Uploaded by yousef saleh

1- Technical ARX F065-170-045C2USG

advertisement
Technical Datasheet
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Quotation:
Item no.:
Date:
Page:
1
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Operating point
1
139929
100
12/06/2023
/ 4
Version No.: 1
Dimensioning operating point
Operating conditions (purchaser requirements)
Target flow rate
Target mass flow rate
Target head
Fluid
Fluid variant
Specified fluid temperature
36 m³/h
10.3 kg/s
14.85 m
Wastewater, municipal
untreated
20 °C
Density Fluid handled
Kinematic viscosity Fluid
handled
1,030 kg/m³
1 mm²/s
Vapour pressure determined
0.0234 bar.a
Minimum allowed ambient
-20 °C
temperature
Maximum allowed ambient
40 °C
temperature
Installation altitude above sea 1,000 m
level
Operating conditions (performance)
Flow rate
Head
Shut-off head
Efficiency Pump
37.72 m³/h
16.3 m
26.29 m
42.2 %
Maximum power input at duty
point
Maximum power input / curve
Pump speed
Discharge pressure-max.
4.09 kW
Pump with stationary
installation parts
S
Close-coupled
Single-pump system
4.5 m
160 mm
Free flow impeller
65 mm
Pump directive
CE
Without
Nominal diameter Discharge
nozzle
Nominal pressure Discharge
nozzle
Discharge flange bolt hole
pattern as per standard
DN 65
4.25 kW
2,918 1/min
2.66 bar
Design data pump
Scope of supply Pump
supplied by KSB
Installation code
Pump design
Pump system design
Installation depth
Impeller diameter D2
Impeller type
Free passage
Nozzle connections pump
Nominal diameter Suction
nozzle
Nominal pressure Suction
nozzle
Suction flange bolt hole
pattern as per standard
PN 16
Without
PN 16
Drawing
Technical Datasheet
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Quotation:
Item no.:
Date:
Page:
2
139929
100
12/06/2023
/ 4
Version No.: 1
Shaft sealing
Shaft seal type
DMS tandem
Mechanical seal type inboard
Material Shaft seal inboard
Mechanical seal type
outboard
Material Shaft seal outboard
MG1G36
Q1Q1PGG
MG1G6
Material motor housing
Material Power cable sheath
Material Bolts/Screws
Hydraulic casing
Material Impeller fastening
Material Lifting tackle Pump/
mixer
Material Elbow Outlet
Material Claw, wet installation
Material Guide wire
EN-GJL-250/A48 CL 35B
PE-C
A4-70
BVPGG
Materials
Design concept
Material Volute casing
Material Casing cover
Material Shaft
Material Impeller
Material Static seal Hydraulic
casing
Material Inlet part suction-side
Material Bearing bracket
housing pump-end
G
EN-GJL-250/A48 CL 35B
EN-GJL-250/A48 CL 35B
1.4021+QT800
EN-GJL-250/A48 CL 35B
NBR 70
EN-GJL-250/A48 CL 35B
EN-GJL-250/A48 CL 35B
A4-80
1.4404
EN-GJL-250/A48 CL 35B
EN-GJL-250/A48 CL 35B
1.4401/A276 TP 316
Technical Datasheet
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Quotation:
Item no.:
Date:
Page:
3
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
139929
100
12/06/2023
/ 4
Version No.: 1
Driver
Drive concept
Motor manufacturer
Motor size
Motor version
Rolling element bearing type
non-drive end (Basic symbol)
Efficiency class
Motor cooling method
Enclosure Motor
Thermal class
Temperature sensor motor
Operation on a frequency
inverter permitted
Length Power cable
Quantity Power cables
Cable type Power cable
Cable cross-section Power
cable
Quantity Control cables
Cable type Control cable
Seal Cable gland
Submersible motor
With electric actuator
KSB
NG10L
U
Single-row deep groove ball
bearing 6306
IE3 (Premium)
Surface cooling
IP68
180 (H) nach IEC 60085
Bimetal switch
Yes (acc to motor manufact)
10 m
1
S1BN8-F
12G1.5
0
Without
Resin-sealed, absolutely
watertight
Rated speed Motor
Number of motor poles
Rated power Motor
Motor power reserve
determined
Mains type Motor
Rated voltage Motor
Rated frequency Motor
Motor starting method
Motor switching type
Rated current Motor
Starting current ratio Ia/In
Cos phi at 4/4 load
Motor efficiency at 4/4 load
Motor service factor
Explosion protection directive
Drive
Moisture protection
monitoring Submersible motor
Motor power P1
P1 at 4/4 load
Specific energy Flow rate
Number of motor starts (per
hour)
2,904 1/min
2
4.54 kW
11.1 %
Three-phs alternating current
400 V
50Hz
Star-delta
Delta
10.1 A
12.4
0.74
88.6 %
1.15
Without
Leakage sensor
4.6 kW
5.13 kW
0.122 kWh/m³
30
Guide wire arrangement Pump (bracket(s) and wire)
Installation parts / Accessories
Stationary guide wire
Quantity Spacer Guide wire
Nominal guide wire diameter
Guidance length
Nominal size Inlet Elbow
DN 65
Claw
Nominal size Outlet Elbow
Standard Bolt hole pattern
Connection Outlet Elbow
Connection element type
Foundation
DN 65
EN1092-2
Claw design
Nominal size Inlet Claw
Nominal size Outlet Claw
Installation type
Duckfoot
Chemical anchors
0
5 mm
4.5 m
Vertical
DN 65
DN 65
Technical Datasheet
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Quotation:
Item no.:
Date:
Page:
4
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Version No.: 1
Lifting tackle / Lifting parts
Lifting tackle Pump/mixer
Length Lifting tackle Pump/
mixer
Maximum load Lifting tackle
Pump/mixer
Chain
5m
200 kg
Coating
Surface preparation
Properties Top coat
Thickness Top coat
Colour Top coat
Free from dirt, grease, rust
2-comp epoxy resin, high solid
80 µm
RAL5002 Ultramarine Blue
Nameplates
Packaging
Suitable for transport
Suitable for storage
Packaging category
Sea freight
Outdoor storage
Wooden box for outdoor
storage (B01)
Duplicate name plate
Additional text Name plate
Yes
No
139929
100
12/06/2023
/ 4
Performance Curve (Pump)
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Quotation:
Item no.:
Date:
Page:
1
139929
100
12/06/2023
/ 1
Version No.: 1
Curve Data
Pump speed
Density Fluid handled
Kinematic
viscosity
handled
Flow rate
Target flow rate
Head
Target head
2,918 1/min
1,030 kg/m³
Fluid 1 mm²/s
37.72 m³/h
36 m³/h
16.3 m
14.85 m
Efficiency Pump
Maximum power input at duty
point
NPSH required
Characteristic curve number
Impeller diameter D2
Hydraulic
calculation
according to standard/class
42.2 %
4.09 kW
0m
K2573-52-65170F/2
160 mm
EN ISO 9906 §4.4.2 (pump
input power below 10 kW)
Installation plan
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Quotation:
Item no.:
Date:
Page:
1
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Drawing is not to scale.
Connect pipelines stress-free
Version No.: 1
Dimensions are given in mm
Motor
Motor manufacturer
Motor size
Rated power Motor
Number of motor poles
Rated speed Motor
H
139929
100
12/06/2023
/ 2
Connections
KSB
NG10L
4.54 kW
2
2,904 1/min
Nominal diameter Suction nozzle
Suction flange bolt hole pattern as
per standard
Nominal diameter Discharge nozzle
Discharge flange bolt hole pattern
as per standard
Nominal pressure Suction nozzle
Nominal pressure Discharge nozzle
Without
Without
DN 65
Drawing
PN 16
PN 16
Net weight
Total weight Pump
Total weight Pipe adaptation
94.83 kg
16.23 kg
Installation plan
Customer Item No.:
Inquiry Date:
12/06/2023
Inquiry No.:
Quantity:
2
Amarex F 065-170 G
ARX F065-170/045C2USG -160 /12100L000
Dimensional tolerances for shaft axis height: DIN 747
Dimensions without tolerances, middle tolerances to: ISO
2768-m
Connection dimensions for pumps: EN735
Dimensions without tolerances - welded parts: ISO 13920-B
Dimensions without tolerances - gray cast iron parts: ISO
8062-CT9
Quotation:
Item no.:
Date:
Page:
2
139929
100
12/06/2023
/ 2
Version No.: 1
Total weight Installation parts
Total weight Pump set
3.75 kg
114.8 kg
Plan for additional connections see extra drawing
Download