BECM 4200: Professional Practice Building Construction Act According to Bangladesh Imarat Nirman Bidhimala-2008 Presented to: Md. Shahriar Hossain Assistant Professor Group 02 Roll: 1823009 1823011 1823012 1823013 1823014 1823015 1823016 1823017 1823018 Khulna University of Engineering & Technology Department of Building Engineering and Construction Management 1823011 Floor area ratio (FAR) is the measurement of a building's floor area in relation to the size of the plot that the building is located on. What is FAR? 1823011 From Clause 51.1 : For Residential Building, for 7.5 Katha plot area – FAR = 4.00 18.29 m MGC = 60% (Taking 57.14%) Gross Floor Area FAR = Land Area FAR to No of Floor 4.0 = Gross Floor Area 27.44 m 501.93 Gross Floor Area = 2007.72 𝑚2 MGC = 57.14% of 501.93 𝑚2 = 286.80 𝑚2 No. of Floor = 2007.72 286.80 = 7.00 nos. 6 m Wide Road 1823011 1.50 m Setback Regulation 4 Katha – 18 road Katha For further increment, from the center of the road at 1.25 m least within 4.5 m no building can be constructed. 2.00 m [Clause: 46.2] 1823011 FAR with MGC • • • • • • [Clause: 51.2] Residential House & Residential Hotel Educational Building Institution & Health Serive Assembly and Religious Building Commercial Building Industrial Building 1823011 For A5 (Residential Hotel) buildings, if the land is bigger than 20 katha or is next to a road that's 18 meters wide or wider (excluding the space needed on the ground floor), one can have a podium that's up to 12 meters tall, including the parapet. Maximum Approval FAR [Clause: 51.2] 1823011 Open space on ground floor shall be considered FAR free. Maximum Approval FAR [Clause: 51.2] B1 (School, College, University) B2 (Kindergarten, Primary School) 20% 40% Class B1 and B2 use shall not be permitted up to 335 sq. meters or 5 kathas of land. 1823011 Considering the height of the podium up to 12 m with parapet wall for different structure based on the following condition: Building Type Institution & Health Service Maximum Approval FAR [Clause: 51.2] Condition Land Area: Above 20 Katha Road Width: 18 m Assembly & Religious Building Land Area: Any Road Width: 24 m Commercial Building Land Area: Any Road Width: Any 1823011 For Calculating FAR, room height should be considered as: Plain Surface = Maximum Floor Height 4.25 m Pitched Surface = Maximum Average Floor Height 4.25 m Maximum Room Height for FAR Calculation [Clause: 51.2] 1823011 For Calculating the room height: Calculation of FAR from Room Height If, 4.25 m > Floor Height < 6 m, Floor Area of that room, Floor Area (FA) = Floor Area (FA) + 50% of Room FA ; [50% RFA < 10% of Total Floor area (TFA)] If, Floor Height > 6 m, Floor Area of that room, Floor Area (FA) = Floor Area (FA) + 100% of FA ; 2nd condition can’t be used for the ground coverage of some specific building type. [Clause: 51.3] 1823011 For Calculating the room height: (An Example) Room Calculation of FAR from Room Height Total floor area Suppose, we have a building with a floor height of 5 m Room Area = 20 sq.m Floor Area = 120 sq.m [10% of 120 = 10 sq.m > 50% of 20 = 8 sq.m] So, Total Floor Area = 120 + 50% of 20 = 130 sq.m [Clause: 51.3] 1823011 For Calculating the room height: (An Example) Room Calculation of FAR from Room Height Total floor area Suppose, we have a building with a floor height of 7 m Room Area = 20 sq.m Floor Area = 120 sq.m So, Total Floor Area = 120 + 100% of 20 = 140 sq.m [Clause: 51.3] Maximum Ground Coverage 1823012 MGC or Maximum Ground Coverage is the percentage of the ratio of the total covered area of the building and the total land area of the site. It is calculated by dividing the covered area (plinth area) of the building by the total area of the plot and multiplying by 100. MGC is expressed as a percentage and varies depending on the occupancy type of the building, the size of the plot, and the width of the road (Clause 50.1). 01 Formula for Maximum Ground Coverage (MGC): Maximum Ground Coverage MGC for different occupancy types, different plot sizes, and different widths of the road are prescribed by the Dhaka Mohanogor Imarat (Nirman, Unnoyon, Songrokkon o Oposharon) Bidhimala, 2008. 1823012 02 Here, a section is used as an example to study the FAR and MGC rules prescribed. Maximum Ground Coverage Table 3 (ka) to 3 (cha) includes regulations on FAR and MGC 1823012 03 Here, a section is used as an example to study the FAR and MGC rules prescribed. Maximum Ground Coverage FAR and MGC according to Occupancy type: 1823012 Type A (A1-A5): Residential Houses and Hotels Type B (B1-B2): Educational Institutes Type C (C1-C4): Institutions Type D (D1-D2): Healthcare Type E (E1-E6): Assembly and Religious Establishments Type F (F1-F5): Commercial Buildings 04 Here, a section is used as an example to study the FAR and MGC rules prescribed. Maximum Ground Coverage FAR and MGC are prescribed for different Plot sizes and different widths of the road 1823012 05 Maximum Ground Coverage 1823012 Maximum Ground Coverage of 67.5% will be valid for plots under 134 sq. m. For any plot larger than 1206 sq. m., MGC will be 50%. For a plot of any size, with an adjacent road of width 18 m or more, MGC will be 50%. No part of a building can be extended outside MGC except those mentioned in Clause 46.5. 06 The spaces within a plot which shall be remained uncovered up to the sky from the formation level of the building. Mandatory Open Space A maximum of 50% of Mandatory Open Space (MOS) can be paved (Clause 46.5 Ka). Paved space can be used for Parking and Security purposes. The height of any shade in the paved space will be a maximum of 4 meters from the finished level or 3 meters from the plinth level. 1823012 07 Mandatory Open Space M OS Figure: Illustration of MOS space 1823012 08 Mandatory Open Space 4m from finished space 3m from Plinth Figure: Use of Paved space 1823012 09 Mandatory Open Space 4m from finished space 3m from Plinth Figure: Use of Paved space 1823012 10 Mandatory Open Space 1823012 50% of the MOS should be opened for rainwater absorption (Clause 46.5 Ga). Basement can’t be extended in the area of 50% of MOS. 11 THANK YOU Professional Practices BECM 4200 Presented by: Md. Sakhawat Hossain Roll - 1823009 Authority can give restriction to building height according to local jurisdiction near Building Height Airport Microwave station Telecommunication station Large water body Riverside Historical place (as per clause 52.2 & 52.3) Building Height (Cont.) Aviation obstruction lighting used To enhance the visibility of structures 45.7 m 150 ft To reduce conflict with the safe navigation of aircraft If building height more than 45.7 meter or 150 feet (as per clause 52.4) Fig: Aviation Obstruction Lighting Floor & Basement Different building floors should be named as Basement Semi-basement Ground floor First floor Second floor Roof (as per clause 53.1) Floor & Basement (Cont.) Mechanical system should be used in basement for Proper lighting Well ventilation system To keep always dry Prevention of damp in wall (as per clause 53.2.1) Upward slope should be used on entrance to prevent rain water from surface (as per clause 53.2.2) Floor & Basement (Cont.) Floor & Basement (Cont.) Should have minimum one stair connected to ground floor or ground surface from basement Stair number should be selected according to user number and distance (as per clause 53.2.3) Thank you Professional Practices BECM 4200 Presented by: Hasibur Rahman Roll - 1823014 In case of building design approval, there should be a minimum 6 meter wide road including footpath. Road and Footpath (as per clause 54.1) (Clause 54) (6m) If a road is less than 6 meters wide as per the approved design, half of the land required for widening to 6 meters shall be transferred equally on both sides. Road and Footpath (as per clause 54.2) (Clause 54) (X) The FAR, required Setback and Maximum land cover of the plot should be calculated based on the reduced land size after transfer of required portion of land for roads. Road and Footpath (as per clause 54.3) (Clause 54) (X) All new link roads should have sidewalks. Road and Footpath (Clause 54) If there is no sidewalk on the connecting road in front of the plot, the applicant shall construct and maintain it himself as per the order and procedure of the authority. (as per clause 54.8-54.9) Edge Regulations (Clause 55) In unplanned areas, the boundary of the plot located at the junction of two roads should be Circular or at a fixed distance or height from the edge. (as per clause 55.1) Edge Regulations (Clause 55) For this reason, the 1.5 m × 1.5 m area of the land at the edge should be kept empty on the ground and above and no construction can be done. (as per clause 55.2) Thank you Course No: BECM 4200 Course Title: Professional Practices Presented by: Md Ramjan Ali Roll - 1823013 Department of Building Engineering and Construction Management Parking (Clause 56.2): 0° (Parking) One way traffic with Bay on one side 3.5m One way traffic with Bay on both side 4m Two way traffic with Bay on both side 4.25 m Parking (Clause 56.2): 45° (Parking) One way traffic with Bay on one side 4.0m One way traffic with Bay on both side 4.0m Two way traffic with Bay on both side 4.25m Parking (Clause 56.2): 90° (Parking) One way traffic with Bay on one side One way traffic with Bay on both side 4.25m 4.25m Two way traffic with Bay on both side 4.25m Parking (Clause 56.3 & 56.4): 4.25m The separate entrances and exits must be at least 3 meters wide. The width requirement is 4.25 meters for buses and trucks, and 6 meters for single entrances and exits. Separate Entrance 6m Single Entrance Parking (Clause 56.5) Minimum required parking space in case of designs submitted for enlargement project or building approval: Type of Occupancy Minimum Parking Requirements Occupancy Type – “A” (Residential Building) Single house / gross area of not more than 200 square meters 1 car parking Single house / gross area of more than 200 square meters 1 car parking Multi family and gross area of more than 200 square meters 1 car parking for each unit 140 square meters < gross area < 200 square meters 2 car parking for 3 unit 90 square meters < gross area < 140 square meters 1 car parking for 2 unit 60 square meters < gross area < 90 square meters 1 car parking for 4 unit For Gross area of 60 square meters 1 car parking for 8 unit For Gross area of 90 square meters (Without Car parking area) 1 bike parking for 5 unit Hotel ( Star Classified) 1 car parking for 5 guest room Hotel ( General Classified) 1 car parking for gross area of 200 square meters Parking (Clause 56.6) For parking of up to 4 vehicles, if required, angular parking directly from the road may be provided subject to fulfillment of the following conditions: The angular parking should not exceed a 45-degree angle. Parking must be at least 15 meters away from the bus stand. Parking is prohibited within 25 meters of pedestrian crossings or intersections. Parking is not allowed on the national highway. Parking (Clause 56.8, 56.10 & 56.11) 4.25 m Ramps in parking lots should have a maximum slope of 1:8, and there should be a flat 4.25-meter section before the ramp begins. However, this rule doesn't apply if the ramp is only 0.75 meters high. 1 8 3m For one-way traffic, the minimum width is 3 meters, while for ramps accommodating two-way traffic, it should be at least 4.25 meters wide for regular vehicles. On residential sites, there should be a separate lane for merging traffic and a parking area with at least 100 spaces. On other sites, there should be a merging lane and a parking area with a minimum of 50 spaces. 4.25 m Parking (Clause 56.12 & 56.13): Ramps need a minimum 2.25 meters of height clearance, and if the land is up to 10 meters wide, only one entrance and one exit are allowed. Car lifts can replace ramps for parking. 2.25 m CLAUSE : 58 (Minimum requirements of Building Dimensions) ROLL: 1823016 Why we will follow minimum requirements of building dimension: Comfort: They give enough space for people to live or work comfortably. Public Health: Avoiding overcrowding keeps people healthy. Community Well-being: Following rules makes a nice place to live and work. Minimum requirements of Building Dimensions Bedroom Clause 58(A) Every unit should have at least one bedroom with Area of 9.5m2 Width of 2.5m Other rooms should have at least Area of 5m2 Width of 2m Minimum Bedroom height should be height 2.75m Below beam 2.13m AC room 2.44m Minimum requirements of Building Dimensions Kitchen Clause 58(B) Kitchen room should have minimum – • Area 4m2 • Width 1.5m Kitchen height should be at least 2.75m Kitchen window area should be at least 1m2 Fig: Plan of kitchen Fig: Section of kitchen Minimum requirements of Building Dimensions Bathroom Clause 58(C) Bathroom including water closet & bath place– • Minimum Area 2.75m2 • Minimum Width 1m Bathroom including water closet & Toilet – • Minimum Area 1.2m2 • Minimum Width 1m Toilet with bath place & basin should have – • Minimum 1.5m2 • Minimum Width 1m Floor Area Minimum requirements of Building Dimensions Bathroom Clause 58(C) Toilet with water closet & bath place should have – • Minimum Floor Area 2.5m2 • Minimum Width 1m Minimum bathroom height should be at least 2.13m Bathroom should have at least 0.37m2 window area Minimum requirements of Building Dimensions Stair Clause 58(D) Building Type I. II. Minimum Stair Width(m) Residential i. Single Family Home ii. Apartment & Flat houses iii. Mess, Hostel iv. Low-class house v. Residential Hotel 1.0 1.15 1.25 *** 1.25 Educational Institutions 1.50 III. Institutional 1.50 IV. Health Care 2.00 V. 2.00 Assemblies width of stair Minimum requirements of Building Dimensions Stair Clause 58(D) Building Type VI. Commercial Building i. Office ii. Small Shop and Market iii. Big Shop and Other iv. Daily Essential Services in Market VII. Other Minimum Stair Width(m) 1.50 1.50 2.00 1.50 1.25 width of stair Minimum requirements of Building Dimensions Stair Clause 58(D) 225mm Tread < Summation of Riser and Tread should be 400mm • Riser 175mm • Tread 225mm Max. no. of Steps 20 Height of Head Room 2.15m Landing_ width of stair < Tread + Riser_ 400 mm Half Landing Rise r Fig: Height of headroom Fig: Section of stair _< 175mm Thank you Professional Practices BECM 4200 Presented by: Dipayan Biswas Roll - 1823018 Fire Exit Exit access Exit Exit discharge Means of Escape: A safe route provided for people to travel from any location in a building to a place of safety without need of outside assistance. (Clause 59.01.01) General Needs Ramps must be used if level of the exit changes more than 300mm. (Clause 59.02.04) Ramp General Needs (cont.) Exterior doors that are not used by people with disabilities or the elder, can be stepped down to a maximum of 200mm. (Clause 59.02.04) Highest Stepdown – 200mm Exit sign General Needs (cont.) Direction of the exit should be clearly visible and illuminated. (Clause 59.02.05) Location of the Exit Should not pass through locked area. (Clause 59.03) Location of the Exit (cont.) All the Exits should be placed in a way that ensures Continuous, Uninterrupted Means of Escape (Clause 59.03.04) Occupant load for various occupancies Required Width of the Exit Per Occupant Corridors & Passages Obstacle free and dead end length not more than 10 m. 2.4m Minimum clear height of corridor or passageways not less than 2.4 m (Clause 59.06) Not more than 10m Fire resistance rating : For exit access corridor- minimum 1 hour For door to reach at exit access – minimum 1/2 hour (Clause 59.06) Occupancy Maximum Occupant Load Maximum Travel Distance ( m) A Residential C Institutional D Health Care 12 23 B Educational E Assembly F Business and Marcentile G Industrial 50 23 H Storage 30 5 30 8 Exit Door Distance for spaces with 1 exit door presented in the table. If more than this table, 2 exit doors required J Hazardous (Clause 59.08) Exit Door (cont.) Minimum width of exit door is 1m and height 2m Exit access doors will be side swing type and opening towards travelling side only 0.9 m free space after swinging Sliding or hanging exit door is forbidden Exit door will not open at stair flight (Clause 59.08) 1m 2m Thank you Professional Practices BECM 4200 Presented by: Soeb Hasan Roll - 1823015 (Clause 59.09) Stair Minimum width for landing can’t be less than stair width For straight run stair, initial landing 1.2 m Spiral Stair (Clause 59.09.03) Only inside residential building Requirements: Minimum Width 650 mm Tread Depth 250 mm Riser 225-215 mm Ramp Ramp slope (Clause 59.10) < 1:12 If ramp slope > 1:15 Hand rail must be provided at both sides Materials must be non-slippery Horizontal exit (Clause 59.11) Requirements: Minimum Width 1m If it is Inclined then slope must be 1:12 without any tread Door must be opened at outside direction Except stair, shaft etc. Shelter area should be Usual For health center 0.28 sqm per person 2.8 sqm per bed (Clause 59.12) Number of exit Requirements: Building Type (Maximum Storied) Distance (m) Users Number Users Number of Exit 4 Storied Residential 23 12 people 1-500 2 10 Storied Residential 23 4 Unit at a floor 501-1000 3 2 storied Other Building 23 50 people 1001-continue 4 1 storied Storage 30 30 people 1 Storied Hazardous & Dangerous Building 8 5 people Passage Length (Clause 59.13) Requirements: Users must find an exit from anywhere of the building Building Type Maximum Distance (m) Residential, Educational, Organizations, Health Center, Religious 25 Commercial, Storage 30 Industry 45 Thank you Universal Accessibility Presented by Niaj Morshed Roll: 1823017 General Rules Minimum rotational area. 1500 mm x 1500 mm Minimum access and corridor requirements. Vertical spacing. 1200 mm Floor materials. 100 mm Use of bevel and ramp. 680 mm 2m 300 mm Door Minimum width. 800 mm 1500 mm x 1500 mm Door spacing. 1200 mm x 1200 mm 600 mm Door handle height. Appearance. 850 to 900 mm Railing and Stair Minimum diameter of railing and free space from attached wall. 38 to 50 mm 800 to 900 mm Railing height. Minimum tread and riser size. Tread Nosing size. 125 to 175 mm Railing requirements. Texture and visibility. 280 mm 1200 mm Ramp Ramp ratio (1:12). Ramp length. 12 m Ramp width. Landing. 1.5 m x 1.5 m 1.5 m x 1.5 m Lift Lift lobby requirements. 1.5 m x 1.5 m 800 mm Command switches height. Lift door width. 890 to 1200 mm Lift cabin size. Platform lifting. 1500 mm x 1200 mm 900 mm x 1200 mm 1.5 m x 1.5 m Washroom and Toilet Toilet ratio for differently abled persons. Spacing. 800 mm Railing requirements. Tap and basin requirements. Shower space. > 850 mm Parking and Seating Dedicated parking space for differently abled persons. 3.2 m Parking space width. Dedicated seating space for differently abled persons. Seating space requirements. Thank you