Report No:- KNDT-ZAM-OCT-23-PAUT-492 Scanned Date:28-Oct-23 1 OF 3 Page:- PHASED ARRAY/TOFD INSPECTION REPORT PROBE AND WEDGE DETAILS Equipment Details Make: Model: OLYMPUS OMNI-MX2 Model OMNIX3-PA32128PR Module: Model S/N: Model Cal Due Date: Software Version: OMNI2-102405 QC-0082624 20-Nov-23 MXU-5.13 ENCODER INFORMATION Search Unit 1 (PA) Probe Make: Probe Model: Probe Freq: Cable (Type): Probe S/N: Wedge Matrl: Wedge Model Wedge Curvature: Olympus 5L64-A32 5MHz Fixed XAAB-10916-Y2283 Rexolite SA32 Flat Calibration (Step/mm) 12.02 Material Specification Search Unit 2 (TOFD) Search Unit 3 Search Unit 4 Material: Diameter: Nom Thickness: Temperature: Surface Condition: Couplant: TCG Ref Level: Cal Block Thick: CS 6Th CS Joint 17.5-14mm AMBIENT SMOOTH Gel/Water 75-85% FSH TCG BLOCK Reference Reflector Scan Resolution 1mm Scanning Speed 60mm/Sec Type: Ø1.5mm SDH SET-UP INFORMATIONS Group Element Used 1 1 Group o Offset (mm) Focal Distance Beam Resolution Ref dB Transfer dB Scanning dB Application Channel 0 ±20mm - 1 30.8 - 30.8 Perpendicular Scan Sectorial 0 ±20mm - 1 30.8 - 30.8 Perpendicular Scan Sectorial TOFD Resolution Ref dB Skew Angles( ) 49-64 90ᵒ 40-70 49-64 270ᵒ 40-70 Element Used Skew Angle PCS Transfer dB Scanning dB Definitions Application Abbrevations Index Point Position of the front of Wedge Relative to Weld Centerline S Surface Length Overall Length of the Flaw along the Circumferential Direction SS Sub-Surface Depth Measured Depth to the Bottom side of the Flaw Height % Amplitude Measured Vertical Height of the flaw Maximum Amplitude Response of the Signal Scanning Details Scan Plan: Scanner : Type of Scanning: Scan Overlap: Attached with Procedure HSMT Semi-Automatic 50mm (Min) Weld Details Configuration: Weld Process: Other Parameters Double V SAW Area of Restricted Access: Reject Settings: Two Side Access 0 Report No:- KNDT-ZAM-OCT-23-PAUT-492 28-Oct-23 Scanned Date:2 OF 3 Page:- PHASED ARRAY/TOFD INSPECTION REPORT PROJECT INFORMATION KNDT-SOP-PS-PAUT-31 Rev.00 Procedure No: Client: Al Zamil Metal Works Factory Project Name: WATER QUALITY IMPROVEMENT PROJECT- South Strategic Network & Reservoirs Dammam Project 5 Project Description POTABLE WATER STORAGE TANK Location CENTRAL,DAMMAM Equipment Tag no. D5-011-TK2 API 650 Acceptance Standard: D5-AWP-011-TK2-MEC-DD-005031 EXAMINATION DETAILS AND RESULTS Flaw Details Skew Location Start Point End Location Length (mm) Depth (mm) Height (mm) Type ±20 4722 , 4225 0-150 ID - - - - - - - - ACCEPTED 2 CS6-4 ±20 4722 , 4225 0-150 ID - - - - - - - - ACCEPTED Remarks Group CS6-3 Scan Distance (mm) 1 Welder ID Index Offset (mm) Result Serial No: Weld ID Image-1 Notes:1. Pointed indication found in PAUT. 2. Data lose in some area due to surface irregularity. SIVAGURUNATHAN Level III SHUKUR C A 29-Oct-23 29-10-2023 Operator NAME: Sub Contractor Contractor RAJESAB S AHMED MOSTAFA 29-10-2023 29-10-2023 SIGNATURE: DATE: Client Report No: KNDT-ZAM-OCT-23-PAUT-492 Image Number Image-1 S90 S270 S90 S270