TESTS UNDERTAKEN AND REPORT PREPARED BY
CSA GROUP TESTING UK LIMITED
Opinions and interpretations expressed herein
are outside the scope of UKAS Accreditation
Author:
A Randle
Laboratory Technician
Technical Approval:
S Cork
Laboratory Manager
Date:
2nd April 2020
Ingress Protection test on a
SFS Series Scotch and Yoke Pneumatic Actuator
on behalf of Amahas Engineering SDN BHD
Report No: N80025828A
Commercially in Confidence
Copyright  CSA Group Testing UK Ltd
The contents of this document are subject to the terms
and conditions of CSA Group Testing UK Ltd available
free on request.
Form 6154, Issue 18
Page 1 of 7
CSA Group T esti ng UK Ltd - Regi stered i n Engl and and Wal es: No 2888007
Regi stered Offi ce: Hawarden Industri al Park, Hawarden, CH5 3US Uni ted Ki ngdom
Accredi ted certi fi cati on and EU Noti fi ed Body acti vi ti es are undertaken by Si ra Certi fi cati on Servi ce
CONTENTS
Section
Title
Page
1
Introduction
3
2
Description of test sample
4
3
Tests for first characteristic numeral
6
4
Tests for second characteristic numeral
7
5
Conclusion
7
Page 2 of 7
N80025828A
Form 6154, Issue 18
UNIT6, HAWARDEN INDUSTRIAL PARK
HAWARDEN, CH5 3US. UNITED KINGDOM
TELEPHONE: 01244 670900
0327
TEST REPORT
ISSUED BY CSA GROUP TESTING UK LIMITED
Carried out by CSA Group Testing UK Ltd on behalf of:
Amahas Engineering SDN BHD
Lot 15916, KG. Gelugor
Kerteh
24300 Kemaman
Terengganu
Malaysia
Project No: 80025828
Commercially in confidence
1
INTRODUCTION
This report refers to the performance of the test sample when tested against the agreed
programme. It does not imply that any other samples or products necessarily comply with the
requirements of the test programme. In addition, whilst this report maybe freely reproduced as
a complete document it may not be abstracted.
Manufacturer:
Amahas Engineering SDN BHD
Type Identification:
SFS Series Scotch and Yoke Actuator
Serial number:
Given identifier 80025828 Sample #2 by CSA Group
Standard:
IEC 60529:2013
Deviations from Standard:
None
Aim:
IP66
CSA Test Procedure:
LOP 220
CSA Internal Test Report:
19/0353
Sample Delivery Date:
6th February 2020
Tests Conducted Between:
20th to 25th March 2020
Page 3 of 7
N80025828A
Form 6154, Issue 18
2
DESCRIPTION OF TEST SAMPLE
The sample consisted of two compartments, the scotch and yoke compartment (highlighted by
the black box) and a power module (highlighted by the yellow box)
Locations where O-rings were located
Figure 1 – Typical views of sample
Page 4 of 7
N80025828A
Form 6154, Issue 18
Locations where O-rings were located
Figure 2 – typical view of Scotch and Yoke compartment
Figure 3 – Typical view of power module
Page 5 of 7
N80025828A
Form 6154, Issue 18
2.1
Materials of construction
The primary material of construction of the scotch and yoke pneumatic actuator was
metallic (carbon steel).
2.2
Dimensions
The approximate dimensions of the scotch and yoke compartment were 100 x 120 mm
(h x diameter)
The approximate dimensions of the power module compartment were 140 x 150 mm (h
x diameter)
2.3
Seals
An O-ring was located between the scotch and yoke compartment lid and the enclosure.
Two additional O-rings were located inside of the scotch and yoke compartment, see
Figure 2 for details. An O-ring was located under each of the air inlet and air exhaust
stopping plugs. Silicone grease was applied by the customer in both compartments, see
Figures 2 and 3 for details.
2.4
Fasteners
The scotch and yoke lid was secured to the enclosure using 8 fixing bolts. The power
module cover was secured using 6 fixing bolts.
For the IPX6 test, the sample was tested as supplied. For the IP6X test, all fixing bolts
were secured tool tight at the request of the engineer.
3
TESTS FOR FIRST CHARACTERISTIC NUMERAL: 6
3.1
Test for protection against access to hazardous parts
Reference IEC 60529:2013 clause 12.
A rigid test wire Ø 1 mm and length to a stop face of 100 mm was pushed against all
openings of the test sample with a force of 1 N ± 10%.
3.1.1 Result
The test wire did not come into contact with any hazardous parts.
3.2
Test for protection against solid foreign objects
Reference IEC 60529:2013 clause 13.
The test sample was supported inside a chamber containing approximately 2 kg of test
dust per m3, with maximum particle size 75 µm maintained in suspension. As required
by the standard a connection was made to a vacuum pump to maintain an underpressure inside the test sample which did not exceed 20 mbar. A 6 mm tube was
secured to both the power module compartment and the scotch and yoke compartment,
with both compartments tested simultaneously.
No extraction rate was recorded, therefore the test duration was 8 hours.
3.2.1 Result
On internal inspection of the test sample no dust was found. Both the power module and
the scotch and yoke compartments were inspection for ingress.
Page 6 of 7
N80025828A
Form 6154, Issue 18
4
TEST FOR SECOND CHARACTERISTIC NUMERAL: 6
4.1
Test for protection against water
Reference IEC 60529:2013 clause 14.
The test sample was supported in its normal operating orientation. Water from a
standard water jet hose test nozzle with internal ∅ 12.5 mm was directed at the test
sample from all practicable directions at a rate of 100 L/min from a distance between
2.5 to 3 metres. The test duration was 3 minutes.
4.1.1 Result
On internal inspection of the test sample no water was found. Both the power module
and the scotch and yoke compartments were inspection for ingress.
5
CONCLUSION
The test sample described in sections 1 and 2, when tested in the manner described in
sections 3 and 4, satisfied the requirements of IEC 60529:2013, IP Code 66.
--- End of Test Report ---