CALYPSO F
INFOTEC
Multifunctional Radiological RAD system with manual movements (AFM)
MULTIFUNCTIONAL RADIOLOGICAL DR SYSTEM
SYSTEM DISTINCTIVENESS


N

Simple and efficient system with manual movement
User-friendly and intuitive operator interface
F
Low doses in all applications
High image quality
MAIN FEATURES





2
X-ray assembly column stand, patient table top and wall stand with manual movements
Innovative system console completely integrated
Digital image acquisition system with fixed or Wi Fi detectors
Full DICOM functionality
High frequency generator
INFOTEC
Calypso F (AFM) is the multifunctional DR system of the
Calypso line configured with X-ray assembly column
stand, table with fixed or adjustable height and wall
stand with tilting or vertical movement.
The system is completed with the digital system
OPERA D4000RAD and the generator OPERA G serie
DR.
The OPERA D4000RAD is an X-ray images acquisition
system that can be combined with Wi-Fi or fixed detector.
o
Automatic acquisition and processing provide images ready
for diagnosis.
Complete DICOM functions allows to communicate easily to
RIS-PACS systems.
The OPERA G series DR generator is high frequency with
command integrated in the console.
INTENDED USE
This equipment is design for performing general
radiography
APPLICATIONS AND TECHNIQUES
Emergency care
General diagnostics
Skeletal and Thoracic Radiography Examination
3
AVAILABLE CONFIGURATIONS
Column X-ray assembly with fixed height table and wall stand
Column X-ray assembly with variable height table and wall stand
4
Column X ray assembly and wall bucky
INFOTEC
TECHNICAL FEATURES
FLOOR COLUMN STAND
(D)
Type
Column floor stand height
Rails length
Longitudinal travel (column)
Transverse execution (x-ray assembly)
Longitudinal movement type (column)
Vertical travel (x ray assembly)
Minimum floor/focus distance (X ray assembly)
Balancing technique (x ray assembly)
Vertical movement type (x ray assembly)
Column rotation angle on vertical axis
Movement type column rotation
V
Rotation angle around horizontal axis (xray assembly)
Horizontal rotation movement type
(x-ray assembly)
Brakes type
CONTROL PANEL
Focus/film indication
Indicator of X-ray beam
manual
239,5 cm
254 cm
200 cm
± 11 cm (optional)
Manual
148,4 cm
48,5 cm
counterweight
Manual (standard) and motorized (optional)
± 90°
Manual, with pedal, stops every 90°
(Side x-rays with lateral cassette support .
Exams on stretcher with Wi-Fi detector)
+180° -150°
T
Manual, with stops every 90°
Electromagnetic for all movements
Fixed height table: centimetres scale
Variable height table : display
Goniometer
Control panel with mechanical keys
Unlock of all the manual movements and of the
floor stand assembly
Keys for column stand motorized movement and
elevating table
MANUAL OR MOTORIZED RECTANGULAR FIELD COLLIMATOR (OPTIONAL)
Control type
Manual
U
Automatic
Image receptor alignment
Laser pointer
Light field simulating X-ray field
Power LED
Optional filters
1 mm Al + 0,1 mm Cu
(manual or motorized filters insertion in
1 mm Al + 0,2 mm Cu
function of the installed collimator )
2 mm Al
Collimator rotation
±90° (standard with automatic collimator , optional
with manual collimator)
5
ELEVABLE PATIENT TABLE-TOP
Manual bucky for Wi-Fi detector, any size (max 43x43cm)
Bucky size sensing for any Wi Fi detector size (max 43x43cm)
Fixed detector support
Plastic laminate standard
Patient table-top
Carbon fiber optional
0,9 mm Al eq plastic laminate
Attenuation
0,5 mm Al eq carbon fiber
y 220 x 80 cm (standard)
Dimension
240 x 80 cm (optional only with carbone fiber table-top)
81 cm (±40,5 cm) table-top length 220 cm
Longitudinal travel
101 cm (±50,5 cm) table-top length 220 cm
26 cm (±13 cm)
Transversal travel
Manual with foot pedal control
Patient table-top movement type
53,5 cm – 85,5 cm (with manual or automatic bucky)
Vertical excursion
55 cm – 87 cm (with fixed detector)
Motorized
Vertical movement type
z
Maximum patient weight
270 kg (without limitations)
330 kg (with limitations, static exams)
(patient lying on the examination table)
57 cm (manual or automatic bucky)
Bucky longitudinal excursion
61 cm (with fixed detector)
Manual or motorized
Bucky movement type
Electromagnetics
Brakes type
FIXED PATIENT TABLE-TOP
Potter type
6
Potter type
Patient table-top
Absorption
Dimension
Longitudinal travel
X
Transversal travel
Patient table top movement type
Patient table-top floor distance
Maximum patient weight
(patient lying on the examination table)
Bucky longitudinal excursion
Bucky movement type
Manual bucky for Wi-Fi detector, any size (max 43x43cm)
Bucky size sensing for any detector size (max 43x43cm)
Fixed detector support
plastic laminate (standard)
carbon fibre: (optional)
0,9 mm Al eq (plastic laminate)
0,5 mm Al eq (carbone fiber)
220 x 80 cm (standard)
240 x 80 cm (optional carbone fiber table top)
81 cm (±40,5 cm) with table top of 220 cm
101 cm (±50,5 cm) with table top of 240 cm
26 cm (±13 cm)
Manual with pedals brake release
75,7 cm (with manual or automatic bucky)
77,2 cm (fixed detector)
270 kg (without limitations)
330 kg (with limitations, static exams)
57 cm (with manual or automatic bucky)
61 cm (with fixed detector)
Manual
INFOTEC
WALL STAND WITH TILTING BUCKY
Potter type
Column height
Minimum distance from detector center to the floor
Maximum distance from detector center to the floor
Vertical travel
Vertical movement type
Potter tilting
Movement type and tilting
Potter rotation
Rotation movement type
Brakes type
WALL STAND WITH VERTICAL BUCKY
Manual bucky for detector with any dimension (max 43x43cm)
Bucky size sensing of detector size for any detector dimensions
(max 43x43cm)
Fixed detector support
230,4 cm (with manual or automatic bucky)
239,4 cm (with fixed detector)
45,4 cm (with manual or automatic bucky)
42,4 cm (with fixed detector)
185,8 cm (with automatic or manual bucky)
182,8 cm (with fixed detector)
140,4 cm
Manual (standard) or motorized (option)
+90° / -20°
Manual (standard) and motorized (optional)
+90°
Manual
Electromagnetics
7
Potter type
Column height
w
Minimum distance from detector
center to the floor
Maximum distance from detector
center to the floor
Vertical travel
Vertical movement type
Brakes type
ANTISCATTER GRID
Patient table-top
Wall stand
Manual bucky for detector with any dimension (max 43x43cm)
Bucky size sensing of detector size for any detector dimensions
(max 43x43cm)
Fixed detector support
230,4 cm (with manual vertical movement)
239,4 cm (with motorized vertical movement)
42 cm (with manual or automatic bucky)
36 cm (with fixed detector)
199,4 cm (with automatic or manual bucky)
193,4 cm (with fixed detector)
157,4 cm
Manual (standard) and motorized (optional)
Electromagnetics
With manual bucky or automatic
230 L/inch; 12:1; SID 110 cm
110 L/inch; 12:1; SID 120 cm
103 L/inch; 12:1; SID 100 cm
230 L/inch; 12:1; SID 110 cm
230 L/inch; 12:1; SID 150 cm
230 L/inch; 12:1; SID 180 cm
103 L/inch; 12:1; SID 180 cm
With fixed detector
215 L/inch; 12:1; SID 120 cm
215 L/inch; 12:1; SID 180 cm
215 L/inch; 12:1; SID 155 cm
215 L/inch; 12:1; SID 120 cm
OPERA D4000 RAD DIGITAL SYSTEM (PVR-PTH versions)
DIGITAL PROCESSOR
Composition
Digital image processor unit
Main controller for general system management
Mini tower PC with keyboard and mouse
CPU
Intel i3 (standard)
Intel i7 (option )
Storage capacities
4 GB
8 GB
(A)
16 GB
Operative system
Microsoft Windows 10
Images archive
250 GB (about 10.000 images) expandable up to 2 TB
UPS optional
1300 VA
DETECTORS: OPERA D4000RAD-PVR (VAREX)
Fixed detector
Varex 4343R v3
Wi-Fi detector
LUMEN 4336W
Varex 4343W
LUMEN 2530W
POSSIBLE DETECTORS COMBINATIONS
The maximum operational flexibility of configurable detectors allows various combinations. The system offers
the possibility to share a single Wi Fi detector with different configurations.
8
It is recommended to always associate Csi Premium with Csi Premium and Csi Standard with Csi Standard.
FIXED DETECTOR VAREX
4343R v3
Technology
Amorphous silicon
Scintillator
CsI
Nominal size
43 x 43 cm
Pixel matrix
3072 x 3072 (42.7 x 42.7 cm)
Pixel pitch
139 μm
Spatial resolution
3,6 lp/mm
A/D conversion
16 bit
DQE @ 0 lp/mm
78%
MTF @ 1 lp/mm
56%
Time image preview
1.1 s
Time definitive image
Wi-Fi DETECTOR VAREX
Technology
Scintillator
Nominal size
Pixel matrix
Pixel pitch
Spatial resolution
A/D conversion
DQE@ 0 lp/mm
MTF@ 1 lp/mm
Weight (without battery)
Battery weight
Battery life
Time image preview
Time definitive image
Maximum load uniform loaded over
the entire surface
IP protection degree
2.4 s
LUMEN 4336W
(4336W-G5 C Premium)
(4336W-G5 C Standard)
Amorphous silicon
CsI Standard
CsI-Premium
35 x 43 cm
3072 x 2476 pixel (34.4 x 42.7 cm)
139 µm
3.6 lp/mm
16 bit
Q
64%
74%
65%
61%
2.8 kg
340 g
1600 images over 8 hours
<3s
< 4,1 s
300 kg
IP68
INFOTEC
Wi Fi DETECTOR VAREX
Technology
Scintillator
Nominal size
Pixel matrix
Pixel pitch
Spatial resolution
A/D conversion
DQE @ 0 lp/mm
MTF @ 1 lp/mm
Weight (without battery)
Battery weight
Battery life
Time image preview
Time definitive image
Maximum load uniform loaded over the
entire surface
IP protection degree
Wi-Fi DETECTOR VAREX
Technology
Scintillator
Nominal size
Pixel matrix
Pixel pitch
Spatial resolution
A/D conversion
DQE@ 0 lp/mm
MTF@ 1 lp/mm
Weight (without battery)
Battery weight
Battery life
Time image preview
Time definitive image
Maximum load uniform loaded
over the entire surface
IP protection degree
4343W
Amorphous silicon
CsI Standard
CsI Premium
43 x 43 cm
3072 x 3072 pixel (42.7 x 42.7 cm)
139 μm
3.6 lp/mm
16 bit
65%
76%
61%
57%
3,3 kg
340 g
1600 images over 8 hours
<3s
<5s
300 kg
IP68
LUMEN 2530W
(2530W-G5 Premium)
(2530W-G5 standard)
Amorphous silicon
CsI Standard
CsI Premium
25 x 30 cm
1900 x 2304 pixel (24.9 x 30.2 cm)
131 µm
3.8 lp/mm
16 bit
64%
74%
65%
61%
1,9 kg
340 g
1600 images over 8 hours
<3s
< 3.4 s
300 kg
IP68
9
DETECTORS: OPERA D4000RAD-PTH
Fixed detector
Wi-Fi detector
10
FIXED DETECTOR ThalesTechnology
Scintillator
Nominal size
Pixel matrix
Pixel pitch
A/D conversion
Spatial resolution
DQE @ 0 lp/mm
MTF @ 1 lp/mm
Time image preview
Time definitive image
Wi-Fi DETECTOR ThalesTechnology
Scintillator
Nominal size
Pixel matrix
Pixel pitch
Spatial resolution
A/D conversion
DQE @ 0 lp/mm
MTF @ 1 lp/mm
Weight (without battery)
Battery weight
Battery life
Time image preview
Full image
Maximum load uniform loaded
over the entire surface
IP protection degree
Thales- Pixium RAD 4343 C-E
Thales-Pixium 3543 EZ
Thales-Pixium 2430 EZ
PIXIUM RAD 4343 C-E
Amorphous silicon
CsI
43 x 43 cm
2880 x 2880
148 μm
16 bit
3.4 lp/mm
65%
61%
3s
<5s
PIXIUM 3543 EZ
2430EZ
Amorphous silicon
CsI
35x43 cm
24x30 cm
2400 x 2880
1560 x 1920
148 μm
3.4 lp/mm
16 bit
70%
61%
2.6 kg
1.4 kg
227 g
1050 images @ 20 s/cycle for 8 hours
1s
1s
˂6s
˂4s
300 kg
IP43
INFOTEC
FEATURES
Anatomical programs
E
Automatic exposures
H
Detectors combination
Exams documentations
management
(K)
Real time post processing function
(J)
ATH: Anatomic Tissue Harmonization
Post-processing function
Library of up to 99 parts of the body, each one with 99 projections performed with four different patient types and for a total 39,204 ways of
using the system.
The exposure parameters (kV, mA automatic exposure meter fields) and
the irradiated area can be changed by the operator during the
examination.
Automatic exposure meter completed with measure chamber at three
fields. Each field can be independently selected by the operator or by
the anatomical programming.
Ability to link a predefined dose to each single anatomical program in
function of the patient size.
Generator automatic kV and mA set values. Exposures times fixed by
the automatic exposure meter for constantly maintaining operator preset dose based on the exam type selection.
Exposure index (EI) and deviation index (DI) display.
Registration of the single detector or of two detectors of the same
brand. Can be selected indifferently any combination of two Wi-Fi
and/or fixed detectors
Each acquired image has indicated:
- Patient name
- Label number N°
- Born date
- Date and time of the exam execution
- Institute name
- Radiographic parameters
- Dose (mGy cm2)
- Display images parameters and reference scale
Archives querying and sorting by exam date or by patient name.
Possibility to define the default output (Printers, CD/DVD writer/burner, workstation or PACS). Monitor reporting of the exam submission to PACS or printer.
Management of multiple connected printers and optimization of the
film use with different modes of playback of the captured images (Film
Editor).
Automatic image processing and display optimization through software
algorithms specifically designed for each type of examination.
Real-time display in preview format. At the capture end the images are
automatically displayed in the final format. Application of post- processing algorithms without alteration of the source data that can be restored immediately.
Real-time radiographic images processing software (ATH) for acquired
images enhancement with contrast increasing, brightness and noise reduction. Expansion of the dynamic range.
Parameters can be set in the anatomical programs and can be
customized during installation according to the specific needs of the
operator
- Single image display or multi-image (4, 9, 16) simultaneously
displayed
- Automatic contrast and brightness adjustment
- Window Level and gamma adjustment
- Zoom/Lens with variable enlargement from 1 to 3
- Grey scale inversion
- H&V image reverse
- 90° Image rotation
- SHARP (edges) and SMOOTH (faded edges) spatial filters; kernel size and weight of the applied filter
11
Electronic shutters
Text and marker overlay
Graphic calculation of angles and distances (mm/pixel)
Grid overlay
COBB angle and orthopaedic measurement (option)
Image export in RAW, JPEG and MP4
Reject analysis (flag the image currently shown as rejected
and then specify the reason for its rejection)
MANUAL STITCHING
The stitching with manual acquisition (manual stitching) allows to obtain a single image starting from2 or 3 images component made on table and up to 4 images made on wall bucky. The images are acquired
individually by the operator detector and the X ray assembly manual
positioning.
DICOM service:
- DICOM Store (Send)
- DICOM Storage Commitment
- DICOM Print class
- DICOM Query/Retrieve (optional)
- DICOM Worklist
- DICOM DOSE SR
- DICOM MPPS
- DICOM Media interchange (CD/DVD)
-
Special optional procedure
(p)
DICOM connectivity
(c)
12
INFOTEC
OPERATOR INTERFACE
COMPOSITION
Digital system monitor
Mini-console for on/off generator switch and X-ray button control
DIGITAL SYSTEM MONITOR
Features
Functions
-
G
Multi-touch LCD 23” colour monitor back light
LED for medical use
(B)
Native resolution: 1920 x 1080 pixel (2 MP)
Brightness: 260 nit
Contrast: 1000:1
- Examination type management
- Generator parameters
- Image display
- Image post-processing
- Image management
- Patient data management
- Communication with RIS-PACS, printers, burners.
X-RAY TUBES (possibility to use different X-ray tubes)
RTM782
Anode speed
Anode material
Anode diameter (mm)
Anode angle (°)
Nominal X-ray tube voltage (kV)
Focal spot (mm)
Nominal anode input power,
High speed (kW)
Nominal anode input power,
Low speed (kW)
Maximum heat content
Maximum continuous heat dissipation
Housing specifications
Maximum housing heat content
RT-TZM
73
12,5
150
0.6/1.2
32/78
20/50
225 kJ
(300 kHU)
60 KHU/min
(750 W)
C52
1280kJ
RTM90
RTM101
Low speed/High speed
RT-TZM
RT-TZM
90
102
12,5
12,5
150
150
0.6/1.2
0.6/1.2
35/85
40/100
24/60
225 kJ
(300 kHU)
60 kHU/min
(750 W)
26/63
RTC600
RT-TZM-C
102
13
150
0.6/1.2
43/100
24/63
300 kJ
450 kJ
(400 kHU)
(600 kHU)
80 kHU/min
125 kHU/min
(1000 W)
(1500 W)
C100
1500kJ
13
OPERA G GENERATOR
14
R
GENERAL FEATURES
Work frequency
Up to 450 kHz
High voltage ripple
<1 kV @ 110 kV
Connectable tubes
One tube
MODELS
G400DR
G500DR
G650DR
Power (kW)
40
50
65
80 kV
500 mA
630 mA
800 mA
Current
400 mA
500 mA
630 mA
100 kV
range
--320 mA
400 mA
150 kV
AVAILABLE VERSIONE
G400DR
G500DR
G650DR
LSS =Low speed starter/ DSS =Dual speed Starter
LSS
LSS
DSS
Single phase
Three phase
Three phase
208 VAC (-5%)
208 VAC (-5%)
400 VAC (+10%)
Up to -230 VAC
Up to -230 VAC (+10%)
(AEC)
(+10%)
(opt. AEC)
(opt. AEC)
Input phase/voltage
LSS
Three phase
400 VAC (±10%)
(opt. AEC)
DSS
Three phase
400 VAC (±10%) (AEC)
RADIOGRAPHY
G400DR
G500DR
G650DR
KV range (in 1 kV
40 – 125
40 – 150
40 – 150
steps )
mA range (Rénard
10 – 500
10 – 630
10 – 800
R’10)
mAs range (Rénard se0,1 – 500
0,1 – 630
0,1 – 800
ries R’10)
Exposure time range
1 – 6300 ms
DOSE AREA PRODUCT (DAP)
Measure device
Ionization chamber at the collimator out put
Radiography data
DAP (mGy*cm2 or μGy*m2) and AK (mGy)
Data display
On the control monitor and on the images
MESSAGES ERRORS
In case of generator malfunction the dedicated display reports error message with its code
G800DR
80
1000 mA
800 mA
500 mA
G800DR
DSS
Three phase
400 VAC (+10%)
(AEC)
G800DR
40 – 150
10 – 1000
0,1 – 1000
INFOTEC
ACCESSORIES
PATIENT TABLE TOP ACCESSORIES
Compression belt
Hand grips
Legs support
Patient table-top mattress
Lateral detector support
Foot pedal for table-top vertical movement
WALL STAND ACCESSORIES
Arms support
WIRELESS DETECTOR ACCESORIES
External detector support with anti-scatter grid
OTHER ACCESSORIES
Desk for radiological system
15
DOSE: REDUCTION, MONITORING AND MANAGMENT
MEASURES TO REDUCE THE DOSE TO THE PATIENT AND THE OPERATORS
Exam table
Lower absorption carbon fiber patient table-top
Anti-scatter grid
Grid with carbone fiber cover
Generator integration with the digital High generator integration to optimize the anatomical techniques, ausystem
tomatic collimation, filtration and image processing
M Automatic exposure meter
Controlled by the generator to allow greater accuracy in the exposures
Paedriatic
anatomical
programs
Available in four different age size
L
High frequency generator providing high output voltage with a partiGenerator
curarly well-levelled ripple and with short start and end exposure
ramps.
Manual and automatic rectangular fields collimator with hardening
beam filters. The insertion of the filters is controllable by the operator
Collimator
and programable within the anatomical program.
Power LEDs for simulating the irradiated field.
DOSE CONTROL AND MANAGMENT
Allows the verification of exposure by measuring the deviation of the
Exposure index (EI)
image levels acquired compared to the one set in the exam.
Deviation index (DI)
The result is shown by the Exposure Index (EI) and the Deviation
Index (DI).
H
Dose – area measurement
Value measured by ionization chamber located at the collimator outdevice (DAP)
put
DAP/AIR KERMA display
Values are displayed in the generator integrated console section
The cumulated patient’s dose values areas transmitted to the RIS using
DICOM MPPS.
RIS-PACS transmission
The complete exam dose report is transmitted to the PACS via DICOM
DOSE SR
16
(I)
INFOTEC
DIAGNOSTIC EXAM ROOM: TYPICAL OVERALL
CONFIGURATION WITH TABLE AT FIXED HEIGHT
17
18
INFOTEC
CONFIGURATION WITH ELEVABLE TABLE
19
20
CALYPSO_F_AFM_Rev_I_MAEN.docx – 2022-12-22– data subject to change without notice