
300
0,75
2
0,50
200
1
0,25
100
A
0
1000
1000
78
A2a)
2000
2000
3000
3000
4000
[CFM]
5000
[m3/h]
50 Hz
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
845
360
1.72
62
A
2
830
376
1.79
57
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
R6E 500-AB05 -06
11.1
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
54480-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
55
4x90˚
0
10
79
Inlet nozzle
p. 550
Guard grille
p. 553
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 560
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
1365
2.38 8.66/5.00
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 560 (2)
M4D 138-LA
A
subject to alterations
(1) Nominal data in operating point with maximum load
—
-40 to +60
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
A
3,0
800
2,5
700
3
500
2,0
600
2
6
1,5
400
300
5
1,0
9
1
200
8
4
0,5
12
100
10
0
2000
4000
3000
6000
80/140 V
80
7
11
6000
9000
100/180 V
[CFM]
12000
130/230 V
[m3/h]
230/400 V
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1380
2.14
8.33/4.81
84
A
2
1370
2.33
8.66/5.00
82
A
3
1365
2.34
8.66/5.00
81
A
4
1140
1.53
8.31/4.80
77
A
5
1110
1.62
8.75/5.05
76
A
6
1105
1.62
8.73/5.04
75
A
7
955
1.13
8.11/4.68
74
A
8
920
1.17
8.42/4.86
73
A
9
915
1.17
8.38/4.84
71
A
10
765
0.77
7.31/4.22
70
A
11
735
0.78
7.45/4.30
67
A
12
730
0.78
7.47/4.31
65
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4D 560-AQ03 -01
28.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63071-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 18 mm
81
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
Technology
Brass lead tips
AC centrifugal fans
backward curved, 3-D, Ø 560
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
885
0.78 2.95/1.70
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 560 (2)
M6D 110-IA
A
subject to alterations
(1) Nominal data in operating point with maximum load
—
-40 to +55
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
A
1,25
350
300
250
1,0
3
200
0,75
2
150
6
0,5
1
9
5
100
8
0,25
12
4
7
11
50
10
0
1000
1000
2000
2000
3000
80/140 V
82
3000
4000
5000
100/180 V
4000
6000
7000
130/230 V
[CFM]
8000
[m3/h]
230/400 V
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
905
0.68
2.71/1.56
71
A
2
890
0.76
2.87/1.65
69
A
3
890
0.76
2.85/1.64
69
A
4
665
0.48
2.85/1.64
68
A
5
610
0.49
2.89/1.67
58
A
6
605
0.49
2.88/1.66
59
A
7
595
0.32
2.31/1.34
65
A
8
560
0.33
2.40/1.39
58
A
9
565
0.33
2.39/1.38
57
A
10
480
0.21
1.99/1.15
54
A
11
450
0.21
2.03/1.17
50
A
12
450
0.18
2.03/1.17
50
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6D 560-AH05 -01
15.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63071-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 12 mm
Brass lead tips
Mounting dimensions
Ø
Technology
Ø7
5
Ø
11
Ø 130
4x90˚
0
10
83
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
28
AC centrifugal fans
backward curved, 3-D, Ø 630
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
1300
4.25 13.10/7.55
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 630 (2)
M4D 138-LA
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
-40 to +60
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
2
4,0
1000
[in H O]
Curves
A
3
3,0
800
2
2,0
600
6
400
1
5
1,0
9
200
8
12
4
7
11
10
0
2500
5000
4000
80/140 V
84
7500
8000
12000
100/180 V
10000
16000
130/230 V
[CFM]
[m3/h]
230/400 V
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1325
3.93
12.33/7.12
84
A
2
1300
4.21
13.01/7.51
82
A
3
1340
3.55
11.19/6.46
86
A
4
960
2.30
12.85/7.42
76
A
5
930
2.36
13.10/7.55
74
A
6
1005
2.19
12.13/7.01
78
A
7
745
1.50
11.32/6.53
70
A
8
725
1.54
11.49/6.63
69
A
9
785
1.46
11.03/6.37
71
A
10
575
0.94
9.47/5.47
63
A
11
550
0.94
9.54/5.51
61
A
12
610
0.93
9.34/5.39
64
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4D 630-AQ03 -01
29.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63070-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 18 mm
85
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
Technology
Brass lead tips
AC centrifugal fans
backward curved, 3-D, Ø 630
subject to alterations
Perm. amb. temp.
Electr. connection
A
Capacitor
M4D 138-NA
Max. current
draw (1)
R4D 630 (2)
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
1170
3.31 10.74/6.20
(1) Nominal data in operating point with maximum load
—
-40 to +35
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
2
4,0
1000
[in H O]
Curves
A
3,0
800
3
2,0
600
2
400
6
1
1,0
9
5
200
12
8
11
4
7
10
0
2000
4000
4000
80/140 V
86
6000
8000
100/180 V
[CFM]
8000
12000
130/230 V
16000
[m3/h]
230/400 V
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1170
3.11
10.09/5.83
81
A
2
1145
3.21
10.30/5.95
79
A
3
1200
2.84
9.18/5.30
83
A
4
785
1.42
8.06/4.65
70
A
5
760
1.42
8.09/4.67
68
A
6
830
1.35
7.65/4.41
72
A
7
640
0.93
6.77/3.91
65
A
8
625
0.93
6.78/3.92
63
A
9
685
0.89
6.52/3.76
66
A
10
520
0.59
5.57/3.22
59
A
11
510
0.59
5.56/3.21
58
A
12
550
0.57
5.40/3.12
60
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R4D 630-AW01 -01
31.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63070-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 18 mm
87
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
Technology
Brass lead tips
AC centrifugal fans
backward curved, 3-D, Ø 630
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
°C
p. 596 f.
3~ 230/400 50
880
1.31 4.85/2.80
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 630 (2)
M6D 138-HF
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
-40 to +60
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
2
2,0
500
[in H O]
Curves
A
1,5
400
3
2
1,0
300
1
6
200
5
9
0,5
4
8
100
12
7
11
10
0
2000
2000
4000
80/140 V
88
4000
6000
100/180 V
8000
6000
[CFM]
10000
[m3/h]
130/230 V
230/400 V
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
885
1.28
4.85/2.80
73
A
2
885
1.30
4.82/2.79
73
A
3
890
1.23
4.65/2.69
73
A
4
675
0.82
4.72/2.72
67
A
5
675
0.82
4.75/2.74
67
A
6
690
0.80
4.59/2.65
67
A
7
540
0.57
4.37/2.52
60
A
8
535
0.56
4.35/2.51
60
A
9
560
0.57
4.27/2.46
61
A
10
420
0.36
3.72/2.15
54
A
11
415
0.36
3.74/2.16
54
A
12
430
0.36
3.70/2.14
54
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
R6D 630-AT03 -01
27.0
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
kg
63070-2-4013
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
Depth of screw
max. 18 mm
89
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connections
p. 596 f.
Contacts
Technology
Brass lead tips
90
General
information
Ø 085 - Ø 400
92
AC centrifugal blowers with plastic housing, dual inlet
Ø 140 - Ø 160
158
AC centrifugal blowers, dual inlet
Ø 097 - Ø 250
178
91
Contacts
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
AC centrifugal fans and blowers, single inlet
AC centrifugal,
forward
AC centrifugal,
backward
AC centrifugal fans and blowers forward curved
AC centrifugal fan and blower
single inlet, Ø 085
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Current draw
M2E 042-CA
Power input
*2E 085
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
80
95
2350
2800
32
30
0.15
0.14
1.0 /400
1.0 /400
53
57
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
-25 to +60
-25 to +70
subject to alterations
2
[Pa]
[in H O]
Curves
0,6
160
0,4
120
80
2
0,2
A
40
1
0
10
20
20
30
40
40
60
50
80
50 Hz
92
[CFM]
[m3/h]
60 Hz
A
1
2430
32
0.15
A
2
2590
30
0.14
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Capacitor: FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 085-AA01 -05
0.7
G2E 085-AA01 -01
0.9
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
68 ±1
57±1
Brass lead tips
M4
47±0
20
EC centrifugal,
forward
Depth of screw
max. 4 mm
2
Ø85
Ø67
Ø59
Ø17 ±0,1
,1
Ø30
6
EC-SYSTEMS
300 ±20
Accessories
60,2
3
84
20˚
54,5
Technology
116,5
3x1
34,5
68
58
42
M4
80
300
93
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
71,5
117,5
4,5
5,5
76
66
56
Ø65-1
42
AC centrifugal fan and blower
single inlet, Ø 097
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M2E 042-CA
Power input
*2E 097
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
100
110
2050
2300
35
37
0.16
0.17
1.5 /400
1.5 /400
55
58
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +40
-25 to +55
subject to alterations
[Pa]
2
0,8
200
[in H O]
Curves
0,6
160
0,4
120
2
80
0,2
A
40
1
0
20
20
94
40
40
60
60
80
[CFM]
100
[m3/h]
50 Hz
60 Hz
A
1
2120
35
0.16
A
2
2335
33
0.15
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Capacitor: FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R2E 097-AD01 -05
0.6
G2E 097-HD01 -02
1.1
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
41,5 ±1
55,9 ±1
M4
Brass lead tips
Depth of screw
max. 4 mm
EC centrifugal,
forward
2
47±0
20
Ø97
Ø79
Ø59
Ø17±0,1
,1
Ø32
6
EC-SYSTEMS
300 ±20
40
143
75
120˚
3
56,5˚
Technology
Ø80
3
137
75
46
3x
24
1
Accessories
18
1
53
96
6
60
300
95
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
1
AC centrifugal fan and blower
single inlet, Ø 108
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Current draw
M2E 052-BF
Power input
*2E 108
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
160
160
1850
1850
30
35
0.14
0.16
1.0 /400
1.0 /400
56
56
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
-25 to +85
-25 to +80
subject to alterations
2
[Pa]
[in H O]
Curves
1,2
320
0,8
240
A
160
0,4
2
80
1
0
20
40
40
60
80
80
120
100
160
50 Hz
96
[CFM]
[m3/h]
60 Hz
A
1
2070
34
0.16
A
2
2470
31
0.15
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 108-AG63 -05
0.6
G2E 108-AG63 -01
1.3
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
63 ±1
54 ±1
M4
58 ±0
15
EC centrifugal,
forward
Brass lead tips
Depth of screw
max. 5 mm
Ø108
Ø84
Ø72
,1
Ø55
6
EC-SYSTEMS
300 ±20
52
159
79
4
Accessories
8
M4
50
83
66
115
97
76
71
Ø87-1
Technology
168
118
300
97
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
82
AC centrifugal fan and blower
single inlet, Ø 120
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Current draw
M2E 068-BF
Power input
*2E 120
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
255
265
2350
2450
80
100
0.35
0.44
2.0 /450
2.0 /450
61
62
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
-25 to +55
-25 to +60
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
1,0
300
2
200
0,5
A
100
1
0
25
40
50
80
75
120
100
160
125
200
[CFM]
240
50 Hz
98
[m3/h]
60 Hz
A
1
2460
77
0.34
A
2
2665
69
0.31
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 120-AR77 -05
1.2
G2E 120-AR77 -01
1.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
83 ±1
63 ±1
Brass lead tips
M4
58 ±0
15
EC centrifugal,
forward
Depth of screw
max. 5 mm
2
Ø120
Ø96
Ø92
Ø27±0,1
,1
Ø55
6
EC-SYSTEMS
450 ±20
62
178
82
4
Accessories
7
M4
50
83
68
115
100
76
86
Ø100 -1
Technology
184
132
450
99
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
98
AC centrifugal fans and blowers
single inlet, Ø 120
Perm. amb. temp.
Electr. connection
B
Min. back pressure
M2E 068-BF
Sound pressure level
*2E 120
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 052-BF
Power input
*2E 120
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A "F", B "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
190
185
275
255
2050
2000
2200
2050
57
66
83
100
0.25
0.29
0.37
0.45
1.5 /400
1.5 /400
2.0 /450
2.0 /450
63
63
64
63
0
0
0
0
n
[rpm]
P1
[W]
I
[A]
-25 to +55
-25 to +55
-25 to +70
-25 to +60
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
1,0
300
B
200
2
A
0,5
2
100
1
0
25
40
50
80
75
120
1
100
160
125
200
150
240
50 Hz
100
[CFM]
[m3/h]
60 Hz
A
1
2200
54
0.24
A
2
2410
51
0.23
B
1
2335
80
0.36
B
2
2580
72
0.32
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: B CCC
Dimensions
Centrifugal blower
with flange
kg
A
B
C
D
F
G
I
—
—
—
59.0
—
60.0
94.0
98.0
82.0
77.0
b
c
Centrifugal blower
without flange
1.0
42.0
48.0
G2E 120-TD76 -01
—
1.3
—
1.2
62.0
85.0
—
G2E 120-CR21 -01
1.9
110.0
kg
R2E 120-BD76 -09
R2E 120-AR21 -05
6.0
99.0
c ±1
Depth of screw
max. 5 mm
2
M4
Brass lead tips
EC centrifugal,
forward
63 ±1
58 ±0
15
Ø55
EC-SYSTEMS
Ø120
Ø96
Ø92
Ø27±0,1
,1
6
450 ±20
b
A
B
Accessories
170,5
87
˚
4x90
3
45˚
Technology
Ø95
180
101
71
C
D
67
G
F
110
6
85
I
450
101
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Centrifugal fan
EC centrifugal, backward for clean rooms
Dimensions
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal fan and blower
single inlet, Ø 133
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M2E 068-BF
Power input
*2E 133
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
245
235
2150
2100
88
110
0.39
0.49
2.0 /450
2.0 /450
65
65
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +60
-25 to +50
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
A
1,0
300
2
0,5
200
100
1
0
25
40
50
80
75
120
100
160
125
200
150
240
50 Hz
102
[CFM]
[m3/h]
60 Hz
A
1
2290
83
0.37
A
2
2530
73
0.33
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 133-AN77 -01
1.3
G2E 133-DN77 -01
1.9
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
68,5 ±1
63 ±1
M4
Brass lead tips
EC centrifugal,
forward
Depth of screw
max. 5 mm
2
58 ±0
15
Ø55
Ø133
Ø108
Ø92
Ø27±0,1
,1
EC-SYSTEMS
6
450 ±20
46
170,5
59
Accessories
˚
4x90
45˚
Technology
140
103
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
81
6
85
450
Ø112
180
3
101
71
67
87
AC centrifugal fan and blower
single inlet, Ø 140
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M2E 052-CA
Power input
*2E 140
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
240
225
1350
1300
63
70
0.29
0.31
1.5 /400
1.5 /400
55
53
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +45
-25 to +35
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
400
A
1,0
300
200
0,5
2
100
1
0
25
40
50
80
75
120
100
160
125
200
150
240
50 Hz
104
[CFM]
[m3/h]
60 Hz
A
1
1460
62
0.29
A
2
1930
56
0.26
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 140-BI52 -05
1.4
G2E 140-DI52 -01
1.9
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
45 ±1
58,8 ±1
M4
Brass lead tips
EC centrifugal,
forward
Depth of screw
max. 5 mm
58 ±0
20
Ø55
Ø140
Ø121.9
Ø92
,1
6
EC-SYSTEMS
450 ±20
37,4
216
62
Accessories
4x90
137,6
71
˚
45˚
242
3
Ø125,5
67
95
Technology
158
6
85
450
105
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
62
AC centrifugal fan and blower
single inlet, Ø 140
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
370
335
1400
1500
105
115
0.46
0.51
2.0 /450
2.0 /450
59
57
0
50
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*2E 140
M2E 068-BF
A
1~ 230
1~ 230
-25 to +40
-25 to +45
subject to alterations
2
[Pa]
[in H O]
Curves
1,2
320
2
0,8
240
A
160
0,4
1
80
0
40
80
80
120
160
160
240
200
320
50 Hz
106
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1700
98
0.43
A
2
2100
89
0.40
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 140-AE77 -05
1.2
G2E 140-AE77 -01
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
72 ±1
63 ±1
Brass lead tips
M4
58 ±0
15
EC centrifugal,
forward
Depth of screw
max. 5 mm
2
Ø55
Ø140
Ø121
Ø92
Ø27±0,1
,1
6
EC-SYSTEMS
450 ±20
59
227
M4
5
Accessories
6,3
103
92
120
105
130
115
94
158
Technology
248
107
Ø118 -1
450
107
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
100
AC centrifugal fans and blowers
single inlet, Ø 140
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
385
305
485
480
1650
1700
2400
2350
135
145
160
205
0.60
0.64
0.70
0.90
2.0 /400
2.0 /400
4.0 /400
4.0 /400
63
60
72
71
0
100
0
0
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*2E 140
M2E 068-CF
A
*2E 140
M2E 068-DF
B
1~
1~
1~
1~
-25 to +55
-25 to +40
-25 to +70
-25 to +45
subject to alterations
2
[Pa]
[in H O]
Curves
500
1,5
400
B
2
1,0
300
2
200
0,5
A
100
1
0
50
100
100
150
200
1
200
300
250
[CFM]
400
[m3/h]
50 Hz
108
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1900
128
0.57
A
2
2200
117
0.52
B
1
2485
148
0.65
B
2
2630
128
0.57
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
Centrifugal fan
kg
d
e
Centrifugal blower
with flange
kg
R2E 140-AL40 -05
1.7
73.0
25.0
G2E 140-AL40 -01
3.0
R2E 140-AI28 -05
2.1
83.0
35.0
G2E 140-AI28 -01
3.4
EC centrifugal, backward for clean rooms
Dimensions
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
72 ±1
Depth of screw
max. 5 mm
2
Brass lead tips
M4
58 ±0
e
EC centrifugal,
forward
d ±1
Ø55
EC-SYSTEMS
Ø140
Ø121
Ø92
Ø27±0,1
,1
6
450 ±20
59
227
M4
Accessories
6,3
103
5
92
120
105
130
115
94
158
Technology
248
107
Ø118 -1
450
109
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
100
AC centrifugal blowers
single inlet, Ø 140
Perm. amb. temp.
Electr. connection
B
Min. back pressure
M2E 068-CF
Sound pressure level
G2E 140
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 068-BF
Power input
G2E 140
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Heat-resistant plastic
Impeller: A heat-resistant plastic, B galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
370
315
445
390
1650
1700
2000
2150
105
115
137
155
0.46
0.51
0.60
0.68
2.0 /400
2.0 /400
3.0 /400
3.0 /400
59
57
65
64
0
50
0
130
-25 to +55
-25 to +40
-25 to +65
-25 to +50
subject to alterations
2
[Pa]
[in H O]
Curves
500
400
1,5
B
A
300
1,0
2
2
200
0,5
1
100
1
0
50
100
100
150
200
200
[CFM]
300
[m3/h]
50 Hz
110
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1910
98
0.43
A
2
2280
86
0.38
B
1
2220
123
0.54
B
2
2470
105
0.46
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
kg
G2E 140-NS38 -01
1.6
G2E 140-NL33 -01
1.6
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
EC centrifugal,
forward
237
113
111
Ø101
100
95
EC-SYSTEMS
6
450 ±20
5
Accessories
Brass lead tips
Technology
3
111
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
22 ±0,3
Ø125,5
248
261 ±1
267 ±1
85
AC centrifugal fan and blower
single inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Current draw
M2E 068-CA
Power input
*2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
470
380
1550
1750
140
155
0.62
0.68
3.0 /450
3.0 /450
60
58
0
100
1~ 230
1~ 230
-25 to +50
-25 to +40
subject to alterations
[Pa]
2
2,0
500
[in H O]
Curves
A
1,5
400
1,0
300
2
0,5
200
100
1
0
50
100
100
150
200
200
300
250
400
50 Hz
112
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1835
136
0.60
A
2
2070
126
0.56
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R2E 146-AW07 -05
1.4
G2E 146-DW07 -01
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
72±1
68 ±1
Brass lead tips
M4
58 ±0
20
EC centrifugal,
forward
Depth of screw
max. 5 mm
2
Ø146
Ø127
Ø92
Ø27 ±0,1
,1
Ø55
6
EC-SYSTEMS
450 ±20
62
227
M4
5
Accessories
6,3
101
92
120
105
130
115
94
158
Technology
248
107
Ø125,5 -1
450
113
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
104
AC centrifugal fans and blowers
single inlet, Ø 160
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
600
570
410
445
2100
2100
1300
1400
240
280
67
90
1.05
1.23
0.30
0.40
6.0 /400
6.0 /400
2.0 /450
2.0 /450
72
71
65
67
0
50
0
0
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*2E 160
M2E 068-EC
A
*4E 160
M4E 068-CF
B
1~
1~
1~
1~
-25 to +50
-25 to +40
-25 to +65
-25 to +65
subject to alterations
2,5
700
400
A
2
1,5
500
2,0
600
1,0
300
200
0,5
B
2
100
1
1
0
100
100
200
200
300
300
400
[CFM]
500
[m3/h]
50 Hz
114
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2210
223
0.98
A
2
2525
172
0.76
B
1
1350
63
0.28
B
2
1395
58
0.26
2
[Pa]
[in H O]
Curves
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: A variable, B lateral
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal fan
kg
d
e
Centrifugal blower
with flange
kg
R2E 160-AY47 -01
2.6
91.0
42.0
G2E 160-AY47 -01
3.9
R4E 160-AB01 -01
1.7
72.0
25.0
G4E 160-AB01 -01
2.9
EC centrifugal, backward for clean rooms
Dimensions
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
72±1
Depth of screw
max. 5 mm
2
Brass lead tips
M4
58 ±0
e
EC centrifugal,
forward
d ±1
Ø55
6
EC-SYSTEMS
Ø160
Ø131
Ø92
Ø27 ±0,1
,1
450 ±20
62
227
M4
Accessories
6,3
103
5
92
120
105
130
115
94
175
Technology
248
107
Ø130 -1
450
115
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
100
AC centrifugal fan and blower
single inlet, Ø 180
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
760
630
575
594
1950
2150
1250
1300
400
415
110
145
1.75
1.82
0.49
0.64
8.0 /400
8.0 /400
3.0 /450
3.0 /450
73
71
65
65
0
250
0
0
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: A coated in black, B partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
G2E 180
M2E 074-EI
A
*4E 180
M4E 068-DF
B
1~
1~
1~
1~
-25 to +40
-25 to +40
-25 to +55
-25 to +45
subject to alterations
[Pa]
[in H2O]
Curves
3,0
800
A
600
2,0
2
400
1,0
1
B
200
2
1
100
0
100
200
200
300
300
400
500
400
600
700
50 Hz
116
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2290
335
1.47
A
2
2600
255
1.12
B
1
1300
105
0.47
B
2
1385
92
0.41
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
e
Centrifugal blower
with flange
kg
—
—
48.0
G2E 180-EH03 -01
5.6
R4E 180-AB01 -05
1.7
35.0
G4E 180-AB01 -01
3.7
89 ±1
Depth of screw
max. 5 mm
2
M4
Brass lead tips
EC centrifugal,
forward
82 ±1
58 ±0
e
Ø55
EC-SYSTEMS
Ø180
Ø149
Ø92
Ø27±0,1
,1
6
450 ±20
75
261
Accessories
7
M4
5
194
Technology
281
450
123
Motor
protruding
by 15 mm!
Ø150-1
A
120
110
140
120
125
110
86
105
117
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Air filter
p. 563
Electr. connections
p. 596 f.
Contacts
Centrifugal fan
EC centrifugal, backward for clean rooms
Dimensions
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal fan and blower
single inlet, Ø 180
subject to alterations
Perm. amb. temp.
Electr. connection
B
Min. back pressure
M4D 074-DF
Sound pressure level
G4D 180 (1)(2)
3~
3~
3~
3~
Capacitor
A
Current draw
M4D 074-DF
Power input
*4D 180 (2)
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230/400
230/400
230/400
230/400
50
60
50
60
1010
1090
1110
1180
1330
1440
1290
1370
175
240
195
265
0.68/0.39
0.74/0.43
0.69/0.40
0.81/0.47
(1) data collected via exhaust duct (step diffuser, 1 m length)
—
—
—
—
2
[Pa]
[in H O]
1,25
1,0
250
B
2
0,75
200
150
0,5
2
A
100
0,25
1
50
1
0
200
200
118
400
400
600
800
600
[CFM]
1000
[m3/h]
50 Hz
60 Hz
0
0
0
0
-25 to +60
-25 to +55
-25 to +60
-25 to +45
n
[rpm]
P1
[W]
I
[A]
(2) 230 VAC ∆ / 400 VAC Y
Curves
300
67
69
69
70
A
1
1360
160
0.62/0.36
A
2
1410
120
0.46/0.27
B
1
1360
163
0.58/0.33
B
2
1420
105
0.38/0.22
C1)/C2)
C1)/C2)
General
information
AC centrifugal,
backward
Motor protection: Without thermal protection
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal blower
with flange (large)
kg
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
Centrifugal blower
with flange (small)
R4D 180-AF20 -05
3.2
G4D 180-FF20 -01
—
6.4
188.0 168.0 134.0
—
—
—
G4D 180-GF20 -01
6.4
278.0 258.0 224.0 180.0
C
D
E
S
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
90.0
120,5 ±1
90 ±0,2
Depth of screw
max. 10 mm
EC centrifugal,
forward
104 ±1
5
37
Ø180
Ø149
Ø102
35
6
EC-SYSTEMS
60
0±
20
Ø75 ±0,1
M6
92
Brass lead tips
183
129
296
90
Accessories
7
163
133
E
˚
60
5˚
Technology
332
6x
Ø149 -1
192
136
600
3,2
155
119
Inlet nozzle
p. 552
Guard grille
p. 554
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
Hole with
large flange only
C
D
S
B
AC centrifugal fan and blower
single inlet, Ø 180
subject to alterations
Perm. amb. temp.
Electr. connection
B
Min. back pressure
M4E 074-DF
Sound pressure level
G4E 180 (1)
1~
1~
1~
1~
Capacitor
A
Current draw
M4E 074-DF
Power input
*4E 180
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
965
935
1030
910
1220
1200
1130
1170
160
197
180
200
0.71
0.87
0.80
0.88
4.0 /400
4.0 /400
4.0 /400
4.0 /400
66
65
66
64
0
0
0
50
(1) data collected via exhaust duct (step diffuser, length 1 m)
2
[Pa]
[in H O]
Curves
1,0
300
250
0,75
B
200
150
2
0,5
2
A
0,25
100
50
1
0
200
200
400
400
600
1
[CFM]
800
[m3/h]
50 Hz
120
-25 to +60
-25 to +40
-25 to +45
-25 to +35
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1280
142
0.63
A
2
1375
112
0.50
B
1
1210
160
0.71
B
2
1340
123
0.55
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal blower
with flange (large)
kg
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
Centrifugal blower
with flange (small)
R4E 180-AS11 -05
3.2
G4E 180-FS11 -01
—
6.4
188.0 168.0 134.0
—
—
—
G4E 180-GS11 -01
6.4
278.0 258.0 224.0 180.0
C
D
E
S
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
90.0
120,5 ±1
90 ±0,2
Depth of screw
max. 10 mm
EC centrifugal,
forward
104 ±1
5
37
Ø180
Ø149
Ø102
35
6
EC-SYSTEMS
60
0±
20
Ø75 ±0,1
M6
92
Brass lead tips
183
129
296
90
7
163
133
Accessories
Hole with
large flange only
E
C
D
S
˚
60
5˚
Technology
332
6x
192
Ø149 -1
600
136
3,2
155
121
Inlet nozzle
p. 552
Guard grille
p. 554
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
B
AC centrifugal fan and blower
single inlet, Ø 200
subject to alterations
W
A
230/400
230/400
230/400
230/400
50
60
50
60
1375
1360
1665
1220
1350
1530
1300
1550
285
360
360
340
1.00/0.58
1.13/0.65
1.14/0.66
1.07/0.62
(1) data collected via exhaust duct (step diffuser, 1 m length)
Electr. connection
rpm
Perm. amb. temp.
B
m3/h
Min. back pressure
M4D 074-EI
Hz
Sound pressure level
G4D 200 (1)(2)
3~
3~
3~
3~
VAC
Capacitor
A
Current draw
M4D 074-EI
Power input
*4D 200 (2)
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
µF/VDB
dB(A)
Pa
°C
p. 596 f.
69
69
71
69
0
100
0
250
—
—
—
—
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
1,5
400
350
B
250
1,0
300
200
2
2
0,5
150
100
A
50
1
1
0
200
400
400
600
800
800
[CFM]
1200
[m3/h]
50 Hz
122
60 Hz
-25 to +45
-25 to +45
-25 to +45
-25 to +40
n
[rpm]
P1
[W]
I
[A]
A
1
1375
255
0.90/0.52
A
2
1415
192
0.68/0.39
B
1
1315
330
1.05/0.61
B
2
1385
230
0.74/0.43
C1)/C2)
C1)/C2)
General
information
AC centrifugal,
backward
Motor protection: Without thermal protection
Cable exit: Axial
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal blower
with flange (large)
kg
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
Centrifugal blower
with flange (small)
R4D 200-AL12 -05
3.7
G4D 200-BL12 -01
—
7.0
200.0 180.0 146.0
—
—
—
G4D 200-CL12 -01
7.0
304.0 284.0 250.0 180.0
C
D
E
S
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
90.0
129 ± 1
90 ± 0,2
Depth of screw
max. 10 mm
EC centrifugal,
forward
117± 1
5
37
Ø202
Ø176
Ø102
48
6
EC-SYSTEMS
60
0±
20
Ø75 ± 0,1
M6
102
Brass lead tips
196,5
142,5
327
90
146
Accessories
Hole with
large flange only
7
176,5
E
C
D
S
˚
60
5˚
Technology
370
6x
213
Ø 175
600
151
3,2
160,5
123
Inlet nozzle
p. 552
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
B
AC centrifugal fans and blowers
single inlet, Ø 200
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1370
1315
1540
1300
1300
1480
1240
1430
280
350
330
370
1.25
1.55
1.45
1.62
8.0 /400
8.0 /400
8.0 /400
8.0 /400
69
69
70
68
0
100
0
170
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*4E 200
M4E 074-EI
A
G4E 200 (1)
M4E 074-EI
B
subject to alterations
1~
1~
1~
1~
(1) data collected via exhaust duct (step diffuser, length 1 m)
2
[Pa]
[in H O]
Curves
1,5
400
350
B
1,0
300
250
200
2
2
0,5
150
A
100
50
1
1
0
200
400
400
600
800
800
1200
[CFM]
[m3/h]
50 Hz
124
-25 to +40
-25 to +40
-25 to +50
-25 to +40
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1350
258
1.15
A
2
1400
214
0.96
B
1
1285
303
1.33
B
2
1370
242
1.07
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Axial
Protection class: I
Capacitor: FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, B also GOST
Centrifugal blower
with flange (large)
kg
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
Centrifugal blower
with flange (small)
R4E 200-AL03 -05
3.7
G4E 200-BL03 -01
—
7.0
200.0 180.0 146.0
—
—
—
G4E 200-CL03 -01
7.0
304.0 284.0 250.0 180.0
C
D
E
S
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
90.0
129 ± 1
90 ± 0,2
Depth of screw
max. 10 mm
EC centrifugal,
forward
117± 1
5
37
Ø202
Ø176
Ø102
48
6
EC-SYSTEMS
60
0±
20
Ø75 ± 0,1
M6
102
Brass lead tips
196,5
142,5
327
90
146
Accessories
Hole with
large flange only
7
176,5
E
C
D
S
˚
60
5˚
Technology
370
6x
213
Ø 175
600
151
3,2
160,5
125
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Terminal box
p. 562
Electr. connections
p. 596 f.
Contacts
B
AC centrifugal fan and blower
single inlet, Ø 225
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
400 Y
400 Y
400 Y
400 Y
50
60
50
60
1350
1500
1310
1520
380
540
460
515
0.75
0.94
0.85
0.90
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*4D 225
M4D 094-FA
A
G4D 225 (2)
M4D 094-FA
B
subject to alterations
3~
3~
3~
3~
(1) Nominal data in operating point with maximum load
—
—
—
—
0
50
0
200
-40 to +90
-40 to +55
-40 to +75
-40 to +60
1,0
300
2
2
200
0,5
A
100
1
0
250
400
500
800
1
750
1200
1000
1600
50 Hz
126
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1380
325
0.69
71
A
2
1420
228
0.60
67
B
1
1345
388
0.76
74
B
2
1400
271
0.64
69
2
[Pa]
[in H O]
1,5
B
D2)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
400
D2)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Options: B 400 VAC ∆/Y for two speed steps available on request
kg
EC centrifugal,
backward
Centrifugal fan
kg
R4D 225-AK10 -06
6.5
G4D 225-FK10 -03
—
9.5
200.0 180.0 146.0
—
—
—
G4D 225-GK10 -03
9.7
304.0 284.0 250.0 180.0
C
D
E
S
90.0
137,5 ±2
128 ±2
225 ±2
Ø124
Ø195 ±1
50
60
0
Ø100 +0,5
15
Ø1
EC centrifugal,
forward
5,5
Centrifugal blower
with flange (large)
Dimensions
Centrifugal blower
with flange (small)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
45˚
M6
Depth of screw
max. 12 mm
EC-SYSTEMS
102
Brass lead tips
196,5
142,5
327
90
Accessories
158
E
˚
60
6x
5˚
370
0
60
Technology
7
176,5
151
Ø194
242
3,2
166,5
5,5
127
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
Hole with
large flange only
C
D
S
B
AC centrifugal fan and blower
single inlet, Ø 225
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1330
1500
1260
1470
395
500
485
510
1.98
2.30
2.30
2.30
6.0 /450
6.0 /450
6.0 /450
6.0 /450
0
100
0
200
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*4E 225
M4E 094-FA
A
G4E 225 (2)
M4E 094-FA
B
subject to alterations
1~
1~
1~
1~
(1) Nominal data in operating point with maximum load
-40 to +70
-40 to +50
-40 to +55
-40 to +45
1,0
300
2
2
200
0,5
A
1
100
0
250
400
500
800
1
750
1200
1000
1600
50 Hz
128
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1365
339
1.75
67
A
2
1415
255
1.46
70
B
1
1320
401
2.00
74
B
2
1395
292
1.57
69
2
[Pa]
[in H O]
1,5
B
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
400
A2a)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
kg
EC centrifugal,
backward
Centrifugal fan
kg
R4E 225-BK05 -03
6.6
G4E 225-DK05 -03
—
9.6
200.0 180.0 146.0
—
—
—
G4E 225-EK05 -03
9.8
304.0 284.0 250.0 180.0
C
D
E
S
90.0
137,5 ±2
128 ±2
225 ±2
Ø124
Ø195 ±1
50
60
0
Ø100 +0,5
15
Ø1
EC centrifugal,
forward
5,5
Centrifugal blower
with flange (large)
Dimensions
Centrifugal blower
with flange (small)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
45˚
M6
Depth of screw
max. 12 mm
EC-SYSTEMS
102
Brass lead tips
196,5
142,5
327
90
Accessories
158
E
˚
60
6x
5˚
370
0
60
Technology
7
176,5
151
Ø194
242
3,2
166,5
5,5
129
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Hole with
large flange only
C
D
S
B
AC centrifugal fan and blower
single inlet, Ø 250
B
subject to alterations
Electr. connection
M4D 094-HA
Perm. amb. temp.
G4D 250 (2)
3~
3~
3~
3~
Min. back pressure
A
Capacitor
M4D 094-HA
Max. current
draw (1)
*4D 250
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
400 Y
400 Y
400 Y
400 Y
50
60
50
60
1350
1560
1280
1560
590
710
800
700
1.17
1.26
1.46
1.24
(1) Nominal data in operating point with maximum load
—
—
—
—
0
150
0
300
-40 to +80
-40 to +60
-40 to +50
-40 to +55
2
[Pa]
[in H O]
2,0
1,5
400
B
300
2
1,0
2
200
A
1
0,5
1
100
0
250
400
500
750
1000
1000
1600
1250
[CFM]
2200
50 Hz
130
[m3/h]
60 Hz
D2)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
D2)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1390
444
0.99
72
A
2
1430
312
0.87
70
B
1
1330
654
1.13
76
B
2
1410
386
0.94
71
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Options: 400 VAC ∆/Y for two speed steps available on request
kg
EC centrifugal,
backward
Centrifugal fan
kg
R4D 250-AC10 -03
9.7
G4D 250-DC10 -03
—
13.1
218.0 190.0 167.0
—
—
—
G4D 250-EC10 -03
13.5
313.0 285.0 262.0 180.0 293.0
C
D
E
S
U
90.0 198.0
175,5 ±2
148 ±2
Ø240±2
Ø124
Ø192 ±1
70
60
0
Ø100 +0.5
15
Ø1
EC centrifugal,
forward
5,5
Centrifugal blower
with flange (large)
Dimensions
Centrifugal blower
with flange (small)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
45˚
EC-SYSTEMS
M6
Depth of screw
max. 12 mm
Brass lead tips
227
206
176
387
90
7
207
194
Accessories
Hole with
large flange only
E
C
U
D
S
0˚
0
60
Technology
392
6x6
275
173
Ø200
B
3,2
205,5
5,5
131
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
140
AC centrifugal fan and blower
single inlet, Ø 250
B
subject to alterations
Electr. connection
M4E 094-HA
Perm. amb. temp.
G4E 250(2)
1~
1~
1~
1~
Min. back pressure
A
Capacitor
M4E 094-HA
Max. current
draw (1)
*4E 250
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1310
1470
1150
1400
570
690
760
730
2.48
3.05
3.80
3.30
10.0 /450
10.0 /450
10.0 /450
10.0 /450
0
100
0
220
(1) Nominal data in operating point with maximum load
-40 to +70
-40 to +55
-40 to +45
-40 to +55
2
[Pa]
[in H O]
2,0
1,5
400
300
2
1,0
2
B
200
0,5
1
1
A
100
0
250
400
500
750
1000
1000
1600
1250
[CFM]
2200
50 Hz
132
[m3/h]
60 Hz
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
A2a)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1370
448
2.25
70
A
2
1420
325
1.85
68
B
1
1310
560
2.73
73
B
2
1390
395
2.05
69
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
kg
EC centrifugal,
backward
Centrifugal fan
kg
R4E 250-BA09 -03
9.3
G4E 250-DA09 -03
—
12.7
218.0 190.0 167.0
—
—
—
G4E 250-EA09 -03
13.1
313.0 285.0 262.0 180.0 293.0
C
D
E
S
U
90.0 198.0
175,5 ±2
148 ±2
Ø240±2
Ø124
Ø192 ±1
70
60
0
Ø100 +0.5
15
Ø1
EC centrifugal,
forward
5,5
Centrifugal blower
with flange (large)
Dimensions
Centrifugal blower
with flange (small)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
45˚
EC-SYSTEMS
M6
Depth of screw
max. 12 mm
Brass lead tips
227
206
176
387
90
7
207
194
Accessories
Hole with
large flange only
E
C
U
D
S
0˚
0
60
Technology
392
6x6
275
173
Ø200
B
3,2
205,5
5,5
133
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
140
AC centrifugal fan and blowers
single inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
850
900
780
760
220
295
255
305
1.00
1.30
1.15
1.35
6.0 /450
6.0 /500
6.0 /450
6.0 /500
0
0
0
0
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
*6E 250
M6E 094-FA
A
G6E 250 (2)
M6E 094-FA
B
subject to alterations
1~
1~
1~
1~
(1) Nominal data in operating point with maximum load
-40 to +80
-40 to +80
-40 to +80
-40 to +70
0,5
150
2
2
100
0,25
A
1
1
50
0
250
400
500
800
750
1200
1000
1600
50 Hz
134
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
900
180
0.82
63
A
2
930
156
0.74
61
B
1
855
215
0.96
65
B
2
910
173
0.79
62
2
[Pa]
[in H O]
0,75
B
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
200
A2a)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
kg
EC centrifugal,
backward
Centrifugal fan
kg
R6E 250-AK05 -03
7.0
G6E 250-DK05 -03
—
10.5
218.0 190.0 167.0
—
—
—
G6E 250-EK05 -03
10.9
313.0 285.0 262.0 180.0 293.0
C
D
E
S
U
90.0 198.0
175,5 ±2
128 ±2
Ø240±2
Ø124
Ø192 ±1
50
60
0
Ø100 +0.5
15
Ø1
EC centrifugal,
forward
5,5
Centrifugal blower
with flange (large)
Dimensions
Centrifugal blower
with flange (small)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
45˚
EC-SYSTEMS
M6
Depth of screw
max. 12 mm
Brass lead tips
227
206
176
387
90
7
207
194
Accessories
Hole with
large flange only
E
C
U
D
S
0˚
0
60
Technology
392
6x6
275
173
Ø200
B
3,2
205,5
5,5
135
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
140
AC centrifugal fans
single inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
1400
0.75 2.77/1.60
B
1~ 230
1270
0.64
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 250 (2)
M4D 110-GF
R4E 250
M4E 110-GF
subject to alterations
50
(1) Nominal data in operating point with maximum load
2.80
—
12.0 /450
0
-25 to +80
D1)/D2)
0
-25 to +80
A2a)
(2) 230 VAC ∆ / 400 VAC Y
2
1,4
[Pa]
300
2
2
1,2
350
[in H O]
Curves
1,0
A
250
B
1
0,4
0,6
100
50
0,2
150
0,8
1
200
0
250
400
136
500
800
750
1200
1000
1600
1250
2000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
1430
0.53
2.48/1.43
77
A
2
1460
0.32
2.23/1.29
70
B
1
1370
0.49
2.14
76
B
2
1430
0.33
1.49
70
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R4D 250-CG01 -01
R4E 250-CG01 -01
Inlet nozzle
Flange
12.0
25010-2-4013
94250-2-4017
12.0
25010-2-4013
94250-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
150
4x90˚
30˚
Ø 130
147
28
137
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
30
˚
158
170
184
Technology
203
30
˚
30˚
˚
30
198
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
11
30˚
25˚
230
Ø
267
247
287
Ø7
AC centrifugal fans
single inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
Type
Motor
R6D 250 (2)
M6D 110-EF
R6E 250
M6E 094-FA
subject to alterations
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
930
0.27 1.25/0.72
B
1~ 230
800
0.26
50
(1) Nominal data in operating point with maximum load
1.16
—
0
-25 to +95
D1)/D2)
6.0 /450
0
-25 to +90
A2a)
(2) 230 VAC ∆ / 400 VAC Y
[Pa]
[in H2O]
Curves
A
160
0,6
B
2
2
0,4
120
80
0,2
11
40
B
A
200
0
200
138
400
400
600
none
VAC
Curve
Nominal data
B
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: A cast in aluminium, B coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: A on rotor and stator sides,
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
600
800
1000
800
1200
1400
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
945
0.23
1.18/0.68
68
A
2
965
0.17
1.11/0.64
63
B
1
875
0.22
1.00
67
B
2
930
0.17
0.81
62
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: A VDE (acc. to EN 60034)
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
l
R6D 250-CE01 -01
9.5
R6E 250-CA08 -01
7.0
Inlet nozzle
Flange
800.0
25010-2-4013
94250-2-4017
600.0
25010-2-4013
94250-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
150
Mounting dimensions
B
A
55
Ø 130
4x90˚
4x90˚
30˚
28
28
139
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
30
˚
158
170
184
Technology
203
30
˚
0
10
30˚
5
Ø
147
11
˚
30
198
Ø
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
11
30˚
25˚
230
Ø7
Ø
267
247
287
Ø7
AC centrifugal fan and blower
single inlet, Ø 280
subject to alterations
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
M4E 094-HA
Max. current
draw (1)
*4E 280
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
50
60
1100
1350
1080
990
5.30
4.70
12.0 /400
12.0 /450
100
400
1~ 230
1~ 230
A
-40 to +60
-40 to +55
(1) Nominal data in operating point with maximum load
3,0
800
600
2,0
A
2
400
1,0
1
200
200
400
400
600
800
800
1200
1000
1600
1200
2000
50 Hz
140
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1250
845
4.20
73
A
2
1380
555
3.02
73
2
[Pa]
[in H O]
Curves
0
A2a)
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Centrifugal fan
kg
Centrifugal blower
with flange (small)
kg
R4E 280-CC21 -01
10.2
G4E 280-CA21 -01
14.0
5,5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
149,5 ±2
148 ±2
EC centrifugal,
forward
Ø280±2
Ø124
Ø234 ±1
60
0
Ø100 +0.5
15
Ø1
70
45˚
EC-SYSTEMS
M6
Depth of screw
max. 12 mm
Brass lead tips
200
176
149
412
100
Accessories
M6
0
60
Technology
444
10
280
348
322
316
200
180
190
175
Ø236
315
5x6
0˚
172
3,5
141
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
114
AC centrifugal fans
single inlet, Ø 280
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
1330
1.32 4.75/2.75
B
1~ 230
1230
1.05
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 280 (2)
M4D 110-IA
R4E 280
M4E 110-IA
subject to alterations
50
(1) Nominal data in operating point with maximum load
4.75
—
16.0 /450
0
-25 to +65
D1)/D2)
100
-25 to +50
A2a)
(2) 230 VAC ∆ / 400 VAC Y
1390
0.87
3.79/2.19
77
2
1440
0.51
3.29/1.90
72
B
1
1340
0.82
3.59
76
B
2
1425
0.54
2.34
72
2
[Pa]
1
2,0
1,6
B
1
200
0,8
100
0,4
1,2
1
300
0
500
500
142
LpA
[dB(A)]
A
A
400
I
[A]
A
2
500
P1
[kW]
[in H O]
600
n
[rpm]
2,4
Curves
1000
1000
1500
[CFM]
1500
2000
2500
3000
[m3/h]
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R4D 280-CI03 -01
R4E 280-CI01 -01
Inlet nozzle
Flange
14.5
28010-2-4013
10280-2-4017
14.5
28010-2-4013
10280-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
180
4x90˚
30˚
Ø 130
152
28
143
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
˚
30
148
161
172
˚
30
183
Technology
205
30
˚
30˚
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
11
30˚
25˚
218
Ø
254
236
266
Ø7
AC centrifugal fans
single inlet, Ø 280
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
Type
Motor
R6D 280 (2)
M6D 110-EF
R6E 280
M6E 094-HA
subject to alterations
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
870
0.45 1.56/0.90
B
1~ 230
795
0.42
50
(1) Nominal data in operating point with maximum load
1.95
—
12.0 /450
0
-25 to +70
D1)/D2)
0
-25 to +55
A2a)
(2) 230 VAC ∆ / 400 VAC Y
2
1,25
[Pa]
[in H O]
Curves
2
2
A
0,75
200
1,0
300
250
B
1
150
0,5
1
0,25
100
50
0
400
400
144
800
800
none
VAC
Curve
Nominal data
B
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: A cast in aluminium, B coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: A on rotor and stator sides,
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
1200
1200
1600
2000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
930
0.29
1.30/0.75
66
A
2
960
0.18
1.16/0.67
61
B
1
890
0.34
1.60
66
B
2
940
0.27
1.37
61
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: A VDE (acc. to EN 60034)
EC centrifugal,
backward
Dimensions
Centrifugal fan
kg
l
R6D 280-CE01 -01
10.0
R6E 280-CC05 -01
9.5
Inlet nozzle
Flange
800.0
28010-2-4013
10280-2-4017
600.0
28010-2-4013
10280-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
180
Mounting dimensions
B
A
55
Ø 130
4x90˚
4x90˚
30˚
28
28
145
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
˚
30
148
161
172
Technology
205
30
˚
0
10
30˚
5
Ø
152
11
˚
30
183
Ø
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
11
30˚
25˚
218
Ø7
Ø
254
236
266
Ø7
AC centrifugal fan
single inlet, Ø 310
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
3~ 230/400 50
1310
2.18 6.75/3.90
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 310 (2)
M4D 138-HF
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
0
-25 to +55
(2) 230 VAC ∆ / 400 VAC Y
A
2
[Pa]
[in H O]
Curves
600
300
1,2
200
0,8
400
1,6
500
2,0
2
0,4
1
100
0
500
1000
146
1000
1500
2000
2000
3000
2500
4000
[CFM]
[m3/h]
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
1330
1.96
6.29/3.63
82
A
2
1410
1.12
4.43/2.56
77
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R4D 310-CK03 -01
24.5
Inlet nozzle
Flange
31010-2-4013
38310-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
18
186
30˚
30˚
176
30
30˚ 30˚
200
147
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
214
229
246
˚
30
˚
30˚
264
Technology
30˚
25˚
283
249
325
303
349
184
AC centrifugal fans
single inlet, Ø 310
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
840
0.76 2.50/1.45
B
1~ 230
800
0.77
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 310 (2)
M6D 110-GF
R6E 310
M6E 110-IA
subject to alterations
50
(1) Nominal data in operating point with maximum load
3.37
—
16.0 /400
50
-25 to +50
D1)/D2)
0
-25 to +65
A2a)
(2) 230 VAC ∆ / 400 VAC Y
1
870
0.65
2.25/1.30
72
2
930
0.40
1.75/1.01
67
B
1
900
0.58
2.81
70
B
2
950
0.42
2.32
65
2
[Pa]
LpA
[dB(A)]
A
250
1,0
200
0,8
2
1
0,6
A
B
100
0,4
50
0,2
1
0
250
500
148
I
[A]
A
2
150
P1
[kW]
[in H O]
300
n
[rpm]
1,2
Curves
500
1000
1000
750
1500
1250
2000
1500
2500
1750
[CFM]
3000
[m3/h]
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R6D 310-CG03 -01
R6E 310-CI01 -01
Inlet nozzle
Flange
12.5
31010-2-4013
10310-2-4017
15.0
31010-2-4013
10310-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
184
4x90˚
30˚
Ø 130
186
28
149
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
˚
30
200
214
229
˚
30
246
Technology
249
30
˚
30˚
18
30˚ 30˚
0
10
30˚
264
5
176
Ø
65
˚
11
30˚
25˚
283
Ø
325
303
349
Ø7
AC centrifugal fan
single inlet, Ø 355
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
3~ 230/400 50
1300
4.36 13.75/7.95
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 355 (2)
M4D 138-LA
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
0
-25 to +70
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
A
2
600
2,4
500
2,0
700
2,8
800
0,8
1,2
200
100
0,4
300
1,6
1
400
0
1000
1000
150
2000
2000
3000
3000
4000
5000
4000
6000
7000
[CFM]
[m3/h]
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
1370
3.20
10.58/6.11
86
A
2
1430
1.89
7.52/4.34
80
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R4D 355-CM03 -01
28.0
Inlet nozzle
Flange
35510-2-4013
38355-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
18
207
30˚
30˚
196
30
30˚ 30˚
222
151
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
238
256
274
˚
30
˚
30˚
294
Technology
30˚
25˚
315
280
362
338
389
203
AC centrifugal fans
single inlet, Ø 355
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
865
0.90 3.05/1.77
B
1~ 230
830
0.83
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 355 (2)
M6D 110-IA
R6E 355
M6E 110-IA
subject to alterations
50
(1) Nominal data in operating point with maximum load
3.90
—
16.0 /400
250
-25 to +50
D1)/D2)
175
-25 to +55
A2a)
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
400
2
2
1,2
1
300
A
200
0,8
B
100
0,4
1
0
500
1000
152
1000
1500
2000
2000
3000
2500
4000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
890
0.78
2.82/1.63
70
A
2
920
0.59
2.44/1.41
68
B
1
830
0.83
3.90
70
B
2
890
0.61
2.90
67
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R6D 355-CI05 -01
R6E 355-CI01 -01
Inlet nozzle
Flange
15.5
35510-2-4013
10355-2-4017
15.5
35510-2-4013
10355-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Mounting dimensions
203
4x90˚
30˚
Ø 130
207
28
153
Inlet nozzle
p. 552
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
˚
30
222
238
256
˚
30
274
Technology
280
30
˚
30˚
18
30˚ 30˚
0
10
30˚
294
5
196
Ø
65
˚
11
30˚
25˚
315
Ø
362
338
389
Ø7
AC centrifugal fan
single inlet, Ø 400
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
3~ 230/400 50
1210
4.92 14.70/8.50
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 400 (2)
M4D 138-NA
subject to alterations
A
(1) Nominal data in operating point with maximum load
—
550 (3) -25 to +35
(2) 230 VAC ∆ / 400 VAC Y
(3) without voltage control
4,0
800
3,2
2
1000
600
2,4
[Pa]
[in H O]
Curves
A
2
400
1,6
200
0,8
1
0
1000
2000
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
ohne Spannungssteuerung einsetzbar
154
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
1210
4.92
14.70/8.50
87
A
2
1300
3.70
11.19/6.46
86
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R4D 400-CO01 -01
32.5
Inlet nozzle
Flange
40010-2-4013
38400-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
20
233
30˚
30˚
220
30
30˚ 30˚
250
155
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
268
288
308
˚
30
˚
30˚
331
Technology
30˚
25˚
355
316
408
380
437
228
AC centrifugal fans
single inlet, Ø 400
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
µF/VDB
Pa
°C
p. 596 f.
A
3~ 230/400 50
840
2.40 8.47/4.90
—
0
-25 to +75
D1)/D2)
B
3~ 230/400 50
615
0.89 3.46/2.00
—
100
-25 to +65
D1)/D2)
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: A IP 20, B IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: A none, B on rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 400 (2)
M6D 138-LA
R8D 400 (2)
M8D 138-HF
subject to alterations
(1) Nominal data in operating point with maximum load
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
500
1,6
300
1,2
A
2
0,8
1
200
B
1
0,4
100
0
500
1000
156
1000
2000
1500
2000
3000
2500
4000
3000
5000
3500
[CFM]
6000
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
A
1
890
1.86
7.10/4.10
80
A
2
940
1.16
5.51/3.18
74
B
1
615
0.89
3.46/2.00
71
B
2
675
0.60
2.74/1.58
67
2
400
n
[rpm]
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: VDE (acc. to EN 60034)
Centrifugal fan
kg
R6D 400-CM05 -01
R8D 400-CK05 -01
Inlet nozzle
Flange
29.0
40010-2-4013
38400-2-4017
26.0
40010-2-4013
38400-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
–
–
–
–
Brass lead tips
View Z
Accessories
Housing width
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
20
233
30˚
30˚
220
30
30˚ 30˚
250
157
Inlet nozzle
p. 552
Electr. connections
p. 596 f.
Contacts
268
288
308
˚
30
˚
30˚
331
Technology
30˚
25˚
355
316
408
380
437
228
AC centrifugal blowers
dual inlet, Ø 140
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
470
430
1150
1050
130
130
0.58
0.58
2.0 /400
2.0 /400
58
56
0
0
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
1~ 230
1~ 230
-25 to +50
-25 to +40
Electr. connection
Capacitor
A
Current draw
M2E 068-CF
Power input
D2E 140
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
400
300
p4
Ste
1,0
2
4
p3
Ste
200
0,5
6
1
Ste
p2
100
ep
St
8
3
1
5
7
0
100
100
200
200
300
300
400
500
50 Hz
158
[CFM]
[m3/h]
60 Hz
A
1
1675
118
0.51
56
A
2
2235
100
0.43
59
A
3
1385
93
0.41
52
A
4
2020
80
0.36
56
A
5
1000
73
0.33
46
A
6
1540
68
0.31
49
A
7
690
56
0.26
36
A
8
1015
55
0.25
38
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE
D2E 140-HR97 -07
2.3
EC centrifugal, backward for clean rooms
kg
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
159
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
520
375
1350
1400
120
125
0.53
0.55
3.0 /400
3.0 /400
51
53
50
100
1~ 230
1~ 230
A
-25 to +55
-25 to +40
Electr. connection
Current draw
M2E 068-CA
Power input
D2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PA plastic, red-brown
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted via support plate
– Bearings: Maintenance-free ball bearings
—
subject to alterations
2
[Pa]
A
1,2
300
[in H O]
Curves
2
250
0,8
p4
Ste
200
4
150
p3
Ste
1
6
0,4
100
p
Ste
2
3
Ste
8
50
p1
5
7
0
100
100
160
200
200
300
300
400
[CFM]
500
[m3/h]
50 Hz
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1635
113
0.49
55
A
2
2115
104
0.45
58
A
3
1210
72
0.36
48
A
4
1740
66
0.35
53
A
5
925
58
0.31
40
A
6
1355
55
0.30
47
A
7
660
48
0.27
31
A
8
960
46
0.26
38
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE
D2E 146-KA45 -01
2.5
EC centrifugal, backward for clean rooms
kg
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
161
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
665
390
1250
1950
160
170
0.70
0.75
4.0 /400
4.0 /400
53
58
0
200
1~ 230
1~ 230
A
-25 to +50
-25 to +40
Electr. connection
Current draw
M2E 068-CF
Power input
D2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PA plastic, red-brown
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted via support plate
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
400
Ste
p4
300
St
ep
ep
St
0,8
2
4
Ste
p1
150
6
1
0,4
100
3
50
8
5
7
0
100
100
200
200
300
300
400
500
[CFM]
600
50 Hz
162
I
[A]
LpA
[dB(A)]
A
1
1675
151
0.66
59
A
2
2185
136
0.60
62
A
3
1230
101
0.50
50
A
4
1800
92
0.47
55
A
5
950
85
0.43
43
A
6
1440
80
0.42
49
A
7
660
71
0.37
31
A
8
960
68
0.36
38
2
3
250
200
P1
[W]
1,2
350
n
[rpm]
[m3/h]
60 Hz
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE
D2E 146-KB27 -01
2.7
EC centrifugal, backward for clean rooms
kg
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
163
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
630
415
1100
1600
150
160
0.66
0.71
4.0 /400
4.0 /400
51
55
0
150
1~ 230
1~ 230
A
-25 to +50
-25 to +45
Electr. connection
Current draw
M2E 068-CF
Power input
D2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
400
300
1,0
2
St
200
4
ep
4
p3
0,5
Ste
6
100
1
p
Ste
St
2
8
ep
3
1
5
7
0
100
100
200
200
300
300
400
500
50 Hz
164
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1490
143
0.62
51
A
2
2005
133
0.59
55
A
3
1110
98
0.49
47
A
4
1635
92
0.47
49
A
5
890
81
0.42
37
A
6
1315
77
0.42
43
A
7
680
69
0.38
31
A
8
990
67
0.37
35
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE, CCC, GOST
D2E 146-HR93 -03
3.0
EC centrifugal, backward for clean rooms
kg
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
165
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
755
580
1350
1750
195
215
0.86
0.94
5.0 /400
5.0 /400
57
54
0
150
1~ 230
1~ 230
A
-25 to +55
-25 to +40
Electr. connection
Current draw
M2E 068-DF
Power input
D2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
Step 4
400
Ste
1,5
p3
1,0
4
Step
200
2
Step
0,5
1
1
6
100
8
3
5
7
0
100
200
200
300
400
400
600
50 Hz
166
[CFM]
[m3/h]
60 Hz
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1790
185
0.81
56
A
2
2290
164
0.72
59
A
3
1210
125
0.60
45
A
4
1820
112
0.57
52
A
5
910
106
0.52
38
A
6
1415
100
0.50
45
A
7
710
94
0.47
30
A
8
1055
91
0.46
38
2
300
n
[rpm]
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE, GOST
3.5
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
167
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
D2E 146-HS97 -03
kg
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
1060
875
1850
2100
355
400
1.55
1.75
8.0 /450
8.0 /450
66
63
0
200
1~ 230
1~ 230
A
-25 to +50
-25 to +55
Electr. connection
Current draw
M2E 068-EC
Power input
D2E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
500
Step 4
Step
3
400
1,5
St
ep
1
2
4
1,0
300
6
200
0,5
1
8
3
100
5
7
0
150
200
300
400
450
600
[CFM]
800
[m3/h]
50 Hz
168
60 Hz
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
2075
328
1.42
66
A
2
2430
269
1.17
61
A
3
1770
268
1.20
61
A
4
2230
222
1.04
62
A
5
1375
225
1.03
54
A
6
1885
197
0.94
57
A
7
1000
192
0.88
45
A
8
1415
180
0.84
49
Ste
p2
n
[rpm]
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: VDE
D2E 146-HT67 -02
3.6
EC centrifugal, backward for clean rooms
kg
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
1
2
red
3
grey
black
blue
green/yellow
6
PE
5
1
2
3
N
4
Speed
increase
4
5
6
L1
169
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
6
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
Accessories
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 160
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
400
1170
110
0.49
2.5 /400
53
100
1~ 230
A
-25 to +55
Electr. connection
Current draw
M2E 068-BF
Power input
D2E 160
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
400
300
1,0
2
St
200
ep
3
Ste
p2
0,5
4
Step
1
1
6
100
3
8
5
7
0
50
100
100
150
200
200
300
250
400
50 Hz
170
[CFM]
[m3/h]
60 Hz
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1210
108
0.47
51
A
2
1735
102
0.44
55
A
3
910
74
0.35
43
A
4
1345
71
0.34
48
A
5
765
64
0.31
38
A
6
1135
61
0.30
44
A
7
555
50
0.26
30
A
8
835
49
0.25
36
Ste
p4
n
[rpm]
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: CCC, GOST
D2E 160-FI01 -01
2.5
EC centrifugal, backward for clean rooms
kg
1
2
3
4
5
6
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
3
2 1
red
grey
black
blue
green/yellow 6 5 4
Electrical connection:
When changing speeds,
switch must break the
circuit
6
PE
5
1
2
3
N
4
Speed
increase
L1
171
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
Technology
Accessories
5x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 160
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
550
1400
180
0.80
4.0 /400
59
150
1~ 230
A
-25 to +40
Electr. connection
Current draw
M2E 068-CF
Power input
D2E 160
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
—
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
Ste
1,5
2
300
St
3
1,0
ep
200
St
ep
4
2
0,5
1
Ste
100
6
p1
3
8
5
7
0
100
100
200
200
300
300
400
500
50 Hz
172
[CFM]
[m3/h]
60 Hz
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1400
180
0.80
59
A
2
1920
162
0.70
60
A
3
1010
120
0.56
48
A
4
1450
113
0.53
52
A
5
770
96
0.46
40
A
6
1115
93
0.45
44
A
7
500
76
0.38
28
A
8
740
75
0.37
34
p4
400
n
[rpm]
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-2-31, CE
Approvals: CCC, GOST
D2E 160-FK11 -02
3.0
EC centrifugal, backward for clean rooms
kg
1
2
3
4
5
6
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4 (max.)
N
Protective earth
white
3
2 1
red
grey
black
blue
green/yellow 6 5 4
Electrical connection:
When changing speeds,
switch must break the
circuit
6
PE
5
1
2
3
N
4
Speed
increase
L1
173
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
Technology
Accessories
5x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
60
565
510
780
710
65
68
0.29
0.30
2.0 /400
2.0 /400
46
42
0
0
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
1~ 230
1~ 230
A
-25 to +50
-25 to +40
Electr. connection
Current draw
M4E 068-CF
Power input
D4E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller: PA plastic, black
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on cable exit
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 5-step blower with integrated terminal box,
EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
—
subject to alterations
A
2
[Pa]
120
[in H O]
Curves
Step 5
100
0,4
Step
4
Ste
p3
2
St
ep
2
80
0,3
4
6
0,2
60
1
ep
St
1
40
0,1
8
20
3
5
10
7
9
0
100
100
174
200
200
300
300
400
[CFM]
500
[m3/h]
50 Hz
60 Hz
A
1
1080
58
0.25
45
A
2
1345
43
0.19
46
A
3
695
52
0.23
33
A
4
1210
39
0.18
43
A
5
560
48
0.22
26
A
6
1080
40
0.19
39
A
7
450
20
0.16
21
A
8
735
20
0.16
29
A
9
315
13
0.13
17
A
10
475
13
0.13
20
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-1, CE
D4E 146-LV19 -14
2.5
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
forward
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
Accessories
X
EC-SYSTEMS
4x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
=
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4
Step 5 (max.)
N
Protective earth
7
8
9
9
8
1
2
3
4
5
PE
N
Speed
increase
6
4
5
1
2
L1
3
175
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
8
9
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 927 231-3
7 x plug pin: AMP 926 886-1
AC centrifugal blowers
dual inlet, Ø 146
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
50
1180
750
85
0.38
2.5 /450
47
0
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
1~ 230
A
-25 to +50
Electr. connection
Current draw
M4E 068-DF
Power input
K4E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: PP plastic, black
Impeller / motor suspension: PA plastic, black
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on cable exit
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 5-step dual blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
—
subject to alterations
2
[Pa]
100
A
0,4
120
[in H O]
Curves
Ste
p5
2
0,3
80
1
1050
76
0.33
45
A
2
1240
65
0.28
46
A
3
810
59
0.27
39
A
4
1060
51
0.24
41
A
5
570
47
0.22
29
A
6
820
43
0.21
35
A
7
400
13
0.15
25
A
8
580
13
0.15
28
A
9
330
10
0.13
25
A
10
480
10
0.13
26
p
e
St
A
4
60
4
p3
0,2
Ste
1
ep
St
40
2
6
e
St
3
0,1
p1
20
8
5
10
9
0
200
200
176
7
400
400
600
800
600
[CFM]
1000
[m3/h]
50 Hz
60 Hz
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Connection leads: Via plug
Protection class: I
Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
K4E 146-AB73 -21
4.0
EC centrifugal, backward for clean rooms
kg
EC-SYSTEMS
EC centrifugal,
forward
Dual centrifugal
blower with flange
EC centrifugal,
backward
Mass of dual
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
X
=
=
=
=
=
=
=
Step 1 (min.)
Step 2
Step 3
Step 4
Step 5 (max.)
N
Protective earth
3
2
1
9
8
1
2
3
4
5
PE
N
Speed
increase
4
6
5
9
8
L1
7
177
Guard grille
p. 556
Connection lead
p. 558
Capacitor
p. 560 f.
Contacts
1
2
3
4
5
8
9
Electrical connection:
When changing speeds,
switch must break the
circuit
Technology
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 927 231-3
7 x plug pin: AMP 926 886-1
Accessories
8x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
AC centrifugal blowers
dual inlet, Ø 097
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
230
230
50
60
50
60
50
60
180
170
300
280
435
410
1550
1450
1350
1250
1950
1850
28
32
50
55
87
100
0.13
0.15
0.23
0.25
0.39
0.45
1.0 /400
1.0 /400
1.5 /400
1.5 /400
2.0 /400
2.0 /400
46
44
50
48
58
57
0
0
0
0
0
0
n
[rpm]
P1
[W]
I
[A]
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D2E 097
M2E 052-BF
A
D2E 097
M2E 052-BF
B
D2E 097
M2E 052-CA
C
1~
1~
1~
1~
1~
1~
-25 to +85
-25 to +80
-25 to +70
-25 to +55
-25 to +40
-25 to +35
subject to alterations
2
[Pa]
[in H O]
Curves
200
C
0,75
250
1,0
300
150
0,5
2
100
2
2
0,25
B
50
1
A
1
0
50
100
1
100
150
200
200
[CFM]
300
400
50 Hz
178
[m3/h]
60 Hz
A
1
1670
27
0.13
A
2
2080
25
0.12
B
1
1490
48
0.22
B
2
2000
44
0.20
C
1
2150
83
0.37
C
2
2475
73
0.33
A1)
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: C CCC, GOST
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
Centrifugal blower
with flange
kg
D2E 097-CH85 -02
D2E 097-CH85 -48
1.5
140.0 128.0
D2E 097-BK66 -02
D2E 097-BK66 -48
D2E 097-BI56 -02
D2E 097-BI56 -48
A
B
C
D
E
H
I
K
78.0
66.0
46.0
80.0 108.0 144.0
1.5
180.0 168.0 100.0
88.0
67.0
1.5
180.0 168.0 100.0
88.0
67.0
L
M
N
O
P
76.0 137.0
62.0
96.0
51.0
79.5 146.0 162.0
86.0 165.0
68.0 114.0
62.5
79.5 146.0 162.0
86.0 165.0
68.0 114.0
62.5
EC centrifugal, backward for clean rooms
Dimensions
Centrifugal blower
without flange
A
B
L
1
5,5
E
N
ØH
M
P
EC-SYSTEMS
O
C
D
EC centrifugal,
forward
K
Accessories
I
Technology
Brass lead tips
179
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
200
AC centrifugal blowers
dual inlet, Ø 133
Perm. amb. temp.
Electr. connection
B
Min. back pressure
M2E 068-DF
Sound pressure level
D2E 133
1~
1~
1~
1~
Capacitor
A
Current draw
M2E 068-CF
Power input
D2E 133
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: A Counter-clockwise, B clockwise seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
700
500
685
510
1700
2100
1500
1800
175
190
190
200
0.77
0.84
0.84
0.88
4.0 /400
4.0 /400
3.0 /450
3.0 /450
58
58
59
56
50
200
0
100
-25 to +40
-25 to +40
-25 to +45
-25 to +40
subject to alterations
2
[Pa]
[in H O]
Curves
500
1,5
400
300
2
2
1,0
A
B
1
0,5
200
100
1
0
100
200
200
300
400
[CFM]
600
50 Hz
180
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2135
160
0.70
A
2
2450
138
0.61
B
1
1885
180
0.80
B
2
2640
130
0.58
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, B also GOST
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
Centrifugal blower
with flange
kg
D2E 133-CI33 -56
D2E 133-CI33 -22
3.3
206.0 190.0 142.0 126.0 102.0 168.0 400.0 204.0
D2E 133-AM47 -01
D2E 133-AM47 -23
3.5
254.0 238.0 108.0
A
B
C
D
92.0
E
I
J
K
69.0 215.0 300.0 171.5
L
M
N
P
97.0 213.0
93.5
67.5
88.0 180.0
79.0
66.0
EC centrifugal, backward for clean rooms
Dimensions
Centrifugal blower
without flange
A
B
L
1
5,5
E
N
M
Ø112
P
EC-SYSTEMS
145
C
D
EC centrifugal,
forward
K
Accessories
I
Technology
Brass lead tips
181
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
J
AC centrifugal blowers
dual inlet, Ø 133
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M2E 068-DF
Power input
D2E 133
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
810
600
1150
1550
190
195
0.84
0.85
3.0 /450
3.0 /450
56
55
0
100
1~ 230
1~ 230
A
-25 to +40
-25 to +40
subject to alterations
2
[Pa]
[in H O]
Curves
500
1,5
400
2
1,0
300
A
0,5
200
100
1
0
100
200
200
300
400
400
[CFM]
600
800
50 Hz
182
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1700
180
0.80
A
2
2480
138
0.61
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
D2E 133-DM47 -01
D2E 133-DM47 -23
4.4
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
270
254
97
1
EC-SYSTEMS
98
213
145
Ø112
67,5
5,5
102
142
126
EC centrifugal,
forward
204
232
Accessories
300
Technology
Brass lead tips
183
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 133
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M4E 068-BF
Power input
D4E 133
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: PA plastic
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
510
540
1180
1240
70
80
0.32
0.35
2.0 /400
2.0 /400
52
54
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +40
-25 to +40
subject to alterations
2
[Pa]
[in H O]
Curves
140
100
0,4
120
80
2
60
0,2
A
40
1
20
0
100
100
200
200
300
300
400
500
50 Hz
184
[CFM]
[m3/h]
60 Hz
A
1
1240
66
0.30
A
2
1380
63
0.29
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
D4E 133-AH01 -55
D4E 133-AH01 -58
2.6
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
254
238
88
1
5,5
76
Ø112
180
66
EC-SYSTEMS
145
69
108
92
EC centrifugal,
forward
171,5
215
Accessories
300
Technology
Brass lead tips
185
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 133
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
670
675
760
790
1080
1100
1230
1280
73
83
75
95
0.33
0.37
0.34
0.43
2.0 /400
2.0 /400
2.0 /450
2.0 /450
52
52
55
56
0
0
0
0
n
[rpm]
P1
[W]
I
[A]
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: PA plastic
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D4E 133
M4E 068-BF
A
D4E 133
M4E 068-CF
B
1~
1~
1~
1~
-25 to +40
-25 to +40
-25 to +70
-25 to +60
subject to alterations
2
[Pa]
[in H O]
Curves
0,6
160
0,4
120
80
2
0,2
2
A
B
40
1
0
100
200
200
300
400
1
400
[CFM]
600
[m3/h]
50 Hz
186
60 Hz
A
1
1150
69
0.31
A
2
1300
65
0.30
B
1
1280
67
0.30
B
2
1370
58
0.27
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
kg
D4E 133-DH01 -J2
D4E 133-DH01 -J4
3.3
D4E 133-DL01 -H9
D4E 133-DL01 -J5
3.8
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
270
254
97
1
EC-SYSTEMS
98
213
145
Ø112
67,5
5,5
102
142
126
EC centrifugal,
forward
204
232
Accessories
300
Technology
Brass lead tips
187
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
935
690
970
690
1650
2100
2050
2550
245
270
300
330
1.08
1.20
1.31
1.45
6.0 /400
6.0 /400
8.0 /400
8.0/400
60
62
63
68
100
250
200
400
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D2E 146
M2E 068-EC
A
D2E 146
M2E 068-EC
B
1~
1~
1~
1~
-25 to +40
-25 to +40
-25 to +40
-25 to +35
subject to alterations
2
2,5
[Pa]
[in H O]
Curves
500
2,0
600
400
B
2
1,5
2
300
1
1,0
A
1
0,5
200
100
0
100
200
200
300
400
400
600
500
800
600
[CFM]
1000
[m3/h]
50 Hz
188
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1935
230
1.02
A
2
2560
167
0.74
B
1
2300
262
1.15
B
2
2600
206
0.91
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
kg
D2E 146-AP43 -02
D2E 146-AP43 -22
4.2
D2E 146-AP47 -02
D2E 146-AP47 -22
4.2
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
270
254
97
1
98
Ø117
219
69
EC-SYSTEMS
145
5,5
102
142
126
EC centrifugal,
forward
206
232
Accessories
350
Technology
Brass lead tips
189
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 146
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M4E 068-CF
Power input
D4E 146
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
835
765
1000
950
100
116
0.44
0.51
2.0 /450
2.0 /450
55
53
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +50
-25 to +50
subject to alterations
0,6
160
120
0,4
2
A
0,2
80
40
1
0
100
200
200
300
400
400
[CFM]
600
800
50 Hz
190
A
1
1180
88
0.39
A
2
1390
65
0.29
2
[Pa]
[in H O]
Curves
[m3/h]
60 Hz
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
D4E 146-AA07 -02
D4E 146-AA07 -22
3.5
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
270
254
97
1
98
Ø117
219
69
EC-SYSTEMS
145
5,5
102
142
126
EC centrifugal,
forward
206
232
Accessories
350
Technology
Brass lead tips
191
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 160
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
M4E 068-DF
Power input
D4E 160
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
60
780
820
1200
1200
117
140
0.51
0.62
3.0 /450
3.0 /450
58
58
0
0
n
[rpm]
P1
[W]
I
[A]
1~ 230
1~ 230
A
-25 to +55
-25 to +40
subject to alterations
2
[Pa]
200
0,8
240
[in H O]
Curves
0,6
160
2
120
0,4
A
0,2
80
40
1
0
100
200
200
300
400
400
[CFM]
600
[m3/h]
50 Hz
192
60 Hz
A
1
1230
114
0.50
A
2
1360
93
0.41
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
kg
D4E 160-DA01 -02
D4E 160-DA01 -22
4.3
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
214
198
103
1
5,5
100,5
Ø130
242
87
EC-SYSTEMS
175
105
145
129
EC centrifugal,
forward
226
176
Accessories
400
Technology
Brass lead tips
193
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 160
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
50
1195
1850
410
1.80
10.0 /400
64
200
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D2E 160
M2E 074-FA
1~ 230
A
-25 to +40
subject to alterations
2
2,5
[Pa]
[in H O]
Curves
600
500
2,0
2
A
1,5
400
1
1,0
300
0,5
200
100
0
150
200
300
400
450
600
800
600
1000
[CFM]
1200
50 Hz
194
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
2265
380
1.67
A
2
2520
338
1.50
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, GOST
Centrifugal blower
with flange
kg
D2E 160-AB01 -06
—
5.7
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
EC centrifugal,
forward
225
276
Technology
Brass lead tips
195
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
1300
Accessories
100,5
Ø130
241
87
EC-SYSTEMS
107
17
5
102
AC centrifugal blowers
dual inlet, Ø 160
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1240
1250
1310
1410
1300
1350
1350
1450
180
245
185
270
0.79
1.07
0.81
1.18
5.0 /400
5.0 /400
6.0 /400
6.0 /400
63
64
64
67
0
10
0
0
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D4E 160
M4E 068-EC
A
D4E 160
M4E 068-GA
B
1~
1~
1~
1~
-25 to +65
-25 to +30
-25 to +70
-25 to +40
subject to alterations
[Pa]
2
1,0
250
[in H O]
Curves
0,75
200
150
0,5
2
100
0,25
A
50
11
B
0
200
400
400
600
800
800
1200
50 Hz
196
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1355
153
0.67
A
2
1445
100
0.43
B
1
1400
154
0.68
B
2
1460
103
0.46
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: B CCC, GOST
Options: With flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
Centrifugal blower
with flange
kg
I
D4E 160-EG06 -05
—
4.5
232.0
D4E 160-FH12 -05
—
5.9
276.0
EC centrifugal, backward for clean rooms
Dimensions
Centrifugal blower
without flange
EC centrifugal,
forward
225
I
Technology
Brass lead tips
197
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
400
Accessories
100,5
Ø130
241
87
EC-SYSTEMS
107
17
5
102
AC centrifugal blowers
dual inlet, Ø 180
subject to alterations
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Current draw
M4D 068-GA
Power input
D4D 180 (1)(2)
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
3~ 230/400 50
3~ 230/400 60
1880
1860
1050
1030
(1) data collected via exhaust duct (step diffuser, 1 m length)
290 0.92/0.53
360 1.04/0.60
—
—
2
[Pa]
[in H O]
1,25
200
A
0,75
250
1,00
300
2
0,50
150
0,25
100
50
1
0
200
400
198
400
600
800
800
1200
1000
1600
1200
[CFM]
2000
[m3/h]
50 Hz
60 Hz
0
0
-25 to +55
-25 to +30
n
[rpm]
P1
[W]
I
[A]
(2) 230 VAC ∆ / 400 VAC Y
Curves
350
62
62
A
1
1100
260
0.83/0.48
A
2
1275
175
0.56/0.32
C1)/C2)
General
information
AC centrifugal,
backward
Motor protection: Without thermal protection
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Radial blower
with flange (large)
kg
—
D4D 180-CB01 -02
9.5
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
7
133
EC centrifugal,
forward
309
255
180
296
136
224
180
Accessories
2
19
600
Brass lead tips
255
Technology
3,2
199
Guard grille
p. 555
Electr. connections
p. 596 f.
Contacts
333
˚
Ø149
60
EC-SYSTEMS
289
6x
278
258
5˚
AC centrifugal blowers
dual inlet, Ø 180
Electr. connection
subject to alterations
Perm. amb. temp.
B
Min. back pressure
M4E 068-LA
Sound pressure level
D4E 180 (1)
1~
1~
1~
1~
Capacitor
A
Current draw
M4E 068-LA
Power input
D4E 180
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1900
2040
2110
2125
1300
1360
1250
1280
360
460
380
495
1.58
2.02
1.68
2.16
10.0 /400
10.0 /400
10.0 /400
10.0 /400
65
66
64
64
0
0
0
0
n
[rpm]
P1
[W]
I
[A]
(1) data collected via exhaust duct (step diffuser, length 1 m)
2
[Pa]
[in H O]
Curves
1,25
350
300
200
1,00
B
0,75
250
2
2
0,50
150
A
0,25
100
50
1
0
200
400
200
-25 to +65
-25 to +40
-25 to +60
-25 to +35
400
600
800
800
1200
1000
1600
1
1200
[CFM]
2000
[m3/h]
50 Hz
60 Hz
A
1
1350
310
1.36
A
2
1400
240
1.07
B
1
1300
360
1.60
B
2
1385
270
1.20
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC, A also GOST
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4E 180-BA02 -02
—
11.0
188.0 168.0 134.0
—
D4E 180-CA02 -02
10.8
278.0 258.0 224.0 180.0
D
296
B
S
90.0
309
255
180
Hole with large
flange only
7
133
E
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
E
S
136
Accessories
2
19
600
Brass lead tips
255
Technology
3,2
Ø 149
333
˚
201
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
60
EC-SYSTEMS
289
6x
C
D
5˚
AC centrifugal blowers
dual inlet, Ø 200
Frequency
Air flow
Speed/rpm
Power input
Current draw
Capacitor
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
3~ 230/400 50
2550
1080
480 1.54/0.89
1~ 230
1~ 230
2380
2050
1100
1250
490
525
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D4D 200 (1)(2)
M4D 068-LA
D4E 200 (1)
A
M4E 068-LA
B
subject to alterations
50
60
(1) data collected via exhaust duct (step diffuser, 1 m length)
2.15
2.30
—
10.0 /400
10.0 /400
2
[Pa]
[in H O]
1,5
350
300
B
1,0
250
2
200
2
0,5
150
A
100
1
50
1
0
250
400
500
800
750
1200
1000
1600
1250
2000
[CFM]
2400
50 Hz
202
[m3/h]
60 Hz
0
-25 to +30
60
60
50
150
-25 to +40
-25 to +40
(2) 230 VAC ∆ / 400 VAC Y
Curves
400
63
n
[rpm]
P1
[W]
I
[A]
A
1
1125
425
1.36/0.79
A
2
1260
310
1.00/0.58
B
1
1185
445
1.95
B
2
1300
350
1.55
C1)/C2)
A1)
General
information
AC centrifugal,
backward
Motor protection: A without TOP, B TOP wired internally
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal blower
with flange (large)
kg
—
D4D 200-CA01 -02
12.0
—
D4E 200-CA02 -02
11.9
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
7
146
EC centrifugal,
forward
341
287
180
327
151
250
180
Accessories
3
21
600
Brass lead tips
287
Technology
3,2
203
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
371
˚
Ø 167
60
EC-SYSTEMS
321
6x
304
284
5˚
AC centrifugal blowers
dual inlet, Ø 225
m3/h
rpm
W
A
D4D 225(1)(2)
M4D 074-LA
subject to alterations
A
3~ 230/400 50
3~ 230/400 60
2980
2430
1000
1050
(1) data collected via exhaust duct (step diffuser, 1 m length)
680 1.99/1.15
700 2.17/1.25
Electr. connection
Current draw
Hz
Perm. amb. temp.
Power input
Motor
Min. back pressure
Speed/rpm
Type
Sound pressure level
Air flow
Nominal data
Capacitor
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
µF/VDB
dB(A)
Pa
°C
p. 596 f.
64
62
0
100
—
—
(2) 230 VAC ∆ / 400 VAC Y
2
[Pa]
[in H O]
Curves
500
1,5
400
A
300
1,0
2
0,5
200
100
1
0
500
500
1000
1000
1500
1500
2000
2500
[CFM]
3000
50 Hz
204
[m3/h]
60 Hz
-25 to +45
-25 to +35
n
[rpm]
P1
[W]
I
[A]
A
1
1110
600
1.75/1.02
A
2
1300
385
1.13/0.66
C1)/C2)
General
information
AC centrifugal,
backward
Motor protection: Without thermal protection
Cable exit: Variable
Protection class: I
Product conforming to standards: EN 60335-1, CE
Approvals: CCC
Centrifugal blower
with flange (large)
kg
—
D4D 225-CC01 -02
12.5
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
7
158
EC centrifugal,
forward
341
287
180
327
Accessories
151
600
Brass lead tips
287
Technology
2
24
205
Guard grille
p. 555
Electr. connections
p. 596 f.
Contacts
3,2
Ø194
370
˚
250
180
60
EC-SYSTEMS
321
6x
304
284
5˚
AC centrifugal blowers
dual inlet, Ø 225
subject to alterations
Electr. connection
C
Perm. amb. temp.
M6E 068-LA
Min. back pressure
D6E 225 (1)
B
Sound pressure level
M4E 074-LA
Capacitor
D4E 225 (1)
A
Current draw
M4E 074-LA
Power input
D4E 225
Speed/rpm
Motor
Air flow
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: A B IP 22, C IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
p. 596 f.
1~ 230
50
2600
1100
700
3.05
25.0 /400
67
20
-25 to +40
1~ 230
50
2650
1150
650
2.84
25.0 /400
65
100
-25 to +40
1~ 230
1~ 230
50
60
2680
2480
800
900
365
410
1.60
1.80
10.0 /450
10.0 /450
59
59
20
80
-25 to +40
-25 to +40
(1) data collected via exhaust duct (step diffuser, length 1 m)
2
[Pa]
[in H O]
Curves
350
300
1,0
250
2
2
B
A
200
150
2
1
0,5
C
100
1
1
50
0
500
500
206
1000
1000
1500
1500
2000
[CFM]
2500
[m3/h]
50 Hz
60 Hz
n
[rpm]
P1
[W]
I
[A]
A
1
1200
660
2.88
A
2
1370
480
2.13
B
1
1170
680
2.98
B
2
1300
550
2.44
C
1
850
330
1.45
C
2
940
245
1.08
A1)
A1)
A1)
General
information
AC centrifugal,
backward
Motor protection: TOP wired internally
Cable exit: Variable
Protection class: I
Capacitor: A B FPU (P2) acc. to IEC 252
Product conforming to standards: EN 60335-1, CE
Approvals: A B CCC, B GOST
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4E 225-BC01 -02
—
12.1
341.0 321.0 200.0 180.0 146.0 287.0 287.0
—
D4E 225-CC01 -02
12.4
341.0 321.0 304.0 284.0 250.0 287.0 287.0 180.0
—
D6E 225-FB07 -02
12.5
387.0 367.0 304.0 284.0 250.0 333.0 333.0 180.0
B
327
B
C
D
E
F
I
S
90.0
A
F
180
Hole with large
flange only
7
158
C
EC centrifugal, backward for clean rooms
A
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
E
S
151
Accessories
2
24
600
Brass lead tips
I
Technology
3,2
Ø194
370
˚
207
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
60
EC-SYSTEMS
B
6x
C
D
5˚
AC centrifugal blowers
dual inlet, Ø 225
B
subject to alterations
Electr. connection
M4D 094-LA
Perm. amb. temp.
D4D 225 (2)
3~
3~
3~
3~
Min. back pressure
A
Capacitor
M4D 094-LA
Max. current
draw (1)
D4D 225
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
400 Y
400 Y
400 Y
400 Y
50
60
50
60
1300
1350
1230
1360
950
1320
1140
1280
1.82
2.40
2.10
2.30
(1) Nominal data in operating point with maximum load
—
—
—
—
0
0
0
150
-40 to +85
-40 to +40
-40 to +70
-40 to +50
2
[Pa]
[in H O]
1,5
400
B
300
2
1,0
2
200
1
0,5
1
100
A
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
208
[CFM]
[m3/h]
60 Hz
D1)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
D1)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1360
717
1.50
69
A
2
1420
454
1.18
63
B
1
1320
877
1.70
72
B
2
1390
589
1.31
65
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: A GOST
Options: 400 VAC ∆/Y for two speed steps available on request,
mounting brackets on request
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4D 225-FH02 -01
—
15.6
200.0 180.0 146.0
—
D4D 225-GH02 -01
15.6
304.0 284.0 250.0 180.0
D
327
E
B
90.0
387
333
180
Hole with large
flange only
7
158
S
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
E
S
151
Accessories
2
24
600
Brass lead tips
333
Technology
3,2
Ø194
370
˚
209
Guard grille
p. 555
Electr. connections
p. 596 f.
Contacts
60
EC-SYSTEMS
367
6x
C
D
5˚
AC centrifugal blowers
dual inlet, Ø 225
B
subject to alterations
Electr. connection
M4E 094-LA
Perm. amb. temp.
D4E 225 (2)
1~
1~
1~
1~
Min. back pressure
A
Capacitor
M4E 094-LA
Max. current
draw (1)
D4E 225
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1230
1410
1230
1370
1060
1085
1060
1120
5.38
5.24
5.38
5.40
10.0 /450
10.0 /500
10.0 /450
10.0 /500
0
200
100
250
(1) Nominal data in operating point with maximum load
-40 to +55
-40 to +45
-40 to +55
-40 to +45
2
[Pa]
[in H O]
1,5
400
300
2
2
1,0
B
200
A
1
0,5
1
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
210
[CFM]
[m3/h]
60 Hz
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
A2a)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1330
802
4.16
69
A
2
1410
530
3.08
63
B
1
1270
947
4.81
71
B
2
1380
652
3.52
65
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: A GOST
Options: Mounting brackets on request
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4E 225-EH01 -01
—
16.7
200.0 180.0 146.0
—
D4E 225-DH01 -01
16.7
304.0 284.0 250.0 180.0
D
327
E
B
90.0
387
333
180
Hole with large
flange only
7
158
S
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
E
S
151
Accessories
2
24
600
Brass lead tips
333
Technology
3,2
Ø194
370
˚
211
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
60
EC-SYSTEMS
367
6x
C
D
5˚
AC centrifugal blowers
dual inlet, Ø 240
subject to alterations
Min. back pressure
Perm. amb. temp.
Electr. connection
A
Capacitor
M4E 094-IF
Max. current
draw (1)
D4E 240
Max. power
input (1)
Motor
Speed/rpm (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
50
60
1300
1310
1020
1320
4.45
5.75
25.0 /400
25.0 /400
0
50
1~ 230
1~ 230
-40 to +50
-40 to +55
(1) Nominal data in operating point with maximum load
2
A
2,0
[Pa]
[in H O]
Curves
500
1,5
400
2
1,0
300
200
0,5
1
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
212
A2a)
[CFM]
[m3/h]
60 Hz
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1345
849
3.80
73
A
2
1390
692
3.10
70
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Options: Mounting brackets on request
kg
D4E 240-BA01 -01
—
15.3
EC centrifugal, backward for clean rooms
Centrifugal blower
with flange (large)
90
200
180
Accessories
151
600
Brass lead tips
287
Technology
2
24
Ø209
370
0˚
2
3x1
EC-SYSTEMS
321
5˚
146
7
158
EC centrifugal,
forward
341
287
180
327
213
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
Centrifugal blower
with flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
AC centrifugal blowers
dual inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
400 Y
400 Y
400 Y
400 Y
50
60
50
60
1240
1410
1200
1410
1140
1210
1270
1270
2.10
2.20
2.30
2.20
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D4D 250
M4D 094-LA
A
D4D 250 (2)
M4D 094-LA
B
subject to alterations
3~
3~
3~
3~
(1) Nominal data in operating point with maximum load
—
—
—
—
0
250
50
350
-40 to +60
-40 to +45
-40 to +45
-40 to +45
2
[Pa]
[in H O]
2,0
1,5
400
2
2
B
300
1,0
A
1
1
0,5
200
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
214
[CFM]
[m3/h]
60 Hz
D1)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
D1)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1320
875
1.73
71
A
2
1410
481
1.21
65
B
1
1280
1001
1.89
72
B
2
1370
675
1.43
69
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Options: 400 VAC ∆/Y for two speed steps available on request,
mounting brackets on request
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4D 250-BA02 -01
—
16.7
218.0 190.0 167.0
—
D4D 250-CA02 -01
16.7
313.0 285.0 262.0 180.0 293.0
D
387
E
B
U
90.0 198.0
349
328
298
180
Hole with large
flange only
7
194
S
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
E
Accessories
Ø 200
600
298
Technology
Brass lead tips
215
Guard grille
p. 555
Electr. connections
p. 596 f.
Contacts
173
27
5
3,2
S
C
U
D
392
0˚
EC-SYSTEMS
329
6x6
AC centrifugal blowers
dual inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
1210
1460
1200
1400
1240
1230
1250
1285
6.00
5.54
6.00
5.90
14.0 /500
14.0 /500
14.0 /500
14.0 /500
0
300
100
350
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D4E 250
M4E 094-LA
A
D4E 250 (2)
M4E 094-LA
B
subject to alterations
1~
1~
1~
1~
(1) Nominal data in operating point with maximum load
-40 to +40
-40 to +45
-40 to +40
-40 to +40
2
[Pa]
[in H O]
2,0
1,5
400
B
2
2
300
1,0
A
200
1
0,5
1
100
0
500
1000
1000
1500
2000
2000
3000
2500
4000
50 Hz
216
[CFM]
[m3/h]
60 Hz
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
500
A2a)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
1320
975
4.74
71
A
2
1400
665
3.50
65
B
1
1270
1100
5.31
72
B
2
1370
788
3.94
69
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Approvals: B GOST
Options: Mounting brackets on request
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D4E 250-BA01 -01
—
16.3
218.0 190.0 167.0
—
D4E 250-CA01 -01
16.3
313.0 285.0 262.0 180.0 293.0
D
387
E
B
U
90.0 198.0
349
328
298
180
Hole with large
flange only
7
194
S
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
–
E
Accessories
Ø 200
600
298
Technology
Brass lead tips
217
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
173
27
5
3,2
S
C
U
D
392
0˚
EC-SYSTEMS
329
6x6
AC centrifugal blowers
dual inlet, Ø 250
Frequency
Speed/rpm (1)
Max. power
input (1)
Max. current
draw (1)
Capacitor
Min. back pressure
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
µF/VDB
Pa
°C
p. 596 f.
230
230
230
230
50
60
50
60
800
770
680
580
400
480
470
500
1.85
2.15
2.20
2.30
10.0 /400
10.0 /450
10.0 /400
10.0 /450
0
0
0
0
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D6E 250
M6E 094-HA
A
D6E 250 (2)
M6E 094-HA
B
subject to alterations
1~
1~
1~
1~
(1) Nominal data in operating point with maximum load
-40 to +80
-40 to +80
-40 to +70
-40 to +55
2
[Pa]
[in H O]
1,0
200
0,75
B
2
2
0,5
150
A
100
1
0,25
1
50
0
400
400
800
800
1200
1200
1600
2000
1600
2400
2800
50 Hz
218
[CFM]
[m3/h]
60 Hz
A2a)
(2) Data collected via exhaust duct (step diffuser, 1 m length)
Curves
250
A2a)
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
A
1
890
318
1.51
59
A
2
940
244
1.25
53
B
1
830
375
1.74
65
B
2
900
304
1.45
57
General
information
AC centrifugal,
backward
Motor protection: Design with thermal overload protector
Cable exit: Axial
Protection class: I (acc. to EN 61800-5-1)
Product conforming to standard: CE
Options: Mounting brackets on request
EC centrifugal,
backward
Dimensions
Centrifugal blower
with flange
Centrifugal blower
with flange (large)
kg
D6E 250-BA01 -01
—
14.4
218.0 190.0 167.0
—
D6E 250-CA01 -01
14.4
313.0 285.0 262.0 180.0 293.0
D
387
E
B
U
90.0 198.0
349
328
298
180
Hole with large
flange only
7
194
S
EC centrifugal, backward for clean rooms
C
EC centrifugal,
forward
Mass of
centrifugal blower
AC centrifugal,
forward
–
–
–
–
–
E
Accessories
Ø 200
600
298
Technology
Brass lead tips
219
Guard grille
p. 555
Capacitor
p. 560 f.
Electr. connections
p. 596 f.
Contacts
173
27
5
3,2
S
C
U
D
392
0˚
EC-SYSTEMS
329
6x6
220
General
information
222
EC centrifugal fans with sheet steel impeller, 24 / 48 VDC
Ø 250 - Ø 280
240
EC centrifugal fans with aluminium impeller, 24 / 48 VDC
Ø 310 - Ø 400
246
EC centrifugal fans with plastic impeller, line-fed
Ø 133 - Ø 250
262
EC centrifugal fans with sheet steel impeller, line-fed
Ø 250 - Ø 280
296
EC centrifugal fans with aluminium impeller, line-fed
Ø 310 - Ø 630
316
AC centrifugal,
backward
Ø 120 - Ø 250
221
Contacts
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
EC centrifugal fans with plastic impeller, 24 / 48 VDC
AC centrifugal,
forward
EC centrifugal fans backward curved
EC centrifugal fans
backward curved, Ø 120
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
250
4060
26
1.20
62
-25 to +50
G)
A
48
36-57
250
4060
26
0.60
62
-25 to +50
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 120
M1G 045-BE
R1G 120
M1G 045-BE
subject to alterations
[Pa]
Curves
A
1,5
400
4'
300
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
4520
36
65
—
A
2’
4500
36
64
27
A
3’
4540
36
61
45
A
4’
4750
32
64
39
A
1
4060
26
62
—
A
2
4000
26
61
27
A
3
4050
26
58
45
A
4
4200
23
61
39
A
5
3270
14
56
—
A
6
3250
14
55
27
A
7
3280
14
53
45
A
8
3400
13
56
39
1,0
4
3'
UR
200
3
0,5
8
UN
7
100
2'
2
6
5
0
25
40
222
n
[rpm]
50
80
75
120
100
160
1
125
200
240
1'
[CFM]
General
information
• Tach output
• Reverse polarity and locked-rotor protection
AC centrifugal,
backward
Technical features:
Control input 0-10 VDC / PWM
Cable exit: Axial
Protection class: I
Product conforming to standard: EN 60950-1
Approvals: A (48 VDC) CCC
0.5
96120-2-4013
R1G 120-AD11 -02
0.5
96120-2-4013
54 ±1
45,3 ±0,5
18
Depth of screw
max. 4 mm
M4
47
16
EC centrifugal,
forward
R1G 120-AD13 -02
15
Inlet nozzle
(long)
0,
kg
±
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
–
•
–
–
–
–
17
EC-SYSTEMS
6
60
300 ±20
Ø146
Ø96 -1
Ø 59
Ø 98
Ø 120
Brass lead tips
4x90˚
Technology
Accessories
2
223
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
26
40,5
EC centrifugal fans
backward curved, Ø 133
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
360
3900
28
1.30
63
-25 to +60
G)
A
48
36-57
360
3900
28
0.70
63
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 133
M1G 055-BD
R1G 133
M1G 055-BD
subject to alterations
2
[Pa]
[in H O]
Curves
A
500
1,5
400
UR
4'
UN
300
4
1,0
3'
200
7
0,5
12
2'
2
11
100
6
10
9
0
50
100
100
224
5
150
200
1
200
300
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
4450
39
74
—
A
2’
4250
44
60
45
A
3’
4270
44
59
56
A
4’
4380
41
61
44
A
1
3900
28
63
—
A
2
3770
31
58
45
A
3
3770
31
56
56
A
4
3850
29
58
44
A
5
3500
20
59
—
A
6
3380
23
55
45
A
7
3400
23
53
56
A
8
3450
21
55
44
A
9
2970
13
55
—
A
10
2860
15
51
45
A
11
2880
15
49
56
A
12
2930
14
51
44
8
3
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 133-AA17 -02
0.7
09566-2-4013
R1G 133-AA65 -02
0.7
09566-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
91±1
Ø 58 ±0,15
13
8
EC centrifugal,
forward
55,3 ±0,6
EC-SYSTEMS
29
Ø129
6
85
450 +20
M4
Depth of screw
max. 6 mm
Accessories
2
Technology
41
60,6
225
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
Ø 87
Ø133
Ø72
Ø92,8
Brass lead tips
EC centrifugal fans
backward curved, Ø 175
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
565
3100
34
1.60
65
-25 to +60
G)
A
48
36-57
565
3100
34
1.00
65
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 175
M1G 055-BD
R1G 175
M1G 055-BD
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
400
4'
UR
300
4
1,0
UN
3'
3
200
8
0,5
7
2'
12
2
100
11
6
10
9
0
100
100
226
5
200
200
300
1
1'
300
400
500
[CFM]
600
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3390
46
67
—
A
2’
3200
51
60
49
A
3’
3170
51
58
58
A
4’
3300
51
66
39
A
1
3100
34
65
—
A
2
2910
39
58
49
A
3
2880
39
56
58
A
4
3010
37
64
39
A
5
2520
20
60
—
A
6
2430
22
54
51
A
7
2390
23
51
58
A
8
2470
21
60
39
A
9
2050
12
56
—
A
10
1950
13
50
51
A
11
1920
13
56
58
A
12
1990
12
53
40
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 175-AB63 -02
0.7
09576-2-4013
R1G 175-AB41 -02
0.7
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with VDE, CCC
69 ±1
14
58 ±0,15
EC centrifugal,
forward
55,3 ±1
29
6
EC-SYSTEMS
Ø125,5
Ø175
Ø131
Ø72
Ø170
10
Brass lead tips
M4
85
450 ±20
Depth of screw
max. 6 mm
Accessories
2
Technology
62
227
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
42
EC centrifugal fan
backward curved, Ø 175
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M1G 055-CF
Power input
R1G 175
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black, with cooling holes
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-52
695
4000
75
1.75
72
-25 to +40
G)
subject to alterations
2
A
2,5
[Pa]
[in H O]
Curves
2,0
500
4'
4
1,5
400
UN
3'
8
3
1,0
300
200
7
2'
0,5
2
6
100
5
0
100
100
228
200
200
300
1
300
400
500
1'
[CFM]
600
700
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
4250
88
73
—
A
2’
4130
93
71
39
A
3’
4050
96
67
55
A
4’
4130
93
72
43
A
1
4000
75
72
—
A
2
3920
80
69
39
A
3
3880
83
66
55
A
4
3920
80
71
43
A
5
3290
42
67
—
A
6
3250
45
64
39
A
7
3160
47
62
55
A
8
3250
46
66
43
600
U52V
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 175-AF29 -04
1.0
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: CCC
69 ±1
14
58 ±0,15
EC centrifugal,
forward
67 ±1
29
6
EC-SYSTEMS
Ø125,5
Ø175
Ø131
Ø72
Ø170
10
Brass lead tips
M4
85
450 ±20
Depth of screw
max. 6 mm
Accessories
2
Technology
62
229
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
42
EC centrifugal fans
backward curved, Ø 190
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
620
2950
51
2.30
68
-25 to +40
G)
A
48
36-57
620
2950
51
1.20
68
-25 to +40
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: A (24 VDC) IP 20, A (48 VDC) IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 190
M1G 055-CF
R1G 190
M1G 055-CF
subject to alterations
2
[Pa]
500
A
2,0
600
[in H O]
Curves
4'
1,5
400
UR
4
300
3'
1,0
UN
3
8
200
2'
0,5
7
2
100
6
0
100
100
230
5
300
200
200
300
400
500
1
600
1'
400
700
[CFM]
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3300
71
70
—
A
2’
3200
75
66
45
A
3’
3160
77
63
53
A
4’
3290
72
67
42
A
1
2950
51
68
—
A
2
2870
54
63
45
A
3
2830
56
60
53
A
4
2940
51
63
42
A
5
2390
28
62
—
A
6
2340
30
58
45
A
7
2320
31
54
53
A
8
2390
28
58
42
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 190-AB27 -02
1.0
09576-2-4013
R1G 190-AB25 -02
1.0
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
68,5 ±1
Ø58 ±0,15
14
EC centrifugal,
forward
67 ±0,6
EC-SYSTEMS
29
Ø125,5
max. Ø190
min. Ø131
Ø72
Ø170
10
Brass lead tips
6
85
M4
2
Depth of screw
max. 6 mm
Accessories
min. 44,3
Technology
max. 62,8
231
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
450 +20
EC centrifugal fans
backward curved, Ø 190
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
560
3250
80
3.70
68
-25 to +60
G)
A
48
36-57
545
3200
71
1.65
68
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 190
M1G 074-BF
R1G 190
M1G 074-BF
subject to alterations
A
2
[Pa]
[in H O]
Curves (established at 24 VDC)
2,5
700
600
4'
2,0
500
UR
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3580
106
71
—
A
2’
3590
105
66
41
A
3’
3630
103
65
45
A
4’
3770
97
69
33
A
1
3250
80
68
—
A
2
3275
80
64
42
A
3
3300
79
63
45
A
4
3400
74
66
34
A
5
2700
47
65
—
A
6
2710
47
59
41
A
7
2740
45
58
44
A
8
2795
42
61
33
A
9
1910
19
60
—
A
10
1910
20
51
39
A
11
1940
19
49
43
A
12
1985
18
52
33
4
3'
1,5
400
3
UN
8
300
1,0
2'
2
7
200
6
0,5
12
11
100
10
0
50
100
232
100
9
200
150
200
300
5
250
400
1
300
500
1'
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 190-AC37 -52
1.3
09576-2-4013
R1G 190-AC11 -52
1.3
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
68,5 ±1
Ø58 ±0,15
14
EC centrifugal,
forward
65 ±1
EC-SYSTEMS
32,7
Ø125,5
max. Ø190
min. Ø131
Ø92
Ø170
10
Brass lead tips
6
85
M4
2
Depth of screw
max. 6 mm
Accessories
min. 44,6
Technology
max. 62,8
233
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
450 +20
EC centrifugal fans
backward curved, Ø 220
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
1055
3150
106
5.00
76
-25 to +60
G)
A
48
36-57
1015
3100
100
2.40
73
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 220
M1G 074-BF
R1G 220
M1G 074-BF
subject to alterations
A
2
[Pa]
[in H O]
Curves (established at 24 VDC)
3,0
800
700
500
2,0
600
UR
4'
4
3'
300
1,0
3
8
2'
200
2
7
6
100
0
200
200
234
400
400
600
5
800
600
1000
1
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3400
128
78
—
A
2’
3200
132
69
53
A
3’
3050
135
67
55
A
4’
3000
137
71
46
A
1
3150
106
76
—
A
2
3010
110
68
53
A
3
2870
112
65
55
A
4
2800
113
69
46
A
5
2470
50
70
—
A
6
2360
54
63
53
A
7
2300
57
59
55
A
8
2250
59
63
46
UN
400
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 220-AB35 -52
1.4
09609-2-4013
R1G 220-AB73 -52
1.4
09609-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
71±1
Ø58 ±0,15
21
EC centrifugal,
forward
65 ±1
EC-SYSTEMS
32,7
Ø252
Ø155
min. Ø160,7
Ø92
max. Ø220,9
22
Brass lead tips
6
85
M4
2
Depth of screw
max. 6 mm
Accessories
min. 44
Technology
max. 64
235
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
450 +20
EC centrifugal fans
backward curved, Ø 225
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
1125
2600
100
4.60
67
-25 to +60
G)
A
48
36-57
1130
2700
95
2.20
67
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 225
M1G 074-BF
R1G 225
M1G 074-BF
subject to alterations
A
2
[Pa]
[in H O]
Curves (established at 48 VDC)
700
500
2,0
600
4'
4
300
8
3'
1,0
UN
3
200
7
2'
2
6
100
5
0
200
200
236
400
400
600
800
1
1'
600
[CFM]
1000
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2780
112
69
—
A
2’
2610
116
64
48
A
3’
2570
117
62
57
A
4’
2780
112
66
42
A
1
2700
95
67
—
A
2
2450
93
63
48
A
3
2400
94
60
57
A
4
2610
91
64
42
A
5
2230
59
63
—
A
6
2150
63
58
48
A
7
2100
64
56
57
A
8
2230
58
58
42
UR
400
n
[rpm]
General
information
kg
Inlet nozzle
(long)
R1G 225-AF07 -52
1.5
96358-2-4013
R1G 225-AF11 -52
1.5
96358-2-4013
99±1
65±1
Ø58±0,15
28
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
M4
2
EC-SYSTEMS
Depth of screw
max. 6 mm
Accessories
max. 89,4
Technology
min. 62
237
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
450 +20
32,7
Ø146
Ø92
min. Ø153
max. Ø225,3
6
85
Ø223
25
Brass lead tips
EC centrifugal fans
backward curved, Ø 250
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
1140
2540
93
4.30
73
-25 to +60
G)
A
48
36-57
1200
2600
105
2.55
72
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 250
M1G 074-CF
R1G 250
M1G 074-CF
subject to alterations
A
2
[Pa]
[in H O]
Curves (established at 48 VDC)
700
500
2,0
600
400
4
3'
300
8
3
1,0
UN
200
7
2'
2
6
100
0
200
200
238
5
600
400
400
600
800
1000
1
1'
[CFM]
1200
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2870
134
75
—
A
2’
2610
139
68
55
A
3’
2530
140
63
58
A
4’
2650
138
66
48
A
1
2600
105
72
—
A
2
2440
114
66
55
A
3
2360
116
62
58
A
4
2490
112
64
48
A
5
2190
59
68
—
A
6
2020
67
62
55
A
7
2020
70
57
58
A
8
2070
66
59
48
UR
4'
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 250-AQ21 -52
2.0
96359-2-4013
R1G 250-AQ37 -52
2.0
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
EC-SYSTEMS
31
Ø255
Ø164,5
max. Ø250,2
Ø92
min. Ø172
6
85
58 ±0,15
28
75 ±1
Brass lead tips
EC centrifugal,
forward
31
89 ±1
M4
450+20
Depth of screw
max. 6 mm
Accessories
2
Technology
max. 74,3
239
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
min. 44,5
EC centrifugal fan
backward curved, Ø 250
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
1580
2645
135
2.80
72
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: Sheet steel
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 250
M3G 084-CA
A
subject to alterations
A
2
[Pa]
[in H O]
Curves
800
3,0
UR
2,5
700
600
4'
500
2,0
UN
4
1,5
400
3'
3
1,0
300
8
2'
200
7
0,5
2
100
6
12
0
11
10
200
400
240
9
5
400
800
1'
1
600
800
1200
1000
1600
[CFM]
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3055
207
75
—
A
2’
2990
256
70
45
A
3’
2970
274
68
60
A
4’
2980
270
71
55
A
1
2645
135
72
—
A
2
2600
166
67
45
A
3
2580
182
64
60
A
4
2590
177
66
55
A
5
1900
56
66
—
A
6
1875
69
59
45
A
7
1870
73
56
60
A
8
1870
72
58
55
A
9
835
9
48
—
A
10
830
10
44
45
A
11
830
11
43
60
A
12
830
10
35
55
General
information
Inlet nozzle
(long)
R3G 250-AD62 -30
3.0
96359-2-4013
Depth of screw
12-14 mm
106,5 ±1,8
77 ±1
EC centrifugal,
forward
kg
31
±0
90
,1
5
EC-SYSTEMS
34
Ø255
Ø164,5
Ø102
Ø172
Ø252
28
0
+2
0
60
85
M5
8
Accessories
2
Technology
Core-end sleeves
min. 55,7
max. 85,2
241
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
EC centrifugal fans
backward curved, Ø 280
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
1750
1710
95
4.60
71
-25 to +60
G)
A
48
36-57
1750
1710
95
2.30
71
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: Sheet steel
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 280
M1G 074-CF
R1G 280
M1G 074-CF
subject to alterations
A
2
[Pa]
[in H O]
Curves
500
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1840
118
72
—
A
2’
1650
127
64
55
A
3’
1670
126
62
55
A
4’
1950
114
67
31
A
1
1710
95
71
—
A
2
1550
100
63
55
A
3
1560
100
59
55
A
4
1810
91
64
31
A
5
1470
60
67
—
A
6
1360
68
60
55
A
7
1370
67
55
55
A
8
1530
56
59
31
1,5
400
n
[rpm]
4'
UR
300
1,0
4
3'
UN
8
200
3
0,5
7
2'
100
2
6
5
0
200
400
242
400
600
800
800
1200
1
1000
1600
1'
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R1G 280-AE45 -52
2.8
96360-2-4013
R1G 280-AE47 -52
2.8
96360-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
EC-SYSTEMS
31
Ø280
Ø182,5
max. Ø281,5
Ø92
min. Ø190,2
6
85
58 ±0,15
31
75 ±1
Brass lead tips
EC centrifugal,
forward
35
125 ±1
M4
450 +20
Accessories
Depth of screw
max. 6 mm
Technology
2
243
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
min. 79,7
max. 112,5
EC centrifugal fan
backward curved, Ø 280
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-CA
Power input
R3G 280
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet steel
Rotor: Coated in black
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
2020
1965
123
2.60
70
-25 to +60
G)
subject to alterations
2
[Pa]
1,5
400
UN
300
1,0
3
200
8
2
0,5
7
100
6
12
11
10
5
9
400
244
tL
[%]
1’
2265
187
72
—
2’
2185
243
68
53
A
3’
2165
258
65
60
A
4’
2230
213
69
50
A
1
1965
123
70
—
A
2
1905
160
65
53
A
3
1885
171
61
60
A
4
1940
140
66
50
A
5
1390
46
63
—
A
6
1365
61
58
53
A
7
1360
65
53
60
A
8
1380
53
55
50
A
9
800
12
53
—
A
10
790
15
48
53
A
11
785
15
42
60
A
12
795
13
41
50
2'
200
LpA
[dB(A)]
3'
4
0
P1
[W]
A
UR
4'
n
[rpm]
A
A
2,0
500
[in H O]
Curves
400
600
800
800
1200
1000
1600
1
1200
2000
1'
[CFM]
[m3/h]
General
information
Inlet nozzle
(long)
R3G 280-AC66 -30
3.3
96360-2-4013
Depth of screw
12-14 mm
121±1,8
77±1
EC centrifugal,
forward
kg
35
5
,1
±0
90
EC-SYSTEMS
34
Ø280
Ø182,5
Ø191
Ø102
0
Ø281
31
+2
0
60
85
M5
8
2
Accessories
min. 79,7
max. 112,5
Technology
Core-end sleeves
245
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA
EC centrifugal fans
backward curved, 3-D, Ø 310
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
A
24
16-28
1910
1600
90
4.20
64
-25 to +45
G)
A
48
36-57
1910
1600
90
2.20
64
-25 to +45
G)
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R1G 310
M1G 074-CF
R1G 310
M1G 074-CF
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
500
300
1,0
4'
UR
4
3'
200
8
UN
3
0,5
7
2'
100
2
6
0
200
400
246
400
600
800
800
1200
5
1000
1600
1
1'
1200
2000
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1720
113
66
—
A
2’
1540
122
60
62
A
3’
1490
124
59
67
A
4’
1560
121
63
50
A
1
1600
90
64
—
A
2
1430
96
58
62
A
3
1390
99
58
67
A
4
1450
96
61
50
A
5
1150
69
60
—
A
6
1260
65
55
62
A
7
1230
67
54
67
A
8
1270
65
58
50
1,5
400
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R1G 310-AD19 -52
2.6
31050-2-4013
31051-2-4013
R1G 310-AD33 -52
2.6
31050-2-4013
31051-2-4013
Inlet nozzle (long)
120 ±1
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, A (48 VDC) with CCC
Depth of screw
max. 6 mm
EC centrifugal,
forward
48
18
5
,1
±0
31
EC-SYSTEMS
58
M4
Ø300
Ø211
Ø208,1
max. Ø318,5
min. Ø220
Ø92
Brass lead tips
55,5
35
75 ±1
6
4x90˚
85
2
Technology
max. 110,5
247
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
min. 69,5
Accessories
600 +20
EC centrifugal fan
backward curved, 3-D, Ø 310
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M1G 074-CF
Power input
R1G 310
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-52
2100
1800
120
3.00
67
-25 to +40
G)
subject to alterations
2
[Pa]
1,5
400
4'
300
1,0
4
8
UN
3'
200
U52 V
3
0,5
7
100
2
2'
6
5
0
400
400
248
800
800
1200
1600
1
1200
2000
1'
[CFM]
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1895
130
67
—
A
2’
1720
140
64
59
A
3’
1610
147
60
67
A
4’
1635
146
65
48
A
1
1800
120
67
—
A
2
1610
118
62
59
A
3
1530
122
58
67
A
4
1570
120
63
48
A
5
1570
74
63
—
A
6
1430
80
58
59
A
7
1350
82
54
67
A
8
1400
80
60
48
A
2,0
500
[in H O]
Curves (established with long inlet nozzle)
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R1G 310-AD17 -11
2.6
31050-2-4013
31051-2-4013
Inlet nozzle (long)
120 ±1
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
Depth of screw
max. 6 mm
EC centrifugal,
forward
48
18
5
,1
±0
31
EC-SYSTEMS
58
M4
Ø300
Ø211
Ø208,1
max. Ø318,5
min. Ø220
Ø92
Brass lead tips
55,5
35
75 ±1
6
4x90˚
85
2
Technology
max. 110,5
249
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
min. 69,5
Accessories
700 +20
EC centrifugal fan
backward curved, 3-D, Ø 310
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-FA
Power input
R3G 310
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
2230
2000
190
4.00
71
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
3,0
800
2,5
700
4'
600
UR
500
2,0
UN
4
1,0
300
8
2'
200
2
0,5
7
100
12
6
11
10
9
0
600
250
5
400
1
800
1200
1'
[CFM]
1200
1800
2400
[m3/h]
LpA
[dB(A)]
tL
[%]
1’
2395
271
74
—
A
2’
2345
325
71
47
A
3’
2320
362
70
60
A
4’
2330
350
74
54
A
1
2070
178
71
—
A
2
2035
211
67
47
A
3
2015
234
65
60
A
4
2025
227
70
54
A
5
1445
66
61
—
A
6
1430
79
59
47
A
7
1420
88
57
60
A
8
1420
85
62
54
A
9
930
23
50
—
A
10
925
26
48
47
A
11
920
29
47
60
A
12
920
28
51
54
3'
3
P1
[W]
A
1,5
400
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 310-AN12 -30
4.2
31050-2-4013
31051-2-4013
Inlet nozzle (long)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
251
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 310
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-FA
Power input
R3G 310
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
2620
1930
208
4.35
69
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
600
2,4
700
4'
UR
UN
1,8
500
3'
4
400
3
1,2
300
2'
200
0,6
8
100
6
12
11
10
5
9
0
400
800
1000
252
1200
2000
1
1600
1'
2000
3000
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2230
317
72
—
A
2’
2190
373
69
50
A
3’
2150
415
66
66
A
4’
2175
390
67
63
A
1
1930
208
69
—
A
2
1900
248
65
50
A
3
1870
274
62
66
A
4
1890
257
61
63
A
5
1290
69
59
—
A
6
1280
80
57
50
A
7
1270
90
55
66
A
8
1280
85
54
63
A
9
660
14
47
—
A
10
660
15
46
50
A
11
655
17
44
66
A
12
655
16
44
63
2
7
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 310-AL09 -30
4.4
31050-2-4013
31051-2-4013
Inlet nozzle (long)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
253
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
Technology
Accessories
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 355
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-FA
Power input
R3G 355
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
2790
1560
178
3.70
69
-25 to +60
G)
subject to alterations
A
2
[Pa]
2,5 [in H O]
Curves (established with long inlet nozzle)
600
4'
UR
2,0
500
400
1,5
4
3'
UN
300
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1800
272
73
—
A
2’
1740
333
67
53
A
3’
1725
355
67
65
A
4’
1770
307
70
49
A
1
1560
178
69
—
A
2
1515
220
63
53
A
3
1500
236
63
65
A
4
1530
208
65
49
A
5
1088
64
60
—
A
6
1065
79
56
53
A
7
1055
85
54
65
A
8
1070
75
56
49
A
9
470
9
44
—
A
10
450
10
42
53
A
11
450
11
40
65
A
12
455
10
40
49
1,0
3
n
[rpm]
2'
200
8
2
0,5
7
100
6
12
0
11
10
9
500
1000
254
1
5
1000
1'
1500
2000
2000
3000
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 355-AM08 -30
4.6
35560-2-4013
35561-2-4013
Inlet nozzle (long)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
255
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 355
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
3030
1410
168
3.50
66
-25 to +60
G)
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 355
M3G 084-FA
A
subject to alterations
2
[Pa]
4'
1,5
400
UR
300
1,0
3
UN
2'
8
2
0,5
7
100
6
12
11
10
500
1000
256
1
5
9
0
P1
[W]
LpA
[dB(A)]
tL
[%]
1’
1630
257
70
—
A
2’
1575
317
64
62
A
3’
1570
321
63
66
A
4’
1610
270
67
47
A
1
1410
168
66
—
A
2
1370
207
60
62
A
3
1365
212
59
66
A
4
1400
177
63
47
A
5
1065
75
58
—
A
6
1045
93
55
62
A
7
1040
96
55
66
A
8
1060
79
56
47
A
9
485
11
37
—
A
10
480
12
35
62
A
11
480
13
34
66
A
12
480
11
35
47
3'
4
200
n
[rpm]
A
A
2,0
500
[in H O]
Curves (established with long inlet nozzle)
1000
1500
2000
3000
1'
2000
[CFM]
4000
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 355-AN18 -30
4.8
35560-2-4013
35561-2-4013
Inlet nozzle (long)
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
257
Inlet nozzle
p. 550
Electr. connection
p. 600
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 400
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-FA
Power input
R3G 400
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
3000
1290
200
4.20
65
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
1,5
400
4
3'
UN
300
1,0
3
200
8
0,5
2'
7
2
100
12
6
11
10
0
1000
258
1
5
9
500
1000
1500
2000
3000
1'
2000
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1480
307
69
—
A
2’
1450
340
68
44
A
3’
1440
353
62
68
A
4’
1480
309
67
55
A
1
1290
200
65
—
A
2
1270
224
64
44
A
3
1260
234
59
68
A
4
1285
204
62
55
A
5
850
59
56
—
A
6
840
67
54
44
A
7
835
71
51
68
A
8
850
62
53
55
A
9
435
11
43
—
A
10
435
12
41
44
A
11
430
13
38
68
A
12
435
12
39
55
4'
UR
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 400-AD20 -30
5.0
54476-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
259
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 400
Sound pressure level
Perm. amb. temp.
Electr. connection
A
Current draw
M3G 084-FA
Power input
R3G 400
Speed/rpm
Motor
Air flow
Type
Voltage range
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VDC
VDC
m3/h
rpm
W
A
dB(A)
°C
p. 600
48
36-57
3300
1160
192
3.90
63
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
500
4'
1,5
400
UR
4
1,0
3
0,5
2
7
100
6
12
11
10
5
9
0
500
1000
260
1000
1
2000
1500
2000
3000
1'
[CFM]
[m3/h]
tL
[%]
1’
1325
287
69
—
2’
1300
340
66
43
A
3’
1300
335
64
62
A
4’
1345
268
68
53
A
1
1160
192
63
—
A
2
1140
227
62
43
A
3
1140
210
59
62
A
4
1170
177
63
53
A
5
795
62
57
—
A
6
784
74
56
43
A
7
780
69
56
62
A
8
795
59
56
53
A
9
500
15
49
—
A
10
500
19
48
43
A
11
500
21
48
62
A
12
505
18
49
53
200
2'
LpA
[dB(A)]
A
UN
8
P1
[W]
A
3'
300
n
[rpm]
General
information
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Over-temperature protected motor
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
• Tach output
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC
R3G 400-AC13 -30
kg
5.3
Inlet nozzle
(long)
EC centrifugal, backward for clean rooms
Centrifugal fan
54476-2-4013
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
12-14 mm
261
Inlet nozzle
p. 550
Guard grille
p. 553
Electr. connection
p. 600
Contacts
Technology
Accessories
Core-end sleeves
EC centrifugal fan
backward curved, Ø 133
Electr. connection
A
Perm. amb. temp.
M3G 055-BD
Max. current
draw(1)
R3G 133
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 601
50/60
4350
50
0.80
-25 to +60
H1)
1~ 115
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
4
8
1,0
300
3
12
200
0,5
6
2
15
10
14
13
0
50
100
262
100
9
150
200
5
200
300
400
1
250
[CFM]
[m3/h]
tL
[%]
4350
37
0.55
75
—
4310
41
0.60
74
39
A
3
4260
46
0.70
61
61
A
4
4340
41
0.60
60
45
A
5
4150
34
0.60
78
—
A
6
4090
36
0.60
69
31
A
7
4010
39
0.60
58
52
A
8
4080
34
0.60
58
47
A
9
3390
20
0.40
67
—
A
10
3350
22
0.40
58
30
A
11
3300
23
0.40
53
53
A
12
3350
22
0.40
53
46
A
13
2370
10
0.20
52
—
A
14
2360
11
0.20
49
30
A
15
2350
11
0.20
45
56
A
16
2370
11
0.20
44
46
7
16
LpA
[dB(A)]
2
11
100
I
[A]
1
1,5
400
P1
[W]
A
A
500
n
[rpm]
A
2
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 133-AE17 -02
1.0
09566-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
263
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 133
Electr. connection
A
Perm. amb. temp.
M3G 055-BD
Max. current
draw(1)
R3G 133
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 601
50/60
4480
52
0.40
-25 to +60
H1)
1~ 230
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
4
8
1,0
300
3
12
200
0,5
6
2
15
10
14
13
0
50
100
264
100
9
150
200
5
200
300
400
1
250
[CFM]
[m3/h]
tL
[%]
4480
43
0.30
75
—
4450
46
0.35
74
31
A
3
4390
49
0.40
61
51
A
4
4460
45
0.35
60
46
A
5
4150
34
0.30
78
—
A
6
4090
36
0.30
69
31
A
7
4010
39
0.30
58
52
A
8
4080
34
0.30
58
47
A
9
3390
20
0.20
67
—
A
10
3350
22
0.20
58
30
A
11
3300
23
0.20
53
53
A
12
3350
22
0.20
53
46
A
13
2370
10
0.10
52
—
A
14
2360
11
0.10
49
30
A
15
2350
11
0.10
45
56
A
16
2370
11
0.10
44
46
7
16
LpA
[dB(A)]
2
11
100
I
[A]
1
1,5
400
P1
[W]
A
A
500
n
[rpm]
A
2
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 133-AE07 -02
1.0
09566-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
265
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 175
Perm. amb. temp.
Electr. connection
M3G 055-CF
Max. current
draw(1)
R3G 175
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 601
50/60
3970
90
1.30
-25 to +60
H1)
1~ 115
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
500
A
2,0
600
[in H O]
Curves
1,5
400
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
3970
72
1.10
72
—
A
2
3870
81
1.20
67
45
A
3
3810
85
1.20
66
57
A
4
3790
88
1.30
65
52
A
5
3180
38
0.60
65
—
A
6
3110
45
0.70
61
39
A
7
3120
46
0.70
58
53
A
8
3110
47
0.70
56
51
A
9
2270
17
0.30
59
—
A
10
2240
20
0.35
54
38
A
11
2240
20
0.35
50
51
A
12
2240
21
0.35
50
50
A
13
1310
6
0.10
45
—
A
14
1295
7
0.10
40
40
A
15
1285
7
0.10
37
53
A
16
1290
7
0.10
35
54
4
300
1,0
3
8
200
0,5
7
2
12
6
100
11
16
10
15
14
13
0
9
100
100
266
n
[rpm]
200
200
300
1
5
300
400
500
400
600
700
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 175-AF25 -02
1.2
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
267
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 175
Frequency
Speed/rpm
Max. power
input(1)
Max. current
draw(1)
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
°C
p. 601
50/60
4460
120
1.00
-25 to +60
H1)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 175
M3G 055-CF
1~ 230
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
500
2,0
600
4
1,5
400
8
3
1,0
300
7
12
2
200
0,5
11
10
15
14
13
0
100
200
268
9
5
400
300
200
400
600
1
[CFM]
800
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
4460
100
0.75
76
—
A
2
4350
112
0.80
69
57
A
3
4300
115
0.85
66
68
A
4
4260
118
0.85
68
60
A
5
3800
65
0.50
71
—
A
6
3730
72
0.55
65
56
A
7
3710
76
0.55
74
66
A
8
3710
78
0.60
64
60
A
9
3110
37
0.30
66
—
A
10
3070
42
0.30
60
51
A
11
3060
44
0.35
58
61
A
12
3040
45
0.35
59
58
A
13
2170
17
0.15
59
—
A
14
2150
18
0.15
54
40
A
15
2150
18
0.15
50
51
A
16
2130
19
0.15
50
48
6
16
100
P1
[W]
A
A
700
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 175-AF19 -02
1.2
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
269
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 190
Perm. amb. temp.
Electr. connection
M3G 055-CF
Max. current
draw(1)
R3G 190
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 601
50/60
3370
87
1.40
-25 to +60
H1)
1~ 115
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
500
A
2,0
600
[in H O]
Curves
1,5
400
4
300
1,0
3
8
200
7
0,5
2
12
100
11
16
6
10
15
14
13
0
100
100
270
200
9
200
300
5
300
400
500
400
600
700
1
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
3370
76
1.10
70
—
A
2
3250
81
1.20
64
44
A
3
3220
84
1.20
63
55
A
4
3190
85
1.30
60
55
A
5
2715
42
0.70
64
—
A
6
2690
46
0.70
63
43
A
7
2670
48
0.80
58
54
A
8
2655
49
0.80
56
56
A
9
2310
27
0.40
61
—
A
10
2285
29
0.50
56
42
A
11
2265
31
0.50
55
52
A
12
2260
32
0.50
52
53
A
13
1780
15
0.20
58
—
A
14
1760
16
0.30
52
35
A
15
1750
17
0.30
48
43
A
16
1745
17
0.30
45
44
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 190-AB15 -02
1.3
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
271
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 190
Frequency
Speed/rpm
Max. power
input(1)
Max. current
draw(1)
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
°C
p. 601
50/60
3570
105
0.90
-25 to +60
H1)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 190
M3G 055-CF
1~ 230
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
1,5
400
4
1,0
300
200
12
7
0,5
2
11
16
6
10
15
14
13
0
100
100
272
300
9
5
300
200
200
I
[A]
LpA
[dB(A)]
tL
[%]
1
3570
90
0.65
72
—
A
2
3490
96
0.70
66
47
A
3
3440
101
0.75
64
57
A
4
3410
102
0.75
62
59
A
5
2950
51
0.40
65
—
A
6
2880
55
0.40
62
44
A
7
2860
58
0.45
60
55
A
8
2840
60
0.45
57
58
A
9
2510
33
0.25
62
—
A
10
2480
36
0.30
58
43
A
11
2470
39
0.30
57
53
A
12
2450
40
0.30
54
56
A
13
1940
18
0.15
57
—
A
14
1920
19
0.15
54
37
A
15
1900
20
0.15
51
46
A
16
1890
22
0.15
47
48
3
8
100
P1
[W]
A
A
600
n
[rpm]
400
500
1
400
600
700
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 190-AB23 -02
1.3
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
273
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 190
Perm. amb. temp.
Electr. connection
M3G 074-BF
Max. current
draw(1)
R3G 190
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
3960
170
2.50
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
700
4
500
2,0
600
8
3
1,5
400
12
7
1,0
300
200
11
2
0,5
16
100
6
15
10
14
13
0
100
200
274
9
5
300
200
400
1
400
600
[CFM]
800
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
3960
146
1.80
73
—
A
2
3940
149
1.90
71
32
A
3
3900
156
2.00
68
48
A
4
4000
147
1.90
69
43
A
5
3430
94
1.20
70
—
A
6
3370
95
1.30
66
31
A
7
3310
99
1.30
64
47
A
8
3420
95
1.30
64
41
A
9
2830
58
0.80
64
—
A
10
2790
59
0.80
62
28
A
11
2720
58
0.80
58
45
A
12
2830
57
0.80
60
39
A
13
1960
24
0.40
58
—
A
14
1950
25
0.40
56
23
A
15
1910
25
0.40
50
37
A
16
1940
24
0.40
50
31
A
800
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 190-AF60 -01
1.8
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
275
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 190
Perm. amb. temp.
Electr. connection
M3G 074-BF
Max. current
draw(1)
R3G 190
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
4050
156
1.15
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
3,0
700
4
500
2,0
600
8
3
400
12
1,0
11
200
2
16
6
15
10
14
13
0
100
200
276
I
[A]
LpA
[dB(A)]
tL
[%]
1
4050
149
1.10
74
—
A
2
4040
156
1.10
72
35
A
3
4010
155
1.10
69
52
A
4
4090
142
1.00
69
43
A
5
3490
101
0.70
70
—
A
6
3460
104
0.70
68
33
A
7
3250
103
0.70
65
51
A
8
3535
96
0.70
65
41
A
9
2925
62
0.50
66
—
A
10
2915
63
0.50
64
33
A
11
2900
63
0.50
60
52
A
12
2930
60
0.50
61
42
A
13
2040
27
0.20
59
—
A
14
2050
27
0.20
56
33
A
15
2040
27
0.20
51
51
A
16
2060
26
0.20
51
39
7
300
100
P1
[W]
A
A
800
n
[rpm]
200
9
300
400
600
5
400
1
[CFM]
800
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 190-AF50 -01
1.8
09576-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
277
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 220
Frequency
Speed/rpm
Max. power
input(1)
Max. current
draw(1)
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
°C
p. 601
50/60
2620
75
1.10
-25 to +60
H1)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 220
M3G 055-CF
1~ 115
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
1,0
4
200
8
0,5
2
11
16
6
10
15
14
13
0
200
278
9
200
5
400
400
600
800
1
600
[CFM]
1000
[m3/h]
LpA
[dB(A)]
tL
[%]
1
2620
55
0.80
69
—
2
2480
64
1.00
67
55
A
3
2370
71
1.00
59
63
A
4
2450
66
1.00
63
47
A
5
2340
40
0.60
67
—
A
6
2260
48
0.70
64
53
A
7
2200
53
0.80
57
62
A
8
2250
51
0.80
59
47
A
9
1890
22
0.40
64
—
A
10
1820
27
0.40
60
48
A
11
1790
30
0.50
52
60
A
12
1820
28
0.40
55
45
A
13
1180
8
0.20
56
—
A
14
1150
9
0.20
52
34
A
15
1130
10
0.20
42
44
A
16
1150
10
0.20
43
33
7
100
I
[A]
A
3
12
P1
[W]
A
400
300
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 220-AD21 -02
1.4
09609-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
279
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 220
Frequency
Speed/rpm
Max. power
input(1)
Max. current
draw(1)
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
°C
p. 601
50/60
3030
105
0.80
-25 to +60
H1)
Curve
Nominal voltage
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R3G 220
M3G 055-CF
1~ 230
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
400
1,5
4
8
300
0,5
6
16
10
15
14
13
0
200
280
9
200
5
400
400
600
800
1
600
[CFM]
1000
[m3/h]
tL
[%]
3030
80
0.60
71
—
2880
93
0.70
68
57
A
3
2750
102
0.75
62
64
A
4
2800
99
0.75
66
48
A
5
2660
54
0.40
69
—
A
6
2540
64
0.50
66
56
A
7
2450
73
0.55
59
64
A
8
2500
70
0.55
63
48
A
9
2150
30
0.25
65
—
A
10
2070
36
0.30
62
54
A
11
2010
41
0.30
55
62
A
12
2060
39
0.30
57
48
A
13
1340
10
0.10
58
—
A
14
1310
12
0.10
55
38
A
15
1280
13
0.10
48
48
A
16
1300
13
0.10
45
36
2
100
LpA
[dB(A)]
2
7
11
I
[A]
1
1,0
200
P1
[W]
A
3
12
n
[rpm]
A
A
2,0
500
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 220-AD17 -02
1.4
09609-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
281
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 220
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 220
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
3590
160
2.50
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
3,0
2,5
700
600
500
2,0
4
8
3
300
7
1,0
200
0,5
11
10
100
15
14
13
200
282
9
200
0
400
400
600
800
5
1
600
[CFM]
1000
[m3/h]
tL
[%]
3590
158
2.00
74
—
2
3360
164
2.10
70
47
A
3
3260
160
2.00
66
58
A
4
3330
164
2.10
71
47
A
5
3110
106
1.40
72
—
A
6
2890
110
1.40
66
45
A
7
2810
108
1.40
62
54
A
8
2870
114
1.50
66
44
A
9
2510
62
0.90
68
—
A
10
2350
60
0.80
62
43
A
11
2280
60
0.80
56
52
A
12
2330
61
0.90
60
44
A
13
1590
21
0.30
60
—
A
14
1520
23
0.30
52
31
A
15
1470
21
0.30
46
42
A
16
1500
21
0.30
50
34
6
16
LpA
[dB(A)]
1
12
2
I
[A]
A
1,5
400
P1
[W]
A
A
800
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 220-AE70 -01
2.2
09609-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
283
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 220
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 220
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
3560
170
1.20
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
3,0
800
700
600
2,0
500
4
8
3
400
7
300
12
1,0
10
16
100
15
14
13
200
284
9
200
0
400
400
600
800
1
5
600
[CFM]
1000
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
3560
151
1.10
76
—
2
3400
172
1.20
70
51
A
3
3320
166
1.20
67
53
A
4
3440
173
1.20
71
44
A
5
3080
103
0.80
71
—
A
6
3010
120
0.90
67
49
A
7
3000
123
0.90
63
53
A
8
3035
117
0.90
67
43
A
9
2500
62
0.50
67
—
A
10
2435
66
0.50
63
46
A
11
2430
69
0.50
58
52
A
12
2455
71
0.50
61
41
A
13
1625
23
0.20
60
—
A
14
1595
24
0.20
54
49
A
15
1595
26
0.20
48
52
A
16
1605
24
0.20
51
45
11
6
P1
[W]
A
2
200
n
[rpm]
A
A
2
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 220-AE50 -01
2.2
09609-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
285
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 225
Electr. connection
A
Perm. amb. temp.
M3G 055-CF
Max. current
draw(1)
R3G 225
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 601
50/60
2500
95
0.75
-25 to +60
H1)
1~ 230
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
1,5
400
8
1,0
3
200
7
12
0,5
6
16
100
15
10
14
13
200
0
200
286
9
400
400
600
800
5
600
1000
1
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2500
80
0.60
69
—
2
2380
88
0.65
62
60
A
3
2290
94
0.70
57
61
A
4
2410
84
0.65
62
45
A
5
2190
56
0.45
66
—
A
6
2110
61
0.45
60
61
A
7
2050
66
0.50
54
61
A
8
2140
60
0.45
60
45
A
9
1830
34
0.25
62
—
A
10
1790
38
0.30
57
60
A
11
1750
41
0.30
51
61
A
12
1810
36
0.30
54
44
A
13
1350
16
0.15
56
—
A
14
1320
17
0.15
50
50
A
15
1290
19
0.15
45
53
A
16
1330
16
0.15
45
39
11
2
P1
[W]
A
4
300
n
[rpm]
A
A
2,0
500
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 225-AE11 -02
1.5
96358-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw
max. 6 mm
287
Inlet nozzle
p. 550
Electr. connection
p. 601
Contacts
Technology
Brass lead tips
EC centrifugal fan
backward curved, Ø 225
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 225
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2850
160
2.20
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
4
1,5
400
3
8
300
1,0
7
12
200
11
0,5
2
6
16
100
10
15
14
13
200
0
200
288
9
400
400
600
800
5
600
1
[CFM]
1000
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2850
131
1.70
70
—
A
2
2800
149
1.90
67
50
A
3
2760
155
2.00
62
59
A
4
2845
136
1.70
66
45
A
5
2460
84
1.10
67
—
A
6
2420
95
1.30
63
50
A
7
2410
102
1.30
59
58
A
8
2460
91
1.20
63
44
A
9
2020
51
0.70
63
—
A
10
1990
58
0.80
61
46
A
11
1980
60
0.80
54
56
A
12
2010
52
0.70
57
42
A
13
1350
20
0.30
56
—
A
14
1340
21
0.30
52
37
A
15
1340
23
0.40
44
45
A
16
1350
21
0.30
35
32
A
600
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 225-AH71 -01
2.3
96358-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
289
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 225
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 225
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
3010
165
1.20
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
3,0
800
700
600
2,0
8
400
3
300
7
1,0
12
11
200
2
16
6
15
100
10
14
200
290
13
400
200
0
400
600
9
800
5
600
1
[CFM]
1000
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
1
3010
139
1.00
71
—
A
2
2930
153
1.10
67
43
A
3
2900
162
1.20
63
52
A
4
2970
148
1.10
68
39
A
5
2640
97
0.70
68
—
A
6
2600
105
0.80
64
44
A
7
2570
116
0.90
60
57
A
8
2605
100
0.80
65
43
A
9
2190
59
0.50
65
—
A
10
2150
67
0.50
61
46
A
11
2135
71
0.60
55
56
A
12
2160
62
0.50
59
44
A
13
1540
27
0.20
61
—
A
14
1530
29
0.20
53
43
A
15
1520
31
0.30
47
55
A
16
1530
28
0.20
50
42
4
500
n
[rpm]
A
A
2
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 225-AH54 -01
2.3
96358-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
291
Inlet nozzle
p. 550
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 250
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 250
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2630
145
1.90
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
2,5 [in H O]
Curves
2,0
500
4
1,5
400
8
3
300
1,0
7
12
200
11
0,5
100
6
15
10
14
13
0
200
200
292
9
400
400
600
5
1
600
800
1000
[CFM]
1200
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2630
106
1.40
70
—
A
2
2540
127
1.60
66
57
A
3
2480
140
1.80
61
60
A
4
2560
125
1.60
67
47
A
5
2315
72
1.00
68
—
A
6
2240
90
1.20
63
54
A
7
2200
99
1.40
59
60
A
8
2260
87
1.20
63
46
A
9
1900
43
0.70
66
—
A
10
1870
55
0.80
60
51
A
11
1835
60
0.90
53
58
A
12
1860
53
0.80
58
43
A
13
1290
18
0.30
58
—
A
14
1275
21
0.40
52
40
A
15
1250
22
0.40
44
49
A
16
1270
19
0.30
48
37
2
16
P1
[W]
A
A
600
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AH74 -01
2.5
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
293
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 250
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 250
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: PA plastic 6.6, fibreglass-reinforced
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2760
160
1.20
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
700
500
2,0
600
4
400
8
3
300
7
1,0
12
11
200
2
6
16
100
15
10
14
13
0
200
200
294
9
400
400
600
5
600
800
1000
1
[CFM]
1200
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2760
123
0.90
71
—
A
2
2660
148
1.10
66
54
A
3
2600
162
1.20
62
57
A
4
2680
147
1.10
68
42
A
5
2460
88
0.70
68
—
A
6
2380
106
0.80
63
53
A
7
2340
116
0.90
59
57
A
8
2400
105
0.80
65
42
A
9
2000
53
0.40
65
—
A
10
1960
62
0.50
60
54
A
11
1940
69
0.50
55
58
A
12
1965
61
0.50
59
42
A
13
1380
22
0.20
58
—
A
14
1360
25
0.20
52
50
A
15
1350
28
0.25
47
57
A
16
1360
25
0.20
50
43
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AH52 -01
2.5
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Core-end sleeves
295
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
EC centrifugal fan
backward curved, Ø 250
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw(1)
R3G 250
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2490
125
1.80
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
n
[rpm]
2
[Pa]
4
1,5
400
3
8
1,0
300
7
12
200
11
0,5
2
6
100
16
10
15
14
13
0
200
296
9
200
400
400
600
1
5
600
800
1000
[CFM]
1200
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2490
97
1.30
72
—
A
2
2380
119
1.60
66
62
A
3
2330
123
1.60
60
64
A
4
2410
110
1.40
67
47
A
5
2110
60
0.80
71
—
A
6
2040
78
1.00
63
58
A
7
2010
79
1.10
58
64
A
8
2070
71
1.00
64
45
A
9
1700
35
0.50
66
—
A
10
1660
44
0.60
58
56
A
11
1650
47
0.70
52
59
A
12
1670
39
0.60
58
43
A
13
1040
11
0.20
57
—
A
14
1030
14
0.20
50
40
A
15
1030
15
0.20
41
46
A
16
1040
13
0.20
44
31
A
2,0
500
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AL75 -01
2.9
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
297
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 250
Electr. connection
A
Perm. amb. temp.
M3G 074-CF
Max. current
draw(1)
R3G 250
Max. power
input(1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2800
175
1.30
-25 to +60
J1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
700
600
500
2,0
4
8
400
3
1,0
12
11
200
2
6
16
100
10
15
14
0
200
298
13
400
200
400
600
800
9
600
5
1000
1200
1
800
1400
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2800
142
1.10
74
—
A
2
2650
164
1.25
69
53
A
3
2570
164
1.25
63
59
A
4
2720
154
1.20
72
44
A
5
2550
104
0.80
71
—
A
6
2470
124
1.00
66
53
A
7
2440
134
1.00
61
58
A
8
2510
123
0.90
69
44
A
9
2080
62
0.50
67
—
A
10
2025
74
0.60
62
54
A
11
2020
78
0.60
56
60
A
12
2050
70
0.60
62
43
A
13
1370
24
0.20
59
—
A
14
1340
27
0.20
53
51
A
15
1330
28
0.20
46
57
A
16
1340
25
0.20
51
44
7
300
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AL54 -01
2.9
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
299
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 250
Electr. connection
A
Perm. amb. temp.
M3G 074-CF
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2570
170
2.20
-25 to +60
J1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
[Pa]
2
4
400
1,5
300
1,0
2
200
11
0,5
16
10
15
14
0
200
300
13
400
200
400
600
9
5
600
800
1000
800
1200
1400
1
[CFM]
[m3/h]
LpA
[dB(A)]
tL
[%]
2570
147
1.90
73
—
2
2440
167
2.10
66
62
A
3
2420
166
2.10
62
63
A
4
2580
147
1.90
69
44
A
5
2220
106
1.30
71
—
A
6
2100
108
1.40
64
60
A
7
2090
110
1.50
60
58
A
8
2220
93
1.20
65
45
A
9
1820
59
0.80
69
—
A
10
1730
67
0.90
60
54
A
11
1720
66
0.90
54
55
A
12
1810
59
0.80
60
39
A
13
1220
23
0.30
62
—
A
14
1180
27
0.40
52
43
A
15
1180
25
0.40
44
46
A
16
1210
23
0.30
48
30
6
100
I
[A]
1
7
12
P1
[W]
A
3
8
n
[rpm]
A
A
2,0
500
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AM70 -01
3.0
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
301
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 250
Electr. connection
A
Perm. amb. temp.
M3G 074-CF
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2510
178
1.40
-25 to +60
J1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
4
400
3
8
300
1,0
2
200
11
6
16
100
10
15
14
0
200
302
13
400
200
400
600
800
9
600
5
1000
1200
1
[CFM]
1400
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2510
140
1.00
73
—
A
2
2450
166
1.20
66
53
A
3
2440
172
1.20
62
56
A
4
2520
143
1.00
68
41
A
5
2170
99
0.75
69
—
A
6
2140
112
0.90
64
52
A
7
2130
115
0.90
59
54
A
8
2170
95
0.80
63
40
A
9
1770
55
0.40
66
—
A
10
1750
67
0.50
58
52
A
11
1750
67
0.50
54
53
A
12
1765
59
0.50
59
39
A
13
1230
26
0.20
59
—
A
14
1240
27
0.30
51
50
A
15
1220
29
0.30
45
56
A
16
1240
27
0.30
48
43
7
12
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AM50 -01
3.0
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
303
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 250
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
3240
350
4.20
-25 to +60
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
3,0
800
4
2,0
600
3
400
1,0
2
200
1
0
250
400
304
500
800
750
1200
1000
1600
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
3240
267
3.30
77
—
A
2
3160
339
4.10
73
54
A
3
3165
350
4.20
71
58
A
4
3210
314
3.80
73
52
A
4,0
1000
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AK29 -81
4.5
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
305
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 250
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
3580
485
3.00
-25 to +60
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
A
4,0
1000
[in H O]
Curves
4
3,0
800
3
600
2,0
8
7
400
2
1,0
12
6
11
200
10
5
9
0
250
400
306
500
800
750
1200
1000
1600
1
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
3580
380
2.30
80
—
A
2
3460
465
3.00
77
53
A
3
3460
485
3.00
74
58
A
4
3520
440
2.40
76
50
A
5
2830
193
1.20
75
—
A
6
2830
245
1.50
70
53
A
7
2830
260
1.60
69
58
A
8
2830
225
1.40
69
50
A
9
2000
80
0.50
68
—
A
10
2000
100
0.60
62
53
A
11
2000
106
0.70
59
58
A
12
2000
94
0.60
60
50
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 250-AK41 -71
4.5
96359-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
307
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 280
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
1750
145
1.90
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
1,25
300
250
1,00
4
8
3
0,75
200
7
150
0,50
100
0,25
6
50
15
10
14
13
0
200
400
308
400
9
600
800
5
800
1200
1
1000
1600
[CFM]
[m3/h]
LpA
[dB(A)]
tL
[%]
1
1750
107
1.40
70
—
2
1710
123
1.60
63
51
A
3
1675
138
1.80
59
67
A
4
1720
119
1.50
60
53
A
5
1550
73
1.00
66
—
A
6
1530
89
1.20
61
49
A
7
1500
99
1.30
56
66
A
8
1540
86
1.10
57
52
A
9
1280
45
0.60
62
—
A
10
1250
51
0.70
55
45
A
11
1230
58
0.80
51
62
A
12
1260
50
0.70
52
49
A
13
880
18
0.30
57
—
A
14
870
21
0.30
51
36
A
15
870
23
0.40
46
51
A
16
880
20
0.30
40
39
2
16
I
[A]
A
12
11
P1
[W]
A
A
350
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 280-AA75 -01
3.2
96360-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
309
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 280
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
2000
170
1.30
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
300
1,0
8
3
200
7
0,5
12
2
16
6
15
10
14
13
0
250
400
310
9
500
800
5
1000
750
1200
1600
1
[CFM]
2000 [m /h]
3
I
[A]
LpA
[dB(A)]
tL
[%]
1
2000
145
1.10
72
—
A
2
1920
168
1.20
67
48
A
3
1790
170
1.20
61
60
A
4
1930
161
1.10
62
50
A
5
1680
89
0.70
69
—
A
6
1660
113
0.90
64
46
A
7
1625
123
1.00
57
61
A
8
1660
104
0.80
58
50
A
9
1380
55
0.50
65
—
A
10
1350
61
0.50
60
49
A
11
1340
72
0.60
53
60
A
12
1360
61
0.50
53
50
A
13
980
24
0.20
58
—
A
14
970
28
0.30
54
47
A
15
960
32
0.30
48
60
A
16
970
27
0.30
44
51
11
100
P1
[W]
A
400
4
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 280-AA52 -01
3.2
96360-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
311
Inlet nozzle
p. 550 f.
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 280
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2420
350
4.20
-25 to +60
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
2,5
3,0
800
2,0
600
1,5
3
1,0
400
4
200
0,5
2
1
0
250
400
312
500
800
750
1200
1000
1600
1250
2000
1500
2400
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2420
270
3.30
77
—
A
2
2360
324
3.90
73
50
A
3
2320
350
4.20
69
60
A
4
2395
298
3.70
71
48
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 280-AF23 -81
5.0
96360-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
313
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, Ø 280
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet steel, galvanised
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 11
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2600
455
2.80
-25 to +40
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
3,0
800
2,5
4
2,0
600
8
7
1,0
400
1,5
3
2
200
12
6
0,5
11
10
9
0
250
400
314
500
800
750
1200
1000
1600
5
1250
2000
1500
2400
1
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2760
355
2.20
80
—
A
2
2670
400
2.50
77
48
A
3
2660
425
2.60
73
60
A
4
2740
386
2.30
75
45
A
5
2050
150
1.00
74
—
A
6
2050
206
1.10
71
48
A
7
2050
232
1.40
67
60
A
8
2050
196
1.20
67
45
A
9
1460
65
0.40
67
—
A
10
1460
80
0.50
64
48
A
11
1460
88
0.60
58
60
A
12
1460
70
0.50
57
45
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 280-AF35 -71
5.0
96360-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA; CCC, GOST are applied for
Accessories
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
315
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
R3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
1700
160
2.10
-25 to +60
J1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
1,5
1,0
8
3
200
7
12
0,5
11
100
16
2
6
15
10
14
13
0
250
400
316
9
500
800
5
750
1200
1000
1600
1
[CFM]
2000 [m /h]
3
I
[A]
LpA
[dB(A)]
tL
[%]
1
1700
111
1.50
65
—
A
2
1640
133
1.70
62
64
A
3
1600
152
1.90
58
75
A
4
1630
140
1.80
60
55
A
5
1530
80
1.10
62
—
A
6
1480
98
1.30
60
63
A
7
1450
110
1.50
55
75
A
8
1470
103
1.40
58
58
A
9
1270
50
0.70
58
—
A
10
1240
61
0.80
55
57
A
11
1220
68
0.90
52
73
A
12
1230
64
0.90
53
54
A
13
920
22
0.40
49
—
A
14
900
26
0.40
46
49
A
15
890
30
0.50
43
64
A
16
900
28
0.40
45
48
400
300
P1
[W]
A
A
4
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 310-AO75 -01
3.1
31050-2-4013
31051-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
Inlet nozzle (long)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
317
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
R3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
1925
173
1.30
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves (established with long inlet nozzle)
400
1,5
4
8
300
1,0
3
7
12
200
0,5
11
16
6
15
10
14
13
0
250
400
318
500
750
800
1000
1200
9
1250
1600
5
1500
2000
1
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1925
150
1.10
67
—
A
2
1840
174
1.20
65
61
A
3
1700
172
1.20
59
71
A
4
1790
174
1.20
62
55
A
5
1670
100
0.80
64
—
A
6
1615
128
1.00
61
60
A
7
1590
139
1.00
55
71
A
8
1610
134
1.00
60
53
A
9
1400
60
0.50
59
—
A
10
1360
76
0.60
57
60
A
11
1340
85
0.70
54
73
A
12
1355
81
0.70
56
54
A
13
1030
28
0.30
51
—
A
14
1010
35
0.30
49
59
A
15
990
40
0.30
45
72
A
16
1000
38
0.30
47
53
2
100
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 310-AO52 -01
3.1
31050-2-4013
31051-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
Inlet nozzle (long)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
319
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fan
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
R3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, laser-welded
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 603
50/60
1770
175
1.30
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves (established with long inlet nozzle)
1,5
400
1,0
8
0,5
7
2
12
100
11
6
10
9
0
250
500
600
320
750
1200
1
1500
5
1000
1800
1250
2400
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1770
170
1.25
65
—
A
2
1570
170
1.30
60
59
A
3
1510
167
1.30
58
65
A
4
1630
169
1.20
62
49
A
5
1300
73
0.60
56
—
A
6
1270
88
0.70
54
59
A
7
1250
100
0.80
54
65
A
8
1280
84
0.70
56
48
A
9
930
29
0.30
48
—
A
10
910
37
0.30
45
56
A
11
900
40
0.35
45
67
A
12
910
34
0.30
46
47
3
200
P1
[W]
A
4
300
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
R3G 310-AP52 -01
3.2
31050-2-4013
31051-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
Depth of screw max. 8 mm
(core removing hole prepared for self-tapping screw)
Inlet nozzle (long)
EC centrifugal,
forward
Depth of screw max. 6 mm
(core removing hole prepared for self-tapping screw)
Accessories
EC-SYSTEMS
Depth of screw 8-10 mm
321
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 603
Contacts
Technology
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2300
350
4.20
-25 to +60
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
A
3,5
1000
4
2,0
600
2,5
3,0
800
1,5
400
3
1,0
2
0,5
200
1
0
500
500
322
1000
1000
1500
1500
2000
2500
[CFM]
3000
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2300
262
3.30
75
—
A
2
2190
338
4.10
69
64
A
3
2180
350
4.20
71
67
A
4
2260
307
3.70
70
52
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 310-AJ23 -81
4.4
31050-2-4013
31051-2-4013
K3G 310-AJ23 -82
7.3
K3G 310-AJ23 -81
7.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
192,4±3
143,9
2,5
440±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
350±1
5
tes!
minu
6,4±0,2
8
85
1000±50
420±0,5
323
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2590
505
3.10
-25 to +60
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
800
3,0
4
2,5
3
2
11
1,0
6
200
10
0,5
16
15
14
9
13
0
500
500
324
LpA
[dB(A)]
tL
[%]
1
2590
380
2.30
78
—
2
2500
470
2.80
74
63
A
3
2470
505
3.00
73
67
A
4
2530
460
2.70
74
52
A
5
2320
274
1.60
75
—
A
6
2320
370
2.20
71
63
A
7
2320
410
2.40
71
67
A
8
2320
362
2.10
71
52
A
9
1810
137
0.90
69
—
A
10
1810
175
1.10
65
63
A
11
1810
198
1.20
64
67
A
12
1810
180
1.10
64
52
A
13
1110
42
0.30
55
—
A
14
1110
54
0.40
52
63
A
15
1110
57
0.40
52
67
A
16
1110
54
0.40
52
52
12
1,5
400
7
I
[A]
A
8
2,0
600
P1
[W]
A
3,5
1000
n
[rpm]
1000
1000
1500
5
1
1500
2000
2500
[CFM]
3000
[m3/h]
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 310-AJ40 -71
4.4
31050-2-4013
31051-2-4013
K3G 310-AJ40 -72
7.3
K3G 310-AJ40 -71
7.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
192,4±3
143,9
2,5
440±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
350±1
5
tes!
minu
6,4±0,2
8
85
1000±50
420±0,5
325
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2080
350
4.20
-25 to +60
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2,5
700
600
2,0
4
500
1,5
400
3
1,0
300
2
0,5
200
100
1
0
500
500
326
1000
1500
1000
1500
2000
2500
[CFM]
3000
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2080
274
3.40
71
—
A
2
1980
338
4.10
68
63
A
3
1950
350
4.20
66
67
A
4
2035
301
3.70
69
52
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 310-AI01 -81
4.5
31050-2-4013
31051-2-4013
K3G 310-AI01 -82
7.6
K3G 310-AI01 -81
7.1
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
223,5±3
175
2,5
440±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
350±1
5
tes!
minu
6,4±0,2
8
85
1000±50
420±0,5
327
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 310
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
2300
480
3.10
-25 to +60
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
500
400
2,8
2,4
4
2,0
600
3
8
1,6
700
300
1,2
7
12
2
0,8
11
200
6
16
15
0,4
100
10
14
0
500
328
1000
1500
1
[CFM]
5
9
13
1000
500
1500
2000
2500
3000
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2300
370
2.35
75
—
A
2
2215
445
2.85
71
62
A
3
2170
480
3.10
68
67
A
4
2220
448
2.85
70
56
A
5
1900
210
1.30
69
—
A
6
1900
284
1.70
66
62
A
7
1900
312
1.80
63
67
A
8
1900
278
1.70
66
56
A
9
1560
124
0.80
63
—
A
10
1560
158
1.00
61
62
A
11
1560
175
1.10
57
67
A
12
1560
158
1.00
61
56
A
13
1200
57
0.40
56
—
A
14
1200
73
0.50
54
62
A
15
1200
80
0.50
53
67
A
16
1200
70
0.50
53
56
A
800
n
[rpm]
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 310-AI39 -71
4.5
31050-2-4013
31051-2-4013
K3G 310-AI39 -72
7.6
K3G 310-AI39 -71
7.1
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
223,5±3
175
2,5
440±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
350±1
5
tes!
minu
6,4±0,2
8
85
1000±50
420±0,5
329
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1730
355
4.10
-25 to +60
K1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
2,5
700
500
2,0
600
4
1,5
400
3
1,0
300
200
0,5
2
100
1
0
500
500
330
1000
1000
1500
1500
2000
2500
2000
3000
3500
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1730
278
3.20
74
—
A
2
1675
338
3.90
69
58
A
3
1650
355
4.20
66
70
A
4
1700
310
3.60
68
60
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AM36 -81
5.7
35560-2-4013
35561-2-4013
K3G 355-AM36 -82
9.2
K3G 355-AM36 -81
8.8
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
2,5
496±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
5
tes!
minu
6,4±0,2
8
85
1000±50
476±0,5
331
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
233,5±3
185
380±1
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1970
500
3.15
-25 to +60
K1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
400
300
2,4
2,0
500
4
8
7
12
0,8
2
200
0,4
100
16
10
15
14
0
500
500
332
1000
9
13
1000
1500
5
1500
2000
2500
2000
3000
3500
1
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1970
390
2.50
77
—
A
2
1920
469
2.95
73
56
A
3
1880
500
3.15
69
70
A
4
1925
476
3.00
71
62
A
5
1580
200
1.20
71
—
A
6
1580
260
1.50
67
56
A
7
1580
290
1.70
64
70
A
8
1580
265
1.60
64
62
A
9
1280
110
0.70
65
—
A
10
1280
144
0.90
61
56
A
11
1280
157
1.00
58
70
A
12
1280
132
0.80
59
62
A
13
910
44
0.30
55
—
A
14
910
57
0.40
52
56
A
15
910
62
0.40
49
70
A
16
910
48
0.40
50
62
11
6
P1
[W]
A
3
1,6
600
1,2
700
2,8
800
n
[rpm]
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AM29 -71
5.7
35560-2-4013
35561-2-4013
K3G 355-AM29 -72
9.2
K3G 355-AM29 -71
8.8
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
2,5
496±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
5
tes!
minu
6,4±0,2
8
85
1000±50
476±0,5
333
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
233,5±3
185
380±1
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1630
350
4.20
-25 to +60
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
2,5
700
500
2,0
600
4
1,5
400
300
1,0
3
200
0,5
2
100
1
0
500
500
334
1000
1000
1500
1500
2000
2500
2000
3000
3500
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1630
283
3.50
72
—
A
2
1580
344
4.00
68
58
A
3
1570
350
4.20
64
68
A
4
1605
319
3.90
67
57
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AN37 -81
5.8
35560-2-4013
35561-2-4013
K3G 355-AN37 -82
10.0
K3G 355-AN37 -81
9.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
2,5
496±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
5
tes!
minu
6,4±0,2
8
85
1000±50
476±0,5
335
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
257,5±3
209
380±1
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1770
450
2.90
-25 to +60
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2,5
600
2,0
500
4
8
400
1,5
3
7
12
300
1,0
11
16
200
2
15
6
0,5
10
14
100
0
500
500
336
1000
13
1500
1000
1500
2000
2500
9
5
2000
3000
3500
1
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1770
362
2.30
73
—
A
2
1720
434
2.75
68
58
A
3
1710
450
2.90
64
68
A
4
1745
412
2.60
67
57
A
5
1620
270
1.60
73
—
A
6
1620
360
2.10
67
58
A
7
1620
375
2.20
63
68
A
8
1620
335
2.00
65
57
A
9
1400
182
1.10
67
—
A
10
1400
235
1.40
64
58
A
11
1400
247
1.50
59
68
A
12
1400
218
1.30
62
57
A
13
1200
120
0.80
62
—
A
14
1200
152
1.00
59
58
A
15
1200
160
1.00
56
68
A
16
1200
140
0.90
57
57
A
700
n
[rpm]
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
General
information
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AN04 -71
5.8
35560-2-4013
35561-2-4013
K3G 355-AN04 -72
10.0
K3G 355-AN04 -71
9.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
2,5
496±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
5
tes!
minu
6,4±0,2
8
85
1000±50
476±0,5
337
Inlet nozzle
p. 550 f.
Electr. connection
p. 605
Contacts
257,5±3
209
380±1
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
2035
0.74
3.34
-25 to +60
L1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2,5
700
4
500
2,0
600
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
tL
[%]
A
1
2035
0.57
2.60
84
—
A
2
2035
0.69
3.10
81
52
A
3
2035
0.74
3.30
78
64
A
4
2035
0.70
3.10
82
61
A
5
1585
0.28
1.30
76
—
A
6
1580
0.32
1.50
73
52
A
7
1580
0.34
1.60
71
71
A
8
1580
0.33
1.50
73
68
A
9
1150
0.12
0.60
67
—
A
10
1145
0.14
0.70
64
54
A
11
1140
0.15
0.70
63
74
A
12
1145
0.14
0.60
64
72
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
3
400
1,5
8
300
7
1,0
2
12
200
6
0,5
11
100
10
0
500
1000
338
9
1500
1000
2000
5
2000
3000
1
2500
4000
[CFM]
[m3/h]
General
information
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AI52 -11
7.3
35560-2-4013
35561-2-4013
K3G 355-AI52 -12
15.8
K3G 355-AI52 -11
18.6
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Technology
Accessories
Depth of screw 12-16 mm
339
Inlet nozzle
p. 550 f.
Electr. connection
p. 607
Contacts
Cable gland
EC-SYSTEMS
EC centrifugal,
forward
Inlet nozzle (long)
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
2215
0.94
3.00
-25 to +60
L2)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
3,0
600
3
2,0
8
400
7
2
1,0
12
200
6
11
10
9
0
500
1000
340
1000
1500
2000
5
2000
3000
2500
4000
1
[CFM]
[m3/h]
P1
[kW]
I
[A]
LwA
[dB(A)]
tL
[%]
1
2205
0.70
2.50
87
—
A
2
2215
0.88
2.80
83
48
A
3
2215
0.94
3.00
80
59
A
4
2215
0.85
2.70
85
53
A
5
1825
0.38
1.50
82
—
A
6
1805
0.47
1.70
77
52
A
7
1790
0.49
1.80
73
65
A
8
1800
0.46
1.90
77
58
A
9
1335
0.17
0.70
72
—
A
10
1315
0.20
0.80
68
57
A
11
1315
0.21
0.90
65
69
A
12
1310
0.19
0.80
67
60
800
4
n
[rpm]
A
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AI62 -06
7.3
35560-2-4013
35561-2-4013
K3G 355-AI62 -07
15.8
K3G 355-AI62 -06
18.6
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Technology
Accessories
Depth of screw 12-16 mm
341
Inlet nozzle
p. 550 f.
Electr. connection
p. 607
Contacts
Cable gland
EC-SYSTEMS
EC centrifugal,
forward
Inlet nozzle (long)
EC centrifugal fans and modules
backward curved, 3-D, Ø 355
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
2215
0.94
1.50
-25 to +60
L2)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
3,0
600
3
2,0
8
400
7
2
1,0
12
200
6
11
10
9
0
500
1000
342
1000
1500
2000
5
2000
3000
2500
4000
1
[CFM]
[m3/h]
P1
[kW]
I
[A]
LwA
[dB(A)]
tL
[%]
1
2205
0.70
1.30
87
—
A
2
2215
0.88
1.40
83
48
A
3
2215
0.94
1.50
80
59
A
4
2215
0.85
1.40
85
53
A
5
1825
0.38
0.70
82
—
A
6
1805
0.47
0.90
77
52
A
7
1790
0.49
0.90
73
65
A
8
1800
0.46
0.90
77
58
A
9
1335
0.17
0.40
72
—
A
10
1315
0.20
0.40
68
57
A
11
1315
0.21
0.40
65
69
A
12
1310
0.19
0.40
67
60
800
4
n
[rpm]
A
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 355-AI56 -01
7.3
35560-2-4013
35561-2-4013
K3G 355-AI56 -02
15.8
K3G 355-AI56 -01
18.6
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Technology
Accessories
Depth of screw 12-16 mm
343
Inlet nozzle
p. 550 f.
Electr. connection
p. 607
Contacts
Cable gland
EC-SYSTEMS
EC centrifugal,
forward
Inlet nozzle (long)
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1460
350
4.20
-25 to +60
K1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
600
2,4
500
2,0
700
2,8
800
400
1,6
4
1,2
200
0,8
100
0,4
3
300
2
0
500
500
344
1000
1000
1500
1
2000
1500
2000
2500
3000
3500
[CFM]
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1460
299
3.60
73
—
A
2
1415
346
4.10
66
58
A
3
1415
350
4.20
62
70
A
4
1465
298
3.60
66
60
General
information
AC centrifugal,
backward
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AD42 -81
6.1
54476-2-4013
K3G 400-AD42 -82
10.7
K3G 400-AD42 -81
9.9
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
246,4±3
197,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
345
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1460
360
2.20
-25 to +60
K1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
500
2,0
600
4
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1460
302
1.85
72
—
A
2
1425
344
2.10
67
48
A
3
1420
360
2.20
63
67
A
4
1460
309
1.90
67
55
A
5
1270
195
1.20
68
—
A
6
1270
235
1.40
64
53
A
7
1270
250
1.50
61
67
A
8
1270
205
1.30
63
54
A
9
900
74
0.50
60
—
A
10
900
90
0.60
56
53
A
11
900
90
0.60
52
67
A
12
900
77
0.50
44
54
1,5
400
8
3
300
1,0
7
200
12
2
6
0,5
11
100
10
5
9
0
500
500
346
1000
1500
1000
1500
2000
2500
3000
1
2000
3500
[CFM]
[m3/h]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AD32 -71
6.1
54476-2-4013
K3G 400-AD32 -72
10.7
K3G 400-AD32 -71
9.9
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, CCC; VDE, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
246,4±3
197,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
347
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1320
325
3.90
-25 to +60
K1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
1,5
400
4
300
1,0
3
200
0,5
2
100
0
500
500
348
1000
1000
1500
1500
2000
2500
2000
3000
3500
1
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1320
275
3.40
72
—
A
2
1275
317
3.80
66
60
A
3
1285
325
3.90
63
70
A
4
1320
285
3.50
66
57
A
600
n
[rpm]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AC42 -81
6.2
54476-2-4013
K3G 400-AC42 -82
11.0
K3G 400-AC42 -81
10.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
269,4±3
220,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
349
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Electr. connection
A
Perm. amb. temp.
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1365
355
2.20
-25 to +60
K1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
400
1,5
4
300
1,0
3
7
2
0,5
12
100
11
6
10
500
500
350
1000
1000
1500
1500
2000
1
5
9
0
2500
2000
3000
3500
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1365
306
1.90
72
—
A
2
1335
339
2.05
70
48
A
3
1320
355
2.20
65
64
A
4
1350
324
2.00
68
54
A
5
1080
152
0.95
67
—
A
6
1080
180
1.10
63
48
A
7
1080
195
1.20
60
64
A
8
1080
165
1.00
61
54
A
9
790
59
0.35
60
—
A
10
790
70
0.45
56
48
A
11
790
76
0.45
52
64
A
12
790
65
0.40
53
54
8
200
n
[rpm]
A
A
2,0
500
[in H O]
Curves
General
information
AC centrifugal,
backward
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AC28 -71
6.2
54476-2-4013
K3G 400-AC28 -72
11.0
K3G 400-AC28 -71
10.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
269,4±3
220,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
351
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1400
380
4.50
-25 to +40
K1)
1~ 100-130
A
(1) Nominal data in operating point with maximum load and 115 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
4
1,5
400
3
1,0
300
2
0,5
200
100
1
0
500
500
352
1000
1000
1500
1500
2000
2500
2000
3000
3500
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1400
328
3.90
74
—
A
2
1360
381
4.50
68
59
A
3
1365
380
4.50
65
68
A
4
1420
317
3.80
69
55
A
600
n
[rpm]
General
information
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AC15 -81
6.2
54476-2-4013
K3G 400-AC15 -82
11.0
K3G 400-AC15 -81
10.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
269,4±3
220,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
353
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
1410
410
2.50
-25 to +40
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
4
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1410
359
2.20
74
—
A
2
1370
401
2.45
69
51
A
3
1375
410
2.50
66
64
A
4
1420
352
2.15
71
54
A
5
1110
161
1.00
68
—
A
6
1110
120
0.80
63
51
A
7
1110
194
1.20
59
64
A
8
1110
151
1.00
61
54
A
9
800
69
0.50
60
—
A
10
800
80
0.50
56
51
A
11
800
78
0.50
52
64
A
12
800
55
0.40
53
54
A
600
n
[rpm]
1,5
400
3
300
1,0
8
7
200
2
0,5
12
6
11
100
10
5
9
0
500
500
354
1000
1000
1500
1500
2000
2500
2000
3000
3500
1
[CFM]
[m3/h]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AC32 -71
6.2
54476-2-4013
K3G 400-AC32 -72
11.0
K3G 400-AC32 -71
10.0
EC centrifugal, backward for clean rooms
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
269,4±3
220,9
2,5
560±2
!
!
ION
s
min!
5
teur
ges! time
ensa
e
ses! cond
volta
us harg ereu
des
gero r disc
dang arge
Dan acito
ions dech
Cap
Tens de
ps
Tem
NT
Technology
TE
ING
AT
RN
WA
409±1
5
tes!
minu
6,4±0,2
8
85
1000±50
520±0,5
355
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
48,5
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Electr. connection
A
Perm. amb. temp.
M3G 112-EA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1720
0.76
3.40
-25 to +60
L1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
4
500
2,0
600
3
8
7
1,0
300
2
12
200
6
0,5
11
100
10
9
0
500
1000
356
1000
1500
2000
5
2000
3000
2500
4000
1
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1720
0.60
2.70
84
—
A
2
1725
0.72
3.20
80
51
A
3
1720
0.76
3.40
75
62
A
4
1725
0.68
3.00
79
59
A
5
1455
0.35
1.60
79
—
A
6
1430
0.39
1.80
74
54
A
7
1425
0.40
1.80
71
69
A
8
1435
0.37
1.70
73
62
A
9
1045
0.15
0.70
68
—
A
10
1030
0.16
0.70
65
60
A
11
1030
0.16
0.80
63
74
A
12
1040
0.15
0.70
64
67
1,5
400
P1
[kW]
A
A
700
n
[rpm]
General
information
AC centrifugal,
backward
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AM56 -11
7.7
54476-2-4013
K3G 400-AM56 -12
16.2
K3G 400-AM56 -11
19.0
EC centrifugal, backward for clean rooms
kg
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
357
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1755
0.77
2.60
-25 to +60
L2)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
4
500
2,0
600
8
3
7
300
1,0
12
2
200
6
0,5
11
10
100
9
0
500
1000
358
1000
1500
2000
2000
3000
5
2500
4000
1
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1755
0.63
2.20
84
—
A
2
1760
0.75
2.50
80
51
A
3
1760
0.77
2.60
75
62
A
4
1760
0.72
2.40
79
56
A
5
1510
0.40
1.60
80
—
A
6
1470
0.42
1.60
74
54
A
7
1465
0.43
1.60
72
69
A
8
1485
0.41
1.60
74
65
A
9
1100
0.17
0.80
70
—
A
10
1090
0.18
0.80
65
62
A
11
1085
0.18
0.80
64
78
A
12
1095
0.18
0.80
66
71
1,5
400
P1
[kW]
A
A
700
n
[rpm]
General
information
AC centrifugal,
backward
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AM61 -06
7.7
54476-2-4013
K3G 400-AM61 -07
16.2
K3G 400-AM61 -06
19.0
EC centrifugal, backward for clean rooms
kg
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
359
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 400
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1755
0.77
1.30
-25 to +60
L2)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,5
4
500
2,0
600
8
3
7
300
1,0
12
2
200
6
0,5
11
10
100
9
0
500
1000
360
1000
1500
2000
2000
3000
5
2500
4000
1
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1755
0.63
1.10
84
—
A
2
1760
0.75
1.30
80
51
A
3
1760
0.77
1.30
75
62
A
4
1760
0.72
1.20
79
56
A
5
1510
0.40
0.80
80
—
A
6
1470
0.42
0.80
74
54
A
7
1465
0.43
0.80
72
69
A
8
1485
0.41
0.80
74
65
A
9
1100
0.17
0.40
70
—
A
10
1090
0.18
0.40
65
62
A
11
1085
0.18
0.40
64
78
A
12
1095
0.18
0.40
66
71
1,5
400
P1
[kW]
A
A
700
n
[rpm]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
R3G 400-AM55 -01
7.7
54476-2-4013
K3G 400-AM55 -02
16.2
K3G 400-AM55 -01
19.0
EC centrifugal,
backward
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
EC centrifugal, backward for clean rooms
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
361
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 450
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1365
0.64
2.90
-25 to +60
L1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
1,5
3
300
7
2
200
0,5
12
6
11
100
10
0
1000
362
9
2000
1000
2000
3000
1
5
3000
4000
5000
[CFM]
6000
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1365
0.48
2.20
80
—
2
1345
0.60
2.70
75
57
A
3
1330
0.64
2.90
71
66
A
4
1340
0.62
2.80
73
60
A
5
1065
0.23
1.10
74
—
A
6
1065
0.29
1.40
68
58
A
7
1055
0.32
1.50
66
66
A
8
1060
0.30
1.40
67
61
A
9
760
0.10
0.50
65
—
A
10
760
0.12
0.60
59
57
A
11
760
0.13
0.60
58
68
A
12
760
0.12
0.60
59
63
1,0
8
P1
[kW]
A
4
400
n
[rpm]
A
A
2,0
500
[in H O]
Curves
12.1
AC centrifugal,
forward
AC centrifugal,
backward
General
information
R3G 450-AG33 -11
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AG33 -12
22.2
K3G 450-AG33 -11
26.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
363
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 450
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1560
1.01
3.20
-25 to +60
L2)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
2
[Pa]
2,5 [in H O]
Curves
4
2,0
500
3
8
1,5
300
1,0
2
12
200
6
0,5
11
10
100
9
0
1000
1000
364
2000
3000
4000
1
5
3000
2000
5000
[CFM]
6000
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1560
0.69
2.30
83
—
A
2
1555
0.91
2.90
78
58
A
3
1555
1.01
3.20
74
67
A
4
1560
0.96
3.10
77
60
A
5
1345
0.43
1.60
80
—
A
6
1315
0.53
2.00
73
60
A
7
1300
0.58
2.00
70
71
A
8
1315
0.54
1.90
72
62
A
9
985
0.19
0.80
71
—
A
10
970
0.22
0.90
65
62
A
11
965
0.25
1.00
62
75
A
12
970
0.23
0.90
64
67
400
7
P1
[kW]
A
A
600
n
[rpm]
12.1
AC centrifugal,
forward
AC centrifugal,
backward
General
information
R3G 450-AG38 -06
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AG38 -07
22.2
K3G 450-AG38 -06
26.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
365
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 450
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1560
1.01
1.60
-25 to +60
L2)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
2
[Pa]
2,5 [in H O]
Curves
4
2,0
500
3
8
1,5
300
1,0
2
12
200
6
0,5
11
10
100
9
0
1000
1000
366
2000
3000
4000
1
5
3000
2000
5000
[CFM]
6000
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1560
0.69
1.10
83
—
A
2
1555
0.91
1.50
78
58
A
3
1555
1.01
1.60
74
67
A
4
1560
0.96
1.50
77
60
A
5
1345
0.43
0.80
80
—
A
6
1315
0.53
1.00
73
60
A
7
1300
0.58
1.00
70
71
A
8
1315
0.54
1.00
72
62
A
9
985
0.19
0.40
71
—
A
10
970
0.22
0.50
65
62
A
11
965
0.25
0.50
62
75
A
12
970
0.23
0.50
64
67
400
7
P1
[kW]
A
A
600
n
[rpm]
12.1
AC centrifugal,
forward
AC centrifugal,
backward
General
information
R3G 450-AG33 -01
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AG33 -02
22.2
K3G 450-AG33 -01
26.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC-SYSTEMS
EC centrifugal,
forward
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Mass of centrifugal
module with support
bracket
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
Depth of screw 12-16 mm
367
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 450
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
2165
2.63
9.80
-25 to +50
M)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
1200
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2165
1.85
6.60
83
—
A
2
2165
2.33
8.70
81
51
A
3
2165
2.59
9.80
78
68
A
4
2165
2.57
9.80
79
64
A
5
1900
1.25
4.30
79
—
A
6
1900
1.59
5.90
77
52
A
7
1900
1.74
6.60
75
68
A
8
1900
1.74
6.60
75
64
A
9
1600
0.75
2.60
71
—
A
10
1600
0.95
3.50
72
52
A
11
1600
1.04
3.90
70
68
A
12
1600
1.04
3.90
71
64
1000
4,0
4
8
3
3,0
800
7
600
2,0
12
11
2
400
1,0
6
10
200
0
1000
2000
368
2000
9
4000
3000
4000
6000
5
5000
8000
1
[CFM]
[m3/h]
21.0
AC centrifugal,
backward
General
information
R3G 450-AT14 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AT14 -20
36.5
K3G 450-AT14 -13
38.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
369
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 450
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
2165
2.63
4.90
-25 to +50
M)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
1200
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2165
1.85
3.30
83
—
A
2
2165
2.33
4.40
81
51
A
3
2165
2.59
4.90
78
68
A
4
2165
2.57
4.90
79
64
A
5
1900
1.25
2.20
79
—
A
6
1900
1.59
3.00
77
52
A
7
1900
1.74
3.30
75
68
A
8
1900
1.74
3.30
75
64
A
9
1600
0.75
1.30
71
—
A
10
1600
0.95
1.80
72
52
A
11
1600
1.04
2.00
70
68
A
12
1600
1.04
2.00
71
64
1000
4,0
4
8
3
3,0
800
7
600
2,0
12
11
2
400
1,0
6
10
200
0
1000
2000
370
2000
9
4000
3000
4000
6000
5
5000
8000
1
[CFM]
[m3/h]
21.0
AC centrifugal,
backward
General
information
R3G 450-AT09 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AT09 -10
36.5
K3G 450-AT09 -03
38.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
371
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fan
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 605
50/60
810
265
1.60
-25 to +40
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
200
0,75
0,50
3
100
2
0,25
12
11
6
50
10
9
0
1000
1000
372
2000
3000
1
5
3000
2000
4000
5000
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
810
211
1.30
72
—
2
765
244
1.50
63
56
A
3
750
265
1.60
59
61
A
4
780
232
1.40
61
49
A
5
645
100
0.70
65
14
A
6
635
130
0.80
58
57
A
7
625
137
0.90
55
63
A
8
650
115
0.80
58
50
A
9
465
42
0.30
56
14
A
10
475
58
0.40
51
59
A
11
475
64
0.40
48
66
A
12
485
52
0.40
52
49
8
7
P1
[W]
A
4
150
n
[rpm]
A
A
1,00
250
[in H O]
Curves
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
R3G 500-AR34 -71
8.8
63072-2-4013
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
373
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 605
Contacts
Technology
Accessories
Core-end sleeves
EC centrifugal fans and modules
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1125
0.71
3.20
-25 to +60
L1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
300
1,25
350
200
8
0,75
250
1,00
3
2
0,50
12
6
100
0,25
11
10
50
9
0
1000
1000
374
2000
2000
3000
5
3000
4000
5000
1
4000
6000
7000
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1125
0.54
2.40
81
—
A
2
1110
0.66
3.00
74
59
A
3
1100
0.71
3.20
70
69
A
4
1110
0.69
3.10
70
66
A
5
920
0.29
1.30
75
—
A
6
905
0.35
1.60
69
64
A
7
900
0.37
1.60
68
75
A
8
900
0.36
1.60
68
75
A
9
665
0.12
0.60
66
—
A
10
650
0.12
0.70
60
65
A
11
650
0.13
0.70
58
78
A
12
655
0.14
0.70
57
82
7
150
P1
[kW]
A
A
4
n
[rpm]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Centrifugal module
with support plate
kg
63072-2-4013
K3G 500-AF32 -12
24.3
K3G 500-AF32 -11
28.0
EC centrifugal,
backward
EC-SYSTEMS
EC centrifugal,
forward
kg
Depth of screw 12-16 mm
Cable gland
Accessories
13.5
Centrifugal module
w. support bracket
Technology
R3G 500-AF32 -11
Inlet nozzle
(long)
375
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
kg
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC centrifugal, backward for clean rooms
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC centrifugal fans and modules
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1160
0.82
2.90
-25 to +60
L2)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
3
1,0
8
7
200
2
12
0,5
6
11
100
10
0
1000
1000
376
2000
9
3000
2000
3000
4000
5000
5
4000
6000
7000
1
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1160
0.57
2.10
83
—
A
2
1160
0.74
2.60
75
58
A
3
1160
0.82
2.90
72
69
A
4
1160
0.76
2.70
71
66
A
5
1005
0.36
1.50
78
—
A
6
980
0.43
1.70
71
63
A
7
970
0.45
1.80
68
76
A
8
980
0.43
1.70
67
70
A
9
735
0.15
0.70
69
—
A
10
725
0.18
0.80
62
69
A
11
720
0.20
0.90
60
82
A
12
720
0.19
0.80
59
76
400
300
P1
[kW]
A
A
4
n
[rpm]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Centrifugal module
with support plate
kg
63072-2-4013
K3G 500-AF39 -07
24.3
K3G 500-AF39 -06
28.0
EC centrifugal,
backward
EC-SYSTEMS
EC centrifugal,
forward
kg
Depth of screw 12-16 mm
Cable gland
Accessories
13.5
Centrifugal module
w. support bracket
Technology
R3G 500-AF39 -06
Inlet nozzle
(long)
377
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC centrifugal, backward for clean rooms
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC centrifugal fans and modules
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
1160
0.82
1.50
-25 to +60
L2)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
1,5
3
1,0
8
7
200
2
12
0,5
6
11
100
10
0
1000
1000
378
2000
9
3000
2000
3000
4000
5000
5
4000
6000
7000
1
[CFM]
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
1160
0.57
1.10
83
—
A
2
1160
0.74
1.30
75
58
A
3
1160
0.82
1.50
72
69
A
4
1160
0.76
1.40
71
66
A
5
1005
0.36
0.70
78
—
A
6
980
0.43
0.90
71
63
A
7
970
0.45
0.90
68
76
A
8
980
0.43
0.80
67
70
A
9
735
0.15
0.40
69
—
A
10
725
0.18
0.40
62
69
A
11
720
0.20
0.40
60
82
A
12
720
0.19
0.40
59
76
400
300
P1
[kW]
A
A
4
n
[rpm]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Centrifugal module
with support plate
kg
63072-2-4013
K3G 500-AF34 -02
24.3
K3G 500-AF34 -01
28.0
EC centrifugal,
backward
EC-SYSTEMS
EC centrifugal,
forward
kg
Depth of screw 12-16 mm
Cable gland
Accessories
13.5
Centrifugal module
w. support bracket
Technology
R3G 500-AF34 -01
Inlet nozzle
(long)
379
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
EC centrifugal, backward for clean rooms
Mass of centrifugal
module with support
bracket
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
Mass of centrifugal
module with support
plate
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC centrifugal fans and modules
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1700
2.80
8.50
-25 to +50
M)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
[Pa]
Curves
4,0
1000
A
3,0
3
8
600
2,0
7
2
400
6
12
1,0
11
200
10
9
0
1000
2000
380
2000
4000
3000
4000
6000
5
5000
8000
1
6000
10000
[CFM]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1700
1.85
5.80
82
—
A
2
1700
2.50
7.80
79
57
A
3
1700
2.65
8.20
78
65
A
4
1700
2.40
7.20
77
58
A
5
1500
1.30
4.20
78
—
A
6
1500
1.70
5.20
75
60
A
7
1500
1.75
5.40
74
65
A
8
1500
1.65
5.20
74
61
A
9
1100
0.57
2.20
69
—
A
10
1100
0.70
2.60
67
56
A
11
1100
0.75
2.60
66
63
A
12
1100
0.70
2.60
65
56
4
800
n
[rpm]
22.0
AC centrifugal,
backward
General
information
R3G 500-AG10 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63072-2-4013
K3G 500-AG10 -20
38.5
K3G 500-AG10 -13
41.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
381
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 500
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 500
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1700
2.70
4.30
-25 to +60
M)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
[Pa]
Curves
4,0
1000
A
3,0
3
8
600
2,0
7
2
400
6
12
1,0
11
200
10
9
0
1000
2000
382
2000
4000
3000
4000
6000
5
5000
8000
1
6000
10000
[CFM]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1700
1.85
2.90
82
—
A
2
1700
2.50
3.90
79
57
A
3
1700
2.65
4.10
78
65
A
4
1700
2.40
3.60
77
58
A
5
1500
1.30
2.10
78
—
A
6
1500
1.70
2.60
75
60
A
7
1500
1.75
2.70
74
65
A
8
1500
1.65
2.60
74
61
A
9
1100
0.57
1.10
69
—
A
10
1100
0.70
1.30
67
56
A
11
1100
0.75
1.30
66
63
A
12
1100
0.70
1.30
65
56
4
800
n
[rpm]
22.0
AC centrifugal,
backward
General
information
R3G 500-AG06 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63072-2-4013
K3G 500-AG06 -10
38.5
K3G 500-AG06 -03
41.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
383
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fan
backward curved, 3-D, Ø 560
Electr. connection
A
Perm. amb. temp.
M3G 112-GA
Max. current
draw (1)
*3G 560
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
945
0.79
3.50
-25 to +60
L1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
1,25
300
4
200
8
0,75
250
1,00
3
0,50
100
6
12
0,25
11
50
10
9
0
1000
2000
384
2000
5
4000
3000
4000
6000
1
[CFM]
8000
[m3/h]
I
[A]
LwA
[dB(A)]
tL
[%]
1
945
0.47
2.20
74
—
A
2
945
0.69
3.10
71
70
A
3
945
0.79
3.50
70
74
A
4
945
0.71
3.20
71
66
A
5
760
0.24
1.20
69
46
A
6
735
0.31
1.40
67
77
A
7
725
0.34
1.60
68
81
A
8
740
0.31
1.40
64
64
A
9
520
0.09
0.50
72
50
A
10
505
0.11
0.60
60
82
A
11
500
0.12
0.60
54
85
A
12
505
0.11
0.60
54
71
2
7
150
P1
[kW]
A
A
350
n
[rpm]
General
information
Mass of
centrifugal fan
EC centrifugal, backward for clean rooms
EC centrifugal,
forward
63071-2-4013
EC-SYSTEMS
13.9
Depth of screw 12-16 mm
Cable gland
Accessories
R3G 560-AK32 -11
Inlet nozzle
(long)
Technology
kg
385
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Centrifugal fan
AC centrifugal,
backward
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
EC centrifugal,
backward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC centrifugal fans and modules
backward curved, 3-D, Ø 560
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 560
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1350
2.30
7.00
-25 to +55
M)
3~ 200-240
A
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
3,0
800
2,5
600
400
3
7
1,5
500
2,0
8
12
300
1,0
2
6
11
200
0,5
10
100
9
0
2000
3000
386
5
4000
6000
1
6000
9000
[CFM]
12000
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1350
1.33
4.40
78
—
A
2
1350
1.90
5.80
77
60
A
3
1350
2.15
6.80
74
68
A
4
1350
2.10
4.40
74
63
A
5
1200
0.90
3.20
75
—
A
6
1200
1.30
4.20
73
60
A
7
1200
1.55
5.00
71
68
A
8
1200
1.43
4.60
71
62
A
9
910
0.45
1.80
67
—
A
10
910
0.60
2.20
65
60
A
11
910
0.70
2.40
64
65
A
12
910
0.65
2.40
64
63
4
700
n
[rpm]
23.5
AC centrifugal,
backward
General
information
R3G 560-AG11 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63071-2-4013
K3G 560-AG11 -20
45.5
K3G 560-AG11 -13
48.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
387
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 560
Perm. amb. temp.
Electr. connection
M3G 150-FF
Max. current
draw (1)
*3G 560
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1350
2.30
3.60
-25 to +60
M)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
3,0
800
2,5
600
400
3
7
1,5
500
2,0
8
12
300
1,0
2
6
11
200
0,5
10
100
9
0
2000
3000
388
5
4000
6000
1
6000
9000
[CFM]
12000
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1350
1.33
2.20
78
—
A
2
1350
1.90
2.90
77
60
A
3
1350
2.15
3.40
74
68
A
4
1350
2.10
2.20
74
63
A
5
1200
0.90
1.60
75
—
A
6
1200
1.30
2.10
73
60
A
7
1200
1.55
2.50
71
68
A
8
1200
1.43
2.30
71
62
A
9
910
0.45
0.90
67
—
A
10
910
0.60
1.10
65
60
A
11
910
0.70
1.20
64
65
A
12
910
0.65
1.20
64
63
4
700
n
[rpm]
23.5
AC centrifugal,
backward
General
information
R3G 560-AG07 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63071-2-4013
K3G 560-AG07 -10
45.5
K3G 560-AG07 -03
48.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
389
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 560
Electr. connection
A
Perm. amb. temp.
M3G 150-IF
Max. current
draw (1)
*3G 560
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1510
2.90
9.20
-25 to +45
M)
3~ 200-240
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
2
4,0
[Pa]
A
3,5
1000
[in H O]
Curves
4
2,5
3,0
800
600
2,0
7
1,5
400
2
1,0
12
6
11
0,5
200
10
9
0
2000
4000
390
4000
1
5
6000
8000
8000
12000
[CFM]
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1510
1.90
6.00
81
—
A
2
1510
2.47
7.60
80
52
A
3
1510
3.05
9.20
77
67
A
4
1510
2.85
8.80
76
64
A
5
1200
0.90
3.20
75
—
A
6
1200
1.30
4.20
73
60
A
7
1200
1.55
5.00
71
68
A
8
1200
1.43
4.60
71
62
A
9
910
0.45
1.80
67
—
A
10
910
0.60
2.20
65
60
A
11
910
0.70
2.40
64
65
A
12
910
0.65
2.40
64
63
3
8
n
[rpm]
27.5
AC centrifugal,
backward
General
information
R3G 560-AH07 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63071-2-4013
K3G 560-AH07 -20
49.5
K3G 560-AH07 -13
52.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
391
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 560
Electr. connection
A
Perm. amb. temp.
M3G 150-IF
Max. current
draw (1)
*3G 560
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1510
3.10
4.90
-25 to +60
M)
3~ 380-480
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
2
4,0
[Pa]
A
3,5
1000
[in H O]
Curves
4
2,5
3,0
800
600
2,0
7
1,5
400
2
1,0
12
6
11
0,5
200
10
9
0
2000
4000
392
4000
1
5
6000
8000
8000
12000
[CFM]
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1510
1.90
3.00
81
—
A
2
1510
2.47
3.80
80
52
A
3
1510
3.05
4.60
77
67
A
4
1510
2.85
4.40
76
64
A
5
1200
0.90
1.60
75
—
A
6
1200
1.30
2.10
73
60
A
7
1200
1.55
2.50
71
68
A
8
1200
1.43
2.30
71
62
A
9
910
0.45
0.90
67
—
A
10
910
0.60
1.10
65
60
A
11
910
0.70
1.20
64
65
A
12
910
0.65
1.20
64
63
3
8
n
[rpm]
27.5
AC centrifugal,
backward
General
information
R3G 560-AH02 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63071-2-4013
K3G 560-AH02 -10
49.5
K3G 560-AH02 -03
52.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
393
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fan
backward curved, 3-D, Ø 630
Perm. amb. temp.
Electr. connection
M3G 112-GA
Max. current
draw (1)
*3G 630
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 607
50/60
685
0.53
1.00
-25 to +60
L2)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
2
[Pa]
4
0,75
200
3
150
0,50
8
7
100
2
0,25
12
6
11
50
10
9
0
1000
2000
394
2000
3000
4000
4000
6000
5
5000
8000
1
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
tL
[%]
A
1
685
0.38
0.70
73
—
A
2
685
0.47
0.90
67
57
A
3
685
0.53
1.00
65
68
A
4
685
0.48
0.90
64
61
A
5
560
0.21
0.40
67
—
A
6
545
0.23
0.50
61
61
A
7
540
0.26
0.50
59
71
A
8
550
0.24
0.50
58
65
A
9
390
0.08
0.20
56
—
A
10
385
0.09
0.20
52
63
A
11
380
0.10
0.30
51
75
A
12
390
0.10
0.30
49
66
A
1,00
250
[in H O]
Curves
General
information
Mass of
centrifugal fan
EC centrifugal, backward for clean rooms
EC centrifugal,
forward
63070-2-4013
EC-SYSTEMS
14.7
Depth of screw 12-16 mm
Cable gland
Accessories
R3G 630-AF36 -01
Inlet nozzle
(long)
Technology
kg
395
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 607
Contacts
Centrifugal fan
AC centrifugal,
backward
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
EC centrifugal,
backward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (passive)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for
EC centrifugal fans and modules
backward curved, 3-D, Ø 630
Electr. connection
A
Perm. amb. temp.
M3G 150-FF
Max. current
draw (1)
*3G 630
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1000
1.70
5.30
-25 to +60
M)
3~ 200-240
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
900
3,0
2,5
400
4
1,5
500
2,0
600
3
1,0
300
8
200
2
0,5
7
100
6
0
2000
4000
396
5
6000
4000
8000
1
8000
12000
10000
16000
[CFM]
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1000
1.10
3.60
74
—
A
2
1000
1.40
4.60
71
54
A
3
1000
1.65
5.00
70
66
A
4
1000
1.70
5.20
70
64
A
5
770
0.50
2.00
66
—
A
6
770
0.65
2.40
64
54
A
7
770
0.73
2.80
64
66
A
8
770
0.77
2.80
64
64
800
700
n
[rpm]
24.5
AC centrifugal,
backward
General
information
R3G 630-AA12 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63070-2-4013
K3G 630-AA12 -20
47.5
K3G 630-AA12 -13
52.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
397
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 630
Electr. connection
A
Perm. amb. temp.
M3G 150-FF
Max. current
draw (1)
*3G 630
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1000
1.70
2.80
-25 to +60
M)
3~ 380-480
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
900
3,0
2,5
400
4
1,5
500
2,0
600
3
1,0
300
8
200
2
0,5
7
100
6
0
2000
4000
398
5
6000
4000
8000
1
8000
12000
10000
16000
[CFM]
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1000
1.10
1.80
74
—
A
2
1000
1.40
2.30
71
54
A
3
1000
1.65
2.50
70
66
A
4
1000
1.70
2.60
70
64
A
5
770
0.50
1.00
66
—
A
6
770
0.65
1.20
64
54
A
7
770
0.73
1.40
64
66
A
8
770
0.77
1.40
64
64
800
700
n
[rpm]
24.5
AC centrifugal,
backward
General
information
R3G 630-AA08 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63070-2-4013
K3G 630-AA08 -10
47.5
K3G 630-AA08 -03
52.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
399
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 630
Electr. connection
A
Perm. amb. temp.
M3G 150-IF
Max. current
draw (1)
*3G 630
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1200
2.80
8.40
-25 to +45
M)
3~ 200-240
(1) Nominal data in operating point with maximum load and 200 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
900
3,0
2,5
600
2,0
8
7
12
1,0
300
2
11
200
6
0,5
10
100
9
0
2000
4000
400
4000
6000
8000
5
8000
12000
1
10000
16000
[CFM]
[m3/h]
LwA
[dB(A)]
tL
[%]
1
1200
1.95
5.90
88
—
2
1200
2.44
7.40
83
52
A
3
1200
2.70
8.20
82
64
A
4
1200
2.80
8.40
82
64
A
5
1050
1.29
4.00
85
—
A
6
1050
1.61
4.80
80
52
A
7
1050
1.78
5.40
79
64
A
8
1050
1.83
5.60
79
64
A
9
900
0.81
2.40
82
—
A
10
900
1.01
3.00
77
52
A
11
900
1.12
3.40
75
64
A
12
900
1.15
3.40
75
64
3
1,5
400
I
[A]
A
4
500
P1
[kW]
A
800
700
n
[rpm]
28.5
AC centrifugal,
backward
General
information
R3G 630-AB10 -13
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63070-2-4013
K3G 630-AB10 -20
51.5
K3G 630-AB10 -13
56.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
401
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
EC centrifugal fans and modules
backward curved, 3-D, Ø 630
Electr. connection
A
Perm. amb. temp.
M3G 150-IF
Max. current
draw (1)
*3G 630
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support bracket: Steel, coated in black
Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 608
50/60
1200
2.80
4.20
-25 to +55
M)
3~ 380-480
(1) Nominal data in operating point with maximum load and 400 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
900
3,0
2,5
600
2,0
8
7
12
1,0
300
2
11
200
6
0,5
10
100
9
0
2000
4000
402
4000
6000
8000
5
8000
12000
1
10000
16000
[CFM]
[m3/h]
LwA
[dB(A)]
tL
[%]
1
1200
1.95
3.00
88
—
2
1200
2.44
3.70
83
52
A
3
1200
2.70
4.10
82
64
A
4
1200
2.80
4.20
82
64
A
5
1050
1.29
2.00
85
—
A
6
1050
1.61
2.40
80
52
A
7
1050
1.78
2.70
79
64
A
8
1050
1.83
2.80
79
64
A
9
900
0.81
1.20
82
—
A
10
900
1.01
1.50
77
52
A
11
900
1.12
1.70
75
64
A
12
900
1.15
1.70
75
64
3
1,5
400
I
[A]
A
4
500
P1
[kW]
A
800
700
n
[rpm]
28.5
AC centrifugal,
backward
General
information
R3G 630-AB06 -03
Inlet nozzle
(long)
Centrifugal module
w. support bracket
kg
Centrifugal module
with support plate
kg
63070-2-4013
K3G 630-AB06 -10
51.5
K3G 630-AB06 -03
56.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
kg
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Mass of centrifugal
module with support
bracket
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 20-25 mm
403
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Electr. connection
p. 608
Contacts
Technology
Accessories
Cable gland
404
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Ø 310 - Ø 450
Technology
EC centrifugal fans with aluminium impeller, line-fed
405
AC centrifugal,
forward
406
Contacts
AC centrifugal,
backward
General
information
EC centrifugal fans for clean rooms backward curved
EC centrifugal fans and modules
backward curved, 3-D, Ø 310, RS485, ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-DF
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
2340
370
1.70
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
3,0
800
700
2,5
2,0
500
3
400
1,5
8
7
300
1,0
200
11
0,5
6
16
100
10
15
14
9
13
0
250
400
406
500
800
750
1200
1000
1600
1
[CFM]
5
1250
2000
2400
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2340
265
1.20
74
—
A
2
2270
335
1.50
71
63
A
3
2240
370
1.70
70
66
A
4
2290
335
1.50
70
48
A
5
1910
160
0.70
69
—
A
6
1910
205
0.90
67
63
A
7
1910
240
1.00
66
66
A
8
1910
205
0.90
66
48
A
9
1410
80
0.40
61
—
A
10
1410
98
0.40
59
63
A
11
1410
112
0.50
58
66
A
12
1410
103
0.50
57
48
A
13
910
40
0.20
50
—
A
14
910
42
0.20
47
63
A
15
910
46
0.20
47
66
A
16
910
44
0.20
48
48
2
12
P1
[W]
A
4
600
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
with support plate
kg
R3G 310-AJ38 -61
4.3
31050-2-4013
31051-2-4013
K3G 310-AJ38 -61
7.1
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
View Y
View X
(1)
(2)
N
RSB
in alarm mode = 0 V
in alarm mode = +15 V
RSA +15V(1) 0 V(2)
407
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Connection lead
p. 559
Electr. connection
p. 606
Contacts
Technology
Accessories
PE L
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 310, RS485, ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
2200
455
2.00
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2,5
600
500
2,0
4
3
8
1,5
400
7
300
I
[A]
LpA
[dB(A)]
tL
[%]
1
2200
345
1.50
73
—
2
2150
430
1.90
70
60
A
3
2130
455
2.00
68
64
A
4
2170
420
1.80
69
54
A
5
1800
200
0.90
68
—
A
6
1800
265
1.20
65
60
A
7
1800
285
1.20
63
64
A
8
1800
260
1.10
64
54
A
9
1400
90
0.40
61
—
A
10
1400
118
0.50
59
60
A
11
1400
128
0.60
57
64
A
12
1400
113
0.50
58
54
A
13
1000
33
0.10
52
—
A
14
1000
44
0.20
48
60
A
15
1000
47
0.20
48
64
A
16
1000
41
0.20
49
54
1,0
2
12
200
6
0,5
11
16
100
10
15
14
13
0
500
500
408
P1
[W]
A
A
700
n
[rpm]
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
1000
9
1000
1500
2000
5
1500
2500
1
[CFM]
3000
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
with support plate
kg
R3G 310-AL28 -61
5.4
31050-2-4013
31051-2-4013
K3G 310-AL28 -61
8.2
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
Inlet nozzle (long)
View Y
View X
(1)
(2)
N
RSB
in alarm mode = 0 V
in alarm mode = +15 V
RSA +15V(1) 0 V(2)
409
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Connection lead
p. 559
Electr. connection
p. 606
Contacts
Technology
Accessories
PE L
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 355, RS485, ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
1840
430
1.90
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2,5
700
600
500
2,0
4
3
8
1,5
400
7
300
1,0
12
2
11
200
6
0,5
16
100
10
15
14
0
500
410
13
1000
500
1000
1500
1500
2000
1
5
9
2500
[CFM]
3000
[m3/h]
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1840
335
1.50
75
—
A
2
1790
405
1.80
70
56
A
3
1770
430
1.90
66
70
A
4
1820
365
1.60
67
58
A
5
1540
200
0.90
70
—
A
6
1540
256
1.10
66
56
A
7
1540
277
1.20
63
70
A
8
1540
235
1.00
63
58
A
9
1260
115
0.50
64
—
A
10
1260
150
0.70
60
56
A
11
1260
159
0.70
56
70
A
12
1260
125
0.50
57
58
A
13
890
55
0.20
55
—
A
14
890
67
0.30
52
56
A
15
890
70
0.30
49
70
A
16
890
59
0.30
49
58
A
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
with support plate
kg
R3G 355-AM14 -61
5.4
35560-2-4013
35561-2-4013
K3G 355-AM14 -61
8.7
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA; CCC, GOST are applied for
Inlet nozzle (long)
View X
(1)
(2)
N
RSB
RSA +15V(1) 0 V(2)
411
Inlet nozzle
p. 550 f.
Connection lead
p. 559
Electr. connection
p. 606
Contacts
Technology
PE L
in alarm mode = 0 V
in alarm mode = +15 V
Accessories
View Y
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 355, RS485, ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
1710
395
1.80
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves (established with long inlet nozzle)
2,0
500
4
1,5
8
1,0
300
12
0,5
16
6
15
10
100
14
13
0
500
500
412
1000
1000
1500
2000
9
1500
2500
1
5
2000
3000
3500
[CFM]
[m3/h]
tL
[%]
1710
305
1.30
72
—
2
1660
375
1.60
67
58
A
3
1650
395
1.80
64
68
A
4
1670
365
1.60
66
57
A
5
1400
166
0.70
65
—
A
6
1400
225
1.00
63
58
A
7
1400
245
1.10
60
68
A
8
1400
216
0.90
61
57
A
9
1200
105
0.50
60
—
A
10
1200
150
0.70
58
58
A
11
1200
172
0.80
56
68
A
12
1200
136
0.60
57
57
A
13
1000
60
0.30
55
—
A
14
1000
82
0.40
53
58
A
15
1000
90
0.40
51
68
A
16
1000
80
0.40
53
57
2
11
LpA
[dB(A)]
1
7
200
I
[A]
A
400
3
P1
[W]
A
A
600
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Inlet nozzle
(short)
Centrifugal module
with support plate
kg
R3G 355-AN31 -61
5.5
35560-2-4013
35561-2-4013
K3G 355-AN31 -61
8.9
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: VDE, UL, CSA; CCC, GOST are applied for
Inlet nozzle (long)
View X
(1)
(2)
N
RSB
RSA +15V(1) 0 V(2)
413
Inlet nozzle
p. 550 f.
Connection lead
p. 559
Electr. connection
p. 606
Contacts
Technology
PE L
in alarm mode = 0 V
in alarm mode = +15 V
Accessories
View Y
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 400, RS485 ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
1470
370
1.65
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
2
[Pa]
[in H O]
Curves
2,0
500
4
1,5
3
1,0
300
7
200
12
0,5
2
11
6
100
10
9
0
500
500
414
1000
1000
1500
5
1500
2000
2500
3000
1
2000
3500
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1470
323
1.45
73
—
A
2
1430
362
1.60
69
53
A
3
1420
370
1.65
64
68
A
4
1470
319
1.40
66
52
A
5
1300
210
0.90
71
—
A
6
1300
255
1.10
65
53
A
7
1300
270
1.20
61
68
A
8
1300
230
1.00
64
52
A
9
910
90
0.40
61
—
A
10
910
100
0.40
57
53
A
11
910
108
0.50
53
68
A
12
910
92
0.40
51
52
400
8
P1
[W]
A
A
600
n
[rpm]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Centrifugal module
with support plate
kg
R3G 400-AD27 -61
5.8
54476-2-4013
K3G 400-AD27 -61
9.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
View X
(1)
(2)
N
RSB
RSA +15V(1) 0 V(2)
Connection lead
p. 559
Electr. connection
p. 606
415
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Contacts
Technology
PE L
in alarm mode = 0 V
in alarm mode = +15 V
Accessories
View Y
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 400, RS485 ebmBUS
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
*3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Sheet aluminium, spacer profiles: Aluminium
Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
°C
p. 606
50/60
1420
380
1.70
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
500
2,0
600
4
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1420
327
1.45
73
—
A
2
1395
355
1.55
71
40
A
3
1370
380
1.70
66
64
A
4
1415
333
1.45
69
54
A
5
1120
187
0.80
68
—
A
6
1120
207
0.90
65
40
A
7
1120
225
1.00
60
64
A
8
1120
173
0.80
61
54
A
9
800
85
0.40
60
—
A
10
800
92
0.40
58
40
A
11
800
97
0.40
53
64
A
12
800
85
0.40
54
54
A
2
[Pa]
[in H O]
Curves
1,5
400
3
300
1,0
8
7
200
0,5
12
2
11
100
6
10
500
500
416
1000
1000
1500
1500
2000
1
5
9
0
2500
2000
3000
3500
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Inlet nozzle
(long)
Centrifugal module
with support plate
kg
R3G 400-AC30 -61
5.9
54476-2-4013
K3G 400-AC30 -61
9.9
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of centrifugal
module with support
plate
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; VDE, CCC, GOST are applied for
View X
(1)
(2)
N
RSB
RSA +15V(1) 0 V(2)
Connection lead
p. 559
Electr. connection
p. 606
417
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Contacts
Technology
PE L
in alarm mode = 0 V
in alarm mode = +15 V
Accessories
View Y
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
EC centrifugal fans and modules
backward curved, 3-D, Ø 450, RS485, ebmBUS
Perm. amb. temp.
Electr. connection
M3G 112-EA
Max. current
draw (1)
*3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Support plate: Galvanised sheet steel, spacer profiles: Aluminium
Impeller: Sheet aluminium, laser-welded
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
°C
p. 606
50/60
1225
0.50
2.20
-25 to +40
K2)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
subject to alterations
A
2
[Pa]
[in H O]
Curves
400
4
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1225
0.35
1.50
68
—
A
2
1225
0.49
2.10
64
65
A
3
1225
0.50
2.20
64
67
A
4
1225
0.47
2.10
63
62
A
5
1000
0.19
0.80
63
—
A
6
1000
0.26
1.20
59
65
A
7
1000
0.28
1.20
59
67
A
8
1000
0.26
1.10
57
62
A
9
700
0.07
0.30
55
—
A
10
700
0.09
0.40
49
65
A
11
700
0.10
0.40
49
67
A
12
700
0.09
0.40
48
62
3
1,2
300
n
[rpm]
8
7
0,8
200
2
6
100
0,4
12
11
10
5
9
0
1000
1000
418
2000
2000
3000
1
3000
4000
5000
[CFM]
[m3/h]
General
information
11.5
Centrifugal module
with support plate
kg
63045-2-4013
K3G 450-AO51 -01
25.4
AC centrifugal,
forward
EC centrifugal, backward for clean rooms
R3G 450-AO51 -01
Inlet nozzle
(long)
Depth of screw
12-16 mm
View X
(1)
(2)
PE L
15
N
RSB
RSA +15V(1) 0 V(2)
Connection lead
p. 559
Electr. connection
p. 606
630-1
500-1
Technology
8xØ11
Ø284,5
4xØ9
15
580±0,5
419
Inlet nozzle
p. 550 f.
Guard grille
p. 553
Contacts
360
120
2,5
30
353,5
294,5
in alarm mode = 0 V
in alarm mode = +15 V
Accessories
View Y
EC-SYSTEMS
EC centrifugal,
forward
kg
EC centrifugal,
backward
Mass of centrifugal
module with support
plate
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
– Technical features:
• Operation and alarm display: Reversible voltage output 0 V / +15 V (max. 50 mA)
• PFC (active)
• Over-temperature protected electronics / motor
• RS485 ebmBUS
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Electrical connection: Via connection lead with plug (accessory)
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, VDE, CCC, GOST are applied for
420
General
information
422
EC centrifugal fans and blowers, single inlet, line-fed
Ø 108 - Ø 450
438
EC centrifugal blowers, dual inlet, 24 / 48 VDC
Ø 133 - Ø 160
502
EC centrifugal blowers, dual inlet, line-fed
Ø 146 - Ø 180
510
AC centrifugal,
backward
Ø 085 - Ø 160
421
Contacts
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
EC centrifugal fans and blowers, single inlet, 24 / 48 VDC
AC centrifugal,
forward
EC centrifugal fans and blowers forward curved
EC centrifugal fans and blowers
single inlet, Ø 085
M1G 045-BE
A
48
rpm
W
A
dB(A)
16-28
95
2850
14
0.64
57
36-57
95
2850
14
0.32
57
Electr. connection
*1G 085
m3/h
Perm. amb. temp.
24
VDC
Min. back pressure
A
Sound pressure level
M1G 045-BE
Current draw
*1G 085
Power input
Motor
Speed/rpm
Type
Air flow
Nominal data
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
240
UR
4'
0,8
200
4
0,6
UN
3'
0,4
3
80
8
0,2
2'
2
7
40
6
1
5
0
10
20
20
422
30
40
40
60
50
80
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
3180
19
59
—
A
2’
3300
16
57
28
A
3’
3500
15
57
32
A
4’
3800
12
57
37
A
1
2850
14
57
—
A
2
3000
12
55
28
A
3
3180
11
55
32
A
4
3400
9
54
37
A
5
1890
5
46
—
A
6
1970
4
44
25
A
7
2070
4
44
30
A
8
2170
3
42
33
160
120
n
[rpm]
General
information
AC centrifugal,
backward
• Tach output
• Reverse polarity and locked-rotor protection
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 085-AB05 -01
0.5
G1G 085-AB05 -01
0.8
R1G 085-AB07 -01
0.5
G1G 085-AB07 -01
0.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
– Technical features:
• Control input 0-10 VDC / PWM
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (48 VDC) CCC
Depth of screw
max. 4 mm
68 ±1
EC centrifugal,
forward
45,4 ±1
EC-SYSTEMS
Ø34
6
Ø67
Ø85
Ø59
M4
60
300±20
42
47±0,15
Brass lead tips
76
117,5
3
56
20˚
127,5
Technology
M4
71,5
84
Ø65 -1
39
68
3x1
42
6
60
80
300
423
Inlet nozzle
p. 552
Guard grille
p. 554
Electr. connection
p. 600
Contacts
58
34,5
4,5
5,5
Accessories
60,2
66
EC centrifugal fans and blowers
single inlet, Ø 097
M1G 045-BE
A
48
rpm
W
A
dB(A)
16-28
95
2650
16
0.75
59
36-57
95
2650
16
0.38
59
Electr. connection
*1G 097
m3/h
Perm. amb. temp.
24
VDC
Min. back pressure
A
Sound pressure level
M1G 045-BE
Current draw
*1G 097
Power input
Motor
Speed/rpm
Type
Air flow
Nominal data
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Hot-dip galvanised sheet steel
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
4'
280
1,0
UR
4
200
0,8
240
3'
0,6
160
UN
3
0,4
120
80
8
0,2
2'
7
2
40
6
1
5
0
10
20
424
20
40
30
40
60
50
80
1'
60
100
[CFM]
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2920
22
62
—
A
2’
3030
21
61
41
A
3’
3300
17
59
48
A
4’
3700
13
58
48
A
1
2650
16
59
—
A
2
2730
15
58
41
A
3
2960
13
56
48
A
4
3290
10
55
48
A
5
1615
4
45
—
A
6
1650
4
45
38
A
7
1745
4
43
46
A
8
1880
3
42
47
General
information
AC centrifugal,
backward
• Tach output
• Reverse polarity and locked-rotor protection
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R1G 097-AA05 -01
0.5
G1G 097-AA05 -01
0.8
R1G 097-AA07 -01
0.5
G1G 097-AA07 -01
0.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
– Technical features:
• Control input 0-10 VDC / PWM
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (48 VDC) CCC
Depth of screw
max. 4 mm
33 ±1
EC centrifugal,
forward
49,4 ±1
EC-SYSTEMS
Ø34
Ø59
6
Ø77,5
Ø97
M4
60
300±20
25
47±0,15
Brass lead tips
Accessories
143
75
18
24
3
,5˚
137
3x1
60
20˚
Ø96
Ø80
6
Technology
75
46
56
3
300
425
Inlet nozzle
p. 552
Guard grille
p. 554
Electr. connection
p. 600
Contacts
40
EC centrifugal fans and blowers
single inlet, Ø 108
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 108
M1G 055-BD
A
24
16-28
200
3000
42
2.00
65
*1G 108
M1G 055-BD
A
48
36-57
200
3000
42
1.00
65
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
1,5
400
3'
1,0
UN
8
0,5
7
2'
100
2
6
5
0
20
40
426
40
60
80
80
120
100
140
1
120
180
1'
[CFM]
[m3/h]
tL
[%]
1’
3230
55
67
—
2’
3410
52
66
33
A
3’
3800
43
65
41
A
4’
4100
35
64
33
A
1
3000
42
65
—
A
2
3140
40
64
33
A
3
3420
32
63
41
A
4
3690
26
63
33
A
5
2300
20
61
—
A
6
2380
17
58
33
A
7
2550
14
55
41
A
8
2720
11
55
33
3
200
LpA
[dB(A)]
A
4
300
P1
[W]
A
4'
UR
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 108-AB17 -02
0.7
G1G 108-AB17 -02
1.4
R1G 108-AB41 -02
0.7
G1G 108-AB41 -02
1.4
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC
Depth of screw
max. 6 mm
63 ±1
EC centrifugal,
forward
55 ±1
EC-SYSTEMS
Ø58
6
Ø84
Ø108
Ø72
M4
85
450±20
52
58 ±0,15
Brass lead tips
159
115
97
118
6
Technology
183
50
66
76
Ø87-1
M4
85
71
450±20
82
427
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 600
Contacts
83
8
Accessories
79
EC centrifugal fans and blowers
single inlet, Ø 120
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 120
M1G 055-BD
A
24
16-28
255
2200
40
1.90
62
*1G 120
M1G 055-BD
A
48
36-57
255
2200
40
0.95
62
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
UR
400
1,5
4
1,0
UN
3'
200
3
8
0,5
7
2'
100
2
6
5
0
50
40
428
80
1
150
100
120
160
200
240
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2410
50
63
—
A
2’
2620
47
62
58
A
3’
2870
44
61
60
A
4’
3200
36
62
55
A
1
2200
40
62
—
A
2
2410
36
60
59
A
3
2600
32
58
62
A
4
2880
25
58
55
A
5
1870
24
55
—
A
6
1990
21
54
58
A
7
2100
18
53
61
A
8
2310
14
54
54
4'
300
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 120-AB67 -02
0.8
G1G 120-AB67 -02
1.6
R1G 120-AB71 -02
0.8
G1G 120-AB71 -02
1.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC
Depth of screw
max. 6 mm
83 ±1
EC centrifugal,
forward
55±1
EC-SYSTEMS
Ø58
6
Ø97
Ø120
Ø72
M4
85
450±20
62
58 ±0,15
Brass lead tips
178
115
190
98
50
68
76
Technology
132
Ø100 -1
82
M4
86
6
85
98
450 ±20
429
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 600
Contacts
83
7
Accessories
82
100
EC centrifugal fans and blowers
single inlet, Ø 133
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 133
M1G 055-BD
A
24
16-28
225
2000
40
2.20
64
*1G 133
M1G 055-BD
A
48
36-57
225
2000
45
1.10
64
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Hot-dip galvanised sheet steel
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
4'
1,5
400
4
UR
3'
UN
300
1,0
3
8
200
7
2'
0,5
2
6
100
5
0
40
40
430
80
80
120
1
1'
120
160
200
[CFM]
240
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
2170
57
66
—
A
2’
2410
51
66
47
A
3’
2750
44
64
49
A
4’
3200
36
66
32
A
1
2000
45
64
—
A
2
2230
40
64
49
A
3
2540
35
62
51
A
4
2920
27
63
33
A
5
1750
28
60
—
A
6
1910
24
59
50
A
7
2120
20
58
53
A
8
2370
15
59
35
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R1G 133-AE19 -02
0.7
G1G 133-DE19 -02
1.3
R1G 133-AE03 -02
0.7
G1G 133-DE03 -02
1.3
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Lateral
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC
Depth of screw
max. 6 mm
66 ±1
EC centrifugal,
forward
55±1
EC-SYSTEMS
Ø58
6
Ø108
Ø133
Ø72
M4
85
450±20
46
58 ±0,15
Brass lead tips
171
59
Accessories
87
101
Technology
Ø112
180
45˚
3
71
4x90˚
431
Inlet nozzle
p. 552
Electr. connection
p. 600
Contacts
81
6
85
450±20
140
EC centrifugal fans and blowers
single inlet, Ø 140
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 140
M1G 055-CF
A
24
16-28
400
1750
54
2.50
63
*1G 140
M1G 055-CF
A
48
36-57
410
1750
54
1.30
63
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
300
1,0
3'
UR
3
200
8
7
0,5
2'
2
100
6
0
50
100
432
100
5
200
150
200
300
1
400
1'
250
[CFM]
[m3/h]
LpA
[dB(A)]
tL
[%]
1’
1850
65
64
—
A
2’
2020
61
61
50
A
3’
2200
57
59
54
A
4’
2550
43
60
40
A
1
1750
54
63
—
A
2
1900
50
59
51
A
3
2030
45
58
54
A
4
2310
32
58
40
A
5
1500
34
60
—
A
6
1580
29
56
50
A
7
1670
25
54
53
A
8
1880
19
53
41
4
UN
P1
[W]
A
400
4'
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 140-AV17 -02
1.0
G1G 140-AV17 -02
2.3
R1G 140-AV21 -02
1.0
G1G 140-AV21 -02
2.3
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: A (48 VDC) CCC
Depth of screw
max. 6 mm
72 ±1
EC centrifugal,
forward
68,2 ±1
EC-SYSTEMS
Ø58
6
Ø121
Ø140
Ø72
M4
85
450±20
59
58 ±0,15
Brass lead tips
max. 227,8
Accessories
6,6
103
158
107
M4
6
Technology
450±20
max. 262,6
92
105
94
Ø118-1
85
100 ±1
433
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 600
Contacts
120
130
115
EC centrifugal fans and blowers
single inlet, Ø 146
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 146
M1G 074-BF
A
24
16-28
470
2200
100
5.00
68
*1G 146
M1G 074-BF
A
48
36-57
465
2150
100
2.60
67
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
A
3,0
[Pa]
[in H O]
Curves (established at 24 VDC)
2,5
700
4'
600
400
2,0
UN
3
8
300
1,0
2
12
6
0,5
11
10
100
50
100
434
100
150
200
200
300
1
5
9
0
LpA
[dB(A)]
tL
[%]
1’
2400
140
70
—
A
2’
2650
130
67
45
A
3’
3000
110
66
49
A
4’
3300
100
67
45
A
1
2200
100
68
—
A
2
2445
90
65
46
A
3
2750
84
64
49
A
4
3025
77
65
45
A
5
1890
68
63
—
A
6
2075
57
60
46
A
7
2250
48
61
49
A
8
2335
41
61
45
A
9
1520
37
59
—
A
10
1670
32
55
46
A
11
1815
27
55
49
A
12
1920
23
55
45
2'
7
200
P1
[W]
A
3'
1,5
500
UR
4
n
[rpm]
250
400
1'
300
500
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 146-AA07 -52
1.4
G1G 146-BA07 -52
2.8
R1G 146-AA11 -52
1.4
G1G 146-BA11 -52
2.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA, CCC (centrifugal blower only)
EC centrifugal,
forward
Depth of screw
max. 6 mm
72 ±1
65 ±1
EC-SYSTEMS
6
32,7
Ø92
min. Ø119,5
max. Ø146,5
58
±
0,
15
M4
85
450 +20
max. 62,5
Brass lead tips
450 +20
Accessories
158
108
M4
6
Technology
6,3
103
max. 262,6
Ø125,5-1
max. 227,8
92
94
105
85
100 ±1
435
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 600
Contacts
120
130
115
EC centrifugal fans and blowers
single inlet, Ø 160
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
*1G 160
M1G 074-BF
A
24
16-28
505
1750
105
5.80
67
*1G 160
M1G 074-BF
A
48
36-57
505
1750
105
2.90
67
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
900
3,0
4'
UR
600
2,0
4
500
3'
UN
400
3
8
7
300
1,0
2'
2
200
6
100
5
0
100
100
436
200
200
300
400
1
300
500
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1890
134
68
—
A
2’
2200
118
67
52
A
3’
2500
110
67
57
A
4’
2900
102
69
52
A
1
1750
105
67
—
A
2
2030
95
66
52
A
3
2270
90
65
57
A
4
2550
81
67
44
A
5
1580
72
62
—
A
6
1810
66
62
52
A
7
2000
58
62
57
A
8
2200
48
63
54
800
700
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R1G 160-AH29 -52
1.4
G1G 160-BH29 -52
2.8
R1G 160-AH39 -52
1.4
G1G 160-BH39 -52
2.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Axial
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA
EC centrifugal,
forward
Depth of screw
max. 6 mm
72 ±1
65 ±1
EC-SYSTEMS
6
32,7
Ø92
min. Ø136
max. Ø160,5
58
±
0,
15
M4
85
450 +20
max. 62
Brass lead tips
max. 227,8
130
175
108
M4
6
Technology
max. 262,6
450 +20
Ø130 -1
Accessories
6,3
103
92
94
105
85
100 ±1
437
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 600
Contacts
120
115
EC centrifugal fan and blowers
single inlet, Ø 108
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 108
M3G 055-BD
50/60
2960
60
0.90
subject to alterations
1~ 115
A
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
A
2
[Pa]
[in H O]
Curves
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2960
60
0.90
64
—
A
2
3100
53
0.80
62
42
A
3
3370
42
0.60
60
44
A
4
3560
34
0.50
59
32
A
5
2570
38
0.55
61
—
A
6
2660
34
0.50
60
42
A
7
2820
25
0.40
57
44
A
8
2920
19
0.30
55
32
A
9
2150
23
0.35
56
—
A
10
2200
20
0.30
55
42
A
11
2320
16
0.25
52
44
A
12
2390
12
0.20
50
32
A
13
1400
9
0.20
46
—
A
14
1425
8
0.20
44
42
A
15
1490
7
0.20
40
44
A
16
1530
6
0.20
40
32
1,5
400
4
300
1,0
3
8
200
7
0,5
12
11
2
100
6
16
10
15
14
9
13
0
25
40
438
50
80
75
120
5
100
160
1
150
125
200
240
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
R3G 108-AB15 -02
1.0
G3G 108-BB15 -02
EC centrifugal,
backward
kg
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
1.7
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
183
168,5
71
450+20
439
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
6
85
Technology
Ø118
M4
82
110,5
Accessories
8
79
50
76
159
Ø87-1
83
66
115
97
EC centrifugal fan and blowers
single inlet, Ø 108
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 108
M3G 055-BD
50/60
2800
50
0.38
subject to alterations
1~ 230
A
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
A
2
[Pa]
[in H O]
Curves
300
1,0
4
200
0,5
11
100
2
6
16
10
15
14
9
13
0
25
40
440
50
80
75
120
5
100
160
1
125
200
150
240
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2800
50
0.38
64
—
A
2
2950
44
0.35
62
42
A
3
3120
33
0.25
60
44
A
4
3260
25
0.20
59
32
A
5
2570
38
0.30
61
—
A
6
2660
34
0.25
60
42
A
7
2820
25
0.20
57
44
A
8
2920
19
0.15
55
32
A
9
2150
23
0.20
56
—
A
10
2200
20
0.15
55
42
A
11
2320
16
0.15
52
44
A
12
2390
12
0.10
50
32
A
13
1400
9
0.10
46
—
A
14
1425
8
0.10
44
42
A
15
1490
7
0.10
40
44
A
16
1530
6
0.10
40
32
7
12
P1
[W]
A
3
8
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 108-AB01 -02
1.0
G3G 108-BB01 -02
1.7
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
183
168,5
71
450+20
441
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
6
85
Technology
Ø118
M4
82
110,5
Accessories
8
79
50
76
159
Ø87-1
83
66
115
97
EC centrifugal fan and blowers
single inlet, Ø 120
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 120
M3G 055-BD
50/60
2320
46
0.70
1~ 115
A
subject to alterations
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
A
2
[Pa]
[in H O]
Curves
300
1,0
4
8
3
200
7
0,5
12
11
2
100
16
10
14
9
13
0
25
40
442
50
80
75
120
100
160
5
1
125
200
150
240
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2320
46
0.70
61
—
A
2
2490
40
0.60
59
52
A
3
2640
33
0.50
58
58
A
4
2880
24
0.40
57
51
A
5
2060
34
0.50
59
—
A
6
2190
29
0.45
57
50
A
7
2295
24
0.40
55
54
A
8
2445
18
0.30
54
52
A
9
1830
24
0.40
54
—
A
10
1920
20
0.30
52
50
A
11
2010
17
0.30
51
54
A
12
2115
13
0.20
51
52
A
13
1430
13
0.20
48
—
A
14
1500
12
0.20
45
50
A
15
1580
10
0.20
44
54
A
16
1640
8
0.20
44
52
6
15
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 120-AB13 -02
1.1
G3G 120-BB13 -02
1.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
115
100
Accessories
7
82
Ø132
82
82
86
450 +20
6
85
M4
Technology
190
Ø100-1
98
50
110
443
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
83
68
76
178
EC centrifugal fan and blowers
single inlet, Ø 120
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 120
M3G 055-BD
50/60
2200
41
0.30
1~ 230
A
subject to alterations
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
A
2
[Pa]
[in H O]
Curves
1,0
300
4
8
200
7
0,5
11
100
16
2
10
14
9
13
0
25
40
444
50
80
75
120
100
160
5
1
125
200
150
240
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2200
41
0.30
62
—
A
2
2320
34
0.25
59
51
A
3
2440
28
0.20
57
55
A
4
2600
20
0.15
57
49
A
5
2060
34
0.25
59
—
A
6
2190
29
0.20
57
50
A
7
2295
24
0.20
55
54
A
8
2445
18
0.15
54
52
A
9
1830
24
0.20
54
—
A
10
1920
20
0.15
52
50
A
11
2010
17
0.15
51
54
A
12
2115
13
0.10
51
52
A
13
1430
13
0.10
48
—
A
14
1500
12
0.10
45
50
A
15
1580
10
0.10
44
54
A
16
1640
8
0.10
44
52
6
15
P1
[W]
A
3
12
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 120-AB03 -02
1.1
G3G 120-BB03 -02
1.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
115
100
Accessories
7
82
Ø132
82
82
86
450 +20
6
85
M4
Technology
190
Ø100-1
98
50
110
445
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
83
68
76
178
EC centrifugal fan and blowers
single inlet, Ø 133
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 133
M3G 055-BD
50/60
2000
42
0.60
1~ 115
A
subject to alterations
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Hot-dip galvanised sheet steel
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
A
2
[Pa]
[in H O]
Curves
300
1,0
4
3
200
8
7
0,5
12
11
100
2
10
15
14
9
13
0
25
40
446
50
80
75
120
5
100
160
1
125
200
150
240
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2000
42
0.60
64
—
A
2
2140
37
0.55
62
42
A
3
2310
30
0.45
60
52
A
4
2460
23
0.35
58
51
A
5
1780
30
0.45
60
—
A
6
1870
26
0.40
59
45
A
7
1995
21
0.30
56
53
A
8
2120
17
0.25
56
51
A
9
1495
18
0.30
55
—
A
10
1570
16
0.25
54
45
A
11
1640
13
0.20
51
53
A
12
1730
10
0.20
50
51
A
13
1100
9
0.20
49
—
A
14
1140
8
0.20
47
45
A
15
1200
7
0.20
44
53
A
16
1250
6
0.20
41
51
6
16
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 133-AD11 -02
1.0
G3G 133-DD11 -02
1.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
171
59
Accessories
87
4x90°
180
Ø112-1
71
45°
Ø14
Technology
450 +20
79
447
Inlet nozzle
p. 552
Electr. connection
p. 601
Contacts
92,5
Ø3
6
85
0
EC centrifugal fan and blowers
single inlet, Ø 133
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 133
M3G 055-BD
50/60
1925
38
0.30
1~ 230
A
subject to alterations
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Hot-dip galvanised sheet steel
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
A
2
[Pa]
[in H O]
Curves
1,0
300
4
200
8
0,5
12
11
100
2
10
15
14
9
13
0
25
40
448
50
80
75
120
5
100
160
200
1
125
150
240
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1925
38
0.30
63
—
A
2
2070
34
0.25
62
45
A
3
2210
27
0.20
60
53
A
4
2330
21
0.15
59
51
A
5
1780
30
0.25
60
—
A
6
1870
26
0.20
59
45
A
7
1995
21
0.15
56
53
A
8
2120
17
0.15
56
51
A
9
1495
18
0.15
55
—
A
10
1570
16
0.15
54
45
A
11
1640
13
0.10
51
53
A
12
1730
10
0.10
50
51
A
13
1100
9
0.10
49
—
A
14
1140
8
0.10
47
45
A
15
1200
7
0.10
44
53
A
16
1250
6
0.10
41
51
6
16
P1
[W]
A
3
7
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 133-AD05 -02
1.0
G3G 133-DD05 -02
1.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
171
59
Accessories
87
4x90°
180
Ø112-1
71
45°
Ø14
Technology
450 +20
79
449
Inlet nozzle
p. 552
Electr. connection
p. 601
Contacts
92,5
Ø3
6
85
0
EC centrifugal fan and blowers
single inlet, Ø 140
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 140
M3G 055-CF
50/60
1790
70
1.00
subject to alterations
1~ 115
A
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
2
A
1,25
[Pa]
[in H O]
Curves
300
1,00
3
0,75
0,50
12
0,25
11
6
16
10
15
14
13
100
0
100
450
9
200
1
5
200
300
300
400
500
[CFM]
[m3/h]
LpA
[dB(A)]
tL
[%]
1
1790
70
1.00
63
—
2
1900
63
1.00
61
46
A
3
2040
53
0.80
60
61
A
4
2250
36
0.50
58
55
A
5
1410
33
0.60
58
—
A
6
1500
30
0.55
56
46
A
7
1600
25
0.45
54
56
A
8
1790
18
0.30
53
48
A
9
1060
14
0.35
51
—
A
10
1105
13
0.30
50
46
A
11
1210
11
0.25
47
56
A
12
1355
8
0.20
47
48
A
13
705
4
0.20
40
—
A
14
750
4
0.20
39
46
A
15
800
3
0.20
38
56
A
16
895
3
0.20
37
48
7
100
I
[A]
A
8
2
P1
[W]
A
4
200
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 140-AV19 -02
1.3
G3G 140-AV19 -02
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
max. 227,8
6,6
Accessories
103
107
M4
Technology
247
Ø158
6
85
450 +20
max. 262,6
92
94
Ø118-1
100±1
16
451
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
120
105
130
115
EC centrifugal fan and blowers
single inlet, Ø 140
Max. current
draw (1)
Motor
Hz
rpm
W
A
*3G 140
M3G 055-CF
50/60
1800
66
0.50
subject to alterations
1~ 230
A
Electr. connection
Max. power
input (1)
Type
Perm. amb. temp.
Speed/rpm
Nominal data
Min. back pressure
Frequency
VAC
Curve
Nominal voltage
– Material: Housing: Die-cast aluminium
Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 601
-25 to +60
H1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
A
1,25
[Pa]
[in H O]
Curves
300
1,00
4
200
0,75
3
0,50
2
0,25
11
6
16
10
15
14
13
100
0
100
452
9
200
1
5
200
300
300
400
500
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1800
66
0.50
63
—
A
2
1860
58
0.40
62
46
A
3
1970
49
0.35
60
56
A
4
2170
33
0.25
58
48
A
5
1410
33
0.30
58
—
A
6
1500
30
0.25
56
46
A
7
1600
25
0.25
54
56
A
8
1790
18
0.15
53
48
A
9
1060
14
0.15
51
—
A
10
1105
13
0.15
50
46
A
11
1210
11
0.15
47
56
A
12
1355
8
0.10
47
48
A
13
705
4
0.10
40
—
A
14
750
4
0.10
39
46
A
15
800
3
0.10
38
56
A
16
895
3
0.10
37
48
7
12
P1
[W]
A
8
100
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 140-AV03 -02
1.3
G3G 140-AV03 -02
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Locked-rotor protection
• Output 10 VDC max. 1.1 mA
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
max. 227,8
6,6
Accessories
103
107
M4
Technology
247
Ø158
6
85
450 +20
max. 262,6
92
94
Ø118-1
100±1
16
453
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 601
Contacts
120
105
130
115
EC centrifugal fan and blowers
single inlet, constant air flow, Ø 140
subject to alterations
rpm
W
A
50/60
1340
70
1.00
1~ 115
Electr. connection
Hz
Perm. amb. temp.
A
VAC
Min. back pressure
M3G 055-CF
Max. current
draw (1)
*3G 140
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: PP plastic
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 602
-25 to +60
H2)
0
(1) Nominal data in operating point with maximum load and 115 VAC
[Pa]
Curves
A
1,5
400
1
2
3
200
4
0,5
100
7
10
0
50
100
454
9
8
12
11
100
150
200
200
300
250
400
[CFM]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2390
29
0.40
59
37
A
2
2450
55
0.80
60
50
A
3
2460
67
1.00
60
57
A
4
1920
17
0.30
54
38
A
5
1960
30
0.70
55
54
A
6
2130
55
0.80
60
55
A
7
1300
9
0.20
46
36
A
8
1550
22
0.30
51
48
A
9
1760
40
0.60
58
48
A
10
440
3
0.10
33
—
A
11
880
9
0.15
45
—
A
12
1340
25
0.40
55
—
6
5
P1
[W]
A
1,0
300
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 140-AW21 -12
1.3
G3G 140-AW21 -12
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• Input for set value Lin 0-10 VDC / PWM
• Tach output
• Locked-rotor protection
(1.7 V 50 m3/h, 10 V 300 m3/h)
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
– Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
max. 227,8
6,6
Accessories
103
107
M4
Technology
247
Ø158
6
85
450 +20
max. 262,6
92
94
Ø118-1
100±1
16
455
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 602
Contacts
120
105
130
115
EC centrifugal fan and blowers
single inlet, constant air flow, Ø 140
subject to alterations
rpm
W
A
50/60
1380
70
0.60
1~ 230
Electr. connection
Hz
Perm. amb. temp.
A
VAC
Min. back pressure
M3G 055-CF
Max. current
draw (1)
*3G 140
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: PP plastic
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 602
-25 to +60
H2)
0
(1) Nominal data in operating point with maximum load and 230 VAC
[Pa]
Curves
A
1,5
400
300
1
2
200
0,5
100
10
0
50
100
456
9
8
7
12
11
100
150
200
200
300
250
400
[CFM]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2380
33
0.25
59
37
A
2
2495
51
0.45
60
50
A
3
2400
67
0.55
60
57
A
4
2030
22
0.20
54
38
A
5
2000
34
0.30
55
54
A
6
2110
61
0.50
60
55
A
7
1325
12
0.10
46
36
A
8
1460
21
0.20
51
48
A
9
1755
43
0.35
58
48
A
10
480
3
0.05
33
—
A
11
890
11
0.10
45
—
A
12
1380
31
0.25
55
—
6
5
4
P1
[W]
A
1,0
3
n
[rpm]
General
information
Centrifugal fan
kg
Centrifugal blower
with flange
kg
R3G 140-AW05 -12
1.3
G3G 140-AW05 -12
2.6
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• Input for set value Lin 0-10 VDC / PWM
• Tach output
• Locked-rotor protection
(1.7 V 50 m3/h, 10 V 300 m3/h)
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: GOST; VDE, UL, CSA, CCC are applied for
– Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586)
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 6 mm
Brass lead tips
max. 227,8
6,6
Accessories
103
107
M4
Technology
247
Ø158
6
85
450 +20
max. 262,6
92
94
Ø118-1
100±1
16
457
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 602
Contacts
120
105
130
115
EC centrifugal fan and blowers
single inlet, Ø 146
subject to alterations
rpm
W
A
50/60
2430
170
2.20
1~ 100-130
A
Electr. connection
Hz
Perm. amb. temp.
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
*3G 146
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
A
2
[Pa]
[in H O]
Curves
600
2,0
500
4
3
8
400
1,5
7
300
12
1,0
2
0,5
6
16
15
100
10
14
13
0
100
100
458
9
200
200
300
400
5
300
500
1
[CFM]
600
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2430
168
2.10
71
—
A
2
2720
167
2.10
70
40
A
3
3040
159
2.00
68
55
A
4
3230
119
1.50
67
50
A
5
2120
110
1.40
67
—
A
6
2390
109
1.40
66
40
A
7
2700
109
1.40
65
56
A
8
2800
77
1.00
63
49
A
9
1770
66
0.90
63
—
A
10
1980
66
0.90
62
39
A
11
2230
65
0.90
60
53
A
12
2330
48
0.70
59
44
A
13
1250
26
0.40
54
—
A
14
1390
26
0.40
52
32
A
15
1520
24
0.40
51
43
A
16
1560
19
0.30
50
32
11
200
n
[rpm]
General
information
Centrifugal blower
with flange
kg
R3G 146-AB72 -01
2.0
G3G 146-AB72 -01
3.5
AC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
M4
117±1,5
114±1,5
84,5±1
EC centrifugal,
forward
M4
M4
45˚
0
+2
EC-SYSTEMS
max. 62,5
Ø5
Ø9 8
Ø1 0
25
min. Ø119,5
max. Ø146,5
4x90˚
Ø92
Ø133±0,3
max. Ø115,3
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
Centrifugal fan
45
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
0
8
85
94
max. 262,6
58
Ø125,5 -1
Ø1
108
M4
45 85
0 +2
100±1
0
Technology
Accessories
103
92
120
105
max. 227,8
Ø6,3
130
115
Core-end sleeves
8
459
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 603
Contacts
132,5±1,5
EC centrifugal fan and blowers
single inlet, Ø 146
subject to alterations
rpm
W
A
50/60
2520
175
1.30
1~ 200-277
A
Electr. connection
Hz
Perm. amb. temp.
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
*3G 146
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
A
2
[Pa]
[in H O]
Curves
600
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2520
175
1.30
71
—
A
2
2840
172
1.20
70
43
A
3
3030
144
1.10
68
60
A
4
3210
105
0.80
67
51
A
5
2430
172
1.30
71
—
A
6
2545
138
1.10
68
42
A
7
2655
105
0.80
65
60
A
8
2770
78
0.60
63
50
A
9
2080
108
0.80
67
—
A
10
2160
84
0.70
64
41
A
11
2240
70
0.60
66
52
A
12
2310
50
0.40
59
51
A
13
1540
48
0.40
59
—
A
14
1580
39
0.30
56
34
A
15
1610
29
0.25
52
41
A
16
1640
22
0.20
51
40
500
2,0
4
3
8
1,5
400
7
300
12
1,0
11
2
200
6
16
0,5
15
10
100
14
13
0
100
100
460
9
300
200
200
300
400
500
5 1
[CFM]
600
[m3/h]
General
information
Centrifugal blower
with flange
kg
R3G 146-AB54 -01
2.0
G3G 146-AB54 -01
3.5
AC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
M4
117±1,5
114±1,5
84,5±1
EC centrifugal,
forward
M4
M4
45˚
0
+2
EC-SYSTEMS
max. 62,5
Ø5
Ø9 8
Ø1 0
25
min. Ø119,5
max. Ø146,5
4x90˚
Ø92
Ø133±0,3
max. Ø115,3
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
Centrifugal fan
45
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
0
8
85
94
max. 262,6
58
Ø125,5 -1
Ø1
108
M4
45 85
0 +2
100±1
0
Technology
Accessories
103
92
120
105
max. 227,8
Ø6,3
130
115
Core-end sleeves
8
461
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 603
Contacts
132,5±1,5
EC centrifugal fan and blowers
single inlet, Ø 160
W
A
50/60
2100
170
2.20
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 100-130
A
subject to alterations
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
*3G 160
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
A
2
[Pa]
[in H O]
Curves
600
2,0
4
500
400
1,5
300
1,0
7
12
200
0,5
11
2
100
16
6
15
10
14
13
0
100
100
462
9
200
200
300
400
5
300
500
1
[CFM]
600
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2100
166
2.10
69
—
A
2
2230
167
2.10
68
41
A
3
2550
164
2.10
69
58
A
4
2640
104
1.40
67
49
A
5
1810
106
1.40
64
—
A
6
1930
105
1.40
64
38
A
7
2160
102
1.30
65
55
A
8
2230
62
0.90
62
43
A
9
1510
64
0.90
60
—
A
10
1600
64
0.90
60
36
A
11
1780
61
0.90
60
49
A
12
1830
41
0.60
58
39
A
13
1020
25
0.40
51
—
A
14
1080
24
0.40
50
29
A
15
1150
22
0.30
50
37
A
16
1170
16
0.30
47
25
3
8
n
[rpm]
General
information
Centrifugal blower
with flange
kg
R3G 160-AC70 -01
2.0
G3G 160-AC70 -01
3.5
EC centrifugal,
forward
M4
M4
45˚
EC-SYSTEMS
max. 61,7
Ø5
Ø9 8
Ø1 0
25
min. Ø136
max. Ø160,5
4x90˚
Ø92
Ø133±0,3
max. Ø115,3
AC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
M4
114±1,5
111±1,5
81,5±1
45
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
Centrifugal fan
0
+2
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
0
8
85
94
max. 262,6
75
Ø130-1
Ø1
108
M4
45 85
0 +2
100±1
0
Technology
Accessories
103
92
120
105
max. 227,8
Ø6,3
130
115
Core-end sleeves
8
463
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 603
Contacts
132,5±1,5
EC centrifugal fan and blowers
single inlet, Ø 160
W
A
50/60
2150
175
1.30
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 200-277
A
subject to alterations
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
*3G 160
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
A
2
[Pa]
[in H O]
Curves
500
2,0
600
4
400
1,5
8
3
300
1,0
7
0,5
11
2
16
100
6
15
10
14
0
100
464
13
200
100
200
300
9
300
400
500
5 1
[CFM]
600
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
2150
170
1.25
70
—
A
2
2320
172
1.30
70
39
A
3
2450
139
1.10
68
41
A
4
2540
91
0.70
67
46
A
5
2070
153
1.10
69
—
A
6
2090
138
1.00
67
40
A
7
2150
101
0.80
65
56
A
8
2205
68
0.60
63
45
A
9
1700
91
0.70
63
—
A
10
1730
80
0.60
62
37
A
11
1760
60
0.50
59
49
A
12
1795
41
0.30
58
37
A
13
1190
37
0.30
54
—
A
14
1200
33
0.30
53
29
A
15
1220
27
0.25
51
35
A
16
1240
20
0.20
48
27
12
200
n
[rpm]
General
information
Centrifugal blower
with flange
kg
R3G 160-AC50 -01
2.0
G3G 160-AC50 -01
3.5
EC centrifugal,
forward
M4
M4
45˚
EC-SYSTEMS
max. 61,7
Ø5
Ø9 8
Ø1 0
25
min. Ø136
max. Ø160,5
4x90˚
Ø92
Ø133±0,3
max. Ø115,3
AC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
M4
114±1,5
111±1,5
81,5±1
45
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
Centrifugal fan
0
+2
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
0
8
85
94
max. 262,6
75
Ø130-1
Ø1
108
M4
45 85
0 +2
100±1
0
Technology
Accessories
103
92
120
105
max. 227,8
Ø6,3
130
115
Core-end sleeves
8
465
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 603
Contacts
132,5±1,5
EC centrifugal fan and blowers
single inlet, constant air flow, Ø 160
subject to alterations
rpm
W
A
50/60
1340
175
1.30
1~ 230
A
Electr. connection
Hz
Perm. amb. temp.
VAC
Min. back pressure
M3G 074-BF
Max. current
draw (1)
*3G 160
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 604
-25 to +60
J2)
0
(1) Nominal data in operating point with maximum load and 230 VAC
[Pa]
Curves
A
3,0
800
600
2
3
400
4
1,0
200
8
7
11
10
0
50
100
466
100
150
200
9
12
200
300
250
400
[CFM]
I
[A]
LpA
[dB(A)]
tL
[%]
1
2910
110
0.90
68
44
A
2
2930
142
1.10
69
52
A
3
2780
175
1.30
71
63
A
4
2380
68
0.60
63
47
A
5
2360
88
0.70
65
58
A
6
2450
132
0.95
67
62
A
7
1690
35
0.30
57
49
A
8
1760
51
0.40
60
56
A
9
2020
94
0.70
63
50
A
10
610
9
0.10
40
—
A
11
950
22
0.25
51
—
A
12
1340
51
0.40
58
—
6
5
P1
[W]
A
2,0
1
n
[rpm]
kg
R3G 160-AD52 -01
2.0
G3G 160-AD52 -01
3.5
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
M4
EC centrifugal,
forward
Ø5
Ø9 8
Ø1 0
25
max. 61,7
45˚
EC-SYSTEMS
45
M4
M4
min. Ø136
max. Ø160,5
4x90˚
Ø92
Ø133±0,3
max. Ø115,3
114±1,5
111±1,5
81,5±1
AC centrifugal,
backward
General
information
Centrifugal blower
with flange
EC centrifugal, backward for clean rooms
kg
EC centrifugal,
backward
Mass of
centrifugal blower
Mass of
centrifugal fan
Centrifugal fan
0
+2
• Over-temperature protected electronics / motor
AC centrifugal,
forward
– Technical features:
• PFC (passive)
• Input for set value Lin 0-10 VDC / PWM
• Output 10 VDC max. 1.1 mA
• Tach output
(1.7 V 50 m3/h, 10 V 300 m3/h)
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
– Air intake: Constant air flow curves can only be attained with unobstructed air intake (s. p. 586)
0
8
85
94
max. 262,6
75
Ø130-1
Ø1
108
M4
45 85
0 +2
100±1
0
Technology
Accessories
103
92
120
105
max. 227,8
Ø6,3
130
115
Core-end sleeves
8
467
Inlet nozzle
p. 552
Guard grille
p. 554
Air filter
p. 563
Electr. connection
p. 604
Contacts
132,5±1,5
EC centrifugal fan and blowers
single inlet, Ø 180
W
A
50/60
1320
175
2.20
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 100-130
A
subject to alterations
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
*3G 180
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 115 VAC
2
300
1,00
4
200
0,75
3
0,50
8
0,25
12
2
11
6
16
15
10
14
9
13
0
100
200
468
300
200
400
5
400
600
1
500
800
600
1000
[CFM]
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1320
171
2.10
67
—
A
2
1370
151
1.90
65
57
A
3
1460
115
1.50
61
69
A
4
1570
69
0.90
59
59
A
5
990
69
0.90
59
—
A
6
1030
65
0.90
57
54
A
7
1080
48
0.70
54
64
A
8
1130
29
0.40
51
57
A
9
770
35
0.50
52
—
A
10
790
30
0.40
50
49
A
11
810
23
0.30
46
55
A
12
840
15
0.20
42
40
A
13
560
16
0.20
44
—
A
14
560
13
0.20
40
38
A
15
580
11
0.20
36
41
A
16
590
8
0.10
33
24
7
100
n
[rpm]
A
A
1,25
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 180-AU73 -01
2.0
G3G 180-EU73 -01
4.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
179,5
129
285
136
Ø149-1
2
Ø19
0
8
469
Inlet nozzle
p. 552
Guard grille
p. 554
Electr. connection
p. 603
Contacts
45 85
0 +2
Technology
332
6
Ø3,2
5°
°
0
x6
Accessories
123
134
Core-end sleeves
EC centrifugal fan and blowers
single inlet, Ø 180
subject to alterations
Min. back pressure
Perm. amb. temp.
Electr. connection
M3G 074-CF
Max. current
draw (1)
*3G 180
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
p. 603
50/60
1320
162
1.20
150
-25 to +60
J1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
200
4
0,75
250
1,0
300
3
150
8
100
7
0,25
6
12
11
50
10
16
15
14
13
0
200
470
5
9
200
400
400
600
800
600
[CFM]
1000
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1420
118
1.90
62
59
A
3
1445
106
1.50
61
69
A
4
1530
65
1.00
59
56
A
5
975
65
1.00
58
—
A
6
995
56
0.90
56
54
A
7
1025
42
0.70
53
60
A
8
1065
26
0.45
49
45
A
9
745
31
0.50
52
—
A
10
755
28
0.45
49
47
A
11
775
21
0.35
45
49
A
12
805
15
0.25
42
34
A
13
515
33
0.25
41
—
A
14
520
12
0.20
39
33
A
15
535
10
0.20
35
34
A
16
560
8
0.15
32
20
0,5
2
P1
[W]
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 180-AU60 -01
2.0
G3G 180-EU60 -01
4.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw)
Depth of screw max. 6 mm (core removing hole prepared for self-tapping screw)
Depth of screw 8-10 mm
179,5
129
285
136
Ø149-1
2
Ø19
0
8
471
Inlet nozzle
p. 552
Guard grille
p. 554
Electr. connection
p. 603
Contacts
45 85
0 +2
Technology
332
6
Ø3,2
5°
°
0
x6
Accessories
123
134
Core-end sleeves
EC centrifugal fan and blowers
single inlet, Ø 180
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1970
335
3.90
200
-25 to +60
K1)
1~ 100-130
A
subject to alterations
Min. back pressure
M3G 084-DF
Max. current
draw (1)
*3G 180
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 115 VAC
n
[rpm]
2
[Pa]
2,5 [in H O]
Curves
4
2,0
500
3
1,5
400
300
8
1,0
7
12
2
11
200
0,5
6
10
100
0
472
400
200
200
400
600
600
800
1000
800
1200
1400
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1970
335
3.90
76
52
A
3
2100
265
3.15
72
62
A
4
2205
195
2.35
70
56
A
5
—
—
—
—
—
A
6
1700
213
2.45
71
52
A
7
1700
140
1.65
65
62
A
8
1700
90
1.10
63
56
A
600
P1
[W]
A
9
—
—
—
—
—
A
10
1500
147
1.70
68
52
A
11
1500
96
1.15
62
62
A
12
1500
61
0.75
59
46
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 180-AA01 -81
3.9
G3G 180-AA01 -81
6.0
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
285
195
5°
°
0
x6
Accessories
123
134
129
Ø3,2
Core-end sleeves
Technology
Ø149 -1
332
6
2
136
0
+2
0
60
Ø19
85
Guard grille
p. 554
Electr. connection
p. 605
Contacts
8
473
Inlet nozzle
p. 552
EC centrifugal fan and blowers
single inlet, Ø 180
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
2450
510
3.15
300
-25 to +60
K1)
1~ 200-277
A
subject to alterations
Min. back pressure
M3G 084-FA
Max. current
draw (1)
*3G 180
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 230 VAC
n
[rpm]
2
A
3
2,0
600
2,5
4
8
1,5
400
7
1,0
2
200
12
6
0,5
11
10
9
250
0
200
474
400
5
750
500
600
800
1000
1200
[CFM]
1400
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
—
—
—
—
—
A
2
2450
510
3.15
79
47
A
3
2570
361
2.25
75
58
A
4
2690
223
1.45
73
45
A
5
2000
395
2.50
77
—
A
6
2000
295
1.90
73
47
A
7
2000
185
1.20
68
58
A
8
2000
100
0.60
64
45
A
9
1400
135
0.90
67
—
A
10
1400
100
0.60
64
47
A
11
1400
65
0.40
59
58
A
12
1400
35
0.20
55
45
3,0
800
P1
[W]
A
3,5
[Pa]
[in H O]
Curves
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 180-AD43 -71
4.7
G3G 180-AD43 -71
6.8
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
285
195
5°
°
0
x6
Accessories
123
134
129
Ø3,2
Core-end sleeves
Technology
Ø149 -1
332
6
2
136
0
+2
0
60
Ø19
85
Guard grille
p. 554
Electr. connection
p. 605
Contacts
8
475
Inlet nozzle
p. 552
EC centrifugal fan and blowers
single inlet, Ø 200
subject to alterations
Perm. amb. temp.
Electr. connection
A
Min. back pressure
M3G 084-FA
Max. current
draw (1)
*3G 200
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1720
350
4.20
150
-25 to +60
K1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
n
[rpm]
2
2,4
[Pa]
500
A
2,0
600
[in H O]
Curves
400
1,6
4
1,2
200
0,8
3
300
100
0,4
2
250
0
200
476
400
500
600
800
750
1000
1200
[CFM]
1400
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1720
350
4.10
73
49
A
3
1780
277
3.40
71
58
A
4
1945
152
2.10
69
50
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 200-AL36 -81
5.2
G3G 200-AL36 -81
7.4
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
318
5°
°
60
371
3
Ø21
+2
0
60
0
152
85
8
477
Inlet nozzle
p. 552
Electr. connection
p. 605
Contacts
Ø175 -1
6x
Accessories
146
136
Technology
208
142,5
Ø3,2
Core-end sleeves
EC centrifugal fan and blowers
single inlet, Ø 200
subject to alterations
Perm. amb. temp.
Electr. connection
A
Min. back pressure
M3G 084-FA
Max. current
draw (1)
*3G 200
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1890
510
3.10
150
-25 to +60
K1)
1~ 200-277
(1) Nominal data in operating point with maximum load and 230 VAC
n
[rpm]
300
2
2,4
8
3
7
0,8
12
200
11
6
2
16
0,4
100
15
10
14
9
13
250
0
200
478
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1890
490
3.00
76
46
A
3
1960
403
2.40
74
57
A
4
2050
322
2.00
73
58
A
5
1800
510
3.10
77
—
A
6
1800
420
2.50
75
46
A
7
1800
320
1.90
71
57
A
8
1800
220
1.30
69
58
A
9
1400
240
1.50
71
—
A
10
1400
200
1.20
68
46
A
11
1400
145
0.90
65
57
A
12
1400
103
0.70
63
58
A
13
1000
87
0.60
63
—
A
14
1000
72
0.50
60
46
A
15
1000
55
0.40
57
57
A
16
1000
38
0.30
53
58
4
2,0
[Pa]
400
P1
[W]
1,6
500
A
1,2
600
[in H O]
Curves
400
500
600
800
750
1000
1200
5
[CFM]
1400
[m3/h]
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 200-AL29 -71
5.2
G3G 200-AL29 -71
7.4
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
318
5°
°
60
371
3
Ø21
+2
0
60
0
152
85
8
479
Inlet nozzle
p. 552
Electr. connection
p. 605
Contacts
Ø175 -1
6x
Accessories
146
136
Technology
208
142,5
Ø3,2
Core-end sleeves
EC centrifugal fan and blowers
single inlet, Ø 225
subject to alterations
Perm. amb. temp.
Electr. connection
A
Min. back pressure
M3G 084-FA
Max. current
draw (1)
*3G 225
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1500
350
4.30
150
-25 to +60
K1)
1~ 100-130
(1) Nominal data in operating point with maximum load and 115 VAC
n
[rpm]
2
2,4
[Pa]
500
A
2,0
600
[in H O]
Curves
1,6
4
400
1,2
200
0,8
3
300
0,4
2
100
250
0
200
480
400
500
600
800
750
1000
1200
[CFM]
1400
[m3/h]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1500
350
4.30
72
48
A
3
1620
300
3.60
69
60
A
4
1775
205
2.70
68
56
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 225-AL36 -81
5.3
G3G 225-AL36 -81
7.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
318
146
5°
°
0
x6
Accessories
148
136
208
142,5
Ø3,2
Core-end sleeves
152
0
+2
Technology
371
2
Ø24
0
60
85
8
481
Inlet nozzle
p. 552
Electr. connection
p. 605
Contacts
Ø194 -1
6
EC centrifugal fan and blowers
single inlet, Ø 225
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1815
545
3.50
300
-25 to +60
K1)
1~ 200-277
A
subject to alterations
Min. back pressure
M3G 084-FA
Max. current
draw (1)
*3G 225
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 230 VAC
n
[rpm]
2
2,4
[Pa]
400
4
2,0
500
A
3
1,6
600
[in H O]
Curves
1,2
2
12
0,8
11
10
16
0,4
0
14
250
400
482
tL
[%]
1
—
—
—
—
—
A
2
1815
545
3.50
75
53
A
3
1900
456
2.90
74
60
A
4
1995
363
2.35
73
59
A
5
1610
592
3.85
76
—
A
6
1610
381
2.45
71
53
A
7
1610
278
1.80
69
60
A
8
1610
191
1.25
66
59
A
9
1300
312
2.05
72
—
A
10
1300
200
1.30
66
53
A
11
1300
146
0.95
63
60
A
12
1300
101
0.65
61
59
A
13
1000
142
0.95
65
—
A
14
1000
91
0.60
59
53
A
15
1000
67
0.45
56
60
A
16
1000
46
0.30
54
59
15
100
LpA
[dB(A)]
A
6
200
I
[A]
8
7
300
P1
[W]
500
800
13
750
1200
9
1000
1600
5
[CFM]
[m3/h]
General
information
Centrifugal fan
kg
Centrifugal blower
without flange
kg
R3G 225-AD29 -71
5.3
G3G 225-AD29 -71
7.5
EC centrifugal,
backward
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, CCC, GOST are applied for
EC-SYSTEMS
EC centrifugal,
forward
Depth of screw 8-10 mm
318
146
5°
°
0
x6
Accessories
148
136
208
142,5
Ø3,2
Core-end sleeves
152
0
+2
Technology
371
2
Ø24
0
60
85
8
483
Inlet nozzle
p. 552
Electr. connection
p. 605
Contacts
Ø194 -1
6
EC centrifugal fan
single inlet, Ø 250
subject to alterations
Min. back pressure
Perm. amb. temp.
Electr. connection
M3G 084-FA
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on top; rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
W
A
Pa
°C
p. 605
50/60
1230
450
2.90
180
-25 to +45
K1)
1~ 200-277
A
(1) Nominal data in operating point with maximum load and 230 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
400
1,4
350
4
1,2
300
200
0,8
250
1,0
7
2
12
100
0,6
10
15
0,2
16
50
6
0,4
150
11
14
0
250
400
484
500
800
750
1200
1000
1600
1250
2000
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1230
450
2.90
72
50
A
3
1370
338
2.20
70
60
A
4
1460
266
1.70
68
56
A
5
—
—
—
—
—
A
6
1160
357
2.30
71
50
A
7
1270
269
1.70
67
60
A
8
1320
195
1.30
66
56
A
9
—
—
—
—
—
A
10
900
166
1.10
64
50
A
11
960
118
0.80
60
60
A
12
990
87
0.60
58
56
A
13
—
—
—
—
—
A
14
600
54
0.40
53
50
A
15
630
37
0.30
48
60
A
16
640
31
0.20
46
56
3
8
P1
[W]
General
information
Centrifugal fan
kg
Inlet nozzle
Flange
R3G 250-AQ28 -71
5.6
25010-2-4013
10011-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Alarm relay
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: UL, CSA, GOST; CCC is applied for
Depth of screw 8-10 mm
Core-end sleeves
Scroll housing used:
138
18
147
30˚
30˚ 30˚
158
485
Inlet nozzle
p. 552
Electr. connection
p. 605
Contacts
170
184
˚
30
30
˚
30˚
213
Technology
30
˚
65
˚
25˚
230
30˚
30˚
247
203
267
287
150
198
View Z
Accessories
Housing width
EC centrifugal fan
single inlet, Ø 250
subject to alterations
rpm
kW
A
50/60
1320
0.76
3.30
1~ 200-277
Electr. connection
Hz
Perm. amb. temp.
A
VAC
Min. back pressure
M3G 112-EA
Max. current
draw (1)
R3G 250
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 607
-25 to +60
L1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
4
1,4
[Pa]
300
A
1,2
350
[in H O]
Curves
250
1,0
200
0,8
8
3
7
0,6
2
150
12
6
100
0,4
11
10
50
0,2
16
15
14
9
13
0
250
400
486
500
800
750
1200
1000
1600
5
1250
2000
1
[CFM]
2400
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1320
0.76
3.30
81
—
A
2
1380
0.61
2.70
78
46
A
3
1410
0.51
2.30
76
50
A
4
1450
0.39
1.70
73
53
A
5
1190
0.55
2.40
78
—
A
6
1220
0.43
1.90
75
46
A
7
1250
0.36
1.60
73
50
A
8
1280
0.28
1.20
69
53
A
9
910
0.25
1.10
71
—
A
10
930
0.20
0.90
67
46
A
11
940
0.16
0.70
65
50
A
12
950
0.13
0.60
61
53
A
13
610
0.09
0.40
59
—
A
14
610
0.07
0.40
55
46
A
15
620
0.06
0.30
53
50
A
16
630
0.05
0.30
49
53
General
information
AC centrifugal,
backward
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
Centrifugal fan
kg
Inlet nozzle
Flange
R3G 250-AS51 -11
7.6
25010-2-4013
10025-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 610800-5-1)
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST, CCC are applied for
Housing width
Depth of screw 12-16 mm
Scroll housing used:
138
18
147
30˚
30˚ 30˚
158
487
Inlet nozzle
p. 552
Electr. connection
p. 607
Contacts
170
184
˚
30
30
˚
30˚
213
Technology
30
˚
65
˚
25˚
230
30˚
30˚
247
203
267
287
150
198
View Z
Accessories
Cable gland
EC centrifugal fan
single inlet, Ø 280
kW
A
50/60
1130
0.75
3.30
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 200-277
A
subject to alterations
VAC
Min. back pressure
M3G 112-GA
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 607
-25 to +50
L1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
[Pa]
A
2,0
500
[in H O]
Curves
400
1,6
4
300
1,2
8
3
0,8
12
2
6
100
0,4
11
10
16
15
14
13
0
400
488
800
5
1
1500 [CFM]
9
1000
500
1200
1600
2000
2400
[m3/h]
P1
[kW]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1130
0.75
3.30
78
—
A
2
1170
0.60
2.70
75
53
A
3
1210
0.53
2.30
73
54
A
4
1250
0.32
1.40
69
51
A
5
1020
0.56
2.50
76
—
A
6
1050
0.44
2.00
72
53
A
7
1070
0.37
1.60
70
54
A
8
1110
0.23
1.00
65
51
A
9
780
0.25
1.10
69
—
A
10
790
0.20
0.90
65
53
A
11
800
0.17
0.80
63
54
A
12
820
0.11
0.50
58
51
A
13
520
0.09
0.40
58
—
A
14
530
0.08
0.40
54
53
A
15
530
0.07
0.30
51
54
A
16
550
0.05
0.30
46
51
7
200
n
[rpm]
General
information
AC centrifugal,
backward
Line undervoltage detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
forward
•
•
•
•
•
Centrifugal fan
kg
Inlet nozzle
Flange
R3G 280-AN32 -11
9.4
28010-2-4013
10026-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
– Technical features:
• Slave output 0-10 V max. 3 mA
• PFC (active)
• Output 20 VDC (±20 %) max. 50 mA
• Integrated PID controller
• Output 10 VDC (+10 %) max. 10 mA
• Control input 0-10 VDC / PWM
• RS485 ebmBUS
• Input for sensor 0-10 V or 4-20 mA
• Alarm relay
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 610800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST, CCC are applied for
Housing width
Depth of screw 12-16 mm
Scroll housing used:
162
13
152
30˚
30
30˚ 30˚
148
489
Inlet nozzle
p. 552
Electr. connection
p. 607
Contacts
161
172
˚
30
˚
30˚
200
Technology
30
˚
65
˚
25˚
218
30˚
30˚
236
205
254
266
180
183
View Z
Accessories
Cable gland
EC centrifugal fan
single inlet, Ø 280
kW
A
50/60
1300
1.10
2.00
Electr. connection
rpm
Perm. amb. temp.
Hz
3~ 380-480
A
subject to alterations
VAC
Min. back pressure
M3G 112-GA
Max. current
draw (1)
R3G 280
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 607
-25 to +50
L2)
0
(1) Nominal data in operating point with maximum load and 400 VAC
A
2
[Pa]
[in H O]
Curves
700
2,8
800
400
3
1,2
12
200
0,8
2
16
10
0,4
100
6
11
15
14
400
490
13
1000
500
0
800
1200
1600
5
9
1
1500
2000
2400
[CFM]
2800
3200
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1300
1.10
2.00
82
—
A
2
1370
0.94
1.80
79
55
A
3
1420
0.81
1.50
77
59
A
4
1540
0.53
1.00
73
57
A
5
1200
0.87
1.60
79
—
A
6
1260
0.73
1.40
76
55
A
7
1310
0.62
1.20
75
59
A
8
1400
0.40
0.80
71
57
A
9
970
0.46
0.90
74
—
A
10
990
0.36
0.80
70
55
A
11
1010
0.30
0.60
68
59
A
12
1050
0.19
0.50
63
57
A
13
660
0.16
0.40
64
—
A
14
680
0.13
0.30
60
55
A
15
680
0.11
0.30
58
59
A
16
710
0.08
0.20
53
57
7
300
P1
[kW]
A
8
2,0
500
1,6
600
2,4
4
n
[rpm]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
Centrifugal fan
kg
Inlet nozzle
Flange
R3G 280-AN32 -01
9.4
28010-2-4013
10026-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 610800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST, CCC are applied for
Housing width
Depth of screw 12-16 mm
Scroll housing used:
162
13
152
30˚
30
30˚ 30˚
148
491
Inlet nozzle
p. 552
Electr. connection
p. 607
Contacts
161
172
˚
30
˚
30˚
200
Technology
30
˚
65
˚
25˚
218
30˚
30˚
236
205
254
266
180
183
View Z
Accessories
Cable gland
EC centrifugal fan
single inlet, Ø 310
subject to alterations
Perm. amb. temp.
Electr. connection
A
Min. back pressure
M3G 150-FF
Max. current
draw (1)
R3G 310
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
Pa
°C
p. 608
50/60
1500
2.97
4.60
200
-25 to +45
M)
3~ 380-480
(1) Nominal data in operating point with maximum load and 400 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
4
800
2,4
300
200
3
7
11
6
100
0,4
15
10
14
0
500
1000
492
1000
2000
1500
2000
3000
2500
4000
3000
5000
[CFM]
[m3/h]
tL
[%]
1
—
—
—
—
—
2
1500
2.97
4.60
88
47
A
3
1600
2.34
3.70
85
57
A
4
1730
1.37
2.10
82
56
A
5
—
—
—
—
—
A
6
1350
2.19
3.30
85
47
A
7
1440
1.71
2.60
82
57
A
8
1540
0.96
1.60
79
56
A
9
—
—
—
—
—
A
10
1080
1.12
1.80
80
47
A
11
1120
0.82
1.40
76
57
A
12
1170
0.47
1.00
72
56
A
13
—
—
—
—
—
A
14
730
0.37
0.90
69
47
A
15
750
0.27
0.70
65
57
A
16
780
0.16
0.50
60
56
2
16
LpA
[dB(A)]
A
12
0,8
400
1,6
500
1,2
600
2,0
2,8
8
700
I
[A]
A
3,2
900
P1
[kW]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
R3G 310-AU07 -03
19.4
Inlet nozzle
Flange
31010-2-4013
10050-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Depth of screw 20-25 mm
Scroll housing used:
176
18
186
30˚
30
30˚ 30˚
200
493
Inlet nozzle
p. 552
Electr. connection
p. 608
Contacts
214
229
˚
30
˚
30˚
264
Technology
65
˚
25˚
283
30˚
30
˚
303
249
325
349
184
30˚
View Z
Accessories
Housing width
246
Cable gland
EC centrifugal fan
single inlet, Ø 355
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
Pa
°C
p. 608
50/60
1180
2.60
4.00
300
-25 to +35
M)
3~ 380-480
A
subject to alterations
Min. back pressure
M3G 150-FF
Max. current
draw (1)
R3G 355
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 400 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
700
3
400
2,4
7
2,0
500
8
1,6
600
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1180
2.60
4.00
84
54
A
3
1280
1.95
3.00
80
64
A
4
1350
1.52
2.30
79
64
A
5
—
—
—
—
—
A
6
1050
1.91
2.90
82
54
A
7
1130
1.36
2.00
77
64
A
8
1190
1.02
1.60
75
64
A
9
—
—
—
—
—
A
10
840
0.97
1.70
76
54
A
11
890
0.66
1.30
71
64
A
12
920
0.49
1.00
68
64
A
13
—
—
—
—
—
A
14
580
0.31
0.70
65
54
A
15
600
0.22
0.60
59
64
A
16
610
0.17
0.50
56
64
4
2,8
800
3,2
900
P1
[kW]
300
1,2
12
11
2
200
0,8
6
16
0,4
100
10
15
14
0
500
1000
494
1000
2000
1500
2000
3000
2500
4000
3000
5000
3500
[CFM]
6000
[m3/h]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
R3G 355-AR08 -03
19.9
Inlet nozzle
Flange
35510-2-4013
10051-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Depth of screw 20-25 mm
Scroll housing used:
196
18
207
30˚
30
30˚ 30˚
222
495
Inlet nozzle
p. 552
Electr. connection
p. 608
Contacts
238
256
˚
30
˚
30˚
294
Technology
65
˚
25˚
315
30˚
30
˚
338
280
362
389
203
30˚
View Z
Accessories
Housing width
274
Cable gland
EC centrifugal fan
single inlet, Ø 400
subject to alterations
Min. back pressure
Perm. amb. temp.
Electr. connection
M3G 150-IF
Max. current
draw (1)
R3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
Pa
°C
p. 608
50/60
930
2.13
3.30
200
-25 to +45
M)
3~ 380-480
A
(1) Nominal data in operating point with maximum load and 400 VAC
n
[rpm]
2
2,4
[Pa]
400
4
2,0
500
A
1,6
600
[in H O]
Curves
1,2
7
0,8
11
2
16
6
15
10
0,4
100
14
0
500
1000
496
LpA
[dB(A)]
tL
[%]
1
—
—
—
—
—
A
2
930
2.13
3.30
83
54
A
3
980
1.68
2.60
80
63
A
4
1040
0.93
1.60
74
61
A
5
—
—
—
—
—
A
6
830
1.49
2.40
80
54
A
7
830
1.01
1.60
75
63
A
8
830
0.46
0.80
67
61
A
9
—
—
—
—
—
A
10
700
0.91
1.40
76
54
A
11
700
0.62
1.00
71
63
A
12
700
0.28
0.50
63
61
A
13
—
—
—
—
—
A
14
550
0.44
0.70
69
54
A
15
550
0.30
0.50
65
63
A
16
550
0.14
0.20
56
61
3
12
200
I
[A]
A
8
300
P1
[kW]
1000
2000
1500
2000
3000
2500
4000
3000
5000
3500
6000
4000
7000
[CFM]
[m3/h]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
R3G 400-AR04 -03
25.5
Inlet nozzle
Flange
40010-2-4013
10052-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Depth of screw 20-25 mm
Scroll housing used:
220
20
233
30˚
30
30˚ 30˚
250
497
Inlet nozzle
p. 552
Electr. connection
p. 608
Contacts
268
288
˚
30
˚
30˚
331
Technology
65
˚
25˚
355
30˚
30
˚
380
316
408
437
228
30˚
View Z
Accessories
Housing width
308
Cable gland
EC centrifugal fan
single inlet, Ø 400
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
Pa
°C
p. 608
50/60
1120
3.080
4.60
300
-25 to +55
M)
3~ 380-480
A
subject to alterations
Min. back pressure
M3G 150-NA
Max. current
draw (1)
R3G 400
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 400 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
800
600
2,8
2,4
700
4
8
2,0
7
1,6
400
300
1,2
12
2
11
0,8
200
16
10
15
0,4
100
6
14
1000
0
1000
498
2000
2000
3000
3000
4000
5000
4000
6000
7000
[CFM]
8000
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
1120
3.08
4.60
87
49
A
3
1160
2.60
3.90
85
57
A
4
1220
1.53
2.30
79
58
A
5
—
—
—
—
—
A
6
1000
2.16
3.20
84
49
A
7
1020
1.81
2.70
82
57
A
8
1060
1.02
1.70
75
58
A
9
—
—
—
—
—
A
10
780
1.05
1.70
78
49
A
11
790
0.87
1.50
75
57
A
12
820
0.51
1.10
68
58
A
13
—
—
—
—
—
A
14
520
0.35
0.80
67
49
A
15
530
0.31
0.70
64
57
A
16
550
0.19
0.50
57
58
3
500
P1
[kW]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
R3G 400-AT01 -03
30.0
Inlet nozzle
Flange
40010-2-4013
10052-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Depth of screw 20-25 mm
Scroll housing used:
220
20
233
30˚
30
30˚ 30˚
250
499
Inlet nozzle
p. 552
Electr. connection
p. 608
Contacts
268
288
˚
30
˚
30˚
331
Technology
65
˚
25˚
355
30˚
30
˚
380
316
408
437
228
30˚
View Z
Accessories
Housing width
308
Cable gland
EC centrifugal fan
single inlet, Ø 450
Perm. amb. temp.
Electr. connection
VAC
Hz
rpm
kW
A
Pa
°C
p. 608
50/60
890
2.65
4.50
300
-25 to +50
M)
3~ 380-480
A
subject to alterations
Min. back pressure
M3G 150-NA
Max. current
draw (1)
R3G 450
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
(1) Nominal data in operating point with maximum load and 400 VAC
n
[rpm]
A
2
[Pa]
[in H O]
Curves
500
4
2,4
600
2,0
700
2,8
800
8
1,6
400
3
300
1,2
7
2
11
0,8
200
10
0,4
100
16
15
14
0
1000
2000
500
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
—
—
—
—
—
A
2
890
2.65
4.50
82
60
A
3
920
2.26
3.50
80
66
A
4
970
1.80
2.80
76
70
A
5
—
—
—
—
—
A
6
790
1.82
3.20
79
60
A
7
810
1.58
2.80
76
66
A
8
840
1.17
2.20
74
70
A
9
—
—
—
—
—
A
10
610
0.83
1.60
71
60
A
11
620
0.73
1.50
68
66
A
12
630
0.54
1.10
66
70
A
13
—
—
—
—
—
A
14
410
0.27
0.70
60
60
A
15
420
0.23
0.60
57
66
A
16
420
0.18
0.50
54
70
12
6
P1
[kW]
General
information
Line undervoltage / phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
kg
R3G 450-AR03 -03
31.5
Inlet nozzle
Flange
45010-2-4013
10053-2-4017
View with flange
EC-SYSTEMS
EC centrifugal,
forward
View without flange
EC centrifugal, backward for clean rooms
Mass of
centrifugal fan
Centrifugal fan
AC centrifugal,
backward
•
•
•
•
•
AC centrifugal,
forward
Slave output 0-10 V max. 3 mA
Output 20 VDC (±20 %) max. 50 mA
Output 10 VDC (+10 %) max. 10 mA
RS485 ebmBUS
Alarm relay
EC centrifugal,
backward
– Technical features:
•
• PFC (passive)
•
• Integrated PID controller
•
• Control input 0-10 VDC / PWM
•
• Input for sensor 0-10 V or 4-20 mA
•
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Depth of screw 20-25 mm
Scroll housing used:
247
22
262
30˚
30
30˚ 30˚
281
501
Inlet nozzle
p. 552
Electr. connection
p. 608
Contacts
301
323
˚
30
˚
30˚
371
Technology
65
˚
25˚
398
30˚
30
˚
427
355
458
491
255
30˚
View Z
Accessories
Housing width
346
Cable gland
EC centrifugal blowers
dual inlet, Ø 133
Voltage range
Air flow
Speed/rpm
Power input
Current draw
Sound pressure level
Min. back pressure
Perm. amb. temp.
Electr. connection
VDC
VDC
m3/h
rpm
W
A
dB(A)
Pa
°C
p. 600
A
24
16-28
700
1780
105
5.60
62
50
-25 to +60
G)
A
48
36-57
700
1780
105
2.80
62
50
-25 to +60
G)
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
D1G 133
M1G 074-BF
D1G 133
M1G 074-BF
subject to alterations
n
[rpm]
2
[Pa]
500
A
2,0
600
[in H O]
Curves
4'
UN
UR
300
1,0
4
3'
8
200
3
0,5
7
2'
2
100
6
0
100
200
502
200
5
400
300
400
600
1
[CFM]
800
[m3/h]
LpA
[dB(A)]
tL
[%]
A
1’
—
—
—
—
A
2’
2050
121
63
49
A
3’
2490
106
62
41
A
4’
2820
100
62
37
A
1
1780
105
62
—
A
2
1900
97
61
49
A
3
2310
86
59
41
A
4
2630
80
60
37
A
5
1500
73
59
—
A
6
1720
67
57
49
A
7
2020
58
56
41
A
8
2230
49
56
37
1,5
400
P1
[W]
General
information
kg
D1G 133-AB29 -52
3.3
D1G 133-AB39 -52
3.3
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA; A (48 VDC) with CCC
215
EC centrifugal,
forward
170,5
14
5
79
6
EC-SYSTEMS
85
180
Ø112
65,5
71
87
Accessories
190
Technology
Brass lead tips
503
Guard grille
p. 555
Electr. connection
p. 600
Contacts
300 +20
EC centrifugal blowers
dual inlet, Ø 133
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
D1G 133
M1G 074-CF
A
24
16-28
1020
1580
118
6.00
64
D1G 133
M1G 074-CF
A
48
36-57
1020
1580
118
3.00
64
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
1,5
400
300
1,0
4
3'
8
200
3
0,5
7
2'
100
2
6
5
0
200
200
504
400
400
600
800
1
600
1000
1'
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1700
145
65
—
A
2’
1930
133
62
38
A
3’
2290
122
59
41
A
4’
2700
99
61
32
A
1
1580
118
64
—
A
2
1790
107
61
38
A
3
2100
95
57
41
A
4
2410
73
58
32
A
5
1400
78
60
—
A
6
1580
70
56
38
A
7
1760
56
53
41
A
8
2000
44
53
32
UR
4'
UN
n
[rpm]
General
information
kg
D1G 133-DC13 -52
3.4
D1G 133-DC17 -52
3.4
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA
232
EC centrifugal,
forward
max. 204
EC-SYSTEMS
67,5
93,5
85
max. 214
Ø112
104
96
14
5
6
Accessories
190
Technology
Brass lead tips
505
Guard grille
p. 555
Electr. connection
p. 600
Contacts
300 +20
EC centrifugal blowers
dual inlet, Ø 146
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
D1G 146
M1G 074-CF
A
24
16-28
1000
1350
105
5.10
61
D1G 146
M1G 074-CF
A
48
36-57
1000
1350
105
2.60
61
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
A
2
[Pa]
[in H O]
Curves
1,5
4'
1,0
300
4
UN
3'
200
3
0,5
8
7
2'
2
100
6
5
0
200
200
506
400
400
600
800
1'
1
600
1000
[CFM]
[m3/h]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1460
129
63
—
A
2’
1680
119
60
53
A
3’
1890
111
58
61
A
4’
2240
95
59
55
A
1
1350
105
61
—
A
2
1570
95
58
53
A
3
1750
88
56
61
A
4
2010
70
57
55
A
5
1210
70
56
—
A
6
1360
60
54
53
A
7
1460
53
52
61
A
8
1670
42
51
55
400
UR
n
[rpm]
General
information
kg
D1G 146-AA19 -52
3.5
D1G 146-AA33 -52
3.5
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA
232
max. 104,5
EC-SYSTEMS
219
14
5
98
6
69
96
Ø117-0,5
85
EC centrifugal,
forward
max. 206
Accessories
180
Technology
Brass lead tips
507
Guard grille
p. 555
Electr. connection
p. 600
Contacts
350 +20
EC centrifugal blowers
dual inlet, Ø 160
Power input
Current draw
Sound pressure level
Motor
VDC
m3/h
rpm
W
A
dB(A)
D1G 160
M1G 074-CF
A
24
16-28
980
1250
112
5.60
60
D1G 160
M1G 074-CF
A
48
36-57
980
1250
112
2.90
60
Electr. connection
Speed/rpm
Type
Perm. amb. temp.
Air flow
Nominal data
Min. back pressure
Voltage range
VDC
Curve
Nominal voltage
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 600
0
-25 to +60
G)
0
-25 to +60
G)
subject to alterations
2
[Pa]
A
2,0
500
[in H O]
Curves
1,5
400
4'
UR
UN
300
1,0
4
3'
8
200
3
0,5
7
2'
100
6
2
5
0
200
200
508
400
400
600
800
1
1'
600
[CFM]
1000
[m3/h]
n
[rpm]
P1
[W]
LpA
[dB(A)]
tL
[%]
A
1’
1330
142
63
—
A
2’
1520
128
61
64
A
3’
1790
115
59
66
A
4’
2090
105
60
60
A
1
1250
112
60
—
A
2
1420
102
59
64
A
3
1660
92
58
66
A
4
1900
80
58
60
A
5
1100
75
58
—
A
6
1250
69
56
64
A
7
1420
58
54
66
A
8
1580
47
53
60
General
information
kg
D1G 160-DA19 -52
3.6
D1G 160-DA33 -52
3.6
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Tach output
• Control input 0-10 VDC / PWM
• Reverse polarity and locked-rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA
EC centrifugal,
forward
max. 226
102
5
17
max. 242
EC-SYSTEMS
6
100,5
85
Ø
Brass lead tips
Ø130 ±0,5
87
max. 107
max. 176,5
509
Guard grille
p. 555
Electr. connection
p. 600
Contacts
Technology
Accessories
400 +20
EC centrifugal blowers
dual inlet, Ø 146
W
A
50/60
1740
171
1.30
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 200-277
A
subject to alterations
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
D3G 146
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
[Pa]
[in H O]
Curves
1,5
1,0
3
8
200
7
0,5
2
12
6
100
11
10
0
100
200
510
9
400
300
200
400
600
5
500
800
600
1000
1
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1740
171
1.30
67
—
A
2
1960
169
1.20
65
49
A
3
2150
165
1.20
65
56
A
4
2410
166
1.20
66
55
A
5
1460
103
0.70
62
—
A
6
1650
102
0.80
60
46
A
7
1820
104
0.80
60
53
A
8
2020
102
0.70
61
52
A
9
1090
47
0.40
55
—
A
10
1220
46
0.40
56
41
A
11
1330
46
0.40
52
47
A
12
1480
46
0.40
53
44
400
300
P1
[W]
A
A
4
n
[rpm]
General
information
kg
D3G 146-AH50 -01
4.0
EC centrifugal, backward for clean rooms
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
max. 206
219
232
EC centrifugal,
forward
max. 104,5
50
27
96
Ø5
5
98
EC-SYSTEMS
Ø117-0,5
350+20
511
Guard grille
p. 555
Electr. connection
p. 603
Contacts
Technology
Accessories
Core-end sleeves
EC centrifugal blowers
dual inlet, Ø 160
subject to alterations
rpm
W
A
50/60
1390
154
1.20
1~ 200-277
A
Electr. connection
Hz
Perm. amb. temp.
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
D3G 160
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
0,75
200
3
160
120
7
80
2
0,25
12
11
6
40
10
9
0
100
200
512
300
200
400
400
600
500
800
5
600
1000
1
[CFM]
[m3/h]
I
[A]
LpA
[dB(A)]
tL
[%]
1
1390
154
1.20
64
—
2
1440
129
1.00
61
53
A
3
1540
93
0.70
57
60
A
4
1590
63
0.50
56
47
A
5
1180
96
0.70
59
—
A
6
1220
79
0.60
56
52
A
7
1270
54
0.40
52
57
A
8
1310
37
0.30
51
44
A
9
860
40
0.30
51
—
A
10
890
34
0.30
47
45
A
11
910
24
0.20
43
45
A
12
930
18
0.20
42
31
0,5
8
P1
[W]
A
240
4
n
[rpm]
A
A
1,0
[Pa]
[in H O]
Curves
General
information
EC centrifugal, backward for clean rooms
EC centrifugal,
forward
EC-SYSTEMS
4.9
Core-end sleeves
Accessories
D3G 160-BF60 -01
Technology
kg
513
Guard grille
p. 555
Electr. connection
p. 603
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
EC centrifugal blowers
dual inlet, Ø 180
W
A
50/60
1090
165
1.22
Electr. connection
rpm
Perm. amb. temp.
Hz
1~ 200-277
A
subject to alterations
VAC
Min. back pressure
M3G 074-CF
Max. current
draw (1)
D3G 180
Max. power
input (1)
Motor
Speed/rpm
Type
Frequency
Nominal data
Nominal
voltage range
Curve
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Galvanised
Electronics enclosure: Die-cast aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal; rotor on top or rotor on bottom on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
p. 603
-25 to +60
J1)
0
(1) Nominal data in operating point with maximum load and 230 VAC
2
[Pa]
4
0,75
200
3
150
0,50
8
n
[rpm]
P1
[W]
I
[A]
LpA
[dB(A)]
tL
[%]
A
1
1090
165
1.22
64
—
A
2
1200
155
1.15
62
54
A
3
1310
113
0.85
59
62
A
4
1400
74
0.55
56
53
A
5
925
101
0.75
60
—
A
6
1015
95
0.70
58
51
A
7
1090
67
0.50
54
61
A
8
1145
45
0.35
51
48
A
9
690
43
0.35
52
—
A
10
760
42
0.30
50
47
A
11
805
31
0.25
46
51
A
12
840
21
0.20
43
39
A
13
455
15
0.15
40
—
A
14
500
15
0.15
38
36
A
15
525
12
0.10
34
35
A
16
545
9
0.10
32
23
A
1,00
250
[in H O]
Curves
7
100
12
0,25
2
11
50
6
16
10
15
14
13
0
250
400
514
9
500
800
1
[CFM]
5
750
1200
1600
[m3/h]
General
information
7.0
EC centrifugal, backward for clean rooms
D3G 180-AB62 -01
309
255
180
296
7
133
EC centrifugal,
forward
kg
136
90
EC-SYSTEMS
1
600
Core-end sleeves
Accessories
3,2
92
255
Technology
333
˚
Ø 149
60
134
289
6x
188
168
5˚
515
Guard grille
p. 555
Electr. connection
p. 603
Contacts
Centrifugal blower
without flange
EC centrifugal,
backward
Mass of
centrifugal blower
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features:
• Output 10 VDC max. 1.1 mA
• PFC (passive)
• Tach output
• Control input 0-10 VDC / PWM
• Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: UL, CSA; CCC, GOST are applied for
516
General
information
Switch power supplies
522
External commutation electronics for rail technology
526
Accessories: Temperature sensor / control module, pressure control, selection module, interface converter, ...
528
HMS controller
546
AC centrifugal,
backward
518
517
Contacts
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Options
AC centrifugal,
forward
EC-SYSTEMS
EC-SYSTEMS
Options
EC fan
PWM and Lin 0-10 VDC
red
Linear input:
< 1 VDC
1 VDC
10 VDC
24 / 48 VDC
blue
Control input
Lin
yellow
0-10 VDC
EC fans 24 / 48 VDC
with integrated commutation electronics
-> n=0
-> nmin
-> nmax
PWM
PWM input:
< 10% PWM -> n=0
10% PWM -> nmin
100% PWM -> nmax
white
Tach output
Power supply 230 VAC / 48 VDC
EC fan 48 VDC
PWM and Lin 0-10 VDC
Linear input:
< 1 VDC
1 VDC
10 VDC
red
230 VAC, 50 / 60 Hz
blue
yellow
Optional board (built-in):
3 speed steps
Control input
Lin 0-10 VDC or
selector switch
Constant air flow
PC with interface
converter (RS485)
RS485 / ebmBUS
Commutation electronics 650 W
110 VDC
PC with interface
converter (RS485)
Actual value 0-10 VDC
(e.g. pressure, temperature, air flow,
air speed, moisture, CO2)
Control input
Lin
0-10 VDC
Potentiometer for set values
Tach output
Alarm
Controller enabling 10-100 VDC
10-253 VAC
518
-> n=0
-> nmin
-> nmax
PWM input:
< 10% PWM -> n=0
10% PWM -> nmin
100% PWM -> nmax
white
Selector switch
EC fans 48 VDC
with integrated commutation electronics
EC fan
EC fans
with external commutation electronics
650 W, 110 VDC (rail technology)
General
information
EC fans (motor size 055)
with integrated commutation electronics
1~ 115 VAC or 230 VAC
50/60 Hz mains operation
AC centrifugal,
backward
EC fan with integrated electronics
AC centrifugal,
forward
EC fans (motor size 074)
with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC
50/60 Hz mains operation
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
EC centrifugal,
backward
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
Supply for potentiometer 10 V
Tach output
EC fans (motor size 084)
with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC
50/60 Hz mains operation
EC centrifugal,
forward
EC fan with integrated electronics
EC centrifugal, backward for clean rooms
Slave output
Mains operation, 50 / 60 Hz
EC-SYSTEMS
PC with interface
converter (RS485)
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
Supply for potentiometer 10 V
Accessories
Alarm
519
Contacts
Technology
Slave output
EC-SYSTEMS
Options
EC fan with integrated electronics
EC fans (motor size 084, ebmBUS)
with integrated commutation electronics
1~ 200-277 VAC,
50/60 Hz mains operation
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
on/off and alarm
output 15 V
EC fan with integrated electronics
Mains operation, 50 / 60 Hz
PC with interface
converter (RS485)
Control input 0-10 VDC / PWM
Actual value input 0-10 VDC
Actual value input 4-20 mA
Supply for external sensor 20 V
Supply for potentiometer 10 V
Alarm
Slave output
520
EC fans (motor size 112/150)
with integrated commutation electronics
1~ 200-277 VAC or
3~ 200-240 / 380-480 VAC
50/60 Hz mains operation
General
information
Electronics
EC fan
EC-SYSTEMS:
Networked EC fans with interface
converter and repeater
AC centrifugal,
backward
Interface converter
and repeater
Control software
part no.
25711-2-0199
integrated electronics
max. 31
addresses
Power supply 150 W
– Individual control
and monitoring of
max. 7,905 fans
Repeater
part no.
25708-1-0174
EC centrifugal,
backward
Features of control
software LISA 5.1
AC centrifugal,
forward
Interface converter
part no. 21487-1-0174
– Group-oriented
arrangement of the fans
– Level 2: Overview
display for 255 groups
max. 31
addresses
integrated electronics
EC centrifugal, backward for clean rooms
– Level 1: Overview
display for 10 floors
– Level 3: Overview
display for 31 fans
within a group
– Broadcast command for
a group or all fans
– Speed, temperature or
pressure control
EC centrifugal,
forward
– Alarm signal
integrated electronics
Repeater
Technology
Accessories
EC-SYSTEMS
max. 31
addresses
521
Contacts
Customer PC with LISA
5.1 control software
Switch power supply with PFC, basic version
48 VDC, 150 W / 300 W
Output voltage
Output
P1 max.
Rated output current
Mass
Type
Frequency
Nominal data
Nominal voltage
– General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
– Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
– Material: Housing made of stainless steel
– Protection class: I
– Type of protection: IP 20 (acc. to EN 60529)
VAC
Hz
VDC
W
A
kg
a
b
c
d
e
f
Dimensions
CNW015-AB06 -01
1~ 115
50/60
48
150
3.10
0.7
187
176
167
50
110
1
CNW015-AB02 -01
1~ 230
50/60
48
150
3.10
0.7
187
176
167
50
110
1
CNW030-AC06 -01
1~ 100-120
50/60
48
300
6.25
1.3
272
260
251
66
112
2
CNW030-AC02 -01
1~ 200-277
50/60
48
300
6.25
1.3
272
260
251
66
112
2
subject to alterations
f
d
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
– Product conforming to standards: EN 50178, CE
– Approvals: UL/CSA (File No. E 181381)
e
80
108
522
10
a
c
b
5
blue
red
EC centrifugal, backward for clean rooms
red
EC centrifugal,
forward
PE
EC-SYSTEMS
N
Accessories
L
Technology
+48 GND +48 GND
V
V
blue
EC centrifugal,
backward
Line side
Motor side
AC centrifugal,
forward
AC centrifugal,
backward
Blower 2
exhaust air
523
Contacts
Blower 1
exhaust air
General
information
Switch power supply with PFC, RS485 and ebmBUS
48 VDC, 150 W / 300 W
Output voltage
Output
P1 max.
Rated output current
Mass
Type
Frequency
Nominal data
Nominal voltage
– General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
– Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
– Material: Housing made of stainless steel
– Protection class: I
– Type of protection: IP 20 (acc. to EN 60529)
VAC
Hz
VDC
W
A
kg
Dimensions
a
b
c
d
e
f
CNW015-AB06 -05
1~ 115
50/60
48
150
3.10
0.7
187
176
167
50
110
1
CNW015-AB02 -05
1~ 230
50/60
48
150
3.10
0.7
187
176
167
50
110
1
CNW030-AC06 -05
1~ 100-120
50/60
48
300
6.25
1.3
272
260
251
66
112
2
CNW030-AC02 -05
1~ 200-277
50/60
48
300
6.25
1.3
272
260
251
66
112
2
subject to alterations
f
d
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-1
– Product conforming to standards: EN 50178, CE
– Approvals: UL/CSA (File No. E 181381)
– Technical features: Control board for RS485, ebmBUS and LISA functions
e
80
108
524
10
a
c
b
5
N
PE
red
+48 GND +48 GND
V
V
blue
EC centrifugal,
backward
RS485
EC centrifugal, backward for clean rooms
L
Tach PWM
EC centrifugal,
forward
Motor side
EC-SYSTEMS
Line side
Accessories
white
Technology
yellow
RS485
AC centrifugal,
forward
RS485
Interface converter
AC centrifugal,
backward
Blower
525
Contacts
To next switch
power supply
~
RS232
2 x RJ45:
PIN 5 - RS B
PIN 6 - RS A
General
information
External commutation electronics
for rail technology, 110 VDC, 650 W
Nominal voltage
Power input
P1 max.
Current draw
Perm. amb. temp.
Mass
– General remarks: For EC motors / fans with three cores and without integrated
commutation electronics
– Function: Commutation unit for three-core ebm EC motors up to a power input of 650 W.
Various basic functions are integrated: open loop speed control, closed loop speed control,
even an RS485 interface. In combination with sensors, all control tasks as required in air
technology can be executed.
– Protection class: I
– Type of protection: IP 20 (acc. to DIN EN 60529)
– NB: Connected fans have to be designed for rated voltage of 127 VDC!
Type
VDC
W
A
°C
kg
CEG 485-HB50 -01
110
650
Nominal data
5.9 -25 to +40 2.0
subject to alterations
68
2,2
169
1,5
190
64
63
1,5
40
146,5
526
193
5,5
63
179,5
– EMC / EMI: Acc. to EN 50155 and EN 50121
– Legislation: Low voltage directive 73/23/EEC, VDE 0160/EN 50178
– Design:
• motor output protected against short circuit phase to phase and conditionally
phase to earth
• 0-10 V input (Ri: 100 k)
• 0-10 V input (Ri: 100 k) for connection of external actual value input
• RS485 interface (ebmBUS)
• Floating alarm contact 250 VAC / 5A, during alarm, relay is released (low-active)
• Wide voltage input for external controller enabling via RESET function
• Tach output
• LED for operation and alarm mode
green: unit on
red: alarm
• Setting of minimum and maximum values via potentiometer
• Operational modes (to be set via DIP switch):
Open loop speed control
Closed loop speed control
Controlling external parameters
• Direction of motor rotation reversible
– Connectors for external electronics:
KL1 2-pole connector; centreline 7.5; Co. Wago part no.: 231-202/026-000
KL2A 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
KL2B 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
KL3A 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL3B 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL4 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL5A 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL5B 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL6 3-pole connector; centreline 7.5; Co. Wago part no.: 731-603
General
information
AC centrifugal,
backward
An
GND
NO
COM
KL2A
KL3A
EN
+
H+
H1
H2
EN
-
KL4
H-
H-
H3
U
KL5A
Connector Connection Assignment / function
Connector Connection Assignment / function
PE1
Ground connection
KL3A
PE2
Ground connection
KL1
KL2A
KL2B
KL3B
Relay contact for alarm, make for failure
Relay contact for alarm
NC
Relay contact for alarm, break for failure
COM
Relay contact for alarm
EN +
Enable input via RESET function
EN -
Enable input via RESET function
H1
Hall-sensor 1
-
110 VDC
RS A
Interface connection RS A
RS B
Interface connection RS B
RS A
Interface connection RS A
RS B
Interface connection RS B
H2
Hall-sensor 2
An, Tacho
Tach output, open collector
H3
Hall-sensor 3
GND
Reference KL2 (for KL2 only)
+18 V
+18 V (non-stabilised, +20 %, 20 mA) to supply
Sensor 1
external sensors
Input for external sensor, Ri = 100 k
GND
+10 V
W
KL6
COM
110 VDC
KL5A
V
NO
+
KL4
AC centrifugal,
forward
Tacho
COM
EC centrifugal,
backward
RS
B
NC
PE2
EC centrifugal, backward for clean rooms
KL1
RS
A
GND
TW
H+ PTC
EC centrifugal,
forward
RS
B
GND
0-10
V
Shielding connection
EC-SYSTEMS
RS
A
1
+10
V
Shielding connection
KL5B
H+
Power supply for hall-sensors (+)
H+
Power supply for hall-sensors (+)
Reference KL2 (for KL2 only)
TW / PTC
Thermal switch or PTC connection
H-
Power supply for hall-sensors (-)
0-10 V
+10 V (stabilised +/- 3 %, 25 mA)
Input for set value 0 - 10 V, Ri = 100 k
H-
Power supply for hall-sensors (-)
GND
Reference KL2 (for KL2 only)
U
Motor winding U
V
Motor winding V
W
Motor winding W
KL6
Accessories
-
Sensor
KL5B
Technology
+
+18
V
KL3B
527
Contacts
KL2B
PE1
Output current
Output impedance
Temperature
measuring range
Mass
50005-1-0174
Output voltage
Part no.
Current draw
Nominal data
Nominal voltage
Temperature sensor
VDC
mA
VDC
mA
k
°C
kg
15-30
10
0-10
1.0
1.1
-20 to +80
0.02
subject to alterations
3 +0,2
1±0,1
2,5
– Electr. connection:
Ø4,9
red
15-30 VDC
8
3,3
Ø7 +0,5
Ø3,5
84,7
yellow
0-10 VDC
output
45
37,5
38,5
Output
+
–
(yellow)
(red)
(blue)
Core-end sleeve
450 +20
6,9
5
13
6,5
blue
6
85
Temperature sensor
– Output voltage depending on temperature:
U/V
10
0
-20
Tolerance ±3 K
528
80
Temp. °C
Output current
Output impedance
Temperature
control range
Mass
VDC
mA
k
°C
kg
50002-1-0174
18-60
10
2-10
0.1
6.8
+30 to +55 0.02
50003-1-0174
18-60
10
0-10
0.1
6.8
+10 to +45 0.02
General
information
EC centrifugal,
backward
Output voltage
mA
Part no.
EC centrifugal, backward for clean rooms
Current draw
VDC
Nominal data
subject to alterations
3 +0,2
Ø4,9
red
18-60 VDC
84,7
yellow
2-10 VDC
or 0-10 VDC
output
45
37,5
red
Maximum ripple
± 3.5 %
yellow
Control input
0 - 10 VDC
Counter
47 K
Isink max.
10 mA
6,5
5
Core-end sleeve
EC-SYSTEMS
(yellow)
(red)
(blue)
680 Tach output,
pulses per revolution
Speed display
450 +20
38,5
47 V
blue
blue
GND
6
85
Fans
Accessories
Connection
– Control function: Both designs have "cooling" as control function
U/V
U/V
10
10
2
1
0
30
55
50002-1-0174
Temp. °C
0
6
10
45
Temp. °C
50003-1-0174
Technology
Temperature control module
Tolerance ±3 K
529
Contacts
Output
+
–
white
Alarm
6,9
13
Controller
47 K
1±0,1
2,5
– Electr. connection:
8
3,3
Ø7 +0,5
Ø3,5
EC centrifugal,
forward
Nominal voltage
AC centrifugal,
forward
AC centrifugal,
backward
Temperature control module
Pressure control with integrated pressure sensor
Pressure control
range
Perm. amb. temp.
CCC 000-AC04 -01
Nominal voltage,
alternative
Type
Frequency
Nominal data
Nominal
voltage range
– Functions: Integrated PID controller, day/night/linear set point preset, integrated
set point potentiometer for day and night, external set point preset via potentiometer
– Pressure sensor: 0-500 Pa, bursting strength 200 mbar, for non-aggressive
gaseous media
– Type of protection: IP 55
– Inlet nozzles: Suitable inlet nozzles to determine airflow, see page 551
VAC
Hz
VDC
Pa
°C
50/60
20 @ 50 mA
50-500
-25 to +60
1~ 100-277
subject to alterations
35,5
89,5
167
1,5
10,5
162
195
95±0,2
115
pressure controller
100-277 VAC
pressure range
IP55
50/60 Hz
0-500 Pa
10
125
43
180±0,4
Ø 5,5
7,5
530
General
information
AC centrifugal,
backward
Fan
Set value
potentiometer
Selector switch
Day
Linear
Night
Alarm
ST8
GND
Night
GND
Day
GND
+10 V
0-10 V
PWM
GND
OUT
Tach
GND
PE
Protective earth
ST3
L
Mains 50/60 Hz, phase
N
Mains 50/60 Hz, neutral
PE
Protective earth
L
20 V IN
EC centrifugal, backward for clean rooms
Connector Connection
Assignment / function
DC voltage supply (optional),
GND
Tach
Tach output from fan
Mains 50/60 Hz, phase
OUT
Control voltage for fan, 0-10 V
N
Mains 50/60 Hz, neutral
GND
GND
NC
Relay contact for alarm, break for failure
+10 V
Set value potentiometer,
COM
Relay contact for alarm
NC
Relay contact for alarm, break for failure
0-10 V PWM
Set value potentiometer
COM
Relay contact for alarm
GND
Set value potentiometer
Day
Selector switch terminal
GND
Selector switch terminal
Night
Selector switch terminal
GND
Selector switch terminal
ST4
EC centrifugal,
forward
with reverse polarity protection
GND
supply 10 V (-10 %), 10 mA
EC-SYSTEMS
ST7
Assignment / function
Accessories
ST2
ST4
Technology
ST1
ST3
Line terminals
Control terminals
Connector Connection
20 V IN
COM
ST8
EC centrifugal,
backward
ST7
NC
COM
NC
N
L
ST2
531
Contacts
ST1
PE
N
L
PE
AC centrifugal,
forward
Mains
Selection module for 3 speeds
– General remarks: Using an external selector switch, one of three preset speeds
can be chosen. Presetting is done via one integrated potentiometer each.
– Material: Plastics
– Type of protection: IP 20
Type
CBC 000-AE04 -01
subject to alterations
90
24
50
532
EC centrifugal,
backward
Connection
selector switch
+10 V
Day
Night
AC centrifugal,
forward
GND
EC centrifugal, backward for clean rooms
0-10 V output
blue
EC centrifugal,
forward
yellow
EC-SYSTEMS
+10 V
Accessories
Selector switch
red
Technology
Fan
AC centrifugal,
backward
Connection
fan
533
Contacts
– Electr.
connection:
Party
General
information
Interface converter RS232 - RS485
21487-1-0174
1~
230
VAC / VDC mA
12-24
150
Mass (incl. PS)
VAC
Current draw at
no-load operation
Part no.
Supply voltage
Nominal data
Nominal voltage
power supply
– General remarks: This interface converter permits bi-directional connection of
RS232 devices (laptop or PC) with ebmBUS devices (electronic commutation units with
RS485 interface)
– Safety: Electrical insulation between the RS232 and RS485 side is provided
– Material: Plastic housing for standard rail mounting according to DIN EN 50022-35
– Status display: Via LEDs
green: supply voltage OK
red: data exchange
kg
0.4
subject to alterations
RS485
M L+
105
22
RS232
75
534
– Mode of operation: RS485 2-wire mode with echo and automatic control
– Galvanic insulation: Min. 1kV insulation voltage between RS232 and RS485 interfaces and
between power supply and interfaces
– ESD immunity: Up to 15 kV (acc. to IEC 801-2, Stage 4)
– Delivery scope: • Interface converter
• Plug-in supply unit (230 VAC / 12 VDC, 500 mA)
• Adaptor leads with 2 x 9-pole SUB-D sockets
• Adaptor leads with 9-pole SUB-D socket
• Screw terminal RS485
General
information
Interface converter RS232 - RS485
Nominal data
Part no.
kg
21495-2-0174
0.1
EC centrifugal, backward for clean rooms
Mass
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– General remarks: This interface converter permits bi-directional connection of
RS232 devices (laptop / PDA) with ebmBUS devices (electronic commutation units with
RS485 interface) Power supplied by RS232 of the laptop / PDA.
– Material: Plastic housing
– Status display: Via LEDs
PWR: Power supply
TXD: Data transfer (send)
RXD: Data transfer (receive)
TX+ TX- GND RX+ RX-
19
subject to alterations
74
RS485
RS422
EC centrifugal,
forward
TRX+ TRX-
– Mode of operation: RS485 2-wire mode with echo and automatic control
– Delivery scope: Interface converter, English-language operating manual
– Electrical terminals: Screw terminal, TRX+ = RSA, TRX– = RSB
RXD
TXD
EC-SYSTEMS
PWR
535
Contacts
Technology
Accessories
37
RS485 repeater
Perm. operating temp.
Perm. storage temp.
Mass
25708-1-0174
Power input
Part no.
Frequency
Nominal data
Supply voltage
– General remarks: The physical RS485 repeater is used for the connection of two segments
on an RS485 basis. It can split a segment with network bus wires that are too long, or with
too many nodes into two smaller, standardised units. A maximum of 31 nodes can be
connected to the repeater.
– Installation: The repeater housing is mounted on the wall or in the cable duct with two
screws (Ø 4 mm) or with cable ties.
– Material: Housing made of galvanised sheet steel
– Type of protection: IP 20 according to DIN EN 60529
VAC
Hz
VA
°C
°C
kg
50/60
<3
1~ 200-277
0 to +50 -20 to +70
0.3
subject to alterations
–
–
–
–
–
Wieland Bamberg
screw terminal
Bus2
Bus1
Mating connector
GST 18/3
Bus2
Bus1
50
38
Type of transceiver: 2 x ANSI standard RS485 transceiver
Galvanic insulation: Operating insulation 500 V between both channels
Network connection: Screw terminals
Mains connection: Wieland connector GST 18/3 (part of delivery)
Pin configuration of network:
8765432 1
8765432 1
A A
B B
BUS1
BUS2
Pin No.
Assignment / function
1-4
not assigned
5
Connection RS485, line B
6
Connection RS485, line B
7, 8
not assigned
(each looped through within BUS1 and BUS2)
190
200
12 3 4 5 6 7 8
3
LED
30
Ø4
.3
Supply connection
536
12 3 4 5 6 7 8
General
information
RS485 terminal box with lead connections
for centrifugal fans with EC motor size 084 (ebmBUS, RS485)
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– General remarks: RS485 terminal box with
• 2x RJ45 socket for ebmBUS
• ebmBUS lead with Molex Mini-Fit female connector to connect to motor
• 3-pole 4-pin unit connector with AMP Mate-N-Lock female connector to
connect to motor
• Mode of operation display (LED2 green) and alarm display (LED1 red)
– Delivery scope:
• Terminal box
• Supply line (800 mm)
• ebmBUS line (800 mm)
– Material: ABS (fire rating V0 according to UL)
EC centrifugal, backward for clean rooms
Part no.
54002-4-1040
subject to alterations
61.6
45.4
111
99
green/yellow
PE
black 2
N
black 1
L
– Pin configuration of ebmBUS lead:
Colour
Assignment / function
yellow
RS A
white
RS B
red
Operation: +15 V Alarm:
blue
Operation:
0V
0 V Alarm: +15 V
Mounting dimensions
Assignment / function
5
RS B
6
RS A
Technology
4
88
99
58
Pin No.
Accessories
– Pin configuration of RJ45 sockets:
61
537
Contacts
87
73
61
Assignment / function
EC-SYSTEMS
57
Colour
EC centrifugal,
forward
– Pin configuration of supply lead:
Hand-held control terminal
Perm. amb. temp.
Perm. storage temp.
Mass
CBC 000-AB06 -01
Supply voltage
Type
Frequency
Nominal data
Nominal voltage
range power supply
– General remarks: Terminal to control networked fans and to set their parameters;
RS485 (ebmBUS)
– Type of protection: IP 20 (acc. to DIN EN 60529)
– Protection class: III
– Display: Plain text LCD, 2x8 characters
– Accumulator and charging electronics: 2 x round cell R6 DIN 40863 NiMH 1,500 mAh,
operating time approx. 40 hrs, standby time approx. 100 days, charging time max. 4 hrs.
– Parts included in delivery: Hand-held control terminal, power supply and accumulator
unit, BUS cable, 2 x round cell R6 NiMH 1,500 mAh
VAC
Hz
VDC
°C
°C
kg
50/60
12
1~ 100-240
subject to alterations
95
68
538
44
0 to +45 -20 to +65 0.4
Contacts
539
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
General
information
Speed setting
with housing
Resistance
Perm. amb. temp.
Mass
VDC
mA
k
°C
kg
10
1.1
0-10 Lin
50
0.10
Supply voltage
Max. current draw
– Material: Housing made of plastic
– Type of protection: IP 54
– Design: The speed setting can be operated with the entire range of ebm-papst EC fans.
It is supplied with current via the fan's DC output and supplies a 0-10 V signal that allows
infinitely variable open loop speed control. The control also permits fan speed measurement
using a multimeter equipped with a frequency meter (for which a tach output is given from
the fan).
– Cable inputs: 4 x M16 or M20
– Mounting holes: Suitable for 4 mm mounts
Nominal data
Type
CLC 000-AE04 -01
subject to alterations
– Speed measurement: Connect a frequency meter to the connection points
(labelled + and -) on the PCB board. The fan outputs 1 pulse per revolution, so that
the measured frequency can be converted into rpm using the following equation:
rpm = frequency (Hz) x 60
– Comment:
• A single controller can be used to control multiple fans with the same speed setting.
• The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
• If the tach cable is required, this device can only be connected to a fan. Note that in rare
operating cases, it is possible that permanent connection of the tach cable can cause a
slight decrease in the maximum speed.
58
26
65
65
50
50
25
+ meter connection
– meter connection
540
EC centrifugal,
backward
Fan 1
AC centrifugal,
forward
Tacho
EC centrifugal, backward for clean rooms
GND
EC centrifugal,
forward
blue
white
white
Control
EC-SYSTEMS
red
yellow
blue
Accessories
blue
red
Technology
Fan 2
white
yellow
+10 V
Control
GND
Tacho
AC centrifugal,
backward
+10 V
541
Contacts
red
yellow
– Electr.
connection:
General
information
Speed setting
without housing
Resistance
Perm. amb. temp.
Mass
VDC
mA
k
°C
kg
10
1.1
0-10 Lin
50
0.05
Supply voltage
Max. current draw
– Design: The speed setting can be operated with the entire range of ebm-papst EC fans.
It is supplied with current via the fan's DC output and supplies a 0-10 V signal that allows
infinitely variable open loop speed control. The control also permits fan speed measurement
using a multimeter equipped with a frequency meter (for which a tach output is given from
the fan).
– Mounting hole: 10 mm
Nominal data
Type
CLC 000-AD04 -01
subject to alterations
36
28
12
22
50
36
28
4 x Ø3,5
+ meter connection
– meter connection
542
– Speed measurement: Connect a frequency meter to the connection points
(labelled + and -) on the PCB board. The fan outputs 1 pulse per revolution, so that
the measured frequency can be converted into rpm using the following equation:
rpm = frequency (Hz) x 60
– Comment:
• A single controller can be used to control multiple fans with the same speed setting.
• The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
• If the tach cable is required, this device can only be connected to a fan. Note that in rare
operating cases, it is possible that permanent connection of the tach cable can cause a
slight decrease in the maximum speed.
EC centrifugal,
backward
Fan 1
AC centrifugal,
forward
Tacho
EC centrifugal, backward for clean rooms
GND
EC centrifugal,
forward
blue
white
white
Control
EC-SYSTEMS
red
yellow
blue
Accessories
blue
red
Technology
Fan 2
white
yellow
+10 V
Control
GND
Tacho
AC centrifugal,
backward
+10 V
543
Contacts
red
yellow
– Electr.
connection:
General
information
LISA
Control software for EC-SYSTEMS
– Version: LISA 5.1
– Features:
• Individual control and monitoring of max. 7,905 fans
• Group-oriented arrangement of the fans
• Level 1: Overview display for 10 floors
• Level 2: Overview display for 255 groups within a floor
• Level 3: Overview display for 31 fans within a group
• Broadcast command for one group or all fans
• Speed, temperature or pressure control
• Error message
Part no.
25711-2-0199
subject to alterations
– Suitable for: EC motors and electronics with ebmBUS
– System requirements: Windows 2000 / XP
544
General
information
Fan Control
Control software & accessories for Pocket PCs / PDAs
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Version: Fan Control 1.00
– Features:
• Managing up to 31 fans
• Setting pre-set values and indicating actual values
• Setting parameters for PID control
• Setting fan address
• Setting mode of operation (heating/cooling)
• Alarm diagnosis
• Language selection for user interface
Graphic setting
Accessories
Fan address
Technology
Mode of operation
545
Contacts
Set and actual values
– Delivery scope: Installation-CD, interface converter (RS232-RS485), BUS cable,
installation instruction and detailed manual (PDF). The Pocket PC / PDA and compatible
serial communication cables are not included in the scope of delivery.
– Suitable for: EC motors and electronics with ebmBUS
– System requirements: Pocket PC / PDA with Windows Mobile 5.0, RS232 interface,
and serial communication cable.
– Compatible Pocket PCs / PDAs: (as of 2006-09-14)
• Hewlett-Packard rx1950
• Hewlett-Packard hx2190
• Fujitsu-Siemens Pocket Loox C550
• Dell Axim x51v (624 MHz)
Refer to our website at www.ebmpapst.com/downloads for a continuously updated list of
approved Pocket PCs / PDAs along with the suitable serial communication cables.
EC centrifugal,
forward
subject to alterations
EC-SYSTEMS
21500-1-0174
EC centrifugal, backward for clean rooms
Part no.
HMS controller
Supply voltage
Power input(1),
max.
Power input (2),
max.
Current draw(1),
max.
Perm. amb. temp.
Mass
– General remarks: The HMS controller is governed by a microprocessor and is specifically
designed for Heat Management Systems (= HMS). This controller allows for an almost limitless programming variety as regards customer-specific fan speed / temperature profiles.
Moreover, this controller offers a multitude of the most diverse alarm configurations.
Our HMS controller has been specially designed and adjusted to the product range of
ebm-papst in Mulfingen. Thus, any size of our fans or blowers can be used. The most
diverse of applications needing temperature-dependent control are possible. Among
these are applications in telecommunication and the IT industry, in refrigeration and
air-conditioning as well as in specific industrial plants and systems.
VDC
W
W
A
°C
kg
16-57
10
130
Nominal data
Type
CCC 000-AA05 -03
70
160
75.5
7.25
subject to alterations
546
0.175 -40 to +70 0.15
(1) without fans (2) per fan at nominal voltage
100
81
– Features:
• 4 fan speed / temperature characteristics that can be programmed independent
of each other
• 2 programmable no-frost relays for connection of 115 / 230 VAC heating devices
• 5 programmable alarm relays (with time lag):
– Temperature alarm (over- / under-temperature)
– Fan good / bad alarm programming
– Temperature sensor alarm
– Programmable depending on signal inputs
• 4 programmable status outputs (with time lag):
– With "open collector" design to connect optical or acoustic displays / alarms
– Each fan speed can be set individually
• 4 signal inputs for external switch
• Connection of two independent temperature sensors (NTCs) possible
• RS232 interface galvanic insulated
• Selective protection of each fan
• programming via Windows software
(terminal program version 15 ff.: part no. 25710-2-0199)
– Requirements:
• Supply voltage of HMS controller: 16-57 VDC
• Fans with standard interface
– 24 / 48 VDC fan voltage
– PWM / linear control input (0-10 V)
– Open collector tach output
• NTC with R25 = 33 k (EPCOS type M 891/33k/J)
• System requirements: Windows 2000 / XP
– Safety: According to EN 50178
– EMC / EMI: Interference immunity EN 61000, interference emission EN 50081-1
General
information
+
* / 250 V
PWM
Hall
F2 3,15 A
+
Heater 2
N
F7 10 A
Fan 3
Alarm 3
Alarm 2
K3
K4
+
K6
Fan 4
+
K7
Status
Alarm
contact
1 2 3 4
1 2 3 4
NTC 1
NTC 2
1
1
*
Hall
DTR
TD
GND
RTS
1
1
time lag fuse
ê
ê
PWM
Hall
F5 3,15 A
RD
1
PWM
F4 3,15 A
Alarm 5
Alarm 4
K5
Hall
F3 3,15 A
* / 250 V
N
Alarm 1
PWM
2 4 3 5 7
* / 250 V
* / 250 V
* / 250 V
* / 250 V
RS-232
electrically insulated
designation 9-pole Sub-D
0-57 V / 10 mA
EC centrifugal, backward for clean rooms
N
Fan 2
EC centrifugal,
forward
K2
-
EC-SYSTEMS
F6 10 A
Accessories
H2
* / 250 V
AC centrifugal,
forward
Fan 1
EC centrifugal,
backward
F1 3,15 A
Heater 1
Technology
H1
547
Contacts
K1
AC centrifugal,
backward
- +
16 - 57 VDC
L1
548
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Guard grilles
553
Lead connections, capacitors
558
Terminal boxes, air filters
562
Speed setting, motor protection switch, third-party accessories
564
549
AC centrifugal,
backward
550
AC centrifugal,
forward
Inlet nozzles
Contacts
General
information
Accessories
Inlet nozzles
o
– Material: Galvanised sheet steel
Vers. 2
Øk
Vers. 1
45˚
118
r1
Vers. 3
5
6x6
t
0˚
5
242
R14
2,8
Øs
Øu
4x90˚
24
3
4,
Øm
Øn
r3
r2
q
7
5,5
6x6
0˚
Inlet nozzles for backward curved centrifugal fans
Part no.
Size(1)
96120-2-4013
120
09566-2-4013
133
Vers.
k
m
(P)
1
146.0
94.4
(P)
1
129.0
87.0
09576-2-4013
175 / 190 (P)
1
170.0
09609-2-4013
220
(P)
2
96358-2-4013
225
(P)
1
96359-2-4013
250
(P/S)
96360-2-4013
97512-2-4013
31050-2-4013
310
o
q
r1
—
18.0
0.80
—
13.0
1.00
125.5
—
14.0
252.0
155.0
—
223.0
146.0
—
1
255.0
164.5
270 / 280 (S)
1
280.0
310
(P)
3
300.0
(A)
1
(2)
n
r2
r3
s
t
u
16.0
—
8.0
—
—
134.0
4x4.5
126.0
—
118.0
4x4.5
1.25
10.0
103.0
—
—
158.0
4x4.5
146.0
21.0
0.80
28.0
1.50
22.0
—
—
—
—
199.0
25.0
—
—
210.0
4x4.5
—
31.0
196.0
1.50
28.0
—
—
240.0
4x4.5
221.0
182.5
—
192.0
—
35.0
1.50
31.0
—
—
260.0
4x4.5
245.0
53.0
1.00
30.0
60.0
—
—
—
257.0
300.0
211.0
208.1
48.0
1.25
18.0
55.5
35.0
4x4.5
256.0
280.0
31051-2-4013
310
(A)
1
300.0
211.0
209.2
27.5
1.25
10.0
32.0
20.0
280.0
4x4.5
236.0
51357-2-4013
330 / 355 (P)
1
350.0
224.0
—
60.0
1.50
54.0
28.0
—
325.0
4x4.5
284.0
35560-2-4013
355
(A)
1
350.0
240.0
236.4
60.0
1.50
22.5
70.0
44.0
325.0
4x4.5
296.0
325.0
(2)
35561-2-4013
355
(A)
1
350.0
240.0
238.0
30.0
1.50
11.0
35.0
22.0
54476-2-4013
400
(A)
1
370.0
257.0
—
66.0
1.50
22.0
50.0
90.0 345.0
54478-2-4013
450
(A)
1
413.0
287.0
—
71.0
1.50
25.0
55.0
63045-2-4013
450
(A)
1
450.0
289.0
284.5
75.0
1.50
28.0
87.0
49.0
425.0
6x9
360.0
54480-2-4013
500
(A)
1
520.0
323.0
—
79.0
1.50
28.0
65.0
115.0
430.0
6x9
408.0
63072-2-4013
500
(A)
1
470.0
342.0
337.0
75.0
2.00
28.0
87.0
55.0
445.0
6x9
412.0
63071-2-4013
560
(A)
1
515.0
385.0
380.0
82.0
2.00
30.0
95.0
60.0
490.0
6x9
461.0
63070-2-4013
630
(A)
1
634.0
433.0
427.0
98.5
2.00
37.0
14.0
72.0
600.0
6x10.5 525.0
subject to alterations
550
(1) size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium (2) short inlet nozzle
100.0
390.0
4x4.5
267.0
4x4.5
322.0
6x9
362.0
k-value
For additional information, refer to p. 550
—
96400-2-4013
250
68
96359-2-4013
—
96410-2-4013
280
80
96360-2-4013
31100-2-4013
31080-2-4013
310
120
31050-2-4013
31110-2-4013
31090-2-4013
310
103
31051-2-4013
35600-2-4013
35580-2-4013
355
155
35560-2-4013
35610-2-4013
35590-2-4013
355
138
35561-2-4013
54515-2-4013
54500-2-4013
400
183
54476-2-4013
54514-2-4013
54510-2-4013
450
217
54478-2-4013
64015-2-4013
64005-2-4013
450
214
63045-2-4013
54518-2-4013
54516-2-4013
500
265
54480-2-4013
64025-2-4013
64002-2-4013
500
283
63072-2-4013
64030-2-4013
64001-2-4013
560
350
63071-2-4013
64040-2-4013
64000-2-4013
630
480
63070-2-4013
General
information
AC centrifugal,
backward
EC centrifugal, backward for clean rooms
Size
EC centrifugal,
forward
Part no. with 4 nozzles (Piezometer ring)
EC-SYSTEMS
Part no. with 1 nozzle
EC centrifugal,
backward
Inlet nozzles with measuring device to determine air flow for backward curved centrifugal fans
Technology
Accessories
subject to alterations
551
Contacts
D
0,5xD
Air flow measurement:
The differential pressure approach compares the static pressure before the
inlet nozzle with the static pressure inside the inlet nozzle.
Air flow can be calculated on the basis of the differential pressure (difference
in pressure of the static pressures) in keeping with the following equation:
V in [m3/h] and pW in [Pa]
V = k . pW
If constant air flow control is used, then the nozzle pressure has to be kept
constant:
pW = V2 : k2
k takes into account the specific nozzle characteristics.
1 or 4 pressure measuring points are spaced along the circumference of
the inlet nozzle. Connection on the customer side is accomplished via a
premounted T tube connector. This tube connector is suited for pneumatic
hoses with an internal diameter of 4 mm.
AC centrifugal,
forward
Inlet nozzles with pressure-measuring point for air flow measurement
Inlet nozzles
– Material: Galvanised sheet steel
Vers. 1
Vers. 2
106
Vers. 3
45˚
95
0˚
f
6x6
19
4
4x90˚
(2
87
Øu
Øb
Øa
c
c
5
4,
r
192
)
e
d
6x6
e
5,5
0˚
Inlet nozzles for forward curved centrifugal fans
Part no.
Size
Vers.
09560-2-4013
076 / 085 (1)
1
92.0
63.4
09563-2-4013
097 (1)
1
116.0
80.0
09566-2-4013
108
1
129.0
87.0
118.0
09569-2-4013
120
1
142.0
100.0
09572-2-4013
133
1
150.0
112.0
09576-2-4013
140 / 146
1
170.0
(2)
a
b
c
d
e
f
r
u
84.0
6.0
3x4.2
0.80
6.8
—
108.0
10.0
3x4.5
0.80
10.0
—
13.0
4x4.5
1.00
8.0
—
132.0
9.0
4x4.5
1.00
8.0
—
142.0
12.0
4x4.5
1.00
10.0
—
125.5
158.0
14.0
4x4.5
1.25
10.0
—
09588-2-4013
160
1
185.0
130.0
175.0
17.0
4x4.5
0.75
12.0
—
09597-2-4013
180
3
210.0
149.0
—
28.0
—
1.25
25.0
—
09605-2-4013
200 / 225
2
230.0
175.0
213.0
24.0
6x5.5
1.25
20.0
203.0
25010-2-4013
250
(3)
1
300.0
193.0
285.0
51.5
6x7
1.50
27.3
—
28010-2-4013
280 (3)
1
336.0
228.0
315.0
58.5
6x7
1.50
36.5
296.0
31010-2-4013
310 (3)
1
374.0
257.0
350.0
62.5
6x9
1.50
39.5
327.0
35510-2-4013
355
(3)
1
413.0
289.0
390.0
71.5
6x9
1.50
43.5
372.0
40010-2-4013
400 (3)
1
456.0
325.0
430.0
79.5
6x9
1.50
45.5
414.0
45010-2-4013
450 (3)
1
530.0
365.0
510.0
91.5
6x9
1.50
49.5
459.0
subject to alterations
552
(1) 3 drilled holes staggered by 120°
(2) only for 09588-2-1013
(3) 6 drilled holes staggered by 60°
General
information
Guard grille
Vers. 2
4x
90
AC centrifugal,
backward
– Material: Steel wire, plastic coated,
silver-metallic gloss
˚
a
Ød
20˚
3x1
Ød
AC centrifugal,
forward
a
e
e
b
b
Size
Vers.
a
b
d
e
78130-2-4039
310
1
280.0
4.5
230.0
2.8
78132-2-4039
400
1
345.0
4.5
310.0
2.8
78136-2-4039
450
2
425.0
8.5
350.0
3.8
78139-2-4039
500
2
445.0
8.5
410.0
3.8
78137-2-4039
560
2
490.0
8.5
430.0
3.8
78138-2-4039
630
2
600.0
8.5
490.0
3.8
EC centrifugal, backward for clean rooms
Part no.
EC centrifugal,
backward
Guard grille for backward curved centrifugal fans (according to EN 294)
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
subject to alterations
553
Contacts
Vers. 1
Guard grille
– Material: Welded grille made of galvanised
steel, frame made of tinned sheet iron
0.4 mm thick
a
11
4,5
c
Ø100
b
(4)
Size 160
Guard grilles for centrifugal blowers with single inlet
Part no.
Size
09489-2-4039
076 / 085 (3)
90.0
74.0
84.0
09490-2-4039
108
126.0
110.0
118.0
09494-2-4039
120
140.0
124.0
132.0
09492-2-4039
140 / 146
168.0
152.0
158.0
09503-2-4039
160 (4)
183.0
170.0
175.0
09493-2-4039
180 (5)
205.0
189.0
194.0
subject to alterations
a
b
(3) 3 drilled holes staggered by 120°
c
(5) not suitable for G2E180-EH03-01
– Material: Steel wire
a
c
max. e
2
d
b
Guard grilles for centrifugal blowers with single inlet
Part no.
Size
a
b
c
d
e
Coating
09603-2-4039
98214-2-4039
076 / 085
101.0
6.0
79.0
4.3
8.0
plastic coated, silver-metallic gloss
108
120.0
3.5
88.0
4.3
8.0
plastic coated, silver-metallic gloss
25028-2-4039
140 / 146
162.0
8.5
139.0
4.3
8.0
galvanised, chromatised in blue
17729-2-4039
160
175.0
3.5
139.0
4.6
7.0
galvanised, chromatised in blue
09526-2-4039
180 (6)
194.0
39.5
164.0
4.3
8.0
phosphated, plastic coated in RAL no. 9005
subject to alterations
554
(6) only suitable for G2E180-EH03-01
General
information
Guard grille
AC centrifugal,
forward
3x1
20˚
max. 8
a
AC centrifugal,
backward
– Material: Steel wire
b
2
4,3
c
a
b
c
83319-2-4039
097 (1)
96.0
3.5
71.0
phosphated, plastic coated in RAL no. 9005
09485-2-4039
097 (2)
114.0
3.5
88.0
phosphated, plastic coated in RAL no. 9005
09500-2-4039
133 / 146
145.0
4.0
122.0
phosphated, plastic coated in RAL no. 9005
31003-2-4039
180
192.0
9.5
174.0
phosphated, plastic coated in RAL no. 9005
95644-2-4039
200
250.0
5.0
206.0
plastic coated, silver-metallic gloss
(1) for D2E097-CH
(2) for D2E097-B*
– Material: Phosphated steel wire,
plastic coated, silver-metallic gloss
b
EC-SYSTEMS
3x1
2
0˚
max. 8
a
subject to alterations
Coating
EC centrifugal, backward for clean rooms
Size
EC centrifugal,
forward
Part no.
EC centrifugal,
backward
Guard grilles for centrifugal blowers with dual inlet
d
e
c
35000-2-4039
160
62226-2-4039
180
62227-2-4039
a
b
c
d
e
182.0
12.0
144.0
2.4
4.5
192.0
9.0
173.0
3.0
5.2
200
213.0
9.0
190.0
3.0
5.2
62228-2-4039
225 / 240
242.0
9.0
222.0
3.0
5.2
25825-2-4039
250
275.0
9.0
255.0
3.0
5.2
Technology
Size
subject to alterations
555
Contacts
Part no.
Accessories
Guard grilles for centrifugal blowers with dual inlet (versions with EW motor)
Guard grille
133
– Material: PA plastic 6.6 GV25 V0, black
– Special feature: Triangular, raised contour
– Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D4E146-LV
13
31
Guard grilles for blowers with dual inlet with plastic housing (cable exit side of blower)
Part no.
34265-2-2929
subject to alterations
133
– Material: PA plastic 6.6 GV25 V0, black
– Special feature: Outer two rings are closed
– Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D4E146-LV; K4E146-AB
13
31
Guard grilles for blowers with dual inlet with plastic housing (side of blower opposite cable exit)
Part no.
38182-2-2929
subject to alterations
556
General
information
Guard grille
a
AC centrifugal,
backward
– Material: Phosphated steel wire,
plastic coated in RAL no. 9005, black
0˚
6x6
c
AC centrifugal,
forward
b
max. 8
a
b
c
09513-2-4039
200
250.0
227.0
6.0
09518-2-4039
250
295.0
265.0
7.0
09532-2-4039
300
380.0
323.0
9.0
EC centrifugal, backward for clean rooms
Size
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
subject to alterations
557
Contacts
Part no.
EC centrifugal,
backward
Guard grilles (e.g. for axial fans)
Connection leads
AMP Universal Mate-N-Lok, suitable for:
Connector shell AMP 926 682-3
Plug pin AMP 926 886-1
Jacketed cable, internal leads
H03VV-F6G0.5 black
Brass lead tips
6
85
– Suitable for:
D2E140-HR; D2E146-KA; D2E146-KB;
D2E146-HR; D2E146-HS; D2E146-HT;
D2E160-FI; D2E160-FK
– Plug assignment:
1 = Step 1 (white)
2 = Step 2 (red)
3 = Step 3 (grey)
4 = Step 4 (black)
5= N
(blue)
6 = PE
(green/yellow)
a
Lead connections for centrifugal blowers
Part no.
a
21956-4-1040
300.0
21957-4-1040
450.0
21958-4-1040
650.0
21959-4-1040
1000.0
subject to alterations
AMP Universal Mate-N-Lok suitable for:
Connector shell AMP 927 231-3
Plug pin AMP 926 886-1
Jacketed cable, internal leads
H03VV-F6G0.5 black
Brass lead tips
6
85
a
Lead connections for centrifugal blowers
Part no.
a
21810-4-1012
450.0
21811-4-1012
1050.0
21812-4-1012
1300.0
21813-4-1012
1600.0
21814-4-1012
2300.0
subject to alterations
558
– Suitable for:
D4E146-LV; K4E146-AB
– Plug assignment:
1 = Step 1 (white)
2 = Step 2 (red)
3 = Step 3 (grey)
4 = Step 4 (orange)
5 = Step 5 (black)
8 = N
(blue)
9 = PE
(green/ yellow)
General
information
Connection leads
AMP Mate-N-Lok female connector
AC centrifugal,
backward
– Plug assignment:
1 = N
(black 2)
2 = L
(black 1)
3 = PE
(green / yellow)
AC centrifugal,
forward
Core-end sleeves
8
85
800
EC centrifugal,
backward
Line lead for EC centrifugal fans (clean room technology)
Part no.
22243-4-1029
Core-end sleeves
– Plug assignment:
1 = RSB
(white)
2 = RSA
(yellow)
3 = +15 V (red)
4 = 0V
(blue)
EC centrifugal,
forward
Molex Mini-Fit female connector
EC centrifugal, backward for clean rooms
subject to alterations
8
85
EC-SYSTEMS
800
Control line for EC centrifugal fans (clean room technology)
Part no.
22242-4-1029
559
Contacts
Technology
Accessories
subject to alterations
Capacitors
b
c ±10
7 ±1
Øa
M8
10
MKP motor capacitors (without fuse)
Part no.
Capacity
a
b (max.)
c
02100-4-7320
1.0 µF
25-28
58.0
235.0
99282-4-7320
1.5 µF
25-28
58.0
235.0
99283-4-7320
2.0 µF
25-28
58.0
235.0
02103-4-7320
2.5 µF
25-28
70.0
235.0
68462-4-7320
3.0 µF
25-28
70.0
235.0
99284-4-7320
4.0 µF
28-32
58.0
235.0
02101-4-7320
5.0 µF
30-36
70.0
235.0
99285-4-7320
6.0 µF
30-36
70.0
235.0
66788-4-7320
7.0 µF
30-36
72.0
100.0
99286-4-7320
8.0 µF
35-40
72.0
235.0
99287-4-7320
10.0 µF
35-40
72.0
200.0
66786-4-7320
12.0 µF
40.0
72.0
100.0
30457-4-7320
14.0 µF
40-45
92.0
150.0
50090-4-7320
16.0 µF
35-40
95.0
100.0
90034-4-7320
20.0 µF
40.0
95.0
235.0
90025-4-7320
25.0 µF
40.0
120.0
235.0
subject to alterations
560
– Material: Housing made of Thermoplast
– Connection lead: Multi-lead PVC cable
0.5 mm2 with brass lead tips
– Approval: VDE according to DIN EN 60252
(VDE 0560/8)
– Calculated life time:
400 V; -25 to +85°C; 30,000 hrs; class A
450 V; -25 to +85°C; 10,000 hrs; class B
General
information
– Material: Plastic cap, aluminium cup
– Designation: FPU or P2 according to
IEC 252 (non-flammable, non-explosive,
circuit-breaking)
– Approval: VDE according to DIN EN 60252
(VDE 0560/8)
– Calculated life time:
420 V; -25 to +85°C; 30,000 hrs; class A
470 V; -25 to +85°C; 10,000 hrs; class B
500 V; -25 to +85°C; 3,000 hrs; class C
Øa
M8
Ø a + 3,5
b
7 ±1
35 +5
235 +10
-5
a
b (max.) c (max.)
02151-4-7320
1.0 µF
25-30
77.0
92.0
02155-4-7320
1.5 µF
25.0
77.0
92.0
02156-4-7320
2.0 µF
25.0
77.0
92.0
02159-4-7320
2.5 µF
30.0
71.0
92.0
02160-4-7320
3.0 µF
30.0
71.0
92.0
02161-4-7320
4.0 µF
25-30
104.0
135.0
02162-4-7320
5.0 µF
25-30
104.0
113.0
02163-4-7320
6.0 µF
30.0
101.0
110.0
02164-4-7320
7.0 µF
30-35
101.0
110.0
02165-4-7320
8.0 µF
30-35
102.0
111.0
02166-4-7320
10.0 µF
35.0
96.0
110.0
02167-4-7320
12.0 µF
35.0
96.0
110.0
90026-4-7320
14.0 µF
40.0
130.0
139.0
02168-4-7320
16.0 µF
40.0
96.0
130.0
02169-4-7320
20.0 µF
40.0
116.0
130.0
02170-4-7320
25.0 µF
40-45
116.0
130.0
EC centrifugal, backward for clean rooms
Capacity
EC centrifugal,
forward
Part no.
EC centrifugal,
backward
MKP motor capacitors FPU or P2 (with fuse)
AC centrifugal,
backward
c
10
AC centrifugal,
forward
Capacitors
EC-SYSTEMS
Accessories
Technology
– Pull-off protector: The housing expands by
max. 9 mm. The protector responds to overload by the generated excess pressure snapping off the internal lead in a predetermined
breaking point.
– Mounting: c is the overall dimension of the
capacitor which has to be taken into account
when mounting the part. The capacitor
design, however, depends on the manufacturer. The expansion (9 mm) is either added
to dimension b, or it is already integrated in
the capacitor.
561
Contacts
max. 9 mm
subject to alterations
Terminal box
=
91,5
b
58
12
29
94
Øa
c
56
=
3
18
27,5
Terminal box
Part no.
AC motor
a
b
c
64442-1-7612
64444-1-7612
068 (4 poles)
22.0
5.0
4.3
068 (7 poles)
22.0
5.0
4.3
64443-1-7612
074 (4 poles)
12x14.5
10.5
5.5
64445-1-7612
074 (7 poles)
12x14.5
10.5
5.5
subject to alterations
562
– Material: ABS
– Description: Two-piece terminal box for AC
motors of size 068 or 074, terminal strip
with 4- or 7-pole. Suitable for installation of
capacitor with 10 µF max.
– Type of protection: IP 54
General
information
Air filter
c
b
AC centrifugal,
backward
– Material: Steel wire / sheet steel,
plastic coated in RAL no. 9005, black
– Filter: Viledon filter type R: PSB / 29 OS
(according to DIN 24185)
Separation capacity: < 86 %
Efficiency: < 20 %
Dust binding capacity: 650 g/m2
e
AC centrifugal,
forward
d
a
95777-1-5171
108 / 120
95778-1-5171
140 / 146 / 160
95347-1-5171
180
a
b
c
d
142.0
66.0
83.0
118-132 145.0
95779-1-5171
185.0
74.0
91.0
158-175 185.0
95780-1-5171
210.0
74.0
91.0
194.0
e
185.0
Spare filter
95780-1-5171
EC centrifugal, backward for clean rooms
Size
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
subject to alterations
563
Contacts
Part no.
EC centrifugal,
backward
Air filters for centrifugal blowers (with die-cast aluminium housing)
Speed setting, 3-phase (with 5 steps)
for wall assembly
Current draw
Mass
Type
Frequency
Nominal data
Nominal voltage
– Technical features: Input for TOP
– Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC
– Type of protection: IP 20 (with vertical installation)
VAC
Hz
A
kg
TCD 020-AA01 -05
3~
400
50/60
2.0
9.5
TCD 040-AA01 -05
3~
400
50/60
4.0
13.9
TCD 070-AA01 -05
3~
400
50/60
7.0
19.7
subject to alterations
166
189
4xØ5,5
185
266
189
224
309
304
564
General
information
Speed setting, single-phase (with 5 steps)
for wall assembly
Hz
A
kg
TCE 021-AA01 -05
1~
230
50/60
2.1
3.6
TCE 040-AA01 -05
1~
230
50/60
4.0
4.8
TCE 075-AA01 -05
1~
230
50/60
7.5
6.5
EC centrifugal,
backward
Mass
VAC
EC centrifugal, backward for clean rooms
Current draw
Type
Frequency
Nominal data
Nominal voltage
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features: Input for TOP
– Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC
– Type of protection: IP 40
subject to alterations
EC-SYSTEMS
Accessories
147
167
86
4xØ7
EC centrifugal,
forward
144
200
565
Contacts
Technology
154
204
Motor protection switch, 3-phase
for assembly inside a cabinet
Current draw
Mass
Type
Frequency
Nominal data
Nominal voltage
– Technical features: Input for TOP
VAC
Hz
A
kg
Auxiliary contactor
TPD 250-AB01 -01
3~
400
50/60
25.0
0.3
without auxiliary contactor
TPD 250-AB01 -02
3~
400
50/60
25.0
0.3
with break contact
TPD 250-AB01 -03
3~
400
50/60
25.0
0.3
with make contact
subject to alterations
68
– Electr. connection:
7
566
54,5
66,5
General
information
Motor protection switch, single-phase
for assembly inside a cabinet
Current draw
Mass
VAC
Hz
A
kg
Auxiliary contactor
TPE 100-AB01 -01
3~
230
50/60
10.0
0.3
without auxiliary contactor
TPE 100-AB01 -02
3~
230
50/60
10.0
0.3
with break contact
TPE 100-AB01 -03
3~
230
50/60
10.0
0.3
with make contact
EC centrifugal, backward for clean rooms
Frequency
Type
Nominal voltage
Nominal data
EC centrifugal,
backward
AC centrifugal,
forward
AC centrifugal,
backward
– Technical features: Input for TOP
subject to alterations
52,5
EC-SYSTEMS
45
Technology
Accessories
70
78
567
Contacts
103
46
EC centrifugal,
forward
– Electr. connection:
Motor-protection switch, single phase and three-phase
for wall assembly
Current draw
Mass
Type
Frequency
Nominal data
Nominal voltage
– Technical features: Input for TOP
– Type of protection: IP 55
VAC
Hz
A
kg
Auxiliary contactor
TPD 250-AA01 -01
3~
400
50/60
25.0
0.6
without auxiliary contactor
TPD 250-AA01 -02
3~
400
50/60
25.0
0.6
with break contact
TPD 250-AA01 -03
3~
400
50/60
25.0
0.6
with make contact
TPE 100-AA01 -01
1~
230
50/60
10.0
0.6
without auxiliary contactor
TPE 100-AA01 -02
1~
230
50/60
10.0
0.6
with break contact
TPE 100-AA01 -03
1~
230
50/60
10.0
0.6
with make contact
subject to alterations
92
80
141
79
38
568
– Electr. connection, three-phase:
– Electr. connection, single-phase:
20
General
information
Star-delta switch / repair switch
Third-party accessories from Möller Electric GmbH
AC centrifugal,
forward
AC centrifugal,
backward
More information: www.moeller.net
for wall installation
Designation
Installation
T0-4-8410/I1
Wall installation
T0-4-8410/E
Cabinet installation
EC centrifugal,
backward
Star-delta switch (available from Möller Electric GmbH)
EC centrifugal, backward for clean rooms
subject to alterations
EC centrifugal,
forward
More information: www.moeller.net
EC-SYSTEMS
for wall installation
Repair switch, lockable (available from Möller Electric GmbH)
Designation
Installation
T0-2-8900/I1/SVB-SW
Wall installation
T0-2-8900/EA/SVB-SW
Cabinet installation
569
Contacts
Technology
Accessories
subject to alterations
570
Technology
Accessories
EC-SYSTEMS
EC centrifugal,
forward
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Impellers
576
Motors
590
Control technology
594
571
AC centrifugal,
backward
572
AC centrifugal,
forward
Technical parameters & scope
Contacts
General
information
Technology
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
General performance parameters
Service life
Any deviations from the technical data and parameters described here
The service life of ebm-papst products depends on two major factors:
are listed on the product-specific data sheet.
– The service life of the insulation system
– The service life of the bearing system
Type of protection
The service life of the insulation system mainly depends on voltage level,
The type of protection is specified in the product-specific data sheets.
temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
Insulation class
on the bearing.
The insulation class is specified in the product-specific data sheets.
The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
Mounting position
used, which is indicated on the product-specific data sheet wherever
The mounting position is specified in the product-specific data sheets.
applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
Condensate discharge holes
operating hours at an ambient temperature of 40 °C, yet this estimate
Information on the condensate discharge holes is provided in the
can vary according to the actual ambient conditions.
product-specific data sheets.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
Protection class
product-specific data sheets.
The protection class is specified in the product-specific data sheets.
Depending on motor type and field of application, the following protective
features are realised:
– Thermal overload protection (TOP), either in-circuit or external
– PTC with electronic diagnostics
– Impedance protection
– Thermal overload protection (TOP) with electronic diagnostics
– Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
All fans with 1~ AC voltage are equipped with a TOP that is connected
in the winding circuit.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.
572
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Legal and normative directives
All ebm-papst products are subjected to comprehensive tests complying
The products described in this catalogue are designed, developed and
with the normative specifications. In addition to this, the tests also reflect
produced in keeping with the standards in place for the relevant product
the vast experience and expertise of ebm-papst.
and, if known, the conditions governing the relevant fields of application.
Vibration test
Standards
Vibration tests are carried out in compliance with
Information on standards is provided in the product-specific data sheets.
– Vibration test in operation according to DIN IEC 68, parts 2-4
EMC
Shock load tests are carried out in compliance with
Complying with the EMC standards has to be established on the final
– Shock load according to DIN IEC 68, parts 2-27
appliance, as different mounting situations can result in changed EMC
properties.
Testing the balancing quality is carried out in compliance with
Leakage current
– Residual imbalance according to DIN ISO 1940
Information on the leakage current is provided in the product-specific
– Standard balancing quality level G 6.3
data sheets.
Should you require a higher balancing quality level for your specific
The measurement takes place according to Fig. D.1 according to
application, please let us know and specify this when ordering your
IEC 60990, Fig. 4.
EC-SYSTEMS
Balancing quality
product.
In case you require a specific approval for your ebm-papst product
Should you have questions about chemo-physical strain, please direct
(VDE, UL, GOST, CCC, CSA, etc.) please let us know.
them to your ebm-papst contact.
Most of our products can be supplied with the relevant approval.
Accessories
Approvals
Chemo-physical strain / performance parameters
Information on existing approvals is provided in the product-specific
Fields of application, industries and applications
data sheets.
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room
Air performance measurements
technology, automotive and rail technology, medical and laboratory tech-
All air performance measurements are carried out on inlet-side chamber
nology, electronics, computer and office technology, telecommunications,
test rigs in conformity with the requirements of DIN 24163 and ISO 5801.
household appliances, heating, machines and plants, drive engineering.
The fans being tested are installed on the measuring chamber at free air
Our products are not designed for use in the aviation and aerospace
intake and discharge (installation type A according to DIN 24163 Part 1)
industry!
and are operated at nominal voltage (for AC, also at nominal frequency)
Technology
sheets.
EC centrifugal,
forward
Information on EMC standards is provided in the product-specific data
Shock load
without additional attachments such as the guard grille.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
573
Contacts
– Vibration test at standstill according to DIN IEC 68, parts 2-4
EC centrifugal,
backward
Mechanical strain / performance parameters
EC centrifugal, backward for clean rooms
Left: Endurance test room
Middle: Shock test
Right: Chamber test rig
Room for precision noise measuring
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
– Axial and centrifugal fans with direction of air flow "V", without guard
grille and in the wall ring
– Backward curved centrifugal fans, free-running and with inlet nozzle
– Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All noise levels are measured in conformity to DIN 45635 and
ISO 3744/3745 according to precision class 2 and specified A-weighted.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (Lw), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
D
from the sound pressure level by adding 7 dB.
1,5d
(see graphic). The sound level measured can be roughly calculated
Measurement configuration according to DIN 45635 T38:
10 measuring points
d≥D
h
Measurement area S = 6d2 + 7d (h + 1.5d)
3d
h = 1.5d to 4.5d
2d
574
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
15
Adding multiple noise sources with the same level
[dB]
Curves
The level increase measured from the diagram is 9 dB. Thus the overall
sound level of the installation can be expected to be 84 dB(A).
10
EC centrifugal, backward for clean rooms
sheet, the sound pressure level of a fan is approximately 75 dB(A).
1
2
5
8
10
15
20 25
EC centrifugal,
forward
Example: 8 A3G800 axial fans are on a condenser. According to the data
9
sheet. This is shown in the diagram opposite.
5
be determined in advance based on the noise values specified in the data
0
of approx. 3 dB. The noise characteristics of multiple identical fans can
Increase in sound pressure / sound power level
Adding 2 noise sources with the same volume results in a level increase
3
Adding two noise sources with different levels
[dB]
Number of sources of sound with identical level
be read in the diagram as approx. 1.5 dB. This means that the overall
sound level of the unit can be expected to be 76.5 dB(A).
2
EC-SYSTEMS
a ventilation unit. The level difference is 4 dB. The level increase can now
0
4
8
12
16
20
24
[dB]
0
Inverse square laws
[dB]
Difference in level with two sources of sound
Accessories
75 dB(A) at the operating point and an axial fan A3G710 with 71 dB(A) in
1,5
Example: There is an axial fan A3G800 with a sound pressure level of
1
diagram opposite.
0
based on the sound levels given in the data sheet. This is shown in the
Increase in sound pressure / sound power level
The acoustic performance of two different fans can be predetermined
The sound level is independent of the distance from the noise source.
-10
Conversely, the sound pressure level decreases as distance from the
noise source increases. The diagram to the right shows the level decrease
reduction of 26 dB for the 20 m distance.
-20
-26
Technology
a distance of 20 m. In the diagram to the right, you can now read a
1
Distance
2
5
10
20
50
100
[m]
575
Contacts
the operating point. Now, you want to measure the noise characteristics at
-30
Example: An axial fan A3G800 has a sound pressure level of 75 db(A) at
-40
the noise source under far-field conditions.
Decrease in sound pressure level
expressed in terms of an output measurement at a distance of 1 m from
Impellers
Impellers made by ebm-papst
Like pumps and compressors, fans and blowers belong to the category of aerodynamic and fluid work machines.
A fan consists of an impeller, a drive motor and a housing for suspension and for guiding the air flow. The blades spaced
along the circumference of the impeller are designed in such a way as to cause the flowing work medium to change
direction, thus passing on pressure and speed energy.
ebm-papst construction designs
Application-specific selection parameters
Depending on the geometrical shape of the impeller, there are different
When selecting an application-specific fan or blower, the main parameters
construction designs, with their names taken from the main flow
to be taken into account are these:
direction in the impeller.
– Air flow at given back pressure
– Constructional design
The most important designs are:
– Speed/rpm
– Axial fans
– Impeller diameter
– Centrifugal fans with backward curved blades
– Ambient conditions governing suction and exhaust side
– Single or dual inlet centrifugal blowers with forward curved blades
– Diagonal (mixed flow) fans (a cross between axial and centrifugal fans)
Relevant fields of application of the various construction designs
The different ebm-papst fan and blower designs correspond to the
different fields of application:
– Small back pressures: axial fans
– High back pressures: centrifugal fans with backward curved blades
and single or dual inlet centrifugal blowers
– Threshold between axial and centrifugal fans: diagonal fans
[Pa]
Characteristic curves of the various designs
axial fans
centrifugal fans, backward curved
centrifugal blowers, single inlet
centrifugal blowers, dual inlet
diagonal fans
1200
1000
800
600
400
200
200
576
500
1000
2000
5000
10000
20000
50000
[m³/h]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Axial fans
Operating range
EC centrifugal,
backward
Noise / efficiency curve
[%]
[Pa]
– Maximum efficiency
– Minimal noise
[dB(A)]
To the right of the "saddle" (right part of the air performance curve):
To the left of the "saddle" (left part of the air performance curve):
EC centrifugal, backward for clean rooms
– Stall area
– Drop in efficiency
– Soaring noise
The optimum operating range of the fan is shaded in green in the
curve given here.
optimum operating range
EC centrifugal,
forward
0
stall area
0
[m³/h]
Direction of air flow
EC-SYSTEMS
The direction of air flow is given as follows:
Accessories
Direction of air flow "V" Direction of air flow "A"
Technology
"A" 577
Contacts
"V"
Effects when mounted in wall ring or in the aperture
Curve
[Pa]
performance in the operating range.
[%]
Mounting the fan in a wall ring can significantly increase the air
1
1
Wall ring
2
Aperture
2
1
0
2
0
[m³/h]
Effects with axial position in the wall ring
Curve
[Pa]
[%]
Axial position in the wall ring influences air performance and efficiency.
1
Projecting on
inlet side
x/D=7%
2
Flush on inlet side
x/D=0%
3
2
Immersed on
inlet side
x / D = -7 %
1
x
x
3
x
D
D
D
1
2
0
3
0
[m³/h]
578
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Effects with guard grilles
EC centrifugal,
backward
Curve
[Pa]
[%]
Mounting a guard grille reduces the air performance of the axial fan.
With guard grille
1
2
1
EC centrifugal,
forward
0
2
EC centrifugal, backward for clean rooms
Without guard grille
2
0
[m³/h]
V in [m3/h]
For the guard grilles used at ebm-papst, the correction factor GG can be
used depending on the impeller diameter D from the table to the right.
Correction factor GG
130
10000
143
6600
180
2550
200
1650
250
650
300
300
315
240
350
150
400
90
450
55
500
35
560
20
630
11
710
6
800
3
910
1.5
990
0.9
EC-SYSTEMS
∆pGG = GG . 10-8 . V2
Diameter D
Accessories
following equation:
Technology
The pressure drop in Pa can be roughly calculated according to the
579
Contacts
1
Effects of obstructions on the suction or exhaust side
Curve
Disturbances or obstructions on the suction or pressure side reduce
[Pa]
the air performance of the axial fan.
1
Obstructions on the inlet side
1
x/D= 2
x / D = 35 %
3
x / D = 18 %
4
x/D=
9%
5
x/D=
5%
D
X
2
3
4
0
5
0
[m³/h]
1
x/D= 2
x / D = 35 %
3
x / D = 18 %
4
x/D=
9%
5
x/D=
5%
X
D
[Pa]
Obstructions on the exhaust side
2
4
3
1
0
5
0
[m³/h]
580
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Centrifugal fans with backward curved blades
Operating range
EC centrifugal,
backward
Noise / efficiency curve
[%]
[Pa]
– Maximum efficiency
– Minimal noise
[dB(A)]
Middle part of air performance curve:
To the right and the left of the middle part of the air performance curve:
EC centrifugal, backward for clean rooms
– Reduced efficiency
– Increasing noise
The optimum operating range of the fan is shaded in green in the curve
given here.
EC centrifugal,
forward
0
optimum operating range
0
[m³/h]
Effects of nozzle gap dimension
Curve
s / D = 0.4 %
2
s / D = 1.0 %
3
s / D = 1.4 %
[%]
[Pa]
3
2
1
3
2
1
Accessories
1
0
D
S
influences the air performance and efficiency of the centrifugal fan.
EC-SYSTEMS
The centrifugal air gap between the inlet nozzle and impeller cover plate
0
581
Contacts
Technology
[m³/h]
Effects of overlapping dimension
Curve
[%]
influences the air performance and efficiency of a centrifugal fan.
[Pa]
The axial overlap between the inlet nozzle and impeller cover plate
1
2
X
1
x / D = 0.6 %
2
x/D= 0 %
3
x / D = -0.8 %
3
1
2
0
D
3
0
[m³/h]
Effects of installation space
Curve
When mounting our product in a rectangular box, air performance
0,99
1,00
might be reduced.
0,95
0,94
0,93
0,92
Correction factor for air flow
D
D
0,5xD
H
0,96
0,97
0,98
B
1,4
1,6
1,8
Hydraulic diameter dh/D
dh = Hydraulic diameter
Formula: dh = 2 x B x H / (B + H)
B = Width of box
H = Height of box
D = Outer diameter of the fan
582
2,0
2,2
2,4
2,6
2,8
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
Air flow measurement for inlet nozzles with
pressure-measuring point
The differential pressure approach compares the static pressure before
EC centrifugal, backward for clean rooms
the inlet nozzle with the static pressure inside the inlet nozzle.
EC centrifugal,
forward
D
0,5xD
Air flow can be calculated on the basis of the differential pressure
(difference in pressure of the static pressures) in keeping with the
W
V in [m3/h] and ∆pW in [Pa]
EC-SYSTEMS
following equation:
V = k . ∆p
If constant air flow control is used, then the nozzle pressure has to be
kept constant:
∆pW = V2 : k2
k takes into account the specific nozzle characteristics.
One or four pressure measuring points are spaced along the
Accessories
circumference of the inlet nozzle. Connection on the customer side
is accomplished via a premounted T tube connector. This tube connector
583
Contacts
Technology
is suited for pneumatic hoses with an internal diameter of 4 mm.
Single and dual inlet centrifugal blowers
with forward curved blades
The forward curved centrifugal impeller must always be operated inside
a scroll housing.
A dual inlet centrifugal blower shows the same behaviour as two single
inlet blowers operated in parallel: with size, speed and pressure being
identical, double the air flow is achieved.
Operating range
Noise / efficiency curve
[%]
[Pa]
– Maximum efficiency
– Minimal noise
– higher performance density than with the backward curved
centrifugal fan
To the right and the left of the middle part of the air performance curve:
– Reduced efficiency
– Increasing noise
The optimum operating range of the fan is shaded in green in the
curve given here.
0
optimum operating range
0
[m³/h]
Dimensioning of the scroll
The dimensions of a typical scroll can be calculated with the following
formulae, subject to the impeller diameter D:
A = 1.062 · D
J
B = 0.992 · D
B
A
K
C = 0.922 · D
45˚
45˚
H
26˚
C
45˚
45˚
45˚
45˚
F
D
E
G
R
D = 0.853 · D
E = 0.784 · D
F = 0.715 · D
G = 0.646 · D
H = 0.612 · D
J = 0.720 · D
K = 0.689 · D
R = 0.073 · D
Adjusting the dimensions to diminished mounting spaces is possible.
584
[dB(A)]
Middle part of air performance curve:
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Effects of step diffusers
EC centrifugal,
backward
Curve
without step diffuser
2
with step diffuser
1
2
EC centrifugal, backward for clean rooms
1
[Pa]
increases air performance and efficiency of the centrifugal blower.
[%]
A diffuser mounted on the exhaust side with connected exhaust tunnel
1
EC centrifugal,
forward
0
2
0
[m³/h]
Effects of obstructions on the intake side
Curve
x / D = 30 %
3
x / D = 23 %
4
x / D = 15 %
5
x / D = 7.5 %
Accessories
x/D= 2
X
5
4
3
2
1
0
0
[m³/h]
Technology
X
1
585
Contacts
D
[Pa]
centrifugal blower.
EC-SYSTEMS
Obstructions on the air intake side reduce the air performance of the
Effects caused by obstructions on the inlet side for constant air flow
EC centrifugal blowers
Constant air flow is attained with unimpaired inflow only.
An obstructed (e. g. asymmetrical or partially blocked) air flow can have a
significant effect on the curve behaviour and cause large deviations from
a constant air flow curve.
Examples of obstructed inflows
X
Instructions for designing a sufficiently unobstructed inflow:
– The distance x between the blower intake and neighbouring walls or
obstructions should be at least 25 % of the impeller diameter.
– Inflows with angular momentum or asymmetrical rotation should be
avoided.
– The inflow can be made more uniform using resistances such as those
from filters or grilles.
On request, we offer calibrated blower designs that incorporate a specific
installation situation.
586
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Diagonal fans (axial design)
Noise / efficiency curve
EC centrifugal,
backward
Operating range
[%]
[Pa]
performance curve):
– Maximum efficiency
[dB(A)]
Directly to the right of the "saddle" (right part of the air
– Minimal noise
EC centrifugal, backward for clean rooms
To the left of the "saddle" (left part of the air performance curve):
– Stall area
– Drop in efficiency
– Soaring noise
The saddle of the diagonal / mixed flow fan is slightly higher than that
of the axial fan. This means that the technical ratings in the optimal
optimum operating range
EC centrifugal,
forward
The optimum operating range of the fan is shaded in green in the
stall area
0
operating range are better than those of the axial fan.
0
[m³/h]
curve given here.
Mounting information
EC-SYSTEMS
The conical housing (part of delivery) makes sure the necessary gap
dimension is kept.
Effects
The effects of the diagonal / mixed flow fan are similar to those listed
587
Contacts
Technology
Accessories
for the axial fan (p. 577-580).
Dimensioning / change in speed
A change in speed influences:
140
– Air flow V
120
[%]
Influence of speed n
160
Curve
V~n
1.4n
1.3n
100
1.2n
n
80
– Static pressure increase pfa
1.1n
∆pfa ~ n2
0.9n
60
– Requirement of energy P1
0.8n
0.7n
40
P1 ~ n3
0
20
0.6n
0
20
40
60
80
100
120
140
[%]
Influence of the speed n on the sound level Lw
[dB]
Curve
20
When the speed changes, the approximate sound level can be
determined using the diagram to the right and the following formula:
Lw - Lw = 50 dB . log (n : n )
n1 = Changed speed
n2 = Starting speed
0
Lw1 = Sound level after speed change
Lw2 = Sound level before speed change
10
1
-10
2
-20
1
modification in sound pressure level
2
0,5
1
factor of speed change
588
1,5
2
2,5
3
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
1.2D
120
– Air flow V
1.1D
100
D3
– Static pressure increase ∆pfa
D
80
∆pfa ~ D2
EC centrifugal, backward for clean rooms
A change in impeller diameter influences:
V~
160
1.3D
140
Influence of impeller diameter D
[%]
Curve
0.9D
60
– Requirement of energy P1
0.8D
0.7D
40
P1 ~ D5
0
20
0.6D
20
40
60
80
100
120
140
EC centrifugal,
forward
0
[%]
V~b
140
160
EC-SYSTEMS
– Air flow V
120
A change in width of the air discharge influences, in approximation:
100
Influence of width of air discharge b (only for centrifugal impellers)
[%]
Curve
1.1b
b
Accessories
60
40
0.7b
0.9b
0.6b
0.8b
1.3b
1.2b
1.4b
20
20
40
60
80
100
120
140
[%]
Technology
0
589
Contacts
P1 ~ b
0
∆pfa = const
– Requirement of energy P1
80
– Static pressure increase ∆pfa
Motors
Motors made by ebm-papst
In AC and EC technology, ebm-papst relies on the proven external-rotor motor principle, with the rotor turning
around the stator within. Advantages of the ebm-papst external-rotor principle are:
– Space saving design due to integrated bearings and direct installation inside the impeller
– lower load and more precise balancing of the bearing due to the fixed connection of all rotating elements
– Prolonged service life due to the motor-impeller unit placed right within the air flow
The ebm-papst motors achieve very good results in efficiency and acoustic behaviour when used in EC technology.
Features
AC motors
Shaded-pole motor
Single-phase capacitor motor
1~ AC voltage
connector
Yes
Yes
3~ AC voltage
connector
No
No
DC voltage connector
No
No
EC motors
3-phase motor
Single-core motor
3-core motor
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Electronics
(see p. 598)
Electronics
(see p. 598)
Limited use
(Steinmetz circuit)
Design of circuit
diagram - Stator -
Steinmetz circuit
Rotor principle
Squirrel cage
Squirrel cage
Squirrel cage
Magnetic rotor
Magnetic rotor
Efficiency
Low
Medium
Good
Excellent
Excellent
Continuous speed
setting integrated
No
No
No
Yes
Yes
Medium
Good
Excellent
Medium
Excellent
Noise behaviour
590
General
information
AC centrifugal,
backward
AC centrifugal,
forward
AC motors (induction motors) are based in their function on the principle
Shaded-pole motor
of the asynchronous rotation of the stator rotating field and rotor.
Each pole of the motor is divided electro-magnetically into a main
EC centrifugal,
backward
AC motors
and auxiliary pole (split) via a cage winding in order to generate a
Torque curves of the motor types
starting torque.
symmetrical external or internal rotor designs.
2
EC centrifugal, backward for clean rooms
[Ncm]
At ebm-papst, shaded-pole motors are available as 2 or 4-pole
1
3
MK
4
EC centrifugal,
forward
M Sa
5
M St
Advantages:
– Extremely robust motor design due to cast squirrel cage rotor and
stable bearing system
– Cost-efficient motor
5 – System characteristic
MSt – Starting torque
MSa – Saddle torque
MK – Breakdown torque
– Extremely easy to connect
EC-SYSTEMS
Key:
1 – EC motor
2 – 3-phase motor
3 – Single-phase motor
4 – Shaded-pole motor
– Long service life
Start-up current
Accessories
The start-up current of our AC motors is maximally 4x higher
591
Contacts
Technology
than the nominal current given.
Single-phase capacitor motor
3-phase motor
Two cores (main winding MW and auxiliary winding AW) generate the
The three motor cores are offset by 120° and generate a circular rotating
rotating field of the single-phase capacitor motor via a capacitor
field when connected to the 3-phase mains.
connected in series to form an auxiliary winding.
c ≈ 70 µF/kW
(230 VAC ∆)
Star
Delta
Steinmetz circuit
Advantages:
Advantages:
– Extremely robust motor design due to cast squirrel cage rotor and
stable bearing system
– Extremely robust motor design due to cast squirrel cage rotor and
stable bearing system
– Very good vibration and noise behaviour
– Diverse options for setting speed
– Efficiency between 40 % and 80 % (depending on the motor size)
– Efficiency between 30 % and 75 % (depending on motor size)
– Long service life
– Long service life
– Good vibration and noise behaviour
[Ncm]
Torque curves of 3-phase motors
1
3
2
Key:
1 – Delta
2 – Star
592
3
– Steinmetz circuit
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC motors
Single-core motor
EC centrifugal,
backward
EC motors are based in their function on the principle of the
synchronous rotation of stator rotating field and rotor.
Electronics
[Ncm]
Torque curves of the motor types
EC centrifugal, backward for clean rooms
2
1
3
Advantages:
– Integrated speed setting
– Efficiency between 50 % and 80 % (depending on the motor size)
4
M St
EC centrifugal,
forward
– Long service life
M Sa
5
3-core motor
EC-SYSTEMS
Electronics
Accessories
5 – System characteristic
MSt – Starting torque
MSa – Saddle torque
MK – Breakdown torque
Advantages:
– Integrated speed setting
– Good efficiency between 60 % and 90 %
(depending on the motor size)
– Long service life
– Very good vibration and noise behaviour even in controlled operation
– Can be used as drive motor
Technology
Key:
1 – EC motor
2 – 3-phase motor
3 – Single-phase motor
4 – Shaded-pole motor
593
Contacts
MK
Control technology
Open and closed loop control using ebm-papst technology
Depending on the field of application, fan speed has to be adjusted. In AC technology, the speed setting option can
result in an increase in installation expenditure and, typically, a less favourable noise performance and an increase in
power input.
Here, ebm-papst EC technology is a more eco-friendly and cost-efficient alternative. The EC motor with integrated
commutation electronics offers high efficiency across the entire speed range and optimal acoustic performance at
minimal installation expenditure.
Speed stepping
Phase-angle control
Phase-angle control
with sine filter
Frequency inverter
Frequency inverter
with sine filter
integrated
integrated with
switch power
supply
external
EC commutating electronics
Transformer
AC
Series resistance
Features
Installation
+
–
+
–
–
–
–
++
–
–
Noise behaviour
+
++
–
––
–
–
+
++
+
+
Power input
––
–
–
–
–
+
+
++
+
+
Service life
+
+
–
–
+
–
+
+
+
+
+ = positive + + = very positive
Power input of controlled motors
[dBA]
[W]
Acoustic performance of controlled motors
– = negative – – = very negative
70
1500
60
50
1000
40
500
30
0
1000
2000
2000
4000
3000
4000
6000
5000
8000
Key:
ebm-papst EC controls
Frequency inverter with sine filter
Phase-angle control without sine filter
Phase-angle control with sine filter
Transformer
594
6000
[CFM]
10000
[m³/h]
0
1000
2000
2000
4000
3000
4000
6000
5000
8000
Key:
ebm-papst EC controls
Frequency inverter with sine filter
Phase-angle control without sine filter
Phase-angle control with sine filter
Transformer
6000
[CFM]
10000
[m³/h]
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Speed setting helps to optimise power input
When selecting a voltage controller, note that the nominal current in the
and the flow noise as requested.
partial load range can be up to 20 % (depending on the controller) above
EC centrifugal,
backward
Speed setting with AC motors
the specified maximum current.
Series resistance
AW
R1
0
– Speed setting via change in motor voltage
ASM
1~
– Cost-efficient
R2
1
2
L1
EC centrifugal, backward for clean rooms
– Fixed speed steps
C
MW
– Small capacities
3
Note: Capacitors or chokes reduce the loss capacity.
N
PE
L1
4
Tr
– Fixed speed steps
AW
3
EC centrifugal,
forward
Transformer
C
2
– Speed setting via change in motor voltage
ASM
1~
1
MW
N
EC-SYSTEMS
PE
Phase-angle control
– Continuous speed setting
C
AW
– Speed setting via change in motor voltage
ASM
1~
– Cost-efficient
– Acoustic performance and warming has to be reviewed
Accessories
in the application
N
PE
Frequency inverter with sine filter
T1 T3 T5
– Speed setting via change in frequency of rotating field
+
L3
U
U
V
V
W
T2 T4 T6
W
– High efficiency
Technology
L1
L2
– Continuous speed setting
ASM
3~
Note: An all-pole sine filter (phase-phase and phase-earth)
has to be used.
PE
595
Contacts
L1
MW
Tr
Electrical connections AC
Fans, 1 speed (3~ 230 VAC power line)
Fans (1~ 230 VAC power line)
A1) Single-phase capacitor motor
N
PE
L
C
U2 Z
U1
U1 = blue
U2 = black
Z = brown
= green/
yellow
TOP
with connection for external TOP
N
PE
C
TOP
U2 Z
U1
U1 = blue
U2 = black
Z = brown
= green/
yellow
A2b) Single-phase capacitor motor
with connection for external TOP
C
U1 Z U2
L
N PE
Fans
with terminal box
596
Shaded pole motor
C1) Delta connection (3~ 230 VAC power system)
L
PE
N
without TOP
L
N
= blue
= brown
= green/
yellow
L1
PE
L2
U1
V1
U2
V2
U1
U2
V1
V2
W1
W2
L3
W1
W2
TOP
A2a) Single-phase capacitor motor
L
B)
with TOP wired internally
with TOP wired internally
TOP TOP
U1 = blue
U2 = black
Z = brown
= green/
yellow
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
D1) Delta connection (3~ 230 VAC power line)
with TOP
L1
PE
L2
U1
V1
U2
V2
L3
W1
W2
TOP
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
Direction of rotation is reversed by swapping
two line phases.
General
information
AC centrifugal,
backward
AC centrifugal,
forward
C2) Star connection (3~ 400 VAC power system) E1) Delta connection (high speed)
U1
V1
W1
U2
V2
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
D2) Star connection (3~ 400 VAC power line)
with TOP
PE
L1
L1
PE
L2
U1
V1
U2
V2
U1
U2
V1
V2
W1
W2
L3
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
F1a) Delta connection (high speed)
U1
V1
W1
U2
V2
W2
L3
TOP
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
Direction of rotation is reversed by swapping
two line phases.
L1
PE
V1
U2
V2
L2
U1
U2
V1
V2
W1
W2
L3
U1
V1
W1
U2
V2
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
with TOP
L2
U1
L1
F2a) Star connection (low speed)
with TOP
L2
PE
EC centrifugal, backward for clean rooms
U1
U2
V1
V2
W1
W2
L3
EC centrifugal,
forward
L2
L3
TOP
W1
W2
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
F1b) Delta connection (high speed)
L2
U1
V1
W1
U2
V2
W2
L3
TOP
U1
U2
V1
V2
W1
W2
with TOP
U1 V1 W1 W2 U2 V2 TOP TOP
Fans
with terminal box
L1
F2b) Star connection (low speed)
with TOP
L1 L2 L3
PE
EC-SYSTEMS
L1
without TOP
PE
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/
yellow
U1 V1 W1 W2 U2 V2 TOP TOP
L1 L2 L3
Fans
with terminal box
PE
U1
U2
V1
V2
W1
W2
Accessories
PE
E2) Star connection (low speed)
without TOP
Technology
without TOP
EC centrifugal,
backward
Fans, 2 speeds via ∆/Y-switch (3~ 400 VAC power line)
Direction of rotation is reversed by swapping two line phases.
597
Contacts
Fans, 1 speed (3~ 400 VAC power line)
Speed setting with EC motors
The speed of EC motors is set via commutation electronics. Via electronic
circuits and depending on the rotor position, this commutation switches
the motor currents on and off.
Principle of AC-fed commutation electronics
Interface
Control unit
Principle of DC-fed commutation electronics
Power unit
Interface
Control unit
Power unit
EMC filter
0-10 VDC
0-10 VDC
PWM
PWM
DC/DC transformer
EMC filter
Commutations unit
Rectifier
Feedback
Commutations unit
Feedback
Link electrolytic capacitor
Inverter stage
CAN
LON
Drive
CAN
LON
Inverter stage
Drive
RS485
RS485
(with electrically isolated interface)
Integrated commutation electronics
– Compact unit
– Easy to install
AC
– Low installation expenditure
– Can be operated all over the world
Note: Motors with 12-72 VDC supply voltage have to be fed via
electrically isolated supply unit.
DC
Integrated commutation electronics with switch power supply
– Protective extra-low voltage 24 / 48 VDC
AC
Note: Switch power supply is not included but has to be ordered
as accessory.
598
DC
General
information
AC centrifugal,
backward
– minimal extra costs for additional functions (open / closed loop
control)
– Optional BUS interface
EC centrifugal,
backward
AC centrifugal,
forward
– Low-noise operation across the entire speed range
The motor restarts automatically after the following failures have
EC centrifugal, backward for clean rooms
– Speed setting via linear set value (0-10 VDC) or PWM signal
recognised by the electronics, and the motor is switched off.
been diagnosed:
– Line failure
– Phase failure
– Line under-voltage
– DC link voltage too high or too low
– Locked rotor
With the following types of failures, there is no automatic restart.
EC centrifugal,
forward
– High efficiency throughout the entire speed range
With AC-fed EC motors, certain faults in modes of operation are
Here, hardware or software reset is required:
– Motor temperature too high
– Temperature of cooling element or ambient temperature of
electronics too high
– Hall failure
EC-SYSTEMS
– Integrated EMC filter
recognised by the electronics, and the motor is automatically restarted.
Hardware reset
Switching off the fan and restarting it after one minute results in
hardware reset.
Software reset
Software reset is via ebmBUS and LISA software, hand-held control
Accessories
– Open and closed loop control as well as monitoring of the motor
With DC-fed EC motors, certain faults in modes of operation are
terminal, or PDA with Fan Control Software.
Technology
– Input for analogue and digital signals
Types of alarms and reactions with EC motors
599
Contacts
Typical features of the ebm-papst commutation electronics:
Electrical connections EC
G) EC motors (nominal voltage 24 / 48 VDC)
Notes on various control possibilities and their applications
Maximum ripple
±3.5%
red
33 K
4.7 K
Lin/PWM control input
0-10 VDC / PWM
yellow
Counter
Controller
U
PWM
white
10 K
12 V
Tach output
pulses per revolution
Isink max. 10 mA
680 Alarm
Speed display
12 V
47 V
Temperature
control module
Speed setting
Speed setting
with
potentiometer
PWM 1 - 10 kHz
50002-1-0174
50003-1-0174
Full speed
GND
blue
Speed setting
1 V - 10 V
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
start up at > 1.4 V
Customer circuit
Connection
Fan
+
GND
Tach
0-10 V
PWM
Line 1
red
blue
white
yellow
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
+
red
Maximum ripple ± 3.5 %
1
Tach
GND
blue
GND
white
2 pulses / revolution (M1G045 / M1G055)
0-10 V / PWM yellow
600
Tach output:
3 pulses / revolution (M1G074/M3G084)
Control input (Impedance 100 k)
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
H1) EC motors (size 055, line-fed)
Notes on various control possibilities and their applications
Umin = 15 V
L
brown
N
blue
Mains
50/60 Hz
+
-
EC centrifugal, backward for clean rooms
Imax =
10 mA
PE
green/yellow
+
Voltage output
+10 V max. 1.1 mA
U
-
10 K
red
12 V
Lin/PWM control input
0-10 VDC / PWM
Speed setting
1 V - 10 V
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Counter
Controller
white
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
Alarm
start up at > 1.4 V
Speed display
Customer circuit
Isink max. 10 mA
680 47 V
Connection
Fan
N
PE
+10 V
0-10 V
PWM
GND
Tach
Line 2
L
Line 1
EC-SYSTEMS
Full speed
brown
blue
green/yellow
red
yellow
blue
white
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L
brown
Mains 50/60 Hz, phase
2
+10 V
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Voltage output +10 V max. 1.1 mA
Control input (Impedance 100 k)
PE
green/yel
Protective earth
GND
blue
GND
Tach
white
Tach output: 1 pulse per revolution
red
Accessories
PWM 1 - 10 kHz
Speed setting
with variable
resistance
1 F
Technology
Speed setting
GND
blue
Tach output
1 pulse per revolution
EC centrifugal,
forward
yellow
601
Contacts
PWM
H2) EC motors (size 055, line-fed and constant air flow)
Notes on various control possibilities and their applications
Umin = 15 V
Imax =
10 mA
L
brown
N
blue
Mains
50/60 Hz
+
-
PE
green/yellow
+
Voltage output
+10 V max. 1.1 mA
U
PWM
-
10 K
red
Lin/PWM input for
set value
0-10 VDC / PWM
12 V
yellow
Air flow setting
PWM 1 - 10 kHz
Air flow setting
with variable
resistance
Max.
air flow
Air flow setting
1 V - 10 V
100% PWM -> Vmax
17% PWM -> Vmin
< 15% PWM -> V= 0m3/h
start up at > 1.4 V
Counter
GND
blue
Tach output
1 pulse per revolution
Controller
white
10 V -> Vmax
1.7 V -> Vmin
< 1.5 V -> V= 0m3/h
Alarm
start up at > 1.4 V
Speed display
Customer circuit
1 F
Isink max. 10 mA
680 47 V
Connection
N
PE
+10 V
0-10 V
PWM
GND
Tach
Line 2
L
Line 1
Fan
brown
blue
green/yellow
red
yellow
blue
white
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L
brown
Mains 50/60 Hz, phase
2
+10 V
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Voltage output +10 V max. 1.1 mA
Input for set value (impedance 100 k)
PE
green/yel
Protective earth
GND
blue
GND
Tach
white
Tach output: 1 pulse per revolution
602
red
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
J1) EC motors (size 074, line-fed)
Notes on various control possibilities and their applications
Umin = 15 V
L
black
N
blue
Mains
50/60 Hz
+
-
EC centrifugal, backward for clean rooms
Imax =
10 mA
PE
green/yellow
+
Voltage output
+10 V max. 1.1 mA
U
-
10 K
red
12 V
Lin/PWM control input
0-10 VDC / PWM
Speed setting
1 V - 10 V
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
start up at > 1.4 V
Counter
Controller
white
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
Alarm
start up at > 1.4 V
Speed display
Customer circuit
Isink max. 10 mA
680 47 V
Connection
Fan
N
PE
+10 V
0-10 V
PWM
GND
Tach
Line 2
L
Line 1
EC-SYSTEMS
Full speed
black
blue
green/yellow
red
yellow
blue
white
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L
black
Mains 50/60 Hz, phase
2
+10 V
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Voltage output +10 V max. 1.1 mA
Control input (Impedance 100 k)
PE
green/yel
Protective earth
GND
blue
GND
Tach
white
Tach output: 1 pulse per revolution
red
Accessories
PWM 1 - 10 kHz
Speed setting
with variable
resistance
1 F
Technology
Speed setting
GND
blue
Tach output
1 pulse per revolution
EC centrifugal,
forward
yellow
603
Contacts
PWM
J2) EC motors (size 074, line-fed and constant air flow)
Notes on various control possibilities and their applications
L
black
N
blue
Mains
50/60 Hz
10 K
+
-
PE
green/yellow
+
Voltage output
+10 V max. 1.1 mA
U
PWM
-
10 K
red
Lin/PWM input
for set value
0-10 VDC / PWM
12 V
yellow
Speed setting
PWM 1 - 10 kHz
Air flow setting
with variable
resistance
Max.
air flow
Air flow setting
1 V - 10 V
Counter
GND
blue
Tach output
1 pulse per revolution
Controller
white
100% PWM -> V=max
approx. 17% PWM -> V=min
< 15% PWM -> V=0
10 V -> V=max
approx. 1.7 V -> V=min
< 1.5 V -> V=0
Alarm
start up at > 1.4 V
start up at > 1.4 V
Speed display
Customer circuit
1 F
Isink max. 10 mA
680 47 V
Connection
GND
Tach
green/yellow
0-10 V
PWM
blue
+10 V
N
black
Line 2
PE
L
Line 1
Fan
red
yellow
blue
white
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L
black
Mains 50/60 Hz, phase
2
+10 V
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Voltage output +10 V max. 1.1 mA
Input for set value (impedance 100 k)
PE
green/yel
Protective earth
GND
blue
GND
Tach
white
Tach output: 1 pulse per revolution
604
red
General
information
AC centrifugal,
backward
AC centrifugal,
forward
EC centrifugal,
backward
K1) EC motors (size 084, line-fed)
Notes on various control possibilities and their applications
Umin = 15 V
Mains
50/60 Hz
U
-
10 K
+
-
NC
white1
COM
white2
Voltage output
red
+10 V
max. 1.1 mA
+
PWM
L
black
N
blue
PE
green/yellow
12 V
EC centrifugal, backward for clean rooms
Imax =
10 mA
Alarm relay:
Break for failure
(2 A, 250 VAC, AC1)
1 F
GND
blue
Speed setting
with variable
resistance
Full speed
Speed setting
1 V - 10 V
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 1.4 V
Customer circuit
Connection
+10 V
0-10 V
PWM
GND
green/yellow white1
COM
blue
Line 2
NC
N
black
PE
L
Line 1
Fan
white2
red
yellow
blue
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L
black
Mains 50/60 Hz, phase
2
+10 V
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Voltage output +10 V max. 1.1 mA
Control input (Impedance 100 k)
PE
green/yel
Protective earth
GND
GND
NC
white1
Alarm relay, break for failure
COM
white2
Alarm relay, COMMON
red
blue
Accessories
start up at > 1.4 V
EC-SYSTEMS
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
Technology
PWM 1 - 10 kHz
605
Contacts
Speed setting
EC centrifugal,
forward
Lin/PWM control input
yellow
0-10 VDC /
PWM
K2) EC motors (size 084/112 with ebmBUS, mains-powered)
Connector Connection Assignment / function
KL1
606
0V
+15 V
RS A
RS B
KL2
L
N
PE
KL1
Connector Connection Assignment / function
PE
Protective earth
RS B
RS485 interface for ebmBUS; RS B
N
Mains 50/60 Hz, neutral
RS A
RS485 interface for ebmBUS; RS A
L
Mains 50/60 Hz, phase
+15 V
Operation: +15 V (50 mA); Alarm: 0 V
0V
Operation: 0 V; Alarm: +15 V (50 mA)
KL2
General
information
AC centrifugal,
backward
AC centrifugal,
forward
Connector Connection Assignment / function
Connector Connection Assignment / function
PE
PE
Protective earth
KL3
KL1
N
Mains 50/60 Hz, neutral
L
Master output 0-10 V max. 3 mA
GND
Mains 50/60 Hz, phase
GND
0-10 V / PWM Control / Actual value input (Impedance 100 k)
NC
Alarm relay, break for failure
+10 V
COM
Alarm relay, COMMON (2A, 250 VAC, AC1)
NO
Alarm relay, make for failure
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
+20 V
Supply for external sensor,
4-20 mA
Control / Actual value input
20 VDC (±20 %) @ 50 mA
GND
GND
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
EC centrifugal,
forward
0-10 V / PWM Control / Actual value input
PE
L3
Connector Connection Assignment / function
Connector Connection Assignment / function
PE
PE
Protective earth
KL3
KL1
L3
Mains; L3
L2
Mains; L2
GND
0-10 V / PWM Control / Actual value input (Impedance 100 k)
L1
Mains; L1
+10 V
NC
Alarm relay, break for failure
COM
Alarm relay, COMMON (2A, 250 VAC, AC1)
NO
Alarm relay, make for failure
Master output 0-10 V max. 3 mA
GND
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
+20 V
Supply for external sensor,
4-20 mA
Control / Actual value input
20 VDC (±20 %) @ 50 mA
0-10 V / PWM Control / Actual value input
GND
GND
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
Technology
KL2
OUT
Accessories
L1
L2
KL1
NC
COM
NO
OUT
GND
+10 V
0-10 V
PWM
+20 V
KL2
4-20 mA
GND
0-10 V
PWM
RS B
RS A
RS B
RS A
KL3
EC-SYSTEMS
L2) EC motors (size 112, three-phase mains-powered)
607
Contacts
KL2
OUT
EC centrifugal, backward for clean rooms
L
N
PE
KL1
NC
COM
NO
OUT
GND
+10 V
0-10 V
PWM
+20 V
KL2
4-20 mA
GND
0-10 V
PWM
RS B
RS A
RS B
RS A
KL3
EC centrifugal,
backward
L1) EC motors (size 112, single-phase mains-powered)
M) EC motors (size 150, three-phase mains-powered)
PE
L3
L1
L2
KL1
NC
COM
NO
OUT
GND
+10 V
0-10 V
PWM
+20 V
KL2
4-20 mA
GND
0-10 V
PWM
RS B
RS A
RS B
RS A
KL3
Connector Connection Assignment / function
Connector Connection Assignment / function
PE
PE
Protective earth
KL3
KL1
L3
Mains; L3
L2
Mains; L2
GND
0-10 V / PWM Control / Actual value input (Impedance 100 k)
L1
Mains; L1
+10 V
NC
Alarm relay, break for failure
COM
Alarm relay, COMMON (2A, 250 VAC, AC1)
NO
Alarm relay, make for failure
KL2
OUT
Master output 0-10 V max. 3 mA
GND
Supply for external potentiometer,
10 VDC (+10 %) @ 10 mA
+20 V
Supply for external sensor,
4-20 mA
Control / Actual value input
20 VDC (±20 %) @ 50 mA
0-10 V / PWM Control / Actual value input
608
GND
GND
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
Technology
Accessories
EC-SYSTEMS
PE
L3
L2
L1
NC
COM
Slave
Mains
50/60 Hz
EC centrifugal,
forward
PE
L3
L2
L1
NC
COM
NO
OUT
GND
0-10 V
PWM
+10 V
+20 V
Master
Mains
50/60 Hz
EC centrifugal, backward for clean rooms
EC centrifugal,
backward
Alarm relay
609
Contacts
PE
L3
L2
L1
NC
COM
NO
OUT
GND
0-10 V
PWM
+10 V
+20 V
4-20 mA
0-10 V
PWM
GND
RS B
RS A
RS B
RS A
Pressure
sensor
NO
OUT
GND
0-10 V
PWM
+10 V
+20 V
4-20 mA
0-10 V
PWM
GND
RS B
RS A
RS B
RS A
PC with interface
converter (RS485)
4-20 mA
0-10 V
PWM
GND
RS B
RS A
RS B
RS A
Connection diagram: Condensing pressure control with master-slave fans
Mains
50/60 Hz
Slave
AC centrifugal,
forward
AC centrifugal,
backward
General
information
fan agent
compact fan agent
Distributors, agencies and subsidiaries
motor specialist
motor agent
Germany
ebm-papst
Mulfingen GmbH & Co. KG
ebm-papst
St. Georgen GmbH & Co. KG
ebm-papst
Landshut GmbH
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 79 38 / 81-0
Fax +49 (0) 79 38 / 81-110
info1@de.ebmpapst.com
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 (0) 77 24 / 81-0
Fax +49 (0) 77 24 / 81-13 09
info2@de.ebmpapst.com
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 (0) 8 71 / 707-0
Fax +49 (0) 8 71 / 707-465
info3@de.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
Contacts
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 (0) 30 / 94 41 49 62
Fax +49 (0) 30 / 94 41 49 63
Jens.Duchow@de.ebmpapst.com
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 (0) 29 25 / 80 04 07
Fax +49 (0) 29 25 / 80 04 08
Hans-Joachim.Pundt@de.ebmpapst.com
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr. Hermann-Krause Straße 23
D-63452 Hanau
Phone +49 (0) 61 81 / 18 98 12
Fax +49 (0) 61 81 / 18 98 13
Christian.Kleffmann@de.ebmpapst.com
Halle
Dipl.-Ing. (TU) Michael Hanning
Lerchenweg 4
D-06120 Lieskau
Phone +49 (0) 3 45 / 5 51 24 56
Fax +49 (0) 3 45 / 5 51 24 57
Michael.Hanning@de.ebmpapst.com
Hamburg
Ingenieurbüro Breuell GmbH
Dirk Kahl
Elektroingenieur
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 10
Fax +49 (0) 40 / 53 80 92 84
Dirk.Kahl@de.ebmpapst.com
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 38
D-35075 Gladenbach
Phone +49 (0) 64 62 / 40 71 10
Fax +49 (0) 64 62 / 40 71 11
Ralph.Brueck@de.ebmpapst.com
610
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 (0) 26 57 / 16 96
Fax +49 (0) 26 57 / 16 76
Winfried.Schaefer@de.ebmpapst.com
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Steinbergweg 6
D-82285 Hattenhofen
Phone +49 (0) 81 45 / 80 92 25
Fax +49 (0) 81 45 / 80 92 26
Jens.Peter@de.ebmpapst.com
Nuremberg
Friedrich Klein
Adlerstraße 49/1
D-73540 Heubach
Phone +49 (0) 71 73 / 49 83
Fax +49 (0) 71 73 / 80 53
Friedrich.Klein@de.ebmpapst.com
Offenburg
Dipl.-Ing (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 (0) 78 02 / 98 22 52
Fax +49 (0) 78 02 / 98 22 53
Ralf.Braun@de.ebmpapst.com
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Mühlhaldenweg 13
D-73207 Plochingen
Phone +49 (0) 71 53 / 92 89 80
Fax +49 (0) 71 53 / 92 89 81
Rudi.Weinmann@de.ebmpapst.com
Ulm
Günter Wilhelm
Allgäuer Straße 7
D-89269 Vöhringen
Phone +49 (0) 73 06 / 92 46 08
Fax +49 (0) 73 06 / 92 46 48
Guenter.Wilhelm@de.ebmpapst.com
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 (0) 61 06 / 84 10
Fax +49 (0) 61 06 / 84 11 11
info@red-elektromechanik.de
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
info@breuell.de
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 (0) 81 04 / 8 97 0
Fax +49 (0) 81 04 / 8 97 90
info@schweiger-gmbh.de
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
ebm@breuell.de
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstraße 1
D-74677 Dörzbach
Phone +49 (0) 79 37 / 80 29 68
Fax +49 (0) 79 37 / 80 25 78
info@hds-gmbh.net
General
information
AC centrifugal,
backward
Croatia
ebm-papst Industries Kft.
Mátyás u. 1/A
H-2220 Vecsés
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
office@hu.ebmpapst.com
www.ebmpapst.hu
Cyprus
MATERO LTD
37, St. Kyriakides Avenue
P.O. Box 51744
CY-3080 Limassol
Phone +357 / 25 / 87 00 30
Fax +357 / 25 / 38 13 66
matero@cytanet.com.cy
www.matero.com.cy
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 / 9 / 88 70 22 0
Fax +358 / 9 / 88 70 22 13
mailbox@ebmpapst.fi
www.ebmpapst.fi
France
ebm-papst SARL
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai-Cedex
Phone +33 / 820 326 266
Fax +33 / 3 / 88 67 38 83
info@ebmpapst.fr
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 / 210 / 951 37 05
Fax +30 / 210 / 951 34 90
contact@helcoma.gr
www.helcoma.gr
EC centrifugal, backward for clean rooms
Ireland
ebm-papst Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 / 57 86 / 643 43
Fax +353 / 57 86 / 643 46
sales@ie.ebmpapst.com
www.ebmpapst.ie
EC centrifugal,
forward
Estonia
ebm-papst Oy
Eesti Filiaal
Kadaka tee 3
EST-10621 Tallinn
Phone +372 / 655 / 6978
Fax +372 / 655 / 6979
EC centrifugal,
backward
AC centrifugal,
forward
Bulgaria
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
dudasludovic@xnet.ro
Iceland
RJ Engineers
Stangarhyl 1A
IS-110 Reykjavik
Phone +354 / 567 80 30
Fax +354 / 567 80 15
rj@rj.is
www.rj.is
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 / 03 31 / 83 62 01
Fax +39 / 03 31 / 82 15 10
info@it.ebmpapst.com
www.ebmpapst.it
EC-SYSTEMS
Belgium
VIBO Benelux B. V.
Sales office Belgium-Luxembourg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 / 16 / 39 62 00
Fax +32 / 16 / 39 62 20
info@vibobenelux.com
www.vibobenelux.com
Denmark
Jenk A/S
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 / 43 / 63 11 11
Fax +45 / 43 / 63 05 05
jenk@jenk.dk
www.jenk.dk
Macedonia
ebm-papst Industries Kft.
Mátyás u. 1/A
H-2220 Vecsés
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
office@hu.ebmpapst.com
www.ebmpapst.hu
Accessories
Belarus
ebm-papst Bel AgmbH
Prospekt Nesavisimosti 11/2 Zimmer 325, 512
BY-220050 Minsk
Phone +375 / 17 / 209 95 61
Fax +375 / 17 / 209 95 61
info@by.ebmpapst.com
Hungary
ebm-papst Industries Kft.
Mátyás u. 1/A
H-2220 Vecsés
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
office@hu.ebmpapst.com
www.ebmpapst.hu
Netherlands
VIBO Benelux B. V.
Engelseweg 127
Postbus 230
NL-5705 AC Helmond
Phone +31 / 4 92 / 50 29 00
Fax +31 / 4 92 / 50 29 50
verkoop@vibobenelux.com
www.vibobenelux.com
Technology
Austria
ebm-papst Motoren & Ventilatoren GmbH
Westbahnstraße 5
A-4490 St. Florian
Phone +43 / 72 24 / 66 01 10
Fax +43 / 72 24 / 66 01 120
info@at.ebmpapst.com
www.ebmpapst.at
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Krátká 379
CZ-66461 Rajhradice u Brna
Phone +420 / 5 / 47 23 26 16
Fax +420 / 5 / 47 23 26 22
info@ebmpapst.cz
www.ebmpapst.cz
611
Contacts
Europe
fan agent
compact fan agent
Distributors, agencies and subsidiaries
motor specialist
motor agent
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 / 22 / 76 33 40
Fax +47 / 22 / 61 91 73
mailbox@ziehl-ebm.no
www.ziehl-ebm.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236Warszawa
Phone +48 / 22 / 675 78 19
Fax +48 / 22 / 676 95 87
office@ebmpapst.pl
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda
Av. Marechal Gomes da Costa, 35 e
Rua Conselheiro Emidio Navarro
P-1800-255 Lisboa
Phone +351 / 21 / 839 48 80
Fax +351 / 21 / 839 47 59
info@pt.ebmpapst.com
Romania
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
dudasludovic@xnet.ro
Russia
ebm-papst Ural GmbH
Rosa Luxembourg Strasse 59
RU-620026 Jekaterinburg
Phone +7 / 343 / 378 31 75
Fax +7 / 343 / 378 31 89
Konstantin.Molokov@ru.ebmpapst.com
www.ebmpapst.ur.ru
612
ebm-papst Rus GmbH
Nizhegorodskaya 32, str. 15 office 420
RU-109029 Moskau
Phone +7 / 495 / 671 53 93
Fax +7 / 495 / 671 53 95
info@ebmpapst.ru
www.ebmpapst.ru
ebm-papst Rus
Saint-Petersburg´s Filial
Zastavskaya 7
RU-196084 Sankt-Petersburg
Phone +7 / 812 / 449 96 07
Fax +7 / 812 / 449 96 07
spb@ru.ebmpapst.com
Serbia & Montenegro
ebm-papst Industries Kft.
Mátyás u. 1/A
H-2220 Vecsés
Phone +36 / 29 / 55 01 90
Fax +36 / 29 / 55 01 94
office@hu.ebmpapst.com
www.ebmpapst.hu
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 / 91 / 678 08 94
Fax +34 / 91 / 678 15 30
ventas@ebmpapst.es
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 / 8 / 761 94 00
Fax +46 / 8 / 36 23 06
info@ebmpapst.se
www.ebmpapst.se
Switzerland
ebm-papst AG
Rütisbergstraße 1
CH-8156 Oberhasli
Phone +41 / 44 / 732 20 70
Fax +41 / 44 / 732 20 77
verkauf@ebmpapst.ch
www.ebmpapst.ch
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 / 2 32 / 32 82 090 -91
Fax +90 / 2 32 / 32 80 270
akantel@akantel.com.tr
www.akantel.com.tr
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 47
UA-03067 Kiev
Phone +38 / 044 / 206 30 91
Fax +38 / 044 / 206 30 91
mail@ebmpapst.ua
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 / 12 45 / 46 85 55
Fax +44 / 12 45 / 46 63 36
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane, East Ilsley
GB-Berkshire RG20 7LG
Phone +44 / 87 07 / 66 51 70
Fax +44 / 87 07 / 66 51 80
A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com
General
information
AC centrifugal,
backward
AC centrifugal,
forward
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 / 313 / 406 80 80
Fax +1 / 313 / 406 80 81
automotive@us.ebmpapst.com
www.ebmpapst-automotive.us
EC centrifugal,
backward
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 / 11 / 794 34 34
Fax +27 / 11 / 794 50 20
info@za.ebmpapst.com
www.ebmpapst.co.za
EC centrifugal, backward for clean rooms
Brasil
ebm-papst Motores Ventiladores Ltda.
Rua Francisco D´Amico, 155
Bairro Pirajussara
BR-06785-290 Taboão da Serra-SP
Phone +55 /11 / 41 38 50 90
Fax +55 /11 / 41 38 50 86
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Africa
EC centrifugal,
forward
Argentinia
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 / 11 46 57 61 35
Fax +54 / 11 46 57 20 92
ventas@ar.ebmpapst.com
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 / 860 / 674 15 15
Fax +1 / 860 / 674 85 36
sales@us.ebmpapst.com
www.ebmpapst.us
EC-SYSTEMS
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 / 905 / 420 / 35 33
Fax +1 / 905 / 420 / 37 72
sales@ca.ebmpapst.com
www.ebmpapst.ca
Technology
Accessories
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 / 55 / 50 91 44 44
Fax +52 / 55 / 50 91 44 43
sales@mx.ebmpapst.com
www.ebmpapst.com.mx
613
Contacts
America
fan agent
compact fan agent
Distributors, agencies and subsidiaries
motor specialist
motor agent
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 / 21 / 50 46 01 83
Fax +86 / 21 / 50 46 11 19
sales@cn.ebmpapst.com
Hong Kong
ebm-papst Ventilator (Shanghai) Co., Ltd.
Hong Kong Representative Office
Unit Nos. 13, 9/F, Technology Park
18 On Lai Street, Sha Tin, N.T.
HK-Hong Kong P.R. of China
Phone +852 / 21 45 / 86 78
Fax +852 / 21 45 / 76 78
chenghong@cn.ebmpapst.com
India
ebm NADI International Pvt Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 / 44 / 25 37 25 56
Fax +91 / 44 / 25 37 11 49
ebmnadi@md2.vsnl.net.in
www.ebmnadi.com
Indonesia
ebm-papst Indonesia
Representative Office
Jalan Puri Kencana, Blok K7/3T
RI-Jakarta 11610
Phone +62 / 21 / 582 / 31 18
Fax +62 / 21 / 582 / 31 17
sonny.sanjaya@id.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 / 3 / 910 03 00
Fax +972 / 3 / 579 66 79
polak@polak.co.il
614
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 / 45 / 470 / 57 51
Fax +81 / 45 / 470 / 57 52
info@jp.ebmpapst.com
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 / 2 / 36 62 / 13 24
Fax +82 / 2 / 36 62 / 13 26
info@kr.ebmpapst.com
www.ebmpapst.co.kr
Thailand
ebm-papst Thailand Co. Ltd.
Representative Office
99/349 Chaeng Wattana Road, Laksi
Bangkok 10210, Thailand
Phone +66 / 2 / 576 / 15 24-5
Fax +66 / 2 / 576 / 15 42
salesdept@th.ebmpapst.com
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 / 4 / 886 08 26
Fax +971 / 4 / 886 08 27
info@ae.ebmpapst.com
Australia
Australia
ebm-papst Australia Pty Ltd.
2 Silverton Close
AUS-Laverton North, Victoria, 3026
Phone +61 / 3 / 83 25 64 00
Fax +61 / 3 / 83 25 64 64
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst Australia Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 / 9 / 837 18 84
Fax +64 / 9 / 837 18 99
sales@ebmpapst.com.au
www.ebmpapst.com.au
Malaysia
ebm-papst Malaysia
Representative Office
Block F1, 9A-4, Jalan PJU 1/42
Dataran Prima
MAL-47301 Petaling Jaya
Phone +60 / 3 / 78 06 54 40
Fax +60 / 3 / 78 06 54 41
john.bulder@my.ebmpapst.com
Singapore
ebm-papst SEA Pte. Ltd.
23 Ubi Road 4, #05-00
Olympia Industrial Building
SGP-Singapore 408620
Phone +65 / 68 42 84 38
Fax +65 / 68 42 84 39
salesdept@sg.ebmpapst.com
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 / 7 / 557 42 68
Fax +886 / 7 / 557 27 88
eteco@ms22.hinet.net
615
fan agent
compact fan agent
Distributors, agencies and subsidiaries
motor specialist
motor agent
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 / 21 / 50 46 01 83
Fax +86 / 21 / 50 46 11 19
sales@cn.ebmpapst.com
Hong Kong
ebm-papst Ventilator (Shanghai) Co., Ltd.
Hong Kong Representative Office
Unit Nos. 13, 9/F, Technology Park
18 On Lai Street, Sha Tin, N.T.
HK-Hong Kong P.R. of China
Phone +852 / 21 45 / 86 78
Fax +852 / 21 45 / 76 78
chenghong@cn.ebmpapst.com
India
ebm NADI International Pvt Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 / 44 / 25 37 25 56
Fax +91 / 44 / 25 37 11 49
ebmnadi@md2.vsnl.net.in
www.ebmnadi.com
Indonesia
ebm-papst Indonesia
Representative Office
Jalan Puri Kencana, Blok K7/3T
RI-Jakarta 11610
Phone +62 / 21 / 582 / 31 18
Fax +62 / 21 / 582 / 31 17
sonny.sanjaya@id.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 / 3 / 910 03 00
Fax +972 / 3 / 579 66 79
polak@polak.co.il
614
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 / 45 / 470 / 57 51
Fax +81 / 45 / 470 / 57 52
info@jp.ebmpapst.com
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 / 2 / 36 62 / 13 24
Fax +82 / 2 / 36 62 / 13 26
info@kr.ebmpapst.com
www.ebmpapst.co.kr
Thailand
ebm-papst Thailand Co. Ltd.
Representative Office
99/349 Chaeng Wattana Road, Laksi
Bangkok 10210, Thailand
Phone +66 / 2 / 576 / 15 24-5
Fax +66 / 2 / 576 / 15 42
salesdept@th.ebmpapst.com
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 / 4 / 886 08 26
Fax +971 / 4 / 886 08 27
info@ae.ebmpapst.com
Australia
Australia
ebm-papst Australia Pty Ltd.
2 Silverton Close
AUS-Laverton North, Victoria, 3026
Phone +61 / 3 / 83 25 64 00
Fax +61 / 3 / 83 25 64 64
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst Australia Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 / 9 / 837 18 84
Fax +64 / 9 / 837 18 99
sales@ebmpapst.com.au
www.ebmpapst.com.au
Malaysia
ebm-papst Malaysia
Representative Office
Block F1, 9A-4, Jalan PJU 1/42
Dataran Prima
MAL-47301 Petaling Jaya
Phone +60 / 3 / 78 06 54 40
Fax +60 / 3 / 78 06 54 41
john.bulder@my.ebmpapst.com
Singapore
ebm-papst SEA Pte. Ltd.
23 Ubi Road 4, #05-00
Olympia Industrial Building
SGP-Singapore 408620
Phone +65 / 68 42 84 38
Fax +65 / 68 42 84 39
salesdept@sg.ebmpapst.com
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 / 7 / 557 42 68
Fax +886 / 7 / 557 27 88
eteco@ms22.hinet.net
615
37777-7-8811 • KO-08/07-12’
Printed in Germany
ebm-papst
ebm-papst
ebm-papst
Mulfingen GmbH & Co. KG
St.Georgen GmbH & Co. KG
Landshut GmbH
Bachmühle 2
Hermann-Papst-Straße 1
Hofmark-Aich-Straße 25
D-74673 Mulfingen
D-78112 St.Georgen
D-84030 Landshut
Phone +49 (0) 7938 / 81-0
Phone +49 (0) 7724 / 81-0
Phone +49 (0) 871/ 707-0
Fax +49 (0) 7938 / 81-110
Fax +49 (0) 7724 / 81-1309
Fax +49 (0) 871 / 707-465
info1@de.ebmpapst.com
info2@de.ebmpapst.com
info3@de.ebmpapst.com
Centrifugal fans and blowers
version 07
Centrifugal fans and blowers
www.ebmpapst.com
The engineer’s choice
version 07
Download