ASHRAE PSYCHROMETRIC CHART NO.1 55 STATE POINT & PROCESS REPORT NORMAL TEMPERATURE BAROMETRIC PRESSURE: 29.907 INCHES OF MERCURY R Copyright 1992 AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS, INC. 1 3 F E E T 50 13 FEET ∞ 1.0 -∞ 1.0 AOT_ Clinic upgrade 90 Additional 30kW heater LAT = 12C, 96%RH Air flow 10,300 CFM .028 .026 -2000 -1000 5000 2.0 0.6 SENSIBLE HEAT TOTAL HEAT 3000 0.5 4.0 8.0 -∞ -48.0.0 -2.0 Qs Qt 0.4 45 85 WE T 0 0 200 0.2 0.1 -0.1 -0.2 15 00 0 5 -0. .4 -0 -0.3 0.3 -1. 0 80 50 0 40 BU LB TEM PE RA TU RE - .024 55 °F .022 80 1000 ENTHALPY HUMIDITY RATIO ∆h ∆W .020 75 35 OA 50 .018 5 14. F 30 O TI RA U T SA 25 N M TE R PE 70 .014 RA 60 ER T. P U.F E-Heater % 70 Fan Heat C EUM OL 0V 14. Mix % 80 55 % 2005 Recommended WINTER . LB 60 50 50% 45 40% 40 Class A1 30% 0 13. 35 AIR 40 Y DR 5 13. COMFORT 45 35 .016 65 LAT 15 70 % 90 55 50 - 65 60 20 E UR AT °F 20% 12. 10 15 20 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 5 E HUMIDITY 10% RELATIV C:\Users\Banch\Documents\AOT\AOT_9000.hdd HUMIDITY RATIO - POUNDS MOISTURE PER POUND DRY AIR PO O 75 R AI .012 .010 40 .008 .006 35 .004 25 ENTHALPY - BTU PER POUND OF DRY AIR File Not Saved C:\Users\Banch\Documents\AOT\AOT_9000.hdd 45 .002 115 - U BT R PE D UN Y DR DRY BULB TEMPERATURE - °F PY AL H T EN 35 60 85 0.8 120 R 60 30 SYSTEM FLOW DIAGRAM - STATE POINT & PROCESS REPORT Prepared By: Bancha S Company: BANTIPAT LP Phone: 089-7448534 Fax: email: Service@bantipat.com Report Date: Monday, October 02, 2023 Project Information: AOT_ Clinic upgrade Additional 30kW heater LAT = 12C, 96%RH Air flow 10,300 CFM Altitude: 13 (Feet) Barometric Pressure: 29.907 (in.Hg) Atmospheric Pressure: 14.689 (psia) RA OA Air Flow 9,001 cfm DryBulb 75.2 °F WetBulb 62.7 °F RH 50.0 % Humidity 65.4 gr/lb Enthalpy 28.3 Btu/lb Dewpoint 55.3 °F Air Flow 1,299 (cfm) DryBulb 96.5 °F WetBulb 79.8 °F RH 48.8 % Humidity 127.7 gr/lb Enthalpy 43.3 Btu/lb Dewpoint 74.1 °F Mix LAT Fan Heat E-Heater Air Flow 10,300 cfm DryBulb 77.9 °F WetBulb 65.3 °F RH 51.1 % Humidity 73.3 gr/lb Enthalpy 30.2 Btu/lb Dewpoint 58.4 °F Air Flow 10,300 cfm DryBulb 53.6 °F WetBulb 53.0 °F RH 96.0 % Humidity 58.9 gr/lb Enthalpy 22.0 Btu/lb Dewpoint 52.5 °F Air Flow 10,300 cfm DryBulb 55.4 °F WetBulb 53.7 °F RH 89.9 % Humidity 58.9 gr/lb Enthalpy 22.4 Btu/lb Dewpoint 52.5 °F Air Flow 10,300 cfm DryBulb 64.4 °F WetBulb 57.3 °F RH 65.2 % Humidity 58.9 gr/lb Enthalpy 24.6 Btu/lb Dewpoint 52.5 °F Total Energy -378,930 Btu/hr Total Energy 20,334 Btu/hr Total Energy 101,672 Btu/hr Sensible Energy -274,790 Btu/hr Sensible Energy 20,334 Btu/hr Sensible Energy 101,672 Btu/hr Latent Energy -104,140 Btu/hr Latent Energy 0 Btu/hr Latent Energy 0 Btu/hr Sensible Heat Ratio 0.725 Sensible Heat Ratio 1.000 Sensible Heat Ratio 1.000 Moisture Difference -95.1 lb/hr -11.4 gal/hr Moisture Difference 0.0 lb/hr 0.0 gal/hr Moisture Difference 0.0 lb/hr 0.0 gal/hr C:\Users\Banch\Documents\AOT\AOT_9000.hdd Version 7.9.8 Page 1 STATE POINT & PROCESS REPORT Report Date: Monday, October 02, 2023 Project Information: AOT_ Clinic upgrade Additional 30kW heater LAT = 12C, 96%RH Air flow 10,300 CFM Altitude: 13 (Feet) 1. OA Barometric Pressure: 29.907 (in.Hg) Atmospheric Pressure: 14.689 (psia) STATE POINT DATA Air Flow (Standard) (cfm) 1,299 Prepared By: Bancha S Company: BANTIPAT LP Phone: 089-7448534 Fax: email: Service@bantipat.com Dry Bulb (°F) 96.499 Wet Bulb (°F) 79.800 Relative Humidity (%) 48.8 Humidity Ratio (lb/lb) 0.01824 Specific Volume (cu.ft./lb) 14.433 Enthalpy Dry Bulb (°F) 75.200 Wet Bulb (°F) 62.701 Relative Humidity (%) 50.0 Humidity Ratio (lb/lb) 0.00934 Specific Volume (cu.ft./lb) 13.688 Enthalpy Dry Bulb (°F) 77.924 Wet Bulb (°F) 65.259 Relative Humidity (%) 51.1 Humidity Ratio (lb/lb) 0.01046 Specific Volume (cu.ft./lb) 13.782 Enthalpy Air Flow Standard (cfm) 1,299 Dry Bulb (°F) 96.5 Humidity Ratio (lb/lb) 0.01824 Wet Bulb (°F) 52.955 Relative Humidity (%) 96.0 Humidity Ratio (lb/lb) 0.00841 Specific Volume (cu.ft./lb) 13.116 Total Cooling (tons) -31.6 Total Energy (Btu/hr) -378,930 Sensible Energy (Btu/hr) -274,790 Latent Energy (Btu/hr) -104,140 Wet Bulb (°F) 53.703 Relative Humidity (%) 89.9 Humidity Ratio (lb/lb) 0.00841 Specific Volume (cu.ft./lb) 13.162 Total Heating (tons) 1.7 Total Energy (Btu/hr) 20,334 Sensible Energy (Btu/hr) 20,334 Latent Energy (Btu/hr) 0 Wet Bulb (°F) 57.288 Relative Humidity (%) 65.2 Humidity Ratio (lb/lb) 0.00841 Specific Volume (cu.ft./lb) 13.392 Total Heating (tons) 8.5 Total Energy (Btu/hr) 101,672 Sensible Energy (Btu/hr) 101,672 Latent Energy (Btu/hr) 0 Dew Point (°F) 74.060 (Btu/lb) 43.296 Density Vapor Pressure (in.Hg) 0.8485 Absolute Humidity (gr/cu.ft.) 8.847 Vapor Pressure (in.Hg) 0.4407 Absolute Humidity (gr/cu.ft.) 4.778 (lb/cu.ft.) 0.0733 Vapor Pressure (in.Hg) 0.4929 Absolute Humidity (gr/cu.ft.) 5.315 Air Flow Standard (cfm) 9,001 Dry Bulb (°F) 75.2 Humidity Ratio (lb/lb) 0.00934 Density Vapor Pressure (in.Hg) 0.3975 Absolute Humidity (gr/cu.ft.) 4.490 (lb/cu.ft.) 0.0705 2. RA STATE POINT DATA Air Flow (Standard) (cfm) 9,001 Dew Point (°F) 55.300 (Btu/lb) 28.272 Density (lb/cu.ft.) 0.0737 3. Mix STATE POINT DATA Air Flow (Standard) (cfm) 10,300 Process: Air Mixing State Point No. 1 Name OA Dew Point (°F) 58.400 (Btu/lb) 30.167 State Point No. 2 Name RA Density 4. LAT STATE POINT DATA Air Flow (Standard) (cfm) 10,300 Dry Bulb (°F) 53.600 Enthalpy Dew Point (°F) 52.480 (Btu/lb) 21.991 (lb/cu.ft.) 0.0769 Process: Cooling Coil Start Point Name Mix Dehumidification Sensible Heat Ratio (lb/hr) -95.1 0.725 Enthalpy/ Humidity Ratio (Btu/lb / lb/lb) 3,986 5. Fan Heat STATE POINT DATA Air Flow (Standard) (cfm) 10,300 Dry Bulb (°F) 55.400 Enthalpy (Btu/lb) 22.430 Dew Point (°F) 52.480 Density (lb/cu.ft.) 0.0766 Vapor Pressure (in.Hg) 0.3975 Absolute Humidity (gr/cu.ft.) 4.475 Process: Sensible Heating Start Point Name LAT Moisture Difference (lb/hr) 0.0 Sensible Heat Ratio 1.000 Enthalpy/ Humidity Ratio (Btu/lb / lb/lb) N/A 6. E-Heater STATE POINT DATA Air Flow (Standard) (cfm) 10,300 Dry Bulb (°F) 64.400 Enthalpy (Btu/lb) 24.624 Dew Point (°F) 52.480 Density (lb/cu.ft.) 0.0753 Vapor Pressure (in.Hg) 0.3975 Absolute Humidity (gr/cu.ft.) 4.398 Process: Sensible Heating Start Point Name Fan Heat Moisture Difference (lb/hr) 0.0 Sensible Heat Ratio 1.000 Enthalpy/ Humidity Ratio (Btu/lb / lb/lb) N/A C:\Users\Banch\Documents\AOT\AOT_9000.hdd Version 7.9.8 Page 3