Products Solutions Classification of Hazardous Areas Installation considerations for hazardous areas INTERNAL Slide 1 07/15/2016 P.Conen Services Classification of Hazardous Areas The world of hazardous classification INTERNAL Slide 2 07/15/2016 P.Conen Classification of Hazardous Areas ATEX / IEC Ex Device declaration Use the device under ground or above ground ? In which Zone you can use the device ? How the device is designed to avoid an explosion ? What is the max ignition energy can be exposed from the device ? What max ignition surface temp can appear on the device ? Ta & Tp !!! In which Zone you can use the device ? Equipment group Equipment category Protection Type Gas group Temperature class Equipment Protection Level ATEX II 1/2G Ex de IIC T2-T6 Ga/Gb IECEx - - Ex de IIC T2-T6 Ga/Gb Explosion Protection (CP00021Z) - 18 12-15 6 6 18 Explanation table based on Safety Instructions Liquiphant M/S (XA00108F-G) INTERNAL Slide 3 07/15/2016 P.Conen Classification of Hazardous Areas Equipment group - ATEX I II • Under ground (mining, etc) • Special requirements to the housing, besides Ex. • E+H does not provide instruments • all above ground applications • E+H does provide instruments IECEx covers this equipment class classification (e.g. Ga/Gb) INTERNAL Slide 4 07/15/2016 P.Conen Classification of Hazardous Areas Zone Classification according to ATEX Zones are classified according the probability of the occurrence of explosive mixtures Occurrence of Gas mixtures Dust mixtures Not likely to occur or only for short period Zone 2 Zone 22 Likely to occur occasionally Zone 1 Zone 21 Continuously or for long periods or frequently Zone 0 Zone 20 Zone 2 Zone 1 explosive atmosphere Zone 0 Fluid INTERNAL Slide 5 07/15/2016 P.Conen Classification of Hazardous Areas Equipment classification according to ATEX Equipment category Group I Mining industry Normal level of protection (safe without fault) Group II (IIA/IIB/IIC) Gas-/Dust-Ex 3G/3D High level of protection (safe with 1 fault) M2 2G/2D Very high level of protection (safe with 2 faults) M1 1G/1D INTERNAL Slide 6 07/15/2016 P.Conen Normal level of protection (safe without fault) Classification of Hazardous Areas Equipment classification according to IEC Equipment category Group I Mining industry Normal level of protection (safe without fault) Group II (IIA/IIB/IIC) Gas-Ex Group III (IIIA/IIIB/IIIC) Dust-Ex Gc Dc High level of protection (safe with 1 fault) Mb Gb Db Very high level of protection (safe with 2 faults) Ma Ga Da INTERNAL Slide 7 07/15/2016 P.Conen Ignition energy IIC>IIB>IIA • • • IIIA flyings IIIB non –conductive dusts IIIC conductive dusts (IIIC>IIIB>IIIA) Classification of Hazardous Areas Equipment designation to zones Gas - Ex Zone 0 Zone 1 Zone 2 ATEX category 1G 1G or 2G 1G or 2G or 3G IEC (EPL*) Ga Ga or Gb Ga or Gb or Gc Dust - Ex Zone 20 Zone 21 Zone 22 ATEX category 1D 1D or 2D 1D or 2D or 3D IEC (EPL*) Da Da or Db Da or Db or Dc * EPL = Equipment Protection Level INTERNAL Slide 8 07/15/2016 P.Conen Classification of Hazardous Areas Classification of flammable gases, vapors, mists INTERNAL Hot surface Sparks Ignition temperature Ignition energy Temperature class T1 … T6 Gas-Group A…C Slide 9 07/15/2016 P.Conen Classification of Hazardous Areas Ignition temperature – surface temperature Fuels Ignition temperature Apparatus Temperature class T1 >450°C Ignition temperature of gas INTERNAL Slide 10 Max. surface temperature 450°C >300°C … ≤450°C T2 300°C >200°C … ≤300°C T3 200°C >135°C … ≤200°C T4 135°C >100°C … ≤135°C T5 100°C >85°C … ≤100°C T6 85°C 07/15/2016 P.Conen Surface temperature depends on: • Ambient temperature • Process temperature • Internal heating sources (e.g. electrical components) Classification of Hazardous Areas Ignition temperature – surface temperature 600 Ignition temperature of gas 500 Surface temperature of apparatus 400 300 200 100 0 INTERNAL T1 >450°C Slide 11 T2 T3 T4 T5 >300°C ≤450°C >200°C ≤300°C >135°C ≤200°C >100°C ≤135°C 07/15/2016 P.Conen T6 >85°C ≤100°C Classification of Hazardous Areas Minimum ignition energy Ignition energy in relation to hydrogen and propane air/gas concentration INTERNAL Slide 12 07/15/2016 P.Conen Classification of Hazardous Areas Explosive concentrations of flammable mixtures INTERNAL Slide 13 07/15/2016 P.Conen Classification of Hazardous Areas Classification of flammable gases and dusts in groups Gas group Europe/IEC North America Min. ignition energy Examples A > 10 μJoules Acetylene, Carbon disulphide B > 20 μJoules Hydrogen B C > 60 μJoules Ethylether,Ethylene A D > 160 μJoules Acetone, Ammonia, Benzene, Butane, Cyclopropane, Ethanol, Gasoline, Hexane, Methanol Naphtha, Propane C Dust group Europe/IEC North America Kind of dust Examples - E Metal dusts - - F Coal dusts - - G Others - INTERNAL Slide 14 07/15/2016 P.Conen Classification of Hazardous Areas Classification of flammable gases, vapors, mists Classification of gases and vapors in explosion groups and temperature classes Gas-group I II A INTERNAL T1 T2 (>450°C) (>300°C ≤450°C) T3 (>200°C ≤300°C) T4 (>135°C ≤200°C) T5 (>100°C ≤135°C) T6 (>85°C ≤100°C) Methane Acetone Ethane Ammonia Benzene Ethanic acid Ethylacetate Kohlenoxyd Methanol Propane Toluol Ethyl alcohol i-Amylacetat n-Butane n-Butylalkohol II B Lighting gas Ethyl Ethyl oxyd II C Hydrogen Acetylene Slide 15 Gasoline Diesel fuel Aircraft fuel Heating oil n-Hexane Acetaldehyde Ether Ex IIB T3 07/15/2016 Ethyl glycol Ethyl ether Carbon disulphide P.Conen Classification of Hazardous Areas Protection types Protection measures Gas-Ex Oil immersion electrical parts are submersed in oil marking example EEx o T3 oil Pressurized apparatus EEx p T5 electrical parts are purged and pressurized with a protective gas (air or inert gas) Installation: purge and pressure control/shut down device Powder filling Slide 16 07/15/2016 air EEx q T4 electrical parts are submersed in a quartz powder INTERNAL p powder P.Conen Classification of Hazardous Areas Protection types Protection measures Gas Ex marking example Flameproof enclosure Ex db IIC T6 Increased safety Ex e T4 Intrinsic safety Ex ia IIC T4 internal explosion is confined by solid and flame tight enclosure Installation: Ex d cable entry or conduit systems or Ex e terminal prevention of ignition sources by fail safe design (only simple electric components) Limitation of the energy stored in the electrical circuits „simple“ apparatus, „associated“ apparatus, safety barriers Installation: safety values (Uo, Io, Po, Lo, Co) and clearences Advantage: Hot plugging for Ex ia, ib, ic without permission in the hazardous area! INTERNAL Slide 17 07/15/2016 P.Conen Classification of Hazardous Areas Types of protection of electrical apparatus Gas atmosphere (Equipment category / EPL) Type of protection Flameproof enclosures 1G / Ga 2G / Gb 3G / Gc da db dc eb ec ia ib ma mb Increased safety Intrinsically safety Encapsulation Oil immersion ob Powder filling qb Pressurized enclosures pxb/pyb 1D / Da 2D / Db 3D /Dc ic ia ib ic mc ma mb mc pb pc tb tc pzc Protection by enclosure ta Energy limited apparatus nL Restricted breathing enclosures nR Non sparking apparatus nA Sparking apparatus nC INTERNAL Slide 18 Dust atmosphere (Equipment category / EPL) 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? Cover sheet INTERNAL Slide 19 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? ? ? ? INTERNAL Slide 20 07/15/2016 P.Conen ? Page 11 Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? ? ? Page 12 INTERNAL Slide 21 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? ? Page 12 INTERNAL Slide 22 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? Slide 26 Slide 24 Slide 25 Page 14 INTERNAL Slide 23 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? ? ? ? Page 14 INTERNAL Slide 24 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? ? ? Page 15 INTERNAL Slide 25 07/15/2016 P.Conen Classification of Hazardous Areas Safety Instructions Liquiphant M/S (XA00108F-G) ? INTERNAL ? Slide 26 07/15/2016 P.Conen