62560- LED OLD STANDARD Clause 5 Eye protection- x Burning position- x Water mark- Additional Clause 6 N/A Clause 7 N/A Clause 8 N/A Clause 9 Additional, After torsion repeat electric strength test Axial strength for edison caps depends on the table while screwed in gauge Clause 10 N/A Clause 11 N/A Clause 12 N/A Clause 13 Change of 150 percent for extreme electrical conditions Clause 14 N/A Clause 15 Abnormal operation- Additional circuit illustrated in standard Clause 16 Test condition for dimmable lamps- Same circuit Clause 17 Photobiological Safety 17.1 UV Rad- Limit 2mW/klm - Tested in sphere - Table in logarithmic regression 17.2 Blue light hazard- IEC TR 62778 17.3 Infrared radiation- Marking that lamp are not expected to reach a level of infrared rad Clause 18 Ingress protection- for lamps that is consider IPX4 Clause 19 Information for luminaire design- other than IPX0