Technical Datasheet Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Quotation: Item no.: Date: Page: 1 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Operating point 1 139929 100 12/06/2023 / 4 Version No.: 1 Dimensioning operating point Operating conditions (purchaser requirements) Target flow rate Target mass flow rate Target head Fluid Fluid variant Specified fluid temperature 36 m³/h 10.3 kg/s 14.85 m Wastewater, municipal untreated 20 °C Density Fluid handled Kinematic viscosity Fluid handled 1,030 kg/m³ 1 mm²/s Vapour pressure determined 0.0234 bar.a Minimum allowed ambient -20 °C temperature Maximum allowed ambient 40 °C temperature Installation altitude above sea 1,000 m level Operating conditions (performance) Flow rate Head Shut-off head Efficiency Pump 37.72 m³/h 16.3 m 26.29 m 42.2 % Maximum power input at duty point Maximum power input / curve Pump speed Discharge pressure-max. 4.09 kW Pump with stationary installation parts S Close-coupled Single-pump system 4.5 m 160 mm Free flow impeller 65 mm Pump directive CE Without Nominal diameter Discharge nozzle Nominal pressure Discharge nozzle Discharge flange bolt hole pattern as per standard DN 65 4.25 kW 2,918 1/min 2.66 bar Design data pump Scope of supply Pump supplied by KSB Installation code Pump design Pump system design Installation depth Impeller diameter D2 Impeller type Free passage Nozzle connections pump Nominal diameter Suction nozzle Nominal pressure Suction nozzle Suction flange bolt hole pattern as per standard PN 16 Without PN 16 Drawing Technical Datasheet Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Quotation: Item no.: Date: Page: 2 139929 100 12/06/2023 / 4 Version No.: 1 Shaft sealing Shaft seal type DMS tandem Mechanical seal type inboard Material Shaft seal inboard Mechanical seal type outboard Material Shaft seal outboard MG1G36 Q1Q1PGG MG1G6 Material motor housing Material Power cable sheath Material Bolts/Screws Hydraulic casing Material Impeller fastening Material Lifting tackle Pump/ mixer Material Elbow Outlet Material Claw, wet installation Material Guide wire EN-GJL-250/A48 CL 35B PE-C A4-70 BVPGG Materials Design concept Material Volute casing Material Casing cover Material Shaft Material Impeller Material Static seal Hydraulic casing Material Inlet part suction-side Material Bearing bracket housing pump-end G EN-GJL-250/A48 CL 35B EN-GJL-250/A48 CL 35B 1.4021+QT800 EN-GJL-250/A48 CL 35B NBR 70 EN-GJL-250/A48 CL 35B EN-GJL-250/A48 CL 35B A4-80 1.4404 EN-GJL-250/A48 CL 35B EN-GJL-250/A48 CL 35B 1.4401/A276 TP 316 Technical Datasheet Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Quotation: Item no.: Date: Page: 3 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 139929 100 12/06/2023 / 4 Version No.: 1 Driver Drive concept Motor manufacturer Motor size Motor version Rolling element bearing type non-drive end (Basic symbol) Efficiency class Motor cooling method Enclosure Motor Thermal class Temperature sensor motor Operation on a frequency inverter permitted Length Power cable Quantity Power cables Cable type Power cable Cable cross-section Power cable Quantity Control cables Cable type Control cable Seal Cable gland Submersible motor With electric actuator KSB NG10L U Single-row deep groove ball bearing 6306 IE3 (Premium) Surface cooling IP68 180 (H) nach IEC 60085 Bimetal switch Yes (acc to motor manufact) 10 m 1 S1BN8-F 12G1.5 0 Without Resin-sealed, absolutely watertight Rated speed Motor Number of motor poles Rated power Motor Motor power reserve determined Mains type Motor Rated voltage Motor Rated frequency Motor Motor starting method Motor switching type Rated current Motor Starting current ratio Ia/In Cos phi at 4/4 load Motor efficiency at 4/4 load Motor service factor Explosion protection directive Drive Moisture protection monitoring Submersible motor Motor power P1 P1 at 4/4 load Specific energy Flow rate Number of motor starts (per hour) 2,904 1/min 2 4.54 kW 11.1 % Three-phs alternating current 400 V 50Hz Star-delta Delta 10.1 A 12.4 0.74 88.6 % 1.15 Without Leakage sensor 4.6 kW 5.13 kW 0.122 kWh/m³ 30 Guide wire arrangement Pump (bracket(s) and wire) Installation parts / Accessories Stationary guide wire Quantity Spacer Guide wire Nominal guide wire diameter Guidance length Nominal size Inlet Elbow DN 65 Claw Nominal size Outlet Elbow Standard Bolt hole pattern Connection Outlet Elbow Connection element type Foundation DN 65 EN1092-2 Claw design Nominal size Inlet Claw Nominal size Outlet Claw Installation type Duckfoot Chemical anchors 0 5 mm 4.5 m Vertical DN 65 DN 65 Technical Datasheet Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Quotation: Item no.: Date: Page: 4 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Version No.: 1 Lifting tackle / Lifting parts Lifting tackle Pump/mixer Length Lifting tackle Pump/ mixer Maximum load Lifting tackle Pump/mixer Chain 5m 200 kg Coating Surface preparation Properties Top coat Thickness Top coat Colour Top coat Free from dirt, grease, rust 2-comp epoxy resin, high solid 80 µm RAL5002 Ultramarine Blue Nameplates Packaging Suitable for transport Suitable for storage Packaging category Sea freight Outdoor storage Wooden box for outdoor storage (B01) Duplicate name plate Additional text Name plate Yes No 139929 100 12/06/2023 / 4 Performance Curve (Pump) Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Quotation: Item no.: Date: Page: 1 139929 100 12/06/2023 / 1 Version No.: 1 Curve Data Pump speed Density Fluid handled Kinematic viscosity handled Flow rate Target flow rate Head Target head 2,918 1/min 1,030 kg/m³ Fluid 1 mm²/s 37.72 m³/h 36 m³/h 16.3 m 14.85 m Efficiency Pump Maximum power input at duty point NPSH required Characteristic curve number Impeller diameter D2 Hydraulic calculation according to standard/class 42.2 % 4.09 kW 0m K2573-52-65170F/2 160 mm EN ISO 9906 §4.4.2 (pump input power below 10 kW) Installation plan Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Quotation: Item no.: Date: Page: 1 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Drawing is not to scale. Connect pipelines stress-free Version No.: 1 Dimensions are given in mm Motor Motor manufacturer Motor size Rated power Motor Number of motor poles Rated speed Motor H 139929 100 12/06/2023 / 2 Connections KSB NG10L 4.54 kW 2 2,904 1/min Nominal diameter Suction nozzle Suction flange bolt hole pattern as per standard Nominal diameter Discharge nozzle Discharge flange bolt hole pattern as per standard Nominal pressure Suction nozzle Nominal pressure Discharge nozzle Without Without DN 65 Drawing PN 16 PN 16 Net weight Total weight Pump Total weight Pipe adaptation 94.83 kg 16.23 kg Installation plan Customer Item No.: Inquiry Date: 12/06/2023 Inquiry No.: Quantity: 2 Amarex F 065-170 G ARX F065-170/045C2USG -160 /12100L000 Dimensional tolerances for shaft axis height: DIN 747 Dimensions without tolerances, middle tolerances to: ISO 2768-m Connection dimensions for pumps: EN735 Dimensions without tolerances - welded parts: ISO 13920-B Dimensions without tolerances - gray cast iron parts: ISO 8062-CT9 Quotation: Item no.: Date: Page: 2 139929 100 12/06/2023 / 2 Version No.: 1 Total weight Installation parts Total weight Pump set 3.75 kg 114.8 kg Plan for additional connections see extra drawing