内部公开▲ AIGS Antenna Configuration on EMS This gurid book fit for where has AIGS antenna . 1. 2. Find the site which has AIGS on EMS , right click the OMMB and start NE Configuration After finish start NE , right click the OMMB , open AIGS Device Management and Configuration Management . 3. Find the site in Configuration Management . 4. After find the site , go Modify Area > Managed > Element > Device > RRU(which include the AISG site ) > Power Outlet Set , double click . <以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第1页 内部公开▲ 5. Modify the Switch status to “AISG R8485[1]” and Voltage “220[1]”,then save. 6. Then go Modify Area > Managed > Element > Device > BTS Auxiliary Peripheral Device > Antenna Entity Object , build a new object. 7. Input the information of AISG Antenna , then save <以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第2页 内部公开▲ 8. 9. Synchronize all data which modified. Find site in AIGS Device Management. 10. Scan the AISG antenna . This step will spend some time , please wait until the result appear. Word in Detailed information is scan result , if this site has AISG antenna , result count is 1 . 11. Click the detail information blew the window , then click the green plus button . change the connected antenna entity ID to 1. <以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第3页 内部公开▲ 12. Synchronize all data which modified. 13. Back to Configuration Management . go Modify Area > Managed > Element > Device > BTS Auxiliary Peripheral Device > Antenna Attribute Object . change the Antenna gain , Antenna gap (mm) , number of antenna unit according to custom requirements . <以上所有信息均为中兴通讯股份有限公司所有,不得外传> 第4页