Uploaded by Gurwinder Aulakh

MSP-4070 C1000N6B Sound Data Sheet

advertisement
Sound data sheet
C1000N6B 60 Hz spark-ignited generator set (GenSet)
Sound pressure levels (SPLs) with radiator cooling package
A-weighted SPLs in dB(A) @ 7 meters
GenSet
configuration
Unhoused
with
infinite exhaust
Housed
with level II
soundattenuated
enclosure and
muffler
Microphone position*
Applied
standby
load
No load
1
2
3
4
5
6
7
8
87.8
93.1
92.6
95.8
93.1
93.8
94.3
93.3
50% load
88.1
93.3
92.8
95.9
93.2
93.8
94.6
93.5
93.5
75% load
88.4
93.5
93.2
96.0
92.8
93.9
94.7
93.7
93.7
Full load
89.0
94.1
93.6
96.2
92.8
94.1
94.9
93.9
94.0
No load
84.4
85.9
81.9
83.3
82.6
81.6
78.4
85.0
83.4
50% load
84.3
86.0
82.1
83.3
82.5
81.2
78.4
84.7
83.3
75% load
84.1
85.8
82.0
83.0
82.0
80.8
78.6
84.3
83.1
Full load
84.1
85.9
82.3
83.0
82.2
81.0
79.1
84.4
83.2
8 position
average SPL *Position 1 faces
the GenSet front.
93.4
The positions
proceed around
the GenSet in a
counter-clockwise
direction in 45°
increments. All
positions are
approximately 7 m
(23 ft.) from the
surface of the
GenSet and
approximately 1.2 m
(48 in) from floor
level.
Average A-weighted SPLs in dB(A)@ 1 meter
GenSet
configuration
Unhoused
with
infinite exhaust
Housed
with level II
soundattenuated
enclosure and
muffler
measured from a reference parallelepiped creating a hemisphere around the GenSet
Octave band center frequency, Hz
Applied
standby
16
32
63
125
250
500
1000
2000
4000
8000
load
No load
N/A
51.3
71.1
91.5
93.5
95.2
94.6
92.2
88.1
81.7
68.6
Total
SPL
100.9
16000
50% load
N/A
51.6
71.4
91.5
93.5
95.3
94.6
92.5
88.4
82.7
69.1
101.0
75% load
N/A
51.5
71.3
91.7
93.6
95.3
94.7
93.0
88.6
83.9
71.0
101.2
Full load
N/A
51.6
71.4
91.8
93.6
95.3
95.0
93.6
89.1
87.0
71.9
101.5
No load
N/A
49.3
65.2
88.2
86.2
84.3
79.9
79.1
73.2
67.0
53.0
91.9
50% load
N/A
50.0
65.5
88.0
86.2
84.4
80.1
79.6
73.8
67.3
53.8
91.9
75% load
N/A
50.2
65.6
87.7
86.4
84.5
80.5
80.3
74.9
69.4
59.8
92.0
Full load
N/A
51.5
65.6
87.6
86.6
85.2
81.5
81.2
76.3
71.4
63.2
92.3
A-weighted SPLs in dB(A)@ the operator location
GenSet
configuration
Unhoused
with
infinite exhaust
Housed with
level II encl
and muffler
MSP-4070 C1000N6B
November 2021
Applied
standby
load
75% load
measured at 1 meter from the GenSet control panel at 1.5 meter height
Octave band center frequency, Hz
16
32
63
125
250
500
1000
2000
4000
8000
16000
N/A
51.8
72.5
86.4
91.9
96.7
97.2
95.6
89.1
84.0
72.8
Total
SPL
102.2
Full load
N/A
51.8
72.6
86.4
92.0
96.7
97.4
96.5
89.7
87.6
73.5
102.6
75% load
N/A
46.9
67.1
87.6
81.4
79.9
73.7
75.6
66.9
67.0
58.9
89.5
Full load
N/A
46.8
66.8
87.4
81.4
79.8
74.1
77.0
67.9
70.0
62.5
89.4
cummins.com
Sound power levels (SPWLs) with radiator cooling package
A-weighted SPWLs in dB(A) @ 1 meter
measured from a reference parallelepiped creating a hemisphere around the GenSet
GenSet
configuration
Unhoused
with
infinite exhaust
Housed
with level II
soundattenuated
enclosure and
muffler
Octave band center frequency, Hz
Applied
standby
load
No load
16
32
63
125
250
500
1000
2000
4000
8000
16000
N/A
72.5
92.3
112.7
114.7
116.4
115.8
113.4
109.3
102.9
89.8
Total
SPWL
122.1
50% load
N/A
72.8
92.6
112.7
114.7
116.5
115.8
113.7
109.6
103.8
90.3
122.2
75% load
N/A
72.7
92.5
112.9
114.8
116.5
115.9
114.2
109.8
105.1
92.2
122.4
Full load
N/A
72.8
92.6
112.9
114.8
116.5
116.2
114.8
110.3
108.2
93.1
122.7
No load
N/A
72.3
88.2
111.2
109.2
107.3
102.9
102.1
96.2
90.0
76.0
114.9
50% load
N/A
73.0
88.5
111.0
109.2
107.4
103.1
102.6
96.8
90.3
76.8
114.9
75% load
N/A
73.2
88.6
110.7
109.4
107.5
103.5
103.3
97.9
92.4
82.9
115.0
Full load
N/A
74.5
88.6
110.6
109.6
108.2
104.6
104.2
99.3
94.4
86.2
115.3
A-weighted exhaust SPWLs in dB(A) @ 1 meter
measured 1 meter from the exhaust termination
GenSet
configuration
Unhoused
open exhaust
with tail pipe
Applied
standby
load
Octave band center frequency, Hz
16
32
63
125
250
500
1000
2000
4000
8000
16000
Total
SPWL
No load
N/A
65.3
88.0
106.9
111.4
108.1
96.4
93.5
83.1
76.2
59.6
114.1
50% load
N/A
54.4
91.4
106.5
110.9
112.3
106.4
103.8
101.5
97.7
83.2
116.3
75% load
N/A
60.3
92.3
108.0
113.0
115.5
110.1
109.8
108.4
101.9
92.5
119.6
Full load
N/A
61.8
92.7
111.4
114.9
117.9
114.1
113.4
112.7
107.9
101.4
122.6
Published sound levels are measured at a CE certified test site and are subject to instrumentation measurement, installation, and
manufacturing variability. The reference SPL is 20 µPa. The reference SPWL is 1 pW (10-12 W). SPLs and SPWLs at 1 meter from a reference parallelepiped creating a hemisphere around the GenSet are measured per the requirements of ISO 3744 and ISO 8528-10.
Exhaust SPWLs at 1 meter are calculated per ISO 6798, Annex A.
An unhoused (open set) configuration GenSet refers to a GenSet with no sound enclosure of any kind. A housed (closed set)
configuration GenSet refers to a GenSet that has a Level II (noise reduction) sound enclosure installed over the GenSet. The Level II
enclosure is integrally attached to the skid base of the GenSet.
The sound data for a GenSet with infinite exhaust does not include the exhaust noise contribution. The exhaust sound data for a GenSet
is solely exhaust noise and does not include noise from any other noise sources.
MSP-4070 C1000N6B
November 2021
cummins.com
2