Webinar TIA Portal Mars 2023 Delivery releases Page 2 SIMATIC Hardware New Hardware for CPUs ≤ 1516 starts with FW V3.0 & TIA Portal V18 New Hardware with 2 Core Processor Core 2 Single Core Core 1 • Core 1 • User program • Diagnoses • Core 2 • Communication New Display implementation Benefits → Deterministic program processing (smaller jitter) → Higher communication performance → No separate Display FW needed 6ES751x-xyyx0/1/2-0AB0 FW ≤ V2.9 Page 3 Unrestricted | © Siemens 2022 | DI FA | November 2022 6ES751x-xyyx03-0AB0 FW = V3.0 SIMATIC Hardware New Hardware for CPUs ≤ 1516 starts with FW V3.0 & TIA Portal V18 The new hardware offers • More memory • More Performance • Higher communication performance (2nd core) +100% +50% 2nd / 3rd Step: • Gbit Ethernet on X2 of the CPU 1515 /1516 • 2nd PN Interface with IRT Program +140% +60% 1511 1513 Data Memory FW V2.9 (current articel no.) Page 4 Unrestricted | © Siemens 2022 | DI FA | November 2022 +400% +67% 1515 1516 Program Performance FW V3.0 (new articel no.) SIMATIC Hardware New Hardware for CPUs ≤ 1516 starts with FW V3.0 & TIA Portal V18 ➢ more resources for future customer application extensions +100% more program- and data memory +100% kByte kByte +50% +100% +50% +100% +100% +100% +33% +100% 1510SP 1511 1512SP 1513 1514SP 1515 1516 1510SP Program memory Unrestricted | © Siemens 2022 | DI FA | November 2022 1511 1512SP +67% 1513 1514SP 1515 1516 Data memory Standard and Fail Safe Page 5 +50% +100% FW V2.9 (current article no.) FW V3.0 (new article no.) SIMATIC Hardware Increase/harmonization of quantity structure Ambient temperature • CPU 1511-1516 from -25°C - +60°C → -30°C - +60°C Retentive Data • CPU 1510SP-1513 from 128 kB to 256 kB ➢ Same temperature range as most of IO modules ➢ Usable in more customer applications ➢ Easier controller selection ➢ More memory space to prevent data loss in the event of power failure Min. OB 3x cycle • CPU 1510SP-1515 from 500µs to 250µs UDP multicast circuits • CPU 1510SP-1513 from 5 to 78 • CPU 1515-1516 from 5 to 118 Page 6 Unrestricted | © Siemens 2022 | DI FA | November 2022 ➢ More frequent processing of program parts ➢ Significantly more participants can be reached via UDP Multicast SIMATIC Hardware Compatibility 1. CPU 1510SP to CPU 1516 • • 2. CPU 1517/1518 FW V3.0 only for new article numbers Full spare part compatible: New HW / FW V3.0 Parallel delivery of the old and new HW for 6-12 month: TIA Portal V18 Current HW / FW ≤ V2.9 New HW / FW V3.0 6-12 month S7-1500 12-18 month ET 200SP Page 7 Unrestricted | © Siemens 2022 | DI FA | November 2022 Same HW as today • New functionality with FW V3.0 upgrade also for existing CPUs 3. Compact and ET 200pro CPUs Current HW / FW V1.8 - V2.9 • • • Same HW and FW (V2.9) as today • No new functionality with TIA Portal V18! 4. Support of FO/LC BusAdapter for ET 200SP CPUs 1512SP(F) first with 2nd step (TIA Portal V19) HW Page 8 HW Page 9 S7 1500 Core 1/Core 2 Page 10 New HW Firmware V 3.0 Page 11 SIMATIC S7-1500 / ET 200SP CPUs New Hardware-Version for CPU 1511T/TF and 1515T/TF The new hardware offers: • More memory • More performance • Higher communication performance (2nd core) • CPU 1511T/TF more Motion Control Resources +100% +50% +400% +50% +50% +140% New CPUs: • • • • CPU 1511T-1 PN CPU 1515T-2 PN CPU 1511TF-1 PN CPU 1515TF-2 PN 6ES7511-1TL03-0AB0 6ES7515-2TN03-0AB0 6ES7511-1UL03-0AB0 6ES7515-2UN03-0AB0 Program Data Memory 1511T/TF 1515T/TF Program Performance FW 2.9 (current HW) Page 12 Unrestricted | © Siemens 2022 | DI FA PMA | November 2022 FW 3.0 (new HW) 1511T/TF 1515T/TF Motion Control Performance Portfolio enhancement with SIMATIC S7-1514SP T/TF A new technology CPU in the design of a SIMATIC ET200SP Controller SIMATIC S7-1514 SP T/TF for midrange Motion Control Extendable and economic solution for the midrange Motion Control market Powerful SIMATIC ET200SP Controller especially designed for the requirements of the midrange Motion Control applications Same performance in comparison to newly S7-1515 Provides access to the extensive range of the ET200 SP IO modules including newly designed PTO2 modules for stepper drives Page 13 Unrestricted | © Siemens 2022 | DI FA PMA | November 2022 Portfolio enhancement with SIMATIC S7-1514SP T/TF facts and figures at a glance Distributed Controller Components CPU 1514SP T/TF-2 PN CPU Type PN IO Interface X2 (RJ45) Interfaces 1 2 1 1 PROFINET IO with IRT 2 PROFINET IO with RT 6 ns Bit performance 900 kB 3,5 MB Program memory Data memory Motion Control Resources 1 Ext. Motion Control Res. 2 2.400 120 Positioning axes: Maximum 30 Performance estimates 3 PN IO Interface X1 BusAdapter (BA) PN Port 1 and PN Port 2 (RJ45) 1 Resources for Motion Control technology objects: 2 Resources for Extended Motion Control technology objects: 3 Estimated values are subject to implementation of use case 4 With 4 ms Servo/IPO-cycle time and 35% CPU usage for motion control Page 14 Unrestricted | © Siemens 2022 | DI FA PMA | November 2022 Positioning axes: Typical 11 in 4 ms 4 Speed axis = 40 | Positioning Axis = 80 | Sychr. Axis = 160 | Output cam = 20 | Output cam track = 160 | Measuring input = 40 | Ext. Encoder = 20 Cams (1.000 points and 50 segments) = 2 | Cams (10.000 points and 50 segments) = 20 | Kinematic objects = 30 | leading axis proxy = 3 New SIMATIC Hardware PROFINET System Redundancy R1 for S7-1500H and ET 200SP H-CPU 1 H-CPU 2 Increased plant availability with R1 redundancy • Higher robustness in case of outage of components • Seamless failover when one Interface Module fails Redundancy now also on I/O Level • The new redundant IM 155-6PN R1 for ET 200SP can be combined with all existing IO modules of ET 200SP • Also supported: R1 with ET 200SP HA and ET 200iSP ET 200SP with redundant IM Network 1 Redundant Networks Network 2 Redundant Interface on ET 200 each with 1 relation to a H-controller Page 15 Unrestricted | © Siemens 2022 | DI FA | November 2022 • Process continues even in case of a complete network breakdown • Redundant and single networks can be combined R1 can be used with existing S7-1500H PLCs • No new PLC hardware needed • TIA Portal V18 and Firmware Update to V3.0 enables R1 redundancy in the PLCs Switching behavior with PROFINET System RedundancyR1 Initial Situation Primary Controller Primary Controller is connected to Interface Module 1 (IM1) Backup Controller is connected to Interface Module 2 (IM2) RUN R1 RUN PROFINET Backup Controller PROFINET R1-Device IM1 IM2 Process values are exchanged Process Values Primary AR Backup AR Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 Switching behavior with PROFINET System RedundancyR1 Scenario: A controller fails – switching process begins R1 RUN Remaining controller takes over automatically. The existing connection is activated PROFINET Primary Controller PROFINET R1-Device IM1 IM2 Process values are used for a very short time1) frozen: I/O values remain at the last value 1) Duration approx. 40ms Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 Process Values Primary AR Backup AR Switching behavior with PROFINET System RedundancyR1 Initial Situation Primary Controller Primary Controller is connected to Interface Module 1 (IM1) Backup Controller is connected to Interface Module 2 (IM2) RUN R1 RUN PROFINET Backup Controller PROFINET R1-Device IM1 IM2 Process values are exchanged Process Values Primary AR Backup AR Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 Switching behavior with PROFINET System RedundancyR1 Scenario: An interface module fails – switching process begins Primary Controller Backup Controller enables connection to Interface-Module 2 (IM2) RUN R1 RUN PROFINET Backup Controller PROFINET R1-Device IM1 IM2 Process values are used for a very short time1) frozen: I/O values remain at the last value 1) Duration approx. 40ms Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 Process Values Primary AR Backup AR Switching behavior with PROFINET System RedundancyR1 Scenario: An interface module fails - operation complete Primary Controller I/O data is transferred via sync line via the backup controller to the Primary controller. There is no controller switching. RUN R1 RUN PROFINET Backup Controller PROFINET R1-Device IM1 IM2 Process values are exchanged Process Values Primary AR Backup AR Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 New R1 Interface Module for ET 200SP Based on • 1 system rail R1, • 1 base unit M0, • 2 IM R1, • 2 Bus Adapters*, • Same IO-modules as ET200SP. * New Bus Adapters with port LC-LD for optical fiber mono-mode, can be also used. (up to 20km with the IM R1). MLFBs Components MLFB IM155-6PN R1 6ES7155-6AU00-0HM0 BU-Typ M0 6ES7193-6BR00-0HM0 SIMATIC System Rail length 482,6mm 6ES7193-6MR00-0AA0 SIMATIC System Rail length 530mm 6ES7193-6MR00-0BA0 SIMATIC System Rail length 830mm 6ES7193-6MR00-0CA0 SIMATIC System Rail length 2000mm 6ES7193-6MR00-0DA0 BA 2xLC-LD 6ES71936AG50-0AA0 BA LC-LD/RJ45 6ES71936AG60-0AA0 BA LC-LD/M12 6ES71936AG70-0AA0 New SIMATIC Hardware Long Distance H-Sync for S7-1500H New Long Distance Sync-Modules for S7-1500H • In addition to existing 10 m / 10 km Sync Modules • Needed to connect the fiber-optic cables for H-Synchronization H-CPU 2 H-CPU 1 Distances between H-Controller up to 40 km Max. 40 km New Long Distance H-Sync Module • This allows to use the S7-1500H System also in applications with large dimensions • Mainly: Tunnel Applications Compatible to existing H-Controller • Can be used with existing H-Controller CPU 1517H and CPU 1518HF • Firmware Update Synchronization of H-PLCs (Redundant fiber-optic cables) R1 can be used with existing S7-1500H PLCs • No new PLC hardware needed • TIA Portal V18 and Firmware Update to V3.0 is needed to use the new H-Sync Module Page 24 Unrestricted | © Siemens 2022 | DI FA | November 2022 SIMATIC S7-1500 Redundant Systems Sync modules and sync lines Sync Module 4 pieces per H-system Sync Cable 2 pieces per H-system Distance Sync Module Sync Cable Fiber Type / Connector Up to 10 m 6ES7960-1CB00-0AA5 Pre-fabricated: 6ES7 960-1BB00-5AA5 (1m) 6ES7 960-1BC00-5AA5 (2m) 6ES7 960-1CB00-5AA5 (10m) Multimode / LC From 2 m to 10 km 6ES7960-1FB00-0AA5 Single mode fiber 9/125 µm Specification OS1 or OS2 Single Mode/LC From 8 km to 40 km 6ES7960-1FE00-0AA5 Single mode fiber 9/125 µm Specification OS2 Single Mode/LC New Overview of fiber optics at Siemens: https://mall.industry.siemens.com/mall/en/en/Catalog/Products/10000396?tree=CatalogTree Unrestricted | © Siemens 2023 | DI FA | 01.02.2023 SIMATIC S7-1500 Redundant Systems CPU Types New Program/ Memory Interfaces Firmware SIPLUS variant New CPU 1513R-1 PN CPU 1515R-2 PN CPU 1517H-3 PN CPU 1518HF-4 PN 6ES7513-1RM03-0AB0 6ES7515-2RN03-0AB0 6ES7517-3HP00-0AB0 6ES7518-4JP00-0AB0 600 kB Code 2.5 MB of data 1 MB Code 4.5 MB of data 2 MB Code 8 MB data 9 MB Code 60 MB data X1 X1 X2 X1 X2 X3 X4 X1 X2 X3 X4 From V3.0 From V3.0 From V2.6 From V2.8 - - 6AG1517-3HP00-4AB0 - Fail-safe PROFINET IO Controller, Supports RT, MRP, TCP/IP, Open User Communication PROFINET Basic Services, TCP/IP, Open User Communication SFP module slot for H-synchronization Unrestricted | © Siemens 2022 | DI FA | 08.12.2022 X5 STEP 7 – Innovations Namespaces for Software Units Demo Concept • Software Unit provides a “Namespace preset” • Every Block/UDT has an own “Namespace” property • In Clients (WinCC, OPC UA) always the full name (incl. namespace: Namepace.BlockName) is displayed • No namespace for global tags/variables in V18 Benefits • Block names can be used several times in the PLC program Improved IEC 61131-3 conformity • No special characters except “_” • No quotation marks in the code for block names • “_.” : Extension of the referencing concept Seite 27 Unrestricted | © Siemens 2022 | DI FA | November 2022 STEP 7 – Innovations Failsafe program in Software Units Boundary conditions • Global Setting to activate feature • Empty F-Unit is created with a new CPU • Entire failsafe program in one F-Unit • Existing failsafe program are copied to the new CPU • No delete/copy/create of F-Unit • No master copy of F-Unit • Safety Administration as usual Advantages • Use of Units features: • Unit-granular download • Publishing data & data exchange between units • Namespaces also for F-Unit Page 28 Unrestricted | © Siemens 2022 | DI FA | November 2022 OPC UA communication from/to controller Strategy Cloud • OPC UA mainly for vertical and controller to controller communication Cloud Page 29 28.03.2023 OPC UA PROFINET Ethernet / Ethernet TSN MES, ERP • PROFIsafe to exchange Safety Managementlevel signals between controllers SCADA, DCS • PROFINET for cyclic and realOperatorlevel Controllerlevel Fieldlevel Machine time capable I/O data exchange on the field level Machine • Benefit: PROFINET and OPC PLC PLC UA can share the same network! Workshop Page 30 OPC UA Generelt Page 31 OMAC IT supplier Client OMAC: Opprettet i 1994, Brukergruppe for å utlede felles løsninger Server Shop floor OEM1 OEM2 OEM3 OEM3 OEM1 Machine Builder Page 32 Internal | © Siemens 2022 End Customer SIMATIC S7-1500 OPC UA Server Functional scope – SiOME Siemens OPC UA Modeling Editor (SiOME) for implementing OPC UA companion specifications COMPANION SPECIFICATIONS IMPORT Types according to specification Instances/ models >according to specification DB Instance DB https://support.industry.siemens.com/cs/us/en/view/109755133 EXPORT Types, Instances, Mapping • Standardized OPC UA interfaces • Information modelling Page 33 Internal | © Siemens 2022 MAPPING TIA V18 Read List, Write List Page 34 OPC UA – Quantity structures @ S7-1500 Improvements for server interface & subscriptions ➢ Higher number of nodes within user-defined server interfaces ➢ More subscriptions per session ➢ Higher amount of max. recommended monitored items CPU 1510…13 (within 1s sampling/publish) CPU 1515/16 V17 V18 / FW3.0 V17 V18 / FW3.0 10 10 10 10 1,000 15.000 5,000 30.000 20 50 20 50 No. of monitored items per subscriptions, max. 10,000 10,000 10,000 10,000 Sampling interval, min. 100ms 100ms 100ms 100ms Publishing interval, min. 500ms 200ms 200ms 100ms Monitored items, max. 10,000 10,000 20,000 20,000 Recommended monitored items, max for 1 s sampling & 1 s publish interval 1,000 4.000 2,000 4.000 Server Interface No. of server interfaces, max. No. of nodes for user-defined server interfaces, max. Subscriptions No. of subscriptions per session, max. *) more details / help to subscriptions: https://support.industry.siemens.com/cs/ww/de/view/109755846 Page 35 Unrestricted | © Siemens 2022 | DI FA | November 2022 Certificate Management via OPC UA for S7-1500 GDS Support Certificate management is now possible through OPC UA Global Discovery Server - GDS Certificate update at runtime ▪ Support of Certificate Revocation Lists - CRLs ▪ Access protection for certificate management Benefits ▪ Install or update the OPC UA server certificate during runtime ▪ Implement security concepts based on short validity period ▪ Revoke certificates during runtime ▪ Restrict access when employees leave the company or when the system is compromised Page 36 Unrestricted | © Siemens 2021 | SITRAIN – Digital Industry Academy OPC UA GDS Server GDS Push ▪ OPC UA Server certificate S7-1500 CPU with OPC UA GDS support Trust-List Revocation List (CRL) … or TIA Portal PLCSIM Advanced V5.0 Page 37 S7-PLCSIM Advanced V5.0 New communication mode “TCP/IP Multi Adapter” – full flexibility network topologies Multi Adapter Mode – multiple network adapter mapped to one simulation instance Cloud environment like AWS, Azure,… Or local VM vSphere Server etc… Or physical PCs e.g. Subnet 1 = Automation Test Network e.g. Subnet 2 = ERP Test Network PC/VM1 PLCSIM instance 1 S7-1513 PC/VM2 PLCSIM instance 2 S7-1518 PLCSIM instance 2 S7-1518 X1 X2 X3 X4 X1 X2 X3 X4 X1 PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual Switch PLCSIM virtual. Eth. Adapter vNetwork Adapter vNetwork Adapter vNetwork Adapter PLCSIM virtual. Eth. Adapter vNetwork Adapter vNetwork Adapter Virtualized infrastructure switch vNIC Subnet 1 v=virtualized Page 38 Unrestricted | © Siemens 2022 | DI FA | November 2022 Switch vNIC Subnet 2 Demo STEP 7 – Innovations Long-term Trace Long-term Trace for better analyzing sporadic errors or optimize machinery parameterization ▪ Recording of up to 641 different signals2 in “csv”-files for a long time (days, weeks, months ….) ▪ Limitation only thru available hard disk memory on PC ▪ Motion-Cycle-synchronous (e.g. MC-Servo) recording ensures qualified analyzes of the signals ▪ Configuration/Start/Stop of the Long-term Trace job via Trace-Editor ▪ The recorded values can be shown and analyzed in the Trace-Editor ▪ The recorded “csv”-files can be exported and analyzed via third party tools also 1 with FW V3.0 2 Supported: Bool, Byte, INT, DINT, LINT, USINT, UINT, UDINT, ULINT, WORD, DWORD, LWord, REAL, LREAL, Date, Time, LTime, Time Of Day, Long Time Of Day, Long Date Time Not supported: whole Arrays/Structs/UDTs, Date_And_Time, Date_And_LTime, Char, WChar, String, S5Count, S5Time... Page 39 Unrestricted | © Siemens 2022 | DI FA PMA | November 2022 STEP 7 – Innovations General Improvements Special marking of InOut parameters in LAD/FBD/Graph Search&Replace of hidden block parameters Search&Replace in TagTable – Replace All InOut parameters have a special marking in block calls to better differentiate them from In parameters Find&Replace in LAD/FBD blocks finds now actual parameters on block calls with hidden parameters. "Replace all" with all its options is now supported in the PLC tag table Before Now Seite 40 Unrestricted | © Siemens 2022 | DI FA | November 2022 STEP 7 – Innovations General Improvements New checksum “Program code” in compare editor Watch table – New shortcut to modify values of multiple variables The new checksum only takes the source code into account. Spaces, line breaks, tabs and comments of all types are not included. They are now part of the checksum “Program code (legacy)” A new context menu in the watch table makes it easier to change the value of several selected variables. Seite 41 Unrestricted | © Siemens 2022 | DI FA | November 2022 System functions Library – Compare of Libraries Check Compare Result Define Action Filter Compare Result Compare of global libraries and project libraries Use case • Compare of library types and master copies between global libraries and project library Feature New Library Compare editor to compare library types and master copies is now available with the following key features. • Different compare criteria can be configured to, e.g. compare Library Types based on Version GUID or compare of master copies by name. • Filter compare results is supported • Update libraries differences between libraries can be configured and be executed in single and mass opertions. Benefit • Easy way to compare libraries, find the differences and update changes between libraries. Seite 42 Unrestricted | © Siemens 2022 | DI FA | November 2022 High level compare of library content Detailed compare of library properties TIA Portal Teamcenter Gateway OUR EXISTING TIA PORTAL ECOSYSTEM grows for maximum flexibility to address IT-like needs Limited Sales Release together with TIA Portal V181 1 No free market access of SIMATIC AX. Please contact your local DI FA Sales Representative regarding technical limitations and purchase Page 43 Unrestricted | © Siemens 2022 | DI FA | November 2022 SIMATIC Target 1500S for Simulink TIA Portal Multiuser SIMATIC Energy Suite SIMATIC S7-PLCSIM Advanced SIMATIC STEP 7 SIMATIC WinCC SIRIUS Simocode SIMATIC Visualization Architect SIMATIC STEP 7 Safety SIMATIC Automation Tool SiOME TIA Portal VCI SINETPLAN TIA Portal Test Suite WinCC Web ES SIMOTION Scout SINAMICS Startdrive … PRONETA TIA User Management Component SINAMICS DCC TIA Portal Cloud Connector Industrial Edge SIMATIC AX TIAX use case Library Development Application Engineering SIMATIC AX STEP 7 TIA Portal New version of TIA Portal library Program library functionality Test library Generate/update Global TIA Portal Library Debug library on PLC: Monitoring and tracing of variables (simultaneously with TIA Portal) Page 44 Unrestricted | © Siemens 2022 | DI FA | November 2022 Create hardware configuration Open and update library Create machine application Download HW config & code to PLC Monitor & debug variables TIA Portal Cloud Overview of new functions TIA Portal Cloud V3.0 TIA Portal Cloud is a highly efficient online service that enables you to work in a virtual environment. Anywhere at any time! What is new: TIA Portal Cloud V3.0 (11/2022) • Integration of TIA Portal V18 TIA Portal Cloud V2.3 (09/2022) • Product updates and security fixes TIA Portal Cloud V2.2 (07/2022) • Performance improvements for download to SIMATIC hardware TIA Portal Cloud V2.1 (05/2022) • Online functions with local SIMATIC hardware • Integration of SIMIT Demo Seite 45 Frei verwendbar | © Siemens 20XX | Autor | Abteilung | TT.MM.JJJJ TIA Portal Cloud Online functionality via TIA Portal Cloud Connector Internet / Cloud TIA Portal Cloud Connector The TIA Portal Cloud Connector is now an integral part of TIA Portal Cloud and enables the use of TIA Portal online functions with local SIMATIC hardware. TIA Portal Cloud Secure connection Features On-site • Access to all online functionalities • Performant download to devices TIA Portal Cloud Connector Seite 46 Frei verwendbar | © Siemens 20XX | Autor | Abteilung | TT.MM.JJJJ • Secure connection of devices • No license needed for Cloud Connector System functions Upgrading projects TIA Portal V13 SP1/SP2 ≤V13 project V13 SP1 project Project upgrade to V13 SP1 TIA Portal >V13 >V13 project TIA Portal V18 V18 project Project upgrade to V18 Side-by-side installation of V13 SP1/SP2 up to V18 allows access to all project versions. The V18 license can be used for all available versions from V11. Page 47 Unrestricted | © Siemens 2022 | DI FA | November 2022 Takk for oppmerksomheten Håkon Nilssen Sales Specialist haakon.nilssen@siemens.com Mobile: 0047 92226801 ISM 2018