1 2 3 4 REVISION HISTORY A 6 7 8 NOTES: INDEX DATE DESIGNER DESCRIPTION --A 18-11-2020 Hall C. First issue --B 04-08-2022 Akash Palkar. Updated as per safety function instrumentation requirment. --C 04-11-2022 Akash Palkar. Please refer updated P&ID log sheet for details. --D 13-07-2023 Akash Palkar. For P&ID change Log, refer document ITER_D_8PJ4NU v1.0 --E 15-09-2023 Akash Palkar. For P&ID change Log, refer document ITER_D_8PJ4NU v1.0 Reference Drawings Legend Sheet :-ITER_Symbol_Legend_Specification_for_Flu_3ZSVRS_v3_0 VVPSS PFD :- 24VP00-PFD-001_7WP6SE_v5_1 A B B C C D D E Uncontrolled Once Printed 5 DESIGN AGENCY: TECHNICAL REFEREN CE: CREATED BY: SEE IDM APPROVER: SEE IDM E DATE: SEE IDM DIAGRAM TITLE: 24VPHM-PID-001 Hydrogen Mitigation System REVISION HISTORY SHEET PBS TITLE: Hydrogen Mitigation System DOCUMENT TYPE: SAFETY CLASS: F PID PBS NODE: 24VPHM 1 2 3 4 5 6 SIC-1 DATE OF ISSUE: QUALITY CLASS: QC-1 IO REFERENCE: Sep-2023 EXTERNAL REFERENCE: 7 __ A3 VERSION: __ 5PVPZU DESIGN AGENCY DOCUMENT Sheet Size: STATUS: --E 8 Sheet N°: 1/16 F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM 11-B1-01 TCWS Drain Tanks Upper Level L PI-4351 DN50 24VPHM-PID-001/15 24VPHM-PI-4351 16G DW water cleaning/spay S PI-8058 24VPHM-PID-001/03 24VPHM-PI-8058 1K S 24VP00 24VPHM MP 8052 LLT vent line H MP 8152 L MTE 8252 MTW 8252 L DN80/40 DN80/40 H MFT 8252 DI-8052 PI-8052 24VP00-PID-001/02 24VP00-PI-8052 16L VG-1050 DN80 DN80/20 DN20/80 ESPN NON-ESPN HMS-02 (LLT venting) J S Air supply From DTR MTW 1159 S MFT 1159 PI-8059 PI-1059 NON-ESPN ESPN PIC-N2 safe purge 16K MFT 1059 DN80 VG-1059 S DN25 VG-5051 H N1 I BIG-8051 TA-0631 To Sampling Pump (PL-8501) B N2 BIG-8151 N4 MTE 8253 DN25 VK-8354 MP 8154 DS-8051 MP 8155 PINST-8154 N04 DN50 N06 N16 N05 N15 N03 N01 N02 24VPHM-PID-001/06 24VPHM-PI-8552 13I PI-8054 PI-5101 24VPHM-PID-001/13 24VPHM-PI-5101 DN80 VK-8359 A DN80 MTW 1158 NON-ESPN ESPN VG-1159 PI-8050 MTW 1059 MTE 1159 DN40/25 MTW 1058 MTE 1158 DN80 I MTE 1059 PI-1159 MTE 1058 Note 3 N07 ML 8251 MTW 8253 T02 L01 P01 N13 DN15 DN80 H VG-8252 HMS-01 PI-8552 24VPRP-PID/03 24VPHM-PI-1050 14D DI-1050 PI-1050 VG-8151 MP 1151 DN50 MP 1051 MP 8055 MP 8054 PINST-8054 DN50 N14 To QEN (TA-0603) P02 L02 1I Note 6 G SP-0005 TA-0601 (PST) SP-0007 SP-0006 N17 MTW 8051 MTH 8051 T04 T01 MDS 8155 F T03 DN15 DN25 PI-3324 N10 SP-0003 VG-3355 N09 HX-0011 HX-0011 DN25 LO CHWS-H1 train A return PI-3003 VG-3353 DN65 Note 6 PI-3103 Note 6 24VPHM-PID-001/12 24VPHM-PI-3003 1I LO CHWS-H1 train B return 24VPHM-PID-001/12 24VPHM-PI-3103 1E D NON-ESPN ESPN N11 N2 DN25 16H 24VPHM-PID-001/15 24VPHM-PI-4356 D VK-8355 PI-8055 VG-5255 DW DN65 VG-3357 PI-5055 24VPHM-PID-001/13 24VPHM-PI-5055 N12 DN25 16I C PI-3241 HX-0010 E DN25 DN65 LO LC Note 6 PI-3102 24VPHM-PID-001/07 24VPHM-PI-3102 VG-3356 CHWS-H1 train B from HX-8191 HX-0010 LC DN65 VG-3354 N08 VG-3351 16H SP-0001 PI-3341 DN25 PI-3224 LC VG-3352 gamma detector MDS 8055 VG-3358 E MR 1251 LC 16J LO MTE 8251 SP-0002 MTW 8151 MTH 8151 MPH 1152 Note 6 MTW 8251 DN40 MPH 1052 PI-3002 Note 2 PI-8057 DN80 MPH 1151 24VPHM-PID-001/07 24VPHM-PI-3002 G DN40 MPH 1051 CHWS-H1 train A from HX-8091 24VPHM-PID-001/04 24VPHM-PI-8057 h1 DN80 11-B2-01 TCWS Drain Tanks F K MFT 1250 S SLT by-pass MP 1150 DN150 MTW 1250 PI-8051 MP 1050 VG-1150 VK-8350 DN80 VK-8352 ESPN NON-ESPN K J To PAR (TA-0602) MTE 1250 PI-1150 MP 8156 MP 8056 NON-ESPN ESPN PI-4356 To drainage distribution S PI-8551 1E VG-4256 DN40 DN65 Note 1 VK-8356 C 24VPHM-PID-001/14 24VPHM-PI-8551 PI-8056 DN40 To drainage distribution ( Refer P&ID 24VPHM-PID-001/10 ) Uncontrolled Once Printed B A B NOTES: 1. Fire protection to be applied for whole process system up to isolation valve 2. Vertical height h1 of overfilling line is sized to create overflow at correct level, when System is operating & differential pressure between PST and QEN head space of 5 kpa. 3. Igniters; BIG-2001 is sparking type, BIG-2101 is glow plug type. 4. Fire resistant thermal insulation with vapour barrier to avoid condensation at cold outer tank walls and risk of water accumulation in the bund (BA-0001) 5. Bellow sealed gate valves are used on pipelines potentially exposed to tritium. 6. This piping is classified as Non-ESPN. SHEET TITLE: MLH 1003 24VPHM-PID-001/02 DIAGRAM TITLE: 24VPHM-PID-001 BA-0001 Hydrogen Mitigation System Pool Scrubber Tank PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 2/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels 24 VP HM L Note 2 LC K From PST (TA-0601) 16K DN50 PI-8561 11-B1-01 TCWS Drain Tanks Upper Level MTE 8258 VG-8361 L MTW 8258 K PI-8058 24VPHM-PID-001/02 24VPHM-PI-8058 DN150 NON-ESPN ESPN DW for cleaning J 16H 24VPHM-PID-001/15 24VPHM-PI-4360 S PI-4360 PI-8060 DN40 DN40 VG-8160 J N1 N3 I I RV-8060 (PAR) H PAR Heaters G T1 MTW 8061 MTE 8061 T2 MTW 8062 MTE 8062 H HT-1060 G T3 MTW 8161 MTE 8161 T4 MTW 8162 MTE 8162 HT-1160 F F MR 1261 gamma detector E E N2 11-B2-01 TCWS Drain Tanks D MTW 8060 MTW 8160 DN50 MTE 8160 VG-8362 MTE 8060 PI-8562 Note 2 LC D To QEN (TA-0603) PI-8061 1J Uncontrolled Once Printed DN150 24VPHM-PID-001/04 24VPHM-PI-8061 C C B B NOTES: 1.Fire protection to be applied for whole process system up to isolation valve 2. For testing and re-activation 3. Bellow sealed gate valves are used on pipelines potentially exposed to tritium. SHEET TITLE: 24VPHM-PID-001/03 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM PASSIVE AUTOCATALYTIC REACTOR A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 3/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM 11-B2-01 TCWS Drain Tanks MFT 8271 L AH Process gas outlet to Wet Recombiner PI-8074 1J LC K NON-ESPN ESPN DW 24VPHM-PID-001/15 24VPHM-PI-4370 16F PI-4370 PI-8170 DN40 DN40 VG-8170 DN25 K VG-8373 PI-8573 DN150 24VPHM-PID-001/05 24VPHM-PI-8074 NOTE 2 To Sampling Pump (PL-8501) 13I 24VPHM-PID-001/06 24VPHM-PI-8552 DS-8074 From PAR (TA-0602) 16C J DN15 J PI-8572 VG-8272 PI-8061 24VPHM-PID-001/03 24VPHM-PI-8061 DN150 Process gas inlet I I From PST(TA-0601) PI-8057 24VPHM-PID-001/02 24VPHM-PI-8057 MTE 8071 DN40 Water overfilling line MP 8171 PINST-8171 DN50 N06 L02 ML 8271 DN50/40 16G N07 N01 N02 N05 N09 N03 MP 8071 MTW 8071 PINST-8071 DN50 N08 L01 T02 H H P01 TA-0603 (QEN) DN15 SP-1006 to OFT (TA-0606) PI-8073 1I G DN40 h1 N04 T01 SP-1009 MDS 8171 MTW 8171 G Overflow Line NOTE 3 DN50/40 MTE 8171 F MDS 8071 DN50 F 24VPHM-PID-001/06 24VPHM-PI-8073 SP-1010 MR 1271 Gamma detector E E N10 D D NON-ESPN ESPN N2 VG-5271 DN25 DW 16F VK-8371 PI-4372 24VPHM-PID-001/15 24VPHM-PI-4372 MP 8172 DN25 24VPHM-PID-001/13 24VPHM-PI-5071 PI-8071 16J PI-5071 MP 8072 To drainage distribution S PI-8571 1D VG-4272 C DN40 DN65 24VPHM-PID-001/14 24VPHM-PI-8571 VK-8372 C PI-8072 DN40 Uncontrolled Once Printed B B NOTE: 1.Fire protection to be applied for whole process system up to isolation valve 2. For commissioning/testing (bypass, gas analysis) 3. Vertical height h1 of overflow line is related to the differential pressure between the QEN and the OFT headspaces during operation 4. Bellow sealed gate valves are used on pipelines potentially exposed to tritium. SHEET TITLE: 24VPHM-PID-001/04 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM Quencher Tank A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 4/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-B1-01 TCWS Drain Tanks Upper Level K K NON-ESPN ESPN DW 16D J S 24VPHM-PID-001/15 24VPHM-PI-4375 PI-8175 PI-4375 DN40 DN40 VG-8175 J Process Gas from QEN 16K PI-8074 24VPHM-PID-001/04 24VPHM-PI-8074 DN150 Water from OFT 16E PI-8084 24VPHM-PID-001/06 24VPHM-PI-8084 DN25 VG-8384 I I MPD 8073 N1 N6 N4 N5 N3 H H RV-8070 F MTE 8072 MTW 8072 MTE 8172 MTW 8172 DN15 G PINST-8073 G F E E D D Process gas and liquid to OFT PI-8077 1K DN200 24VPHM-PID-001/06 24VPHM-PI-8077 C C B B Uncontrolled Once Printed NOTES: 1. Bellow sealed gate valves are used on pipelines potentially exposed to tritium. 2. Fire protection to be applied for whole process Piping. SHEET TITLE: 24VPHM-PID-001/05 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM WET RECOMBINER A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 5/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-B2-01 TCWS Drain Tanks Gas / Liquid inlet from Wet Recombiner 1K DN200 S DW 16E 24VPHM-PID-001/15 24VPHM-PI-4380 PI-4380 PI-8180 DN40 DN40 VG-8180 PI-8582 24VPHM-PID-001/07 24VPHM-PI-8087 K VG-8385 DN150 NON-ESPN ESPN DN25 K 24VPHM-PID-001/05 24VPHM-PI-8077 Gas outlet to EXC PI-8087 PI-8585 16C PI-8077 To Sampling Pump (PL-8501) NOTE-3 DN25/15 1E DN15 24VP00-PID-001/09 24VPHM-PI-8583 VG-8282 DS-8087 J J Condensate from EXC PI-8594 24VPHM-PID-001/07 24VPHM-PI-8594 DN40 Water overflow from QEN (TA-0603) 16G MP 8081 MP 8181 PI-8073 24VPHM-PID-001/04 24VPHM-PI-8073 DN40 PINST-8181 I DN50 Sample from PST MTE 8282 L02 N03 N08 N06 N09 DN80/40 16D MTW 8282 16I PINST-8081 ML 8281 N02 N05 T01 DN15 Sample from QEN DN50 16J N01 PI-8552 24VPHM-PID-001/02 24VPHM-PI-8552 PI-8572 24VPHM-PID-001/04 24VPHM-PI-8572 I DN15 L01 DN200 P01 SP-1010 H H TA-0606 MPD 8183 G MLH 8083 MPD 8083 MLH 8183 G DN15 F F MTE 8281 MTW 8281 T02 MP 8283 MFT 8283 To Wet Recombiner PI-8084 MR 1281 1I DN25 Gamma detector 24VPHM-PID-001/05 24VPHM-PI-8084 E E NON-ESPN ESPN N07 NG 16K MFT 8284 24VPHM-PID-001/13 24VPHM-PI-5081 VK-8381 VG-5281 DN25 PI-4382 VG-4282 DN40 PI-8083 VK-8382 PI-8084 DN50 S C VK-8084 DN25 DN25 VK-8386 PI-8184 DN50 VK-8184 PI-8082 DN25 D S To drainage distribution VG-8084 1D PI-8183 24VP00-PID-001/02 24VPHM-PI-8086 To SLT (TA-0001 / VST-1) PL-8083 VG-8081 16D VG-8086 MP 8082 MZH 8383 NON-ESPN ESPN 24VPHM-PID-001/15 24VPHM-PI-4382 1G VG-8383 PI-8081 D 24VP00 PI-8086 MP 8182 DW 24VPHM S 24VPHM-PID-001/14 24VPHM-PI-8581 C S VG-8184 PL-8183 DN40 PI-8581 DN50 Uncontrolled Once Printed B B SHEET TITLE: 24VPHM-PID-001/06 DIAGRAM TITLE: A 24VPHM-PID-001 NOTES: 1.Fire protection to be applied for whole process system up to isolation valve 2. Bellow sealed gate valves are used on pipelines potentially exposed to tritium. 3. For commissioning/testing (bypass, gas analysis) HYDROGEN MITIGATION SYSTEM OVERFLOW TANK (OFT) PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 6/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 11-B1-01 TCWS Drain Tanks Upper Level VP HM L NON-ESPN ESPN DW 16C S PI-8190 24VPHM-PID-001/15 24VPHM-PI-4390 VG-8392 K From OFT (TA-0606) 16K MTE 8283 LC VG-8190 Note 3 K MTW 8283 PI-8087 24VPHM-PID-001/06 24VPHM-PI-8087 DN150 Process gas inlet N04 MTE 3020 HX-8091 I VG-3395 PI-3505 DN25 Note 3 8192 MAM 8092 MAM 8091 H2 H2 VG-3391 MPD 8291 MZH 3391 MTE 3120 MTW 3120 LC H2 MAM MAM 8191 LO HX-8191 G 24VPHM-PID-001/12 16J 24VPHM-PI-3001 Note 3 DN25 VG-3398 H2 I CHW-H1 train A Note 5 LO DN25 H 24VPHM-PID-001/02 24VPHM-PI-3002 1E LC PINST-8192 Note 5 VG-3392 C01 PINST-8092 MP 3220 J AH AL LL CHW-H1 train A to PST LO Note 3 C02 VR-3390 MTW 3020 LC VG-3396 J AH DN25 PI-3506 C12 Note 5 AH VR-3391 MP 3221 AH AL LL PINST-3391 N01 MZH 3390 DN15 MP 8291 H CHW-H1 train B to PST 1D 24VPHM-PID-001/02 24VPHM-PI-3102 VG-3394 PI-3101 C11 VR-1390 MZL 1390 PI-3507 DN25 Note 5 24VPHM-PID-001/12 24VPHM-PI-3101 G 16G VG-3393 LC VG-3397 MZH 1390 CHW-H1 train B LO Note 3 F F N04 NON-PED/PS 0.5 barg PED/PS-20 barg NON-ESPN ESPN N05 S S DN150/100 Condensate catch pot N02 N03 24VPHM-PID-001/08 24VPHM-PI-1090 DN150 PI-8191 DN150 PI-1190 E Process gas outlet MLL 8091 VG-8092 MTE 8092 MTE 8192 MTH 8091 MTW 8092 MTW 8192 MTW 8091 Note 3 MTH 8191 MP 8292 MTW 8191 MPH 8093 E Note 2 MPH 8193 S S PI-8091 1E DN150/100 To Exhaust Filter (Vault) LC PI-8593 DN150 VG-8091 VG-8191 AH hHX VG-8192 DN150/100 to OFT (TA-0606) DN15 PI-8594 VG-8393 1J D DN40 24VPHM-PID-001/06 24VPHM-PI-8594 D Condensate return S S DN50 PI-8093 NON-ESPN ESPN to DS In DTR S C DN50 DN50 PI-1191 PI-8193 VG-8194 VG-8094 C S 24VPHM-PID-001/10 3G 24VPHM-PI-1091 VG-8193 Safety purge VG-8093 Uncontrolled Once Printed B B SHEET TITLE: A NOTES: 1.Fire protection to be applied for whole process system up to isolation valve 2. Required min. length hHX of vertical pipe section (filled with water) to compensate pressure difference between OFT head space and HX-0008 (water seal) and to allow condensate return to OFT. 3. For commissioning/testing/analysis 4. Bellow sealed gate valves are used on pipelines potentially exposed to tritium 5. This piping is classified as Non-ESPN. 24VPHM-PID-001/07 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM EXHAUST CONDENSER PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 7/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-L1-CNB NB Cell 11-L1-V08 Vertical Shaft V08 11-L2-V08 Vertical Shaft V08 11-L3-02E TCWS Area East 11-L3-03N Upper pipe chase N K K J J LC I DN15 PI-1593 VG-1393 I PI-1519 MPG 0002 DN15 S S HEPA N1 VG-1192 PI-1193 DN150 VG-1193 H H FI-1192 MR 1192 NOTE-4 Y MPG 0001 DN150 G PI-1192 G Note 2 S 1G DN150 F PI-5004 24VPHM-PID-001/07 24VPHM-PI-1090 1D NOTE-4 DN40 PI-1592 DN25 PI-1090 Note 2 Process gas outlet F N4 from Exhaust Condenser (DTR) 24VPHM-PID-001/09 24VPHM-PI-1093 DN15 PI-1516 VG-1093 E To Extraction Pipe (ST-VS) PI-1093 24VPHM-PID-001/13 24VPHM-PI-5004 5B S E PI-1090 DN150 DN150 Note 5 N1 VG-1092 MR 1092 N1 D Y D TA-0607 DUST Collection Tank MPD 1091 MPD 1191 C C Uncontrolled Once Printed B B NOTES: 1.Fire protection to be applied for whole process system up to isolation valve 2. For commissioning/testing/Sampling (filter test)/maintenance (DS ET function) 3. Bellow sealed gate valves are used on pipelines potentially exposed to tritium 4. All piping in this section is classified as Non-ESPN. 5. Minimum 15*D Distance shall be maintained in piping. SHEET TITLE: 24VPHM-PID-001/08 DIAGRAM TITLE: 24VPHM-PID-001 Hydrogen Mitigation System EXHAUST FILTERS A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 8/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-L3-02E TCWS Area East 14-L3-V1 Ventilation Systems Shaft 14-L2-23 Room name IO restricted K K J J I I H H PI-1197 MFT 1091 MFT 1191 Note 2 From exhaust filters 24VPHM-PID-001/08 24VPHM-PI-1093 MPD 1291 HH AH MS 1291 MTW 1291 Note 3 24VPHM 32DTST S Note 4 PI-1195 Note 1,4 VK-1194 VG-1195 PB-1190 G 24.VP-32-001-IP-02 DN150 To DS Train-B DN150 16F MTE 1291 PI-1196 G VC-1397 DN80 S VG-1196 F F 14-L2-V1 Ventilation Systems Shaft DN150 PI-1194 DN150 PI-1093 14-L2-21 Room name IO restricted E E PI-1094 DN80 Note 2 D Note 4 VC-1394 MTE 1292 HH AH MPD 1292 MS 1292 MTW 1292 Note 3 24VPHM 32DTST S PB-1090 PI-1095 24.VP-32-001-IP-03 DN150 To DS Train-A DN150 VG-1095 PI-1096 VK-1093 D S C C VG-1096 Uncontrolled Once Printed B B SHEET TITLE: 24VPHM-PID-001/09 DIAGRAM TITLE: A 24VPHM-PID-001 NOTE: 1. Fire protection to be applied for Complete pipework. 2. Valves set at commissioning and locked in place. 3. Fan changeover initiated by 2 out of 3 from fan flow rate( MFT-2061,MFT-2161), fan speed and fan differential pressure. 4. All piping in this section is classified as Non-ESPN 1 2 HYDROGEN MITIGATION SYSTEM STVS BLOWERS PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 3 DATE OF ISSUE: 16 Sheet N°: 9/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L K K J J 11-B1-01 TCWS Drain Tanks Upper Level I I H H MDS 1098 MDS 1198 MPD 1195 AL LL MPD 1095 AL LL MPH 1096 H MPH 1196 H MPH 1097 H MPH 1197 H 24VPHM 32DT80 PIC N2 purge from Exhaust Condenser G 1B NOTE-2 PI-1091 24VPHM-PID-001/07 24VPHM-PI-1091 G 24.VP-32-001-IP-01 DN50 F F E E D D C C NOTE: 1. Fire protection to be applied for whole process Piping 2. All piping in this section is classified as Non-ESPN Uncontrolled Once Printed B B SHEET TITLE: 24VPHM-PID-001/10 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM DS COLLECTION A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 10/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-B2-02N Basement Gallery N 11-B2M-01N Lower Pipe Chase N 11-B2-01 TCWS Drain Tanks K K J J I I H H S Air To DTR G VG-1158 DN100 PI-1158 NOTE-2 G S PI-1058 Air supply from Vault Air To DTR DN100 VG-1058 DPI-1058 (DN-200) F F Uncontrolled Once Printed TCWS tunnel E E D D C C B B SHEET TITLE: 24VPHM-PID-001/11 DIAGRAM TITLE: 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM A NOTE: 1.Fire protection to be applied for whole process system up to isolation valve 2. All piping in this section is classified as Non-ESPN VAULT AIR SUPPLY LINE PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 11/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels VP HM L 11-B1-01 TCWS Drain Tanks Upper Level 26CHH1-A 24VPHM CHWS train A inlet MTW 3200 MP 3200 P PI-3001 J VG-3303 MTE 3200 VG-3302 K MFT 3200 DN15 K LO To EXC (HX-8091) train A PI-3001 21G MFE-3200 I MP 3240 From PST cooling coil train A MTW 3240 PI-3003 24VPHM-PID-001/02 24VPHM-PI-3003 VG-3306 P CHWS-H1 train A Outlet 26CHH1-B 24VPHM MTW 3201 P DN25 VG-3313 VG-3312 LO MP 3201 H G DN15 G PINST-3101 MTE 3201 MFT 3201 VG-3203 VG-3304 MFE-3040 LC NOTE-2 PI-3503 DN65 H To EXC (HX-8191) train B PI-3101 16G F Note 1 DN65 NOTE-2 F From PST cooling coil train B PI-3103 24VPHM-PID-001/02 24VPHM-PI-3103 MTW 3241 LO VG-3315 24.VP.HM 26.CH.H1B DN15 MP 3241 PINST-3142 MTE 3241 LO MFT 3140 VG-3316 LC CHWS train B inlet MFE-3201 DN25 VG-3211 P E LC VG-3213 DN25 NOTE-2 MFE-3140 CHWS-H1 train B Outlet VG-3314 DN65 PI-3504 24.VP-26.CH-001-IP-04 Note 1 Uncontrolled Once Printed 24VPHM-PID-001/07 24VPHM-PI-3101 VG-3311 PI-3502 24.VP-26.CH-001-IP-03 16D I 24.VP-26.CH-001-IP-02 Note 1 E J 24VPHM 26CHH1-A DN15 MFT 3040 LO MTE 3240 16E 24VPHM-PID-001/07 24VPHM-PI-3001 NOTE-2 PINST-3242 Note 1 VG-3305 DN25 LC VG-3201 DN65 VG-3301 DN65 PI-3501 24.VP-26.CH-001-IP-01 LO 24 PINST-3201 L D D C C B B SHEET TITLE: 24VPHM-PID-001/12 DIAGRAM TITLE: NOTES: 1. CHWS pipework is thermally insulated for cold conservation and fire protection. Vapour barrier provided to avoid condensation at outer pipe walls and risk of condensate accumulation in bund BA-0001 A 2. All piping in this section is classified as Non-ESPN 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM CHWS-H1 NETWORK PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 12/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM 65.11.NG 24.VP.HM N2 supply (VG-1235) 11-B1-01 TCWS Drain Tanks Upper Level L MP 5022 MFT 5022 S 24.VP-65.00.NG-001-IP-11 PIC N2 purge for HMS head space venting (safe state) MFI 5323 DN25 VC-5301 VG-5101 To PST (TA-0601) NOTE-1 PI-5101 1H 24VPHM-PID-001/02 24VPHM-PI-5101 VC-5302 NOTE-2 K K NOTE-1 To OFT drain (TA-0606) PI-5081 1E DN25 J 24VPHM-PID-001/06 24VPHM-PI-5081 J 65.11.NG 24.VP.HM MP 5208 N2 supply (VG-0235) To QEN drain (TA-0603) NOTE-1 PI-5071 1D 24.VP-65.00.NG-001-IP-10 DN25 VG-5201 24VPHM-PID-001/04 24VPHM-PI-5071 I I To PST drain (TA-0601) NOTE-1 PI-5055 1D H DN25 H G G F F E E D D C C 11-L3-02E TCWS Area East MP 5005 65.11.NG 24.VP.HM N2 supply (VG-0237) PI-5004 13F DN25 VG-5004 65.11.NG 24.VP.HM N2 supply (VG-0237) DN25 VK-5004 S 24VPHM-PID-001/08 24VPHM-PI-5004 B To Filters (FI-0001/-0002) DN25 B S PI-5004 PI-5104 24.VP-65.00.NG-001-IP-14 Uncontrolled Once Printed 24VPHM-PID-001/02 24VPHM-PI-5055 SHEET TITLE: NOTE-1 24VPHM-PID-001/13 DIAGRAM TITLE: 24VPHM-PID-001 24.VP-65.00.NG-001-IP-15 VG-5104 HYDROGEN MITIGATION SYSTEM VK-5104 NITROGEN DISTRIBUTION A NOTES: PBS NODE: 1. All piping in this section is classified as Non-ESPN 2. Needle valve & rotameter combines to form complete rotameter assembly. 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 13/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-B2-01 TCWS Drain Tanks K K J J I I H H From Drainage Distribution, VST 16F PI-8542 24VP00-PID-001/10 24VP00-PI-8542 DN65 G G From HMS bund (BA-000, Refer Drawing 24VPHM-PID-001/02) F 24VP00 F 24VPHM 24VPHM PI-8596 26DR00 DRS draining 24.VP-26.DR-001-IP-02 DN65 From PST (TA-0601) 16C E PI-8551 24VPHM-PID-001/02 24VPHM-PI-8551 From OFT (TA-0606) 16C D DN65/50 PI-8581 24VPHM-PID-001/06 24VPHM-PI-8581 PI-8595 DN65 DN50 D From QEN (TA-0603) 16C E DN65 PI-8571 24VPHM-PID-001/04 24VPHM-PI-8571 DN65 C C B B Uncontrolled Once Printed NOTES: 1. Bellow sealed gate valves are used on pipelines potentially exposed to tritium SHEET TITLE: 24VPHM-PID-001/14 DIAGRAM TITLE: 24VPHM-PID-001 Hydrogen Mitigation System Drainage Distributaion Network A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 14/16 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L 11-B1-01 TCWS Drain Tanks Upper Level K K J J I I To PAR for cleaning LP PI-4360 24VPHM-PID-001/03 24VPHM-PI-4360 1J DN40 H VG-4353 To PST drain LP PI-4356 MFT 4221 6500DW 24VPHM MP 4221 DN40 HMS DW Interface Point PI-4301 PI-4301 DN80 DN80 VG-4352 Manual Addition of additives NOTE-1 S LP To PST for Filling / cleaning PI-4351 24VPHM-PID-001/02 24VPHM-PI-4351 1L 24.VP-65.00.DW-001-IP-18 VG-0124 VK-4301 VG-4001 H 24VPHM-PID-001/02 24VPHM-PI-4356 1C EJ-4301 NOTE-2 DN80/50 DN50 VG-4351 G G Manual Addition of additives S To QEN drain LP PI-4308 PI-4372 1C DN80 VG-4002 EJ-4302 NOTE-2 DN40 VG-4371 DN80/40 F 1J DN40 24VPHM-PID-001/04 24VPHM-PI-4370 VG-4372 To OFT for cleaning LP PI-4380 E F To QEN for filling / cleaning LP PI-4370 24VPHM-PID-001/04 24VPHM-PI-4372 1K DN40 24VPHM-PID-001/06 24VPHM-PI-4380 E VG-4381 To OFT drain LP PI-4382 1D DN40 24VPHM-PID-001/06 24VPHM-PI-4382 VG-4382 D D To WRC for cleaning LP PI-4375 1J DN40 VG-4373 To EXC for cleaning LP PI-4390 1K C DN40 11-L3-02E TCWS Area East 24VPHM-PID-001/05 24VPHM-PI-4375 24VPHM-PID-001/07 24VPHM-PI-4390 C VG-4391 11-L1-CNB NB Cell 6500DW 6500DW 24VPHM NOTE-1 24.VP-65.00.DW-001-IP-20 24.VP-65.00.DW-001-IP-24 VG-0126 B VG-4292 NOTE-1 PI-4303 Connection For L3 ( Filters) PI-4392 24VPHM DN25 DN25 VG-0123 B Uncontrolled Once Printed PI-4304 24.VP-65.00.DW-001-IP-21 SHEET TITLE: DN25 24VPHM-PID-001/15 DIAGRAM TITLE: VG-0125 24VPHM-PID-001 HYDROGEN MITIGATION SYSTEM A DEMINERALISED WATER DISTRIBUTION NOTES: 1. All piping in this section is classified as Non-ESPN 2. Scheme of additive addition is tentative & shall be developed in later stage. PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 15/16 1.13 17 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PBS 3 levels L 24 VP HM L K K 11-B1-01 TCWS Drain Tanks Upper Level NOTE-1 65.11.CA-SB 24.VP To CA train B solenoid valve boxes PI-2101 J -- 24.VP-65.00.CA-001-IP-03 DN20 Not Connected - J Compressed Air train B (PIC-CA) (Tap of point on DTR North wall near HMS) I I 65.11.CA-SA 24.VP To CA train A solenoid valve boxes PI-2001 -- 24.VP-65.00.CA-001-IP-02 DN20 Not Connected - Compressed Air train A (PIC-CA) (Tap of point on DTR west wall near HMS) H H G G 65.11.CA-NS 24.VP To CA non-PIC solenoid valve boxes PI-2301 -- 24.VP-65.00.CA-001-IP-01 DN20 Not Connected - Non-PIC CA (Tap of point on DTR north wall near HMS, VG-0640) F F E E 11-L3-02E TCWS Area East NOTE-1 65.11.CA 24.VP Compressed Air SIC D P 24.VP-65.00.CA-001-IP-XX Connection for Filters in L3 DN20 Compressed Air SIC VG-2202 PI-2003 DN20 65.11.CA 24.VP 24.VP-65.00.CA-001-IP-X D PI-2002 PI-2102 To Solenoid valves To Solenoid valves DN20 C C NOTES: 1. All piping in this section is classified as Non-ESPN Uncontrolled Once Printed B B SHEET TITLE: 24VPHM-PID-001/16 DIAGRAM TITLE: 24VPHM-PID-001 Hydrogen Mitigation System Compressed Air distribution A PBS NODE: 24VPHM IO REFERENCE: DOCUMENT TYPE: PID 2 3 4 5 6 7 8 9 10 11 12 13 14 Sep-2023 DESGIN AGENCY DOCUMENT Sheet Size: STATUS: VERSION: --E __ 15 A1 __ EXTERNAL REFERENCE: 5PVPZU 1 DATE OF ISSUE: 16 Sheet N°: 16/16 17 A